13-Form 25 Cement Preference Certification.pdf

PDF 104 KB Posted

Attached to
Southwest 96-inch Water Transmission Pipeline Project
Solicitation number
CIZ-DWU-26 003
Issued by
Dallas County, Texas

About this file

This is a Cement Preference Certification form required for the Southwest 96-inch Water Transmission Pipeline Project in Texas. The form mandates that bidders certify their concrete products utilize Portland cement from vendors complying with all applicable state and federal environmental standards, specifically Texas Commission on Environmental Quality (TCEQ) and EPA regulations regarding nitrogen oxide (NOx) emissions. Bidders must demonstrate that cement vendors operate kilns with emissions exceeding the NOx standards established in 30 Texas Administrative Code 117.3110(a)(1)-(4) by specific percentage reductions: 10 percent lower for long wet kilns, 20 percent lower for long dry kilns, 20 percent lower for preheater kilns, and 35 percent lower for preheater-precalciner or precalciner kilns. As of March 9, 2011, the specific NOx emission limits are 3.6 lbs per ton of clinker for wet kilns, 4.1 lbs per ton for dry kilns, 3.0 lbs per ton for preheater kilns, and 1.8 lbs per ton for preheater-precalciner or precalciner kilns.

The certification form requires the bidder's authorized officer to sign and have the document notarized by a Texas Notary Public. This cement preference requirement represents a salient environmental procurement criterion for the project, establishing a preference for concrete products manufactured using cleaner Portland cement production processes. The form establishes compliance verification mechanisms that ensure bidders meet stricter-than-minimum environmental standards for cement production, supporting Texas's air quality objectives while maintaining project specifications for the water transmission pipeline construction.

View the file

Other files

File Type Posted
14-DWU-FRM-170-CS Request For Competitive Sealed Proposals 26 003.pdf PDF
6-BEH-FRM-607.SAW SBE Good Faith Effort Documentation Form.docx DOCX document
23-Table 3 Subcontractors and Suppliers.pdf PDF
43-Table 10 Proposed Project Quality Control Managers.docx DOCX document
28-Table 8 Proposed Project Superintendents.pdf PDF
12-Conflict of Interest Questionnaire.pdf PDF
3-BEH-FRM-610.SAW SBE Subcontractor Intent Form.docx DOCX document
48-26 003 Bid Proposal Spreadsheet.xlsx XLSX spreadsheet
32-Table 12 Financial Information.pdf PDF
9-Sample Contract for Services.pdf PDF
7-BEH-FRM-604.SAW Local Participation Workforce Impact.docx DOCX document
10-BIDDERS AFFIDAVIT.pdf PDF
25-Table 5 Demonstation of Budget Performance.pdf PDF
40-Table 7 Proposed Project Managers.docx DOCX document
44-Table 11 Project Information for Key Personnel.docx DOCX document
11-Acknowledgement of Addendum.docx DOCX document
15-TWDB-0459.pdf PDF
21-Table 1 General Information.pdf PDF
24-Table 4 Current Projects and Projects Completed.pdf PDF
47-Table 13 Affidavits.docx DOCX document
36-Table 3 Subcontractors and Suppliers.docx DOCX document
37-Table 4 Current Projects and Projects Completed.docx DOCX document
27-Table 7 Proposed Project Managers.pdf PDF
42-Table 9 Proposed Project Safety Managers.docx DOCX document
34-Table 1 General Information.docx DOCX document
1-DRIVE Policy.pdf PDF
49-Volume I - Specifications - SWPL.pdf PDF
29-Table 9 Proposed Project Safety Managers.pdf PDF
19-26-003 SWP Summit GST to Hwy 67 Bid Set Specs Vol 5.pdf PDF
39-Table 6 Demonstration of On-Time Performance.docx DOCX document
20-26-003 SWPL Summit GST to Hwy 67 BID SET FULL BW.pdf PDF
26-Table 6 Demonstration of On-Time Performance.pdf PDF
46-Table 12 Financial Information.docx DOCX document
30-Table 10 Proposed Project Quality Control Managers.pdf PDF
17-26-003 SWP Summit GST to Hwy 67+Bid Set Specs Vol 3.pdf PDF
16-26-003 SWP Summit GST to Hwy 67 Bid Set Specs Vol 2.pdf PDF
45-Table 11 B Project Information for Key Personnel.docx DOCX document
35-Table 2 A B Contractors Approach.docx DOCX document
4-BEH-FRM-605.SAW SBE Utilization Plan Commitment to Local Eco Impact.docx DOCX document
38-Table 5 Demonstation of Budget Performance.docx DOCX document
2-BEH-FRM-602.SAW SBE Affidavit.docx DOCX document
33-Table 13 Affidavits.pdf PDF
22-Table 2 A B Contractors Approach.pdf PDF
5-BEH-FRM-606.SAW Engagement Score Past Commitment Form.docx DOCX document
8-BEH-FRM-609.SAW Prime Self Performance Declaration.docx DOCX document
18-26-003 SWP Summit GST to Hwy 67 Bid Set Specs Vol 4.pdf PDF
31-Table 11 Project Information for Key Personnel.pdf PDF
41-Table 8 Proposed Project Superintendents.docx DOCX document
Show all 48

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FORM 25

CEMENT PREFERENCE CERTIFICATION

I, ________________________, the _________________ [state title of officer of company] of _____________________________________ [legal name of bidder company], do hereby certify that my bid for concrete products utilizes Portland cement produced by vendors who:

(1) are in compliance with all applicable state and federal environmental standards relating to the emission of NOx, including all applicable TCEQ and EPA rules and regulations; and

(2) operate kilns with emissions that exceed the standards for NOx emissions set out in 30 Tex. Admin.

Code § 117.3110(a)(1)-(4) (as provided presently and as may be amended in the future) by the following percentage amounts:

(a) for each long wet kiln, 10 percent lower than the standard for long wet kilns located in Ellis

County, Texas as set out in 30 Tex. Admin. Code § 117.310(a)(1)(B) [As of 3-9-11, wet kiln NOx emissions can NOT exceed 3.6 lbs per ton of clinker produced.];

(b) for each long dry kiln, 20 percent lower than the standard for long dry kilns located in Ellis

County, Texas, as set out in 30 Texas. Admin. Code § 117.3110(a)(2) [As of 3-9-11, dry kiln NOx emissions can NOT exceed 4.1 lbs per ton of clinker produced.];

(c) for each preheater kiln, 20 percent lower than the standard for preheater kilns located in

Ellis County, Texas, as set out in 30 Tex. Admin. Code § 117.3110(a)(3) [As of 3-9-11, preheater kiln NOx emissions can NOT exceed 3.0 lbs per ton of clinker produced.];

and

(d) for each preheater-precalciner or precalciner kiln, 35 percent lower than the standard for preheater-precalciner and precalciner kilns located in Ellis County, Texas, as set out in 30 Tex. Admin. Code § 117.3110(a)(4) [As of 3-9-11, preheater-precalciner or precalciner kiln NOx emissions can NOT exceed 1.8 lbs per ton of clinker produced.].

BIDDER:

Print Name and Title

SUBSCRIBED and SWORN TO before me this ____ day of __________, 20___.

[Seal] Notary Public, State of Texas

My commission expires: ______________

Cement Preference Certification

File details come from the government source that posted it. Updated .