08541 Vinyl Windows.pdf

PDF 177 KB Posted

Attached to
Renovate 20 Apartments in Parkridge - Phase 2
Solicitation number
US.245854
Issued by
Northampton County, Pennsylvania

About this file

This is a specification document for vinyl windows related to the Bethlehem Housing Authority's renovation project for 20 apartments at the Parkridge family development in Pennsylvania. The document appears to contain detailed specifications and technical requirements for the vinyl window products to be installed as part of Phase 2 of the apartment renovation initiative. Sealed bids were due electronically on the PennBid site by Thursday, October 22, 2026 at 11:00 AM, with bids to be electronically opened at that time. A bid bond equal to 10% of the bid amount, secured by a surety company listed in the Department of Treasury Circular #570, was required to accompany each bid submission. The successful contractor was required to furnish and pay for satisfactory Performance and Payment Bonds. Contract documents, including specifications and drawings, were available on the PennBid website, with questions directed to Scott Speshok at 610-483-0322.

The specification document establishes the technical and performance standards for the vinyl windows to be procured and installed as part of the apartment renovation work. The Bethlehem Housing Authority reserved the right to reject any or all bids or to waive any informalities or irregularities in the bidding process. Additional project information was available at www.Bethlehemhousing.org. No specific set-asides, incumbents, or funding sources were identified in the available contract documentation.

View the file

Other files

File Type Posted
02900 Landscaping.pdf PDF
16200 Electrical.pdf PDF
2-Parkridge PH 2 wage rates.pdf PDF
09670 Vinyl Composition Tile.pdf PDF
01010 General Work Requirements.pdf PDF
7-Parkridge PH 2 Addendum.pdf PDF
9-Bid table for Parkridge Phase 2.pdf PDF
06100 Rough Carpentry.pdf PDF
02210 Selective Demolition.pdf PDF
5-Parkridge PH2 IFB.pdf PDF
1-Parkridge documents to be submitted.pdf PDF
06650 Solid Polymer Fabrication.pdf PDF
15400 Plumbing.pdf PDF
05500 Metal Fabrications.pdf PDF
06240 Plastic Laminate.pdf PDF
08110 Storm Doors.pdf PDF
08200 Flush Wood Doors and Frames.pdf PDF
07920 Sealants and Caulking.pdf PDF
01700 Project Close-out.pdf PDF
10300 Vinyl Coated Shelves.pdf PDF
3-Parkridge Ren. PH 2 Admin. Specs.pdf PDF
01545 Contractor Use of Premesis.pdf PDF
01500 Construction Facilities.pdf PDF
08100 Metal Doors and Frames.pdf PDF
6-Parkridge PH 2 Ren. Drawings.pdf PDF
09260 Gypsum Wallboard.pdf PDF
09650 Resilient Sheet Flooring.pdf PDF
8-Parkridge PH 2 Addendum 2.pdf PDF
09900 Painting.pdf PDF
0 Table of Contents.pdf PDF
01710 Cleaning.pdf PDF
01620 Storage and Protection.pdf PDF
12390 Kitchen Cabinetry.pdf PDF
06200 Finish Carpentry.pdf PDF
16000 Basic Electrical Requirements.pdf PDF
10260 Fiberglass Wall Panels.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 08541

VINYL DOUBLE HUNG WINDOWS

PART 1 - GENERAL

1.1 SUMMARY

A. This section include removal of existing windows and replacement with vinyl windows, including hardware, glazing, and miscellaneous trim to install windows indicated.

1.2 SUBMITTALS

A. Comply with pertinent provisions of Section 01340.

B. Product data: Provide:

1. Manufacturer's data, catalog cuts, dimensioned drawings, and other data needed to prove compliance with the specified requirements and to enable proper preparation of the roof opening.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Minimum ten (10) years producing vinyl (PVC) windows.

B. Installer Qualifications: Utilize an installer having a minimum of five (5) years experience on projects of similar size.

C. Source Limitations: Obtain window units from one manufacturer through a single source.

D. Provide Vinyl Windows Compliance with requirements indicted in AAMA/WDMA/CSA/1.S.2/A440-11 for operating force, air infiltration, water penetration, and structural performance grade of window units required.

E. Energy Performance: all units will comply with the current “Energy Star” requirements.

08541 - 1

1.4 DELIVERY, STORAGE AND HANDLING

A. Windows are to be fully plastic wrap packaged to provide protection from normal shipping and handling practices.

B. Windows are to be stored inside a clean, well-drained, well ventilated area free of dust and corrosive fumes. Windows must not be stored above 120ºF.

C. Windows are to be stacked vertically on edge so that water cannot accumulate on or within materials.

D. Windows may not be stored in direct sunlight when covered with plastic wrapping.

1.5 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer’s absolute limits.

1.6 WARRANTY

A. All frames, sashes, hardware, screens, balances and glass are warranted from manufacturing defects in material and workmanship for 20 years from date of manufacturing.

B. The warranty period for commercial project work such as apartments, housing authorities and other buildings not used by individual home owners is 10 years, covering all vinyl and component parts. Consult window manufacturer warranty for complete details.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Provide Vinyl Double Hung Window with a solid White color finish on interior & exterior.

B. Acceptable products:

1. This specification is based on the 440 Series Sloped Sill, Tilt Double Hung Window as manufactured by Interstate Building Materials, Inc., (570) 655- 2811, (800)338-9997, Fax: (570)655-3422, sales@interstatebldg.com or owner approved equal.

08541 - 2 mailto:sales@interstatebldg.com

A. Products:

1. Vinyl replacement/new construction windows shall be INTERSTATE 440/6800 double hung window as manufactured by INTERSTATE Building Materials, Inc., Pittston Twp., PA.

B. Testing:

1. Windows shall be structurally tested and certified by independent testing laboratories and meet or surpass AAMA/NWWDA 101/I.S.2 grade HC-55 performance requirements. Test results shall be from a window with a minimum size of 56”W x 91”H. Air infiltration shall not exceed 0.05 cfm/ft at 25 mph.

1. The window shall have a U value not greater than 0.26 and an R-value not less than 3.85, SHGC (Solar Heat Gain Coefficient) not to exceed .30 and VT (Visible Light Transmittance) not to exceed 0.54, tested in accordance with NFRC 100-97 & 200.

2. Windows have been thermally tested to National Fenestration Rating Council NFRC 100-97 & 200 test methods based on the window unit (not center of glass), and residential values, and are certified by independent testing laboratories to meet or exceed the architect’s choice of the glass options shown below:

3. Window manufacturer shall certify that windows are US Department of Energy; Energy Star qualified with optional RLE 70/36 Low E/argon gas filled insulated glass.

08541 - 3

.48 .54 .27 .30 .26

Low E/Argon

Double Hung

VT Grids VT SHGC Grids SHGC U-Value Glass Options Series

Materials:

4. Vinyl Extrusions: Window extrusions shall be extruded from high quality, weatherable, high impact PVC extrusions and shall confirm to AAMA/NWWDA 101/I.S.2-97. Extrusions for all window styles utilized on the project shall have a similar beveled exterior profile and or integral J-channel brickmold on new construction. White and Clay colors are integral to the resin and uniform throughout the extrusion. All external wall thicknesses are to be minimum .062+/-.010 for the main frame and .062+/-.010 for the sash.

5. Fasteners are to be stainless; cadmium plated or zinc plated steel.

6. Hardware:

a. Tilt latches are to be acetal, nylon, PVC, or polycarbonate wit stainless steel springs. Tilt latches are to be completely housed within the window sash members; only the thumb latch mechanism is to be raised externally above the sash to allow for easy operation of the tilt-latch mechanism.

b. Sash Lift Rail: Sash is to have extruded integral finger lift rail of .070+/-.010 thickness traveling the approximate glass width of the sash. Lift rail is to project at least 1/2” from the sash frame main body for easy raising and lowering of the sash.

7. Window locks: are to be cam action positive locks, made of Composite material, with solid color finish to match the window color and shall be fastened to sash with stainless fasteners penetrating non-conductive re-enforcement. Keepers are to be face mounted on the top sash rail with fasteners penetrating an internal aluminum re-enforcement and attached in such a way as not to eliminate continuous interlock.

8. Balances are to be INTERSTATE “Light Lift®” SP type coil balance, 301 high yield stainless type with no tensioning required and allow for a uniform load throughout sash travel. Balance cases are to be molded from acetal for its superior lubricous qualities. The coil balance system is to be comprised of the following: i) one or more 2-piece acetal housings which encase the stainless steel coils; ii) 301 high yield stainless steel coil springs with sufficient strength to hold the sash stationary in any position; iii) stamped aluminum mounting bracket to affix the coils to the window jamb frame; iv) balances are to be mounted in such a way that the fabricated end of the coil is attached to the balance shoe which travels with the sash. The sash is engaged into the shoe with a cast pivot bar designed to interlock into the shoe when in the vertical position to aid in structural support.

08541 – 4

9. Balance shoes are to be constructed of molded nylon 6/6 type 6601-L lubricating nylon type with zinc plated, cadmium plated or stainless steel balance hooks and tilt pins.

10. Jamb adjuster screws, shall be cadmium, zinc plated, or stainless steel.

11. Balance plugs are to be installed in the bottom sash tracks, above each balance housing and are to be designed to tightly fit within the window jamb balance track frame. Balance plugs are to be made of a 1” thick high density felt and are to move vertically within the window jamb frame together with the window sash movement. Balance plugs are to be long lasting and prevent the excessive passage of air from the window jamb balance track into the building.

12. Weatherstrip - All windows are to be double weatherstripped at all areas finseal/pile construction of polypropylene and conforming to AAMA 701.2 standards. Meeting rail is to be double weatherstripped.

13. Insect screens shall be standard charcoal colored fiberglass.

B. Construction:

1. Structural Members:

a. Reinforcing members, made of super thermal efficient non-conductive material with variable wall thickness (depending on profiles), which range from .0125” to 0.184” for the lock rail, keeper rail, lift handle and sash styles shall be used. Reinforcements shall have no adverse effect on overall thermal performance.

b. Frames of multiple units are to incorporate a continuous head and sill with a structural Tee Mullion. Optional structural mull system utilizes a snap-in rigid PVC extrusions, which mounts flush and locks into integral mulling grooves on main frame. A super thermal efficient non-conductive material will be anchored between the mulled units to achieve higher design pressure rating without sacrificing thermal values. Main frame jamb width is to be 3 ¼”.

c. Sill is a slope design with triple weather seals and no weep hole requirements which aid in maintaining air infiltration values 80% lower than industry standards. A patented Storm Interlock design, engages the sash

08541 - 5 handle rail with the sill. This, along with the Telescoping Dam leg design which penetrates into the jamb profiles, were designed to increase design pressure performance both from a wind load and water penetration testing.

C. Fabrication:

1 All frame and sash members are to be mitered and thermal fusion welded for strength and durability. All welds are to be mechanically de-flashed for a consistent smooth attractive appearance. Frames and sashes are to have elongated integral weep holes.

2. All mechanical fasteners are to be installed in a structurally sound fashion so as to present a smooth clean appearance and are concealed wherever possible.

3. Glass is to be held in place by PVC snap-in glazing beads which are to be located on exterior of sash, and is to be wet glazed to the vinyl sash with Novaflex brand or equal silicone sealant.

D. Glass and Glazing:

1. Glass and glazing: Windows are all factory glazed with sealed insulated glass. Both upper and lower sashes for the kitchen window and the 2 living room windows shall be tempered glass.

2.Glass installed in the window units meet Federal Specification - FS-DD-G- 451D and is of glazing quality.

3.Safety glazings meet requirements of CPSC-16CFR-1201 and ANSI Z97.1.

Insulating glass units are to be assembled with TruSeal’s Duralite®,” an insulating glass edge seal system constructed using a unique Composite Laminating Technology. Duralite is preassembled with proven components, sealant, spacer and desiccant to create a high-performance durable spacer system.

Certification Standards

> EN-1279:2002 Parts 2, 3, 4, Part 6 B & C

> ASTM E2190

> ASTM E774 level CBA

> CGSB 12.8-97

> GOST 24866-99

PART 3 - EXECUTION

3.1 EXAMINATION

08541 - 6

A. Contractor to verify rough opening size is of sufficient size to receive window unit and complies with manufacturer’s requirements for opening clearances.

B. Vinyl Windows:

a. Verify that sill plate is level.

b. Notify the Owner of unacceptable conditions before proceeding with installation.

3.2 INSTALLATION

A. Preparation: All rough openings shall be dimensionally square, plumb, level, clean and provide a solid anchoring surface in accordance with INTERSTATE installation instructions, Installation Masters install procedures and drawing details.

B. Windows shall be installed only by skilled tradesmen in accordance with the manufacturer’s instructions and shop drawings.

C. Windows shall be sealed around the head, sill and side frame members in a weathertight fashion in accordance with the manufacturer’s instructions. Sealant shall have a dynamic movement capability of at least +/-50% and an outdoor weathering life of 10 years or more. Sealant is to be NovaFlex M100 brand, or equal, that is compatible with and adheres to vinyl framing and existing materials.

3.3 ADJUSTING

A. Adjust operating sashes, screen, hardware and accessories for a tight fit at contact points and weather stripping for smooth operation and weathertight closure. Lubricate moving parts.

B. Adjust sash locks and screens for smooth operation.

3.4 CLEANING

A. Clean exposed surfaces and glass immediately after installing windows.

Remove nonpermanent labels and clean surfaces.

END OF SECTION