This file is a technical specification for plastic laminate installation prepared for the Bethlehem Housing Authority's apartment renovation project at Parkridge in Pennsylvania. The specification details requirements for providing and installing plastic laminate materials in kitchen areas of 20 apartments undergoing renovation in Phase 2. Acceptable manufacturers include Panolam/Nevarmar, Wilsonart, or Owner-approved equivalents, with materials specified as solid color, smooth finish, general purpose type plastic laminate at 0.050" thick, complying with NEMA LD-3 standards. Installation requirements include preparation of substrate following new gypsum wallboard installation, placement at kitchen counter-top backsplash and side splashes, use of rigid set (urea-resin) or semi-rigid set (PVC acetate) adhesives only, and extension of laminate material a minimum of 4 inches beyond cabinet bottoms and counter-top backsplash tops. Sealed bids are due electronically on PennBid by Thursday, October 22, 2026 at 11:00 AM, with a bid bond of 10% required at submission and performance and payment bonds required upon award.
The specification requires manufacturers to submit product data and material lists within 15 days of contract award, provide a 2' x 2' sample for Owner approval, and supply matching stainless steel trim channels and accessories. Corners must be miter cut with filed edges to eliminate sharp edges, and light switch and outlet cutouts must feature radiused corners to avoid stress cracking. Installation must strictly follow manufacturer recommendations as approved by the Owner, with completion prior to kitchen cabinet and counter-top installation. Post-installation cleanup is required using only manufacturer-recommended cleaning agents, and all in-place finish work must be protected from damage until building possession transfer to the Owner. The Bethlehem Housing Authority reserves the right to reject any or all bids and waive any informalities or irregularities. Additional project information is available at www.Bethlehemhousing.org, with questions directed to Scott Speshok at 610-483-0322.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 06240
PLASTIC LAMINATE
SUMMARY:
Provide laminate plastic where shown on the contract drawings, as specified herein, and as required for complete and proper installation.
Documents affecting work of this section include, but are not limited to, General Conditions, Supplementary Conditions, Drawings, and these Technical Specifications.
QUALITY ASSURANCE:
Use an adequate number of skilled workmen who are thoroughly trained and experienced in the necessary crafts and who are completely familiar with the specified requirements and methods needed for proper performance of the work of this Section.
SUBMITTALS:
Comply with the pertinent provisions of the General requirements.
Submit product data within 15 days of award of contract to the contractor.
Submit product data and material list of items to be provided under this Section. Supply sufficient technical data to demonstrate compliance with the specified requirements.
Manufacturers recommended installation procedures which, when approved by the Owner, will become the basis for accepting or rejecting actual installation procedures used on the work.
Provide 2’ x 2’ sample of material for Owner approval.
DELIVERY, STORAGE AND HANDLING:
Comply with the pertinent provisions of the General Requirements.
06240-1
PRODUCTS:
Acceptable Manufacturers:
1.) Panolam/Nevarmar, 2 Corporate Drive, Suite 946, Shelton, CT 06484
2.) Wilsonart, 2501 Wilsonart Drive, P.O. Box 6110, Temple, Texas 76503
3.) Owner Approved Equal.
Provide solid colors, smooth finish, as selected by the Owner from list of standard colors and finishes of the approved manufacturer.
Provide general purpose type plastic laminate, 0.050” thick, complying with NEMA LD-3.
For installation use only, “rigid set” (urea-resin) or “semi rigid set” (PVC acetate) adhesives. Do not use so-called “contact adhesives”.
EXECUTION:
Examine the areas and conditions under which work of this Section will be performed.
Correct conditions detrimental to timely and proper condition of the work. Do not proceed until unsatisfactory conditions are corrected.
Following installation of new gypsum wallboard, properly prepare substrate for installation of new plastic laminate at kitchen counter-top backsplash and side splashes.
Install approved plastic laminate material in strict accordance with the manufacturer’s recommendations as approved by the Owner.
Provide matching stainless J-channel, T-channel, corner and end trim, and all other material and accessories necessary for a complete and proper installation. Corners shall be miter cut and outside edge filed to eliminate any sharp edges.
Install laminate material prior to kitchen cabinet and counter-top installation. Extend plastic laminate material a minimum of 4 inches beyond the bottom of kitchen cabinets and top of kitchen counter-top backsplash.
To avoid stress cracking, light switch and outlet cut outs shall have radiused corners.
06240-2
Properly clean all newly installed material following installation. Clean exposed areas of material free from pencil marks, adhesive material, dust, dirt and all other foreign material. Use only cleaning agents as recommended by the manufacturer of the material installed.
Following clean-up, properly protect all in-place finish work from damage until possession of the building is signed back over to the Owner.