05500 Metal Fabrications.pdf

PDF 109 KB Posted

Attached to
Renovate 20 Apartments in Parkridge - Phase 2
Solicitation number
US.245854
Issued by
Northampton County, Pennsylvania

About this file

This is a technical specification document for Metal Fabrication (Section 05500) prepared for the Bethlehem Housing Authority's Parkridge apartment renovation project in Pennsylvania. The specification outlines requirements for miscellaneous metal work to be performed during the renovation of 20 apartments at the Parkridge family development. Key deliverables include a stainless steel backsplash behind kitchen ranges fabricated from 20-gauge stainless steel with a number 4 brush finish, with edges finished using matching trim caps and J-channel. The backsplash must extend a minimum of 2 inches past the bottom edge of range hoods and a minimum of 4 inches below the top of the range. Contractors must submit product data and material lists within 15 days of contract award, along with detailed shop drawings demonstrating fabrication, installation, anchorage, and interface with other trades. Sealed bids are due electronically through PennBid by Thursday, October 22, 2026 at 11:00 AM, with contract documents available on the pennbid.net website.

The specification mandates strict compliance with American Welding Society standards and requires use of skilled, experienced workmen. Materials must conform to specified ASTM standards for various steel types, stainless steel (AISI Type 302 or 304), galvanized steel, iron castings, and fasteners. All exposed materials must be free from surface blemishes, pitting, and visible imperfections. Shop painting requirements include primers such as Tnemec 10-99 or Rustoleum Number 5769, with high zinc-dust content paint for galvanizing repairs. Installation must be performed with accurate angles and true surfaces, with exposed welds ground smooth and flush. A 10% bid bond secured by a Treasury Circular #570-approved Surety Company is required, and the successful bidder must furnish Performance and Payment Bonds. The Bethlehem Housing Authority reserves the right to reject any or all bids. Further questions should be directed to Scott Speshok at 610-483-0322.

View the file

Other files

File Type Posted
02900 Landscaping.pdf PDF
16200 Electrical.pdf PDF
2-Parkridge PH 2 wage rates.pdf PDF
09670 Vinyl Composition Tile.pdf PDF
01010 General Work Requirements.pdf PDF
7-Parkridge PH 2 Addendum.pdf PDF
9-Bid table for Parkridge Phase 2.pdf PDF
06100 Rough Carpentry.pdf PDF
02210 Selective Demolition.pdf PDF
5-Parkridge PH2 IFB.pdf PDF
1-Parkridge documents to be submitted.pdf PDF
06650 Solid Polymer Fabrication.pdf PDF
15400 Plumbing.pdf PDF
06240 Plastic Laminate.pdf PDF
08110 Storm Doors.pdf PDF
08200 Flush Wood Doors and Frames.pdf PDF
07920 Sealants and Caulking.pdf PDF
01700 Project Close-out.pdf PDF
10300 Vinyl Coated Shelves.pdf PDF
3-Parkridge Ren. PH 2 Admin. Specs.pdf PDF
01545 Contractor Use of Premesis.pdf PDF
01500 Construction Facilities.pdf PDF
08100 Metal Doors and Frames.pdf PDF
6-Parkridge PH 2 Ren. Drawings.pdf PDF
09260 Gypsum Wallboard.pdf PDF
09650 Resilient Sheet Flooring.pdf PDF
8-Parkridge PH 2 Addendum 2.pdf PDF
09900 Painting.pdf PDF
0 Table of Contents.pdf PDF
01710 Cleaning.pdf PDF
01620 Storage and Protection.pdf PDF
12390 Kitchen Cabinetry.pdf PDF
06200 Finish Carpentry.pdf PDF
16000 Basic Electrical Requirements.pdf PDF
08541 Vinyl Windows.pdf PDF
10260 Fiberglass Wall Panels.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 05500

METAL FABRICATION

SUMMARY:

Provide miscellaneous metal work shown on the drawings, as specified herein, and as needed for complete and proper installation.

Documents affecting work of this section include, but are not limited to, General Conditions, Supplementary Conditions, Drawings, and these Technical Specifications.

SUBMITTALS:

Comply with the pertinent provisions of the General requirements.

Submit product data within 15 days of award of contract to the contractor.

Submit product data and material list of items to be provided under this Section. Supply sufficient technical data to demonstrate compliance with the specified requirements.

Submit shop drawings in sufficient detail to show fabrication, installation, anchorage, and interface of work of this Section with the work of other trades.

Manufacturers recommended installation procedures which, when approved by the Owner, will become the basis for accepting or rejecting actual installation procedures used on the work.

Submittals required for work under this Section include, but may not be limited to:

1.) Stainless steel backsplash behind all kitchen ranges. Provide one full size sample to the Owner for approval. Back splash shall be 20 GA.

stainless steel with number 4 brush finish. Finish all edges with matching trim caps and J-channel where required. Extend backsplash a minimum of 2 inches past the bottom edge of range hood and a minimum of 4 inches below the top of the range.

05500-1

QUALITY ASSURANCE:

Use an adequate number of skilled workmen who are thoroughly trained and experienced in the necessary crafts and who are completely familiar with the specified requirements and methods needed for proper performance of the work of this Section.

Provide shop and/or field welding required in connection with the work of this Section in strict accordance with pertinent recommendations of the “American Welding Society”.

DELIVERY, STORAGE, AND HANDLING:

Comply with the pertinent provisions of the General Requirements.

MATERIALS:

In fabricating items which will be exposed to view, limit material to those which are free from surface blemishes, pitting, rolled trade names, roughness and any other imperfections visible to the naked eye.

Comply with the following standards as pertinent:

1.) Steel plates, shapes, and bars, as pertinent.

2.) Steel plates to bent or cold-formed: ASTM A283, Grade-C.

3.) Steel tubing (hot formed, welded or seamless): ASTM A501.

4.) Steel bars and bar-size shapes: ASTN A306, Grade 60.

5.) Cold-finished steel bars: ASTM A108.

6.) Cold-rolled carbon sheets: ASTM A336.

Stainless steel sheets: AISI Type 302 or 304, gauge and finish as specified on drawings or herein.

7.) Galvanized carbon steel sheets: ASTM A526, with G90 zinc coating In accordance with ASTM A525.

05500-2

8.) Gray iron castings: ASTM A48, Class 10.

9.) Malleable iron castings: ASTM A47.

10.) Steel pipe: ASTM A53, Grade A, Schedule 40, black finish unless otherwise noted.

11.) Concrete inserts:

a.) Threaded or sledge type, galvanized ferrous castings of malleable iron complying with ASTM A27.

b.) Provide required bolts, shims, and washers, hot-dipped

Galvanized in accordance with ASTM A153.

FASTENERS:

For exterior use and where built into exterior walls, provide zinc-coated fasteners.

Provide fasteners of type, grade, and class required for the particular use.

Comply with the following standards as pertinent:

1.) Bolts and nuts: Provide hexagon-head regular type complying with ASTM A307, Grade A.

2.) Lag bolts: Provide square-head type complying with Fed Spec. FF-B-561.

3.) Machine Screws: Provide cadmium plated steel type complying with Fed Spec. FF-S-11

4.) Washers:

a.) Plain washers: Comply with Fed Spec. FF-W-92, round, carbon steel.

b.) Lock washers: Comply with Fed Spec. FF-W-84, helical spring type carbon steel.

05500-3

5.) Toggle bolts: Provide type, class, and style needed and comply with Fed Spec. FF-B-588.

6.) Anchorage devices: Provide expansion shield complying with Fed Spec. FF-S-325.

OTHER MATERIALS:

Provide other materials, not specifically described but required for complete and proper installation, as selected by the contractor and subject to approval of the Owner.

SHOP PAINT:

Primer: Use “10-99 Tnemec Primer” or “Rustoleum Number 5769 Primer”.

For repair of galvanizing, use a high zinc-dust content paint complying with MIL-P- 21035.

FABRICATION:

Except as otherwise shown on the contract drawings, approved shop drawings, or noted in technical specifications; use material of size, thickness, and type required to produce reasonable strength and durability in the work of this Section.

Fabricate with accurate angles and surfaces which are true to the required lines and levels, grinding exposed welds smooth and flush, forming exposed connections with hair-line joints, and using concealed fasteners wherever possible.

Prior to shop painting or priming, properly clean metal surface as required for the applied finish and for the proposed use of the item.

On surfaces inaccessible after assembly of erection, apply two coats of the specified primer. Change color of second coat to distinguish from the first coat.

EXECUTION:

Examine the areas and conditions under which work of this Section will be performed.

Correct conditions detrimental to timely and proper condition of the work. Do not proceed until unsatisfactory conditions are corrected.

05500-4

COORDINATION:

Coordinate as required with other trades to ensure proper and adequate provision of work of those trades for interface with work of this Section.

INSTALLATION:

Set work accurately into position, plumb, level, true, and free from rack.

Anchor material or equipment firmly into place.

Where field welding is required, comply with AWS recommended procedures of manual shielded metal-arc welding for appearance and quality of weld and for methods to be used in correcting welding work.

Grind exposed welds smooth and touch-up shop prime coats.

Do not cut, weld, or abrade surfaces which have been hot-dipped galvanized after fabrication and which are intended bolting or screwed connections.

Immediately after erection, clean the field welds, bolted connections and abraded areas of shop priming. Paint the exposed areas with the same material used for shop priming.

END OF SECTION