This is a Technical Specifications document for Section 06100 Rough Carpentry prepared by the Bethlehem Housing Authority for the renovation of 20 apartments at the Parkridge family development in Pennsylvania (Phase 2). The specification outlines comprehensive requirements for providing labor, materials, and installation of rough carpentry work including framing lumber, plywood sheathing, underlayment, fasteners, hardware, and blocking. Key materials include S4S grade-stamped framing lumber complying with PS20 standards, APA-rated sheathing and plywood products, pressure-treated lumber for exposed applications, hot-dipped galvanized fasteners for exterior and high-humidity areas, and heavy-duty asphalt-saturated felt paper. The contractor must submit product data and material submittals within 15 days of receiving the executed contract. All work must comply with applicable codes and regulations, including standards from the Western Wood Products Association, American Plywood Association, and NFPA guidelines. Sealed bids are due electronically on the PennBid site by Thursday, October 22, 2026 at 11:00 AM.

The specification requires quality control through skilled and experienced workmen, proper material storage and handling practices, and compliance with established grade stamps and industry standards. Specific installation requirements include staggered joint patterns for subflooring and underlayment, maximum 16-inch on-center spacing for studs and joists, full-length un-spliced members, fire-blocking in stud walls, cross-bridging between joists at maximum 4-foot intervals, and alignment of finished surfaces within 1/8 inch variation. Fastening requirements specify proper penetration depths, pilot holes to prevent splitting, and appropriate washers for bolted connections. A satisfactory Bid Bond in the amount of 10% of the bid must accompany each submission, and the successful bidder shall furnish Performance and Payment Bonds. Interested contractors should direct questions to Scott Speshok at 610-483-0322 and access contract documents on the PennBid website.

View the file

Other files

File Type Posted
02900 Landscaping.pdf PDF
16200 Electrical.pdf PDF
2-Parkridge PH 2 wage rates.pdf PDF
09670 Vinyl Composition Tile.pdf PDF
01010 General Work Requirements.pdf PDF
7-Parkridge PH 2 Addendum.pdf PDF
9-Bid table for Parkridge Phase 2.pdf PDF
02210 Selective Demolition.pdf PDF
5-Parkridge PH2 IFB.pdf PDF
1-Parkridge documents to be submitted.pdf PDF
06650 Solid Polymer Fabrication.pdf PDF
15400 Plumbing.pdf PDF
05500 Metal Fabrications.pdf PDF
06240 Plastic Laminate.pdf PDF
08110 Storm Doors.pdf PDF
08200 Flush Wood Doors and Frames.pdf PDF
07920 Sealants and Caulking.pdf PDF
01700 Project Close-out.pdf PDF
10300 Vinyl Coated Shelves.pdf PDF
3-Parkridge Ren. PH 2 Admin. Specs.pdf PDF
01545 Contractor Use of Premesis.pdf PDF
01500 Construction Facilities.pdf PDF
08100 Metal Doors and Frames.pdf PDF
6-Parkridge PH 2 Ren. Drawings.pdf PDF
09260 Gypsum Wallboard.pdf PDF
09650 Resilient Sheet Flooring.pdf PDF
8-Parkridge PH 2 Addendum 2.pdf PDF
09900 Painting.pdf PDF
0 Table of Contents.pdf PDF
01710 Cleaning.pdf PDF
01620 Storage and Protection.pdf PDF
12390 Kitchen Cabinetry.pdf PDF
06200 Finish Carpentry.pdf PDF
16000 Basic Electrical Requirements.pdf PDF
08541 Vinyl Windows.pdf PDF
10260 Fiberglass Wall Panels.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 06100

ROUGH CARPENTRY

SUMMARY:

Provide labor, wood, nails, bolts, screws, framing anchors, all other rough hardware, and all other accessories required, and perform rough carpentry for the construction shown on the drawings, as specified herein, and as needed for complete and proper installation.

Documents affecting work of this section include, but are not limited to, General Conditions, Supplementary Conditions, Drawings, and these Technical Specifications.

Provide wood treatment data, including the treatment plant certification of compliance with the indicated requirements.

QUALITY CONTROL:

Comply with all applicable laws, codes and regulations.

Use an adequate number of skilled workmen who are thoroughly trained and experienced in the necessary crafts and who are completely familiar with the specified requirements and the methods needed for proper performance of the work of this section.

In addition to complying with the pertinent codes and regulations of governmental bodies having jurisdiction, unless otherwise specifically directed or permitted by the Owner, comply with:

1) “Product Use Manual” of the Western Wood Products Association for selection and use of products.

2) “Plywood Specifications and Grade Guide” of the American Plywood Association.

3) “Standard Specifications for Grades of California Redwood Lumber” of the Redwood

Inspection Bureau for Redwood, when used.

06100-1

SUBMITTALS:

Provide submittals and product data for underlayment, standard sheathing, framing lumber, roofing felt, treated lumber, and all fasteners and anchors within 15 days of the contractor receiving the executed contract from the BHA.

QUALITY CONTROL:

Comply with all applicable laws, codes and regulations.

Use an adequate number of skilled workmen who are thoroughly trained and experienced in the necessary crafts and who are completely familiar with the specified requirements and the methods needed for proper performance of the work of this section.

DELIVERY, STORAGE AND HANDLING:

Comply with the pertinent provisions of the General Requirements.

Deliver the material to the job site or storage area and store, in a safe and secure area, out of the way of traffic, and shored up of the ground.

Identify framing lumber as to grades, and store each separately from other grades.

Use extreme care when off loading lumber to prevent damage, splitting and, breaking of materials.

GRADE STAMPS:

Identify framing lumber by the grade stamp of the West Coast Lumber Inspection Bureau, or such other grade stamp as approved in advance by the Owner. Identify plywood as to species, grade, number of plies, and glue type by the stamp of the American Plywood Association.

Identify other materials of this Section by the appropriate stamp of the agency approved in advance by the Owner.

06100-2

MATERIALS:

Provide manufactured lumber, S4S and grade stamped, to comply with PS20 and applicable grading rules if inspection agencies certified by ALSC’s board of review.

Provide lumber with a maximum of 15 percent moisture content at the time of dressing and shipment, for sizes 2” or less in thickness.

Provide lumber of the following product classification in grades and species indicated.

Light Framing: 2” to 4” thick, & 2” to 10” wide.

Studs: Hem-Fir 2” to 4” thick & 4” to 6” wide, and graded under WWPA, WCLIB, SPIB, OR NLGA rules.

Unless otherwise indicated, provide standard grade lumber for nailers, blocking, furring, and similar members.

For types of concealed application listed below, provide wood panel products complying with PS1 where applicable, and with “APA Performance Standard Policies for Structural Use Panels” (Form E445) for requirements indicated.

For the following types of application where exposure durability classification or span rating is not given, provide Exposure1 and rating required to suit the existing or indicated support spacing.

Subflooring: APA Rated Sheathing

Wall Sheathing: APA Rated Sheathing

Plywood Underlayment for VCT & Sheet Vinyl: APA Luan Underlayment., in thickness as indicated on the drawings.

Secure new luan with hardware spaced a maximum of three (3) inches at the outer perimeter of the plywood sheet, and a maximum of 6” spacing in both directions of the rest of the plywood field.

All underlayment and VCT shall be installed prior to installing wood or vinyl base material.

06100-3

Plywood Subfloor Material: APA, CDX Ext., exterior glue type, in thickness as indicated on the drawings. Install subfloor and underlayment using a staggered joint pattern in both directions.

Fasteners and anchors shall be of the size, type, strength, material and finish best suited for the application shown, or as otherwise noted on the drawings. Hot-dipped galvanized fasteners and anchors complying with ASTM A 153 shall be used for work exposed to the weather, in ground contact, and high relative humidity areas.

When using lag bolts comply with Fed. Spec FF-B-561 and for machine bolts comply with

ASTM A 307.

Use common nails except as otherwise shown on the drawings and comply with Fed.

Spec FF-N-1. Use galvanized nails for exterior locations.

Joist hangers shall be Simpson, Teco, or Owner approved equal.

Pressure treated lumber and plywood shall be coated with water-borne preservatives to comply with AWPA C2 and C9 respectively.

Use exterior type treated lumber for exposed applications including nailers, blocking and similar items.

Felt paper shall be heavy duty, asphalt saturated felt, non-perforated, complying with

ASTM D 226.

Use Heavy Duty Resin Type felt paper beneath all metal roofs or type of paper otherwise recommended by metal roof manufacturer and approved by the Owner.

OTHER MATERIALS:

Provide other material, not specifically described but required for a complete and proper installation, as selected by the contractor subject to approval by the Owner.

06100-4

Deliveries:

Stockpile materials sufficiently in advance of need to assure availability for performing work in a timely manner.

Execution:

Install rough carpentry to comply with “Manual of House Framing” by National Forest Products Association (NFPA) and with the recommendations of the American Plywood Association (APA), unless otherwise indicated. For sheathing, underlayment and other products not covered in above standards, comply with the recommendations of the manufacturer of each individual product involved.

Produce joints that are tight, true, and well nailed, with members assembled in accordance with the drawings and pertinent codes and regulations.

Carefully select the members. Select individual pieces so that knots and obvious defects will not interfere with the placing bolts or proper nailing of members which will not allow making of proper connections.

Cut out and discard defects which render any piece of lumber unable to serve its intended purpose.

Lumber may be rejected by the Owner, whether or not it has been installed, for excessive warp, twist, bow, crook, mildew, fungus, or mold, as well as for improper cutting and/or fitting.

Flooring shall be secured from the center working to the perimeter or from one end to the other. Perimeter shall not be secured first.

Set carpentry work to the required level and lines, with members true, level and plumb, square, and for proper fit. Do not shim any framing component.

Securely attach carpentry work to substrates and supporting members using fasteners of size that properly support work but will not penetrate members where opposite side of wall will be exposed to view or receive finish material.

Install fasteners without splitting wood – drill pilot holes if necessary. Fasten products to allow for expansion at joints where necessary.

Provide wood framing members of size and spacing indicated.

06100-5

Do not splice members together to form full length members or studs. Use full length framing members and studs, un-spliced and platform framed, unless otherwise shown on the drawings.

Use common nails except as otherwise shown on the drawings and comply with Fed.

Spec FF-N-1. Use galvanized nails for exterior locations.

Provide nails where penetration into the piece of wood receiving the point of not less than ½ the length of the nail or spike used, however, that 16d nails may be used to connect two pieces of 2” (nominal) thickness.

When bolting lumber in place, pre-bore holes 1/16” in diameter larger than diameter of bolts being used. Drill straight and true from one side only. Do not bear bolt heads on wood. Use washers under head and nut where both bear on wood, and use washers under all nuts.

When using lag bolts comply with Fed. Spec FF-B-561 and for machine bolts comply with ASTM A 307. For lag bolts, pre-bore holes same diameter as roof of threads, enlarging holes to shank diameter for length of shank.

In addition to framing operations normal to fabrication and erection indicated on the drawings, install wood blocking and backing required for the work of the other trades.

Blocking shall be 2x6’s of appropriate length necessary to span stud to stud or floor joist to floor joist. Blocking or bridging shall be installed by either the general contractor or subcontractors for any existing material or fixtures they are replacing or for any new material or fixtures they are installing on all walls and ceilings. Properly coordinate this portion of work with all other trades involved with this project.

Install blocking to cut off concealed draft openings, both horizontal and vertical, between ceiling and floor areas and as follows:

1) Fire block wall in all stud walls at ceiling and floor levels.

2) Fire block in all stud walls, including furred spaces, so that the maximum dimension of each concealed space is not greater than 8 feet (8’).

3) All other locations where openings could afford passage for rodents, flames or smoke shall be fire-blocked.

06100-6

Install wood cross-bridging (not less than 2 x 3 nominal), or metal cross-bridging of equal strength, between new joists.

Provide bridging at a maximum distance 4’- 0” between a line of bridging and bearing.

Install solid wood blocking between the mid-point of spans exceeding 8’- 0” or as otherwise shown on the drawings.

Install solid wood blocking between joists at points of support and wherever sheathing is discontinuous. Blocking may be omitted where joists are supported with metal hangers, upon approval of the Owner.

On framing members to receive a finished surface, align finished surfaces to vary not more than 1/8” from the plane of surfaces of adjacent furring and framing members.

Framing shall be packed out, where required, so new finish surfaces align with existing finish surfaces.

Set horizontal and sloped member with crown up.

Unless otherwise shown on the drawings, frame all corners and intersections with three or more studs and all required bearing for wall finish.

Unless otherwise shown on the drawings, all studs and joist shall be placed at a maximum if 16” on centers.

Do not notch, cut, or bore members for pipe, duct work, or conduits, of for any other reason except as shown on the drawings and/or as specifically approved in advance by the Owner.

Make bearings full unless otherwise indicated on the drawings.

Finish bearing surfaces on which structural members are to rest so as to give sure and even support.

When framing members slope, cut and/or notch the ends as required to give uniform bearing surface.

Properly brace and support all ceilings, floors, joists, and all other bearing surfaces until new walls and support headers are in place.

Install double 2 x12 wood headers where required for proper support & construction

END OF SECTION