This is a specification document for sealants and caulking work (Section 07920) related to the Bethlehem Housing Authority's project to renovate 20 apartments at the Parkridge family development in Pennsylvania. The specification establishes requirements for sealing and caulking joints throughout the work to provide barriers against moisture and air passage. Contractors must submit product data within 15 days of contract award, including samples of each sealant, backing material, primer, and bond breaker proposed for use. The work must be performed by skilled, experienced workmen trained in the specified requirements and methods. Sealed bids are due electronically on the PennBid site by Thursday, October 22, 2026 at 11:00 AM, with contract documents available on the PennBid website. A 10% Bid Bond secured by a Surety Company appearing in Department of Treasury Circular #570 must accompany each bid submission, and the successful bidder will be required to furnish satisfactory Performance and Payment Bonds.
The specification requires sealants meeting ASTM C-920, Class 25 standards, with acceptable products including GE7000 (white) or GE M90033 (clear) or owner-approved equals, with colors selected by the owner from standard available options. Backup materials must be non-absorbent, non-staining, and manufacturer-recommended for the specific installation. Surface preparation requirements are detailed for concrete, masonry, steel, and aluminum surfaces, including sandblasting, wire brushing, and removal of dust, oil, grease, and protective coatings as applicable. Prior to full-scale mobilization, the contractor must provide an approved sample installation that establishes the quality and workmanship standard for the entire project. All debris, empty containers, and surplus material must be removed from the job site upon completion. Questions regarding the contract should be directed to Scott Speshok at 610-483-0322, and the Bethlehem Housing Authority reserves the right to reject any or all bids or waive any informalities.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 07920
SEALANTS AND CAULKING
SUMMARY:
Throughout the work, seal and caulk joints where shown on the drawings and elsewhere to provide a positive barrier against the passage of moisture and air.
Documents affecting the work of this section include, but are not necessarily limited to, General Conditions, Supplementary Conditions, Drawings, and these specifications.
SUBMITTALS:
Comply with pertinent provisions of the General Requirements.
Submit product data within 15 days of award of contract to the contractor.
Submit product data and material list of items to be produced under this section. Supply sufficient technical data to demonstrate compliance with the specified requirements.
Provide manufacturer’s recommended installation procedures which, when approved by the owner, will be incorporated into these specifications and contract documents.
Submit samples of each sealant, backing material, primer, and bond breaker proposed for use.
QUALITY ASSURANCE:
Use adequate number of skilled workmen who are thoroughly trained and experienced in the necessary crafts and who are completely familiar with the specified requirements and methods needed for the proper performance of work covered under this section.
DELIVERY, STORAGE AND HANDLING:
Comply with pertinent provisions of the General Requirements.
Do not retain at the job site material which has exceeded the shelf life recommended by its manufacturer.
07920-1
SEALANT:
Provide the following sealant, or owner approved equals, where called for on the drawings or otherwise required for a complete and proper installation.
Sealant Type:
Shall meet ASTM C-920, Class 25.
Acceptable products; GE Sealants and Adhesives:
GE7000 – white M90033 – clear
Or owner approved equal. Colors to be chosen by owner.
For other applications, provide products especially formulated for the proposed use and approved in advance by the owner.
COLORS:
Colors for each sealant installation shall be selected by the owner from standard colors normally available from the specified manufacturer.
Should such standard color not be available from an approved substitute manufacturer except at additional charge, provide such color at no additional cost to the owner.
PRIMERS:
Use only those primers which have been tested for durability on the surface to be sealed and are specifically recommended for this installation by the manufacturer of the sealant used.
Use only the primer approved by the owner for the particular installation, applying in strict accordance with the manufacturer’s recommendations as approved by the owner.
BACKUP MATERIALS:
Use only those backup materials which are non-absorbent, non-staining, and specifically recommended for this installation by the manufacturer of the sealant being used.
07920-2
MASKING:
For masking around joints, provide an appropriate masking tape which will effectively prevent application of sealant on surfaces not scheduled to receive it, and which is removable without damage to the substrate.
OTHER MATERIALS:
Provide all additional material, equipment and labor not specifically described, in these specifications or on the drawings, but necessary to provide a complete and proper installation acceptable to the owner.
SURFACE CONDITIONS:
Examine the areas and conditions under which work of this section will be performed.
Correct all conditions detrimental to timely and proper completion of the work. Do not proceed until unsatisfactory conditions are corrected.
PREPARATION:
Concrete and masonry surfaces:
1. Unless shown otherwise on the drawings, new sealant shall be applied over existing sealant. Install only on surfaces which are dry, sound, and well brushed, wiped free from dust.
2. At open joints, remove dust by mechanically blown compressed air, if so required.
3. Remove oil and grease, use sandblasting or wire brushing.
4. Where surfaces have been treated, remove the surface treatment by sandblasting or wire brushing.
5. Remove laitance and mortar from joint cavities.
Steel surfaces in contact with sealant:
1. Sandblast as required to achieve acceptable surface for bond.
07920-3
2. If, in the opinion of the owner, sandblasting is not practicable, or would damage adjacent finish, scrape or wire brush the metal to remove all mill, scale and rust.
3. Remove protective coatings on steel by sandblasting or using a solvent which leaves no residue.
Aluminum surfaces in contact with sealant:
1. Remove all temporary protective coatings, dirt, oil and grease.
2. Use only such solvents to remove protective coatings as are recommended for that purpose by the manufacturer of the material being cleaned, and which are non-staining.
BOND BREAKER INSTALLATION:
Provide an approved bond-breaker where recommended by the manufacturer of the sealant, and approved by the owner, adhering strictly to the manufacturer’s installation recommendations.
INSTALLATION OF SEALANTS:
Prior to the start of installation in each joint, verify the joint type according to details on the drawings, or as otherwise directed by the owner, and verify that the required proportion of width of joint to depth of joint has been secured.
Apply sealant under pressure with power actuated hand gun, manually operated hand gun, or by other appropriate means. Application method shall be approved by the owner.
Use guns with nozzles of proper size, and providing sufficient pressure to completely fill the joints as designed.
Thoroughly and completely mask joints where the appearance of the primer or sealant on adjacent surfaces would not be acceptable to the owner.
Install sealant in strict accordance with the manufacturer’s recommendations, thoroughly filling joints to the recommended depth.
07920-4
Tool joints to the profile shown on the drawing, or as otherwise directed by the owner if such profile is not shown on the drawings. Tool all joints to provide uniformly smooth joints with a slightly concave surface.
Prior to full scale mobilization and installation, the contractor shall provide a sample of the sealant installation and method. Once the sample is approved by the Owner, it shall be used as the standard of quality and workmanship throughout the duration of the project.
Clean adjacent surfaces free from sealant as the installation progresses, using solvent or cleaning agent recommended by the manufacturer of the sealant being used, and approved by the owner.
Upon completion of the work of this Section, promptly remove from the job site all debris, empty containers, and surplus material derived from this portion of the work.
END OF SECTION