Attached to
Bomber Agile Common Hangar; 4-Dock Hangar at Tinker Air Force Base
Solicitation number
W912BV25S0014
Issued by

About this file

This file contains technical drawings and specifications for the Bomber Agile Common Hangar project at Tinker Air Force Base, focusing on grounding details, lightning protection coverage zones, electrical classifications, and communications/security system layouts. The drawings include detailed specifications for aircraft static ground receptacles, shop static bond bar details, and hangar lightning protection zones with 150' radius coverage areas.

The drawings show comprehensive communications infrastructure plans for both first and second floors, including locations of wireless access points, cable pathways, and equipment room layouts. Security systems drawings detail access control points, surveillance camera locations, and audio-visual system placements throughout the facility. Specific technical details include ground receptacle specifications requiring 25 ohms maximum resistance, cable tray routing specifications, and communications room layouts with equipment rack elevations. The drawings are marked as 65% design completion, dated November 20, 2024, and were prepared by Mason and Hanger under USACE Tulsa District contract numbers W912BV-20-D-0008 and W912BV-20-D-0032.

View the file

Other files

File Type Posted
WWYK263009_65 Design Analysis_Part12_Part2.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part6_Part1.pdf PDF
WWYK263009_65 Design Analysis_Part18_Part6.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part1.pdf PDF
WWYK263009_65 Design Analysis Part 28_Part3.pdf PDF
WWYK263009_65 Drawings_Volume 2_Part5.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part6_Part2.pdf PDF
WWYK263009_65_NG-LCCA_BLCC_Summary Report.pdf PDF
WWYK263009_65 Design Analysis_Part24.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part4_Part7.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part4.pdf PDF
WWYK263009_65 Design Analysis_Part22_Part4_Part3.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part4_Part1.pdf PDF
WWYK263009_65 Design Analysis_Part17.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part19_Part3.pdf PDF
WWYK263009_65 Design Analysis_Part10.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part8.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part1.pdf PDF
WWYK263009_65_NG_energy model results.pdf PDF
Bomber Agile Common Hangar Industry Forum Presentation.pdf PDF
WWYK263009_65 Design Analysis_Part22_Part4_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part18_Part2.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part4_Part4.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part7.pdf PDF
WWYK263009_65 Design Analysis_Part21.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part6_Part4_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part23.pdf PDF
WWYK263009_65 Design Analysis_Part22_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part4.pdf PDF
WWYK263009_65 Design Analysis_Part19_Part2.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part3.pdf PDF
WWYK263009_65 Design Analysis_Part20.pdf PDF
WWYK263009_65 Design Analysis Part 28_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part26.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part5.pdf PDF
WWYK263009_65 Design Analysis_Part19_Part4.pdf PDF
WWYK263009_65 Design Analysis_Part27.pdf PDF
WWYK263009_65 Design Analysis_Part18_Part5.pdf PDF
WWYK263009_65 Design Analysis_Part15.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part3.pdf PDF
WWYK263009_65 Design Analysis Part 28_Part4.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part9.pdf PDF
WWYK263009_65 Design Analysis_Part9.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part4.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part1.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part5.pdf PDF
WWYK263009_65_NG-LCCA_BLCC results.pdf PDF
WWYK263009_65 Design Analysis_Part7.pdf PDF
Show 40 more

Latest 50 of 95 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/4 " X 2" (6mm x 51mm) copper bar

4 ft (1220mm) o.c. max

SILVER SOLDER

OR EXOTHERMIC

WELD TO BAR

COPPER GROUNDING

LUG, PRESSURE

CRIMP TYPE

#1/0 COPPER GROUND

WIRE. ISOLATE FROM

BUILDING STEEL, CONDUIT

& WALL PANELS.

1/4" X 2" (6mm X 51mm)

COPPER BAR

STAINLESS STEEL

WASHER & LOCK

WASHER

STAINLESS STEEL

ANCHOR BOLT

STAINLESS STEEL

ANCHOR STUD

2" (51mm) STAND-OFF

INSULATOR, FIBERGLASS

REINFORCED POLYESTER

FACE OF WALL

BOLT & SILVER SOLDER ANY LAP JOINT

SPLICE OR EXOTHERMICALLY BUTT WELD

THE JOINTS

2-1/2" (64mm)

IN HANGERS, MAX

RESISTANCE TO

GROUND SHALL BE

25 OHMS FROM

ANY GROUND ROD

3/4" (19mm)

2 - 7/8" (73mm)

2 ft (610mm) MIN.

FOR HANGERS

8 ft (2438mm) MIN.

FOR HYDRANT

REFUELING SYSTEM

BRASS PIN

CAST BRONZE

HOUSING

#10 BRASS BALL CHAIN

FINISHED HANGAR FLOOR

OR APRON PAVEMENT

3/4" N.C. THREAD

EPOXY OR SPOT WELD THREAD

COUPLING AFTER COMPLETING

ALIGNMENT WITH HANGAR FLOOR.

INCLUDING COVER ALIGNMENT.

INSTALL PIGTAIL TO CONNECT TO

FACILITY GROUND GRID; DO NOT

CUT GROUND GRID WIRES.

INSTALL BELOW CONCRETE SLAB.

EXOTHERMIC BONDING.

ELEVATION

PLAN

2-3/4" (70mm) DIA.

CAST BRONZE COVER,

FRICTION FIT

GROUND

PAINT YELLOW

RED PAINT

18" (457mm) DIA. 2"

(51mm) 2" (51mm)

GROUND

RECEPTACLE

SET IN FLOOR

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

300 West Vine Street Suite 1500 Lexington, KY 40507

(859) 252-9980

Mason and Hanger

S N

A L L

W B

V -2

-D

-0

W B

V -2

-D

-0

EG502

G R

O U

N D

IN

G

D E

T A

IL

S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

T C

R A

D D

O C

K

K A

P P

IA

J W

E D

E L

N O

V E

M B

E R

D

E S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

SCALE: NTSEG502

SHOP STATIC BOND BAR DETAILD1

SCALE: NTSEG502

AIRCRAFT STATIC GROUND RECEPTACLE DETAILD7

D E

S

IG

N

/2

/2

HANGAR

SINGLE STORY

ADMIN &

STORAGE

PROTECTION

ZONE

150' RADIUS

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

300 West Vine Street Suite 1500 Lexington, KY 40507

(859) 252-9980

Mason and Hanger

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

S N

A L L

W B

V -2

-D

-0

W B

V -2

-D

-0

EG503

L

IG

H T

N

IN

G P

R O

T E

C T

IO

N

C O

V E

R A

G E

Z O

N E

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

T C

R A

D D

O C

K

K A

P P

IA

J W

E D

E L

N O

V E

M B

E R

D

E S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

SCALE: 1/8" = 1'-0"X1-001-3

LIGHTNING PROTECTION ZONEA1

SCALE: 1/8" = 1'-0"EG503

LIGHTNING PROTECTION ZONEE1

D E

S

IG

N

/2

150' RADIUS

HANGAR

SINGLE STORY

SHOPS & STORAGE

PROTECTED ZONE

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

300 West Vine Street Suite 1500 Lexington, KY 40507

(859) 252-9980

Mason and Hanger

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

S N

A L L

W B

V -2

-D

-0

W B

V -2

-D

-0

EG504

L

IG

H T

N

IN

G P

R O

T E

C T

IO

N

Z O

N E

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

T C

R A

D D

O C

K

K A

P P

IA

J W

E D

E L

N O

V E

M B

E R

D

E S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

SCALE: 1/8" = 1'-0"X1-001-2

LIGHTNING PROTECTION ZONED1

D E

S

IG

N

/2

CLASSIFICATION LEGEND

CLASS I DIV 1 BELOW

FINISHED FLOOR ELEVATION.

NON-CLASSIFIED

WITHIN SPACES HATCHED,

CLASS I DIVISION 2, FROM

FINISHED FLOOR TO 18"AFF.

CORRIDOR

104C

TC OFFICE

TOOL CHECKOUT

TOOL CRIB

104A

COMPOSITE

FOM STORAGE

104E

AMT

104D

TC OPEN OFF.

104B

KITTING

LANDING GEAR SHOP

VEST.

VEST.

VEST.

HAZ STOR

DLA/IPV

COMPOSITE

MENS

MENS

VEST. 019

CORRIDOR

VEST.

WOMENS

BRK RM/TORNADO

SHELTER

021D

CLOSET (NDI)

JAN

021C M

021B W

021A

WELL

ELEC

MECH

MECH

ELEC

PSC

DOCK OFFICE

SC1

STAIR

100A

CORRIDOR

MENS

JAN

WOMENS

125A

CLOSET

WELL

MACH RM

LO STOR

VEST. 118A

CORRIDOR

DOCK OFFICE

COMM

CORRIDOR

DOCK OFFICE

MENS

WOMENS

JAN

SHEET METAL

TIRE (OPEN) SHOP

ENGINE SHOP

CORRIDOR

VEST.

HANGAR DOCK #1

HANGAR DOCK #3

HANGAR DOCK #4

HANGAR DOCK #2

102A

HAZ WSTE

TRENCH DRAIN

TRENCH DRAIN

015A

AIR

PMD

127D

SERVER

EXIT PASSAGEWAY

DOCK OFFICE

E1

ELEV

SB1

STAIR

BRK RM/TORNADO

SHELTER

COMM

FIRE

AIR

2 3

101A

FOM OFF.

VEST.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

300 West Vine Street Suite 1500 Lexington, KY 40507

(859) 252-9980

Mason and Hanger

8'-0" 16'-0" 32'-0"

1/16" = 1'-0"

KEYPLAN

S N

A L L

W B

V -2

-D

-0

W B

V -2

-D

-0

E-110

F

IR

S T

F L O

O R

E

L E

C T

R

IC

A L C

L A

S S

IF

IC

A T

IO

N

P L A

N

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

T C

R A

D D

O C

K

K A

P P

IA

J W

E D

E L

N O

V E

M B

E R

D

E S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

SCALE: 1/16" = 1'-0"E-110

FIRST FLOOR - ELECTRICAL CLASSIFICATION PLANA1

GENERAL SHEET NOTES

1 FOR LEGENDS SEE SHEET E-001.

2 FOR GENERAL NOTES SEE SHEET E-002.

3 FOR ABBREVIATIONS SEE SHEET E-003.

SHEET KEYNOTES

1 THE AREA WITHIN 5’-0” HORIZONTALLY

FROM ANY AIRCRAFT SURFACE AND

VERTICALLY FROM 5’-0” ABOVE THE

UPPER AIRCRAFT SURFACE DOWN TO

THE FLOOR IS CLASSIFIED AS CLASS I,

DIVISION 2.

2 ALL WIRING INSTALLED IN OR UNDER THE

HANGAR FLOOR SHALL COMPLY WITH

THE REQUIREMENTS FOR CLASS I,

DIVISION 1 LOCATIONS. WHERE SUCH

WIRING IS LOCATED IN VAULTS, PITS, OR

DUCTS, ADEQUATE DRAINAGE SHALL BE

PROVIDED.

3 UNINTERRUPTED RACEWAYS THAT ARE

EMBEDDED IN A HANGAR FLOOR OR

BURIED BENEATH THE HANGAR FLOOR

SHALL BE CONSIDERED TO BE WITHIN

THE CLASS I LOCATION ABOVE THE

FLOOR, REGARDLESS OF THE POINT AT

WHICH THE RACEWAY DESCENDS BELOW

OR RISES ABOVE THE FLOOR.

4 ALL ELECTRICAL WORK AT THE

STRUCTURAL BOUNDARIES OF THIS

ENTIRE SPACE SHALL BE SURFACE

MOUNTED. EACH CONDUCTIVE RACEWAY

PENETRATING THE STURCTURAL

BOUNDARIES OF THIS ENTIRE SPACE

SHALL BE EITHER, PROVIDED WITH A

NON-CONDUCTIVE SEGMENT, OR SHALL

BE BONDED TO GROUND IMMEDIATELY

INSIDE THE SPACE’S STRUCTURAL

BOUNDARY. THESE REQUIREMENTS ARE

INDEPENDENT OF, AND SHALL BE

COORDINATED WITH, THE NFPA

CLASSIFICATIONS NOTED ON THIS SHEET.

5 ALL ELECTRICAL WORK AT THE

STRUCTURAL BOUNDARIES OF THIS

ENTIRE GROUP OF SPACES SHALL BE

SURFACE MOUNTED. EACH CONDUCTIVE

RACEWAY PENETRATING THE

STURCTURAL BOUNDARIES OF THIS

ENTIRE GROUP OF SPACES SHALL BE

EITHER, PROVIDED WITH A

NON-CONDUCTIVE SEGMENT, OR SHALL

BE BONDED TO GROUND IMMEDIATELY

INSIDE THE GROUP OF SPACES’

STRUCTURAL BOUNDARY. THESE

REQUIREMENTS ARE INDEPENDENT OF,

AND SHALL BE COORDINATED WITH, THE

NFPA CLASSIFICATIONS NOTED ON THIS

SHEET.

D E

S

IG

N

/2

218F

OFFICE

218G

OFFICE

218E

OFFICE

218D

OFFICE

218C

OFFICE

218B

OFFICE

218A

OFFICE

WOMENS

MENS

MECH

202A

ELEC

202B

OFFICE

202C

OFFICE

202D

OFFICE

202E

OFFICE

SFTWR

202K

COLLAB

CTR TRNG

209B

OFFICE

209A

OFFICE

ELEC

SCHED OFF

BRK

CORRIDOR

M

W

STOR

E2

ELEV

218K

ELEC

AMXS

SB2

STAIR

CLASSIFICATION LEGEND

NON-CLASSIFIED

COMM

OPEN OFFICE

202F

OFFICE202G

COPY/FILE

202H

OFFICE

202I

OFFICE

202J

OFFICE

218I

CONF

218J

CONF

218H

COPY

214C

COMMAND SUITE

214B

DEPUTY

RECEPTION

214A

DEPUTY

JAN

RECYCLING

SC2

STAIR

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

300 West Vine Street Suite 1500 Lexington, KY 40507

(859) 252-9980

Mason and Hanger

8'-0" 16'-0" 32'-0"

1/16" = 1'-0"

KEYPLAN

S N

A L L

W B

V -2

-D

-0

W B

V -2

-D

-0

E-120

S E

C O

N D

F L O

O R

E

L E

C T

R

IC

A L C

L A

S S

IF

IC

A T

IO

N

P L A

N

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

T C

R A

D D

O C

K

K A

P P

IA

J W

E D

E L

N O

V E

M B

E R

D

E S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

SCALE: 1/16" = 1'-0"E-120

SECOND FLOOR - ELECTRICAL CLASSIFICATION PLANA1

GENERAL SHEET NOTES

1 FOR LEGENDS SEE SHEET E-001.

2 FOR GENERAL NOTES SEE SHEET E-002.

3 FOR ABBREVIATIONS SEE SHEET E-003.

D E

S

IG

N

/2

COMMUNICATIONS SYMBOLS

BUILDING ENTRANCE TERMINAL

PUNCH BLOCK - 110 STYLE

TELECOMMUNICATIONS MAIN GROUNDING BUS BAR

SURFACE RACEWAY - REFER TO KEYED NOTES AND

SPECIFICATIONS FOR TYPES

2-POST EQUIPMENT RACK WITH VERTICAL CABLE

MANAGERS - 'F' INDICATES FRONT OF RACK

4-POST EQUIPMENT RACK WITH VERTICAL CABLE

MANAGERS - 'F' INDICATES FRONT OF RACK

TELECOMMUNICATIONS GROUNDING BUS BAR

BET

PB

TGB

TMGB

F

F

EQUIPMENT CABINET - 'F' INDICATES FRONT OF CABINETF

MB MEDIA BOX

F

P

FLOOR BOX (BY DIVISION 26)

POWER POLE (BY DIVISION 26)

ACCESS CONTROLLED DOOR. REFER TO ACCESS CONTROLLED

DOOR SCHEDULE FOR ADDITIONAL INFORMATION.

SECURITY SYSTEM SYMBOLS

ACD

CREDENTIAL READERCR

ACCESS CONTROL SYMBOLS:

INTRUSION DETECTION SYMBOLS:

MD MOTION DETECTOR

VS VIBRATION SENSOR

WORKSTATION SYMBOLS:

S PC SPEAKER

DISPLAY - DESKTOP-MOUNTED

DESKTOP PC

KEYBOARD AND MOUSE

GENERAL NOTES

1. PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT REQUIRED TO INSTALL

COMPLETE TECHNOLOGY SYSTEMS AS INDICATED ON THESE DRAWINGS AND

AS SPECIFIED.

2. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE DETAILS OF WORK,

VERIFY DIMENSIONS IN THE FIELD, AND ADVISE THE ARCHITECT/ENGINEER OF

ANY DISCREPANCY BEFORE PERFORMING ANY WORK.

3. COORDINATE LOCATION AND MOUNTING REQUIREMENTS OF ALL CEILING-

MOUNTED OR ABOVE-CEILING-MOUNTED DEVICES WITH REFLECTED CEILING

PLAN, LIGHTING LAYOUT, SIGNAGE, AND OTHER CEILING OR ABOVE-CEILING-

MOUNTED EQUIPMENT.

4. MOUNT ALL TECHNOLOGY OUTLETS AT HEIGHTS ABOVE FINISHED FLOOR AS

SHOWN IN THE TECHNOLOGY OUTLET SCHEDULE U.N.O.

5. ALL TECHNOLOGY RACEWAY (CONDUIT, BACKBOX, SUPPORTS) SHALL BE

PROVIDED BY DIVISION 26. SEE DIVISION 26 SPECIFICATIONS FOR GENERAL

RACEWAY REQUIREMENTS. ADDITIONAL REQUIREMENTS INCLUDE:

• PROVIDE A BEND RADIUS OF TEN TIMES THE OUTSIDE DIAMETER OR

GREATER FOR ALL TECHNOLOGY RACEWAY.

• PROVIDE A MINIMUM CONDUIT SIZE OF 1" UNLESS NOTED OTHERWISE.

• PROVIDE PLASTIC OR NYLON BUSHINGS ON ALL CONDUIT STUBS PRIOR

TO THE INSTALLATION OF CABLES.

6. MOUNT TECHNOLOGY SYSTEMS EQUIPMENT/DEVICES SO AS TO ALLOW

ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF

TECHNOLOGY SYSTEMS EQUIPMENT/DEVICES ON EQUIPMENT SUPPLIED BY

ANOTHER CONTRACTOR SHALL BE COORDINATED WITH AND APPROVED BY

THAT CONTRACTOR IN ADVANCE OF INSTALLATION.

7. PROVIDE ALL OPENINGS REQUIRED IN WALLS. REPAIR ALL OPENINGS TO

MATCH EXISTING USING A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS

CONTRACTOR. GROUT OR SEAL ALL CONDUITS THROUGH WALLS INTO

OPENINGS. FIRESTOP ALL PENETRATIONS THROUGH FLOORS AND FIRE-

RATED WALLS IN A MANNER THAT MAINTAINS THE RATING OF THE FLOOR OR

WALL PENETRATED.

8. PROVIDE ALL TRENCHING AND BACKFILL FOR BURIED TECHNOLOGY

SYSTEMS CONDUITS UNLESS NOTED OTHERWISE.

9. PROVIDE METALLIC TAPE ABOVE BURIED PVC CONDUIT FOR FUTURE

LOCATING.

10. CONDUIT ROUTED UNDER THE BUILDING SHALL BE MINIMUM 18" BELOW SLAB.

SITE SYMBOLS

HANDHOLEHH

MANHOLEMH

SECURITY POLE FOR CAMERA. REFER TO VIDEO

SURVEILLANCE SYMBOLS FOR CAMERA TYPES.

LINE TYPE KEY

EXISTING TO BE REMOVED BY THIS

CONTRACTOR (DARK DASHED LINE)

EXISTING TO REMAIN WORK

(THIN SOLID LINE)

NEW WORK BY THIS CONTRACTOR

(DARK SOLID LINE)

NEW WORK UNDER FLOOR BY

THIS CONTRACTOR

SITE UNDERGROUND CONDUITCON

SITE REMOVED UNDERGROUND

CONDUIT

//CON//

SITE UNDERGROUND FIBER OPTICFOC

SITE REMOVED UNDERGROUND FIBER

OPTIC

//FOC//

AUDIO VISUAL SYMBOLS

LOUDSPEAKER - HORN TYPE

LOUDSPEAKER - PENDANT-MOUNTED

DISPLAY - WALL-MOUNTED. REFER TO DRAWINGS FOR TYPE.

DISPLAY - CEILING-MOUNTED. REFER TO DRAWINGS FOR

TYPE.

DISPLAY(S) - CEILING-MOUNTED, BACK-TO-BACK. REFER TO

DRAWINGS FOR TYPE.

S

S

S

S

LOUDSPEAKER - CEILING-MOUNTED

LOUDSPEAKER - WALL-MOUNTED

PS PAGING STATION

VIDEO SURVEILLANCE SYMBOLS

F

C

F

F

MOUNTING MODIFIERS:

WALL MOUNT

F APPROXIMATE VIEWING DIRECTION

CAMERA TYPE:

C: DETENTION CORNER

F: FIXED W/ VARIFOCAL LENS

M: MULTISENSOR

O: FISHEYE

P: PAN-TILT-ZOOM

XX

HORIZONTAL VIEWING ANGLE

CAMERA ID

POLE MOUNT

EXTERIOR CORNER MOUNT

INTERIOR CORNER MOUNT

VIDEO SURVEILLANCE CAMERA:

CEILING MOUNTF

GENERAL SYMBOLS

9.XXX

T-40X

T-40X

DETAIL NUMBER / SHEET NUMBERX/T-XXX

A

T-40X 1

KEYED NOTE, USED TO DESCRIBE ADDITIONAL

INFORMATION OF WORK REQUIRED, SPECIFIC TO

THE SHEET AND/OR DETAIL IT IS SHOWN WITH

IT ROOM

116 ROOM NAME AND NUMBER

DOOR IDENTIFICATION

BUILDING SECTION

ENLARGED PLAN

INTERIOR ELEVATION

TECHNOLOGY OUTLET SCHEDULE NOTES:

1. REFER TO DIVISION 26 SPECIFICATIONS FOR BOX AND CONDUIT SPECIFICATIONS AND EXECUTION REQUIREMENTS.

2. REFER TO DIVISION 27 SPECIFICATIONS FOR LOW-VOLTAGE CABLING PATHWAY REQUIREMENTS.

WIRELESS ACCESS POINT TECHNOLOGY OUTLET:

- (1) 1" CONDUIT STUB

- (1) 4-11/16" SQUARE x 2-5/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING

- (1) SINGLE-GANG, TWO-PORT FACEPLATE

- (2) CATEGORY 6 JACKS

- (2) CATEGORY 6 CABLES

- BOX OR TWO-PORT

SURFACE HOUSING AS

NECESSARY TO MEET

INSTALLATION

CONDITIONS

- INCLUDE 30' COILED

SLACK CABLE FOR AP

LOCATION ADJUSTMENT

SEE COMMENTS

TECHNOLOGY OUTLET SCHEDULE

SYMBOL MOUNTINGDESCRIPTION COMMENTS

SINGLE-PORT TECHNOLOGY OUTLET:

- (1) 1" CONDUIT

- (1) 4-11/16" SQUARE x 2-5/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING

- (1) SINGLE-GANG, SINGLE-PORT FACEPLATE

- (1) CATEGORY 6 JACK

- (1) CATEGORY 6 CABLE

18" AFF TO CENTER

OF BOX U.N.O.

TWO-PORT TECHNOLOGY OUTLET:

- (1) 1" CONDUIT

- (1) 4-11/16" SQUARE x 2-5/8" DEEP BACKBOX WITH SINGLE GANG TRIM RING

- (1) SINGLE-GANG, TWO-PORT FACEPLATE

- (2) CATEGORY 6 JACKS

- (2) CATEGORY 6 CABLES

18" AFF TO CENTER

OF BOX U.N.O.

AP

CAMERA BACKBOX SCHEDULE NOTES:

1. REFER TO DIVISION 26 SPECIFICATIONS FOR BOX AND CONDUIT SPECIFICATIONS

AND EXECUTION REQUIREMENTS.

CAMERA BACKBOX SCHEDULE

DESCRIPTION COMMENTS

CAMERA OUTLET TERMINATION BOX:

- 6"x6"x4" BACKBOX

CAMERA MOUNT BOX:

- 4"x4"x6" BACKBOX

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-001

N O

T E

S

S Y

M B

O L S

A

B B

R E

V

IA

T

IO

N S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

TECHNOLOGY ABBREVIATIONS

& AND

@ AT

A/E ARCHITECT / ENGINEER

ACS ACCESS CONTROL SYSTEM

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISH GRADE

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

AP (WIRELESS) ACCESS POINT

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BET BUILDING ENTRANCE TERMINAL

BIDS BAGGAGE INFORMATION DISPLAY SYSTEM

BLDG BUILDING

C CONDUIT

CATV COMMUNITY ANTENNA TELEVISION

CL CENTERLINE

CLG CEILING

COAX COAXIAL

COMM COMMUNICATIONS

DSS DIGITAL SATELLITE SERVICE

DWG DRAWING

EC ELECTRICAL CONTRACTOR

EIA ELECTRONIC INDUSTRIES ALLIANCE

EMT ELECTRICAL METALLIC TUBING

ENT ELECTRICAL NONMETALLIC TUBING

EO EQUIPMENT OUTLET

ERL EXISTING TO BE RELOCATED

ERLD EXISTING - RELOCATED LOCATION

ETR EXISTING TO REMAIN

F/UTP FOILED UNSCREENED TWISTED PAIR

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FIDS FLIGHT INFORMATION DISPLAY SYSTEM

FO FIBER OPTIC

FPD FLAT-PANEL DISPLAY

GC GENERAL CONTRACTOR

GIDS GATE INFORMATION DISPLAY SYSTEM

GND GROUND

GRC GALVANIZED RIGID CONDUIT

GRS GALVANIZED RIGID STEEL

HH HAND HOLE

HVAC HEATING, VENTILATION, AIR CONDITIONING

IDF INTERMEDIATE DISTRIBUTION FRAME

IDS INTRUSION DETECTION SYSTEM

IMC INTERMEDIATE METALLIC CONDUIT

IT INFORMATION TECHNOLOGY

J-BOX JUNCTION BOX

MAX MAXIMUM

MDF MAIN DISTRIBUTION FRAME

MH MAN HOLE

MIN MINIMUM

MMFO MULTIMODE FIBER OPTIC

MNS MASS NOTIFICATION SYSTEM

MON MONITOR

MPTL MODULAR PLUG TERMINATED LINK

MTD MOUNTED

MTR MAIN TECHNOLOGY ROOM

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OFCI OWNER-FURNISHED, CONTRACTOR-INSTALLED

OFOI OWNER-FURNISHED, OWNER-INSTALLED

PA PUBLIC ADDRESS

PTZ PAN - TILT - ZOOM

PVC POLYVINYL CHLORIDE

RCV RECEIVER

REQ'D REQUIRED

ScTP SCREENED TWISTED PAIR

SE SERVICE ENTRANCE

SMFO SINGLEMODE FIBER OPTIC

SS STAINLESS STEEL

STP SHEILDED TWISTED PAIR

TBR TO BE REMOVED

TC TECHNOLOGY CONTRACTOR

TFA TO FLOOR ABOVE

TFB TO FLOOR BELOW

TGB TELECOMMUNICATIONS GROUNDING BUSBAR

TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION

TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR

TO TECHNOLOGY OUTLET

TR TECHNOLOGY ROOM

TV TELEVISION

TYP TYPICAL

UG UNDERGROUND

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTP UNSHIELDED TWISTED PAIR

VMS VIDEO MANAGEMENT SYSTEM

VSS VIDEO SURVEILLANCE SYSTEM

WL WET LOCATION LISTED

WP WEATHERPROOF

D E

S

IG

N

/2

211.56'

19.23'

.0

.0

.7

.3

150.00'

18.75' 19.03'

18.75' 18.75'

150.00'

.0

.7

.0

.0

.1

18.75' 18.75'

150.00'

.0

.6

5'

.6

5'

.6

.3

9'

.5

.5

.0

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS AND T-700 SERIES

FOR RISER DIAGRAMS.

COMMUNICATIONS

GENERAL NOTES

HH 9.601

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-100

C O

M M

U N

IC

A

T

IO

N S

S

IT

E P

L A

N

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

C h e c k e r

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.601 SEE SHEET T-102 FOR HANDHOLE PROXIMITY TO

BUILDING.

1" = 80'-0"A1

COMMUNICATIONS SITE PLAN

D E

S

IG

N

/2

C J

C J

C J

C J

C J

C J

C J

C J

C J

C J

C J

C J

CJ CJ CJCJCJ CJ CJ

CJ

CJ CJ CJ

CJ

CJ CJCJ CJ CJCJ

HH

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS AND T-700 SERIES

FOR RISER DIAGRAMS.

COMMUNICATIONS

GENERAL NOTES

43.532.82.62.321

5 6 7

T

S

R.3

R

P.9

P.3

P.2

P

N.3

N.1

N

M.4

M

L.5

L.4

L

K.2

K.1

K

J.3

J

H.1

H

G.9

G.1

G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

COMM

COMM

PSC

HAZ STOR

102A

HAZ WSTE

TOOL CRIB

SC1

STAIR

104B

KITTING

ELEC

MECH

104A

COMPOSITE

FOM STORAGE

DOCK OFFICE

LANDING GEAR SHOP

ENGINE SHOP

DOCK OFFICE

TIRE (OPEN) SHOP

SHEET METAL

DLA/IPV

COMPOSITE

HANGAR BAY

CORRIDOR

EXIT PASSAGEWAY

VEST.

CORRIDOR

VEST.

104D

TC OPEN OFF.

VEST.019

CORRIDOR

VEST.

CORRIDOR

HANGAR DOCK #1

HANGAR DOCK #2

HANGAR DOCK #3

HANGAR DOCK #4

FIRE

118A

CORRIDOR

VEST.

SB1

STAIR

MACH RM

PMD

LO STOR

E1

ELEV

BRK RM/TORNADO

SHELTER

DOCK OFFICE

VEST.

104E

AMT

WOMENS 121

MENS

JAN

TOOL CHECKOUT

104C

TC OFFICE

100A

CORRIDOR

VEST.

MENS

WOMENS

JAN

CORRIDOR

SA1

STAIR

VEST.

WELL

125B

M

125C

W

BRK RM/TORNADO

SHELTER

JAN

127D

SERVER

127A

VEST

ELEC

015A

AIR

MECH

DOCK OFFICE

FIRE

021D

CLOSET (NDI)

021A

WELL

021B

W

021C

M

MENS

WOMENS

125A

CLOSET

101A

FOM OFF.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

8'-0" 16'-0" 32'-0"

1/16" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-101

F

IR

S T

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N O

V E

R A

L L

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

D A

K

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/16" = 1'-0"A2

FIRST FLOOR COMMUNICATIONS PLAN OVERALL

D E

S

IG

N

/2

J CJ CJ CJCJCJ CJ

HH

AP

AP

AP

AP

AP

AP

STAIR

SA1

EXIT

PASSAGEWAY

HANGAR

BAY

MACH

RM

DOCK

OFFICE

ELEV

E1

CORRIDOR

118A

BRK

RM/TORNADO

SHELTER

WELL

WOMENS

MENS

CLOSET

125A

M

125B

W

125C

COMM

FIRE

ELEC

MECH

T-401

G8

POINT OF ENTRY FOR FIBER OPTIC

AND COPPER CABLES RUN FROM

CENTRAL UTILITY PLANT BUILDING

T-401G6

T-401

H5

43.532.82.62.321

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1

N

M.4

M

L.5

L.4

L

K.2

K

J.3

H6

F9

D6

PMD

127SERVER

127D

LO STOR

STAIR

SB1

9.705

9.706

9.704

9.704 T-404

E7 T-404

G5

T-404E5

G7

E9

D7

9.709

9.708

9.708

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL TECHNOLOGY OUTLETS ON THIS SHEET TERMINATE

IN COMM ROOM 114.

COMMUNICATIONS

GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-102

F

IR

S T

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N A

R E

A A

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.704 12" X 4" BASKET CABLE TRAY MOUNTED AT 10'-9"

AFF.

9.705 (2) 4 INCH UNDERGROUND CONDUITS FOR

TECHNOLOGY BACK BONE CABLES.

9.706 (2) 4 INCH CONDUITS WITH HANDHOLE FOR

INCOMING TECHNOLOGY SERVICE.

9.708 CABLE TRAY PENETRATION TO BE STORM SHELTER

RATED.

9.709 (2) 4" CONDUITS AT 10'-9" FOR SECURE PERIMETER

PENETRATION

1/8" = 1'-0"A1

FIRST FLOOR COMMUNICATIONS PLAN - AREA A

D E

S

IG

N

/2

C J

CJ

CJ

CJ CJ CJ

CJ

AP

AP

AP

AP

AP

HANGAR

BAY

CORRIDOR

VEST.

DLA/IPV

COMPOSITE

MENS

WOMENS

CORRIDOR

019VEST.

JAN

VEST.

BRK

RM/TORNADO

SHELTER

CLOSET

(NDI)

021D

M

021C

W

021B

WELL

021A

AIR

015A

ELEC

MECH

COMM

FIRE

DOCK

OFFICE

T-402

E7 T-402E5T-402

G5

5 6 7

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1 N

M.4

M

L.5

L.4

L

K.2

K.1 K

J.3

J

G7

E9

C7

9.704

9.704

9.705

9.708

9.708

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL TECHNOLOGY OUTLETS ON THIS SHEET TERMINATE

IN COMM ROOM 014.

COMMUNICATIONS

GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-103

F

IR

S T

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N A

R E

A B

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

D e s ig n e r

A u th o r

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.704 12" X 4" BASKET CABLE TRAY MOUNTED AT 10'-9"

AFF.

9.705 (2) 4 INCH UNDERGROUND CONDUITS FOR

TECHNOLOGY BACK BONE CABLES.

9.708 CABLE TRAY PENETRATION TO BE STORM SHELTER

RATED.

1/8" = 1'-0"A1

FIRST FLOOR COMMUNICATIONS PLAN - AREA B

D E

S

IG

N

/2

C J

C J

C J

C J

C J

C J

C J

C J

CJ CJCJ CJ CJCJ

AP

AP

AP

AP

AP

AP

43.532.82.62.321

J.3

J

H.1

H

G.9

G.1

G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

PSC

HAZ STOR

102A

HAZ WSTE

TOOL CRIB

SC1

STAIR

104B

KITTING

104A

COMPOSITE

FOM STORAGE

DOCK OFFICE

CORRIDOR

104D

TC OPEN OFF.

HANGAR DOCK #4

104E

AMT

TOOL CHECKOUT

104C

TC OFFICE

100A

CORRIDOR

VEST.

101A

FOM OFF.

9.704

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL TECHNOLOGY OUTLETS ON THIS SHEET TERMINATE

IN COMM ROOM 114.

COMMUNICATIONS

GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-104

F

IR

S T

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N A

R E

A C

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

D e s ig n e r

A u th o r

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.704 12" X 4" BASKET CABLE TRAY MOUNTED AT 10'-9"

AFF.

1/8" = 1'-0"A1

FIRST FLOOR COMMUNICATIONS PLAN - AREA C

D E

S

IG

N

/2

AP

AP

AP

AP

AP

5 6 7

J

H.1

H G.9

G.1 G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

CORRIDOR

DOCK

OFFICE

WOMENS

MENS

JAN

SHEET

METAL

TIRE

(OPEN)

SHOP

ENGINE

SHOP

LANDING

GEAR

SHOP

CORRIDOR

VEST.

HANGAR

BAY

9.704

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL TECHNOLOGY OUTLETS ON THIS SHEET TERMINATE

IN COMM ROOM 014.

COMMUNICATIONS

GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-105

F

IR

S T

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N A

R E

A D

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

D e s ig n e r

A u th o r

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.704 12" X 4" BASKET CABLE TRAY MOUNTED AT 10'-9"

AFF.

1/8" = 1'-0"A1

FIRST FLOOR COMMUNICATIONS PLAN - AREA D

D E

S

IG

N

/2

F F

AP

AP

C J

C J

C J

C J

C J

C J

C J

C J

F

AP

AP

AMXS

CONF

218J

CONF

218I

COPY

218H

STAIR

SA1

OFFICE

218G

OFFICE

218F

OFFICE

218D

OFFICE

218E

OFFICE

218C

OFFICE

218B

OFFICE

218A

ELEC

218K

ELEV

E2

CORRIDOR

BRK

SCHED

OFF

WOMENS

MENS

MECH

CTR

TRNG

OFFICE

209B OFFICE

209A ELEC

43.532.82.62.321

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1 N

M.4

M

L.5

L.4

L

K.2

K.1 K

J.3

J

STOR

HANGAR

BAY

OFFICE

202F

COPY/FILE

202G

OFFICE

202H

OFFICE

202I

OFFICE

202J

OPEN

OFFICE

OFFICE

202E

OFFICE

202D

OFFICE

202C

OFFICE

202B

ELEC

202A

STAIR

SC2

COMM

COLLAB

202K

CTR

TRNG

RECYCLING

OPEN

OFFICE

T-403

F8

T-403F6

T-403

H6

9.704

43.532.82.62.321

J

H.1

H G.9

G.1 G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

H8

F10

D8

SFTWR

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL TECHNOLOGY OUTLETS ON THIS SHEET TERMINATE

IN COMM ROOM 204.

COMMUNICATIONS

GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-106

S E

C O

N D

F L O

O R

C O

M M

U N

IC

A

T

IO

N S

P L A

N

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.704 12" X 4" BASKET CABLE TRAY MOUNTED AT 10'-9"

AFF.

1/8" = 1'-0"A1

SECOND FLOOR COMMUNICATIONS PLAN - AREA A

1/8" = 1'-0"A6

SECOND FLOOR COMMUNICATIONS PLAN - AREA C

D E

S

IG

N

/2

ACD

A

C D

ACD

A C

D

CR

C R

CR

CR

C R

F

F

CR

ACD

ACD

PMD

STAIR

SA1

EXIT

PASSAGEWAY

SERVER

127D

HANGAR

BAY

LO STOR

MACH

RM

DOCK

OFFICE

ELEV

E1

CORRIDOR

118A

BRK

RM/TORNADO

SHELTER

WELL

124 WOMENS

MENS

CLOSET

125A

M

125B

W

125C

COMM

FIRE

ELEC

MECH

NOTE TO REVIEWER: THE PROJECT WILL PROVIDE ROUGH IN INSTALLATION

FOR ACCESS CONTROL SYSTEM PROVIDED AND INSTALLED BY OTHERS.

ROUGH IN FOR ACCESS CONTROL AND SURVEILLANCE CAMERAS WILL OCCUR

AT ENTRANCES AND SECURE AREAS.

43.532.82.62.321

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1 N

M.4

M

L.5

L.4

L

K.2

K.1 K

J.3

J

VEST

127A

STAIR

SB1

JAN

VEST.

CAM-01

CAM-EX-01

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600

SERIES FOR SCHEDULES, AND T-700 SERIES FOR

RISER DIAGRAMS.

3. ALL SECURITY DEVICES ON THIS SHEET

TERMINATE IN COMM ROOM 114

SECURITY GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-121

F

IR

S T

F L O

O R

S E

C U

R

IT

Y P

L A

N A

R E

A A

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR SECURITY PLAN AREA A

D E

S

IG

N

/2

C J

CJ

CJ

CJ CJ CJ

CJ

A C

D A

C D

C R

C R

C R

C R

C R

C R

C R

C R

F

A C

D A

C D

A C

D A

C D

A C

D A

C D

DLA/IPV

COMPOSITE

MENS

WOMENS

CORRIDOR

VEST.

JAN

VEST.

BRK

RM/TORNADO

SHELTER

CLOSET

(NDI)

021D

M

021C

W

021B

WELL

021A

ELEC

AIR

015A

MECH

COMM

DOCK

OFFICE

5 6 7

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1 N

M.4

M

L.5

L.4

L

K.2

K.1 K

J.3

J

CORRIDOR

VEST.

HANGAR

BAY

FIRE

CAM-02

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600

SERIES FOR SCHEDULES, AND T-700 SERIES FOR

RISER DIAGRAMS.

3. ALL SECURITY DEVICES ON THIS SHEET

TERMINATE IN COMM ROOM 014

SECURITY GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-122

F

IR

S T

F L O

O R

S E

C U

R

IT

Y P

L A

N A

R E

A B

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR SECURITY PLAN AREA B

D E

S

IG

N

/2

C J

C J

C J

C J

C J

C J

C J

C J

CJ CJCJ CJ CJCJ

A C

D C

R C

R C

R C

R

F

F

A C

D A

C D

A C

D

PSC

107 DOCK

OFFICE

CORRIDOR

TOOL

CRIB

TC

OFFICE

104C

TOOL

CHECKOUT

HAZ

STOR

COMPOSITE

104A

HAZ

WSTE

102A

FOM

STORAGE

CORRIDOR

100A

43.532.82.62.321

J.3

J

H.1

H G.9

G.1 G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

TC

OPEN

OFF.

104D

FOM

OFF.

101A

KITTING

104B

AMT

104E

VEST.

STAIR

SC1

CAM-EX-02

CAM-03

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600

SERIES FOR SCHEDULES, AND T-700 SERIES FOR

RISER DIAGRAMS.

3. ALL SECURITY DEVICES ON THIS SHEET

TERMINATE IN COMM ROOM 114

SECURITY GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-123

F

IR

S T

F L O

O R

S E

C U

R

IT

Y P

L A

N A

R E

A C

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR SECURITY PLAN AREA C

D E

S

IG

N

/2

A

D C

R C

R C

R C

R C

R C

R

F

F

C R

A C

D A

C D

A C

D A

C D

A C

D

LANDING

GEAR

SHOP

ENGINE

SHOP

TIRE

(OPEN)

SHOP

SHEET

METAL

MENS

009 WOMENS

DOCK

OFFICE

CORRIDOR

CORRIDOR

5 6 7

J

H.1

H G.9

G.1

G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

CAM-04

CAM-EX-03

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600

SERIES FOR SCHEDULES, AND T-700 SERIES FOR

RISER DIAGRAMS.

3. ALL SECURITY DEVICES ON THIS SHEET

TERMINATE IN COMM ROOM 014

SECURITY GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-124

F

IR

S T

F L O

O R

S E

C U

R

IT

Y P

L A

N A

R E

A D

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR SECURITY PLAN AREA D

D E

S

IG

N

/2

STAIR

SA1

EXIT

PASSAGEWAY

HANGAR

BAY

MACH

RM

DOCK

OFFICE

119ELEV

E1

CORRIDOR

118A

BRK

RM/TORNADO

SHELTER

WELL

WOMENS

MENS

CLOSET

125A

M

125B

W

125C

COMM

FIRE

MECH

NOTE TO REVIEWER: THE PROJECT WILL PROVIDE ROUGH IN INSTALLATION

FOR AUDIO VISUAL SYSTEMS PROVIDED AND INSTALLED BY OTHERS.

ROUGH IN FOR AV WILL OCCUR IN CONFERENCE ROOMS, CORRIDORS AND

OFFICES AS REQUIRED.

43.532.82.62.321

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1 N

M.4

M

L.5

L.4

L

K.2

K.1 K

J.3

J

ELEC

AIR

STAIR

SB1

VEST.

PMD

SERVER

127D

LO STOR

LO STOR

VEST.

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

AUDIOVISUAL GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-141

F

IR

S T

F L O

O R

A U

D

IO

V

IS

U A

L P

L A

N A

R E

A A

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR AUDIO VISUAL PLAN AREA A

D E

S

IG

N

/2

C J

CJ

CJ

CJ CJ CJ

CJ

5 6 7

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1 N

M.4

M

L.5

L.4

L

K.2

K.1 K

J.3

J

DLA/IPV

COMPOSITE

HANGAR BAY

VEST.

CORRIDOR

VEST.

CORRIDOR

HANGAR DOCK #1

VEST.

BRK RM/TORNADO

SHELTER

JAN

ELEC

015A

AIR

MECH

DOCK OFFICE 013

FIRE

COMM

021A

WELL

021B

W

021C

M

MENS

WOMENS

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL DISPLAY CABLING TO TERMINATE IN COMM RM. 014.

AUDIOVISUAL GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-142

F

IR

S T

F L O

O R

A U

D

IO

V

IS

U A

L P

L A

N A

R E

A B

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR AUDIO VISUAL PLAN AREA B

D E

S

IG

N

/2

C J

C J

C J

C J

C J

C J

C J

C J

CJ CJCJ CJ CJCJ

43.532.82.62.321 J.3

J

H.1

H G.9

G.1 G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

PSC

HAZ

STOR

HAZ

WSTE

102A

TOOL

CRIB

STAIR

SC1

KITTING

104B

COMPOSITE

104A

FOM

STORAGE

DOCK

OFFICE

CORRIDOR

TC

OPEN

OFF.

104D

HANGAR

DOCK #4

AMT

104E

TOOL

CHECKOUT

TC

OFFICE

104C

CORRIDOR

100A

VEST.

FOM

OFF.

101A

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL DISPLAY CABLING TO TERMINATE IN COMM RM. 014.

AUDIOVISUAL GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-143

F

IR

S T

F L O

O R

A U

D

IO

V

IS

U A

L P

L A

N A

R E

A C

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR AUDIO VISUAL PLAN AREA C

D E

S

IG

N

/2

5 6 7

H.1

H G.9

G.1 G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

DOCK

OFFICE

WOMENS

MENS

JAN

CORRIDOR

SHEET

METAL

TIRE

(OPEN)

SHOP

ENGINE

SHOP

LANDING

GEAR

SHOP

CORRIDOR

HANGAR

BAY

HANGAR

DOCK #2

HANGAR

BAY

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL DISPLAY CABLING TO TERMINATE IN COMM RM. 014.

AUDIOVISUAL GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-144

F

IR

S T

F L O

O R

A U

D

IO

V

IS

U A

L P

L A

N A

R E

A D

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR AUDIO VISUAL PLAN AREA D

D E

S

IG

N

/2

C J

C J

C J

C J

C J

C J

C J

C J

CJ CJCJ CJ CJCJ

AMXS

CONF

218J

CONF

218I

COPY

218H

STAIR

SA1

OFFICE

218G

OFFICE

218F

OFFICE

218D

OFFICE

218E

OFFICE

218C

OFFICE

218B

OFFICE

218A

ELEC

218K

ELEV

E2

CORRIDOR

BRK

SCHED

OFF

WOMENS

MENS

MECH

CTR

TRNG

OFFICE

209B

OFFICE

209A

ELEC

43.532.82.62.321

T

S

R.3

R P.9

P.3 P.2

P

N.3

N.1 N

M.4

M

L.5

L.4

L

K.2

K.1 K

J.3

J

COMMAND

SUITE

214C

DEPUTY

214B

RECEPTION

DEPUTY

214A

STOR

W

M

HANGAR

BAY

OFFICE

202F

COPY/FILE

202G

OFFICE

202H

OFFICE

202I

OFFICE

202J

OFFICE

202E

OFFICE

202D

OFFICE

202C

OFFICE

202B

ELEC

202A

STAIR

SC2

COMM

SFTWR

203COLLAB

202K

CTR

TRNG

OPEN

OFFICE

43.532.82.62.321

J

H.1

H G.9

G.1 G

F.8

F

E.8

E.7

E

D.8

D.7

D

C.8

C.6

C

B.4

B

A

OPEN

OFFICE

1. REFER TO T-001 FOR NOTES, SYMBOLS, AND

ABBREVIATIONS.

2. REFER TO T-500 SERIES FOR DETAILS, T-600 SERIES FOR

SCHEDULES, AND T-700 SERIES FOR RISER DIAGRAMS.

3. ALL TV DEVICES ON THIS SHEET TERMINATE IN COMM

ROOM 204.

AUDIOVISUAL GENERAL NOTES

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-145

S E

C O

N D

F L O

O R

A U

D

IO

V

IS

U A

L P

L A

N

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

SECOND FLOOR AUDIO VISUAL PLAN AREA A

1/8" = 1'-0"A6

SECOND FLOOR AUDIO VISUAL PLAN AREA C

D E

S

IG

N

/2

BET

TMGB

9.701

9.801

F

F

COMM

9.703

9.707

9.707

COMM

9.702

9.702

EQUIPMENT SCHEDULE

## EQUIPMENT DESCRIPTION

01 HORIZONTAL GROUND BUS BAR

NOTES:

1. EQUIPMENT LOCATION IS SHOWN TO ILLUSTRATE INTENT. COORDINATE ACTUAL

LOCATION WITHIN RACK WITH OWNER PRIOR TO INSTALLATION.

2. EQUIPMENT IS SHOWN FOR REFERENCE ONLY. ACTUAL QUANTITIES WILL BE BASED

ON EQUIPMENT OUTLETS INSTALLED.

3. REFER TO DIVISION 27 SPECIFICATIONS FOR EQUIPMENT CABINET REQUIREMENTS.

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

TO TMGB/TGB

EQUIPMENT RACK (TYPICAL)

1.75" RACK UNITS (RU)

FLOOR

0'-3"

W A

L L

TO TMGB/TGB

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-401

E N

L A

R G

E D

P L A

N S

E

L E

V A

T

IO

N S

S

E C

T

IO

N S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.702 12" X 1.5" CABLE LADDER RACK.

9.703 4' X 8' FIRE RATED PLYWOOD MOUNTED VERTICALLY

WITH BOTTOM AT 6" AFF. TYPICAL ON ALL WALLS.

9.707 SECURITY WALL CABINET.

9.801 SPACE RESERVED FOR ACCESS CONTROL PANEL.

1/4" = 1'-0"G8

ENLARGED PLAN - COMM ROOM 114

1/4" = 1'-0"G6

SOUTH WALL - COMM ROOM 114

1/4" = 1'-0"H5

CABLE RUNWAY LAYOUT - COMM ROOM 114

NO SCALEA1

RACK ELEVATIONS - COMM 114

1/4" = 1'-0"F9

NORTH WALL - COMM ROOM 114

1/4" = 1'-0"D6

EAST WALL - COMM ROOM 114

1/4" = 1'-0"H6

WEST WALL - COMM ROOM 114

D E

S

IG

N

/2

F

F

9.801

9.703

COMM

9.707

9.707

9.702

9.702

EQUIPMENT SCHEDULE

## EQUIPMENT DESCRIPTION

01 HORIZONTAL GROUND BUS BAR

NOTES:

1. EQUIPMENT LOCATION IS SHOWN TO ILLUSTRATE INTENT. COORDINATE ACTUAL

LOCATION WITHIN RACK WITH OWNER PRIOR TO INSTALLATION.

2. EQUIPMENT IS SHOWN FOR REFERENCE ONLY. ACTUAL QUANTITIES WILL BE BASED

ON EQUIPMENT OUTLETS INSTALLED.

3. REFER TO DIVISION 27 SPECIFICATIONS FOR EQUIPMENT CABINET REQUIREMENTS.

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

TO TMGB/TGB

EQUIPMENT RACK (TYPICAL)

1.75" RACK UNITS (RU)

FLOOR

0'-3"

W A

L L

TO TMGB/TGB

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-402

E N

L A

R G

E D

P L A

N S

E

L E

V A

T

IO

N S

S

E C

T

IO

N S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.702 12" X 1.5" CABLE LADDER RACK.

9.703 4' X 8' FIRE RATED PLYWOOD MOUNTED VERTICALLY

WITH BOTTOM AT 6" AFF. TYPICAL ON ALL WALLS.

9.707 SECURITY WALL CABINET.

9.801 SPACE RESERVED FOR ACCESS CONTROL PANEL.

1/4" = 1'-0"E7

ENLARGED PLAN - COMM 014

1/4" = 1'-0"E5

SOUTH WALL - COMM 014

1/4" = 1'-0"G5

COMM 014 CABLE LADDER PLAN

NO SCALEA1

RACK ELEVATIONS - COMM 014

1/4" = 1'-0"G7

WEST WALL - COMM 014

1/4" = 1'-0"C7

EAST WALL - COMM 014

1/4" = 1'-0"E9

NORTH WALL - COMM 014

D E

S

IG

N

/2

TGB

COMM

9.707

9.707

EQUIPMENT SCHEDULE

## EQUIPMENT DESCRIPTION

01 HORIZONTAL GROUND BUS BAR

NOTES:

1. EQUIPMENT LOCATION IS SHOWN TO ILLUSTRATE INTENT. COORDINATE ACTUAL

LOCATION WITHIN RACK WITH OWNER PRIOR TO INSTALLATION.

2. EQUIPMENT IS SHOWN FOR REFERENCE ONLY. ACTUAL QUANTITIES WILL BE BASED

ON EQUIPMENT OUTLETS INSTALLED.

3. REFER TO DIVISION 27 SPECIFICATIONS FOR EQUIPMENT CABINET REQUIREMENTS.

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

TO TMGB/TGB

EQUIPMENT RACK (TYPICAL)

1.75" RACK UNITS (RU)

FLOOR

0'-3"

W A

L L

TO TMGB/TGB

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-403

E N

L A

R G

E D

P L A

N S

E

L E

V A

T

IO

N S

S

E C

T

IO

N S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

M J R

D A

K

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.707 SECURITY WALL CABINET.

1/4" = 1'-0"F8

ENLARGED FLOOR PLAN - COMM ROOM 204

1/4" = 1'-0"F6

SOUTH WALL - COMM 204

1/4" = 1'-0"H6

CABLE RUNWAY PLAN - COMM ROOM 204

NO SCALEA1

RACK ELEVATIONS - COMM 204

1/4" = 1'-0"D8

EAST WALL - COMM 204

1/4" = 1'-0"F10

NORTH WALL - COMM 204

1/4" = 1'-0"H8

WEST WALL - COMM 204

D E

S

IG

N

/2

SERVER

127D

F

F

9.703

SERVER

127D

9.702

9.702

EQUIPMENT SCHEDULE

## EQUIPMENT DESCRIPTION

01 HORIZONTAL GROUND BUS BAR

NOTES:

1. EQUIPMENT LOCATION IS SHOWN TO ILLUSTRATE INTENT. COORDINATE ACTUAL

LOCATION WITHIN RACK WITH OWNER PRIOR TO INSTALLATION.

2. EQUIPMENT IS SHOWN FOR REFERENCE ONLY. ACTUAL QUANTITIES WILL BE BASED

ON EQUIPMENT OUTLETS INSTALLED.

3. REFER TO DIVISION 27 SPECIFICATIONS FOR EQUIPMENT CABINET REQUIREMENTS.

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

V E

R T

IC

A

L C

A B

L E

M A

N A

G E

R S

F

R O

N T

A N

D R

E A

R

TO TMGB/TGB

EQUIPMENT RACK (TYPICAL)

1.75" RACK UNITS (RU)

FLOOR

0'-3"

W A

L L

TO TMGB/TGB AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-404

E N

L A

R G

E D

P L A

N S

E

L E

V A

T

IO

N S

S

E C

T

IO

N S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

M J R

D A

K

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

KEYED NOTES

9.702 12" X 1.5" CABLE LADDER RACK.

9.703 4' X 8' FIRE RATED PLYWOOD MOUNTED VERTICALLY

WITH BOTTOM AT 6" AFF. TYPICAL ON ALL WALLS.

1/4" = 1'-0"E7

ENLARGED PLAN - SERVER 127D

1/4" = 1'-0"G5

CABLE RUNWAY LAYOUT - SERVER 127D

1/4" = 1'-0"G7

NORTH WALL - SERVER 127D

1/4" = 1'-0"D7

SOUTH WALL - SERVER 127D

1/4" = 1'-0"E9

EAST WALL - SERVER 127D

1/4" = 1'-0"E5

WEST WALL - SERVER 127D

NO SCALEA1

RACK ELEVATIONS - SERVER 127D

D E

S

IG

N

/2

I.D.

I.D.

I.D.

I.D. ADHESIVE LABEL

(TYPICAL)

MOUNTING LUG

(1 OF 2)

SYMBOL(S)

W

SINGLE-PORT TECHNOLOGY OUTLET

FOR WALL-MOUNTED PHONE

I.D.

I.D.

I.D.

SINGLE-PORT

TECHNOLOGY OUTLET

TWO-PORT

TECHNOLOGY OUTLET

FOUR-PORT

TECHNOLOGY OUTLET

SYMBOL(S)

CA EQ

SYMBOL(S) SYMBOL(S)

AP

I.D.

I.D.

SYMBOL(S)

TV

TWO-PORT TECHNOLOGY

OUTLET FOR TELEVISION

KEY:

8P8C MODULAR JACK

COAXIAL F-COUPLER

NOTES:

1. REFER TO DIVISION 27 SPECIFICATIONS FOR PERFORMANCE, PIN/PAIR ASSIGNMENTS, MATERIAL, AND COLOR.

FP

HDMI PORT

COMMUNICATIONS AND OTHER

LOW-VOLTAGE CABLE

CURVED CABLE

SADDLE

NOTES:

1. SUPPORT SPACING: 48" MAX.

2. CABLE SAG AT MIDPOINT: 6" MAX.

3. CABLE RETENTION CLIP SHOWN IS TYPICAL. OTHER DESIGNS

ARE ACCEPTABLE PER DIVISION 26 SPECIFICATIONS.

CABLE

RETENTION

CLIP

SUPPORT SPACING

CABLE SUPPORT

HOOK

ANCHOR HOOKS PER

DIVISIONS 26

CABLE SAG

AT MIDPOINT

CABLE SUPPORT

HOOK DETAIL

NOTES:

1. REFER TO DIVISION 27 SPECIFICATIONS AND DRAWINGS

FOR SIZE AND LOCATION OF CABLE RUNWAY.

2. PROPER ORIENTATION OF CABLE RUNWAY POSITIONS

CROSS MEMBERS (SLATS) AT TOP OF STRINGERS.

3. PROVIDE CABLE WATERFALL INTO VERTICAL CABLE

MANAGER(S) FROM CABLE RUNWAY.

SECURE MOUNTING PLATE TO EQUIPMENT RACK

PER MANUFACTURERS RECOMMENDATIONS.

EQUIPMENT RACK NOT SHOWN.

CABLE RUNWAY ELEVATION KIT (TYPICAL)

CABLE RUNWAY

NOTES:

1. REFER TO DIVISION 27 SPECIFICATIONS AND DRAWINGS

FOR SIZE AND LOCATION OF CABLE RUNWAY.

2. PROPER ORIENTATION OF CABLE RUNWAY POSITIONS

CROSS MEMBERS (SLATS) AT TOP OF STRINGERS.

SECURE BRACKET TO WALL

PER MANUFACTURERS

RECOMMENDATIONS

CABLE RUNWAY

TRAPEZE SUPPORT

NOTES:

1. REFER TO DIVISION 27 SPECIFICATIONS FOR TRAY SPACING AND

OTHER INSTALLATION REQUIREMENTS.

2. SEE DRAWINGS FOR CABLE TRAY WIDTH(S) AND DEPTH(S).

3. ANCHOR THREADED ROD TO STEEL WITH BEAM CLAMPS OR USING

STEEL DROP-IN ANCHORS. PLASTIC OR LEAD TYPE ANCHORS ARE

NOT APPROVED.

4. COORDINATE WITH OTHER TRADES TO MAINTAIN MINIMUM

CLEARANCE OF 1'-0" ON BOTH SIDES OF THE TRAY AND 0'-8" ABOVE

TOP OF THE TRAY.

5. PROVIDE ALL ANGLES, TEE'S, CROSSES, SPLICES, ACCESSORIES,

ETC. AS REQUIRED.

6. PROVIDE OFFSETS AS REQUIRED TO CHANGE ELEVATIONS AS

OBSTRUCTIONS DICTATE. WHERE CABLE TRAY CONTINUITY

CANNOT BE MAINTAINED, PROVIDE STRAP BONDED TO ADJACENT

TRAY SECTIONS.

7. MAINTAIN MINIMUM SEPARATION DISTANCES FROM <480V POWER

LINES AS FOLLOWS:

A. 12" FROM POWER LINES OF <5KVA

B. 18" FROM HIGH VOLTAGE LIGHTING (INCL. FLUORESCENT)

C. 39" FROM POWER LINES OF 5KVA OR GREATER

D. 39" FROM TRANSFORMERS AND MOTORS

8. PROVIDE RADIUSED DROP-OUT AT LOCATIONS WHERE CABLE EXITS

THE TRAY.

THREADED ROD

12" TRAY - 3/8" ATR

>12" TRAY - 1/2" ATR

PLASTIC SLEEVE

(~6-INCH LENGTH)

STRUT OR

MANUFACTURER-

SUPPLIED HANGER

WALL BRACKET

MANUFACTURER-

SUPPLIED WALL

BRACKET

CABLE TRAY

(TYPICAL)

RATED WALL

(EQUIPMENT ROOM SIDE;

TYPICAL)

PROVIDE THROUGH PENETRATION

FIRESTOP SYSTEM AS SPECIFIED.

PROVIDE MANUFACTURED

RADIUS DROPOUTS (BOTH

SIDES OF PENETRATION)

CABLE RUNWAY

INSIDE

EQUIPMENT

ROOM (TYPICAL)

NOTES:

1. REFER TO DIVISION 7 SPECIFICATION FOR FIRESTOP REQUIREMENTS.

2. FIRE SYSTEMS SHALL MAINTAIN RATING OF WALL.

PATCH CORD(S) BY OWNER

OWNER-PROVIDED

WIRELESS ACCESS POINT

BOX SUPPORT HANGER

BY DIVISION 26

SUSPENDED CEILING

OUTLET BOX WITH SINGLE-GANG

COVER (MUD RING) AND BLANK COVER

PLATE BY DIVISION 26. REFER TO T-001

FOR OUTLET BOX INFORMATION.

COMMUNICATIONS CABLE(S)

BY DIVISION 27

PROVIDE GROMMET AS

REQUIRED

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

US Army Corps of Engineers

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

Mead & Hunt, Inc.

2440 Deming Way

Middleton, WI 53562 phone: 608-273-6380 meadhunt.com T-501

D E

T A

IL

S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

E J G

E J G

J R

W

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

G8

TECHNOLOGY OUTLET CONFIGURATIONS

E8

TECHNOLOGY OUTLET PATHWAY - J-HOOKS

G4

CABLE RUNWAY - RACK-MOUNT

D4

CABLE RUNWAY - WALL BRACKET

B8

CABLE TRAY

B4

WALL PENETRATION - FIRESTOP

D E

S

IG

N

/2

/2

G1

WIRELESS ACCESS POINT MOUNTING

INTRA-BUILDING, & INTER BUILDING

BACKBONE…