WWYK263009_65 Drawings_Volume 1_Part6_Part2.pdf
PDF 6 MB Posted
- Solicitation number
- W912BV25S0014
About this file
These are architectural drawings depicting reflected ceiling plans and air barrier building sections for a Bomber Agile Common Hangar project at Tinker Air Force Base. The drawings show detailed plans for a large hangar facility with administrative, shop, and hangar bay areas, including specifications for air barrier systems, ceiling types, lighting fixtures, and control joints.
The drawings indicate the hangar has significant square footage requirements, with the administrative area having 6,670 SF of walls, 2,151 SF of glazing, and 24,058 SF of roofing, while the hangar bay has 101,616 SF of walls, 25,560 SF of glazing, and 148,916 SF of roofing. The facility includes multiple ceiling types including acoustical ceiling tiles and gypsum wallboard, with ceiling heights generally at 10'-0" above finished floor. The drawings contain extensive technical details about lighting placement, HVAC diffusers, access panels, and other ceiling-mounted equipment. Air barrier details show careful attention to sealing penetrations and material transitions within air barrier boundaries to ensure proper building envelope performance.
View the file
Other files
Show 40 more
Latest 50 of 95 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND:
AIR BARRIER INSPECTION
AND TESTING
AIR BARRIER INSPECTION
ONLY
AREAS OUTSIDE OF THE AIR
BARRIER
AIR BARRIER LOCATION AT
MEMBRANES/FLASHING
OTHER BUILDING
ELEMENTS ACTING AS AIR
BARRIER
OTHER BUILDING
ELEMENTS
ADMINISTRATIVE HANGAR BAY SHOPS
WALLS 6,670 SF 101,616 SF 15,658 SF
GLAZING 2,151 SF 25,560 SF 120 SF
DOORS 1,412 SF 34,705 SF 2,246 SF
ROOFING 24,058 SF 148,916 SF 16,375 SF
NOTE: BTM PORTION OF HANGAR WALLS CALCULATED
WITHIN ADMINISTRATIVE OR SHOP TESTING AREAS
RESPECTIVELY.
SIX-SIDED AREA OF THE AIR BARRIER ENVELOPE:
GENERAL NOTES (AIR BARRIER):
1. SEAL ALL AIR BARRIER PENETRATIONS WITH AIR
BARRIER FLASHING & CAULK.
2. REFER TO DETAIL SHEETS FOR MATERIAL
TRANSITIONS WITHIN AIR BARRIER BOUNDARIES.
FIRST FLOOR
100'-0"
HANGAR DOOR
99'-2"
SECOND FLOOR
118'-1"
ADMIN. ROOF
135'-0"
HANGAR ROOF RIDGE
210'-2"
HANGAR DOOR HEAD
161'-5"
F1
A-113
HANGAR ROOF
190'-2"
1.5 3
G1
A-303
2.3
A1
A-303
1 2.9
5.8
3.9
D1
A-302
FIRST FLOOR
100'-0"
HANGAR DOOR
99'-2"
SECOND FLOOR
118'-1"
ADMIN. ROOF
135'-0"
HANGAR ROOF RIDGE
210'-2"
A1
A-113
HANGAR DOOR HEAD
161'-5"
HANGAR ROOF
190'-2"
T ABCDEFGHJKLMNRR.3 P.2S R.5 M.1 L.3 J.9R.9
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
8'-0" 16'-0" 32'-0"
1/16" = 1'-0"
A-113
A
IR
B A
R R
IE
R
B U
IL
D
IN
G
S E
C T
IO
N
S
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
K B
L A
N D
F O
R D
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/16" = 1'-0"A1
BUILDING SECTION - AIR BARRIER
1/16" = 1'-0"F1
BUILDING SECTION - AIR BARRIER
D E
S
IG
N
/2
/2
T
A
B
C
D
E
F
G
H
K
L
M
N
P
R
542 71.5 2.8
R.3
P.3
M.4
N.3
L.5
K.2
G.9
F.8
E.7
C.6
D.7
S
32.31 2.9
R.5
M.1
5.83.9
J.9
R.9
PSC
HAZ STOR
HAZ WSTE
102A
TOOL CRIB
STAIR
SC1
KITTING
104B
AIR
ELEC
MECH
COMPOSITE
104A
FOM STORAGE
DOCK OFFICE
LANDING GEAR SHOP
ENGINE SHOP
DOCK OFFICE
TIRE (OPEN) SHOP
SHEET METAL
DLA/IPV
COMPOSITE
HANGAR BAY
EXIT PASSAGEWAY
CORRIDOR
CORRIDOR
VEST.
CORRIDOR
VEST.
VEST.
BRK RM/TORNADO
SHELTER
FIRE
COMM
BRK RM/TORNADO
SHELTER
WELL
DOCK OFFICE
PMD
LO STOR
ELEV
E1
STAIR
SB1
T O
O L
C H
E C
K O
U T
CORRIDOR
100A
VEST.
SERVER
127D
VEST.
CORRIDOR
118A
M
W
WOMENS
MENS
VEST.
JAN
AIR
015A
ELEC
COMM
MECH
DOCK OFFICE
FIRE
CORRIDOR
TC OFFICE
104C
VEST.
MENS
WOMENS
M
021C
W
021B
WELL
021A
MENS
WOMENS
TC OPEN OFF.
104D
STAIR
SA1
CORRIDOR
VEST.
CLOSET
AMT
104E
1'
-0
/8
F10
C10
FOM OFF.
101A
HANGAR DOCK #3
HANGAR DOCK #4
HANGAR DOCK #2
HANGAR DOCK #1
3' -4
'-0
0'
-8
2' -0
'-0
'-0
'-8
'-0
9'
-8
1/ 4"
JAN
JAN
CLOSET
(NDI)
021D
VEST
127A
3'
-1
3/ 4"
5' -4
'-0
7' -8
8'
-0
8' -0
8'
-0
'-0
8'
-0
9' -8
'-0
5' -4
'-0
'-0
'-0
9' -0
'-0
4' -4
MACH RM
7'
-9
6'
-2
/2
50'-0"
'-0
'-0
7' -0
8'
-0
'-0
7'
-0
7' -0
'-0
7' -0
7'
-0
'-0
7'
-0
7' -0
'-0
8' -0
9'
-0
8' -0
8'
-0
'-0
'-0
'-0
'-0
8' -0
8'
-0
'-0
'-0
8' -0
8'
-0
'-0
8'
-0
8' -0
8'
-0
8' -0
'-0
'-0
'-0
'-0
6'
-0
7' -4
'-4
4' -0
2'-0" 9'-0" 9'-0" 10'-0" 9'-0" 9'-0" 2'-0"
2'-0" 9'-0" 9'-0" 10'-0" 9'-0" 9'-0" 2'-0"
2'-0" 9'-0" 9'-0" 10'-0" 9'-0" 9'-0" 2'-0"
CJ
CJ
CJ
CJ
2'-0"
FLOOR PLAN GENERAL NOTES
1. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.
2. DIMENSIONS SHOWN ARE LOCATED TO EDGE OF SLAB,
EDGE OF CURB, CENTER LINE OF COLUMNS, FACE OF
STUD, UNO.
3. DIMENSIONS MARKED AS "CLR" DICTATES THE CLEAR
DIMENSION FROM FINISH TO FINISH
4. APPROVED FIRE EXTINGUISHERS MUST BE FURNISHED
AND INSTALLED BY G.C. AS REQUIRED BY LOCAL
AUTHORITY.
5. PROVIDE & INSTALL BROWN PAPER COVERING APPLIED
TO THE STOREFRONT GLAZING DURING FURNISHING.
6. PATCH & FIRESTOP GYP. BD. PARTITIONS AS REQUIRED
BY LOCAL CODES.
7. REFER TO BUILDING AND WALL SECTIONS FOR ALL
EXTERIOR WALL CONSTRUCTION.
8. REFER SHEET A-601 AND A-602 FOR PARTITION TYPES,
PARTITION TYPES SCHEDULE AND DETAILS.
9. REFER LS SHEET SERIES FOR FIRE PROTECTION/LIFE
SAFETY PLANS SHOWING LOCATION OF FIRE-RATED AND
SMOKE-RESISTANT PARTITIONS.
10. REFER TO I- SHEET SERIES AND IN100 SHEET SERIES
FOR FINISH SCHEDULE, FINISH PLANS, INTERIOR
ELEVATIONS, WALL PROTECTION SPECIALTIES (CORNER
GUARDS, CHAIR RAILS, ETC.).
11. REFER FF&E PACKAGE FOR FURNITURE, FIXTURES &
EQUIPMENT.
12. REFER A-600 SHEET SERIES FOR WINDOW AND CURTAIN
WALL FRAMES AND ELEVATIONS. INCLUDING WINDOWS
NOT VISIBLE ON THESE PLANS.
13. REFER TO A-200 SHEET SERIES DIMENSION PLANS FOR
ALL EXTERIOR, INTERIOR AND OPENING DIMENSIONS.
14. SEE SHEET A-606 FOR DOOR SCHEDULE.
15. ALL DOORS TO BE INSTALLED 4" CLEAR FROM ADJACENT
WALL ON HINGE SIDE, TYPICAL UNLESS NOTED
OTHERWISE OR DIMENSIONED.
16. ALL EXTERIOR DOORS SHALL SWING OUT WITH A
MINIMUM 110 DEGREE SWING FROM THE CLOSED
POSITION. ALL EXTERIOR DOORS SHALL HAVE WALL OR
FLOOR MOUNTED DOOR STOPS.
17. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0"
HIGH SHALL BE PROVIDED AND INSTALLED ON ALL
WALLS OF TELEPHONE AND ELECTRICAL ROOMS AS
REQUIRED UNLESS SPECIFICALLY SHOWN OTHERWISE
ON ELECTRICAL DRAWINGS.
18. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH THE CONTRACTING OFFICER PRIOR TO
INSTALLATION.
19. DISCONTINUE ALL DRYWALL ON INTERIOR FACE OF
EXTERIOR WALL AT ALL INTERSECTING WALLS, TYP.
20. WHERE FIRE RATED PARTITIONS INTERSECT WITH
LESSER RATED PARTITIONS OR NON-RATED
PARTITIONS, THE HIGHER RATED PARTITION IS TO
CONTINUE THROUGH THE INTERSECTION TO MAINTAIN
THE HIGHER RATING.
21. PROVIDE MASONRY EXPANSION JOINTS (EJ) WHERE
SHOWN ON PLANS AT BRICK VENEER, AND IN
ACCORDANCE WITH BRICK INDUSTRY ASSOCIATION
RECOMMENDATIONS.
22. PROVIDE MASONRY CONTROL JOINTS (CJ) WHERE
SHOWN ON PLANS AT CONCRETE MASONRY, IN
ACCORDANCE WITH STRUCTURAL DRAWINGS AND
REQUIREMENTS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
8'-0" 16'-0" 32'-0"
1/16" = 1'-0"
KEYPLAN
A-114
W A
L L C
O N
T R
O L J
O
IN
T P
L A
N
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/16" = 1'-0"A1
WALL CONTROL JOINT PLAN
D E
S
IG
N
/2
LE
D
LE
D
LE
D
LE
D
LE
D
LE
D
LE
DS
S
S
S
S
S
S
S
S
S
F F
F
S
M O S
F
J
A-201 F1
A-202 F1
A-201 C1
G1
A-301
G1
A-301
104A
104B
102A
SC1
110 111
002001
D1
A-303
A1
A-302
A1
A-301
A1
A-301
G1
A-302
G1
A-302
127D 127
E1
118A
125B
125C
104C
104D
100A 100
009 011
010007
015A 016
021B
021A
021C
021D
028027
T T
A A
B B
C
C
D D
E E
F F
G G
H H
J J
K K
L
M
M
N N
P P
R R
542 71.5
S
S
D1
A-301
D1
A-301
SB1
130SA1
125A
023022
G1
A-303
104E
A-201
A1
A-303 x-A-2151 x-A-215E1
101A
200 127A
D1
A-302
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
8'-0" 16'-0" 32'-0"
1/16" = 1'-0"
KEYPLAN
A-131
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
O V
E R
A L L
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/16" = 1'-0"A1
OVERALL CEILING PLAN
D E
S
IG
N
/2
LE
D
LE
D
S
F F
S
M O S
F
J
AT TORNADO SHELTER, 2-HR. RATED FURRING
ON STEEL BEAMS THAT SUPPORT CONCRETE
LID. ANY UL ASSEMBLY THAT INCLUDES FIRE
PROOFING ON DECK IS NOT PERMITTED.
E1
SB1
118A126
127D
127A
125B
125C
10'-0"
9'-0"
9'-0"
9'-0"
9'-0"
SC1
7'-7"
T
J
K
L
M
N
P
R
42 3.51.5 2.8
R.3
P.3
M.4
N.3
L.5
K.2
2.6
S
7'-4" FD
3/4" / 1'-0"
16'-0"
10'-0"
10'-9 1/2" FD
9'-5" FD
9'-5" FD
9'-0" FD
9'-0" FD
9'-2"
10'-0"
10'-0"
9 1/2"
1.6
10'-6"
12'-0"
10'-0"
'-0
3' -0
'-2
/2
7'
-0
7'-4" 10'-0"
9'-0"
125A 9'-0"
8'-0" FD
1'-3"
7" / 1'-0"
2'-2"
1'-3"
3' -1
8'
-1 0"
3' -1
A 1/
A -1
A 1/
A -1
A 1/
A -1
7" / 1'-0"
10'-6"
10'-6"
SA1
9'-0" FD 9'-0" FD
x-A-907
J1
H3
A-504
C1 x-A-907
H1
A-504
C5 x-A-907 __________________________________________ 8'-0"
10'-0" FD
9'-5" 15'-1 1/2"
2.3
9'-10" FD
7'-6" FD
5H
5S.1
7'-6" FD
10'-0"
1' -6
10'-0"
10'-0"
10'-0"
H1
A-503 x-A-215E1
2.9
R.5
9'-5"
9'-5" FD
M.1 9'-0" FD
9'-0" FD
10'-0" 10'-0"
C10 x-A-907
3.9
L.3
J.9
R.9 x-A-907
1'-0"
D1
A-302
AREA OPEN TO ABOVE
AS
AS
AS
AS
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
A-132
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/8" = 1'-0"A1
FIRST FLOOR RCP - AREA A
D E
S
IG
N
/2
LE
D
S
S
S
M O S
F
J
018 024
015A
021A
021B
021C
021D
T
J
K
L
M
N
P
R
J.3
K.1
L.4
P.2
N.1
P.9
S
9'-2" 9'-0"9'-0"
9'-9"
9'-9"
10'-10"
9'-9"
9'-9"
10'-9 1/2"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0" 10'-0"
9'-0"
10'-0"
10'-0"
10'-0"
8'-10"
10'-0"
10'-0"
10'-0"
7'-4"
1/2" / 1'-0"
8'-0"
7" / 1'-0"
1'-3"
3' -1
1"
A 1/
A -1
A 1/
A -1
A 1/
A -1
1'-3"
2'-2"
2'-2"
1'-3"
3' -2
8'
-1 0"
3' -1
7" / 1'-0"
7'-4"
AT TORNADO SHELTER, 2-HR. RATED FURRING ON
STEEL BEAMS THAT SUPPORT CONCRETE LID. ANY
UL ASSEMBLY THAT INCLUDES FIRE PROOFING ON
DECK IS NOT PERMITTED.
A-401
F6
10'-9"
16'-0"
6'-2"
A1
A-303
A-205 G1
A-205 D1
A-210 E1
R.5
M.1
5.8
5.8
L.3
J.9
R.9
AREA OPEN TO ABOVE
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
A-133
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
B
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/8" = 1'-0"A1
FIRST FLOOR RCP - AREA B
D E
S
IG
N
/2
S
S
F
F
AP
AP
AP
S
M O S
F
J
104B
102A
SC1
104A
100A
104C
104D
A
B
C
D
E
F
G
H
J
42 3.51.5 2.8
G.9
F.8
E.7
C.6
D.7
2.6 3
9'-2"9'-0"
10'-0"
10'-0"
1.6
9'-0"
A 1/
A -1
A 1/
A -1
A 1/
A -1
104E
F1
A-504
6'-2"
10'-0"
10'-0" A8
A-805
B10
A-503
15'-6"
7'-6"
RATED FURR DOWN AT BEAM
SUPPORTING STAIR (ABOVE)
8'-0"
9'-0"
101A
30'-0"
9'-6"12'-5"
1 2.9 3.9
D1
A-302
AREA OPEN TO ABOVE
AS
AS
AS
AS
AS
AS
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
A-134
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
C
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/8" = 1'-0"A1
FIRST FLOOR RCP - AREA C
D E
S
IG
N
/2
S
S
S
S
S
S
M O S
F
J
009 011
A
B
C
D
E
F
G
H
J
5 7
B.4
C.8
D.8
E.8
G.1
H.1
10'-0"
10'-0" 10'-0"
10'-0"
9'-0" 9'-2" 9'-0"
9'-0"
A 1/
A -1
A 1/
A -1
A 1/
A -1
16'-0"
6'-2"
A1
A-303
A-205 A1
A-210 E1
A-210 A1
5.8
AREA OPEN TO ABOVE
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
A-135
F
IR
S T
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
D
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/8" = 1'-0"A1
FIRST FLOOR RCP - AREA D
D E
S
IG
N
/2
S
D
S
M O S
F
J
A-201 F1
A-202 F1
A-201 C1
A-202 C1
G1
A-301
209B 209A
D1
A-303
A1
A-302
A1
A-301
218J
202B
202K
202J 202H202I
202A
M
G1
A-302
T T
A A
B B
C C
D D
E E
F F
G G
H H
J
J
K K
L L
M M
N N
P P
R R
542 71.5
R.3
P.3
M.4
N.3
G.9
F.8
E.7
S S
D1
A-301
SB2
ELEC
E2
W
218A
218B
218C
218D
218E
218F
218G
SA1
218H218I
SC2
202C
202D
202E
202F
S T
O R
G1
A-303
A-201
A1
A-303
A-211 A1
A-211 E1 x-A-2151 x-A-215E1
2.9
R.5 R.5
5.83.9
L.3 L.3
J.9 J.9
R.9 R.9
214A
214B
214C
D1
A-302
AREA OPEN TO ABOVE
AREA OPEN TO ABOVE AREA OPEN TO ABOVE
AREA OPEN TO ABOVE
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
8'-0" 16'-0" 32'-0"
1/16" = 1'-0"
KEYPLAN
A-136
S E
C O
N D
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
O V
E R
A L L
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/16" = 1'-0"A1
SECOND FLOOR RCP - OVERALL
D E
S
IG
N
/2
S
D
LED
S
M O S
F
J
209A209B
E2
218K
218J
218I
SA1
218H
218G
218F
218E
218D
218C
218B
218A
SB2
T
J
K
L
M
N
P
R
42 3.51.5 2.8
R.3
P.3
M.4
N.3
L.5
2.6
S
10'-6"
10'-0"
12'-5"
8'-0" 9'-0" 9'-0"
9'-0" FD11'-0"
11'-0"
9'-0" FD
9'-9" FD
1.6
10'-0"10'-0" 10'-0"
7'-9" FD 10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
9'-0"
9'-0"
10'-0"
9'-0"
10'-0"
10'-0" 10'-0"
10'-0"
1'-5 1/4"
7'-4" FD
10'-0"
46'-0"
1'-3"
8'-10" 3'-3" 2'-11"
9'-9" FD
12'-7"
12'-7"
7" / 1'-0"7'-4"
1' -3
2' -2
A 1/
A -1
4"
1' -0
[No Slope]
10'-0"
VENTED PREFINISHED METAL
SOFFIT PANEL. AREA PER CODE
REQ.
11'-0"
H1
A-504
H7
A-504
H3
A-504
H7
A-504
11'-0"
10'-0"
9'-9" FD
9'-0" FD
2.3
H7
A-504
7'-4"
8'-0"
36'-8"
53'-7"
53'-7"
44'-6 3/4"
26'-5 3/4"
20510'-0"
214C
214B
214A
10'-0"
10'-0"
10'-0"
8'-0" x-A-215E1
2.9
R.5
M.1 9'-0"
10'-0"
3.9
L.3
J.9
R.9
[No Slope]
D1
A-302
AREA OPEN TO ABOVE
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS AS
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
A-137
S E
C O
N D
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
A
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/8" = 1'-0"A1
SECOND FLOOR RCP - AREA A
D E
S
IG
N
/2
S
M O S
F
J
202I 202H202J
202K
202A
202G
202F
202E
202D
202C
202B
A
B
C
D
E
F
G
H
J
42 3.51.5 2.8
G.9
F.8
E.7
2.6 3
7'-4" FD
1.6
10'-0"
10'-0"
10'-0" 10'-0" 10'-0" 10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
SC2
1'-3"
A 1/
A -1
10'-0"
A-201
10'-0"
2.3
A8
A-805
10'-0"
10'-0"
10'-0"
A-207 E1
A-207 A1
A-212 A1
A-212 E1 x-A-2151
2.9 3.9
D1
A-302
AREA OPEN TO ABOVE
ACOUSTICAL CEILING TILE (ACT-1) 2'x2'
GYPSUM WALLBOARD (GWB-2)
CEILING
ACOUSTICAL CEILING TILE (ACT-2) 2'x2'
INTERIOR LIGHT FIXTURE
(RECESSED)
INTERIOR LIGHT FIXTURE
(SURFACE MTD)
REFLECTED CEILING PLAN LEGEND
INTERIOR LIGHT FIXTURE (RECESSED CAN)
INTERIOR LIGHT FIXTURE
(LINEAR PENDANT)
EXTERIOR LIGHT FIXTURE
AUDIO LOUDSPEAKER
OCCUPANCY SENSOR
SPOT ELEVATION - DENOTES CEILING HT.
A.F.F. WITHIN THE SAME SPACE, U.N.O.
EXIT SIGN (WALL MOUNT / CEILING MOUNT)
FIRE ALARM HORN/STROBE
EMERGENCY LIGHT FIXTURES
PROJECTION SCREEN
PROJECTOR
POWER/DATA JUNCTION BOX
HVAC DIFFUSER (SUPPLY / RETURN /
VENT EXHAUST)
ACCESS PANEL
CONTROL JOINT
EXPANSION JOINT
CJ
GYPSUM WALLBOARD (GWB-1)
CEILING, 1-HR RATED
EJ
REF. CEILING PLAN GENERAL NOTES
1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.
2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES
FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.
REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR
CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN
HERE.
3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.
4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,
ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL
ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK
ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF
ATTACHMENT TO STEEL.
6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT
SHOWN WITH CONTRACTING OFFICER PRIOR TO
INSTALLATION..
7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH
LIGHT GAUGE FRAMING TO PREVENT SWAYING.
8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE
CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.
9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT
LOCATIONS WHERE CEILING FRAMING MEMBERS
CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.
FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS
COORDINATE PROPOSED LOCATIONS WITH ARCHITECT
PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL
NOTES ON PARTITION TYPE SHEET A-601
10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE
FINISH SCHEDULE ON AF601 FOR PAINT COLORS.
11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR
SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE
CEILINGS WITHIN INTERSTITIAL SPACE.
• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE
RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.
1 HOUR, 2 HOUR, ETC.).
a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT
ALL OPENINGS"
• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF
EACH WALL AND AT INTERVALS NOT EXCEEDING 30
FT MEASURED HORIZONTALLY
• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN
HEIGHT WITH A MINIMUM 3/8” STROKE IN A
CONTRASTING COLOR OF THE WALL COLOR
12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL
GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN
LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP
DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE
COORDINATED WITH AOR PRIOR TO INSTALLATION.
13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM
BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
X
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
M A
R K
D E
S C
R
IP
T
IO
N
D A
T E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
3817 NW EXPRESSWAY
SUITE 840
OKLAHOMA CITY, OK 73112
(405) 722-7270
Larson Design Group
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
A-138
S E
C O
N D
F L O
O R
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A R
E A
C
T
IN
K E
R A
IR
F
O R
C E
B A
S E
O
K
T U
L S
A D
IS
T
R
IC
T E
S
T S
T R
E E
T T
U L S
A O
K
-4
E N
G
IN
E E
R
IN
G
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
E N
G
IN
E E
R
IN
G B
R A
N C
H
R S
IL
E
R
R U
L M
S N
A L L
A M
A L A
N O
W S
K I
N O
V E
M B
E R
W B
V -1
-D
-0
W B
V -2
-D
-0
D E
S
IG
N
B O
M B
E R
A G
IL
E
C O
M M
O N
H A
N G
A R
W W
Y K
1/8" = 1'-0"A1
SECOND FLOOR RCP - AREA C
D E
S
IG
N
/2
| V1_80 ARCHITECTURAL |
| Sheets |
| A-113 - AIR BARRIER BUILDING SECTIONS |
| A-114 - WALL CONTROL JOINT PLAN |
| A-131 - FIRST FLOOR REFLECTED CEILING PLAN - OVERALL |
| A-132 - FIRST FLOOR REFLECTED CEILING PLAN - AREA A |
| A-133 - FIRST FLOOR REFLECTED CEILING PLAN - AREA B |
| A-134 - FIRST FLOOR REFLECTED CEILING PLAN - AREA C |
| A-135 - FIRST FLOOR REFLECTED CEILING PLAN - AREA D |
| A-136 - SECOND FLOOR REFLECTED CEILING PLAN - OVERALL |
| A-137 - SECOND FLOOR REFLECTED CEILING PLAN - AREA A |
| A-138 - SECOND FLOOR REFLECTED CEILING PLAN - AREA C |
File details come from the government source that posted it. Updated .