WWYK263009_65 Drawings_Volume 1_Part6_Part2.pdf

PDF 6 MB Posted

Attached to
Bomber Agile Common Hangar; 4-Dock Hangar at Tinker Air Force Base
Solicitation number
W912BV25S0014
Issued by

About this file

These are architectural drawings depicting reflected ceiling plans and air barrier building sections for a Bomber Agile Common Hangar project at Tinker Air Force Base. The drawings show detailed plans for a large hangar facility with administrative, shop, and hangar bay areas, including specifications for air barrier systems, ceiling types, lighting fixtures, and control joints.

The drawings indicate the hangar has significant square footage requirements, with the administrative area having 6,670 SF of walls, 2,151 SF of glazing, and 24,058 SF of roofing, while the hangar bay has 101,616 SF of walls, 25,560 SF of glazing, and 148,916 SF of roofing. The facility includes multiple ceiling types including acoustical ceiling tiles and gypsum wallboard, with ceiling heights generally at 10'-0" above finished floor. The drawings contain extensive technical details about lighting placement, HVAC diffusers, access panels, and other ceiling-mounted equipment. Air barrier details show careful attention to sealing penetrations and material transitions within air barrier boundaries to ensure proper building envelope performance.

View the file

Other files

File Type Posted
WWYK263009_65 Design Analysis_Part12_Part2.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part6_Part1.pdf PDF
WWYK263009_65 Design Analysis_Part18_Part6.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part1.pdf PDF
WWYK263009_65 Design Analysis Part 28_Part3.pdf PDF
WWYK263009_65 Drawings_Volume 2_Part5.pdf PDF
WWYK263009_65_NG-LCCA_BLCC_Summary Report.pdf PDF
WWYK263009_65 Design Analysis_Part24.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part4_Part7.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part4.pdf PDF
WWYK263009_65 Design Analysis_Part22_Part4_Part3.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part4_Part1.pdf PDF
WWYK263009_65 Design Analysis_Part17.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part19_Part3.pdf PDF
WWYK263009_65 Design Analysis_Part10.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part8.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part1.pdf PDF
WWYK263009_65_NG_energy model results.pdf PDF
Bomber Agile Common Hangar Industry Forum Presentation.pdf PDF
WWYK263009_65 Drawings_Volume 2_Part6.pdf PDF
WWYK263009_65 Design Analysis_Part22_Part4_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part18_Part2.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part4_Part4.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part7.pdf PDF
WWYK263009_65 Design Analysis_Part21.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part6_Part4_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part23.pdf PDF
WWYK263009_65 Design Analysis_Part22_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part4.pdf PDF
WWYK263009_65 Design Analysis_Part19_Part2.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part3.pdf PDF
WWYK263009_65 Design Analysis_Part20.pdf PDF
WWYK263009_65 Design Analysis Part 28_Part2.pdf PDF
WWYK263009_65 Design Analysis_Part26.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part5.pdf PDF
WWYK263009_65 Design Analysis_Part19_Part4.pdf PDF
WWYK263009_65 Design Analysis_Part27.pdf PDF
WWYK263009_65 Design Analysis_Part18_Part5.pdf PDF
WWYK263009_65 Design Analysis_Part15.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part3.pdf PDF
WWYK263009_65 Design Analysis Part 28_Part4.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part9.pdf PDF
WWYK263009_65 Design Analysis_Part9.pdf PDF
WWYK263009_65 Design Analysis_Part12_Part4.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part7_Part1.pdf PDF
WWYK263009_65 Drawings_Volume 1_Part1_Part5.pdf PDF
WWYK263009_65_NG-LCCA_BLCC results.pdf PDF
WWYK263009_65 Design Analysis_Part7.pdf PDF
Show 40 more

Latest 50 of 95 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEGEND:

AIR BARRIER INSPECTION

AND TESTING

AIR BARRIER INSPECTION

ONLY

AREAS OUTSIDE OF THE AIR

BARRIER

AIR BARRIER LOCATION AT

MEMBRANES/FLASHING

OTHER BUILDING

ELEMENTS ACTING AS AIR

BARRIER

OTHER BUILDING

ELEMENTS

ADMINISTRATIVE HANGAR BAY SHOPS

WALLS 6,670 SF 101,616 SF 15,658 SF

GLAZING 2,151 SF 25,560 SF 120 SF

DOORS 1,412 SF 34,705 SF 2,246 SF

ROOFING 24,058 SF 148,916 SF 16,375 SF

NOTE: BTM PORTION OF HANGAR WALLS CALCULATED

WITHIN ADMINISTRATIVE OR SHOP TESTING AREAS

RESPECTIVELY.

SIX-SIDED AREA OF THE AIR BARRIER ENVELOPE:

GENERAL NOTES (AIR BARRIER):

1. SEAL ALL AIR BARRIER PENETRATIONS WITH AIR

BARRIER FLASHING & CAULK.

2. REFER TO DETAIL SHEETS FOR MATERIAL

TRANSITIONS WITHIN AIR BARRIER BOUNDARIES.

FIRST FLOOR

100'-0"

HANGAR DOOR

99'-2"

SECOND FLOOR

118'-1"

ADMIN. ROOF

135'-0"

HANGAR ROOF RIDGE

210'-2"

HANGAR DOOR HEAD

161'-5"

F1

A-113

HANGAR ROOF

190'-2"

1.5 3

G1

A-303

2.3

A1

A-303

1 2.9

5.8

3.9

D1

A-302

FIRST FLOOR

100'-0"

HANGAR DOOR

99'-2"

SECOND FLOOR

118'-1"

ADMIN. ROOF

135'-0"

HANGAR ROOF RIDGE

210'-2"

A1

A-113

HANGAR DOOR HEAD

161'-5"

HANGAR ROOF

190'-2"

T ABCDEFGHJKLMNRR.3 P.2S R.5 M.1 L.3 J.9R.9

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

8'-0" 16'-0" 32'-0"

1/16" = 1'-0"

A-113

A

IR

B A

R R

IE

R

B U

IL

D

IN

G

S E

C T

IO

N

S

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

K B

L A

N D

F O

R D

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/16" = 1'-0"A1

BUILDING SECTION - AIR BARRIER

1/16" = 1'-0"F1

BUILDING SECTION - AIR BARRIER

D E

S

IG

N

/2

/2

T

A

B

C

D

E

F

G

H

K

L

M

N

P

R

542 71.5 2.8

R.3

P.3

M.4

N.3

L.5

K.2

G.9

F.8

E.7

C.6

D.7

S

32.31 2.9

R.5

M.1

5.83.9

J.9

R.9

PSC

HAZ STOR

HAZ WSTE

102A

TOOL CRIB

STAIR

SC1

KITTING

104B

AIR

ELEC

MECH

COMPOSITE

104A

FOM STORAGE

DOCK OFFICE

LANDING GEAR SHOP

ENGINE SHOP

DOCK OFFICE

TIRE (OPEN) SHOP

SHEET METAL

DLA/IPV

COMPOSITE

HANGAR BAY

EXIT PASSAGEWAY

CORRIDOR

CORRIDOR

VEST.

CORRIDOR

VEST.

VEST.

BRK RM/TORNADO

SHELTER

FIRE

COMM

BRK RM/TORNADO

SHELTER

WELL

DOCK OFFICE

PMD

LO STOR

ELEV

E1

STAIR

SB1

T O

O L

C H

E C

K O

U T

CORRIDOR

100A

VEST.

SERVER

127D

VEST.

CORRIDOR

118A

M

W

WOMENS

MENS

VEST.

JAN

AIR

015A

ELEC

COMM

MECH

DOCK OFFICE

FIRE

CORRIDOR

TC OFFICE

104C

VEST.

MENS

WOMENS

M

021C

W

021B

WELL

021A

MENS

WOMENS

TC OPEN OFF.

104D

STAIR

SA1

CORRIDOR

VEST.

CLOSET

AMT

104E

1'

-0

/8

F10

C10

FOM OFF.

101A

HANGAR DOCK #3

HANGAR DOCK #4

HANGAR DOCK #2

HANGAR DOCK #1

3' -4

'-0

0'

-8

2' -0

'-0

'-0

'-8

'-0

9'

-8

1/ 4"

JAN

JAN

CLOSET

(NDI)

021D

VEST

127A

3'

-1

3/ 4"

5' -4

'-0

7' -8

8'

-0

8' -0

8'

-0

'-0

8'

-0

9' -8

'-0

5' -4

'-0

'-0

'-0

9' -0

'-0

4' -4

MACH RM

7'

-9

6'

-2

/2

50'-0"

'-0

'-0

7' -0

8'

-0

'-0

7'

-0

7' -0

'-0

7' -0

7'

-0

'-0

7'

-0

7' -0

'-0

8' -0

9'

-0

8' -0

8'

-0

'-0

'-0

'-0

'-0

8' -0

8'

-0

'-0

'-0

8' -0

8'

-0

'-0

8'

-0

8' -0

8'

-0

8' -0

'-0

'-0

'-0

'-0

6'

-0

7' -4

'-4

4' -0

2'-0" 9'-0" 9'-0" 10'-0" 9'-0" 9'-0" 2'-0"

2'-0" 9'-0" 9'-0" 10'-0" 9'-0" 9'-0" 2'-0"

2'-0" 9'-0" 9'-0" 10'-0" 9'-0" 9'-0" 2'-0"

CJ

CJ

CJ

CJ

2'-0"

FLOOR PLAN GENERAL NOTES

1. VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION.

2. DIMENSIONS SHOWN ARE LOCATED TO EDGE OF SLAB,

EDGE OF CURB, CENTER LINE OF COLUMNS, FACE OF

STUD, UNO.

3. DIMENSIONS MARKED AS "CLR" DICTATES THE CLEAR

DIMENSION FROM FINISH TO FINISH

4. APPROVED FIRE EXTINGUISHERS MUST BE FURNISHED

AND INSTALLED BY G.C. AS REQUIRED BY LOCAL

AUTHORITY.

5. PROVIDE & INSTALL BROWN PAPER COVERING APPLIED

TO THE STOREFRONT GLAZING DURING FURNISHING.

6. PATCH & FIRESTOP GYP. BD. PARTITIONS AS REQUIRED

BY LOCAL CODES.

7. REFER TO BUILDING AND WALL SECTIONS FOR ALL

EXTERIOR WALL CONSTRUCTION.

8. REFER SHEET A-601 AND A-602 FOR PARTITION TYPES,

PARTITION TYPES SCHEDULE AND DETAILS.

9. REFER LS SHEET SERIES FOR FIRE PROTECTION/LIFE

SAFETY PLANS SHOWING LOCATION OF FIRE-RATED AND

SMOKE-RESISTANT PARTITIONS.

10. REFER TO I- SHEET SERIES AND IN100 SHEET SERIES

FOR FINISH SCHEDULE, FINISH PLANS, INTERIOR

ELEVATIONS, WALL PROTECTION SPECIALTIES (CORNER

GUARDS, CHAIR RAILS, ETC.).

11. REFER FF&E PACKAGE FOR FURNITURE, FIXTURES &

EQUIPMENT.

12. REFER A-600 SHEET SERIES FOR WINDOW AND CURTAIN

WALL FRAMES AND ELEVATIONS. INCLUDING WINDOWS

NOT VISIBLE ON THESE PLANS.

13. REFER TO A-200 SHEET SERIES DIMENSION PLANS FOR

ALL EXTERIOR, INTERIOR AND OPENING DIMENSIONS.

14. SEE SHEET A-606 FOR DOOR SCHEDULE.

15. ALL DOORS TO BE INSTALLED 4" CLEAR FROM ADJACENT

WALL ON HINGE SIDE, TYPICAL UNLESS NOTED

OTHERWISE OR DIMENSIONED.

16. ALL EXTERIOR DOORS SHALL SWING OUT WITH A

MINIMUM 110 DEGREE SWING FROM THE CLOSED

POSITION. ALL EXTERIOR DOORS SHALL HAVE WALL OR

FLOOR MOUNTED DOOR STOPS.

17. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0"

HIGH SHALL BE PROVIDED AND INSTALLED ON ALL

WALLS OF TELEPHONE AND ELECTRICAL ROOMS AS

REQUIRED UNLESS SPECIFICALLY SHOWN OTHERWISE

ON ELECTRICAL DRAWINGS.

18. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH THE CONTRACTING OFFICER PRIOR TO

INSTALLATION.

19. DISCONTINUE ALL DRYWALL ON INTERIOR FACE OF

EXTERIOR WALL AT ALL INTERSECTING WALLS, TYP.

20. WHERE FIRE RATED PARTITIONS INTERSECT WITH

LESSER RATED PARTITIONS OR NON-RATED

PARTITIONS, THE HIGHER RATED PARTITION IS TO

CONTINUE THROUGH THE INTERSECTION TO MAINTAIN

THE HIGHER RATING.

21. PROVIDE MASONRY EXPANSION JOINTS (EJ) WHERE

SHOWN ON PLANS AT BRICK VENEER, AND IN

ACCORDANCE WITH BRICK INDUSTRY ASSOCIATION

RECOMMENDATIONS.

22. PROVIDE MASONRY CONTROL JOINTS (CJ) WHERE

SHOWN ON PLANS AT CONCRETE MASONRY, IN

ACCORDANCE WITH STRUCTURAL DRAWINGS AND

REQUIREMENTS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

8'-0" 16'-0" 32'-0"

1/16" = 1'-0"

KEYPLAN

A-114

W A

L L C

O N

T R

O L J

O

IN

T P

L A

N

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/16" = 1'-0"A1

WALL CONTROL JOINT PLAN

D E

S

IG

N

/2

LE

D

LE

D

LE

D

LE

D

LE

D

LE

D

LE

DS

S

S

S

S

S

S

S

S

S

F F

F

S

M O S

F

J

A-201 F1

A-202 F1

A-201 C1

G1

A-301

G1

A-301

104A

104B

102A

SC1

110 111

002001

D1

A-303

A1

A-302

A1

A-301

A1

A-301

G1

A-302

G1

A-302

127D 127

E1

118A

125B

125C

104C

104D

100A 100

009 011

010007

015A 016

021B

021A

021C

021D

028027

T T

A A

B B

C

C

D D

E E

F F

G G

H H

J J

K K

L

M

M

N N

P P

R R

542 71.5

S

S

D1

A-301

D1

A-301

SB1

130SA1

125A

023022

G1

A-303

104E

A-201

A1

A-303 x-A-2151 x-A-215E1

101A

200 127A

D1

A-302

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

8'-0" 16'-0" 32'-0"

1/16" = 1'-0"

KEYPLAN

A-131

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

O V

E R

A L L

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/16" = 1'-0"A1

OVERALL CEILING PLAN

D E

S

IG

N

/2

LE

D

LE

D

S

F F

S

M O S

F

J

AT TORNADO SHELTER, 2-HR. RATED FURRING

ON STEEL BEAMS THAT SUPPORT CONCRETE

LID. ANY UL ASSEMBLY THAT INCLUDES FIRE

PROOFING ON DECK IS NOT PERMITTED.

E1

SB1

118A126

127D

127A

125B

125C

10'-0"

9'-0"

9'-0"

9'-0"

9'-0"

SC1

7'-7"

T

J

K

L

M

N

P

R

42 3.51.5 2.8

R.3

P.3

M.4

N.3

L.5

K.2

2.6

S

7'-4" FD

3/4" / 1'-0"

16'-0"

10'-0"

10'-9 1/2" FD

9'-5" FD

9'-5" FD

9'-0" FD

9'-0" FD

9'-2"

10'-0"

10'-0"

9 1/2"

1.6

10'-6"

12'-0"

10'-0"

'-0

3' -0

'-2

/2

7'

-0

7'-4" 10'-0"

9'-0"

125A 9'-0"

8'-0" FD

1'-3"

7" / 1'-0"

2'-2"

1'-3"

3' -1

8'

-1 0"

3' -1

A 1/

A -1

A 1/

A -1

A 1/

A -1

7" / 1'-0"

10'-6"

10'-6"

SA1

9'-0" FD 9'-0" FD

x-A-907

J1

H3

A-504

C1 x-A-907

H1

A-504

C5 x-A-907 __________________________________________ 8'-0"

10'-0" FD

9'-5" 15'-1 1/2"

2.3

9'-10" FD

7'-6" FD

5H

5S.1

7'-6" FD

10'-0"

1' -6

10'-0"

10'-0"

10'-0"

H1

A-503 x-A-215E1

2.9

R.5

9'-5"

9'-5" FD

M.1 9'-0" FD

9'-0" FD

10'-0" 10'-0"

C10 x-A-907

3.9

L.3

J.9

R.9 x-A-907

1'-0"

D1

A-302

AREA OPEN TO ABOVE

AS

AS

AS

AS

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

A-132

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

A

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR RCP - AREA A

D E

S

IG

N

/2

LE

D

S

S

S

M O S

F

J

018 024

015A

021A

021B

021C

021D

T

J

K

L

M

N

P

R

J.3

K.1

L.4

P.2

N.1

P.9

S

9'-2" 9'-0"9'-0"

9'-9"

9'-9"

10'-10"

9'-9"

9'-9"

10'-9 1/2"

10'-0"

10'-0"

10'-0"

10'-0"

10'-0" 10'-0"

9'-0"

10'-0"

10'-0"

10'-0"

8'-10"

10'-0"

10'-0"

10'-0"

7'-4"

1/2" / 1'-0"

8'-0"

7" / 1'-0"

1'-3"

3' -1

1"

A 1/

A -1

A 1/

A -1

A 1/

A -1

1'-3"

2'-2"

2'-2"

1'-3"

3' -2

8'

-1 0"

3' -1

7" / 1'-0"

7'-4"

AT TORNADO SHELTER, 2-HR. RATED FURRING ON

STEEL BEAMS THAT SUPPORT CONCRETE LID. ANY

UL ASSEMBLY THAT INCLUDES FIRE PROOFING ON

DECK IS NOT PERMITTED.

A-401

F6

10'-9"

16'-0"

6'-2"

A1

A-303

A-205 G1

A-205 D1

A-210 E1

R.5

M.1

5.8

5.8

L.3

J.9

R.9

AREA OPEN TO ABOVE

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

A-133

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

B

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR RCP - AREA B

D E

S

IG

N

/2

S

S

F

F

AP

AP

AP

S

M O S

F

J

104B

102A

SC1

104A

100A

104C

104D

A

B

C

D

E

F

G

H

J

42 3.51.5 2.8

G.9

F.8

E.7

C.6

D.7

2.6 3

9'-2"9'-0"

10'-0"

10'-0"

1.6

9'-0"

A 1/

A -1

A 1/

A -1

A 1/

A -1

104E

F1

A-504

6'-2"

10'-0"

10'-0" A8

A-805

B10

A-503

15'-6"

7'-6"

RATED FURR DOWN AT BEAM

SUPPORTING STAIR (ABOVE)

8'-0"

9'-0"

101A

30'-0"

9'-6"12'-5"

1 2.9 3.9

D1

A-302

AREA OPEN TO ABOVE

AS

AS

AS

AS

AS

AS

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

A-134

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

C

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR RCP - AREA C

D E

S

IG

N

/2

S

S

S

S

S

S

M O S

F

J

009 011

A

B

C

D

E

F

G

H

J

5 7

B.4

C.8

D.8

E.8

G.1

H.1

10'-0"

10'-0" 10'-0"

10'-0"

9'-0" 9'-2" 9'-0"

9'-0"

A 1/

A -1

A 1/

A -1

A 1/

A -1

16'-0"

6'-2"

A1

A-303

A-205 A1

A-210 E1

A-210 A1

5.8

AREA OPEN TO ABOVE

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

A-135

F

IR

S T

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

D

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

FIRST FLOOR RCP - AREA D

D E

S

IG

N

/2

S

D

S

M O S

F

J

A-201 F1

A-202 F1

A-201 C1

A-202 C1

G1

A-301

209B 209A

D1

A-303

A1

A-302

A1

A-301

218J

202B

202K

202J 202H202I

202A

M

G1

A-302

T T

A A

B B

C C

D D

E E

F F

G G

H H

J

J

K K

L L

M M

N N

P P

R R

542 71.5

R.3

P.3

M.4

N.3

G.9

F.8

E.7

S S

D1

A-301

SB2

ELEC

E2

W

218A

218B

218C

218D

218E

218F

218G

SA1

218H218I

SC2

202C

202D

202E

202F

S T

O R

G1

A-303

A-201

A1

A-303

A-211 A1

A-211 E1 x-A-2151 x-A-215E1

2.9

R.5 R.5

5.83.9

L.3 L.3

J.9 J.9

R.9 R.9

214A

214B

214C

D1

A-302

AREA OPEN TO ABOVE

AREA OPEN TO ABOVE AREA OPEN TO ABOVE

AREA OPEN TO ABOVE

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

8'-0" 16'-0" 32'-0"

1/16" = 1'-0"

KEYPLAN

A-136

S E

C O

N D

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

O V

E R

A L L

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/16" = 1'-0"A1

SECOND FLOOR RCP - OVERALL

D E

S

IG

N

/2

S

D

LED

S

M O S

F

J

209A209B

E2

218K

218J

218I

SA1

218H

218G

218F

218E

218D

218C

218B

218A

SB2

T

J

K

L

M

N

P

R

42 3.51.5 2.8

R.3

P.3

M.4

N.3

L.5

2.6

S

10'-6"

10'-0"

12'-5"

8'-0" 9'-0" 9'-0"

9'-0" FD11'-0"

11'-0"

9'-0" FD

9'-9" FD

1.6

10'-0"10'-0" 10'-0"

7'-9" FD 10'-0"

10'-0"

10'-0"

10'-0"

10'-0"

10'-0"

10'-0"

9'-0"

9'-0"

10'-0"

9'-0"

10'-0"

10'-0" 10'-0"

10'-0"

1'-5 1/4"

7'-4" FD

10'-0"

46'-0"

1'-3"

8'-10" 3'-3" 2'-11"

9'-9" FD

12'-7"

12'-7"

7" / 1'-0"7'-4"

1' -3

2' -2

A 1/

A -1

4"

1' -0

[No Slope]

10'-0"

VENTED PREFINISHED METAL

SOFFIT PANEL. AREA PER CODE

REQ.

11'-0"

H1

A-504

H7

A-504

H3

A-504

H7

A-504

11'-0"

10'-0"

9'-9" FD

9'-0" FD

2.3

H7

A-504

7'-4"

8'-0"

36'-8"

53'-7"

53'-7"

44'-6 3/4"

26'-5 3/4"

20510'-0"

214C

214B

214A

10'-0"

10'-0"

10'-0"

8'-0" x-A-215E1

2.9

R.5

M.1 9'-0"

10'-0"

3.9

L.3

J.9

R.9

[No Slope]

D1

A-302

AREA OPEN TO ABOVE

AS

AS

AS

AS

AS

AS

AS

AS

AS

AS

AS

AS

AS

AS

AS

AS AS

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

A-137

S E

C O

N D

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

A

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

SECOND FLOOR RCP - AREA A

D E

S

IG

N

/2

S

M O S

F

J

202I 202H202J

202K

202A

202G

202F

202E

202D

202C

202B

A

B

C

D

E

F

G

H

J

42 3.51.5 2.8

G.9

F.8

E.7

2.6 3

7'-4" FD

1.6

10'-0"

10'-0"

10'-0" 10'-0" 10'-0" 10'-0"

10'-0"

10'-0"

10'-0"

10'-0"

SC2

1'-3"

A 1/

A -1

10'-0"

A-201

10'-0"

2.3

A8

A-805

10'-0"

10'-0"

10'-0"

A-207 E1

A-207 A1

A-212 A1

A-212 E1 x-A-2151

2.9 3.9

D1

A-302

AREA OPEN TO ABOVE

ACOUSTICAL CEILING TILE (ACT-1) 2'x2'

GYPSUM WALLBOARD (GWB-2)

CEILING

ACOUSTICAL CEILING TILE (ACT-2) 2'x2'

INTERIOR LIGHT FIXTURE

(RECESSED)

INTERIOR LIGHT FIXTURE

(SURFACE MTD)

REFLECTED CEILING PLAN LEGEND

INTERIOR LIGHT FIXTURE (RECESSED CAN)

INTERIOR LIGHT FIXTURE

(LINEAR PENDANT)

EXTERIOR LIGHT FIXTURE

AUDIO LOUDSPEAKER

OCCUPANCY SENSOR

SPOT ELEVATION - DENOTES CEILING HT.

A.F.F. WITHIN THE SAME SPACE, U.N.O.

EXIT SIGN (WALL MOUNT / CEILING MOUNT)

FIRE ALARM HORN/STROBE

EMERGENCY LIGHT FIXTURES

PROJECTION SCREEN

PROJECTOR

POWER/DATA JUNCTION BOX

HVAC DIFFUSER (SUPPLY / RETURN /

VENT EXHAUST)

ACCESS PANEL

CONTROL JOINT

EXPANSION JOINT

CJ

GYPSUM WALLBOARD (GWB-1)

CEILING, 1-HR RATED

EJ

REF. CEILING PLAN GENERAL NOTES

1. ALL CEILINGS TO BE LOCATED AT 10'-0" A.F.F. U. N. O.

2. THESE DRAWINGS INDICATE THE LIMITS OF FINISHES

FOR AREAS THAT HAVE MULTIPLE TYPES AND COLORS.

REFER TO THE FINISH SCHEDULE IN THE AF SERIES FOR

CEILING MATERIAL & COLOR DESIGNATIONS NOT SHOWN

HERE.

3. ALL FURRDOWNS SHALL BE PAINTED PT-1 U.N.O.

4. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

5. ALL CEILINGS, FURRDOWNS, PIPES, DUCTS, EQUIPMENT,

ETC. SHALL BE SUSPENDED FROM STRUCTURAL STEEL

ABOVE. DO NOT SUPPORT ITEMS FROM METAL DECK

ONLY. REFER TO STRUCTURAL FOR REQUIREMENTS OF

ATTACHMENT TO STEEL.

6. COORDINATE LOCATION OF ANY CONTROL JOINTS NOT

SHOWN WITH CONTRACTING OFFICER PRIOR TO

INSTALLATION..

7. ALL CEILING FURRDOWNS SHALL BE BRACED WITH

LIGHT GAUGE FRAMING TO PREVENT SWAYING.

8. UNLESS DIMENSIONED ON PLANS, LIGHTS TO BE

CENTERED AND DISTRIBUTED EVENLY IN ROOM/AREA.

9. PROVIDE DRYWALL CONTROL JOINTS AT 30' MAX O.C., AT

LOCATIONS WHERE CEILING FRAMING MEMBERS

CHANGE DIRECTION, OR WHERE SHOWN ON DRAWINGS.

FOR CONTROLS JOINTS NOT SHOW ON DRAWINGS

COORDINATE PROPOSED LOCATIONS WITH ARCHITECT

PRIOR TO INSTALLATION. SEE ADDITIONAL DRYWALL

NOTES ON PARTITION TYPE SHEET A-601

10. ALL EXPOSED STRUCTURE SHALL BE PAINTED. SEE

FINISH SCHEDULE ON AF601 FOR PAINT COLORS.

11. PER NFPA 101 SECTION 8.2.2.5: ON ALL RATED OR

SMOKE BARRIERS, PROVIDE THE FOLLOWING ABOVE

CEILINGS WITHIN INTERSTITIAL SPACE.

• TEXT THAT IDENTIFIES THE WALL TYPE (I.E. FIRE

RATED AND OR SMOKE RATED) AND FIRE RATING (I.E.

1 HOUR, 2 HOUR, ETC.).

a. EXAMPLE TEXT: "1 HOUR FIRE RATED - PROTECT

ALL OPENINGS"

• TEXT TO BE LOCATED WITHIN 15 FT OF THE END OF

EACH WALL AND AT INTERVALS NOT EXCEEDING 30

FT MEASURED HORIZONTALLY

• LETTERING SHALL NOT BE LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8” STROKE IN A

CONTRASTING COLOR OF THE WALL COLOR

12. PROVIDE PAINT GRADE CEILING ACCESS PANEL AT ALL

GYP. BOARD CEILINGS AT VAV, FC AND EXHAUST FAN

LOCATIONS WHETHER OR NOT IT IS SHOWN ON RCP

DRAWINGS. NON SHOWN PANEL LOCATIONS TO BE

COORDINATED WITH AOR PRIOR TO INSTALLATION.

13. PROVIDE MOISTURE / MILDEW RESISTANT GYPSUM

BOARD AT JANITOR CLOSET AND RESTROOMS CEILINGS.

C

A B

D

AN

R P

M

E L

I

I R Y

N G

E S

I

D

NOT FOR

CONSTRUCTION

N

PLAN

NORTH

SCALE:

US Army Corps of Engineers

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

X

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

M A

R K

D E

S C

R

IP

T

IO

N

D A

T E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

H

J

2 3 4 5 6 7 8 9 10 11 12

3817 NW EXPRESSWAY

SUITE 840

OKLAHOMA CITY, OK 73112

(405) 722-7270

Larson Design Group

4'-0" 8'-0" 16'-0"

1/8" = 1'-0"

KEYPLAN

A-138

S E

C O

N D

F L O

O R

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

C

T

IN

K E

R A

IR

F

O R

C E

B A

S E

O

K

T U

L S

A D

IS

T

R

IC

T E

S

T S

T R

E E

T T

U L S

A O

K

-4

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

R S

IL

E

R

R U

L M

S N

A L L

A M

A L A

N O

W S

K I

N O

V E

M B

E R

W B

V -1

-D

-0

W B

V -2

-D

-0

D E

S

IG

N

B O

M B

E R

A G

IL

E

C O

M M

O N

H A

N G

A R

W W

Y K

1/8" = 1'-0"A1

SECOND FLOOR RCP - AREA C

D E

S

IG

N

/2

V1_80 ARCHITECTURAL
Sheets
A-113 - AIR BARRIER BUILDING SECTIONS
A-114 - WALL CONTROL JOINT PLAN
A-131 - FIRST FLOOR REFLECTED CEILING PLAN - OVERALL
A-132 - FIRST FLOOR REFLECTED CEILING PLAN - AREA A
A-133 - FIRST FLOOR REFLECTED CEILING PLAN - AREA B
A-134 - FIRST FLOOR REFLECTED CEILING PLAN - AREA C
A-135 - FIRST FLOOR REFLECTED CEILING PLAN - AREA D
A-136 - SECOND FLOOR REFLECTED CEILING PLAN - OVERALL
A-137 - SECOND FLOOR REFLECTED CEILING PLAN - AREA A
A-138 - SECOND FLOOR REFLECTED CEILING PLAN - AREA C

File details come from the government source that posted it. Updated .