TINKER AIR FORCE BASE, OKLAHOMA
WWYK263009
BOMBER AGILE COMMON HANGAR
65% Furniture, Fixture, & Equipment (FF&E) Binder November 20, 2024
PREPARED FOR:
US ARMY CORPS OF ENGINEERS
TULSA DISTRICT
TABLE OF CONTENTS
COST ESTIMATE
COLOR BOARDS AND MATERIAL SAMPLES
REFLECTED CEILING PLANS
ITEM CODE LIST
FURNITURE SPECIFICATIONS
FURNITURE, FIXTURE, AND EQUIPMENT PLANS
DESIGN NARRATIVE
POINT OF CONTACT
POWER AND TELECOM PLANS
TAB 1
TAB 2
TAB 3
TAB 4
TAB 5
TAB 6
TAB 7
TAB 8
TAB 9
Bomber Agile Common Hangar (BACH) Project No.: WWYK263009 Tinker Air Force Base, Oklahoma
DA Segment 5 Interior Design - 1
SECTION 5 - INTERIOR DESIGN
5.1 GENERAL PARAMETERS
The interior design is integrated as part of the building’s complete design, expressing the User’s functional and aesthetic needs. Quality materials and furnishings, appropriate to the design, are used to provide a supportive environment for the Agile Hangar in Tinker Air Force Base.
As part of the construction project, a Comprehensive Interior Design (CID) package has been incorporated into the complete design, which is formatted under the Interior Design Unified Facilities Criteria, UFC 3-120-10. The CID consists of two parts: Furniture, Fixtures & Equipment (FF&E) and Structural Interior Design (SID).
For this project, the blue gray colorway has been selected to create a transitional interior that will provide a pleasing aesthetic for years to come.
Finish selections made for the facility as well as for the furnishings work together to create a cohesive design.
5.2 DESIGN CRITERIA
Refer to separate Section GENERAL, Subsection "General Design Guidance and Criteria" located at the beginning of this Design Analysis narrative.
INTERIOR DESIGN
UFC 3-120-01 Design: Sign Standards Change 3 UFC 3-120-10 Interior Design UFC 1-200-02 Architecture/Interior Design Guiding Principles Requirements ANSI/BIFMA Safety and Performance Standards for Furniture ABA Architectural Barriers Act Standards ASTM D 2047 Test for Slip Resistance of Hard Surfaces ETL 07-4 Air Force Carpet Standard NFPA 260 Methods of Tests and Classification System for Cigarette
Ignition Resistance of Components NFPA 261 Method of Test for Determining Resistance of Mock-Up
Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes
UFC 1-200-01 General Building Requirements with Change 1 Wyzenbeek Wyzenbeek Abrasion Resistance Test AFCH Air Force Reserve Command Handbook AFMAN Air Force Manual Design Guide Tinker Air Force Base Design Guide
DA Segment 5 Interior Design - 2
5.3 INTERIOR DESIGN
5.3.1 Furniture
The furniture layout has been developed to make the most efficient use of floor space based on input gathered at the Charrette and following Review meetings. The FF&E items shown on I-series drawings include seating, desks, tables, storage, and miscellaneous items such as task lights and waste receptacles.
Though not included in the FF&E package, space has also been planned for User-provided items such as shop equipment, printers, TVs, etc. These items are identified on I-series drawings as “GFCI” (Government Furnished and Contractor Installed) items and included for coordination and installation purposes only.
First floor private and shared offices will receive modular freestanding (desk-based) laminate furniture, in an L-shape configuration. These desks include file/file and box/box/file storage, as well as overhead storage with tack board and task light. Power and data for private and shared offices will be accessed from wall locations.
Second floor private and shared offices will receive modular freestanding (desk-based) wood look laminate furniture, in an L-shape or U-shape configuration. These desks include file/file and box/box/file storage, as well as overhead storage with tack board and task light. Power and data for private and shared offices will be accessed from wall locations.
Open offices will be furnished with cubicles, with laminate work surfaces and painted metal storage. Power and data for open offices will be accessed via floor boxes, adjacent wall locations, or columns.
Power and Data will be accessed from adjacent wall, nearby column, or floor box.
An ergonomic task chair is provided at each desk. As well as guest seating, additional storage components are provided where space allows.
Conference rooms are to have a powered wood look laminate conference table with concealed power in the leg, and light task chairs around the table.
Additional guest seating available at the perimeter of the room where space allows.
Training rooms will have powered flip top tables with locking daisy chain for reconfiguration paired with a light task chair. A training table will be provided at the front of the room for the instructor along with a projection screen and white board.
Break rooms are to have laminate millwork, with requested "GFCI” (Government Furnished and Contractor Installed). Tables will be plastic laminate and plastic chairs will be provided for ease of cleanability.
DA Segment 5 Interior Design - 3
5.3.2 Architectural Finishes
Finish selections for the structure have been made to coordinate with the finish selections for the furniture in order to create a cohesive design.
Finishes specified are of a quality and durability appropriate for the facility.
5.3.2.1 Flooring
Vestibules at main entrances will have abrasive walk off carpet tile, which will extract debris and moisture from entering the building.
Durable commercial modular carpet tile will be used in classrooms, conference, as well as private and shared offices, and will be installed in a brick pattern.
Modular LVT (luxury vinyl tile) will be installed in most second-floor circulation, break rooms, lactation rooms, and first floor offices. LVT flooring requires no waxing and very little maintenance.
Shop spaces, hangar bay, and first floor circulation will receive epoxy five-part flooring. Support spaces such as janitor closets will receive sealed concrete.
Telecom rooms to have static dissipative flooring.
Restrooms are to porcelain tile flooring.
All flooring, except epoxy and porcelain, will be paired with rubber wall base, which will serve as a unifying neutral throughout the facility.
5.3.2.2 Walls
Most wall finishes will be neutral tones so they will not quickly become dated.
Accent paint colors, which are used sparingly, will incorporate the chosen color scheme provide visual interest.
Wall protection will be used throughout the facility as appropriate; resilient corner guards will be used on gypsum walls and stainless-steel corner guards will be used in more utilitarian areas such as the tool crib, shop spaces, and hangar. Wall guards will also be used in the Lobby, Corridors, Classrooms, Team Rooms, and Break Room, and mounted at the proper height to protect walls from furniture impact. In an effort for the resilient wall protection to be “unseen”, it has been specified in a coordinating color to the wall it is installed on.
Select walls will have print vinyl wall covering with custom graphics. These interior graphics aim to provide a functional, durable, visually appealing facility to enhance the User’s working environment, increase morale, and instill a sense of pride.
Roller shades, with 5% openness, have been paired with solid surface window stools and will be used throughout. In conference rooms and training rooms a double shade consisting of the 5% openness roller shade and a blackout shade will be used.
DA Segment 5 Interior Design - 4
Wood doors will be stained. Metal doors and all door frames will be painted in a semi-gloss sheen.
5.3.2.3 Ceilings
A white acoustical ceiling tile and grid system will be used in most administrative areas. Water resistant gypsum board ceilings will be used in all restrooms, and the shower areas of all restrooms will have an epoxy painted water resistant gypsum board ceiling. Any exposed structures will be painted.
5.3.2.4 Special Items
Laminate clad casework and solid surface laminate countertops are used in the Break Room and Lactation Room. In these areas, solid surface laminate countertops will be paired with under-mount stainless sinks.
Visual Display items are used throughout the facility.
Included as part of the FF&E are items such as marker boards and tack boards which are sized according to spatial needs.
Wall protection is used in the Janitor’s Closets on both sides of the mop sink and extend to 6’ above the finish floor tall.
A standardized system of signage including interchangeable components will be provided. Signage shall include identification, informational, and directional signage. Interior and exterior building signage shall comply with the requirements of the UFC 3-120-01.
Restroom specialty equipment includes shower curtain rods, folding shower seat, shower curtain, grab bars, liquid soap dispenser, mirrors, paper towels dispensers, hooks, seat cover dispenser, sanitary napkin disposal, toilet paper dispenser, and toilet partitions.
Janitor’s closets include mops sink and mop rack with storage shelf.
5.4 CONCLUSION
The Comprehensive Interior Design (CID) package includes Structural Interior Design (SID) and Furniture, Fixture & Equipment (FF&E). The goal of the CID is to provide a functional, durable, visually appealing facility to enhance the User’s working environment, increase morale, and instill a sense of pride. The primary criteria for finish and furniture selections is to create a unified, cohesive facility.
POINTS OF CONTACT
Tonya Wood, NCIDQ, ASID, IIDA, RID tonya.wood@meadhunt.com
Natalie Anderson natalie.anderson@meadhunt.com
MATCHLINE
SEE A1 / IF104
MATCHLINE
SEE A1 / IF105
M A T C H L
IN
E
S E E A I F
M A T C H L
IN
E
S E E A I F
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF101
O V E R A L L F
IR
S T F L O O R F F E P L A N
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
1/16" = 1'-0"A1
OVERALL FIRST FLOOR FF&E PLAN
D E S
IG
N
/2 /2
AIR
ELEC
MECH
EXIT PASSAGEWAY
VEST.
HANGAR DOCK #3
FIRE
118A
CORRIDOR
VEST.
COMM
SB1
STAIR
MACH RM
PMD
E1
ELEV
BRK RM/TORNADO
SHELTER
DOCK OFFICE
VEST.
WOMENS
MENS
JAN
WELL
125B
M
125C
W
127A
VEST
EQ-1 EQ-1
EQ-3
EQ-2 EQ-2
EQ-6
TB-1
(16)
CB-1
(32)
EQ-7
EQ-7
AV-1
EQ-5
CW-1
TW-1
WS-5
AV-2
M A T C H L
IN
E
S E E A I F
MATCHLINE
SEE A1 / IF104
CLOSET
58 SF
4.703
AV-1AV-2
EQ-4
4.708
EQ-7
DR-1
CT-1
AV-4
WB-1
4.802
EQ-9
(4)
AC-2
(2)
EQ-55
EQ-8
EQ-54
WS-11
EQ-56
I-701
A3
I-701
A8
127D
SERVER
SS-2
SS-2
SS-2
SS-2
SS-2 SS-2
SS-2
SS-2 SS-2
SS-2
SS-2 SS-2 SS-2
SS-2SS-2
SS-2 SS-2
SS-2
SS-2
SF-1
(2)
EQ-57
EQ-58
EQ-59
EQ-98
EQ-121
SF-1
(4)
EQ-150
EQ-149
4.703
CT-1
(12)
WS-11
TC-4 TC-4
CC-1
(8)
SS-2 SS-2 SS-2 SS-2 SS-2 SS-2
SS-2
WS-14
I-701
A3
AC-1
(2)
SL-1
(10)
SL-1
(9)
6.901
AC-1
(6) 6.901
I-701
F6
SF-1
(2)
LO STOR
FF&E PLAN GENERAL NOTES:
1. FURNITURE, FIXTURE & EQUIPMENT (FF&E) IS SHOWN FOR
COORDINATION, AND IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED (CFCI).
2. VERIFY FIELD CONDITIONS PRIOR TO ORDERING FF&E TO
ENSURE PROPER FIT OF ALL ITEMS.
3. GENERAL CONTRACTOR TO COORDINATE WITH FURNITURE
DEALER TO ALLOW BUILDING ACCESS FOR FIELD CONDITION
VERIFICATION.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL
CONNECTIONS TO THE BUILDING, INCLUDING J BOXES TO
SUPPORT FF&E. FURNITURE DEALER IS RESPONSIBLE FOR
THE ELECTRICAL HOOKUP OF ALL FF&E, INCLUDING WHIPS
FROM WALL CONNECTIONS TO THE FURNITURE AND
CONNECTIONS TO THE FURNITURE AND CONNECTING PRE-
WIRED PANELS, UP TO AND INCLUDING FACEPLATES.
5. INFORMATION TECHNOLOGY (IT) (PHONE / LAN ETC.) WIRING
TO BE PROVIDED BY OTHERS AFTER INSTALLATION:
COORDINATE WITH CONTRACTING OFFICER.
6. PROVIDE ALL FF&E COMPONENTS REQUIRED TO FULFILL THE
DESIGN INTENT OUTLINED IN THE FF&E PACKAGE, AND
ASSEMBLE FF&E PER MANUFACTURER'S WRITTEN
INSTRUCTIONS. FF&E PROVIDER MUST COORDINATE WITH
CONTRACTING OFFICER AS REQUIRED TO ENSURE THAT ALL
FF&E IS SUCCESSFULLY INSTALLED AND OPERATIONAL PRIOR
TO OCCUPANCY.
7. AWARDED FURNITURE DEALER TO PROVIDE SHOP DRAWINGS
WITH PANELS AND ELECTRICAL / COMM CONNECTIONS FOR
GOVERNMENT APPROVAL.
8. REFER TO FURNITURE SCHEDULE, SHEET I-602 FOR
INFORMATION.
9. REFER TO EQUIPMENT SCHEDULE, SHEET I-602 FOR
INFORMATION.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF102
F
IR
S T F L O O R F F E P L A N A R E A A
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
1/8" = 1'-0"A1
FIRST FLOOR FF&E PLAN - AREA A
EQUIPMENT LEGEND - AREA A1
TYPE
MARK DESCRIPTION COUNT
EQ-1 COMMERCIAL REFRIDGERATOR 2
EQ-2 FOOD VENDING 2
EQ-3 BEVERAGE VENDING 2
EQ-4 PRINTER 2
EQ-5 UNDER THE COUNTER REFRIGERATOR 1
EQ-6 WATER/ICE DISPENSER 1
EQ-7 TELEVISION, 55" 4
EQ-8 COFFEE MAKER 1
EQ-9 MICROWAVE 4
EQ-54 ACS SPACE 1
EQ-55 REVERSE OSMOSIS 1
EQ-56 COMPUTER CHARGING CABINET 1
EQ-57 WALK BEHIND FORK LIFT 1
EQ-58 WALK BEHIND FORK LIFT CHARGING STATION 1
EQ-59 SCISSOR LIFT CHARGING STATION 1
EQ-98 STANDUP FORK LIFT 1
EQ-121 JLG SCISSOR LIFT 1
EQ-149 ICE MACHINE WITH STORAGE BIN 1
EQ-150 COMMERCIAL FREEZER 1
FURNITURE LEGEND - AREA A1
TYPE
MARK DESCRIPTION COUNT
AC-1 TRASH RECEPTACLE 8
AC-2 RECYCLING RECEPTACLE 2
AC-3 TRASH RECEPTACLE, SMALL 17
AC-4 RECYCLING RECEPTACLE, SMALL 17
AV-1 DISPLAY BOARD, LOCKABLE 2
AV-2 MARKERBOARD, 4' X 6' 2
AV-4 WHITEBOARD, MOBILE 1
CB-1 CHAIR, BREAK ROOM 32
CC-1 CHAIR, CONFERENCE 8
CT-1 CHAIR, TASK 18
CW-1 CHAIR, WELLNESS 1
DR-1 DESK, RECTANGULAR 1
SF-1 STORAGE, LAT FILE 8
SL-1 STORAGE, LOCKERS TWO UNITS HIGH 19
SS-2 STORAGE, PALLET 96" X 48" X 120" 26
TB-1 TABLE, BREAK ROOM 16
TC-4 TABLE, CONFERENCE 60" X 65" 2
TW-1 TABLE, WELLNESS 1
WB-1 WORK BENCH, MOBILE 1
WS-5 WORKSTATION, 2 PERSONNEL 1
WS-11 WORKSTATION, 6 PERSONNEL 2
WS-14 WORKSTATION, 3 PERSONNEL 1
KEYED NOTES
4.703 EYEWASH STATION, SEE PLUMBING FOR MORE
INFORMATION.
4.802 SEE ARCHITECTURAL PLANS FOR JANITOR CLOSET
ACCESSORIES.
6.901 HAND WASH STATION REF. PLUMBING
D E S
IG
N
/2
DLA/IPV
COMPOSITE
VEST.
CORRIDOR
VEST.
CORRIDOR
HANGAR DOCK #1
VEST.
BRK RM/TORNADO
SHELTER
JAN
ELEC
015A
AIR
MECH
DOCK OFFICE
FIRE
COMM
021D
CLOSET
(NDI)
021A
WELL
021B
W
021C
M
MENS 023
WOMENS
EQ-7 EQ-7
CB-1
(24)
TB-1
(12)
EQ-1 EQ-1
EQ-3EQ-3
EQ-2EQ-2
EQ-6
AC-1
(2)
AV-1
TW-1
CW-1
EQ-4
AV-2
MATCHLINE
SEE A1 / IF105
M A T C H L
IN
E
S E E A I F
WS-4
4.703
4.703
EQ-5
EQ-7
DR-1
CT-1
AV-4
WB-1
EQ-9
(4)
4.802
AC-2
(2)
CT-1
(8)
EQ-55
EQ-8
CT-1
(2)
WS-5
EQ-56
WS-12
I-701
A8
I-701
A5
SS-3 SS-3 SS-3 SS-3 SS-3
SS-4SS-4SS-4
SS-4 SS-4 SS-4
SS-4 SS-4 SS-4 SS-4 SS-4
SS-3SS-3
SS-4SS-4SS-4
SS-4 SS-4 SS-4
SS-2SS-2SS-2
SF-1
(4)
SL-1
(11)
EQ-138 EQ-138
EQ-139
EQ-57
EQ-58
EQ-59
EQ-121
EQ-150
EQ-149
CORRIDOR
I-701
G1
SL-1
(11)
6.901
6.901
6.901
CB-2 CB-2
FF&E PLAN GENERAL NOTES:
1. FURNITURE, FIXTURE & EQUIPMENT (FF&E) IS SHOWN FOR
COORDINATION, AND IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED (CFCI).
2. VERIFY FIELD CONDITIONS PRIOR TO ORDERING FF&E TO
ENSURE PROPER FIT OF ALL ITEMS.
3. GENERAL CONTRACTOR TO COORDINATE WITH FURNITURE
DEALER TO ALLOW BUILDING ACCESS FOR FIELD CONDITION
VERIFICATION.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL
CONNECTIONS TO THE BUILDING, INCLUDING J BOXES TO
SUPPORT FF&E. FURNITURE DEALER IS RESPONSIBLE FOR
THE ELECTRICAL HOOKUP OF ALL FF&E, INCLUDING WHIPS
FROM WALL CONNECTIONS TO THE FURNITURE AND
CONNECTIONS TO THE FURNITURE AND CONNECTING PRE-
WIRED PANELS, UP TO AND INCLUDING FACEPLATES.
5. INFORMATION TECHNOLOGY (IT) (PHONE / LAN ETC.) WIRING
TO BE PROVIDED BY OTHERS AFTER INSTALLATION:
COORDINATE WITH CONTRACTING OFFICER.
6. PROVIDE ALL FF&E COMPONENTS REQUIRED TO FULFILL THE
DESIGN INTENT OUTLINED IN THE FF&E PACKAGE, AND
ASSEMBLE FF&E PER MANUFACTURER'S WRITTEN
INSTRUCTIONS. FF&E PROVIDER MUST COORDINATE WITH
CONTRACTING OFFICER AS REQUIRED TO ENSURE THAT ALL
FF&E IS SUCCESSFULLY INSTALLED AND OPERATIONAL PRIOR
TO OCCUPANCY.
7. AWARDED FURNITURE DEALER TO PROVIDE SHOP DRAWINGS
WITH PANELS AND ELECTRICAL / COMM CONNECTIONS FOR
GOVERNMENT APPROVAL.
8. REFER TO FURNITURE SCHEDULE, SHEET I -602 FOR
INFORMATION.
9. REFER TO EQUIPMENT SCHEDULE, SHEET I -602 FOR
INFORMATION.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
N
PLAN
NORTH
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF103
F
IR
S T F L O O R F F E P L A N A R E A B
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
1/8" = 1'-0"A1
FIRST FLOOR FF&E PLAN - AREA B
KEYED NOTES
4.703 EYEWASH STATION, SEE PLUMBING FOR MORE
INFORMATION.
4.802 SEE ARCHITECTURAL PLANS FOR JANITOR CLOSET
ACCESSORIES.
6.901 HAND WASH STATION REF. PLUMBING
FURNITURE LEGEND - AREA B
TYPE
MARK DESCRIPTION COUNT
AC-1 TRASH RECEPTACLE 2
AC-2 RECYCLING RECEPTACLE 2
AC-3 TRASH RECEPTACLE, SMALL 11
AC-4 RECYCLING RECEPTACLE, SMALL 11
AV-1 DISPLAY BOARD, LOCKABLE 1
AV-2 MARKERBOARD, 4' X 6' 1
AV-4 WHITEBOARD, MOBILE 1
CB-1 CHAIR, BREAK ROOM 24
CT-1 CHAIR, TASK 12
CW-1 CHAIR, WELLNESS 1
DR-1 DESK, RECTANGULAR 1
SF-1 STORAGE, LAT FILE 4
SL-1 STORAGE, LOCKERS TWO UNITS HIGH 22
SS-2 STORAGE, PALLET 96" X 48" X 120" 3
SS-3 STORAGE, PALLET 96" X 24" X 96" 7
SS-4 STORAGE, SHELVING 48" X 18" X 84" 17
TB-1 TABLE, BREAK ROOM 12
TW-1 TABLE, WELLNESS 1
WB-1 WORK BENCH, MOBILE 1
WS-4 WORKSTATION, 4 PERSONNEL 1
WS-5 WORKSTATION, 2 PERSONNEL 1
WS-12 WORKSTATION, 5 PERSONNEL 1
EQUIPMENT LEGEND - AREA B
TYPE
MARK DESCRIPTION COUNT
EQ-1 COMMERCIAL REFRIDGERATOR 2
EQ-2 FOOD VENDING 2
EQ-3 BEVERAGE VENDING 2
EQ-4 PRINTER 1
EQ-5 UNDER THE COUNTER REFRIGERATOR 1
EQ-6 WATER/ICE DISPENSER 1
EQ-7 TELEVISION, 55" 4
EQ-8 COFFEE MAKER 1
EQ-9 MICROWAVE 4
EQ-55 REVERSE OSMOSIS 1
EQ-56 COMPUTER CHARGING CABINET 1
EQ-57 WALK BEHIND FORK LIFT 1
EQ-58 WALK BEHIND FORK LIFT CHARGING STATION 1
EQ-59 SCISSOR LIFT CHARGING STATION 1
EQ-121 JLG SCISSOR LIFT 1
EQ-138 RESCUE BOOM LIFT 2
EQ-139 GOLF CART 1
EQ-149 ICE MACHINE WITH STORAGE BIN 1
EQ-150 COMMERCIAL FREEZER 1
D E S
IG
N
/2
HAZ STOR
TOOL CRIB
SC1
STAIR
FOM STORAGE
DOCK OFFICE
CORRIDOR
HANGAR DOCK #4
TOOL CHECKOUT
104C
TC OFFICE
100A
CORRIDOR
VEST.
CT-1
DL-1
CG-3
(2)
AV-2
M A T C H L
IN
E
S E E A I F
MATCHLINE
SEE A1 / IF102
EQ-4
WS-5AV-2
EQ-37
4.703
4.703
4.708
EQ-53
EQ-50
EQ-51
EQ-51
EQ-51
EQ-52
AV-2
AV-2
EQ-7
DR-1
CT-1
AV-4
WB-1
CT-1
(5)
AV-2
EQ-30 EQ-4
AV-2
WS-5
EQ-56
EQ-57
EQ-58
EQ-59
WS-2
WS-5
EQ-4
EQ-30
CT-1
(5)
AV-2
(PALLET
STORAGE)
WS-4
CT-1
(4)
E Q -6
EQ-31
(6)
101A
FOM OFF.
WS-2
WS-11
CT-1
(12)
WS-2
PSC
SL-1
(13)
EQ-62
EQ-63
EQ-65
EQ-47
SS-2SS-2
SS-2 SS-2
SF-1
(2)
EQ-52
EQ-68
EQ-69
SS-2
(3)
SF-1
(4)
SF-1
(6)
SS-5
(2)
E Q -6
EQ-147
EQ-12 EQ-12
SS-2
SS-2SS-2 SS-2
SS-2 SS-2SS-2 SS-2
SS-2
EQ-37 EQ-110EQ-108
EQ-143
EQ-47
EQ-151
EQ-158
EQ-64
SS-6
(2)
EQ-152
EQ-121
EQ-94 EQ-94
EQ-71
EQ-71
PSC
EQ-40
EQ-31
(3)
EQ-30
EQ-38
EQ-137EQ-136EQ-136EQ-136
EQ-161
(4)
EQ-160
(5)
EQ-159
SS-7
SS-7
EQ-137
EQ-137
EQ-47
(5)
EQ-47
(10)
SS-7
EQ-137
EQ-137
EQ-47
(5)
E Q -1
EQ-49
(5)
EQ-49
(5)
E Q -1
EQ-48
(5)
EQ-48
(5)
EQ-48
(3)
EQ-48
(3)
CT-5
(2)
EQ-163
(2)
EQ-164
(4)
EQ-165
EQ-165
EQ-162
(5)
WS-13
SF-1
I-701
A3
I-701
E8 I-701
E8
I-701
A8
I-701
A8
I-701
G6
I-701
A5
I-701
A8
I-701
E8
6.901
6.901
SL-1
(7)
I-701
G5
FF&E PLAN GENERAL NOTES:
1. FURNITURE, FIXTURE & EQUIPMENT (FF&E) IS SHOWN FOR
COORDINATION, AND IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED (CFCI).
2. VERIFY FIELD CONDITIONS PRIOR TO ORDERING FF&E TO
ENSURE PROPER FIT OF ALL ITEMS.
3. GENERAL CONTRACTOR TO COORDINATE WITH FURNITURE
DEALER TO ALLOW BUILDING ACCESS FOR FIELD CONDITION
VERIFICATION.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL
CONNECTIONS TO THE BUILDING, INCLUDING J BOXES TO
SUPPORT FF&E. FURNITURE DEALER IS RESPONSIBLE FOR
THE ELECTRICAL HOOKUP OF ALL FF&E, INCLUDING WHIPS
FROM WALL CONNECTIONS TO THE FURNITURE AND
CONNECTIONS TO THE FURNITURE AND CONNECTING PRE-
WIRED PANELS, UP TO AND INCLUDING FACEPLATES.
5. INFORMATION TECHNOLOGY (IT) (PHONE / LAN ETC.) WIRING
TO BE PROVIDED BY OTHERS AFTER INSTALLATION:
COORDINATE WITH CONTRACTING OFFICER.
6. PROVIDE ALL FF&E COMPONENTS REQUIRED TO FULFILL THE
DESIGN INTENT OUTLINED IN THE FF&E PACKAGE, AND
ASSEMBLE FF&E PER MANUFACTURER'S WRITTEN
INSTRUCTIONS. FF&E PROVIDER MUST COORDINATE WITH
CONTRACTING OFFICER AS REQUIRED TO ENSURE THAT ALL
FF&E IS SUCCESSFULLY INSTALLED AND OPERATIONAL PRIOR
TO OCCUPANCY.
7. AWARDED FURNITURE DEALER TO PROVIDE SHOP DRAWINGS
WITH PANELS AND ELECTRICAL / COMM CONNECTIONS FOR
GOVERNMENT APPROVAL.
8. REFER TO FURNITURE SCHEDULE, SHEET I-602 FOR
INFORMATION.
9. REFER TO EQUIPMENT SCHEDULE, SHEET I-602 FOR
INFORMATION.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF104
F
IR
S T F L O O R F F E P L A N A R E A C
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
1/8" = 1'-0"A1
FIRST FLOOR FF&E PLAN - AREA C
EQUIPMENT LEGEND - AREA C1
TYPE
MARK DESCRIPTION COUNT
EQ-4 PRINTER 3
EQ-7 TELEVISION, 55" 2
EQ-12 FLOOR SCRUBBER 2
EQ-30 SHREDDER 3
EQ-31 FLAMMABLE LIQUID STORAGE CABINET 9
EQ-37 FREEZER 2
EQ-38 METAL TABLE 1
EQ-40 WALK BEHIND FORK LIFT ll 1
EQ-47 VIDMAR 7 DRAWER CABINET W/ 7" DRAWER
HEIGHT
EQ-48 VIDMAR 12 DRAWER CABINET WITH 3 3/4"
DRAWER H
EQ-49 VIDMAR 12 DRAWER CABINET WITH 4 3/4"
DRAWER H
EQ-50 VIDMAR 7 DRAWER CABINET W/ 5 1/2" DRAWER
H
EQ-51 VIDMAR 10 DRAWER CABINET W/ 3 3/4"
DRAWER H
EQ-52 VIDMAR 9 DRAWER CABINET W/ 6" DRAWER H 2
EQ-53 VIDMAR 5 DRAWER CABINET W/ 9 3/4" DRAWER
H
EQ-56 COMPUTER CHARGING CABINET 1
EQ-57 WALK BEHIND FORK LIFT 1
EQ-58 WALK BEHIND FORK LIFT CHARGING STATION 1
EQ-59 SCISSOR LIFT CHARGING STATION 1
EQ-61 VERTICAL CAROUSEL STACKER 2
EQ-62 CORROSIVE CABINET 1
EQ-63 SMALL CHEMICAL CABINET 1
EQ-64 SMALL OXIDIZING CABINET 1
EQ-65 OXIDIZING AGENT CABINET 1
EQ-68 BARREL STORAGE SPILL PALLETS 1
EQ-69 YELLOW DRUM DOLLIES 1
EQ-71 EXTERNAL TANK LIFT 2
EQ-94 ELEC. MAN LIFT 2
EQ-108 WASTE COMPACTOR 1
EQ-110 WASTE COMPACTOR ll 1
EQ-121 JLG SCISSOR LIFT 1
EQ-136 METAL STORAGE CABINET 2 DOOR 5
EQ-137 METAL STORAGE CABINET 2 DOOR 5
EQ-143 BARREL LIFTER 1
EQ-147 ZAMBONI/AUTOSCRUBBER 1
EQ-151 PAINT SHAKER 1
EQ-152 CAN CRUSHER 1
EQ-158 WORKBENCH, WOOD TOP W/ SHELF 1
EQ-159 METAL OPEN STORAGE CABINET 1
EQ-160 METAL STORAGE CABINET 3 SHELF 5
EQ-161 SUPER ELECTRA SHELVING 72" x 24" x 86" 4
EQ-162 TOOL BOX 5
EQ-163 NITROGEN CART 2
EQ-164 GEAR / PRESSURE KITS 4
EQ-165 JACKS/DOLLY 2
FURNITURE LEGEND - AREA C1
TYPE
MARK DESCRIPTION COUNT
AC-3 TRASH RECEPTACLE, SMALL 27
AC-4 RECYCLING RECEPTACLE, SMALL 27
AV-2 MARKERBOARD, 4' X 6' 7
AV-4 WHITEBOARD, MOBILE 1
CG-3 CHAIR, GUEST OFFICE 2
CT-1 CHAIR, TASK 28
CT-5 CHAIR, TASK STOOL 2
DL-1 DESK, L-SHAPED 1
DR-1 DESK, RECTANGULAR 1
SF-1 STORAGE, LAT FILE 13
SL-1 STORAGE, LOCKERS TWO UNITS HIGH 19
SS-2 STORAGE, PALLET 96" X 48" X 120" 16
SS-5 STORAGE, SHELVING 36" X 24" X 84" 2
SS-6 STORAGE, WIRE SHELF 24" X 36" X 86" 2
SS-7 STORAGE, HEAVY DUTY 60" X 36" X 72" 3
WB-1 WORK BENCH, MOBILE 1
WS-2 WORKSTATION, 3 PERSONNEL 2
WS-4 WORKSTATION, 4 PERSONNEL 1
WS-5 WORKSTATION, 2 PERSONNEL 3
WS-11 WORKSTATION, 6 PERSONNEL 1
WS-13 WORKSTATION, 1 PERSONNEL 1
KEYED NOTES
4.703 EYEWASH STATION, SEE PLUMBING FOR MORE
INFORMATION.
6.901 HAND WASH STATION REF. PLUMBING
D E S
IG
N
/2
LANDING GEAR SHOP
ENGINE SHOP
DOCK OFFICE
TIRE (OPEN) SHOP
SHEET METAL
CORRIDOR
VEST.
HANGAR DOCK #2
MENS
WOMENS
JAN
CORRIDOR
EQ-4
MATCHLINE
SEE A1 / IF103
M A T C H L
IN
E
S E E A I F
EQ-16
EQ-17
EQ-18
EQ-20
EQ-22
EQ-23
EQ-24
EQ-25
EQ-26
EQ-29
4.703
4.703
EQ-42
EQ-43
EQ-44
DR-1
CT-1
AV-4
WB-1
EQ-7
5'-0"
3'-0" 4'-10 1/2"
EQ-11 EQ-11 EQ-11 EQ-11
EQ-11EQ-11EQ-11
EQ-56
EQ-105
EQ-101
EQ-157
EQ-112
EQ-113
EQ-154
EQ-153
EQ-11EQ-144EQ-144EQ-144
SL-1
(5)
EQ-57
EQ-58
EQ-59
EQ-98
EQ-121
EQ-91
EQ-166
(4)
EQ-145 EQ-145
SF-1
(3) I-701
A8
WS-5
CT-1
(5)
WS-13
I-701
A8
6.901
6.901
EQ-30
I-701
G5
FF&E PLAN GENERAL NOTES:
1. FURNITURE, FIXTURE & EQUIPMENT (FF&E) IS SHOWN FOR
COORDINATION, AND IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED (CFCI).
2. VERIFY FIELD CONDITIONS PRIOR TO ORDERING FF&E TO
ENSURE PROPER FIT OF ALL ITEMS.
3. GENERAL CONTRACTOR TO COORDINATE WITH FURNITURE
DEALER TO ALLOW BUILDING ACCESS FOR FIELD CONDITION
VERIFICATION.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL
CONNECTIONS TO THE BUILDING, INCLUDING J BOXES TO
SUPPORT FF&E. FURNITURE DEALER IS RESPONSIBLE FOR
THE ELECTRICAL HOOKUP OF ALL FF&E, INCLUDING WHIPS
FROM WALL CONNECTIONS TO THE FURNITURE AND
CONNECTIONS TO THE FURNITURE AND CONNECTING PRE-
WIRED PANELS, UP TO AND INCLUDING FACEPLATES.
5. INFORMATION TECHNOLOGY (IT) (PHONE / LAN ETC.) WIRING
TO BE PROVIDED BY OTHERS AFTER INSTALLATION:
COORDINATE WITH CONTRACTING OFFICER.
6. PROVIDE ALL FF&E COMPONENTS REQUIRED TO FULFILL THE
DESIGN INTENT OUTLINED IN THE FF&E PACKAGE, AND
ASSEMBLE FF&E PER MANUFACTURER'S WRITTEN
INSTRUCTIONS. FF&E PROVIDER MUST COORDINATE WITH
CONTRACTING OFFICER AS REQUIRED TO ENSURE THAT ALL
FF&E IS SUCCESSFULLY INSTALLED AND OPERATIONAL PRIOR
TO OCCUPANCY.
7. AWARDED FURNITURE DEALER TO PROVIDE SHOP DRAWINGS
WITH PANELS AND ELECTRICAL / COMM CONNECTIONS FOR
GOVERNMENT APPROVAL.
8. REFER TO FURNITURE SCHEDULE, SHEET I-602 FOR
INFORMATION.
9. REFER TO EQUIPMENT SCHEDULE, SHEET I-602 FOR
INFORMATION.
1/8" = 1'-0"A1
FIRST FLOOR FF&E PLAN - AREA D
KEYED NOTES
4.703 EYEWASH STATION, SEE PLUMBING FOR MORE
INFORMATION.
6.901 HAND WASH STATION REF. PLUMBING
EQUIPMENT LEGEND - AREA D
TYPE
MARK DESCRIPTION COUNT
EQ-4 PRINTER 1
EQ-7 TELEVISION, 55" 2
EQ-10 CHARGER FOR CART CADDY 8
EQ-11 TUGGER FOR STANDS 8
EQ-16 DRILL PRESS 1
EQ-17 SHRINKER STRETCHER 2
EQ-18 SHEET METAL RACK 1
EQ-20 SHEETMETAL BRAKE 8' - MANUAL 1
EQ-22 BAND SAW - 36" 1
EQ-23 HYDRAULIC PRESS BREAK 1
EQ-24 DIE RACK 1
EQ-25 MEDIA BLASTING CABINET 1
EQ-26 ROLLER - HYDRAULIC 1
EQ-29 OSCILATING SPINDLE AND DISC SANDER 1
EQ-30 SHREDDER 1
EQ-42 INFLATION SYSTEM 1
EQ-43 AIR DRYER 1
EQ-44 COMPRESSOR 1
EQ-56 COMPUTER CHARGING CABINET 1
EQ-57 WALK BEHIND FORK LIFT 1
EQ-58 WALK BEHIND FORK LIFT CHARGING STATION 1
EQ-59 SCISSOR LIFT CHARGING STATION 1
EQ-91 DOWN DRAFT TABLE 1
EQ-98 STANDUP FORK LIFT 1
EQ-101 SHEETMETAL SHEAR 8' 1
EQ-105 HOT DIMPLING MACHINE 1
EQ-112 SCRAP SHEETMETAL TRASH BIN 1
EQ-113 SCRAP SHEETMETAL CABINET 1
EQ-121 JLG SCISSOR LIFT 1
EQ-144 FLATBED TUG 3
EQ-145 MED. CAP. TOW TUG 2
EQ-153 ROLLER - MANUAL 1
EQ-154 PRESS - MANUAL 1
EQ-157 MLG SAW AND BLADES 1
EQ-166 GEAR HOLDING FIXTURE 4
FURNITURE LEGEND - AREA D
TYPE
MARK DESCRIPTION COUNT
AC-3 TRASH RECEPTACLE, SMALL 5
AC-4 RECYCLING RECEPTACLE, SMALL 5
AV-4 WHITEBOARD, MOBILE 1
CT-1 CHAIR, TASK 6
DR-1 DESK, RECTANGULAR 1
SF-1 STORAGE, LAT FILE 3
SL-1 STORAGE, LOCKERS TWO UNITS HIGH 5
WB-1 WORK BENCH, MOBILE 1
WS-5 WORKSTATION, 2 PERSONNEL 2
WS-13 WORKSTATION, 1 PERSONNEL 1
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF105
F
IR
S T F L O O R F F E P L A N A R E A D
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
D E S
IG
N
/2
SFTWR
SCHED OFF 207
MECH
BRK
AMXS
CORRIDOR
209B
OFFICE
209A
OFFICE
COMM
218J
CONF
OPEN OFFICE
ELEC
202B
OFFICE
202H
OFFICE
202I
OFFICE
202A
ELEC
202K
COLLAB
M
W
HANGAR DOCK #1
HANGAR DOCK #2
HANGAR DOCK #3
HANGAR DOCK #4
218G
OFFICE
218F
OFFICE
218E
OFFICE
218D
OFFICE
218C
OFFICE
218B
OFFICE
218A
OFFICE
218I
CONF
CTR TRNG
MENS
WOMENS
JAN
218H
COPY
RECYCLING
E2
ELEV
STOR
SB2
STAIR
SC2
STAIR
202G
COPY/FILE
SA1
STAIR
202C
OFFICE
202D
OFFICE
202E
OFFICE
202F
OFFICE
218K
ELEC
202J
OFFICE
MATCHLINE
SEE A1 / IF108 MATCHLINE
SEE A1 / IF107
214B
DEPUTY
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF106
O V E R A L L S E C O N D F L O O R F F E P L A N
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
1/16" = 1'-0"A1
OVERALL SECOND FLOOR FF&E PLAN
D E S
IG
N
/2
SCHED OFF
MECH
BRK
AMXS
CORRIDOR
209B
OFFICE
209A
OFFICE
218J
CONF
ELEC
M
W
218G
OFFICE
218F
OFFICE
218E
OFFICE
218D
OFFICE
218C
OFFICE
218B
OFFICE
218A
OFFICE
218I
CONF
MENS
WOMENS
JAN
218H
COPY
E2
ELEV
STOR
SB2
STAIR
SA1
STAIR
218K
ELEC
CTR TRNG
CC-2
(6)
TC-2 TC-3
CG-1
(4)
CC-2
(11)
AV-5
EQ-4
WS-7
AV-2
WS-9
AV-2
WS-6
WS-7
AV-2
CG-2
(2)
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3
CT-3
DL-2
CG-2
(2)
AV-2
AC-1
(2)
AC-2
(2)
CB-1
(24)
TB-1
(12)
EQ-7EQ-7
EQ-9
(4)
EQ-8
EQ-1
EQ-6
WS-8
CT-2
(12)
EQ-4
AV-2
AV-1
AV-2
AV-2
DL-2
CT-3 CG-2
(2)
MATCHLINE
SEE A1 / IF108
AV-5
EQ-7
4.802
CT-2
(52)
AV-5
AV-5
EQ-7
TT-1
(6)
CR-1
(9)
EQ-55
CT-3
CG-2
(2)
DL-2
STOR
WS-3
CT-3
TL-1
CG-1
(4)
(2)
CG-2
(2)
DL-2
CT-3AV-2
CG-2
(2)
DL-2
CT-3AV-2
DU-1
CG-2
(6)
TC-5
AV-2
CT-4
214C
COMMAND SUITE
214B
DEPUTY
RECEPTION
214A
DEPUTY
SF-1
(2)
SF-1
(2)
EQ-150
AC-1
AC-2
AC-3
AC-4
AC-3
AC-4
I-701
C5
I-701
E4
I-701
C1
I-701
C5
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
E1
I-701
F5
AC-5AC-6
CG-1
(8)
FF&E PLAN GENERAL NOTES:
1. FURNITURE, FIXTURE & EQUIPMENT (FF&E) IS SHOWN FOR
COORDINATION, AND IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED (CFCI).
2. VERIFY FIELD CONDITIONS PRIOR TO ORDERING FF&E TO
ENSURE PROPER FIT OF ALL ITEMS.
3. GENERAL CONTRACTOR TO COORDINATE WITH FURNITURE
DEALER TO ALLOW BUILDING ACCESS FOR FIELD CONDITION
VERIFICATION.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL
CONNECTIONS TO THE BUILDING, INCLUDING J BOXES TO
SUPPORT FF&E. FURNITURE DEALER IS RESPONSIBLE FOR
THE ELECTRICAL HOOKUP OF ALL FF&E, INCLUDING WHIPS
FROM WALL CONNECTIONS TO THE FURNITURE AND
CONNECTIONS TO THE FURNITURE AND CONNECTING PRE-
WIRED PANELS, UP TO AND INCLUDING FACEPLATES.
5. INFORMATION TECHNOLOGY (IT) (PHONE / LAN ETC.) WIRING
TO BE PROVIDED BY OTHERS AFTER INSTALLATION:
COORDINATE WITH CONTRACTING OFFICER.
6. PROVIDE ALL FF&E COMPONENTS REQUIRED TO FULFILL THE
DESIGN INTENT OUTLINED IN THE FF&E PACKAGE, AND
ASSEMBLE FF&E PER MANUFACTURER'S WRITTEN
INSTRUCTIONS. FF&E PROVIDER MUST COORDINATE WITH
CONTRACTING OFFICER AS REQUIRED TO ENSURE THAT ALL
FF&E IS SUCCESSFULLY INSTALLED AND OPERATIONAL PRIOR
TO OCCUPANCY.
7. AWARDED FURNITURE DEALER TO PROVIDE SHOP DRAWINGS
WITH PANELS AND ELECTRICAL / COMM CONNECTIONS FOR
GOVERNMENT APPROVAL.
8. REFER TO FURNITURE SCHEDULE, SHEET I-602 FOR
INFORMATION.
9. REFER TO EQUIPMENT SCHEDULE, SHEET I-602 FOR
INFORMATION.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF107
S E C O N D F L O O R F F E P L A N A R E A A
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
1/8" = 1'-0"A1
SECOND FLOOR FF&E PLAN - AREA A
KEYED NOTES
4.802 SEE ARCHITECTURAL PLANS FOR JANITOR CLOSET
ACCESSORIES.
EQUIPMENT LEGEND - AREA A2
TYPE
MARK DESCRIPTION COUNT
EQ-1 COMMERCIAL REFRIDGERATOR 1
EQ-4 PRINTER 2
EQ-6 WATER/ICE DISPENSER 1
EQ-7 TELEVISION, 55" 4
EQ-8 COFFEE MAKER 1
EQ-9 MICROWAVE 4
EQ-55 REVERSE OSMOSIS 1
EQ-150 COMMERCIAL FREEZER 1
FURNITURE LEGEND - AREA A2
TYPE
MARK DESCRIPTION COUNT
AC-1 TRASH RECEPTACLE 3
AC-2 RECYCLING RECEPTACLE 3
AC-3 TRASH RECEPTACLE, SMALL 79
AC-4 RECYCLING RECEPTACLE, SMALL 79
AC-5 TRASH RECEPTACLE, 55 GAL 2
AC-6 RECYCLING RECEPTACLE, 55 GAL 2
AV-2 MARKERBOARD, 4' X 6' 15
AV-5 MARKERBOARD, PRESENTATION 3
CB-1 CHAIR, BREAK ROOM 24
CC-2 CHAIR, CONFERENCE 18
CG-1 CHAIR, GUEST 17
CR-1 CHAIR, TRAINING 9
CT-2 CHAIR, TASK OFFICE 64
CT-3 CHAIR, TASK OFFICE 12
CT-4 CHAIR, TASK COMMANDER 1
DL-2 DESK, L-SHAPED 11
DU-1 DESK, U SHAPED 1
SF-1 STORAGE, LAT FILE 4
TB-1 TABLE, BREAK ROOM 12
TC-2 TABLE, CONFERENCE 42" X 72" 1
TC-3 TABLE, CONFERENCE 42" X 144" 1
TC-5 TABLE, OFFICE MEETING 1
TL-1 TABLE, LOUNGE 2
TT-1 TABLE, TRAINING 30" X 72" 3
WS-3 WORKSTATION, 6' x 6' RECEPTION 1
WS-6 WORKSTATION, 12 PERSONNEL 1
WS-7 WORKSTATION, 14 PERSONNEL 2
WS-8 WORKSTATION, 12 PERSONNEL 1
WS-9 WORKSTATION, 13 PERSONNEL 1
D E S
IG
N
/2
SFTWR
CORRIDOR
COMM
OPEN OFFICE
202B
OFFICE
202J
OFFICE
202H
OFFICE
202I
OFFICE
202A
ELEC
202K
COLLAB
HANGAR DOCK #4
CTR TRNG
SC2
STAIR
202G
COPY/FILE
202C
OFFICE
202D
OFFICE
202E
OFFICE
202F
OFFICE
CG-1
(8)
AV-2
CC-2
(10)
TC-1
WS-1
WS-1
AV-2
AV-2
EQ-4
CG-2
(2)
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3
AV-2
DL-2
CT-3
AV-2
CG-2
(2)
DL-2
CT-3AV-2CG-2
(2)
DL-2
CT-3AV-2CG-2
(2)
DL-2
CT-3AV-2CG-2
(2)
DL-2
CT-3AV-2CG-2
(2)
MATCHLINE
SEE A1 / IF107
WS-10 WS-10
TC-4 TC-4
CC-1CC-1
(8)
CT-1
(20)
TT-1
(6) TT-2
EQ-7
AV-5
CR-1
(10)
SF-1
(2)
SF-1
(2)
AC-3 AC-4
I-701
A1
I-701
A1
I-701
C9
I-701
C9
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
I-701
J1
FF&E PLAN GENERAL NOTES:
1. FURNITURE, FIXTURE & EQUIPMENT (FF&E) IS SHOWN FOR
COORDINATION, AND IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED (CFCI).
2. VERIFY FIELD CONDITIONS PRIOR TO ORDERING FF&E TO
ENSURE PROPER FIT OF ALL ITEMS.
3. GENERAL CONTRACTOR TO COORDINATE WITH FURNITURE
DEALER TO ALLOW BUILDING ACCESS FOR FIELD CONDITION
VERIFICATION.
4. GENERAL CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL
CONNECTIONS TO THE BUILDING, INCLUDING J BOXES TO
SUPPORT FF&E. FURNITURE DEALER IS RESPONSIBLE FOR
THE ELECTRICAL HOOKUP OF ALL FF&E, INCLUDING WHIPS
FROM WALL CONNECTIONS TO THE FURNITURE AND
CONNECTIONS TO THE FURNITURE AND CONNECTING PRE-
WIRED PANELS, UP TO AND INCLUDING FACEPLATES.
5. INFORMATION TECHNOLOGY (IT) (PHONE / LAN ETC.) WIRING
TO BE PROVIDED BY OTHERS AFTER INSTALLATION:
COORDINATE WITH CONTRACTING OFFICER.
6. PROVIDE ALL FF&E COMPONENTS REQUIRED TO FULFILL THE
DESIGN INTENT OUTLINED IN THE FF&E PACKAGE, AND
ASSEMBLE FF&E PER MANUFACTURER'S WRITTEN
INSTRUCTIONS. FF&E PROVIDER MUST COORDINATE WITH
CONTRACTING OFFICER AS REQUIRED TO ENSURE THAT ALL
FF&E IS SUCCESSFULLY INSTALLED AND OPERATIONAL PRIOR
TO OCCUPANCY.
7. AWARDED FURNITURE DEALER TO PROVIDE SHOP DRAWINGS
WITH PANELS AND ELECTRICAL / COMM CONNECTIONS FOR
GOVERNMENT APPROVAL.
8. REFER TO FURNITURE SCHEDULE, SHEET I-602 FOR
INFORMATION.
9. REFER TO EQUIPMENT SCHEDULE, SHEET I-602 FOR
INFORMATION.
C
A B
D
AN
R P
M
E L
I
I R Y
N G
E S
I
D
NOT FOR
CONSTRUCTION
SCALE:
US Army Corps of Engineers
SHEET OF
SHEET ID
U S A R M Y C O R P S O F E N G
IN
E E R S
D R A W N B Y
D E S
IG
N E D B Y
S U B M
IT
T E D B Y
S
IZ
E
C H E C K E D B Y
X
IS
S U E D A T E
C O N T R A C T N O
S O L
IC
IT
A T
IO
N N O
M A R K
D E S C R
IP
T
IO
N
D A T E
D A T E
M A R K
D E S C R
IP
T
IO
N
A
B
C
D
E
F
G
H
J
2 3 4 5 6 7 8 9 10 11 12
4'-0" 8'-0" 16'-0"
1/8" = 1'-0"
KEYPLAN
Mead & Hunt, Inc.
2440 Deming Way Middleton, WI 53562 phone: 608-273-6380 meadhunt.com
T U L S A D
IS
T R
IC
T
E S T S T R E E T
T U L S A O K -4
E N G
IN
E E R
IN
G
C O N S T R U C T
IO
N D
IV
IS
IO
N
E N G
IN
E E R
IN
G B R A N C H
W B V -1 -D -0
W B V -2 -D -0
S N A L L
T W O O D
S L A W L E Y
A M A L A N O W S K Y
IF108
S E C O N D F L O O R F F E P L A N A R E A C
T
IN
K E R A
IR
F O R C E B A S E O K
N O V E M B E R
D E S
IG
N
B O M B E R A G
IL
E C O M M O N H A N G A R
W W Y K
1/8" = 1'-0"A1
SECOND FLOOR FF&E PLAN - AREA C
FURNITURE LEGEND - AREA C2
TYPE
MARK DESCRIPTION COUNT
AC-3 TRASH RECEPTACLE, SMALL 29
AC-4 RECYCLING RECEPTACLE, SMALL 29
AV-2 MARKERBOARD, 4' X 6' 11
AV-5 MARKERBOARD, PRESENTATION 1
CC-1 CHAIR, CONFERENCE 8
CC-2 CHAIR, CONFERENCE 10
CG-1 CHAIR, GUEST 8
CG-2 CHAIR, GUEST OFFICE 44
CR-1 CHAIR, TRAINING 10
CT-1 CHAIR, TASK 20
CT-3 CHAIR, TASK OFFICE 8
DL-2 DESK, L-SHAPED 8
SF-1 STORAGE, LAT FILE 4
TC-4 TABLE, CONFERENCE 60" X 65" 2
TT-1 TABLE, TRAINING 30" X 72" 6
TT-2 TABLE, TRAINING 30" X 60" 1
WS-1 WORKSTATION, 6 PERSONNEL 2
WS-10 WORKSTATION, 4 PERSONNEL 2
EQUIPMENT LEGEND - AREA C2
TYPE
MARK DESCRIPTION COUNT
EQ-4 PRINTER 1