SECTION_05_05_10_Metal_Galvanizing.docx
DOCX document 21 KB Posted
- Attached to
- Dugway Proving Ground, Utah Road Maintenance
- Solicitation number
- W911S6-17-B-0001
About this file
SECTION 05 05 10 METAL GALVANIZING
View the file
Other files
Show 40 more
Latest 50 of 87 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 05 05 10
SECTION 05 05 10
METAL GALVANIZING
| PART 1 | GENERAL |
| 1.1 | SECTION INCLUDES |
| A. | Application of a zinc coating on fabricated metal items. |
| B. | Repair of damaged galvanized surfaces. |
| 1.2 | REFERENCES |
| A. | ASTM A 123: Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products. |
| B. | ASTM A 153: Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware. |
| C. | ASTM A 780: Standard Practice for Repair of Damaged Hot-Dip Galvanized Coatings. |
| D. | ASTM B 6: Standard Specification for Zinc (Slab Zinc). |
| E. | ASTM E 376: Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy-Current (Electromagnetic) Test Methods. |
| F. | FS TT-P-641: Primer Coating, Zinc Dust - Zinc Oxide (for Galvanized Surfaces). |
| G. | MIL P-21035: Paint, High Zinc Dust Content, Galvanizing Repair. |
| 1.3 | QUALITY ASSURANCE |
| A. | When requested, verify weight of zinc coating in accordance with ASTM E 376. |
| PART 2 | PRODUCTS |
| 2.1 | ZINC METAL |
| A. | Use zinc for coating that conforms to ASTM B 6 and is at least equal to the grade designated as "Prime Western". |
| PART 3 | EXECUTION |
| 3.1 | GALVANIZING |
| A. | Provide a zinc coating for those items indicated or specified to be galvanized as follows: |
| 1. | ASTM A 123 for galvanizing rolled, pressed and forged steel shapes, plates, bars and strips 1/8 inch thick and heavier. |
| 2. | ASTM A 153 for galvanizing iron and steel hardware. |
| 3.2 | WEIGHT OF COATING |
| A. | Apply zinc on 1/8 inch to 3/16 inch thick steel at a rate of at least 2-ounces per square foot of surface area. |
| B. | Apply zinc on 1/4 inch and thicker steels at a rate of at least 2.3 ounces per square foot with no individual test measuring less than 2-ounces per square foot of surface area. |
| 3.3 | REPAIR OF DAMAGED COATING |
| A. | Repair all shop damaged galvanized surfaces by the metallizing, hot stick or zinc rich paint, ASTM C 780 process. |
| B. | Repair field damaged, cut, burned or uncoated surfaces in the field by coating with a dust-zinc oxide paint conforming to FS TT-P-641 or MIL P-21035. |
END OF SECTION
METAL GALVANIZING Page 1