This document is a technical specification for acoustical wall panels for the FY24 MCON P-614 Joint Consolidated Communications Center at Andersen Air Force Base in Guam. The specification details precise requirements for fabric-wrapped acoustical wall panels, including panel dimensions of 24 inches wide by 48 inches high, with a thickness designed to achieve a Noise Reduction Coefficient (NRC) range of 0.70-0.85 for 1-inch panels and 0.90-1.00 for 2-inch panels. The panels must be constructed with a seamless, plain woven 2-ply 100% polyester fabric covering, have a Class A fire rating, and use either fiber glass or mineral fiber as the substrate.
Key technical requirements include using panels with chamfered edges, a standard acoustical core, and mounting via the manufacturer's concealed spline method. The specification mandates that fabric panels contain a minimum of 50% recycled polyester, have no added urea-formaldehyde resins, and meet California Department of Public Health emissions standards. Fabric must have specific performance characteristics, including a minimum tear strength of 29 pounds, tensile strength of 150 pounds, and light fastness of approximately 40 hours. Submittals require government approval for detail drawings, product data, samples, and documentation of recycled content and indoor air quality.
View the file
Other files
Show 40 more
Latest 50 of 89 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FY24 MCON P-614 JOINT CONSOLIDATED COMMUNICATIONS CENTER 1737021
JOINT REGION MARIANAS, ANDERSEN AIR FORCE BASE
SECTION 09 84 20
ACOUSTICAL WALL PANELS
08/16, CHG 1: 08/18
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN ASSOCIATION OF TEXTILE CHEMISTS AND COLORISTS (AATCC)
AATCC 16 (2004; E 2008; E 2010) Colorfastness to Light
ASTM INTERNATIONAL (ASTM)
ASTM C423 (2023) Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
ASTM D5034 (2009; R 2017) Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test)
ASTM E84 (2023) Standard Test Method for Surface Burning Characteristics of Building Materials
CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)
CDPH SECTION 01350 (2017; Version 1.2) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2021; TIA 21-1) Life Safety Code
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Approved Detail Drawings; G
SD-03 Product Data
Installation
SECTION 09 84 20 Page 1
Amendment 0011 09 84 20 ACOUSTICAL WALL PANELS, dated May 7, 2025
Acoustical Wall Panels; G
Recycled Content for Fabric Panels; S
Indoor Air Quality for Fabric Panels; S
SD-04 Samples
Acoustical Wall Panels; G
SD-11 Closeout Submittals
Warranty
1.3 DELIVERY, STORAGE, AND HANDLING
Protect materials delivered and placed in storage from the weather, humidity and temperature variations, dirt, dust, or other contaminants.
1.4 WARRANTY
Provide manufacturer's standard performance guarantees or warranties that extend beyond a one year period.
PART 2 PRODUCTS
2.1 SYSTEM DESCRIPTION
2.1.1 Design
Provide fabric wrapped mineral / glass-fiber core acoustical wall panel materials in the manufacturer's standard sizes and finishes of the type, design and configuration indicated.
2.1.1.1 Indoor Air Quality
Fabric Panels must contain a minimum of 50 percent recycled polyester.
Provide data identifying percentage of recycled content for fabric panels.
Fabric panel products must contain no added urea-formaldehyde resins.
Products must meet emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type). Provide validation of indoor air quality for fabric panels.
2.2 FABRIC COVERED ACOUSTICAL WALL PANELS
Provide acoustical wall panels consisting of prefinished, factory assembled, seamless fabric covered, fiber glass or mineral fiber core system as described below manufactured to the dimensions and configurations shown on the approved detail drawings; submit drawings showing plan locations, elevations and details of method of anchorage, location of doors and other openings, base detail and shape and thickness of materials. Perimeter edges must be reinforced by either an aluminum frame or a formulated resin edge hardener. Acoustical wall panels must comply with the interior finish requirements of NFPA 101 . Submit manufacturer's descriptive data and catalog cuts; fabric and vinyl swatches, minimum 18 inches wide by 24 inches long 3 samples of each color range specified; and certificates of compliance from an independent laboratory accredited by the National Laboratory Accreditation Program of
SECTION 09 84 20 Page 2 the National Institute of Standards. A label or listing from the testing laboratory will be acceptable evidence of compliance. Wall panels must conform to the following:
2.2.1 Panel Width
Widths must be 24 inches End panels may vary in width as necessary to cover wall.
2.2.2 Panel Height
Heights must be 48 inches.
2.2.3 Thickness
Panel thickness as required to meet the indicated NRC range.
2.2.4 Fabric Covering
Seamless plain woven 2-ply 100 percent polyester, minimum 15 ounces/linear yard. Tear strength a minimum 29 pounds. Tensile strength 150 pounds minimum in accordance with ASTM D5034. Stretch fabric covering free of wrinkles and then bond to the edges and back or bond directly to the panel face, edges, and back of panel a minimum distance standard with the manufacturer. Light fastness (fadeometer) approximately 40 hours in accordance with AATCC 16.
2.2.5 Fire Rating for the Complete Composite System
Class A, 200 or less smoke density and flame spread less than 25, when tested in accordance with ASTM E84.
2.2.6 Substrate
Fiber glass or mineral fiber
2.2.7 Noise Reduction Coefficient (NRC) Range
0.70-0.85 for 1 inch thick panels and 0.90-1.00 for 2 inch thick panels ;
ASTM C423
2.2.8 Edge Detail
Chamfered edge with fabric wrapped on all sides.
2.2.9 Core Type
Standard acoustical core
2.2.10 Mounting Acoustical Panels
Mount acoustical panels by manufacturer's standard concealed spline.
2.3 COLOR
As indicated. Color listed is not intended to limit the selection of equal colors from other manufacturers.
SECTION 09 84 20 Page 3
PART 3 EXECUTION
3.1 SURFACE CONDITIONS
Must be clean, smooth, oil free and prepared in accordance with panel manufacturer's instructions. Do not begin installation until all wet work, such as, plastering, painting, and concrete are completely dry.
3.2 INSTALLATION
Panel installation must be by personnel familiar with and normally engaged in installation of acoustical wall panels. Apply panels in accordance with the manufacturer's installation instructions. Submit manufacturer's installation instructions and recommended cleaning instructions.
3.3 CLEANING
Following installation, clean dirty or stained panel surfaces in accordance with manufacturer's instructions and leave free from defects.
Remove and replace panels that are damaged, discolored, or improperly installed.
-- End of Section --
SECTION 09 84 20 Page 4
| 09 84 20 - ACOUSTICAL WALL PANELS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 DELIVERY, STORAGE, AND HANDLING |
| 1.4 WARRANTY |
| PART 2 PRODUCTS |
| 2.1 SYSTEM DESCRIPTION |
| 2.1.1 Design |
| 2.1.1.1 Indoor Air Quality |
| 2.2 FABRIC COVERED ACOUSTICAL WALL PANELS |
| 2.2.1 Panel Width |
| 2.2.2 Panel Height |
| 2.2.3 Thickness |
| 2.2.4 Fabric Covering |
| 2.2.5 Fire Rating for the Complete Composite System |
| 2.2.6 Substrate |
| 2.2.7 Noise Reduction Coefficient NRC Range |
| 2.2.8 Edge Detail |
| 2.2.9 Core Type |
| 2.2.10 Mounting Acoustical Panels |
2.3 COLOR
| PART 3 EXECUTION |
| 3.1 SURFACE CONDITIONS |
| 3.2 INSTALLATION |
| 3.3 CLEANING |