A-500 - WALL SECTIONS.pdf

PDF 1 MB Posted

Attached to
P1112 B72 Resiliency Improvements, Portsmouth Naval Shipyard (PNSY), Kittery, Maine
Solicitation number
N4008526R0005
Issued by

About this file

This is an architectural drawing sheet for the Portsmouth Naval Shipyard in Kittery, Maine, specifically detailing wall sections for the B72 Resiliency Improvements project. The drawing is classified as unclassified and was prepared by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic under contract number TBD with project number P-1112 B72 Resiliency Improvements. The sheet (A-500) contains multiple wall section details at various scales (3/4" = 1'-0" and 1 1/2" = 1'-0") showing typical construction assemblies for the B72-Addition structure, including pump rooms B, S, and adjacent spaces.

The wall sections illustrate construction details incorporating standing seam metal roof systems, 4-inch insulated metal wall panels, 8-inch concrete back-up walls, 2 3/8-inch concrete-faced rigid insulation boards, vapor barriers, structural frames by MBM, and various fire-rated wall assemblies (2-hour and 3-hour rated). The drawing includes termination bar details and notes specifying that girt spacing will be determined by MBM and that air-vapor barriers must be sealed to all roof fabric and penetrating structures. The revision date is August 25, 2020, with the drawing file dated April 10, 2026, indicating ongoing project management of these specifications for naval shipyard resiliency improvements.

View the file

Other files

File Type Posted
N4008526R0005 Amendment 0010.pdf PDF
Attachment H - Price Proposal Form Revision 3.docx DOCX document
N4008526R0005 Amendment 0009.pdf PDF
GC100A_Milestones and Coordination Requirements_20260528.pdf PDF
N4008526R0005 Amendment 0008.pdf PDF
31 00 00.00 22_Attachment A_Salt Water Tunnels and Building 72_Historical Drawings.pdf PDF
00 01 15_RevAmend08.pdf PDF
Attachment H - Price Proposal Form Revision 2.docx DOCX document
01 11 00.00 22_RevAmend08.pdf PDF
098 S-502 Rev. 1 P-1112.pdf PDF
P-1112 Drawing Updates 2026-04-29.pdf PDF
072 S-001 Rev. 1 P-1112.pdf PDF
086 S-124 Rev. 1 P-1112.pdf PDF
J and A ML-26-51 P1112 B72 Resiliency Controller Redacted.pdf PDF
N4008526R0005 Amendment 0007.pdf PDF
A-450 - ENLARGED PLAN DETAILS.pdf PDF
101 S-505 Rev. 1 P-1112.pdf PDF
102 S-506 Rev. 1 P-1112.pdf PDF
Lifting_Eye_Comp_Cut_Sheet_LIFTMAX-PEP-00100 (050726).pdf PDF
41 22 13.14.pdf PDF
N4008526R0005 Amendment 0006.pdf PDF
N4008526R0005 Amendment 0005.pdf PDF
PPI 98 - V-104 Archaeology Area Outlined.pdf PDF
PPI 198 - 26 56 00.pdf PDF
N4008526R0005 Amendment 0004.pdf PDF
PPI 203 - COMNAVREGMIDLANTINST_11320_11B.pdf PDF
PPIs 181.182.183.208 - Schedule of Special Inspections.pdf PDF
PPI 137 - 46 30 00 Attachments 1 to 4.pdf PDF
PPI 91 - Sheet 7 of 226 - H-101.pdf PDF
PPI 166 - Air Valve Detail.pdf PDF
PPI 200 - 32 17 23.pdf PDF
Option 13 - Accessory Structure_REV2.pdf PDF
N4008526R0005 Amendment 0003.pdf PDF
N4008526R0005 Amendment 0002.pdf PDF
P-1112 B72 Resiliency Improvement Site Visit Log.pdf PDF
N4008526R0005 Amendment 0001.pdf PDF
DBIDS 5500 Form.docx DOCX document
Attachment H - Price Proposal Form.docx DOCX document
Attachment G - Small Business Subcontracting Plan (SBSP) Template.docx DOCX document
Attachment C - Construction Experience Data Sheet.docx DOCX document
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment A - PPI Log Template.xlsx XLSX spreadsheet
N4008526R0005.pdf PDF
P-1112 Drawings.pdf PDF
Attachment E - Historical Small Business Utilization.docx DOCX document
DBIDS 5512 Form.pdf PDF
Memorandum - Bidding Notes P-1112.pdf PDF
P-1112 Specifications.pdf PDF
Attachment F - Small Business Participation Commitment Document (SBPCD).docx DOCX document
Attachment D - Past Performance Questionnaire.docx DOCX document
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B72-ADDITION

11' - 0 11/16"

PUMP ROOM B

INTERIOR

EXTERIOR

CONC. SLAB. SEE

STRUCTURAL DWGS.

B72-ADDITION-ROOF

13' - 0"

STANDING SEAM METAL ROOF

A-501

F

A-502

I

A-501

B

7.2

VAPOR BARRIER

3.1

B72-ADDITION

11' - 0 11/16"

PUMP ROOM B

PUMP ROOM S

2HR RATED WALL ASSEMBLY

A-503

B

3HR RATED WALL

ASSEMBLY

B

A-502

B72-ADDITION

11' - 0 11/16"

PUMP ROOM B

INTERIOR EXTERIOR

CONC. SLAB. SEE

STRUCTURAL DWGS.

A-502

C

4" INSULATED METAL WALL PANEL

STUCTURAL FRAME BY MBM

8" CONCRETE

BACK-UP WALL

2 3/8" CONCRETE FACED

RIGID INSULATION BOARDA-503

E

J

VAPOR BARRIER

D

B72-ADDITION

11' - 0 11/16"

INTERIOREXTERIOR

CONC. SLAB. SEE

STRUCTURAL DWGS.

GRADE. VARIES

4" INSULATED METAL

WALL PANEL

A-502

F

STUCTURAL FRAME BY MBM

1" / 12"

8" CONCRETE

BACK-UP WALL

2 3/8" CONCRETE FACED

RIGID INSULATION BOARD

C

VAPOR BARRIER

A-500

F

TYPICAL NOTES:

• GIRT SPACING IS SHOWN DIAGRAMATICALLY ONLY,

ACTUAL SPACING WILL BE BY MBM.

• AVB SHALL BE SEALED TO ALL ROOF FABRIC AND ANY

STRUCTURE OR SYSTEMS WHICH PASSES THRU THE

PLAIN OF THE AVB TO FORM A CONTINUOUS AIR VAPOR

BARRIER BETWEEN SPACES, TYP.

B72C-FLOOR1

12' - 0 19/32"

/2

A-502

H

INTERIORINTERIOR

ROOM M

B72-ADDITION

11' - 0 11/16"

C

TERMINATION BAR

APPROVED

SEAL

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

CHECKED BY

DRAWFORM REVISION: 25 AUGUST 2020

DESIGN MANAGER

PROJECT MANAGER

DESIGN DIRECTOR

FIRE PROTECTION

UNCLASSIFIED

UNCLASSIFIED

U N

C

LA

S S

IF

IE

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A

T

LA

N T

IC

NAVFAC DRAWING NO.

SHEET OF

EPROJECT NO.:

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

N A

V A

L S

H

IP

Y A

R D

P

O R

T S

M O

U T

H

N H

FOR COMMANDER NAVFAC

SATISFACTORY TO DATE

ACTIVITY

DRAWN BY

DESIGNER

FAC-YR-NUM

/1

/2

:0

:1

A

M

C

R e v itP ro je c ts

\T O

-0

B

-A R

C H

-V

G ro v e r.

D o n a ld .r v t

A-500

W A

LL

S

E C

TI

O

N S

JRC

DGG

JTL

K

IT

T E

R Y

, M A

IN

E

MMR

LBT

SSR

A -5

P U

B L

IC

W

O R

K S

D E

P A

R T

M E

N T

M

A

IN

E

P O

R T

S M

O U

T H

N A

V A

L S

H

IP

Y A

R D

1710371

C O

N T

R A

C T

N U

M B

E R

:T B

D

P -1

B

R E

S

IL

IE

N

C Y

IM

P

R O

V E

M E

N

TS

NA

SCALE: 3/4" = 1'-0"

A

A-301 D

WALL SECTION

SCALE: 3/4" = 1'-0"

A

A-301 C

WALL SECTION

SCALE: 3/4" = 1'-0"

B

A-301 B

WALL SECTION

SCALE: 3/4" = 1'-0"

B

A-301 A

WALL SECTION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

SCALE: 3/4" = 1'-0"

C

A-300 E

WALL SECTION

SCALE: 1 1/2" = 1'-0"

A

A-500 F

DETAIL - TERMINATION BAR

Sheets
A-500 - WALL SECTIONS

File details come from the government source that posted it. Updated .