31 00 00.00 22_Attachment A_Salt Water Tunnels and Building 72_Historical Drawings.pdf

PDF 36 MB Posted

Attached to
P1112 B72 Resiliency Improvements, Portsmouth Naval Shipyard (PNSY), Kittery, Maine
Solicitation number
N4008526R0005
Issued by

About this file

This is a historical drawing attachment depicting the salt water tunnel systems and Building 72 infrastructure at Portsmouth Naval Shipyard in Kittery, Maine. The document references Yard Plate No. 12, which provides a general layout of salt water tunnels updated through the early 1980s, and includes multiple engineering references spanning from 1912 through 1944. The original salt water intake tunnel was constructed in 1912 per reference drawing 72-12-0140, subsequently converted to a discharge tunnel after a new intake tunnel was constructed from Berth 5 in the 1930s (per drawings 72-33-0311 and 72-33-0317). Building 72's salt water pump room, currently referred to as "Room S," was constructed over the original intake well location, with initial construction documented in 1933 (drawing 72-33-0699) and an easterly addition completed in 1944 (drawing 72-42-0992). Additional engineering references include drawing 72-18-0311 (dated 1918) depicting the new salt water intake tunnel and planned initial construction limits of Building 72, and drawing 72-18-0317 (dated 1918) providing the tunnel profile and construction details. This historical documentation serves as reference material for the P1112 B72 Resiliency Improvements project at Portsmouth Naval Shipyard.

View the file

Other files

File Type Posted
N4008526R0005 Amendment 0010.pdf PDF
Attachment H - Price Proposal Form Revision 3.docx DOCX document
N4008526R0005 Amendment 0009.pdf PDF
Attachment H - Price Proposal Form Revision 2.docx DOCX document
N4008526R0005 Amendment 0008.pdf PDF
01 11 00.00 22_RevAmend08.pdf PDF
GC100A_Milestones and Coordination Requirements_20260528.pdf PDF
00 01 15_RevAmend08.pdf PDF
J and A ML-26-51 P1112 B72 Resiliency Controller Redacted.pdf PDF
098 S-502 Rev. 1 P-1112.pdf PDF
075 S-102 Rev. 1 P-1112.pdf PDF
102 S-506 Rev. 1 P-1112.pdf PDF
A-400 - ENLARGED PLAN -PUMP ROOMS B AND S AND C.pdf PDF
094 S-308 Rev. 1 P-1112.pdf PDF
101 S-505 Rev. 1 P-1112.pdf PDF
A-450 - ENLARGED PLAN DETAILS.pdf PDF
Lifting_Eye_Comp_Cut_Sheet_LIFTMAX-PEP-00100 (050726).pdf PDF
P-1112 Drawing Updates 2026-04-29.pdf PDF
086 S-124 Rev. 1 P-1112.pdf PDF
072 S-001 Rev. 1 P-1112.pdf PDF
N4008526R0005 Amendment 0007.pdf PDF
08 53 00.pdf PDF
N4008526R0005 Amendment 0006.pdf PDF
41 22 13.14.pdf PDF
N4008526R0005 Amendment 0005.pdf PDF
PPI 98 - V-104 Archaeology Area Outlined.pdf PDF
PPI 203 - COMNAVREGMIDLANTINST_11320_11B.pdf PDF
PPI 200 - 32 17 23.pdf PDF
Attachment H - Price Proposal Form Revised.docx DOCX document
PPI 166 - Air Valve Detail.pdf PDF
PPI 137 - 46 30 00 Attachments 1 to 4.pdf PDF
PPI 198 - 26 56 00.pdf PDF
PPIs 181.182.183.208 - Schedule of Special Inspections.pdf PDF
PPI 91 - Sheet 7 of 226 - H-101.pdf PDF
Option 13 - Accessory Structure_REV2.pdf PDF
A-500 - WALL SECTIONS.pdf PDF
N4008526R0005 Amendment 0004.pdf PDF
N4008526R0005 Amendment 0003.pdf PDF
N4008526R0005 Amendment 0002.pdf PDF
P-1112 B72 Resiliency Improvement Site Visit Log.pdf PDF
N4008526R0005 Amendment 0001.pdf PDF
DBIDS 5500 Form.docx DOCX document
Memorandum - Bidding Notes P-1112.pdf PDF
Attachment H - Price Proposal Form.docx DOCX document
P-1112 Specifications.pdf PDF
Attachment D - Past Performance Questionnaire.docx DOCX document
Attachment F - Small Business Participation Commitment Document (SBPCD).docx DOCX document
Attachment G - Small Business Subcontracting Plan (SBSP) Template.docx DOCX document
P-1112 Drawings.pdf PDF
DBIDS 5512 Form.pdf PDF
Show 40 more

Latest 50 of 55 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

roger.roy Callout 1918 Saltwater Intake Tunnel roger.roy Callout 1912 Original Saltwater Tunnel, originally "intake", then in 1918 became "discharge".

roger.roy Text Box

YARD PLATE NO. 12

(UPDATED THROUGH EARLY 1980'S APPROX., DEPICTING GENERAL LAYOUT OF SALT WATER TUNNELS)

Engineer

REFERENCE: 72-12-0140 (DATED 1912)

DEPICTING CONSTRUCTION OF ORIGINAL INTAKE TUNNEL. SUBJECT INTAKE TUNNEL ULTIMATELY BECAME THE "DISCHARGE" TUNNEL AFTER CONSTRUCTION OF NEW INTAKE TUNNEL FROM BERTH 5 IN THE 1930's (REFERENCE DRAWINGS 72-33-0311 AND ..0317). BLDG 72 SALT WATER PUMP ROOM/HOUSE (PRESENTLY REFERED TO AS "ROOM S") WAS SUBSEQUENTLY CONSTRUCTED OVER THE INTAKE WELL SHOWN ON THIS DRAWING (REFER TO DRAWINGS 72-18-0311 AND 72-33-0699.

REFERENCE: 72-18-0311 (DATED 1918)

DEPICTS ORIGINAL CONSTRUCTION OF "NEW" SALT WATER INTAKE TUNNEL, ORIGINAL TUNNEL, AND APPROXIMATE LOCATION OF PLANNED INITIAL CONSTRUCTION LIMIT OF BLDG 72 SALT WATER PUMP ROOM/HOUSE (PRESENTLY REFERED TO AS "ROOM S").

REFERENCE: 72-18-0317 (DATED 1918)

DEPICTS "NEW" SALT WATER INTAKE TUNNEL PROFILE AND DETAILS.

REFERENCE: 72-33-0699 (DATED 1933)

DEPICTING ORIGINAL CONSTRUCTION OF INITIAL PORTION OF THE EXISTING BLDG 72 SALT WATER PUMP ROOM/HOUSE (PRESENTLY REFERED TO AS "ROOM S"). REFER TO DRAWING 72-42-0992 DEPICTING SUBSEQUENT ADDITION TO THE EAST.

REFERENCE: 72-42-0992 (DATED 1944)

DEPICTING ORIGINAL CONSTRUCTION OF EASTERLY ADDITION TO BLDG 72 SALT WATER PUMP ROOM/HOUSE (PRESENTLY REFERED TO AS "ROOM S"). REFER TO DRAWING 72-33-0699 DEPICTING INITIAL ADDITION.

File details come from the government source that posted it. Updated .