5_RR_G111_MENS TOILET.pdf
PDF 96 KB Posted
- Solicitation number
- N4008524R2862
About this file
This document is a detailed room requirements specification for the men's toilets (Room G111) in the P-909 SDVT-2 Operations Support Facility at JEB Little Creek-Fort Story in Norfolk, Virginia. The specifications outline requirements for a men's restroom facility that must be located adjacent to men's locker, showers, laundry and drying rooms, with a minimum ceiling height of 9'-0".
The facility requires 12 water closets, 10 urinals, and 8 lavatories with specific material requirements including CMU walls, HDPE toilet partitions, porcelain tile walls with accent bands, and a 3/16" thick resinous floor coating system. The space includes an 18-foot solid surface counter with integral sinks, comprehensive bathroom accessories (tissue dispensers, mirrors, paper towel dispensers, soap dispensers, hand dryers), and full building systems including HVAC, dedicated exhaust, fire alarm/detection, sprinkler systems, and a public address system. The specifications detail precise requirements for lighting, electrical outlets, and plumbing fixtures, with all finishes meeting Master Painter Institute standards and moisture-resistant materials throughout.
View the file
Other files
Show 40 more
Latest 50 of 52 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P-909 SDVT-2 OPERATIONS SUPPORT FACILITY Work Order Number: 1704761 JEB Little Creek-Fort Story, Norfolk, Virginia
5.0 ROOM REQUIREMENTS
G111 – MEN’S TOILETS
Space Characteristics
FUNCTION: Men’s restroom.
ADJACENCIES: Locate adjacent to the men’s locker, showers, laundry and drying rooms.
SPATIAL REQUIREMENTS:
Ideal Plan Dimensions: See Floor Plans.
Minimum Ceiling Height: 9’-0” Ceiling
ACOUSTICAL REQUIREMENTS:
NUMBER OF OCCUPANTS: 0 PN
OTHER / SPECIAL REQUIREMENTS:
UNIFORMAT DESCRIPTION QTY SIZE SPECIFIC REQUIREMENTS
A1020 GROUND FLOOR SLABS -- Structurally Reinforced Concrete Slab.
C101001 FIXED PARTITIONS
Concrete Masonry Unit (CMU) walls continuous to underside of structural deck above. Provide with bullnose corners and edges.
C101001
FIXED PARTITIONS (PLUMBING
CHASE WALLS)
Cementitious backer board on cold-formed steel studs.
C103001
COMPARTMENTS, CUBICLES &
TOILET PARTITIONS
AR AR
HDPE floor-supported, over-head braced partitions at each water closet/urinal
C103002 TOILET AND BATH ACCESSORIES AR
Double toilet tissue dispensers – jumbo roll size, wall mirrors (match width of counter top - minimum 36” high), full height mirror, semi-recessed paper towel dispenser/disposal, wall mounted soap dispensers at each sink, grab bars, high efficiency electric hand dryer, coat hook on back of each toilet compartment door..
C103004 IDENTIFYING DEVICES
1 per door
Signage on exterior side of room entry door(s). Indicate permanent room name(s) and number
C103008 COUNTERS
2-0”d x 18’-0”l
½” thick solid surface counter with 4” high backsplash and side splashes as required; include integral solid surface sink(s) – SEE D20 Section. Provide high pressure laminate apron on stainless steel brackets underneath counter to conceal exposed plumbing.
C301004 TILE WALL FINISHES SF
12” X
12” min
Porcelain tile on all walls; full height to ceiling, with accent tile band. Provide grouted in stainless steel edge protection strips at all inside and outside corners and where wall tile meets the floor finish. Install with epoxy grout. Provide cementitious backer board at all locations to receive wall tile.
C302007 WALL BASE FINISHES AR 4”h Integral 1” radius, resinous flooring cove base with a stainless steel top cap
C302009 RESINOUS FLOOR COATING SYSTEM SF
3/16” thick standard troweled mortar/quartz broadcast resinous floor coating system
P-909 SDVT-2 OPERATIONS SUPPORT FACILITY Work Order Number: 1704761 JEB Little Creek-Fort Story, Norfolk, Virginia
C303003 GYPSUM BOARD CEILING FINISHES AR AR Moisture resistant gypsum wallboard. Epoxy paint.
C304001 INTERIOR COATINGS / FINISHES
Paint suitable in accordance with Master Painter Institute (MPI) standards for the interior architectural surface being finished.
D201001 WATER CLOSEST (12) Provide floor mounted fixtures.
D201002 URINALS (10) Provide wall-hung fixtures.
D201003 LAVATORIES (8) Provide lavatory faucet for integral countertop lavatory.
D203003 FLOOR DRAINS (2) Provide floor drain. Slope floor finish to drain AR.
D30 HVAC
Provide air conditioning & heating for temperature control.
D304007 EXHAUST SYSTEMS
Provide dedicated, ducted exhaust from bathroom per IBC/ UFC requirements.
D4010 FIRE ALARM / DETECTION SYSTEMS See RFP Part 3; ESR D4010
D4040 SPRINKLER SYSTEMS
Provide wet pipe automatic sprinkler protection providing complete coverage throughout facility. See Part 3; ESR D4040.
D502002 RECEPTACLE OUTLETS Provide cleaning and basin counter receptacles
D502001 LIGHTING EQUIPMENT UFC 3-530-01 3-3.6 Restrooms Type A & B Luminaires
D502002 LIGHTING CONTROLS Per UFC 3-530-01 3-3.6 Restrooms
D503002 PUBLIC ADDRESS SYSTEMS
Provide Public Address system with flush ceiling mounted speakers.
File details come from the government source that posted it. Updated .