This document is a design-build request for proposal for hurricane Florence recovery training and storage facilities at Marine Corps Base Camp Lejeune in North Carolina. The RFP includes requirements for Package 3 which consists of constructing a Log Ops School, II MEF Simulation/Training Center Replacement, and LOGCOM CSP Warehouse Replacement. Specific space characteristics and FF&E requirements are provided for a mother's room to be included in the Log Ops School. The Navy is the contracting agency seeking proposals due by May 12, 2020. Construction must include infrastructure to support specified FF&E and AV equipment to be funded separately as a contract modification.
View the file
Other files
Show 40 more
Latest 50 of 97 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Design-Build Request for Proposal RTA Hurricane Florence Recovery Training and Storage Facilities 3 March 202012 May 2020 Marine Corps Base Camp Lejeune, North Carolina Rev 01
PART 3 - CHAPTER 5 - P1512F JOINT RECEPTION CENTER - Page 22
P1512F- LOG OPS SCHOOL
Mother’s Room
Space Characteristics
Function/Adjacencies: This small private room is for new mothers to support at home baby-feeding activities while at work. It features a comfortable armchair with retractable tablet arm for a breast pump, electric outlet for power, small refrigerator, small sink in base cabinet with drawers. This room would be a part of the central administrative area or near that area and accessed by a public corridor.This room can be part of the H&S area, the PAC area, or in separate area between departments in grouping with other common areas as long as it accessible to the building at large.
Special Dimensions:
Ideal Plan Dimensions:
Minimum Ceiling Height: 8’-0”
Acoustics:
Refer to ESR C10 for partition STC rating Access: Off corridor system
Number of Occupants: 1
Other/Special Requirements:
FF&E and A/V Information for Coordination:
FF&E and AV Equipment will be funded separately as a modification to the construction contract. Infrastructure to support all FF&E and AV must be included in the construction contract. Contractor’s Interior Designer must validate and determine FF&E requirements based on in-depth interviews with Activity at Concept Design workshop (CDW). Space will accommodate, at a minimum, the following FF&E and A/V:
Uniformat Section
Description Qty Size Specific Requirements
A1030 Slab on Grade SF SF
C1010 Fixed Partitions SF Gypsum wallboard (GWB) on steel studs to underside of floor/roof deck (or underside of finished ceiling). Include sound insulation.
C1020 Interior Wood Doors 1 3’ x 7’
Solid core, flush door with stain finish, along with hollow metal steel frame, factory primed, field painted. Provide vision panels; integral to door frame (approx. 6” x 18”).
C1020 Interior Door Hardware Hinges and stop provide privacy lockset hardware.
C1030 Identifying Devices Signage on exterior of room entry door(s): Indicate the room name for the space being entered with an “Occupied” slider bar.
C1030 Counters
Length of counter to match length of sink base cabinet and undercounter refrigerator space
½” thick solid surface counter with full height or 4” high backsplash and 4” high side splashes
Design-Build Request for Proposal RTA Hurricane Florence Recovery Training and Storage Facilities 3 March 202012 May 2020 Marine Corps Base Camp Lejeune, North Carolina Rev 01
PART 3 - CHAPTER 5 - P1512F JOINT RECEPTION CENTER - Page 23
Mother’s Room
Space Characteristics
Function/Adjacencies: This small private room is for new mothers to support at home baby-feeding activities while at work. It features a comfortable armchair with retractable tablet arm for a breast pump, electric outlet for power, small refrigerator, small sink in base cabinet with drawers. This room would be a part of the central administrative area or near that area and accessed by a public corridor.This room can be part of the H&S area, the PAC area, or in separate area between departments in grouping with other common areas as long as it accessible to the building at large.
Special Dimensions:
Ideal Plan Dimensions:
Minimum Ceiling Height: 8’-0”
Acoustics:
Refer to ESR C10 for partition STC rating Access: Off corridor system
Number of Occupants: 1
Other/Special Requirements:
FF&E and A/V Information for Coordination:
FF&E and AV Equipment will be funded separately as a modification to the construction contract. Infrastructure to support all FF&E and AV must be included in the construction contract. Contractor’s Interior Designer must validate and determine FF&E requirements based on in-depth interviews with Activity at Concept Design workshop (CDW). Space will accommodate, at a minimum, the following FF&E and A/V:
Uniformat Section
Description Qty Size Specific Requirements
C1030 Cabinets
Base cabinets under sink counter and space to place an undercounter refrigerator. Set of wall cabinets the full length of the sink counter sink counter. Provide minimum 42” ABA accessible sink base cabinet.
C3010 Gypsum Wallboard
Finishes AR AR Primed and painted gypsum wallboard
C3010 Corner and Wall Guards AR
1-1/2” flange, Full-
Height
Surface-mounted, color-matched, through-color, recycled, extruded PETG corner guards on all outside corners of gypsum wallboard partitions.
C3020 Wall Base Finishes LF 4” high Rubber cove base in 120’ coils
C3030 Acoustical Ceiling Tiles
& Panels AR 24 x 24 Acoustical Ceiling Tile
C3030 Suspension Systems AR AR 9/16” suspended ceiling system
C3040 Interior Coatings AR AR Paint suitable in accordance with Master Painter Institute (MPI) standards for the interior architectural surface being finished.
D5020 Lighting and Branch
Wiring Provide dimmable LED direct/indirect lighting.
File details come from the government source that posted it. Updated .