FA520517R0004_Atch9_Mfr's_Cut_Sheet_Catalog_Info.pdf

PDF 16 MB Posted

Attached to
Improve Military Family Housing (IMFH) Phase III, A/C and Weatherization, Misawa Air Base, Japan
Solicitation number
FA5205-17-R-0004
Issued by

About this file

FA520517R0004_Atch9_Mfr's Cut Sheet Catalog Info

View the file

Other files

File Type Posted
FA520517R00040005_Amendment.pdf PDF
FA520517R00040005_Atch3.pdf PDF
FA520517R00040005_Atch1.pdf PDF
FA520517R00040005_Atch4.pdf PDF
FA520517R00040005_Atch7.pdf PDF
FA520517R00040005_Atch6.pdf PDF
FA520517R00040005_Atch2.pdf PDF
FA520517R00040005_Atch5.pdf PDF
FA520517R00040004_Atch4.pdf PDF
FA520517R00040004_Amendment.pdf PDF
FA520517R00040004_Atch3-4.pdf PDF
FA520517R00040004_Atch3-3.pdf PDF
FA520517R00040004_Atch5.pdf PDF
FA520517R00040004_Atch1.pdf PDF
FA520517R00040004_Atch2.pdf PDF
FA520517R00040004_Atch3-5.pdf PDF
FA520517R00040004_Atch3-2.pdf PDF
FA520517R00040004_Atch3-1.pdf PDF
FA520517R00040003_Atch1.pdf PDF
FA520517R00040003_Atch2.pdf PDF
FA520517R00040003_Amendment.pdf PDF
FA520517R00040002_Amendment.pdf PDF
FA520517R00040002_Atch.pdf PDF
FA520517R00040001_Atch2_Revised_Specification_Section.pdf PDF
FA520517R00040001_Amendment.pdf PDF
FA520517R00040001_Atch4_Revised_Solicitation_Page.pdf PDF
FA520517R00040001_Atch1_Addendum_No._1.pdf PDF
FA520517R00040001_Atch3_Revised_Drawings.pdf PDF
FA520517R0004_PreProposal_Conference_Minutes_&_Record_of_Site_Visit.pdf PDF
FA520517R0004_Atch2_Drawings_8_Electrical.pdf PDF
FA520517R0004_Atch2_Drawings_6_Plumbing.pdf PDF
FA520517R0004_Atch10_Asbestos_Sampling_and_Analysis.pdf PDF
FA520517R0004_Atch2_Drawings_3_Structural.pdf PDF
FA520517R0004_Atch2_Drawings_2_Hazmat.pdf PDF
FA520517R0004_Atch2_Drawings_5_Mechanical.pdf PDF
FA520517R0004_Atch4_PPQ_Cvr_Ltr.pdf PDF
FA520517R0004_Solicitation.pdf PDF
FA520517R0004_Atch8_Acceptable_JPN_Product_Substitutes.pdf PDF
FA520517R0004_Atch2_Drawings_7_Controls.pdf PDF
FA520517R0004_Atch2_Drawings_4_Architectural.pdf PDF
FA520517R0004_Atch2_Drawings_1_General.pdf PDF
FA520517R0004_Atch3_Other_Contract_Requirements.pdf PDF
FA520517R0004_Atch1_Specifications.pdf PDF
FA520517R0004_Atch6_Construction_Timeline.pdf PDF
FA520517R0004_Atch5_PPQ.pdf PDF
FA520517R0004_Atch7_Schedule_of_Material_Submittals.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Atch. 9 to RFP No. FA520517R0004 Dated 27 Feb 17

Core

Aggregation

Brocade

MLX

Large Campus

Brocade FCX Series

Small/Medium-size Campus

Brocade

MLX

Access

FastIron

SX

Brocade FastIron SX

Brocade

ICX 6610

Brocade FastIron SX

Remote Location

Brocade

MLX

Brocade Network Advisor Brocade FastIron SX

Access

Brocade

ICX 6450

MCT

Brocade FastIron SX

MCT Brocade

ICX 6610

Brocade

ICX 6430

Brocade

ICX 6450

Brocade HyperEdge Mixed Stack

Data Center Access

Data Center Aggregation

40 GbE

40 GbE Data Center Core

Brocade

ICX

Brocade

ICX

Brocade

ICX

Brocade

ICX

Brocade

ICX

Brocade ICX1 GbE

Servers

1 GbE

10 GbE

40 GbE

Brocade

ICX 6650

Brocade

ICX 6650

is;

LINE - HIDE

Lineset Cover System

A complete system for completing the job

& BEAUTIFY

PROTECT

& BEAUTIFY

PROTECT

TM

Dimensions (in inches) Weight Product A B C D E (ounces)

LINE - HIDE Lineset Cover System

PRODUCT INFORMATION & SPECIFICATIONS

Split Line Tube (PVC)

CD-60 2-1/4 2-5/16 78-3/4 38.8

CD-75 2-15/16 2-7/16 78-3/4 44.1

CD-100 3-7/8 2-11/16 78-3/4 64.2

CD-140 5-7/16 3-1/16 78-3/4 73.4

Split Line Tube (ASA)

DD-60 2-1/4 2-5/16 78-3/4 38.8

DD-75 2-15/16 2-7/16 78-3/4 44.1

DD-100 3-7/8 2-11/16 78-3/4 64.2

DD-140 5-7/16 3-1/16 78-3/4 73.4

Wall Cover/Inlet

NW-60 2-9/16 2-9/16 7-7/8 3-1/16 3-3/16 6.3

NW-75 3-1/4 2-11/16 8-1/4 3-11/16 3-1/4 7.9

NW-100 4-3/16 2-15/16 9-1/8 4-11/16 3-3/4 10.6

NW-140 5-3/4 3-3/8 11-1/4 6-1/4 4-1/8 16.2

Simple Wall Cover

NY-60 2-9/16 2-9/16 7-7/8 3-1/16 3-3/16 6.3

NY-75 3-1/4 2-11/16 8-1/4 3-11/16 3-1/4 7.9

NY-100 4-3/16 2-15/16 9-1/8 4-11/16 3-3/4 10.6

NY-140 5-3/4 3-3/8 11-1/4 6-1/4 4-1/8 16.2

Socket/Coupling joins two pieces of tubing

NS-60 2-9/16 2-9/16 3-1/8 2.5

NS-75 3-1/4 2-11/16 3-1/8 2.8

NS-100 4-3/16 2-15/16 3-1/8 3.5

NS-140 5-3/4 3-3/8 3-1/8 4.8

End Socket (Can be cut to accommodate various lineset combinations)

NR-60 2-1/16 1-3/16 3-7/8 2-9/16 2-9/16 2.3

NR-75 2-1/16 1-3/16 3-7/8 3-1/4 2-11/16 2.8

NR-100 2-1/16 1-3/16 4-1/2 4-3/16 2-15/16 4.1

NR-140 2-1/16 1-3/16 5-5/8 5-3/4 3-3/8 7.1

Universal Elbow (Horizontal) adjustable 45° to 90°

NX-75 3-1/4 2-11/16 6 7.6

NX-100 4-3/16 2-15/16 7-5/8 11.6

NX-140 5-3/4 3-3/8 9-3/4 17.6

90° Elbow (Horizontal)

NE-60 2-9/16 2-9/16 4-11/16 4.8

NE-75 3-1/4 2-11/16 5-9/16 6.3

NE-100 4-3/16 2-15/16 6-5/16 8.5

NE-140 5-3/4 3-3/8 7-7/8 13.0

Universal Elbow (Vertical) adjustable 45° to 90°

NZ-60 2-9/16 2-9/16 4-5/8 5.3

NZ-75 3-3/8 2-11/16 4-13/16 6.0

Reversible for inside or outside corner

90° Elbow (Vertical)

NC-60 2-9/16 2-9/16 4-3/4 5.3

NC-75 3-1/4 2-11/16 4-7/8 6.0

NC-100 4-3/16 2-15/16 5-5/16 8.5

NC-140 5-3/4 3-3/8 5-7/8 11.6

Reversible for inside or outside corner

45° Elbow (Horizontal)

NM-60 2-9/16 2-9/16 2-11/16 3.4

NM-75 3-1/4 2-11/16 2-15/16 3.9

NM-100 4-3/16 2-15/16 3-5/16 5.3

NM-140 5-3/4 3-3/8 4-3/16 8.5

45° Elbow (Vertical)

NU-60 2-9/16 2-9/16 2-5/8 3.4

NU-75 3-1/4 2-11/16 2-13/16 4.2

NU-100 4-3/16 2-15/16 3-1/4 5.3

NU-140 5-3/4 3-3/8 3-11/16 8.3

Reversible for inside or outside corner

Equipment specifications and data herein are subject to change without noti

Variant Socket/Reducer (Used to change size of tube)

NJ-60/75 2 3/4 2-11/16 3-1/8 3-1/4 2-11/16 2.8

NJ-75/100 3 3/8 2-13/16 3-1/8 4-3/16 2-15/16 3.7

NJ-100/140 4-1/2 3-1/16 3-1/8 5-3/4 3-3/8 4.8

Wall Entry Fitting

NK-60 4-5/16 4-5/16 5/8 2.4

NK-75 4-15/16 4-1/2 5/8 2.7

NK-100 6-7/8 5-11/16 5/8 4.5

NK-140 8-11/16 7-1/16 5/8 6.7

T-Joint

NT-75 3-1/4 2-11/16 4-3/4 6-5/16 1 8.0

NT-100 4-3/16 2-15/16 6-5/16 8-7/16 1-3/8 10.6

NT-140 5-3/4 3-3/8 7-7/8 10 1-3/8 16.4

NT-75 suppplied with 2 Reducing Adaptors (75>60)

NT-100 suppplied with 4 Reducing Adaptors: 2 - (100>60) & 2 - (100>75)

NT-140 suppplied with 2 Reducing Adaptors (140>100)

Corner Cap/Soffit Entry Fitting

NA-60 2-5/8 2-9/16 2-5/8 4-1/8 4-5/16 3.2

NA-75 3-5/16 2-3/4 2-5/8 4-7/8 4-15/16 3.5

NA-100 4-5/16 3 2-5/8 5-7/8 5-1/2 4.6

NA-140 5-13/16 3-3/8 2-5/8 7-7/16 6-1/8 5.5

Flexible Joint (Polypropylene material) available in nominal 2-foot and 3-foot lengths

NF-60 2-5/16 2-3/8 2-3/8 21-5/8 4.1

NF-60M 2-5/16 2-3/8 2-3/8 39-3/8 10.2

NF-75 3 2-1/2 2-3/8 21-5/8 4.8

NF-75M 3 2-1/2 2-3/8 39-3/8 12.3

NF-100 4 2-3/4 2-15/16 31-1/2 12.7

NF-140 5-1/2 3-1/8 3-1/8 39-3/8 20.8

Saddle Band

NV-S 11-13/16 0.0

NV-L 14-3/16 0.0

NV-L for 100 and 140; NV-S for 60 and 75

Base snaps into track in line tube to hold lineset in place.

LINE - HIDE

Lineset Cover System

Put a professional finish on air conditioning installation with an easy-to-install modular system that beautifies exteriors and protects linesets, drainlines, and wiring.

• Available in four sizes — 21/4'', 3'', 4'', and 6'' tubes.

• Snap-on covers and a full selection of couplings, elbows, T-joints, caps, and more for any application, complex or simple.

• High-quality PVC with UV inhibitors for outdoor service in all weather conditions.

• Can be painted with most house paints to match exterior decors.

• Not just for HVAC. Hide any exterior cabling, piping, or wiring.

• Use it indoors, too! Meets UL94v-0 for interior applications.

TM

3400 Lawrenceville Suwanee Rd. • Suwanee, GA 30024 phone 678/376-2900 • fax 678/376-2890 • E-mail line-hide@hvac.mea.com • www.line-hide.com

© 2005 Mitsubishi Electric

LBRCA11 06/05 10M

Limited Warranty

Mitsubishi Electric & Electronics USA, Inc. warrants to the original consumer purchaser of a Line-Hide product that it will replace any part which fails due to a manufacturing defect within one year from the date of original purchase.

This warranty covers only replacement of the product itself with the owner paying all other costs, including labor, mileage, and transportation.

To make a warranty claim, contact your installer, or contact Mitsubishi Electric & Electronics USA, Inc., at 678/376-2900, fax 678/376-2890. You must present proof of purchase to make a claim.

WHAT IS NOT COVERED:

Conditions and damages resulting from improper installation, delivery, or maintenance.

Misuse, abuse, accidents, or unreasonable use of product.

The cost of service to correct installation errors.

Consequential or incidental damages sustained by any person as a result of any breach of this warranty.

THIS WARRANTY IS NON-TRANSFERABLE AND IS THE ONLY WARRANTY

PROVIDED. ALL OTHER WARRANTIES, INCLUDING THE IMPLIED WARRANTIES

OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE

EXPRESSLY DISCLAIMED.

THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. HOWEVER, YOU MAY

HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE. SOME STATES

DO NOT ALLOW LIMITATION ON IMPLIED WARRANTIES OR EXCLUSION OF

CONSEQUENTIAL DAMAGES; THEREFORE THESE RESTRICTIONS MAY NOT

APPLY TO YOU.

Line-Hide Specifications:

Material Weather resistant, UV stabilized, ASA/PVC/ABS/Poly/PE

Temperature Range PVC: -4°F to 140°F ASA: -4°F to 194°F

Fire Rating PVC/ABS meets UL94v-0, Poly/PE meets UL94HB

Weather Resistance Pass 2,000 hour test to JIS DO 205 Standard

Standard Color Ivory

Mounting Molded in mounting screw locations

Assembly Screws Stainless Steel www.elstermesstechnik.com

M 120 Multi-jet meter Dry-dial meter with metrological precision and transparency

Multi-jet dry-dial meter for cold water Nominal flow rate Qn 1.5 to 15 m3/h/ Q3 2.5 to 25 m3/h EEC approval metrological class B·H MID-type examination certificate R160 Good readability even at extreme operational conditions Hermatically sealed counter Antimagnetic shield (optional) ELSTER conText® inscription system

Cold water up to 30 °C

D 98 6.131.05

EEC approval

Cold water up to 30 °C

DE-08-MI0001-PTB020

MID-type examination certificate

MTR

Flange

MTR

H2

H1

L1

D1

B1

H2

H1

L1

B1 132 x

H2

B1

B2

L1

D1

MTR-S

Flow rate in m3/h

Pr es su re lo ss in b ar

Qn 1.5 2.5 3.5 6 10 15

ELSTER Messtechnik GmbH Otto-Hahn-Strasse 25 68623 Lampertheim Germany

T +49 (0) 62 06 933 0 F +49 (0) 62 06 933 100 E messtechnik@de.elster.com www.elstermesstechnik.com

M120_D_01.03e / 10.10 Changes without notice

Copyright ELSTER Messtechnik GmbH

Reed Disc with tamper detection Type Reedswitch potted, protection IP 68 Contact load max. 24 V DC, 50 mA Resistance 100 Ohm Cable 3 x 0.14 mm2

Ø 3.3 mm Pulse contact brown – white Tamper contact green – white Cable length 3 m Ordering number 100 litres/1 pulse 0000998 1000 litres/1 pulse 0000999 p 0.

ba r a t Q m ax

/Q p 0.

ba r a t Q n/ Q

Multi-jet meter M120 MTR MTR-S Meter size / Nominal flow rate Qn m3/h 1.5 2.5 3.5 6 10 15 15 1.5 2.5 6 10 Q3 m3/h 2.5 4 6.3 10 16 25 25 2.5 4 10 16 Nominal size DN mm 15 20 25 25 40 50 50 20 20 25 40 DN inches 1/2 3/4 1 1 1 1/2 2 2 3/4 3/4 1 1 1/2

Ordering number EEC approval** Standard Initial certification B·H 0755788 0755826 0755850 0755869 0755885 0755893 0755915 0755958 0755966 0755982 0756008 Pulse-preparation 100 litres/1 pulse R 0757837 R 0757853 0757888 0757896 0757918 0757942 0757977 0757993 0758027 Pulse-preparation 1000 litres/1 pulse R 0758116 R 0758132 0758159 0758167 0758175 0758221 0758248 0758272 0758302 Optional Initial certification C·H 0001113 0001454 0001904 0001905 0001906 — — — — — —

Dimensions D1 Meter conn. thread ISO 228/1 inches G 3/4 B G 1 B G 1 1/4 B G 1 1/4 B G 2 B G 2 1/2 B Flange G 1 B G 1 B G 1 1/4 B G 2 B Conn. pipe thread ISO 7/1 inches R 1/2 R 3/4 R 1 R 1 R 1 1/2 R 2 — R 3/4 R 3/4 R 1 R 1 1/2 L1 Meter length mm 165 190 260 260 300 270 270 105 105 150 200 Connector length mm 50 50 60 60 70 60 — 50 50 60 70 B1 Width mm 100 100 100 100 100 100 100 100 100 100 100 B2 Distance mm — — — — — — 80 80 94 120 H1 Centerline height mm 31 31 43 43 46 46 68 — — — — H2 Overall height mm 115 115 130 130 153 153 160 135 135 151 195 Weight kg 1.5 1.6 2.5 2.5 3.7 4.5 8.5 1,8 1,8 2.6 5.5

Performance characteristics Maximum flow rate Qmax/Q3 m3/h 3/3.1 5/5 7/7.9 12/12.5 20/20 30/31.2 30/31.2 3/3.1 5/5 12/12.5 20/20 Transitional flow rate Qt/Q2* l/h 22.5/25 37.5/32 52.5/50 90/80 150/150 300/300 300/300 22.5/25 37.5/32 90/80 150/150 Minimum flow rate QminQ1* l/h 15/15 22/20 30/30 50/50 80/100 250/200 250/200 15/15 22/20 50/50 80/80 Starting flow l/h 5.5 10 12 18 25 45 45 10 15 30 50 Measuring range Q3/Q1 H R160 R160 R160 R160 R160 R100 R100 R160 R160 R160 R160

Continuous load approx. 1.6 x Qn l/h 2 500 4 000 5 600 10 000 16 000 25 000 25 000 2 500 4 000 10 000 16 000 Temperature Tmax °C 30 30 30 30 30 30 30 30 30 30 30 Pressure rating PN bar 16 16 16 16 16 16 16 16 16 16 16 Flow capacity at 1 bar pressure loss m3/h 3.3 5.5 7.2 12.8 22 32 32 4.0 6.7 12.8 22

R: on request

* typical performance characteristics, exceeds the demands of the metrological class B and C/R100 and R160; ** MID type examination on request

Q3 2.5 4 6.3 10 16 25 www.sensus.com

Application

When you are searching for a compact water meter with a good cost-performance ratio the 120 with its many advantages is the perfect solution.

This dry dial single jet meter is a water meter for billing purposes with an integrated AMR interface for easy and versatile read out.

Not only its outstanding metrology argues for this tamper-proof meter but also its strength and robustness.

Main Characteristics

DN 15 and 20

Magnetic transmission

Suitable up to 40 °C as a cold water meter

Suitable up to 90 °C as a warm water meter

Insensitive to upstream disruptive elements

355° swiveling register

High resistance to water impurities

AMR pre-equipped for pulse or radio interface

Available with non return valve

Dry dial single jet water meter

LD1900INT Page 2

Protected against misuse

A special safety device offers resistance against mechanical forces.

Protection against magnetic manipulation is guaranteedthrough a special shield.

An annular shield protects the meter against manipulation with a hot needle*

High quality components

Foreign matters present in water can be filtered by the tubular strainer. The smallest particles can go trough the meter without damage.

The 120 water meter keeps its metrological accuracy for many years of operation, even in very difficult working conditions.

Metrology

The optimized hydraulic and low friction gear train assures high dimension stability; therefore metrological performance that almost reaches class C can be expected.

* optional

HRI Interface

The 120 can be equipped with all the Sensus advanced module range.

With an accuracy of less than 1ppm (i.e. deviation less than 1 liter with more than 1.000 m³ registered) the interface remains reliable in any circumstance.

LD1900INT Page 3

Typical Accuracy Curve

Typical Head Loss Curve

Approvals

Communication

The 120 can be equipped with all the Sensus advanced module range.

Different modules with integrated functions are available:

1. HRI Pulse Unit (A-version) The liter pointer activates the HRI allowing a basic resolution of one liter per pulse. The output pulse value can be factory set using the divisor D (e.g. D = 100 means 1 pulse per 100 liters). The possible pulse output D values are (amongst others):

1 / 10 / 100 / 1000 / 2.5 / 25 / 250

2. HRI Data Unit (B-version) The HRI Data Unit is a data interface which provides an accurate meter reading as well as the serial or customer ID. The pulse output as described above is also included. The HRI Data Unit can be connected to a M-Bus network for remote read or a MiniPad for mobile inductive read (MiniBus), both in accordance with the IEC

870. HRI Data Unit with Sensus protocol can also be supplied on request.

3. Sensus((S))cout Radio Unit This integrated module in conjunction with the reliable HRI sensing technology provides the option of an easy and quick remote reading capability through a mobile or fixed radio network.

Legibility

The display on 8 drums (5 for m³, 3 for litres) and 1 pointer ensures perfect readability. The lowest resolution is 0.05 litres. The dial has a central disc whose rotation indicates the passage of water.

This indicator can be used to reveal a downstream leak.

The 120 water meter operates in horizontal position and its dry dial can rotate up to 355°. The dial can therefore be easily read under all conditions of use.

As an option (standard for ?) the meter can be supplied with a cupper-glass register, making it perfectly water-tight (IP 68).

EEC directive 75/33/EEC

Qn 1.0 / 1.5 / 2.5

Class B (H) / A other positions

Qn 1.0 / 1.5 / 2.5

Class B (H) / A other positions

D 78

6.131.107

D 86

6.331.78

EEC directive 79/839/EEC

Qn 1.

Qn 1.

5 Qn 2.

LD1900INT Page 4

Technical characteristics

Dimensions

Metrological characteristics – EEC Directive 75/33

Nominal Size DN mm 15 20

Nominal flowrate Qn m³/h 1.0 1.5 1.5 2.5

Metrological class B(H) / A

Maximum flowrate Qmax m³/h 2,0 3,0 3,0 5,0

Minimum flowrate (tolerance ± 5%) Qmin l/h 20 30 30 50

Transitional flowrate (tolerance ± 2%) Qt l/h 80 120 120 200

Sizes and weight

Nominal Size DN mm 15 20* 20**

Length L mm 110 115 130 130

Width D mm 73 73 73 73

Width (with assembled HRI) D’ mm 94 94 94 94

Total height H mm 105 105 100 100

Total height (with assembled HRI) H’ mm 116 116 110 110

Height to pipe axis h mm 23 23 17.5 17.5

Piping dimension inch ½" ½" ½" ¾" ¾"

Tail Diameter G¾"B G¾"B G7/8"x ¾" G¾"B G1" G1"

Piece mm 26.44 26.44 26.44 33.25 33.25

Thread Pitch 1.814 1.814 1.814 1.814

Weight g 481 544 509 531 571 563

Operational characteristics (Manufacturers data; non-contractual)

Nominal Size DN mm 15 20* 20**

Starting flowrate l/h 7 7 10

Minimum flowrate l/h 20 25 50

Transitional flowrate l/h 60 80 200

Maximum registration m³ 105

Lowest resolution l 0.05

Pressure loss at Qmax bar 0.9

Pressure class PN bar 10

*Qn 1,5 **Qn 2,5

*Qn1,5 **Qn 2,5

Certified according to ISO 9001 Quality Management System Quality Austria Reg.no. 3496/0 www.mcquay.com

PSYCHROMETRIC ANALYZER Version 6.8 by McQuay International

APPENDIX D

ELECTRICAL

APPENDIX D - ELECTRICAL

Page Intentionally Left Blank www.distech-controls.com 1/4

Datasheet

EC-BOS-6AX

Ideal for smaller facilities, remote sites, and for distributing control and monitoring throughout large facilities.

remote I/O and stand-alone controllers.

Serves data and rich graphical displays to a standard web browser via an Ethernet LAN or remotely over the Internet.

In larger facilities, multi-building applications and large-scale control system integrations, the EC-NetAX Supervisor software can be used to aggregate information (real-time data, history, alarms, etc.) from large numbers of EC-BOSAX

Using EC-NetAX Supervisor, you can manage global control functions, support data passing over multiple networks, connect to enterprise level software applications, and host multiple, simultaneous client workstations connected over the local network.

The EC-BOS-6AX is a compact, embedded controller/server platform. It combines integrated control, supervision, data logging, alarming, scheduling and network management functions with Internet connectivity and web serving capabilities in a small, compact platform. The EC-BOS-6AX makes it possible to control and manage external devices over the Internet and present real time information to users in web-based graphical views.

Also offered is the EC-BOS-6AX UUKL model, which is a UL 864 UUKL Listed Smoke Control Equipment for application in a Distech Controls UUKL smoke control system.

Both models are part of the EC-NetAX suite of Java-based controller/ server products, software applications and tools, which are designed to integrate a variety of devices and

AX products are powered by the NiagaraAX Framework®, the industry’s systems and devices into a seamless system. EC-NetAX supports a wide range of protocols including LONWORKS®, BACnet® and Internet standards. EC-NetAX also includes integrated network management tools to support the design, networks.

Applications

Overview eat res ene ts

Supports open and legacy protocols Web User interface (optional) serves rich graphical presentations for easier and more user-friendly control of control system integrations Integral energy management routines Run stand-alone control, energy management and integration applications Supports two optional communications boards Small compact design is easy to install and supports multiple power options Optional I/O Modules Data Recovery Services prevents data loss during power interruptions Includes oBIX client/server and Niagara Network (Fox) client/server drivers BTL listed when BACnet driver is used. Complies with B-BC (BACnet Building Controller)

2/4 EC-BOS-6AX

EC-NetAX I/O Modules1

EC-NetAX IO-16:

8 universal inputs 4 form A Relay outputs 4 Analog outputs (0-10VDC) Up to four (4) IO-16 can be connected to the

EC-BOS-6AX

EC- NetAX IO-34:

16 universal inputs 10 form A Relay outputs 8 Analog outputs (0-10VDC) Maximum one (1) IO-34 can be connected to the EC-BOS-6AX

In addition to the IO-34, up to two (2) IO-16 can also be connected to the EC-BOS-6AX

Distech Controls I/O Modules2

ECC-301:

8 universal inputs 8 triac outputs

ECC-401:

12 universal inputs 12 triac outputs

ECC-520:

16 universal inputs

Other Products (Hardware)

EC-NPB-LON 78Kbps FTT-10A LON adapter

EC-NPB-2X-485 Dual port RS-485 option card

EC-NPB-232 Single port RS-232 option card

EC-NPB-GPRS-W GPRS Modem kit – includes modem card and SIM

EC-WPM-US 90-240VAC, 50/60Hz Wall adapter U.S. plug type

EC-WPM-EU 90-240VAC, 50/60Hz Wall adapter European/Asian plug type

EC-WPM-UK 90-240VAC, 50/60Hz Wall adapter U.K. plug type

EC-NPB-PWR 24V AC/DC, 50/60Hz Power Supply Module. DIN rail mountable

EC-NPB-PWR-UN 90-263VAC/15VDC, 50/60Hz Universal Power Supply Module. DIN rail mountable

Other Products (Software)

EC-DR-LONAX LONWORKS driver

EC-DR-MSTPAX Driver for MS/TP BACnet communications over RS-232 or RS-485 port

EC-DR-BACnetAX BACnet IP Client over Ethernet

EC-NPM-256 Memory Upgrade option. Upgrades JAVA Heap from 48MB up to 96MB

EC-UI-SP-AX Web User Interface add-on

EC-WPAX-WEB Embedded EC-NetAX Pro (requires EC-UI-SP-AX)

For more information on these or other Distech Controls products please refer to our web site.

1. For more information and details please refer to the EC-NetAX I/O Modules datasheet.

2. For more information please refer to the Remote I/O datasheet.

Recommended Peripherals

3/4EC-BOS-6AX

Product Speci cations1 2

Platform3 27BChassis

Processor IBM PowerPC 440 524MHz processor Construction Plastic, din rail or screw mount chassis, plastic cover

Memory 256MB DDR RAM, 48MB Java Heap and -Cooling Internal air convection

128MB Serial Flash -Dimensions 16.0cm (6.3”) W x 12.2cm (4.8”) H (including

Backup Capability Data recovery services with SRAM connectors) x 6.2cm (2.4”) D

Real-Time Clock -Weight 0.708 Kg (1 lb 9 oz)

Communications Environment

Methods: Operating Temp. 0°C to 60°C (32°F to 140°F)

- 2 Ethernet Ports – 10/100Mbps (RJ-45 connectors) Storage Temp. 0°C to 70°C (32°F to 158°F)

- 1 RS-232 Port (9-pin D-shell connector) Relative Humidity 5% to 95%, non-condensing

- 1 RS-485 port Agency Listings

- 1 One 20-Pin Euro-DIN Connector (for I/O and Power modules) UL UL916

- 2 communication card option slots C-UL listed to Canadian Standards Association

Operating Systems (CSA) C22.2 No. 205-M1983 “Signal Equipment”

Types:

UL 864 UL 864, 9th Edition, UUKL Listed Smoke Control

Equipment (EC-BOS-6AX UUKL model only)1 -QNX RTOS

-IBM J9 JVM Java Virtual Machine California State Fire Marshal Listing

CSFM: 7300-2187:0100 (EC-BOS-6AX UUKL model only)1 -Oracle Hotspot Java 5 VM

-EC-NetAX 3.6 or later CE For details, refer to EC-BOS-6AX Hardware

Installation Guide

Wiring Instructions

FCC Part 15 Class A

RoHS RoHS compliant

1. AX UUKL model, refer to the Distech Controls UUKL Smoke Control Design Guide (05DI-UGULDES-10).

2.

3. Requires NiagaraAX version 3.2 or higher.

4/4

LONWORKS

05DI-DSRCXXX-20

05DI-DSBS6AX-35

EC-BOS-6AX

Typical Architecture

GE

Industrial Solutions

A-Series* II Panelboard AMP1 Integrated Power and Energy

Fact Sheet Overview

The AMP1 Power & Energy Meter provides a cost-effective integrated solution for A-Series* II panelboard power monitoring and submetering applications. With exceptional performance, the AMP1 monitors key electrical parameters of the main power coming into the panelboard. This informa-tion can then be transmitted to a building automation system (BAS), or similar system, to analyze usage and identify potential cost saving measures. Offering ANSI 12.20 0.5% accuracy, the revenue grade AMP1 meter can be used for tenant billing and cost allocation.

The A-Series* II panelboard comes with the AMP1 meter completely integrated, including current transformers, eliminating the need for any field installation or modifications.

This integrated solutions helps you to meet the Measurement and Verification points required by the LEED and GREEN building design. Optional data logging capability protects and stores up to 60-days worth of data internally.

The AMP1 meter can be factory integrated in any of the following A-Series* II panelboards up to 800 amperes: AQ, AE, AS, AQP, AEP, and ADP. Main Lug and Main Breaker configura-tions (THQB, THHQB, TEY, TEYF, TEYD, TEYH, TEYL, SE, SF, SG, SK) are also available. The Pulse, Modbus®, and BACnet output models offer added flexibility for system integration.

Benefits:

Analysis of potential cost saving actions Verify energy bills Identify wasteful practices & decrease unnecessary usage Fairly and accurately allocate energy costs to users Produce an energy profile Secure the optimum utility rate structure

Features:

Solutions up to 800A Revenue Grade, ANSI 12.20 0.5% accuracy Monitors voltage, amperage, power, and energy Backlit LCD Display Data logging option to ensure data is still preserved locally Communicates via Modbus® RTU or BACnet – Versatile and widely used protocols.

User-enabled password protection UL-67 approved 5-Year warranty Earn points towards LEED Certification

Applications Energy monitoring in building automation systems Renewable energy Energy management Commercial submetering Industrial monitoring Cost allocation

GE

Industrial Solutions 41 Woodford Avenue Plainville, CT 06062 www.geindustrial.com

© 2013 General Electric Company

* Trademark of General Electric Company All other brands or names are property of their respective holders.

Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. DEQ-592 (08/13)

AMP1 Technical Specifications

Inputs:

Control Power, AC

50/60 Hz; 5VA max.; 90V min.;

UL Maximums: 600V L-L (347V L-N ); CE Maximums:

300V L-N (520V L-L )

Control Power, DC

3W max.; UL and CE: 125 to 300VDC (external DC current limiting required)

Voltage Input UL: 90V L-N to 600V L-L ; CE:

90V L-N to 300V L-L

Current Input

Scaling 5A to 32,000A

Input Range 0 to 0.333V or 0 to 1V (selectable)

Pulse Inputs

(AMP4)

Contact inputs to pulse accumulators (one set with AMP4; two sets with AMP4)

Accuracy:

Real Power and Energy

0.5% (ANSI C12.20, IEC 62053-

22 Class 0.5S)

Outputs:

All Models (except AMP4)

Real Energy Pulse: N.O. static;

Alarm contacts: N.C. static

AMP1 Reactive energy pulse

30VAC/DC

AMP2 & AMP3 RS-485 2-wire Modbus® RTU (1200 baud to 38.4 kbaud)

AMP4 RS-485 2-wire BACnet MS/TP (9600 baud to 115.2 kbaud)

Mechanical:

Mounting DIN Rail or 3-point screw mount

Environmental:

Operating Temperature Range

-30° to 70°C (-22° to 158°F)

Storage Temperature Range

-40° to 85°C (-40° to 185°F)

Humidity Range <95% RH noncondensing

Safety UL508, EN61010

AMP1B1 AMP1C2 AMP1C3 AMP1H5

Speedi Mod Code E5P E5M E5MD E5BD

Measurement Capability - Full Data Set

Bi-directional Energy Measurements

Power (3-phase total and per phase):

Real (kW) Reactive (kVAR), and Apparent (kVA)

Power Factor: 3-phase average and per phase

Present Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA)

Import and Export totals of Present Power Demand:

Real (kW), Reactive (kVAR), and Apparent (kVA)

Peak Power Demand: Real (kW), Reactive (kVAR), and Apparent (kVA)

Current (3-phase average and per phase)

Voltage: Line-Line and Line-Neutral (3-phase average and per phase)

Frequency

Accumulated Net Energy: Real (kWh), Reactive (kVARh), and Apparent (kVAh)

Import and Export Accumulators of Real and Apparent Energy

Reactive Energy Accumulators by Quadrant (3-phase total and per phase)

Demand Interval Configuration:

Fixed or Rolling Block

Demand Interval Configuration:

External Sync to Comms

Data Logging

Data Logging: 10 16-Bit Configurable (can include Date/Time) Data Buffers

Data Logging: 3 Timestamped 32-Bit Configurable Data Buffers

Store up to 60 days of readings at 15-minute intervals

Outputs

Alarm Output (N.C.)

1 Pulse Output (N.O.)

2 Pulse Outputs (N.O.)

RS-485 Serial (Modbus® RTU Protocol)

RS-485 Serial (BACnet MS/TP Protocol)

LON FT Serial (LonTalk Protocol)

Inputs

2 Pulse Contact Accumulator Inputs

1 Pulse Contact Accumulator Input

Selection Guide

References

Amp-series Quick install DET-783 AMP1B1, C2, C3 install DET-784 AMP1H5 install DET-785

Product Specifications COMMSO PE®

Representative Image

Broadband Solutions

810008877/DB 00 l 2-LN-8W-F l 23G/25TIAJ Single Alternative Jacket All-Dielectric, Gel-Filled, Outdoor Stranded Loose Tube Cable

Alternate MOPE Outer Jacket

Binder Water Swellable Tape

Ripcord (1) Binder

2.5mm Gel-Filled Buffer Tubes 250 micron Fibers

Dielectric Strength Member

General Specifications Cable Type Construction Type Subunit Type

Construction Materials Fiber Type Solution Jacket Material Total Fiber Count Fiber Type Fiber Type, quantity Fibers per Subunit, quantity Jacket Color Jacket UV Resistance

Dimensions Buffer Tube/Subunit Diameter Cable Weight Diameter Over Jacket Filler, quantity Subunit, quantity

Physical Specifications Minimum Bend Radius, loaded

Stranded loose tube Non-armored Gel-filled

LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.Al ) ternaLive jacket PE

[2

LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.Al )

Black UV stabilized

2.50 mm I 0.10 in

71.0 kg/km I 48.0 lb/kft 10.rn mm I 0.40 in

15.2 cm I 6.0 in

Minimum Bend Radius, unloaded 10.1 cm I 4.0 in Tensile Load, long term, maximum 800 N I 180 lbf Tensile Load, short term, maximum 2700 N I 607 lbf Vertical Rise, maximum 1153.0 m I 3781.0 ft

©20 l 5 CommScope, Inc. All righls reserved.All lrademorks idenlified by ® or TM ore regislered lrademarks, respeclively, of CommScope All specifications ore subject la change wilhoul nolice . See www.commscope .com for the masl current informalion. Revised: November 21 , 201 5 page l of 2 December 21 , 2015

Product Specifications COMMSG PE

810008877/DB I OD1 2-LN-8WF1 23G/25T/AJ

Environmental Specifications Environmental Space

Installation Temperature Operating Temperature Storage Temperature

Aerial, lashed I Buried -30 °C to +70 °C (-22 °F to +158 °F) -40 °C to +70 °C (-40 °F to +158 °F) -40 °C to +75 °C (-40 °F to +167 °F)

Mechanical Test Specifications Compression Compression Test Method Flex

22 N/mm

FOTP-41

35 cycles

125 lb/in

!EC 60794-1 E3

Flex Test Method Impact

Impact Test Method Strain Strain Test Method Twist Twist Test Method Water Penentration

FOTP-104 I !EC 60794-1 E6

2.94 N-m I 2.17 ft lb

FOTP-25 I !EC 60794-1 E4

See long and short term tensile loads FOTP-33 !EC 60794-1 El

10 cycles

FOTP-85 !EC 60794-1 E7

24 h

Water Penentration Test Method FOTP-82 !EC 60794-1 FS

Environmental Test Specifications Cable Freeze Cable Freeze Test Method Drip

Drip Test Method Heat Age Heat Age Test Method Low High Bend Low High Bend Test Method Temperature Cycle Temperature Cycle Test Method

-2 °C I 28 °F FOTP-98 I !EC 60794-1 Fl5

70 °C I 158 °F

FOTP-81 I !EC 60794-1 E14

-40 oc to +85 ac (-40 Of to +185 Of )

!EC 60794-1 F9

-30 °C to +60 °C (-22 °F to +140 °F) FOTP-37 I !EC 60794-1 Ell -40 °C to +70 °C (-40 °F to + 158 °F) FOTP-3 I !EC 60794-1 Fl

Qualification Specifications Cable Qualification Standards ANSI/ICEA 5-87-640 I EN 187105 I Telcordia GR-20

Regulatory Compliance/Certifications Agency RoHS 2011/65/EU

ISO 9001: 2008

Included Products

Classification Compliant Designed, manufactured and/or distributed under this quality management system

CS·BW·LT (Product Component-not orderabie) -TeraSPEED® OS2 Singlemode Fiber

©2015 CommScope, Inc All rights reserved All trademarks identified by ® or TM ore registered trademarks, respectively, of CommScope.

All specifications ore subject to change wilhout nolice See www commscope .com for the most current information . Revised: November 21 , December 2 l, 20 l5

PENTAIR

H20MIT™ VENT DR AINS

INDUSTRY STANDARDS

Maintains UL/cU L Type 4, 4X rating when pro perly installed on a UL/cU L Type 4 or 4X enclosure, U L 508A Listed; Ty pe 4, 4X; Fi le No. E61997 c U L Listed per CSA C 22. 2 No 94; Ty pe 4, 4X; Fi le No. E61997

N EM A/E E MAC Ty pe 4, 4X

I EC 60529, I P66

APPLICATION

H 20 M IT™ Vent Drai ns allow accu m u la ted wa ter to d rai n ou t the bot tom of a n enclosu re. The U L-a pproved ve nt d rai ns a lso f u nction as an ai r pressu re eq ua lizer, red uci ng the ha rmf ul ef f ec ts of tempera tu re-i nduced vacu u ms that cou ld pu ll water and moistu re i nto t he enclosu re.

ACCESSORIES CONDENSATION MANAGEM E NT

FEATURES

Uses g ravi ty to rem ove collected liq uids O ne-wa y mec ha nica l shu t-of f when pressu re i s eq ualized p reve n ts wa te r a nd conta mi na nts f rom en te ri ng t he e nclosu re Helps red u ce co r rosio n tha t ca n li mi t the life of i nterna l elec t rica l a n d electronic com po nents I nsta lls i n a 7/8-i n. hole i n t he bot tom of e nclosu re wi th p rovided n u t o r i n a 1/2-in . N PT/N PS t h readed co n d ui t h u b I nsta lls i n t h e bottom of mild steel, a lu m i n u m , stainless steel o r non -m etallic enclosu res

• Ma i n tai ns e nclosu re's U L Type rati ng whe n pro perly i nsta lled

SPECIFICATIONS

Stainless Steel Vent Drain

• Corrosion-resista nt polyester ma terial wi th a Type 304 stainless steel sleeve

• 2.00-i n. long x 1.38-in ou tside dia m ete r Non-Metallic Drain Vent

Corrosio n -resista nt polyester mate rial

• 2.00-i n. long x 1.25-i n. ou tside dia meter

Pe rfo rma n ce Da ta H20MIT Vent Drains

• • t r

AVDR4Ntv1 AVDR4SS4

Non -metallic Vent Drain

1.25 32

Stainless Steel Vent Drain

1.38 35

COOLING SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SOLUTIONS

Spec-00542 I

ACCESSORIES CONDENSATION MANAGEMENT

H20MIT Vent Drains

<,b D mm

87937537

EQUIPMENT PROTECTION SOLUTIONS

Spec-00542 I

PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE .COM COOLING 2

2.

1.95 SO mm

PENTAIR ACCESSORIES ENCLOSURE KEATERS

Pe rfo r ma n ce Data 100 a n d 200 Watt Heaters

ELECTRICAL DATA

OAH1001A DAH1002A DAH2001A OAH2002A

Rated Voltage 115 230 Frequency !Hz) 50/60 50/60 Power Consumf!lion !Watts) 100 100 Nominal Current IAmpsl 0 .98 0.49

HEATING PERFORMANCE

Watts 100 100

UNIT CONSTRUCTION

Weight llb./kgl 1.6/0 "/3 l.6/D.73 X lin.lmml 4 0011 U2 4.00/102

Pe rfo rm a n ce Data 400 a n d 800 Watt Heaters

115 230 50/6 0 50/60 200 200 q _ g9 0 .95

200 200

1 6/0 'l3 1.6/0.73

6 001152 6.00/152

CATALOG NUMBERS

DAH4001B DAH4002B DAH8001 B DAH8002B

ELECTRICAL DATA

Rated Voltage 115 230 115 230 Frcquenc.y [Hz) 50/60 50/60 50/60 50/60 Power Consumption JWalls) 400 400 800 800 Nominal Currenl (Ampsl 3.72 Ul6 7.37 3 .69

HEATING PERFORMANCE

Watts 400 400 800 800

UNIT CONSTRUCTI ON

Weight ILb./kgl 2.2/1.00 2.211.oa 2.2/1.00 2.211.00 X lin./mml 6.00/152 1>.oo/1s2 8.007203 8. 00/203

Perfor ma n ce Da ta 1300 Watt Heaters

ELECTRICAL DATA

DAH13001C DAH13002C

Rated Voltage 115 230 Fre uenc IHz) 50/60 50/60 Power Consumpilon Walls 1 00 300 Naminal Current (Amps) 11.5 5."/

HEATING PERFORMANC E

Watts 1300 1300

UNIT CONSTRUCTION

Weight ltt>]kg) 3.4/1.54 3.4/1.54 x !lnJmml 8.00/203 8.00/203

5 COOLING SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Spec-00051 M

507F

Fiber Inter face Device!

Slack Storage Unit

Equipped with Drop and OSP Fiber Slack Storage

Rugged Plastic Housing with Separate Entry Points for OSP Fiber and Customer Fiber

Terminates up to 12 Single Cables Accomodates Multiple Sizes of LB Fittings

Compact, Craft-Friendly Design Allows for Fiber Slack Storage Up to SOft.

Designed to GR-771

Tii Technologies Inc.

Corporate Headquarters:

141 Rodeo Drive Edgewood, NY 11717 Phone: 631.789.5000 ·Fax: 631.789.5063 Toll Free: 888.844.4720 sales@tiitech.com

Locations:

South March Long March Industrial Estate Daventry, Northamptonshire, NNl 1 4PH, UK Phone: +44 (0) 1327 301853 Fa +44 00) 1327 879532 sa les@tiitech.co.uk

Av. Jose de Escandon y Helguera No. 21 Ciudad Industrial Matamoros, Tamaulipas, C.P. 87494, Mexico Phone: 868.812.8011 ·Fax: 868.812.8025 salesmx@tiitech.com.mx w w w .t ii te c h . com

The 507F Fiber Interface Device/Slack Storage Unit is a compact unit which features connectivity between the OSP fiber drop and customer fiber drop, as well as slack storage. This unit accomodates multiple sizes of LB fittings and allows for termination through conduit at the top and bottom of the unit.

The 507F is configurable for 1 to 12 fiber adapters. The unit is available without SC adapters for slack storage applications and is able to store up to 50 of fiber.

KEY PRODUCT BENEFITS

Provides SC demarcation point between outdoor fiber drop and customer premise fiber

Accomodates multiple LB fittings

Allows for termination through conduit at the top and bottom of the unit

Constructed of superior materials capable of withstanding harsh outdoor environments, including UV degredation, chemical exposure, and extreme temperatures

.. Designed for bend sensitive fiber installations with up to 3 inch bend radius

.. Corner slack retention features retain "springy" OSP and bend sensitive fiber

.. Entry grommets accept up to 1 inch conduit with provision for tie wrap retention

.. 2X internal tie down features for proper strain relief of fiber cables

Knockouts on back provide alternate entry scheme for fiber mini duct tubing

.. Hinged cover fits securely on the base to provide maximum protection against environmental conditions and intrusion of foreign matter, protecting sensitive fiber connectivity lti> Cover closes securely with 3/8" hex head bolt and has a provision for a tie-wrap

INDUSTRY STANDARDS

Meets GR-771 Requirements

Dimensions are in Inches

O R D E R I N G I N F O R M A T I O N

M o d e l N u m b e r M a t r i x

507F -XX

Adapter Plate xx xx

Adapter Type # of Adapters

01 = Fiber Plate (1,2, or 4 adapters only)* 02 = Fiber Plate (6 Adapters) 03 = 1.5" Fiber Storage Tray 04 = Fiber Plate (12 Adapters)

01 = SC-APC

02 = SC-UPC

01 = 1 02 = 2 03 = 3 04 = 4 06 = 6

12 = 12

* Can be sold individually in packages of 50 per carton (Model #: FP01-01-01 )

Rl

-3.19 -

11.19 s p e c i f i c a ti o n s Category 6/Class E, punchdown patch panels shall terminate 4-pair, 22 - 26 AWG, 100 ohm unshielded twisted pair cable with an industry standard single wire 110 punchdown tool. Patch panels shall include a universal label coded for T568A and T568B wiring schemes and mount to 19" and 23" racks. Patch panels shall be easy to identify with pre-printed numbers, write-on areas and optional label kits.

t e c h n i c a l i n f o r m a t i o n .,,.... -- = ---:::

Category 6/Class E Exceeds channel requirements of ANSl/TIA-568-C.2 Category 6 and channel and component ISO 11801 Class E standards at swept frequencies 1 to 250 MHz performance:

FCC and ANSI compliance:

/EC compliance:

PoE compliance:

UL rated:

Conductor termination range:

Mounting option:

Exceeds component requirements of ANSl/TIA-568-C.2 Category 6 and ISO 11801 Class E standards at swept frequencies 1 to 250 MHz Meets all applicable ANSl/TIA-968-A requirements ; contacts plated with 50 microinches o old for superior performance___ Meets IEC 60603-7 Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications UL 1863 approved Compatible with 22 - 26 AWG solid or stranded IWC cable with conductor insulation diameters of 0.048 in.

Mounts to standard EIA 19" or 23" racks (with optional extender

CM (Fo.oJ le.ngths): l:JTPSP"Y CM (Meter lengths): WTPSf>MMY tSZH (Meter lengths): l!JTPSPLMMY

Packaging:

bracket); 12-port version can be wall mounted with optional 890 bracket Includes M6 and #12-24 mounting screws

Wire snipping tool:

Wire strfpplng tool:

Punchdown tool:

24·p.ott label kit:

ows;r

€.!AST

POT11'0

QPLK24

k e y f e a t u r e s a n d b e n e fi t s 48-port label kit:

Replacement module:

DPLk48

DAJ688TGBL

100% performance tested Confidence that each jack module will deliver the critical electrical performance requirements Strain telief bar:

Extender bracket:

Clear dust c;ip:

SRBM19BLY

PEB1 -

Mr:fc-c

Individually seriallzed Each port is marked with quality control number for future traceability RJ45 interface Industry standard interface provides a quick and easy plug and play connection to RJ45 patch_cor backwards compatible

Block out del.(ice_:

Phone icons:

Data Icons:

PSl-DCJB..AM CIPIW-C:t:

CIDIW-C:t:

Identification

Universal wiring scheme Industry standard termination tool Block out device (optional)

Can be clearly identified with optional labels and icons for port identification T568A and T568B wiring schemes clearly identified Single wire 11O punchdown tool (PDT110) ensures conductors are fully terminated Provides a simple and secure method to control access to data

'To designate color, add suffix BU (Blue) or WH (White). For additional cable colors, contact customer service.

"For lengths 1 to 20 feet (one foot increments) and 25, 30, 35, 40 feet, change the length designation in the part number to the desired length. For standard cable colors other than ports while not in us_e _ Off Whtte,add suffix BL (Black), BU (Blue), RD (Red),YL (Yellow),GR (Green), OR (Orange)

Angled design (optional)

Replacement port module (optional) a p p li c a t i o n s

Facilitates proper bend radius control and minimizes the need for horizontal cable managers Ability to replace field damaged ports for complete panel utilizations or VL (Violet). For example, the part number for a blue 15-foot patch cord is UTPSP15BUY.

/\/\ For lengths 1 to 10 meters (one meter increments) and 2.5, 15, 20, 25, 30, 35, 40 meters, change the length designation in the part number to the desired length. For standard cable colors other than Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet).For example, DP6'" PLUS Punchdown Patch Panels are a component of the TX6™ PLUS UTP Copper Cabling System. This end-to-end system is interoperable and backwards compatible, providing design flexibility to protect network investments well into the future. With certified performance to the ANSl/TIA-568-C .2 Category 6 and ISO 11801 Class E standards, this system is ideal for today's high performance workstation applications. With certified performance to the ANSl/TIA-568-C.2 Category 6 and ISO 11801 w w w . pa n d u i t .com

Class E Edition 2.1 standards, these systems will support the following applications:

• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet)

• 155 Mb/s ATM, 622 Mb/s ATM,

1.2 Gb/s ATM

• Token Ring 4/16

• Digital video and broadband/baseband analog video

• Voice over Internet Protocol (VoIP) the part number for a blue 15·meter patch cord is UTPSP15MBUY.

/\/\/\To designate color other than Red, add suffix BL (Black), BU (Blue), YL (Yellow), GR (Green), OR (Orange), IW (Off White) or IG (International Gray) at the end of the part number. 10/package.

:j:To designate color other than IW (Off White), replace IW with El (Electric Ivory), IG (International Gray), BL (Black), BU (Blue), RD (Red), YL (Yellow) , GR (Green) , OR (Orange) or VL (Violet) in the part number.

100/package.

Te s t R e s u lt s

Mechanical Test Test Method Measurement Typical Test Results Normal Force - Load (qrams) >100 Vibration IEC 512-6d Circuit Resistance (mOhms) <40

Shock IEC 512-6c Contact Disturbance (microseconds) <5

Durability IEC 512-9a Circuit Resistance (mOhms) <40

Mating/Un-Mating IEC 512-13b Mating Force (N) <20

Un-Mating Force (N) <20 Termination Cycles IEC 352 Number of Cycles >20

Electrical Test Test Method Measurement Typ cal Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhmsl <20 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (mOhms) >500

1.00 (25.4)

1-10.0 (254.o) --1 t 10 ·1:·1 -

12-Port DP6 · PLUS Patch Panel L2.09

_L 1---- 17.42 (442.5) ----<-

(53.2)

24-Port DP6" PLUS Patch Panel L1.12 (43.7)

4.75 (120.6)

48-Port DP6'" PLUS Patch Panel L_ 3.47 (88.1)

. ' . -i_

24-Port DP6'" PLUS Angled Patch Panel (!J.) 48- Port DP6'" PLUS Angled Patch Pane-;-L3.47 (88.1)

Dimensions are in inches. [Dimensions in brackets are metric].

WORLDWIDE SUBSIDIARIES AND SALES OFFICES

PANDUIT CANADA

Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300

PANDUIT EUROPE LTD.

London, UK cs-emea@panduit.com Phone: 44.20.8601. 7200

PANDUIT SINGAPORE PTE. LTD.

Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575

PANDUIT JAPAN

Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000

PANDUIT LATIN AMERICA

Jalisco, Mexico cs-la@pandui t.com Phone: 52.33.3777 .6000

PANDUIT AUSTRALIA PTY. LTD.

Victoria, Australia cs-aus@panduit.com Phone: 61 .3.9794.9020

For a copy of Panduit product warranties, log on to www.panduit.com/warranty

For more information Visit us at www.panduit.com

Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 and reference COSP45

©2010 Panduit Corp.

ALL RIGHTS RESERVED .

WW-COSP45

4/2010

,.,............."'t"" ......_,.. ...,....... -• ---17.42(442.5)----

Environmental Test Test Method Measurement Typical Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) <40 Humidity IEC 512-11c Circuit Resistance (mOhms) <40

Thermal Shock IEC 512-11d Circuit Resistance (mOhms) <40

Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) <40

Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) <40

Brocade ICX 6430 and 6450 Switches Page 1 of 2 https://www.brocade.com/ en/backend-content/pdf-page.html? Icontent/dam/common/docu... 2/ 10/2016

DATA SHEET

Enterprise-Class Stacka Today's organizations expect more services to more users · generation business applicati for mobile devices. At the sa scale easily to meet future de business environments.

HIGHLIGHTS

• Offers enterprise-class stackable switching at an entry-level price, allowing organizations to buy what they need

Brocade" ICX" 6430 and 6450 Sw provide enterprise-class stackable switching solutions to meet the gro

Brocade ICX 6430 and 6450 Switches Page 2 of 2 https://www.brocade.com/ en/backend-content/pdf-page.html? Icontent/dam/common/ docu... 2110/2016

Brocade ICX 6610 Switch Page 1 of 2 https://www.brocade.com/ en/backend-content/pdf-page.html? Icontent/ dam/common/docu... 2110/2016

DATA SHEET

HIGHLIGHTS

• Delivers chassis-level performance and availability, providing an optimal user

Chassis-Like Capabilitie Today's enterprise networks a impossible just a few years a real-time collaboration. Unifie Desktop Infrastructure (VDI) organizations are deploying t customer service. and create networks must also provide a to meet rising user expectatio continued pressure to reduce ever. campus networks need

Brocade ICX 6610 Switch Page 2 of 2 https ://www.brocade.com/ en/backend-content /pdf-page.html? /content/dam/common/docu... 2/ 10/2016

• Sunlight-viewable Touchscreen with

Panasonic Circulumin'" Technology

• Full Magnesium Alloy Case with Handle

• 18-hour Battery Life !27 Hours with Optional Media Bay 2nd Battery)

• Standard Backlit Keyboard

• Optional 4G LTE Multi Carrier Mobile Broadband with Satellite GPS

UPS51

c-PDOl1 DRCll' R/ITING

MlbSTS-

81QG

POWERFUL, RUGGED AND WIRELESS.

Panasonic presents the Toughbook® 31, the reliable laptop offering the world's most rugged design. With drop-shock protection and a MIL-STD-81 OG certification, it's the undisputed leader in the fully rugged category. Its new

Intel® Core'" i5 processor packs a punch to deliver desktop-class performance and amazing battery life-18 hours, or 27 hours with optional media bay 2nd battery. Combine six generations of delivering rugged performance plus 15 years of consistent docking compatibil ity, and you have a computer that will go the distance with you anytime. anywhere.

1.800.662.3537 panasonic.com/toughbook/31 ITOUGHBOOK®I

Panasonic

ITOUGHBOOK I

TOUGH BOOK 31

) :.-·"'l•>l .. ""-"'"""••1·· ::."""""""'I

Panasonic reco mmends Windows.

SOFTWARE • Windows 8 1 Pro 6Li-bil (available Windows"' 7 Pro[ess1onal downgrade option]

• PanasonK UL1lil1es, Recovery Parlilion

DURABILITY • MIL-ST0-810G cerLir1ed 16' drop, shock, v1bral1on, rain, dust, sand, all1lude, freeze/lhaw. high/low lemperalure, lernperalure shock, hum1d1Ly, explosive almospherel 1

• MIL-ST0-461F cerl1f1ed

• IP65 cerlif1ed sealed all-weather design

• Hard dnve healer

• Full magnesium alloy case w1lh handle

• Shock-mounled flex-connecl hard drive w1lh quick-release

• Reinrorced locking port covers

• Pre-1nslalled replaceable screen film for Louchscreen prolecl1on

CPU' • lnlel ' Core' i5-5300U vPro ' Processor

- 2 JG Hz w1lh Turbo Boosl up lo 2 9GHz

- 3MB cache

STORAGE & MEMORY o 6GB-16GB SDRAM [OOR3L-1600MHzP'

• Shock-mounled flex-connecl hard drive w1lh quick-release

- 500GB 7200rpm wilh heale

- Oplional 128GB, 256GB and 512GB solid slale drives ISSD) w1lh healers'·

DISPLAY • 13 1" XGA sunl1ghl-v1ewable louchscreen LED 102/i x 768

- Panasomc C1rculum1n ·technology

- 2-1200 nil

- Circular polarizer

- Anl1-reflecl1ve and anl1-glare screen lrealmenls

• HD Graphics 5500, max 1785MB shared VRAM w1Lh Windows 8 1 32-bitJ

SECURITY FEATURES

• Password Secunly: Supervisor, User, Hard Disk Lock

• Kensington cable lock slol

• Trusted platform module ITPMI securily chip v 1 2

• Compulrace , LherL prolecl1on agent in BIOS"

• lnlel Anli-Thefl Technology

• Opl1onal ftngerprinl reader

• Optional inserlable SmartCard reader

WARRANTY

• 3-year lim1Led warranly, parls and labor

DIMENSIONS & WEIGHT

• 11 5"[LJ x 11 9"[WJ x 2 9' [HI

• 7 9 lbs (8 2 lbs wilh oplional media bay 2nd ballery]

INTEGRATED OPTIONS'

• LiG LTE mulli carrier mobile broadband w1Lh salell1le GPS

• GPS [u-blox NED-M8NJ

• Webcam

• 2nd LAN or F1reW1re

• lnserlable SmarlCard reader

• Fingerprinl reader

• Media bay 2nd ballery

• HOD and bal lery lock

• 128GB, 256GB and 512GB solid slate dnves !SSDI wilh healers

SELECT ACCESSORIES'

• Exlernal video support up Lo 1280 x 1024 al 16 7 m1llton colors

• Concealed mode konf1gurable)

AUDIO • lnlelco h1gh-delm1Lion audio compl1anl

• lnlegraled front-racing speaker

• Keyboard volume and mule conlrols

KEYBOARD & INPUT • Touchscreen

• lnlegraled slylus holder

• 87-key wrlh ded1caled Windows key

• Backlit keyboard

- Sealed rubber or plastic em1ssive

• Pressure-sensitive Louch pad wilh verlical scrolling supporl

• AC Adapter [3-prongl

• Long Life Ballery Pack

• Media Bay 2nd Ballery

• Ballery Charger

• LIND 3-Bay Ballery Charger e LIND Car Adapter 120W

• ToughMale ComUnivP.rsnl

Carrying Case llarge capac1ly]

• ToughMale Backpack

• ToughMale Sling 31 Case

• DVD Super MULTI Drive

• Memory Cards

- 6GB OOR3

- 8GB OOR3

CF-AA5713AM

CF-VZSU66AU

CF-VZSU1631U

CF-VCBTB2W

PACH329-1857-P

CF-LNOOC120

TBCCOMUNV-P

TBCBPK-P

TBC31CASE-P

CF-VDM312U

CF-WMBA1306G

CF-KBA508GM

MULTIMEDIA BAY • Opl1onal DVD Super MULTI Dnve or Media Bay 2nd ballery • Desktop Dock CF-VEB31 lU

EXPANSION SLOTS • PC card Lype II x 1

• SD card ISDXCI

• ExpressCard/5Li x 1

INTERFACE • Docking conneclor 80-pin

• HDMI Type A

• VGA 0-sub 15-pin

• Headphones/speaker Mini-Jack slereo

• M1crophone/l1 ne in Mini-Jack slereo

• Senal D-sub 9-pin

• Exl anlenna conn 50 ohm coaxial

• USB 3 0 [x 1I, USB 2 0 [x 31 Type A

• Optional I EEE 139Lia IF1reWire] 4-pin

• 10/100/1000 Elhernel RH5

• Opl1onal 10/100/1000 2nd LAN (Elherncl) RJ-ii5

WIRELESS • Opl1onal 1 nlegraled 4G LTE mull1 carrier mobile broadband wilh salell1Le GPS

• Opl1onal GPS (u-blox NEO-MBN)

• Vehicle Docks lno pass-through]

- Panasonic

- Gamber-Johnson w1lh LIND power supply

- Havis w1lh LIND power supply

• Vehicle Docks !single pass-Lhroughl

- Panasonic

- Gamber-Johnson w1Lh LI ND power supply

- Havis wrlh LIND power supply

• Veh1ele Docks ldual pass-lhrough]

- Panasonic

- Gamber-Johnson w1Lh LIND power supply

- Havis w1Lh LIND power supply

• Touchscreen Large Stylus wilh Tether Hole a Telher

• 13 l" LCD Proleclor Film

CF-WEB301M

7160-0318-06-P

CF-H-PAN- 112-P

CF-WEB301 MA

7160-0318-05-P

CF-H-PAN-112-1-P

CF-WEB301 MB

7160-0318-06-P

CF-H-PAN- 112-2-P

CF-VNP009U

CF-VNT002U

CF-VPF15U

• Inlet Dual Band W1reless-AC7265 802 1 la/b/g/n/ac

• Blueloolh" v4 0 + EDR [Class 1]

• Secunly

- Aulhenl1cation: LEAP, WPA, 802 l x, EAP-TLS, EAP-FAST, PEAP

- Encrypl1on: CKI P, TKI P, 128-bil and M-b1L WEP, Hardware AES

Ill User-selectable an Lenna pass-lhrough I dual standard, single optional]

• Slide on/ofl sw1lch

POWER SUPPLY • Biiur:ry o.1:H!rnuci.r1 18 ho,.ir f27h'w'l\h a-pi 1on11r m1 tmv ?fiid ba1t111yi'

• Lung l•lo l.i·lon h•ll••.r pock l106SV. twical 85>0inN•, mu11murn 8l00mMI

• Biilllfrych,iracr lln'KI J,5 h.aur.; cm/olf l7 hourr;; wt lh ippuon:t! mtrd 1.1 hilYimi bii llery]'

• JtC Ada.11tt)r· 2_nDtl·?41lV 5QIM>H1.. DU\!lilll19/w11JcJt1119 ufc pow11r supply

Please consult your reseller or Panasonlc represenlalive belore purchasing

1…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .