FA520517R0004_Atch2_Drawings_3_Structural.pdf

PDF 885 KB Posted

Attached to
Improve Military Family Housing (IMFH) Phase III, A/C and Weatherization, Misawa Air Base, Japan
Solicitation number
FA5205-17-R-0004
Issued by

About this file

FA520517R0004_Atch2_Drawings_3_Structural

View the file

Other files

File Type Posted
FA520517R00040005_Amendment.pdf PDF
FA520517R00040005_Atch3.pdf PDF
FA520517R00040005_Atch1.pdf PDF
FA520517R00040005_Atch4.pdf PDF
FA520517R00040005_Atch7.pdf PDF
FA520517R00040005_Atch6.pdf PDF
FA520517R00040005_Atch2.pdf PDF
FA520517R00040005_Atch5.pdf PDF
FA520517R00040004_Atch4.pdf PDF
FA520517R00040004_Amendment.pdf PDF
FA520517R00040004_Atch3-4.pdf PDF
FA520517R00040004_Atch3-3.pdf PDF
FA520517R00040004_Atch5.pdf PDF
FA520517R00040004_Atch1.pdf PDF
FA520517R00040004_Atch2.pdf PDF
FA520517R00040004_Atch3-5.pdf PDF
FA520517R00040004_Atch3-2.pdf PDF
FA520517R00040004_Atch3-1.pdf PDF
FA520517R00040003_Atch1.pdf PDF
FA520517R00040003_Atch2.pdf PDF
FA520517R00040003_Amendment.pdf PDF
FA520517R00040002_Amendment.pdf PDF
FA520517R00040002_Atch.pdf PDF
FA520517R00040001_Atch2_Revised_Specification_Section.pdf PDF
FA520517R00040001_Amendment.pdf PDF
FA520517R00040001_Atch4_Revised_Solicitation_Page.pdf PDF
FA520517R00040001_Atch1_Addendum_No._1.pdf PDF
FA520517R00040001_Atch3_Revised_Drawings.pdf PDF
FA520517R0004_PreProposal_Conference_Minutes_&_Record_of_Site_Visit.pdf PDF
FA520517R0004_Atch2_Drawings_8_Electrical.pdf PDF
FA520517R0004_Atch2_Drawings_6_Plumbing.pdf PDF
FA520517R0004_Atch10_Asbestos_Sampling_and_Analysis.pdf PDF
FA520517R0004_Atch2_Drawings_2_Hazmat.pdf PDF
FA520517R0004_Atch2_Drawings_5_Mechanical.pdf PDF
FA520517R0004_Atch4_PPQ_Cvr_Ltr.pdf PDF
FA520517R0004_Solicitation.pdf PDF
FA520517R0004_Atch8_Acceptable_JPN_Product_Substitutes.pdf PDF
FA520517R0004_Atch2_Drawings_7_Controls.pdf PDF
FA520517R0004_Atch2_Drawings_4_Architectural.pdf PDF
FA520517R0004_Atch9_Mfr's_Cut_Sheet_Catalog_Info.pdf PDF
FA520517R0004_Atch2_Drawings_1_General.pdf PDF
FA520517R0004_Atch3_Other_Contract_Requirements.pdf PDF
FA520517R0004_Atch1_Specifications.pdf PDF
FA520517R0004_Atch6_Construction_Timeline.pdf PDF
FA520517R0004_Atch5_PPQ.pdf PDF
FA520517R0004_Atch7_Schedule_of_Material_Submittals.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B

A C wp

STEAM

METER

CONTROL

PANEL

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

D. H. W SUPPLY PUMP

D. H. W RETURN HEADER

D. H. W SUPPLY HEADER

H. W SUPPLY HEADER

NO. 1

D. H. W STORAGE TANK

NO. 2

D. H. W STORAGE TANK

EXPANSION TANK

STEAM HEADER

HEAT EXCHANGER for H. W

H. W RETURN HEADER

H. W SUPPLY PUMP

NO. 1

NO. 2

NO. 1

NO. 2

1 3 1 3

1 21 2

1 3

1 3

B

A C

EXIST POWER

PANEL BOARD EXIST PLC

CABINET

RP - 1

STEAM

METER

CONTROL

PANEL

D. H. W SUPPLY PUMP

D

H

W

R

E T

U R

N

H

E A

D E

R D

H

S

U P

P L

Y

H

E A

D E

R

NO. 2

D.H.W STORAGE TANK

NO. 1

D. H. W STORAGE TANK

EXPANSION TANK

STEAM HEADER

HEAT EXCHANGER for H. W

H

T

U R

N

H

E A

D E

R

H. W SUPPLY PUMP

NO. 2

NO. 1

NO. 2

NO. 1

H. W SUPPLY HEADER

1 3

1 3

1 2

1 3

1 3

SHEET OF

SHEET

IDENTIFICATION

O N

E I D

A

T

O T

A L

I N

T E

G R

A T

D

T

E R

P R

I S

E S

M

A Y

F A

O A

D

S

U I T

E

M I L

W A

U K

E E

W

I

F A

D

S O

L

B

N

U M

B

I S

O

A

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S O

L I C

I T

A T

I O

N

N

O

D A

T E

C O

N T

R A

C T

D R

A W

I N

G

C

O D

E

I S

S U

E

D

A T

E

P L

A

L E

S U

B M

I T

T E

D

B

Y

F I L

E

N

A M

E

S I Z

E

P D

C

Q

K K

A

M I S

A W

A

A

S

E

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N

D A

T E

A P

P R

THIS WORK WAS

PREPARED BY ME OR

UNDER MY SUPERVISION

FINAL DOCUMENTS

OF

U S

A

F

R

C E

C I V

G

I N

E E

R

S

Q U

A D

R O

N

A F

Oneida Total Integrated Enterprises

T I M

O T

H Y

W

E N

D T

T T

W

KEY PLAN

MAIN BASE

GENERAL PLAN NOTES:

KEYED NOTES:

REMOVE EXISTING 200 MM TALL HOUSE KEEPING PAD. POLISH SMOOTH TO MATCH ADJACENT SLAB. CUT

ANY AND ALL EXISTING ANCHOR BOLTS AND GRIND SMOOTH.

REMOVE EXISTING STEEL SUPPORT FRAME ALONG WITH ASSOCIATED ANCHOR BOLTS.

REMOVE EXISTING STEEL TUBE COLUMN SUPPORTS ALONG WITH ASSOCIATED ANCHOR BOLTS.

1. PATCHING OF EXISTING CONCRETE WALLS SHALL OCCUR AT (2) LOCATIONS PER PUMPHOUSE, 25MM

PIPE VENT FOR EXPANSION TANK AND 25MM PIPE VENT FOR EXISTING SHELL AND TUBE HEAT

EXCHANGER TO BE REMOVED.

2. COORDINATE REMOVAL AND ABATEMENT OF ASBESTOS CONTAINING MATERIALS FOR ALL UNITS. REFER

TO HAZMAT PLAN SHEETS FOR ADDITIONAL DEMOLITION NOTES.

3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING ALL OPENINGS IN CEILINGS, WALLS AND

FLOORS THAT RESULT FROM DEMOLITION WORK OR REMOVED EQUIPMENT, UNLESS OPENING IS TO BE

REUSED. PATCHING OF OPENINGS OR OTHER DAMAGE IS TO MATCH ADJACENT SURFACES, MATERIALS

AND CONDITIONS. THIS INCLUDES (BUT NOT LIMITED TO) HOT WATER PIPING, STEAM PIPING, DRAIN

PIPING, AND VENT PIPING ASSOCIATED WITH SYSTEMS TO BE DEMOLISHED.

C T

S T

T W

A N

D R

J

B

A C

K E

S

P U

M P

H O

U S

E

S

T R

U C

T U

R A

L

D

E M

O L I T

I O

N

P

L A

N

SCALE: 1:50

0 1000 2000PUMPHOUSE 141 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD101 PH-SD101 SCALE: 1:50

SCALE: 1:50

0 1000 2000PUMPHOUSE 172 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD101 PH-SD101 SCALE: 1:50

A C D

TEL BOX

LIGHTING PANEL

wp

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

STEAM

METER

CONTROL

PANEL

NO. 1

D. H. W STORAGE TANK

NO. 2

D. H. W STORAGE TANK

HEAT EXCHANGER for H. W

E X

P A

N S

I O

N

T

A N

K f o r

H

W

H. W SUPPLY PUMP

SPARE LINE

H. W SUPPLY PUMP

A LINE

H. W SUPPLY PUMP

B LINE

H. W SUPPLY PUMP

C LINE

H

T

U R

N

H

E A

D E

R

STEAM HEADER

D. H. W RETURN HEADER D. H. W SUPPLY HEADER

H

P

P L

Y

H

E A

D E

R

D.H.W RETURN PUMP

SPARE LINE

D. H. W RETURN PUMP

A LINE

D. H. W RETURN PUMP

B LINE

D. H. W RETURN PUMP

C LINE

1 3

1 3

STEAM

METER

B

A C D

P - EB / 706

PANEL BOARD

wp

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

CONTROL

PANEL

NO. 2

D. H. W STORAGE TANK

NO. 1

D. H. W STORAGE TANK

H

P

P

A

D E

R

STEAM HEADER

D

H

T

U R

N

H

E A

D E

R

E X

P A

N S

I O

N

T

A N

K f o r

H

W

HEAT EXCHANGER for H. W

H

T

U R

N

H

E A

D E

R

D. H. W SUPPLY HEADER

D. H. W RETURN PUMP

B LINE

A LINE

SPARE LINE

H. W RETURN PUMP

B LINE

A LINE

SPARE LINE

1 3 1 3

SHEET OF

SHEET

IDENTIFICATION

O N

E I D

A

T

O T

T E

G R

A T

T

E R

P R

I S

E S

M

A Y

F A

A

D

S

U I T

E

M I L

W A

U K

E E

W

I

F A

D

S O

L

B

N

U M

B

I S

O

A

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S O

L I C

I T

A T

I O

N

N

O

D A

T E

C O

N T

R A

D R

A W

I N

G

C

O D

E

I S

S U

E

D

A T

E

P L

A

L E

S U

B M

I T

T E

D

B

Y

F I L

E

N

A M

E

S I Z

E

P D

C

Q

K K

A

M I S

A W

A

A

S

E

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N

D A

T E

A P

P R

THIS WORK WAS

PREPARED BY ME OR

UNDER MY SUPERVISION

FINAL DOCUMENTS

OF

U S

A

R

C E

C I V

G

I N

E E

R

S

Q U

A D

R O

N

A F

Oneida Total Integrated Enterprises

T I M

O T

W

E N

D T

T T

W

KEY PLAN

MAIN BASE

GENERAL PLAN NOTES:

KEYED NOTES:

REMOVE EXISTING 200 MM TALL HOUSE KEEPING PAD. POLISH SMOOTH TO MATCH ADJACENT SLAB. CUT

ANY AND ALL EXISTING ANCHOR BOLTS AND GRIND SMOOTH.

REMOVE EXISTING STEEL SUPPORT FRAME ALONG WITH ASSOCIATED ANCHOR BOLTS.

REMOVE EXISTING STEEL TUBE COLUMN SUPPORTS ALONG WITH ASSOCIATED ANCHOR BOLTS.

1. PATCHING OF EXISTING CONCRETE WALLS SHALL OCCUR AT (2) LOCATIONS PER PUMPHOUSE, 25MM

PIPE VENT FOR EXPANSION TANK AND 25MM PIPE VENT FOR EXISTING SHELL AND TUBE HEAT

EXCHANGER TO BE REMOVED.

2. COORDINATE REMOVAL AND ABATEMENT OF ASBESTOS CONTAINING MATERIALS FOR ALL UNITS. REFER

TO HAZMAT PLAN SHEETS FOR ADDITIONAL DEMOLITION NOTES.

3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING ALL OPENINGS IN CEILINGS, WALLS AND

FLOORS THAT RESULT FROM DEMOLITION WORK OR REMOVED EQUIPMENT, UNLESS OPENING IS TO BE

REUSED. PATCHING OF OPENINGS OR OTHER DAMAGE IS TO MATCH ADJACENT SURFACES, MATERIALS

AND CONDITIONS. THIS INCLUDES (BUT NOT LIMITED TO) HOT WATER PIPING, STEAM PIPING, DRAIN

PIPING, AND VENT PIPING ASSOCIATED WITH SYSTEMS TO BE DEMOLISHED.

C T

S T

T W

A N

D R

B

A C

K E

S

P U

M P

H O

U S

E

S

T R

U C

T U

R A

L

D

E M

O L I T

I O

N

P

L A

N

SCALE: 1:50

0 1000 2000PUMPHOUSE 185 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD102 PH-SD102 SCALE: 1:50

SCALE: 1:50

0 1000 2000PUMPHOUSE 706 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD102 PH-SD102 SCALE: 1:50

A C wp

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

STEAM

METER

CONTROL

PANEL

D

H

P

P

A

D E

R

H. W SUPPLY HEADER

HEAT EXCHANGER for H. W

D. H. W SUPPLY PUMP

D

H

T

U R

N

H

E A

D E

R

NO. 2

D. H. W STORAGE TANK

NO. 1

D. H. W STORAGE TANK

EXPANSION TANK

STEAM HEADER

H

T

U R

N

H

E A

D E

R

H. W SUPPLY PUMP

NO. 2

NO. 1

NO. 2

NO. 1

1 3

1 3

1 3

1 3

1 3

B

A C wp

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

STEAM

METER

CONTROL

PANEL

NO. 2

D. H. W STORAGE TANK

NO. 1

D. H. W STORAGE TANK

HEAT EXCHANGER for H. W

EXPANSION TANK

S T

E A

M

H

E A

D E

R

NO. 1

NO. 2

NO. 1

NO. 2

D. H. W CIRCULATING

PUMP

H. W CIRCULATING PUMP

1 2

SHEET OF

SHEET

IDENTIFICATION

O N

E I D

A

T

O T

T E

G R

A T

T

E R

P R

I S

E S

M

A Y

F A

A

D

S

U I T

E

M I L

W A

U K

E E

W

I

F A

D

S O

L

B

N

U M

B

I S

O

A

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S O

L I C

I T

A T

I O

N

N

O

D A

T E

C O

N T

R A

D R

A W

I N

G

C

O D

E

I S

S U

E

D

A T

E

P L

A

L E

S U

B M

I T

T E

D

B

Y

F I L

E

N

A M

E

S I Z

E

P D

C

Q

K K

A

M I S

A W

A

A

S

E

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N

D A

T E

A P

P R

THIS WORK WAS

PREPARED BY ME OR

UNDER MY SUPERVISION

FINAL DOCUMENTS

OF

U S

A

R

C E

C I V

G

I N

E E

R

S

Q U

A D

R O

N

A F

Oneida Total Integrated Enterprises

T I M

O T

W

E N

D T

T T

W

KEY PLAN

MAIN BASE

GENERAL PLAN NOTES:

KEYED NOTES:

REMOVE EXISTING 200 MM TALL HOUSE KEEPING PAD. POLISH SMOOTH TO MATCH ADJACENT SLAB. CUT

ANY AND ALL EXISTING ANCHOR BOLTS AND GRIND SMOOTH.

REMOVE EXISTING STEEL SUPPORT FRAME ALONG WITH ASSOCIATED ANCHOR BOLTS.

REMOVE EXISTING STEEL TUBE COLUMN SUPPORTS ALONG WITH ASSOCIATED ANCHOR BOLTS.

1. PATCHING OF EXISTING CONCRETE WALLS SHALL OCCUR AT (2) LOCATIONS PER PUMPHOUSE, 25MM

PIPE VENT FOR EXPANSION TANK AND 25MM PIPE VENT FOR EXISTING SHELL AND TUBE HEAT

EXCHANGER TO BE REMOVED.

2. COORDINATE REMOVAL AND ABATEMENT OF ASBESTOS CONTAINING MATERIALS FOR ALL UNITS. REFER

TO HAZMAT PLAN SHEETS FOR ADDITIONAL DEMOLITION NOTES.

3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING ALL OPENINGS IN CEILINGS, WALLS AND

FLOORS THAT RESULT FROM DEMOLITION WORK OR REMOVED EQUIPMENT, UNLESS OPENING IS TO BE

REUSED. PATCHING OF OPENINGS OR OTHER DAMAGE IS TO MATCH ADJACENT SURFACES, MATERIALS

AND CONDITIONS. THIS INCLUDES (BUT NOT LIMITED TO) HOT WATER PIPING, STEAM PIPING, DRAIN

PIPING, AND VENT PIPING ASSOCIATED WITH SYSTEMS TO BE DEMOLISHED.

C T

S T

T W

A N

D R

B

A C

K E

S

P U

M P

H O

U S

E

S

T R

U C

T U

R A

L

D

E M

O L I T

I O

N

P

L A

N

SCALE: 1:50

0 1000 2000PUMPHOUSE 897 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD103 PH-SD103 SCALE: 1:50

SCALE: 1:50

0 1000 2000PUMPHOUSE 61 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD103 PH-SD103 SCALE: 1:50

A C

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

STEAM

METER

CONTROL

PANEL

NO. 2

D. H. W STORAGE TANK

NO. 1

D. H. W STORAGE TANK

EXPANSION TANK

S T

E A

M

H

E A

D E

R

HEAT EXCHANGER for H. W

NO. 1

D. H. W SUPPLY PUMP

H. W SUPPLY PUMP

NO. 2

NO. 1

NO. 2

1 2

B

A C wp

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

CONTROL

PANEL

STEAM

METER

NO. 1

D. H. W STORAGE TANK

NO. 2

D. H. W STORAGE TANK

HEAT EXCHANGER for H. W

EXPANSION TANK for H. W

No. 2

No. 1

No. 2

No. 1

STEAM HEADER

D. H. W CIRCURATING PUMP

H. W CIRCURATING PUMP

1 3 1 3

SHEET OF

SHEET

IDENTIFICATION

O N

E I D

A

T

O T

T E

G R

A T

T

E R

P R

I S

E S

M

A Y

F A

A

D

S

U I T

E

M I L

W A

U K

E E

W

I

F A

D

S O

L

B

N

U M

B

I S

O

A

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S O

L I C

I T

A T

I O

N

N

O

D A

T E

C O

N T

R A

D R

A W

I N

G

C

O D

E

I S

S U

E

D

A T

E

P L

A

L E

S U

B M

I T

T E

D

B

Y

F I L

E

N

A M

E

S I Z

E

P D

C

Q

K K

A

M I S

A W

A

A

S

E

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N

D A

T E

A P

P R

THIS WORK WAS

PREPARED BY ME OR

UNDER MY SUPERVISION

FINAL DOCUMENTS

OF

U S

A

R

C E

C I V

G

I N

E E

R

S

Q U

A D

R O

N

A F

Oneida Total Integrated Enterprises

T I M

O T

W

E N

D T

T T

W

KEY PLAN

MAIN BASE

GENERAL PLAN NOTES:

KEYED NOTES:

REMOVE EXISTING 200 MM TALL HOUSE KEEPING PAD. POLISH SMOOTH TO MATCH ADJACENT SLAB. CUT

ANY AND ALL EXISTING ANCHOR BOLTS AND GRIND SMOOTH.

REMOVE EXISTING STEEL SUPPORT FRAME ALONG WITH ASSOCIATED ANCHOR BOLTS.

REMOVE EXISTING STEEL TUBE COLUMN SUPPORTS ALONG WITH ASSOCIATED ANCHOR BOLTS.

1. PATCHING OF EXISTING CONCRETE WALLS SHALL OCCUR AT (2) LOCATIONS PER PUMPHOUSE, 25MM

PIPE VENT FOR EXPANSION TANK AND 25MM PIPE VENT FOR EXISTING SHELL AND TUBE HEAT

EXCHANGER TO BE REMOVED.

2. COORDINATE REMOVAL AND ABATEMENT OF ASBESTOS CONTAINING MATERIALS FOR ALL UNITS. REFER

TO HAZMAT PLAN SHEETS FOR ADDITIONAL DEMOLITION NOTES.

3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING ALL OPENINGS IN CEILINGS, WALLS AND

FLOORS THAT RESULT FROM DEMOLITION WORK OR REMOVED EQUIPMENT, UNLESS OPENING IS TO BE

REUSED. PATCHING OF OPENINGS OR OTHER DAMAGE IS TO MATCH ADJACENT SURFACES, MATERIALS

AND CONDITIONS. THIS INCLUDES (BUT NOT LIMITED TO) HOT WATER PIPING, STEAM PIPING, DRAIN

PIPING, AND VENT PIPING ASSOCIATED WITH SYSTEMS TO BE DEMOLISHED.

C T

S T

T W

A N

D R

B

A C

K E

S

P U

M P

H O

U S

E

S

T R

U C

T U

R A

L

D

E M

O L I T

I O

N

P

L A

N

SCALE: 1:50

0 1000 2000PUMPHOUSE 227 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD104 PH-SD104 SCALE: 1:50

SCALE: 1:50

0 1000 2000PUMPHOUSE 265 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD104 PH-SD104 SCALE: 1:50

A C D

EXIST

MANUAL XFR SWITCH

EXIST

LIGHTING PANEL

EXIST P - EB / 328

PANEL BOARD

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

CONTROL

PANEL

STEAM

METER

H. W RETURN HEADER

NO. 2

D. H. W STORAGE TANK

NO. 1

D. H. W STORAGE TANK

HEAT EXCHANGER for H. W

EXPANSION TANK for H. W

D. H. W SUPPLY HEADER

H. W SUPPLY HEADER

STEAM HEADER

D. H. W RETURN HEADER

D. H. W RETURN PUMP

A LINE

D. H. W RETURN PUMP

B LINE

D. H. W RETURN PUMP

C LINE

H. W SUPPLY PUMP

SPARE LINE

H. W SUPPLY PUMP

A LINE

H. W SUPPLY PUMP

B LINE

H. W SUPPLY PUMP

C LINE

D. H. W RETURN PUMP

SPARE LINE

1 2

1 3

1 3

1 2

1 2

1 1

B

A C wp

EXIST POWER

PANEL BOARD

EXIST PLC

CABINET

RP -

STEAM

METER

CONTROL

PANEL

D. H. W SUPPLY PUMP

D

H

T

U R

N

H

E A

D E

R D

H

P

P

A

D E

R

H. W SUPPLY HEADER

NO. 2

D. H. W STORAGE TANK

NO. 1

D. H. W STORAGE TANK

EXPANSION TANK

STEAM HEADER

HEAT EXCHANGER for H. W

H

T

U R

N

H

E A

D E

R

H. W SUPPLY PUMP

NO. 1

NO. 2

NO. 3

NO. 1

NO. 2

NO. 3

1 3 1 3

1 2

1 3

1 3

SHEET OF

SHEET

IDENTIFICATION

O N

E I D

A

T

O T

T E

G R

A T

T

E R

P R

I S

E S

M

A Y

F A

A

D

S

U I T

E

M I L

W A

U K

E E

W

I

F A

D

S O

L

B

N

U M

B

I S

O

A

D E

S I G

N E

D

B

Y

D W

N

B

Y

C K

D

B

Y

S O

L I C

I T

A T

I O

N

N

O

D A

T E

C O

N T

R A

D R

A W

I N

G

C

O D

E

I S

S U

E

D

A T

E

P L

A

L E

S U

B M

I T

T E

D

B

Y

F I L

E

N

A M

E

S I Z

E

P D

C

Q

K K

A

M I S

A W

A

A

S

E

A

B

C

D

1 2 3 4 5

M A

R K

D E

S C

R I P

T I O

N

D A

T E

A P

P R

THIS WORK WAS

PREPARED BY ME OR

UNDER MY SUPERVISION

FINAL DOCUMENTS

OF

U S

A

R

C E

C I V

G

I N

E E

R

S

Q U

A D

R O

N

A F

Oneida Total Integrated Enterprises

T I M

O T

W

E N

D T

T T

W

KEY PLAN

MAIN BASE

GENERAL PLAN NOTES:

KEYED NOTES:

REMOVE EXISTING 200 MM TALL HOUSE KEEPING PAD. POLISH SMOOTH TO MATCH ADJACENT SLAB. CUT

ANY AND ALL EXISTING ANCHOR BOLTS AND GRIND SMOOTH.

REMOVE EXISTING STEEL SUPPORT FRAME ALONG WITH ASSOCIATED ANCHOR BOLTS.

REMOVE EXISTING STEEL TUBE COLUMN SUPPORTS ALONG WITH ASSOCIATED ANCHOR BOLTS.

1. PATCHING OF EXISTING CONCRETE WALLS SHALL OCCUR AT (2) LOCATIONS PER PUMPHOUSE, 25MM

PIPE VENT FOR EXPANSION TANK AND 25MM PIPE VENT FOR EXISTING SHELL AND TUBE HEAT

EXCHANGER TO BE REMOVED.

2. COORDINATE REMOVAL AND ABATEMENT OF ASBESTOS CONTAINING MATERIALS FOR ALL UNITS. REFER

TO HAZMAT PLAN SHEETS FOR ADDITIONAL DEMOLITION NOTES.

3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING ALL OPENINGS IN CEILINGS, WALLS AND

FLOORS THAT RESULT FROM DEMOLITION WORK OR REMOVED EQUIPMENT, UNLESS OPENING IS TO BE

REUSED. PATCHING OF OPENINGS OR OTHER DAMAGE IS TO MATCH ADJACENT SURFACES, MATERIALS

AND CONDITIONS. THIS INCLUDES (BUT NOT LIMITED TO) HOT WATER PIPING, STEAM PIPING, DRAIN

PIPING, AND VENT PIPING ASSOCIATED WITH SYSTEMS TO BE DEMOLISHED.

C T

S T

T W

A N

D R

B

A C

K E

S

P U

M P

H O

U S

E

S

T R

U C

T U

R A

L

D

E M

O L I T

I O

N

P

L A

N

SCALE: 1:50

0 1000 2000PUMPHOUSE 328 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD105 PH-SD105 SCALE: 1:50

SCALE: 1:50

0 1000 2000PUMPHOUSE 334 -FIRST FLOOR AND LOWER LEVEL - STRUCTURAL DEMO PLAN

PH-SD105 PH-SD105 SCALE: 1:50

020_PH-SD101
021_PH-SD102
022_PH-SD103
023_PH-SD104
024_PH-SD105