This solicitation package describes requirements for a renovation project at the Harry S. Truman Memorial Veterans Hospital in Columbia, Missouri. The scope of work involves renovating an existing 12,500 square foot pre-engineered metal building warehouse to add 3,800 square feet of mezzanine storage space and upgrading building systems. Architectural work includes exterior CMU and insulated metal panel extensions, interior demolition and new partitions, and finishes. Structural upgrades include raising the roof and adding interior and exterior stairs. Mechanical systems will be replaced with a new air handling unit and terminal boxes. Plumbing and electrical systems will be extended and upgraded. Technology revisions include recabling for data, access control, alarm, and surveillance systems. The estimated price range for completion is $2,000,000 to $5,000,000. As a total SDVOSB set-aside, proposals are due by May 7, 2021 with award utilizing LPTA and no discussions. The contract duration is up to 330 calendar days from notice to proceed.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FD
B
CDE
F
A
BULK/UNIT
STORAGE
W03
DRUG
CACHE/STORAGE
W03A
EQUIPMENT
PREP
STAGING
W05A
PROSTHETICS
STORAGE
W04
STERILE
CONSUMABLES
(SOFT
GOODS)
STORAGE
W05
PROSTHETICS
STORAGE
W04A
CORRIDOR
WC02
STORAGE
W06
VCS
STORAGE
W01
RECEIVING
DOCK
W02
CORRIDOR
WC01
RECEIVE/ISSUE
W10C
RECEIVE/ISSUE
W10A
SUPERVISOR
OFFICE
W09
BREAK
ROOM
W07
STAFF
TLT
W08
H
G
BLDG. 23 -
CHILLER
PLANT
BLDG. 14 -
WAREHOUSE
BLDG. 1 -
HOSPITAL
CONNECTING
CORRIDORI
K
J
L
MN
O
P Q
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 Fax: 402.291.9193
AH. INZ
Incandescence Life Safety, Inc.
3575 Ringsby Court, #408, Denver, CO, 80216
Phone:(720) 722-3010
589A4-20-158
IMEG Corp.
15 Sunnen Drive, Suite 104
St. Louis, MO 63143
Phone:(314) 951-2534
BID SET RENOVATE WAREHOUSE FOR
PANDEMIC PREPAREDNESS
HARRY S. TRUMAN MEM. VETERANS HOSPITAL
800 HOSPITAL DR., COLUMBIA MO 65201
BID SET 03/24/2021
Dwg. # of 94
C
L H
D C
\H o m e
\t fi e s e lm a n \R e v it M o d e ls \R
-2
-2
A
-2
-1
R e n o v a te W a re h o u s e tf ie s e lm a n A
G
Y .r v t
/2
/2
:4
:0
A
M
RA104
EXISTING CONDITIONS PLAN, EXT. &
INT. PHOTOS - CORRS. & OPEN AREA
AHT TJF03/24/2021
1/8" = 1'-0"1
EXISTING CONDITION FLOOR PLAN
NOT TO SCALEB
CORR WC01A - W10A WORK STATION
NOT TO SCALEC
CORR WC01A IN-FLOOR SCALE
NOT TO SCALED
CORR WC01A-W10B @ COPIER
NOT TO SCALEE
CORR WC01A / W10C
NOT TO SCALEF
CORR WC01A @ EW08-EW09 ALCOVE
NOT TO SCALEA
CORR WC01 LOOKING EAST
EXIST CONC FLOOR (TYP) - SEE FINISH
PLAN FOR NEW EPOXY FLOOR COATING
EXIST LIGHT - SEE ELEC LIGHTING PLAN FOR DISPOSITION
EXIST CMU WALL TO REMAIN (TYP)
EXIST WALL-MTD TACKBOARD TO REMAIN
EXIST FIRE EXTINGUISHER / WALL BRACKET - VERIFY LOCATION W/
COR - RELOCATE AS DIRECTED
EXIST DOOR WC01 W/ AUTOMATIC OPENER & ACCESS CONTROL
NOT TO SCALEH
EXT. WH N. ROOF-CHILLER LINES
NOT TO SCALEG
CORR CBG1 ROOF - CW AREAWAY
NOT TO SCALEI
RM. W01 LOOKING SOUTH
NOT TO SCALEK
RM. W01 N. WALL
NOT TO SCALEJ
RM. W01 E. WALL
NOT TO SCALEM
RM. W01 FIRE RISER-ENTRANCE
NOT TO SCALEN
RM. W01 SW CORNER-FIRE RISER
NOT TO SCALEO
CORR WC01-DOOR W01A
NOT TO SCALEP
RM. W10A ABOVE WDW.
NOT TO SCALEQ
CORR WC01A LOOKING WEST
NOT TO SCALEL
RM. W01 SE CORNER
REPLACE FIRE EXTINGUISHER WALL FLAG - SEE FINISH & SIGNAGE
DRAWINGS - VERIFY LOCATION W/ COR, LOCATE AS DIRECTED BY
COR
EXIST CONC FLOOR - SEE FINISH PLAN
FOR NEW EPOXY FLOOR COATING
EXIST LIGHT (TYP) - SEE ELEC LIGHTING PLAN FOR DISPOSITION
EXIST CMU WALL TO REMAIN (TYP)
EXIST WALL-MTD SIGNAGE TO BE REMOVED AS PART OF
DEMOLITION (TYP)
EXIST PLASTIC LAMINATE/PARTICLE BOARD COUNTERTOP TO
REMOVE AND REPLACE W/ SOLID SURFACE COUNTERTOP
SEE FINISH / SIGNAGE PLAN AND ELECT/TECH FOR LOCATION OF
NEW PUSH BUTTON/SIGNAGE FOR CONTROL OF DOOR WC01
EXIST WOOD-FRAMED WINDOWS AND GWB / FRAMED INFILL ABOVE
TO REMOVE AT WORK STATIONS (TYP) - TO BE REPLACED W/
GWB/METAL STUD INFILL W/ HM BORROW LITE/LAMINATED GLASS
EXIST IN-FLOOR SCALE TO BE REMOVED - PIT TO INFILL W/ CONC EXIST IN-FLOOR SCALE TO BE REMOVED - PIT TO INFILL W/ CONC
EXIST IN-FLOOR SCALE EQUIPMENT TO BE REMOVED
EXIST PHONE TO REMOVE/RELOCATE - SEE ELECT/TECH
EXIST SHELVING UNIT (TYP) TO BE REMOVED BY VA PRIOR TO
DEMOLITION
EXIST LIGHT (TYP) - SEE ELEC LIGHTING PLAN FOR DISPOSITION
EXIST COPIER TO BE RELOCATED BY VA PRIOR TO WORK IN AREA
EXIST FURNITURE, COMPUTER AND EQUIPMENT (TYP) TO BE
REMOVED BY VA PRIOR TO DEMOLITION
EXIST CONC FLOOR - SEE FINISH PLAN FOR
NEW EPOXY FLOOR COATING
EXIST CONC FLOOR - SEE FINISH PLAN
FOR NEW EPOXY FLOOR COATING
EXIST LIGHT (TYP) - SEE ELEC LIGHTING PLAN FOR DISPOSITION
EXIST CMU WALL TO REMAIN (TYP)
EXIST PLASTIC LAMINATE/PARTICLE BOARD COUNTERTOP TO
REMOVE AND REPLACE W/ SOLID SURFACE COUNTERTOP
EXIST WOOD-FRAMED WINDOWS AND GWB / FRAMED INFILL
ABOVE TO REMOVE AT WORK STATIONS (TYP) - TO BE
REPLACED W/ GWB/METAL STUD INFILL W/ HM BORROW
LITE/LAMINATED GLASS
EXIST FURNITURE, COMPUTER AND EQUIPMENT (TYP) TO BE
REMOVED BY VA PRIOR TO DEMOLITION
EXIST WALL-MOUNTED EQUIPMENT TO BE REMOVED BY GC PRIOR
TO WORK IN AREA - STORE AND REINSTALL AS DIRECTED BY COR
EXIST CONC FLOOR - SEE FINISH PLAN
FOR NEW EPOXY FLOOR COATING
EXIST WALL-MOUNTED EQUIPMENT TO BE REMOVED BY GC
PRIOR TO WORK IN AREA - STORE AND REINSTALL AS DIRECTED
BY COR (TYP)
EXIST WALL-MOUNTED TOILET ACCESSORIES IN STAFF TOILET W08
TO BE REMOVED BY GC PRIOR TO WORK IN AREA - STORE AND
REINSTALL AS DIRECTED BY COR IN NEW STAFF TOILET W08 (TYP)
EXIST ROOMS W07, W08 & W09 TO DEMO -
SEE PHASING AND DEMOLITION PLANS
EXIST SHELVING (TYP) TO BE REMOVED BY VA
PRIOR TO DEMOLITION
EXIST ROCK MULCH
EXIST GUTTER TO REMAIN
EXIST CONC WALL/CURB (TYP)
EXIST ASPHALT ROLLED ROOFING -
MATCH FOR NEW WORK FOR NEW AHU /
ROOF CURB INSTALLATION
EXIST A/C CONDENSER / REFRIGERANT
LINES TO REMOVE - SEE MECH
EXIST CHILLED WATER LINES FROM
CHILLER PLANT (TYP)
EXIST CHILLED WATER AREAWELL
W/ BAR GRATING COVER
EXIST GUTTER TO REMAIN EAST OF GRID
LINE 4 - SEE DEMO & RENO ROOF PLANS
EXIST DOWNSPOUT BOOT / CONNECTOR
TO REMAIN - SEE DEMO & RENO ROOF
PLANS FOR EXTENTS
EXIST DOWNSPOUT TO REMAIN EAST OF
GRID LINE 4 - SEE DEMO & RENO ROOF
PLANS FOR EXTENTS
EXIST CONC PIPE SUPPORT PIER / PIPE SUPPORTS (TYP)
EXIST BATTEN SEAM ROOF TO REMAIN EAST OF GRID LINE 4 -
SEE PHASING, DEMO & RENO ROOF PLANS
EXIST CHILLED WATER LINES FROM CHILLER PLANT (TYP) -
PROTECT DURING CONSTRUCTION - REVEIW METHODS OF
PROTECTION W/ COR FOR APPROVAL PRIOR TO START OF WORK
APPROXIMATE OUTLINE OF NEW CONSTRUCTION WEST OF
GRID LINE 4
EXIST BATTEN SEAM ROOF TO REMOVE WEST OF GRID LINE 4 -
SEE PHASING, DEMO & RENO ROOF PLANS
EXIST UNIT HEATER - SEE MECH FOR DISPOSITION
EXIST LIGHTING - SEE ELEC FOR DISPOSITION
EXIST FIRE SPRINKLER RISER - SEE FIRE SPRINKLER
DRAWINGS
EXIST ROOF FRAMING / INSULATION TO REMAIN
EXIST SHELVING TO BE RELOCATED BY VA PRIOR TO
START OF WORK IN ROOM - COORDINATE W/ COR
EXIST HIGH-DENSITY STORAGE SYSTEM TO REMAIN -
COORDINATE W/ COR FOR PLACEMENT OF
TEMPORARY CONSTRUCTION PARTITIONS IN ROOM
EXIST SHELVING (TYP) TO BE RELOCATED BY VA PRIOR TO
START OF WORK IN ROOM FOR EXTERIOR WALLS -
COORDINATE W/ COR
EXIST ELEC DISTRIBUTION PANELS (TYP) - SEE ELEC FOR DISPOSITION
EXIST ELEC EQUIPMENT (TYP) - SEE ELEC FOR DISPOSITION
EXIST DOOR W01 - HM DOOR W/ SIMPLEX CIPHER LOCK - DOOR TO
REMAIN AND MODIFY FOR NEW HW; EXIST SIMPLEX LOCK TO REMOVE
AND REPLACE WITH NEW LATCH ASSEMBLY AND ACCESS CONTROL /
SECURITY HARDWARE RELOCATED FROM DOOR W06. SEE DOOR - HW
SCHEDULES AND ELECT/TECH
EXIST DOOR W01 - HM DOOR FRAME - FRAME TO REMAIN AND MODIFY
FOR NEW ELEC STRIKE AND ACCESS CONTROL / SECURITY HARDWARE
RELOCATED FROM DOOR W06. SEE DOOR - HW SCHEDULES AND
ELECT/TECH
EXIST HIGH-DENSITY STORAGE SYSTEM TO REMAIN -
COORDINATE W/ COR FOR PLACEMENT OF TEMPORARY
CONSTRUCTION PARTITIONS IN ROOM
EXIST SHELVING TO BE RELOCATED BY VA PRIOR TO START OF
WORK IN ROOM - COORDINATE W/ COR
EXIST FIRE EXTINGUISHER (TYP) - SEE DRAWINGS FOR LOCATION
OF NEW WALL BRACKET AND SIGNAGE
EXIST DOOR W01A - SEE DOOR-& HW SCHEDULES FOR NEW HW
EXIST SHELVING TO BE RELOCATED BY VA PRIOR TO START OF
WORK IN ROOM FOR NEW ELEC PANELS, SPRAY-FOAM INSULATION,
FURRING AND METAL WALL PANELS AT EXTERIOR WALLS -
COORDINATE W/ COR
EXIST LIGHTING (TYP) - SEE ELEC FOR DISPOSITION
EXIST LIGHTING (TYP) - SEE ELEC FOR DISPOSITION
EXIST UNIT HEATER - SEE MECH FOR DISPOSITION
EXIST HIGH-DENSITY STORAGE SYSTEM REMAIN -
COORDINATE W/ COR FOR PLACEMENT OF TEMPORARY
CONSTRUCTION PARTITIONS IN ROOM
EXIST FIRE SPRINKLER RISER - SEE FIRE SPRINKLER DRAWINGS
EXIST BACKFLOW PREVENTER-
SEE FIRE SPRINKLER DRAWINGS
EXIST MAIN DRAIN LINE
EXIST WALL-MTD ELEC WIREMOLD TO RELOCATE FOR NEW
EXTERIOR WALL INSULATION / FURRING / METAL WALL LINER
PANEL INSTALLATION AT EXTERIOR WALLS - SEE ELECT
EXIST EXTERIOR CMU WALL - PREP FOR NEW EXTERIOR
WALL INSULATION / FURRING / METAL WALL LINER
PANEL INSTALLATION AT EXTERIOR WALLS
EXIST LIGHTING (TYP) - SEE ELEC FOR DISPOSITION
EXIST LINE TO FDC
CONNECTION - SEE FIRE
SPRINKLER DRAWINGS
EXIST DOOR W01A - SEE DOOR-& HW
SCHEDULES FOR NEW HW
EXIST LIGHTING (TYP) - SEE ELEC FOR DISPOSITION
EXIST DOOR WC01 - SEE DOOR -
HW SCHEDULES FOR NEW HW;
SEE ELECT/TECH FOR NEW
ACCESS CONTROL HW
EXIST LIGHT (TYP) - SEE ELEC LIGHTING PLAN FOR
DISPOSITION
EXIST CMU WALL TO REMAIN (TYP)
EXIST WOOD-FRAMED WINDOWS AND GWB / FRAMED
INFILL ABOVE TO REMOVE AT WORK STATIONS (TYP) -
TO BE REPLACED W/ GWB/METAL STUD INFILL W/ HM
BORROW LITE/LAMINATED GLASS
EXIST GWB / FRAMED INFILL ABOVE WINDOWS TO
REMOVE AT WORK STATIONS (TYP) - TO BE REPLACED
W/ GWB/METAL STUD INFILL W/ HM BORROW
LITE/LAMINATED GLASS
EXIST FIRE SPRINKLER LINE (TYP) -
SEE FIRE SUPPRESSION DRAWINGS
SEAL ALL PENETRATIONS THROUGH WALL (TYP) -
PROVIDE FIRE SEALANT / FIRE STOPPING WHERE REQ'D.
EXIST IN-FLOOR SCALE EQUIPMENT TO BE REMOVED
EXIST PHONE TO REMOVE/RELOCATE - SEE ELECT/TECH
EXIST SHELVING UNIT (TYP) TO BE REMOVED BY VA
PRIOR TO DEMOLITION
EXIST CMU ROOMS & CONC DECK TO REMOVE -
SEE PHASING & DEMO DRAWINGS
EXIST CONC FLOOR (TYP) - SEE FINISH PLAN
FOR NEW EPOXY FLOOR COATING
COORDINATE W/ COR FOR INSTALLATION OF
TEMPORARY CONSTRUCTION BARRIERS TO ALLOW FOR
WORK BY VA WAREHOUSE STAFF TO CONTINUE IN
AREA DURING CONSTRUCTION - SEE PHASING AND
DEMO PLANS
WORKSTATION W10A - AREA TO REMAIN
OCCUPIED BY VA DURING CONSTRUCTION
OVERHEAD CABLE TRAY, ELECT, DATA AND STEAM
LINES (TYP) - SEE MECH, ELEC AND TECH FOR
TEMPORARY RELOCATION DURING CONSTRUCTION