Z2DA--Renovate Warehouse for Pandemic Preparedness PN: 589A4-20-158
Solicitation number
36C25521R0075
Issued by

About this file

This solicitation package describes a renovation project for the Department of Veterans Affairs. The scope of work involves renovating an existing 12,500 square foot warehouse building in three phases to raise approximately 6,000 square feet of roof, add a 3,800 square foot mezzanine, and upgrade mechanical, electrical, and technology systems. Architectural work includes interior and exterior renovations. Structural work will construct the new mezzanine. Mechanical upgrades include a new air handling unit and zone terminal units. Electrical work includes new panelboards and lighting. Technology revisions involve recabling for category 6A, a new access control system, and security camera additions. The estimated price range is $2-5 million. As a total SDVOSB set-aside pursuant to Public Law 109-461, the solicitation will be available on April 2nd with proposals due May 7th. An organized site visit is scheduled.

View the file

Other files

File Type Posted
AD102 Amendment 3.pdf PDF
MD101 Amendment 3.pdf PDF
M-301 Amendment 3.pdf PDF
EL101 Amendment 3.pdf PDF
EP101 Amendment 3.pdf PDF
S-501 Amendment 3.pdf PDF
AF101 Amendment 3.pdf PDF
PD101 Amendment 3.pdf PDF
M-102 Amendment 3.pdf PDF
M-101 Amendment 3.pdf PDF
AE401 Amendment 3.pdf PDF
M-500 Amendment 3.pdf PDF
P-101 Amendment 3.pdf PDF
S-301 Amendment 3.pdf PDF
PH101 Amendment 3.pdf PDF
AF502 Amendment 3.pdf PDF
ED101 Amendment 3.pdf PDF
11 00 00 Beam Scale Cut Sheet - Amendment 3.pdf PDF
AC102 Amendment 3.pdf PDF
31 62 00 Driven or Drilled Micropiles - Amendment 3.pdf PDF
36C25521R0075 0003.docx DOCX document
01 35 26 pgs 12-13 - Amendment 3.pdf PDF
AD101 Amendment 3.pdf PDF
PH103 Amendment 3.pdf PDF
S-001 Amendment 3.pdf PDF
00 01 10 pg 4 - Amendment 3.pdf PDF
ATTENDANCE ROSTER.pdf PDF
36C25521R0075 0002.docx DOCX document
589A4-20-158 GeoTech Report.pdf PDF
36C25521R0075 0001.docx DOCX document
Drawings 589A4-20-158 VOL 3- 1 page.pdf PDF
36C25521R0075_1.docx DOCX document
Drawings -589A4-20-158 VOL 2- 2 pages.pdf PDF
Drawings-589A4-20-158 VOL 4-1 page.pdf PDF
S02-Specifications 589A4-20-158- Volume 1 -630 pages.pdf PDF
S02-Specifications 589A4-20-158 - Volume 2 Divs 21-48- 848 pages.pdf PDF
Drawings 589A4-20-158 VOL 1- 90 pages.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

A

B

C

D

F

G

E

1 2 3 4 5 6 7

'-8

2'-6" 22'-6" 2'-0" 21'-0" 2'-0" 23'-0" 2'-0" 25'-0" 25'-0" 25'-0" 11 15/16"

'-0

'-4

'-0

'-0

'-4

2'-6" 22'-6" 2'-0" 21'-0" 2'-0" 23'-0" 2'-0" 25'-0" 25'-0" 25'-0" 11 15/16"

AE201

AE201

AE201 2

AE2013

BULK

ITEMS

STORAGE

W03

PROSTHETICS

STORAGE

W04

STERILE

CONSUMABLES

(SOFT

GOODS)

STORAGE

W05

RECEIVING

BREAKOUT

INSPECTION

(NEW)

W06

CORRIDOR

WC03

VETERANS

CANTEEN

SERVICE

(VCS)

STORAGE

W01

CORRIDOR

CBC2CORRIDOR

WC01A

RECEIVING

DOCK

W02

LOGICAL

UNIT

OF

MEASURE

(LUM)

STAGING

ROOM

(NEW_

W05A

OIT

CLOSET

W05B

BULK

ITEMS

STORAGE

W03B

DRUG

CACHE-STORAGE

W03A

2.11.1 2.9

3.9

'-0

'-8

/4

1'-4"

C.6

B.4

1'-4"

AE301

AE301

5'-0" 12'-1" 8'-3 3/4" 19'-1 1/4" 6'-0"

EXISTING

36'-1 1/4" 13'-7 1/4"

EXISTING F.O. CMU-F.O. CMU

24'-10 7/8"

EXISTING

19'-3 1/8"55'-8 11/16"

E X

IS

T

IN

G

'-0

E

X

IS

T

IN

G '-0

V

E R

IF

Y

'-1

E X

IS

T

IN

G

'-8

4 1/4"

V E

R

IF

Y '-5

/4

VERIFY

6'-0 13/16"

E X

IS

T

IN

G

'-1

/2

E X

IS

T

IN

G

'-4

/8

EXIST ELEC

PANELS -

SEE ELECT

EXIST GWB OVER MTL STUD

FRAMING OVER CONC/CMU

E X

IS

T

IN

G

'-7

/8

'-8

/1

'-1

'-5

/1

INFILL OPENING W/ 6" CMU

NEW PR 3-0X7-0

HM DR/FR W/ 2"

HEAD

ULTRA LOW

FREEZER AREA

PHARMACY

REFRIGERATOR AREA

EXIST FDC SIAMESE

CONNECTION - SEE FIRE

EXIST HIGH-DENSITY

FILE STORAGE SYSTEM

NEW ELEC

PANELS -

SEE ELECT

EXIST

CONC

WALL

EXIST EXTERIOR

AREA WAY

EXIST CHILLED

WATER PLANT

BLDG 23

STAFF

TOILET

(NEW)

W08

SUPERVISOR

OFFICE

(NEW)

W09

AE303

AE302

AE302

AE401

C1

V E

R

IF

Y '-1

/8

V E

R

IF

Y '-0

CORRIDOR

CBG1

CORRIDOR

WC01

E X

IS

T

IN

G

V

E R

IF

Y

'-1

/4

6'x6' MIN. CLEAR SPACE

IN FRONT OF LIFT

W02A W02 W01A

W03B

W09

W08

W04

W01

WC01

W05

W05B

W05A

W04B

W02E W02D W02C

W02B

M6

M6 M6

M4

M4 M6

AE303

AE310

C8

E X

IS

T

IN

G

'-1

/8

AE503

C5

AE504

C4

AE901

C1

C6

77'-4 15/16"

W04A

STAFF

LOUNGE

(NEW)

W04A

STAIRS

WS02

CORRIDOR

WC02

MATERIAL

LIFT

LOBBY

W03C

RECEIVING/ISSUE

W10C

RECEIVING/ISSUE

W10B

RECEIVING/ISSUE

W10A

EQUIPMENT

PREP/

STAGING

(NEW)

W07

AE503 C3 C013

W10

CBG1

G00Y

G00X

23-01

23-02

S

Rb Ra

12.5

13.4

13.5

S.9

9.1

10.4

T

13.2

U

10.2

9.8

8.9

DD CC.6 CC BB AA Z Y U.5VWW.3W.4X

11.5

F3 F2A

F2A

F2A

F3

F3

F3A

F2A

AE311

F1

AE311

F5

AE311

F3

AE311

F7

F2A

F1

CORRIDOR

CBC2

CG-3

CG-1

CG-1

CG-1

CG-1

CG-2

CG-3 CG-3

CG-3

CG-3CG-3

A1

A1

W03A

GALV STL EXTERIOR

STAIRS / LANDINGS (PH 3)

SHEET

METAL

SHOP

C013A

SHEET

METAL

SHOP

C013

CORRIDOR

G012

CORRIDOR

CBG2

MECHANICAL

ROOM

G001

ELECT

ROOM

G013

CLEAN

RECEIVING

BREAKOUT

G048

BULK

STORAGE

G047HALL

G046

STORAGE

W10

RELIEF

AIR

AREAWAY

G00Y

CHILLED

WATER/PIPING

AREAWAY

G00X

UNEXCAVATED

UNEX

FRESH

AIR

AREAWAY

G001A

CHASE

C00Z

CORRIDOR

CBG1A

CORRIDOR

CBG1B

1 HR FIRE BARRIER

VERT. OPQ (SHAFT)

FIRE BARRIER

EXIST

SEWER

MANHOLE

EXIST

CONC

WALK

NEW CONC

LANDING /

WALK

EXIST CONC

PIPE SUPPORT

(TYP)

AE310

F7

STAIR

WS01

MAT'L

LIFT

WE01

734.55 734.50733.48

732.38728.48723.06

723.51

726.99

731.10

733.85

CO

721.39 721.06

719.64719.27721.21722.59

722.71

722.47 721.12

719.65

721.89

723.07

723.15

722.40

721.23

722.82723.85

723.44

723.65 DS DS

719.63

719.26 PIV

719.38

719.22

722.96

719.80 719.69 719.76

719.50

721.90

719.34

719.93

719.34

FH

WV

CO W/

STL CVR

723.26

724.00 725.00 726.00 728.00 729.00 730.00 732.00 733.00 734.00 735.00

735.00734.00733.00

733.00

734.00

732.00

732.00

731.00730.00729.00728.00726.00 727.00725.00

725.00

724.00

723.25

723.00

DS

720.00

719.29

722.72

AE502

D1

MECHANICAL

ROOM

C012

MECHANICAL

ROOM

C011

F E

FE

F1

CG-2 CG-2

CG-2

CG-2CG-2

ECJ

ECJ

ECJ

ECJ

FE

AE902 F3

D1

D3

F1

F6

DS

AE503

F1

DS

DS DS

DS

24'-6 1/8"

CORRIDOR

WC04

CG-1

CG-3

730.2

EXIST

CHILLER

EXIST

CHILLER

AE902

B5

B3

AE904

C5

C3

C1

C7

LADDER

AE904 B3

B1

B8

B6

AE903

F1

F3

F5

F7

AE903

B1

B4C1

B7

AE904

F1

E1

E5E7

FORKLIFT CHARGING STATION

CORRIDOR

CBG1

W06

AE904

F4

F8

F3 F3

F3

F3

F2

NARCOTICS

STORAGE

CAGE

W03A1

F2A

F3

F3

CG-3

CG-3

F2A F2A

CG-3

CG-3CG-3CG-3

FEC

CG-3

CG-3

CG-3

CG-3

CG-3

CG-3CG-3CG-3CG-3

CG-3

CG-1

FEC

AE310

F9

'-0

/8

1'-0 1/2"

F1 F1

F3 F3 F3

INFILL W/ GWB/

MTL STUDS -

FINISH TO

MATCH EXIST

AE401

D2

CG-1 CG-1

DESK COPIER

A A

W2 9

FE

INFILL

OPENING W/

6" CMU

INFILL OPENING

W/ 6" CMU10

W1 W1

G012

G013

G001A

G048

G046A

G047A G047

CBG1B

G001B

DS

G

W

W

W W

S S

S S

S S

S S

S S

S S

SSS

S

SS SS

SS

W

S S

S

S

SS

W W W

W

SS

CW

CW

C W

SS

SS SSW

W

W

W

W

S

S

UGE

UGE UGE UGESS

UGE

UGE

UGE

S

S

S

S

SS

SS SS

S S

S S

S S

W

CO

CO

UGE

W03A1

FE

EXIST EMERG SHWR / EYE WASH

B1

B7

AE502

E8

DEMO/CAP

PORTION OF

ABANDONED UGE

OUTSIDE OF

BLDG - SEE ELECT

INTRUSION

ALARM

PANEL

ACCESS CONTROL

KEYPAD-CARD READER

EXIST MARKER BOARD

SHADED AREA NOT IN SCOPE OF WORK

SHADED

AREA

NOT IN

SCOPE

OF

WORK

SHADED

AREA NOT

IN SCOPE

OF WORK

DS

DS

PHASING GENERAL NOTES:

PHASING TO BE DEVELOPED TO MINIMIZE DISRUPTION OF

OWNER-RELATED ACTIVITIES WITHIN THE PROJECT AREA.

REFER TO PHASING PLANS PH101 THRU PH103 FOR

ADDITIONAL INFORMATION.

BRIEF PHASING DESCRIPTION:

A. PHASE 1 - DEMOLITION AND INSTALLATION OF WEST

WAREHOUSE NEW ROOF SUPERSTRUCTURE,

MODIFICATION OF EXISTING EAST WAREHOUSE ROOF

AND BUILDING STRUCTURE; LIMITED DEMOLITION

EAST WAREHOUSE OF INTERIOR ROOMS W07-W08-

W09; CONSTRUCT HVAC FROM BLDG. 1 TO

WAREHOUSE.

B. PHASE 2 - DEMOLITION OF WEST WAREHOUSE

EXISTING ROOF/FRAMING, CONSTRUCTION OF WEST

WAREHOUSE UPPER EXTERIOR WALL ENCLOSURE;

LIMITED DEMOLITION OF WEST WAREHOUSE INTERIOR

ROOM W03A.

C. PHASE 3 - CONSTRUCTION OF NEW MEZZANINE

FLOOR AND DRUG STORAGE ROOM W03A;

CONSTRUCTION OF NEW OFFICE/TOILET W08-W09;

NEW EXTERIOR WALL INSULATION AND FINISHES.

PHASING NOTES:

FLOOR PLAN SHEET NOTES:

1. NEW FLOOR SCALE. LOCATE PER COR DIRECTION.

2. NEW STEEL STAIRS. SEE SHEET AE502 FOR DETAILS. SEE

SECTION 055100 FOR DELEGATED DESIGN REQUIREMENTS.

3. NEW MATERIAL LIFT. SEE SECTION 142411.

4. NEW SAFETY RAILING. SEE SECTION 055217.

5. NEW MEZZANINE SAFETY GATE ASSEMBLY. SEE SECTION

134413.

6. SEE DEDUCT ALTERNATES FOR FINISHES TO BE REMOVED

FROM THIS ROOM.

7. SEE DEDUCT ALTERNATES FOR ITEMS TO BE REMOVED FROM

THE WORK.

8. EXIST 180 DEG. REFLECTOR TO REMAIN.

9. INSTALL SALVAGED MB 24x36 FROM W09.

10. SALVAGED REFRIGERATOR BY VA.

11. NEW KEYPAD / CARD READER + INTRUSION ALARM PANEL FOR

W01 - DUAL AUTHENTICATION.

12. EXIST TABLE TO REMAIN.

13. REINSTALL SALVAGED 40" x 24" DISPLAY BOARD AND CLOCK.

14. ICE / WATER DISPENSER - VA PROVIDED-CONTR. INSTALLED

(VC). SEE MECHANICAL DRAWINGS FOR WORK RELATED TO

LOCATION AND INSTALLATION OF VA-PROVIDED ICE & WATER

DISPENSER. IF BID ITEM #2 FOR DELETION OF NEW ROOMS

W08 AND W09 IS ACCEPTED, ICE & WATER DISPENSER IS TO

BE DELETED.

15. EXIST - 48" DEEP PALLET RACKS AGAINST WALLS. RELOCATE

FOR NEW DOOR.

16. NEW PR 3'-0" x 7'-0" HM DR / FR W/ 4" MASONRY HEAD.

17. SALVAGED EXIST TABLE.

18. REUSE SALVAGED CLOCK, 36" x 48" MB, MW STAND w/ MW AND

TABLE.

19. REINSTALL EXIST METAL LOCKERS FROM W07.

20. EXIST GWB / MTL. STUD WALL - EXIST CONST. 3 5/8" MTL. STUD,

1 LAYER GWB EA. SIDE

21. 4" DIA. SCHEDULE 80 PIPE BOLLARD - SET IN 4'-DEEP X 16" DIA.

CONC FOOTING; FILL BOLLARD W/ LEAN CONC & MOUND TOP;

PAINT BOLLARD SAFETY YELLOW.

22. EXIST MTL STUD WALL REMAINS (PH 1); PARTIALLY DEMOLISH

TOP OF WALL FOR EXIST ROOF REMOVAL w/ TEMPORARY

EXTENSION TO NEW ROOF (PH 2); DEMO EXIST/TEMP WALL &

REPLACE w/ NEW WALL FOR NEW UPPER FLOOR & PHYSICAL

SECURITY REQ'TS (PH 3).

23. 48" DEEP PALLET RACKS AGAINST WALL (V V).

24. DEMO EXIST GWB OVER MTL STUD FRAMING FOR NEW

STRUCT X-BRACE; REPLACE w/ NEW INSUL/FURR/GWB (PH 2).

25. DEMO EXIST GWB OVER MTL STUD FURRING OVER CMU;

INSTALL NEW INSUL/FURR/GWB (PH 2).

26. INFILL w/ CMU TO MATCH EXIST.

27. SEE MEP DRAWINGS FOR WORK OUTSIDE OF WAREHOUSE.

28. 48" DEEP PALLET RACKS AGAINST WALL (V V).

29. NEW CROSS BRACING - SEE STRUCT.

30. EXITING NARCOTICS STORAGE - WIRE CAGE 12'-6" W x 8'-4 1/2" D x 8'-6" H. CONTR TO REINSTALL AFTER NEW FLOORING IN

PLACE.

31. WIRE CAGE LIFT ENCLOSURE w/ DOUBLE VERT. LIFT GATES TO

+ 8'-0" ABOVE MEZZ. FLOOR BY LEFT MTG'T.

32. WIRE CAGE ENCLOSURE w/ GATE TO B.O. STRUCT. BY

CONTRACTOR.

33. NEW FLOOR SCALE (CC). SEE PHASING PLANS FOR

TEMPORARY LOCATION IN ROOM WO7 DURING

CONSTRUCTION.

34. NEW GWB OVER MTL. STUD FRAMING / INSUL. OVER

CONC./CMU.

35. 36" DEEP PALLETS RACKS (X2) w/ 6'-0" W AISLES (V V).

36. ADD INTRUSION SYSTEM FOR CANETTEN STORAGE - SEE ELEC

/ TECH.

37. NEW FIRE EXTINGUISHER / WALL BRACKET. BRACKET INSTALL

BY CONTR.

38. NEW FIRE EXTINGUISHER CABINET (CC).

39. ACCESS CONTROL KEYPAD-CARD READER. SEE ELEC / TECH.

40. INTRUSION ALARM PANEL. SEE ELEC / TECH.

41. EXTEND EXISTING GWB PARTITIONS FOR OIT CLOSET UP TO

BOTTOM OF STRUCTURE. MATCH EXISTING PARTITION

CONSTRUCTION. SEAL ALL THROUGH-WALL PENETRATIONS

AND TOPS OF WALLS PER REQ'TS. FOR 1-HOUR-RATED WALL

CONSTRUCTION.

FLOOR PLAN-

RENOVATION

SHEET NOTES:

FLOOR PLAN-RENO GENERAL NOTES:

1. REFER TO "GENERAL NOTES" ON SHEET G-002 FOR NEW

CONSTRUCTION GENERAL NOTES.

2. SEE "TEMPORARY BARRIERS & ENCLOSURES" ON SHEET G-002 FOR

TEMPORARY ENCLOSURE REQUIREMENTS DURING DEMOLITION

AND CONSTRUCTION.

3. SEE PH-SERIES SHEETS / PHASING PLANS FOR NOTES AND

INFORMATION RELATED TO TEMPORARY INTERIOR CONSTRUCTION

PARTITIONS AND OVERHEAD PROTECTION DURING CONSTRUCTION.

4. SEE RA-SERIES SHEETS FOR EXISTING CONDITIONS DRAWINGS AND

PHOTOS.

5. PALLET RACKING AND SHELVING TO BE VA-PROVIDED / VA-

INSTALLED (VV) UNLESS NOTED OTHERWISE.

6. CONTRACTOR TO INSTALL VA-PROVIDED EQUIPMENT AND TOILET

ACCESSOERIES NOTED AS 'VC'. SEE EQUIPMENT SCHEDULES.

FLOOR PLAN-

RENOVATION

GENERAL NOTES:

BLDG 14 -

WAREHOUSE

KEY PLAN

AREA 'G'

AREA 'C' AREA 'D'

AREA 'B' AREA 'A'

AREA 'E'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Incandescence Life Safety, Inc.

3575 Ringsby Court, #408, Denver, CO, 80216

Phone:(720) 722-3010

589A4-20-158

IMEG Corp.

15 Sunnen Drive, Suite 104

St. Louis, MO 63143

Phone:(314) 951-2534

BID SET RENOVATE WAREHOUSE FOR

PANDEMIC PREPAREDNESS

HARRY S. TRUMAN MEM. VETERANS HOSPITAL

800 HOSPITAL DR., COLUMBIA MO 65201

Dwg. # of 94

C

L H

D C

\H o m e

\t fi e s e lm a n \R e v it M o d e ls \R

-2

-2

A

-2

-1

R e n o v a te W a re h o u s e tf ie s e lm a n A

G

Y .r v t

/6

/2

:0

:1

P M

AE101

FLOOR PLAN - RENOVATION

AHT TJF03/24/2021

N O R

HT

1/8" = 1'-0"1

FLOOR PLAN

X

ACCESS CONTROL - CHANGE OUT EXIST

CARD READER TO KEYPAD-CARD READER

2424Revisions: Date:

Amendment 3 5-7-21

Sheets
AE101 - FLOOR PLAN - RENOVATION