M-102 Amendment 3.pdf

PDF 284 KB Posted

Attached to
Z2DA--Renovate Warehouse for Pandemic Preparedness PN: 589A4-20-158
Solicitation number
36C25521R0075
Issued by

About this file

This document outlines a federal contract opportunity to renovate a warehouse for pandemic preparedness at a Veterans Affairs medical center. The scope of work involves renovating an existing 12,500 square foot warehouse over three phases, including raising approximately 6,000 square feet of roof, adding 3,800 square feet of mezzanine storage, and interior renovations. Architectural, structural, fire protection, mechanical, electrical, plumbing, and technology work are detailed. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses and has an estimated value between $2-5 million. Interested parties can access the solicitation package on April 2nd with proposals due on May 7th. The award will be made using Best Value Lowest Price Technical Acceptable and is planned without discussions. All relevant registration, monitoring of amendments, and single site visit instructions are provided.

View the file

Other files

File Type Posted
AD102 Amendment 3.pdf PDF
MD101 Amendment 3.pdf PDF
M-301 Amendment 3.pdf PDF
EL101 Amendment 3.pdf PDF
EP101 Amendment 3.pdf PDF
S-501 Amendment 3.pdf PDF
AF101 Amendment 3.pdf PDF
PD101 Amendment 3.pdf PDF
M-101 Amendment 3.pdf PDF
AE101 Amendment 3.pdf PDF
AE401 Amendment 3.pdf PDF
M-500 Amendment 3.pdf PDF
P-101 Amendment 3.pdf PDF
S-301 Amendment 3.pdf PDF
PH101 Amendment 3.pdf PDF
AF502 Amendment 3.pdf PDF
ED101 Amendment 3.pdf PDF
11 00 00 Beam Scale Cut Sheet - Amendment 3.pdf PDF
AC102 Amendment 3.pdf PDF
31 62 00 Driven or Drilled Micropiles - Amendment 3.pdf PDF
36C25521R0075 0003.docx DOCX document
01 35 26 pgs 12-13 - Amendment 3.pdf PDF
AD101 Amendment 3.pdf PDF
PH103 Amendment 3.pdf PDF
S-001 Amendment 3.pdf PDF
00 01 10 pg 4 - Amendment 3.pdf PDF
ATTENDANCE ROSTER.pdf PDF
36C25521R0075 0002.docx DOCX document
589A4-20-158 GeoTech Report.pdf PDF
36C25521R0075 0001.docx DOCX document
Drawings 589A4-20-158 VOL 3- 1 page.pdf PDF
36C25521R0075_1.docx DOCX document
Drawings -589A4-20-158 VOL 2- 2 pages.pdf PDF
Drawings-589A4-20-158 VOL 4-1 page.pdf PDF
S02-Specifications 589A4-20-158- Volume 1 -630 pages.pdf PDF
S02-Specifications 589A4-20-158 - Volume 2 Divs 21-48- 848 pages.pdf PDF
Drawings 589A4-20-158 VOL 1- 90 pages.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T A

B

C

D

F

G

E

1 2 3 4 5 6 72.11.1 2.9 3.9

C.6

B.4

12.5

13.4 13.5

S.9

10.4

TU

10.2

9.8

CC.6 CC BB AA Z Y U.5VWW.3W.4X

11.5

PANDEMIC STORAGE

W11

STAIR

WS11

MAT'L LIFT

WE01

24x16

30x20 SA DN

Ø12 SA DN

TO 14-VAV-10

18x12 SA DN PROVIDE SECURITY

BARS AT FLOOR PENETRATION.

W03A-TU-11

W11-TU-12

16x24

WHSE-EF1

18" CWS DN

18" CWR DN

16x24

18x12

W11-TU-12

3/4" HWS&R DN TO 14-VAV-10.

1" HWR DN

1" HWS DN

1 1/4" HWS DN

1 1/4" HWR DN

1"HWR

1"HWS

24x16

18"CWS

18"CWR

x

1 1/4" HWR

1 1/4" HWS

3" CWR

3" CWS

48x24

2" LPS

SD-63

12x8/325

(TYP.8)

24x16 x

24x16

WHSE-AHU-1

W03-TU-13

18x12

48x24 RA DN

PROVIDE NEW EXHUAST

FAN IN PHASE 3.

MOUNT THE NEW FAN

ON THE EXISTING CURB

NEW WORK TO BE

COMPLETED IN PHASE 2.

NEW WORK TO BE

COMPLETED IN PHASE 2.

R D

KEEP DUCTWORK TIGHT TO

STRUCTURE. MINIMUM

CLEAR SPACE 10'-6" BELOW

DUCTWORK.

1 1/4"HWR

1 1/4"HWS

24x16

SG-63

14x6/260

(TYP.5)

18x12

REFER TO M-101

FOR CONTINUATION

MOUNT AIR HANDLING UNIT ON 14"

TALL ROOF CURB (MINIMUM) FOR COIL

PULLS AND MAINTENANCE ACCESS TO

ABOVE GRATED AREAWAY ELEVATION.

TEMPORARY LOCATION FOR

RELOCATED HEAT PUMP. EXTEND

REFRIGERANT PIPING TO THIS

LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Incandescence Life Safety, Inc.

3575 Ringsby Court, #408, Denver, CO, 80216

Phone:(720) 722-3010

589A4-20-158

IMEG Corp.

15 Sunnen Drive, Suite 104

St. Louis, MO 63143

Phone:(314) 951-2534

BID SET RENOVATE WAREHOUSE FOR

PANDEMIC PREPAREDNESS

HARRY S. TRUMAN MEM. VETERANS HOSPITAL

800 HOSPITAL DR., COLUMBIA MO 65201

Dwg. # of 94

C R e v it L o c a l F ile s \M

E P

T

.1

V A

T ru m a n W a re h o u s e

C

R u s s e ll.

J .A rn e s o n

.r v t

/2

/2

:0

:4

P

M

M-102

MEZZANINE FLOOR PLAN -

MECHANICAL

JASSNE ANUSHA03/24/2021

N O R

HT

1/8" = 1'-0"

MEZZANINE FLOOR PLAN - MECHANICAL

SHEET NOTES:

1. REFER TO ARCHITECTURAL PHASING

DRAWINGS PH101, PH102, AND PH103 FOR

ADDITIONAL INFORMATION.

Revisions: Date:

BID SET 03/24/2021

ADDENDUM NO. 1 4/29/2021

atast Text Box

AMENDMENT #3

atast Text Box 05/07/2021 atast Snapshot

File details come from the government source that posted it. Updated .