AF101 Amendment 3.pdf

PDF 305 KB Posted

Attached to
Z2DA--Renovate Warehouse for Pandemic Preparedness PN: 589A4-20-158
Solicitation number
36C25521R0075
Issued by

About this file

This solicitation package seeks proposals for the renovation of a warehouse at the Harry S. Truman Memorial Veterans Hospital in Columbia, Missouri. The scope of work includes raising approximately 6,000 square feet of roof, adding 3,800 square feet of mezzanine storage space, interior renovations, upgrading building systems to current energy codes and HVAC standards, and rebuilding a 1,500 square drug storage room. Proposals are due by May 7, 2021. Award will be made using Best Value Lowest Price Technically Acceptable procedures to a Service-Disabled Veteran-Owned Small Business set-aside contractor. The work is to be completed within 330 calendar days of notice to proceed. Interested offerors are encouraged to attend an organized site visit.

View the file

Other files

File Type Posted
AD102 Amendment 3.pdf PDF
MD101 Amendment 3.pdf PDF
M-301 Amendment 3.pdf PDF
EL101 Amendment 3.pdf PDF
EP101 Amendment 3.pdf PDF
S-501 Amendment 3.pdf PDF
PD101 Amendment 3.pdf PDF
M-102 Amendment 3.pdf PDF
M-101 Amendment 3.pdf PDF
AE101 Amendment 3.pdf PDF
AE401 Amendment 3.pdf PDF
M-500 Amendment 3.pdf PDF
P-101 Amendment 3.pdf PDF
S-301 Amendment 3.pdf PDF
PH101 Amendment 3.pdf PDF
AF502 Amendment 3.pdf PDF
ED101 Amendment 3.pdf PDF
11 00 00 Beam Scale Cut Sheet - Amendment 3.pdf PDF
AC102 Amendment 3.pdf PDF
31 62 00 Driven or Drilled Micropiles - Amendment 3.pdf PDF
36C25521R0075 0003.docx DOCX document
01 35 26 pgs 12-13 - Amendment 3.pdf PDF
AD101 Amendment 3.pdf PDF
PH103 Amendment 3.pdf PDF
S-001 Amendment 3.pdf PDF
00 01 10 pg 4 - Amendment 3.pdf PDF
ATTENDANCE ROSTER.pdf PDF
36C25521R0075 0002.docx DOCX document
589A4-20-158 GeoTech Report.pdf PDF
36C25521R0075 0001.docx DOCX document
Drawings 589A4-20-158 VOL 3- 1 page.pdf PDF
36C25521R0075_1.docx DOCX document
Drawings -589A4-20-158 VOL 2- 2 pages.pdf PDF
Drawings-589A4-20-158 VOL 4-1 page.pdf PDF
S02-Specifications 589A4-20-158- Volume 1 -630 pages.pdf PDF
S02-Specifications 589A4-20-158 - Volume 2 Divs 21-48- 848 pages.pdf PDF
Drawings 589A4-20-158 VOL 1- 90 pages.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

F

G

E

1 2 3 4 5 6 7 2.11.1

2.9 3.9

C.6

B.4

AE401

C5

STAFF

TOILET

(NEW)

W08

SUPERVISOR

OFFICE

(NEW)

W09

PROSTHETICS

STORAGE

W04

LOGICAL

UNIT

OF

MEASURE

(LUM)

STAGING

ROOM

(NEW_

W05A

STERILE

CONSUMABLES

(SOFT

GOODS)

STORAGE

W05

RECEIVING

BREAKOUT

INSPECTION

(NEW)

W06

BULK

ITEMS

STORAGE

W03

DRUG

CACHE-STORAGE

W03A

RECEIVING

DOCK

W02

EQUIPMENT

PREP/

STAGING

(NEW)

W07

RECEIVING/ISSUE

W10C

RECEIVING/ISSUE

W10B

RECEIVING/ISSUE

W10A

CORRIDOR

WC01

VETERANS

CANTEEN

SERVICE

(VCS)

STORAGE

W01

CORRIDOR

WC02

CORRIDOR

WC03

CORRIDOR

WC04

MATERIAL

LIFT

LOBBY

W03C

STAIR

WS01

BULK

ITEMS

STORAGE

W03B

NARCOTICS

STORAGE

CAGE

W03A1

RES-2

EP

EP

EX

EP

EX

(SC)

EP

EX

(SC)

EP

EX (SC)

EX

(SC)

EP

RSF-1

EP

EP LVT

PT EP

EP EX (SC)

EP EX

W03B

W04A

W09

W04

W08

W06

W05B

W05

W05AW04B

W03A

W03A1

W02B

W02

W01A

WC01

W01W02A

WE01A

CG-3

CG-1 CG-3 CG-3

CG-3

CG-3

CG-3

CG-3

CG-3CG-3

CG-3

CG-3

CG-3

CG-3

CG-3

CG-1 CG-1 CG-1CG-1CG-1 CG-1

CG-3

CG-3CG-3 CG-3

CG-3

6 5

CG-3

CG-3

24 2322

24.5

OPEN BAR

GRATE STAIRS

BR-1/CR-1 BR-1/CR-1

BR-1/CR-1

BR-1/CR-1

BR-1/CR-1

BR-1/CR-1

BR-1/CR-1

BR-1/CR-1

BR-1/CR-1

MAT'L LIFT ENCLOSURE

4 1

'-0

21'-4 5/8" 10'-7 3/4" 7'-5 1/2" 6'-0"

'-0

MIN.

3'-0"

INTERIOR FINISH

PLAN LEGEND

LVT-1

RSF-1

PT-1

EXISTING FLOOR

FINISH TO REMAIN

EP- EPOXY PAINT

w/ NON-SLIP

AGGREGATE

SC-1 - SEALED

CONCRETE W/

COLORED

HARDENER

SEE COLOR SCHEDULE FOR FINISH CODES

SEE ROOM FINISH SCHEDULE FOR FINISHES

NOT IDENTIFIED ON PLAN

RES-2

SIGNAGE - SEE SIGNAGE

SCHEDULE & DETAILS

X

CG, CORNER GUARD

BUMPER / CRASH RAIL

BID ITEMS & DEDUCT ALTS:

REFER TO SECTION 01 00 00 FOR STATEMENT OF BID ITEMS

A. BID ITEM #1, GENERAL CONSTRUCTION: BASE BID: Renovate Warehouse for Pandemic Preparedness: Includes all scope communicated in the drawings and specifications.

1. Work includes general construction, alterations, walks, grading, drainage, necessary removal of existing structures and construction of certain other items.

B. BID ITEM #2, Renovate Warehouse for Pandemic Preparedness:

Includes all scope described in Bid Item #1 – excluding Bid Deduct #1 described below:

1. Work associated with new Material Lift WE01.

2. Work associated with construction and finishes for new

Rooms W08 and W09 (Demolition of existing Rooms W07, W08 and W09, including plumbing, fixtures and finishes in Room W08 will be retained in Base Bid);

3. Work associated with installation of new ceilings and f inishes in Rooms W04, W05A and W06;

4. Demolition and renovation of work counters at Rooms W10A and W10C.

BID ITEMS & DEDUCT

ALTERNATES:

SHEET NOTES - FINISH PLAN:

1. 2"-WIDE YELLOW/BLACK FLOOR STRIPING TAPE TO DENOTE

AREA TO BE KEPT CLEAR IN FRONT OF FIRE EXIT AND

STAIRS.

2. 2"-WIDE ORANGE FLOOR STRIPING TAPE TO DENOTE AREA

TO BE KEPT 3'-0" CLEAR IN FRONT OF ELECTRICAL

EQUIPMENT.

3. 2"-WIDE YELLOW/BLACK FLOOR STRIPING TAPE TO DENOTE

AREAS FOR OPEN AREA STORAGE / AISLEWAYS TO BE KEPT

CLEAR.

4. 2"-WIDE YELLOW/BLACK FLOOR STRIPING TAPE TO DENOTE

AREAS TO BE KEPT CLEAR IN FRONT OF MATERIAL LIFT.

5. 2"-WIDE YELLOW/BLACK FLOOR STRIPING TAPE TO DENOTE

AREA TO BE KEPT CLEAR IN FRONT OF CANTILEVERED

SAFETY GATE.

6. 2"-WIDE YELLOW/BLACK FLOOR STRIPING TAPE TO DENOTE

AREA TO BE KEPT CLEAR IN FRONT OF MATERIAL LIFT

EQUIPMENT DOOR.

7. BUMPER RAIL/CRASH RAIL - IF BID ITEM #2 ACCEPTED,

INSTALL BR-1/CR-1 BETWEEN DOORS W04 AND W04A.

FINISH PLAN

SHEET NOTES: X

GENERAL NOTES - FINISH PLAN:

1. REFER TO G-002 FOR GENERAL ARCHITECTURAL NOTES.

2. SEE SHEET AF501 FOR FLOOR TRANSITION DETAILS.

3. SEE SHEET AE502 FOR SIGN MOUNTING HEIGHTS AND

LOCATIONS.

4. SEE SHEET AE601 FOR COLOR SCHEDULE AND ROOM

FINISH SCHEDULE.

5. FLOOR STRIPING SHOWN TO BE 2"-WIDE SELF-ADHESIVE

TAPE. COORDINATE W/ COR FOR FACILITY STANDARD.

6. CONTR. TO COORDINATE W/ COR FOR FINAL COLORS

LOCATIONS AND LAYOUTS OF FLOOR STRIPING.

7. REFER TO "BID ITEMS AND DEDUCT ALTERNATES" ON

SHEET G-002 FOR DESCRIPTION OF BASE BID AND BID ITEM

DESCRIPTIONS.

GENERAL NOTES

FINISH PLAN:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Calvin rchitects, P.C.L 3705 North 200th Street

Elkhorn, Nebraska 68022

Phone: 402.291.6941 Fax: 402.291.9193

AH. INZ

Incandescence Life Safety, Inc.

3575 Ringsby Court, #408, Denver, CO, 80216

Phone:(720) 722-3010

589A4-20-158

IMEG Corp.

15 Sunnen Drive, Suite 104

St. Louis, MO 63143

Phone:(314) 951-2534

BID SET RENOVATE WAREHOUSE FOR

PANDEMIC PREPAREDNESS

HARRY S. TRUMAN MEM. VETERANS HOSPITAL

800 HOSPITAL DR., COLUMBIA MO 65201

Dwg. # of 94

C

L H

D C

\H o m e

\t fi e s e lm a n \R e v it M o d e ls \R

-2

-2

A

-2

-1

R e n o v a te W a re h o u s e tf ie s e lm a n A

G

Y .r v t

/6

/2

:0

:4

P M

AF101

FIRST FLOOR FINISH & SIGNAGE PLAN

AHT TJF03/24/2021

N O R

HT

1/8" = 1'-0"1

FINISH & SIGNAGE PLAN

47Revisions: Date:

Amendment 3 5-7-21

Sheets
AF101 - FIRST FLOOR FINISH & SIGNAGE PLAN