Drawings -589A4-20-158 VOL 2- 2 pages.pdf
PDF 18 MB Posted
- Solicitation number
- 36C25521R0075
About this file
This solicitation package describes requirements for a construction project to renovate an existing warehouse building for pandemic preparedness. Scope of work includes raising approximately 6,000 square feet of roof, adding 3,800 square feet of mezzanine storage, and interior renovations to upgrade building systems and accommodate controlled substance storage. Estimated cost is between $2-5 million. The solicitation and drawings will be available on or about April 2, 2021, with proposals due on or about May 7, 2021. Award will be made using best value low price technically acceptable source selection to a service-disabled veteran-owned small business set-aside. The North American Industry Classification Code is 236220 and small business size standard is $39.5 million. Project duration is up to 330 calendar days from notice to proceed.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FD
I H G F E
J
D
C
B
BLDG. 23 -
CHILLER
PLANT
BLDG. 14 -
WAREHOUSE
A
PROSTHETICS
STORAGE
W04
EQUIPMENT
PREP
STAGING
W05A
STERILE
CONSUMABLES
(SOFT
GOODS)
STORAGE
W05
BULK/UNIT
STORAGE
W03
DRUG
CACHE/STORAGE
W03A
PROSTHETICS
STORAGE
W04A
VCS
STORAGE
W01
RECEIVING
DOCK
W02
STORAGE
W06
CORRIDOR
WC02
BREAK
ROOM
W07
SUPERVISOR
OFFICE
W09
STAFF
TLT
W08
RECEIVE/ISSUE
W10C
RECEIVE/ISSUE
W10B
RECEIVE/ISSUE
W10A
CORRIDOR
WC01A
CORRIDOR
WC01
K
BLDG. 1 -
HOSPITAL
CONNECTING
CORRIDOR
CONC CHILLED
WATER PIPING
SUPPORT PIER
(TYP)
EXISTING CHILLED
WATER AREA WELL
EXISTING AREA
WELL
L
Q
O
N P
M
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 Fax: 402.291.9193
AH. INZ
Incandescence Life Safety, Inc.
3575 Ringsby Court, #408, Denver, CO, 80216
Phone:(720) 722-3010
589A4-20-158
IMEG Corp.
15 Sunnen Drive, Suite 104
St. Louis, MO 63143
Phone:(314) 951-2534
BID SET RENOVATE WAREHOUSE FOR
PANDEMIC PREPAREDNESS
HARRY S. TRUMAN MEM. VETERANS HOSPITAL
800 HOSPITAL DR., COLUMBIA MO 65201
BID SET 03/24/2021
Dwg. # of 94
C
L H
D C
\H o m e
\t fi e s e lm a n \R e v it M o d e ls \R
-2
-2
A
-2
-1
R e n o v a te W a re h o u s e tf ie s e lm a n A
G
Y .r v t
/2
/2
:4
:5
A
M
RA101
EXISTING CONDITIONS PLAN &
EXTERIOR PHOTOS
AHT TJF03/24/2021
1/8" = 1'-0"1
EXISTING CONDITION FLOOR PLAN
NOT TO SCALEE
EXT. WH SE CORNER-DRIVE
NOT TO SCALEI
EXT. WH S. WALL, W. END-DR. W03B
NOT TO SCALEG
EXT. WH S. WALL, RECV'G DOCK
NOT TO SCALEF
EXT. WH S. WALL, E. END-DR. W02B
NOT TO SCALEH
EXT. WH SOUTH WALL - W. END
NOT TO SCALEJ
EXT. BETWEEN WH-CHILLER PLANT
NOT TO SCALED
EXT. WH SE CORNER-TANK FARM
NOT TO SCALEC
EXT. WH E. WALL-CONN. CORR.
NOT TO SCALEB
EXT. WH E WALL-CORR CBG1
NOT TO SCALEK
EXT. WH SW CNR-CHILLER PLANT
NOT TO SCALEA
EXT. BLDG. 1 CORR CBG1 ROOF
EXIST AC CONDENSER TO REMOVE
EXIST ROLLED ROOFING
EXIST GUTTER
EXIST AREAWAY / BAR GRATING
EXIST CONC WALL/
EXIST WALL/SLOPED ROOF
APPROXIMATE AREA NEW AHU;
CURB TO MOUNT OVER TOP
OF EXIST ROOF
EXIST GUTTER
EXIST PVC DRAIN LINE-WH ROOF
EXIST CONC WALL - CORRIDOR
EXIST AREAWAY / BAR GRATING
EXIST CONC WALL/
EXIST ROLLED ROOFING
NEW DUCTWORK PENETRATION
THRU EXIST CMU - SEE MECH FOR
LOCATIONS
EXIST ROLLED ROOF UP FACE OF
WALL / TERMINATION BAR
EXIST CONDUIT / SUPPORTS
EXIST CHILLER LINE
EXIST CONC WALL - WAREHOUSE
EXIST CMU WALL -
ABOVE CONC WALL
NEW DUCTWORK PENETRATION
THRU EXIST CMU - SEE MECH FOR
LOCATIONS
CONNECTING
CORRIDOR SOUTH
WALL
EXIST DOWNSPOUT
EXIST DOWNSPOUT
BOOT / CONNECTOR
AREA TO BE KEPT
OPEN FOR DURATION
OF PROJECT
BLDG 23 CHILLER
PLANT OH DOOR
BLDG 14 WAREHOUSE
BLDG 14 WAREHOUSE
RECEIVING DOCKS BLDG 14 WAREHOUSE
RECEIVING DOCKS
EXIST ACCESS
CONTROL - SEE
ELECT/TECH DWGS
EXIST EXHAUST FAN -
SEE MECH DWGS
EXIST FIRE DEPT
SIAMESE
CONNECTION
EXIST CONC APRON -
MUST BE KEPT OPEN
AT ALL TIMES
EXIST RECEIVING
DOCK
EXIST DRIVE TO
CHILLER PLANT -
MUST BE KEPT OPEN
AT ALL TIMES
EXIST DOWNSPOUT (TYP) -
CONNECT TEMPORARY
DOWNSPOUT TO EXIST -
REPLACE W/ NEW
EXIST GUTTER TO
REMOVE
EXIST SPLIT-FACE
CMU - MATCH FOR
NEW CONST
APPROX EXTENTS NEW EXT
WALL - PROVIDE TEMP
ENCLOSURE DURING DEMO/RENO
COORD W/ COR FOR
MATERIAL LAY-DOWN
AREAS
EXIST DOWNSPOUT (TYP) -
CONNECT TEMPORARY
DOWNSPOUT TO EXIST -
REPLACE W/ NEW
EXIST GUTTER TO
REMOVE
EXIST BATTEN SEAM
METAL ROOF TO
REMOVE
EXIST EXTERIOR
DOORS - SEE DWGS
FOR NEW HW AND
ACCESS CONTROL
EXIST BATTEN SEAM METAL
ROOF TO REMOVE
EXIST GUTTER /
FASCIA TO REMOVE
CHILLER PLANT
WALK-OUT DOOR
SEE MECH FOR EXH FAN
REMOVAL; - INFILL W/ SPLIT-
FACE CMU
REMOVE EXIST HM
DOOR/FRAME - INFILL
W/ SPLIT-FACE CMU
EXIST LIGHT FIXTURE - SEE
ELEC FOR EXTERIOR
LIGHTING WORK
EXIST CHILLER PLANT OH DOOR
EXIST CHILLER PLANT WALK-OUT DOOR
BLDG 23 - CHILLER PLANT
BLDG 14 - WAREHOUSE
EXIST DOWNSPOUT (TYP) - CONNECT TEMPORARY
DOWNSPOUT TO EXIST - REPLACE W/ NEW
EXIST GUTTER/FASCIA & TOP COURSE 4"H CMU TO REMOVE
EXIST BATTEN SEAM METAL ROOF TO REMOVE
EXIST EXTERIOR DOORS W03B - SEE DWGS
FOR NEW HW AND ACCESS CONTROL
EXIST FIRE HYDRANT - MUST BE
ACCESSIBLE AT ALL TIMES
EXIST DRIVE - MUST BE
ACCESSIBLE AT ALL TIMES
EXIST STEAM LINE
THROUGH WH TO CHILLER
PLANT - SEE MECH
EXIST ELECT/COMM CONDUITS
THROUGH WH TO CHILLER
PLANT - SEE ELECT/TECH
NOT TO SCALEO
EXT. CHILLER LINES-N. FENCE
NOT TO SCALEP
EXT. WH N. WALL-CHILLER LINES
NOT TO SCALEL
EXT. WH W. EXTERIOR DOOR FROM W03A
NOT TO SCALEQ
EXT. EXIST ROOF PANEL DETAIL
NOT TO SCALEN
EXT. WH N. WALL - WEST END
NOT TO SCALEM
EXT. WH NW CNR. AT NEW STAIR
EXIST SM GUTTER
EXIST PREFIN SM FASCIA
EXIST SM ROOF BATTEN CAP W/
EXPOSED FASTENERS
EXIST PREFIN BATTEN ROOF PANEL (TYP)
EXIST SEALANT FILL AT END OF BATTEN
EXIST PREFIN SM FASCIA
EXIST SM ROOF BATTEN CAP W/ EXPOSED FASTENERS
(TYP)
EXIST GUTTER TO REMAIN EAST OF GRID LINE 4 -
SEE DEMO & RENO ROOF PLANS
EXIST DOWNSPOUT BOOT / CONNECTOR / PVC DRAIN
LINE TO REMAIN - SEE DEMO & RENO ROOF PLANS
FOR EXTENTS
EXIST DOWNSPOUT TO REMAIN EAST OF GRID LINE
4 - SEE DEMO & RENO ROOF PLANS FOR EXTENTS
EXIST CONC PIPE SUPPORT PIER /SUPPORTS (TYP)
EXIST BATTEN SEAM ROOF TO REMAIN EAST OF GRID
LINE 4 - SEE PHASING, DEMO & RENO ROOF PLANS
EXIST CHILLED WATER LINES FROM CHILLER PLANT
(TYP) - PROTECT DURING CONSTRUCTION - REVEIW
METHODS OF PROTECTION W/ COR FOR APPROVAL
PRIOR TO START OF WORK
APPROXIMATE LOCATION OF BREAK IN ROOF - GRID
LINE 4 - SEE DEMO & RENO DRAWINGS
EXIST BATTEN SEAM ROOF TO REMOVE WEST OF GRID
LINE 4 - SEE PHASING, DEMO & RENO ROOF PLANS
EXIST SPLIT-FACE CMU OVER CAST-IN-PLACE CONC
RETAINING WALL
EXIST SECURITY FENCE
NORTH OF CW LINES (TYP)
EXIST BLDG. 1 OR-SPS ADDITION
EXIST SPLIT-FACE CMU WALL
EXIST SECURITY FENCE NORTH OF CW LINES (TYP)
EXIST CONC PIPE SUPPORT PIER /SUPPORTS (TYP)
EXIST CHILLED WATER LINES FROM CHILLER PLANT
(TYP) - PROTECT DURING CONSTRUCTION - REVEIW
METHODS OF PROTECTION W/ COR FOR APPROVAL
PRIOR TO START OF WORK
EXIST BLDG. 1 OR-SPS ADDITION
AREA OF NEW EXTERIOR FIRE STAIR
EXIST CHILLED WATER LINES FROM
CHILLER PLANT (TYP) - PROTECT
DURING CONSTRUCTION - REVEIW
METHODS OF PROTECTION W/ COR
FOR APPROVAL PRIOR TO START OF
WORK
EXIST DOWNSPOUT TO REPLACE
WEST OF GRID LINE 4 - SEE DEMO &
RENO ROOF PLANS FOR EXTENTS
EXIST DOWNSPOUT BOOT /
CONNECTOR / PVC DRAIN LINE /
SUPPORTS TO REMAIN - SEE DEMO &
RENO ROOF PLANS FOR EXTENTS
EXIST SPLIT-FACE CMU OVER CAST-IN-
PLACE CONC RETAINING WALL
EXIST GUTTER TO REMOVE WEST OF
GRID LINE 4 - SEE DEMO & RENO ROOF
PLANS
EXIST CONDENSATE DRAIN LINE TO
REMOVE - FILL HOLE THROUGH WALL
W/ GROUT & SEAL - SEE MECH
EXIST GRADE SLOPES DOWNHILL FROM
NE CORNER OF WAREHOUSE
EXIST SPLIT-FACE CMU WALL
EXIST SECURITY FENCE NORTH OF CW LINES (TYP)
EXIST CONC PIPE SUPPORT PIER / PIPE SUPPORTS (TYP)
EXIST CHILLED WATER LINES FROM CHILLER PLANT (TYP) -
PROTECT DURING CONSTRUCTION - REVEIW METHODS OF
PROTECTION W/ COR FOR APPROVAL PRIOR TO START OF WORK
EXIST BLDG. 1 OR-SPS ADDITION
AREA OF NEW EXTERIOR FIRE STAIR - LOCATE EXISTING UNDERGROUND UTILITIES
PRIOR TO EXCAVATION - SEE SURVEY, PHASING, DEMO & RENO DRAWINGS
EXIST SPLIT-FACE CMU WALL
EXIST SANITARY SEWER MANHOLE - SEE SURVEY
EXTEND EXISTING CONC WALK UP TO AND UNDER NEW FIRE STAIR
EXIST HM DOOR / FRAME - DOOR IS WELDED SHUT - REMOVE
DOOR/FRAME AND INFILL W/ CMU TO MATCH EXISTING.
EXIST CONC WALK BETWEEN CHILLED WATER PLANT
AND WAREHOUSE
Revisions: Date:
FD
A
D
B C
J
LM
K
F
E
BULK/UNIT
STORAGE
W03
DRUG
CACHE/STORAGE
W03A
PROSTHETICS
STORAGE
W04A
PROSTHETICS
STORAGE
W04
EQUIPMENT
PREP
STAGING
W05A
STERILE
CONSUMABLES
(SOFT
GOODS)
STORAGE
W05
STORAGE
W06
CORRIDOR
WC02BREAK
ROOM
W07
SUPERVISOR
OFFICE
W09
STAFF
TLT
W08
VCS
STORAGE
W01
RECEIVING
DOCK
W02
CORRIDOR
WC01
RECEIVE/ISSUE
W10C
RECEIVE/ISSUE
W10A
RECEIVE/ISSUE
W10B
CORRIDOR
WC01A
G
H
I
BLDG. 23 -
CHILLER
PLANT
BLDG. 14 -
WAREHOUSE
BLDG. 1 -
HOSPITAL
CONNECTING
CORRIDOR
O
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Calvin rchitects, P.C.L 3705 North 200th Street
Elkhorn, Nebraska 68022
Phone: 402.291.6941 Fax: 402.291.9193
AH. INZ
Incandescence Life Safety, Inc.
3575 Ringsby Court, #408, Denver, CO, 80216
Phone:(720) 722-3010
589A4-20-158
IMEG Corp.
15 Sunnen Drive, Suite 104
St. Louis, MO 63143
Phone:(314) 951-2534
BID SET RENOVATE WAREHOUSE FOR
PANDEMIC PREPAREDNESS
HARRY S. TRUMAN MEM. VETERANS HOSPITAL
800 HOSPITAL DR., COLUMBIA MO 65201
BID SET 03/24/2021
Dwg. # of 94
C
L H
D C
\H o m e
\t fi e s e lm a n \R e v it M o d e ls \R
-2
-2
A
-2
-1
R e n o v a te W a re h o u s e tf ie s e lm a n A
G
Y .r v t
/2
/2
:4
:5
A
M
RA102
EXISTING CONDITIONS PLAN & INT.
PHOTOS - WEST WAREHOUSE
AHT TJF03/24/2021
1/8" = 1'-0"1
EXISTING CONDITION FLOOR PLAN
NOT TO SCALEA
RM. W03A SE CORNER
NOT TO SCALED
RM. W03A NW CORNER
NOT TO SCALEB
RM. W03A WEST WALL
NOT TO SCALEC
RM. W03A SW CORNER
NOT TO SCALEJ
RM. W03B LOOKING NORTHWEST
NOT TO SCALEL
RM. W03B SOUTHWEST CORNER
NOT TO SCALEM
RM. W03A-W03B CORNER @ BEAM
NOT TO SCALEK
RM. W03-W03A-W03B CORNER
NOT TO SCALEF
RM. W03 CEILING LOOKING WEST
NOT TO SCALEE
RM. W03 NORTH WALL / BEAM
NOT TO SCALEG
RM. W03 LOOKING EAST
NOT TO SCALEH
RM. W03 LOOKING NORTH EAST
NOT TO SCALEI
RM. W03 LOOKING NORTH
EXIST HM DOOR/FRAME TO REMOVE
EXIST PURLINS TO REMOVE (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE (TYP)
EXIST PEMB FRAME TO REMOVE
EXIST ALARM AND ACCESS CONTROL BOXES (TYP) - SEE
ELECT/TECH
EXIST DUCTWORK TO REMOVE (TYP) - SEE MECH
EXIST WIRE CAGE ENCLOSURE TO BE DISASSEMBLED, STORED AND
REASSEMBLED BY CONTR. SEE ELECT/TECH FOR ACCESS
CONTROLS
EXIST GWB/MTL STUD WALL INFILL BETWEEN PURLINS TO REMOVE
(TYP)
EXIST GWB/MTL STUD WALL TO REMOVE (TYP)
EXIST PURLINS TO REMOVE (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE (TYP)
EXIST PEMB FRAME TO REMOVE
EXIST FAN/GUARD TO REMOVE (TYP) - INFILL W/ CMU - SEE MECH
PORTION OF EXIST CMU TO REMOVE FOR NEW
UPPER EXTERIOR WALL - SEE EXTERIOR ELEVS
EXIST PEMB FRAME TO REMOVE (TYP)
EXIST PURLINS TO REMOVE (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE (TYP)
EXIST PEMB FRAME TO REMOVE
EXIST FAN/GUARD TO REMOVE (TYP) - INFILL W/ CMU - SEE MECH
PORTION OF EXIST CMU TO REMOVE FOR NEW UPPER EXTERIOR
WALL - SEE EXTERIOR ELEVS
EXIST PEMB FRAME TO REMOVE (TYP)
EXIST PURLINS TO REMOVE (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE (TYP)
EXIST PEMB FRAME TO REMOVE (TYP)
EXIST FIXED AND MOVEABLE EQUIPMENT TO BE REMOVED BY VA
PRIOR TO DEMO (TYP)
EXIST UNIT HEATER TO REMOVE (TYP) - SEE MECH
EXIST HVAC EQUIPMENT/DUCTWORK TO REMOVE (TYP) - SEE MECH
EXIST PURLINS TO REMOVE (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE (TYP)
EXIST PEMB FRAME TO REMOVE
EXIST 4"H CMU TO REMOVE (TYP)
PORTION OF EXIST CMU TO REMOVE FOR NEW
UPPER EXTERIOR WALL - SEE EXTERIOR ELEVS
EXIST PEMB FRAME TO REMOVE (TYP)
EXIST PALLET RACKS (TYP) - CONTR TO COORDINATE
W/ VA FOR REMOVAL/REINSTALLATION BY VA DURING
DEMOLITION / CONSTRUCTION
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST PALLET RACKS (TYP) - CONTR TO COORDINATE W/
VA FOR REMOVAL/REINSTALLATION BY VA DURING
DEMOLITION / CONSTRUCTION
EXIST FIXED AND MOVEABLE EQUIPMENT TO BE REMOVED BY VA
PRIOR TO DEMO (TYP)
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST FIRE SPRINKLER PIPING TO REMOVE - SEE FIRE
SUPPRESSION
EXIST PURLINS / BRACING TO
REMOVE (TYP)
EXIST VINYL SCRIM-FACED
INSULATION TO REMOVE (TYP)
EXIST PEMB FRAME TO REMOVE (TYP)
EXIST DATA CABLING (TYP) - SEE
ELECT/TECH
EXIST GWB/MTL STUD WALL TO
REMOVE (TYP)
EXIST PURLINS / BRACING TO REMOVE (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE
(TYP)
EXIST PEMB FRAME TO REMOVE (TYP)
EXIST GWB/MTL STUD WALL TO REMOVE (TYP)
EXIST PALLET RACKS (TYP) - CONTR TO
COORDINATE W/ VA FOR REMOVAL/REINSTALLATION
BY VA DURING DEMOLITION / CONSTRUCTION
EXIST FIXED AND MOVEABLE EQUIPMENT TO BE
REMOVED BY VA PRIOR TO DEMO (TYP)
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST FIRE SPRINKLER PIPING TO REMOVE -
SEE FIRE SUPPRESSION
EXIST PEMB FRAME TO REMOVE (TYP)
EXIST SHELVING (TYP) - CONTR TO COORDINATE W/ VA
FOR REMOVAL/REINSTALLATION BY VA DURING
DEMOLITION / CONSTRUCTION
EXIST FIXED AND MOVEABLE EQUIPMENT TO BE
REMOVED BY VA PRIOR TO DEMO (TYP)
EXIST PALLET RACKS (TYP) - CONTR TO COORDINATE W/
VA FOR REMOVAL/REINSTALLATION BY VA DURING
DEMOLITION / CONSTRUCTION
EXIST GWB/MTL STUD WALL TO REMOVE (TYP)
EXIST ACCESS CONTROL & SECURITY
EQUIPMENT (TYP) - SEE ELECT/TECH
EXIST ACCESS CONTROL DOOR TO REMOVE - SEE
ARCH/ELECT/TECH
EXIST FIXED AND MOVEABLE EQUIPMENT TO BE
REMOVED BY VA PRIOR TO DEMO (TYP)
EXIST PALLET RACKS (TYP) - CONTR TO COORDINATE
W/ VA FOR REMOVAL/REINSTALLATION BY VA DURING
DEMOLITION / CONSTRUCTION
EXIST PURLINS / BRACING TO REMOVE (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE (TYP)
EXIST CMU WALL TO REMAIN - MODIFY AS REQ'D.
FOR NEW UPPER WALL INSTALLATION
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST FIRE SPRINKLER PIPING TO REMOVE - SEE FIRE SUPPRESSION
EXIST CONC FLOOR (TYP) - SEE STRUCT/ARCH/FINISH
PLANS FOR DEMO/REPAIR/REFINISHING
EXIST FIXED AND MOVEABLE EQUIPMENT TO BE
REMOVED BY VA PRIOR TO DEMO (TYP)
EXIST PALLET RACKS (TYP) - CONTR TO COORDINATE
W/ VA FOR REMOVAL/REINSTALLATION BY VA DURING
DEMOLITION / CONSTRUCTION
EXIST PURLINS / BRACING TO REMOVE WEST OF GRID LINE 4 (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE (TYP)
EXIST CMU WALL TO REMAIN - MODIFY AS REQ'D. FOR NEW UPPER WALL
INSTALLATION AND DOORS - SEE ARCH
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST FIRE SPRINKLER PIPING TO REMOVE - SEE FIRE SUPPRESSION
EXIST CONC FLOOR (TYP) - SEE STRUCT/ARCH/FINISH
PLANS FOR DEMO/REPAIR/REFINISHING AND MARKINGS
EXIST PEMB FRAME-GRID LINE 4 TO REMAIN
EXIST CMU WALL & CONC DECK TO REMOVE - SEE PHASING & DEMO
EXIST FURNITURE, SHELVING, FIXED AND MOVEABLE EQUIPMENT
TO BE REMOVED BY VA PRIOR TO DEMO (TYP) - COORDINATE W/
COR FOR STORAGE AND REUSE IN RENOVATION
EXIST PURLINS / BRACING TO REMOVE WEST OF FRAME/GRID LINE 4 (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE WEST OF GRID LINE 4 (TYP)
EXIST LOUD SPEAKER (TYP) - SEE ELECT/TECH
EXIST FIRE SPRINKLER PIPING TO REMOVE - SEE FIRE SUPPRESSION
EXIST PEMB FRAME-GRID LINE 4 TO REMAIN
EXIST CMU WALL & CONC DECK TO REMOVE - SEE PHASING & DEMO
NEW PURLINS / BRACING TO BE INSERTED IN BAY EAST OF FRAME /
GRID LINE 4-5 (TYP) - SEE STRUCT
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST UNIT HEATER TO REMOVE (TYP) - SEE MECH
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST EXTERIOR DOOR TO REMAIN - SEE HW FOR
NEW DOOR HARDWARE
EXIST FIRE ALARM PULL/STROBE/HORN (TYP) - SEE FIRE
ALARM PLAN / SPECIFICATIONS
EXIST PURLINS / BRACING TO REMOVE WEST
OF GRID LINE 4 (TYP)
EXIST VINYL SCRIM-FACED INSULATION TO REMOVE WEST
OF GRID LINE 4 (TYP)
EXIST SPEAKER (TYP) - SEE ELECT/TECH
EXIST FIRE SPRINKLER PIPING TO REMOVE - SEE FIRE
SUPPRESSION
EXIST PEMB FRAMES TO REMOVE WEST OF GRID LINE 4
EXIST LIGHT FIXTURES TO REMOVE (TYP) - SEE ELECT
EXIST PALLET RACKS (TYP) - CONTR TO COORDINATE
W/ VA FOR REMOVAL/REINSTALLATION BY VA DURING
DEMOLITION / CONSTRUCTION
EXIST HM DOOR/FRAME (BEYOND) TO REMOVE - INFILL W/ CMU
NOT TO SCALEO
RM. W02 EAST WALL
NOT TO SCALEN
RM. W02 RECEIVING DOCK
EXIST PURLINS / BRACING TO
REMOVE (TYP)
EXIST ROOF FRAMING / INSULATION
TO REMAIN EAST OF GRID LINE 4
(TYP)
EXIST PEMB FRAME TO REMAIN
EXIST DATA CABLING (TYP) - SEE
ELECT/TECH
EXIST CMU WALL TO REMAIN (TYP)
Revisions: Date: