This is a NASA Goddard Space Flight Center (GSFC) Procedures and Guidelines document establishing contamination control protocols for Code 549 Environmental Test Engineering and Integration Branch. The directive (549-PG-8700.0.1D) details requirements for cleanroom operations, training, certification, and monitoring.
The document outlines specific processes for contamination control services including equipment cleaning, precision cleaning, facility cleaning, and certification. Personnel must complete SATERN training (Course GSFC-004-06) with a minimum 70% score before entering cleanrooms. Code 549 manages cleanroom garments and consumables, provides chemical analysis services, and certifies cleanrooms according to IEST ISO 14644-1 standards. The Chemical Analysis Laboratory screens cleanroom materials for harmful substances like silicones. Records retention requirements are specified for training records (5 years after employee separation) and various test/certification data (10 years). The directive is effective September 18, 2020 through September 18, 2025.
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DIRECTIVE NO. 549-PG-8700.0.1D APPROVED BY Signature: Original signed by:
EFFECTIVE DATE: September 18, 2020 NAME: David Robinson EXPIRATION DATE: September 18, 2025 TITLE: Code 549 Branch Head
CHECK THE GSFC DIRECTIVES MANAGEMENT SYSTEM AT
http://gdms.gsfc.nasa.gov TO VERIFY THAT THIS IS THE CORRECT VERSION PRIOR TO USE.
08/16
Procedures and Guidelines (PG)
COMPLIANCE IS MANDATORY
Responsible Office: Code 549/Environmental Test Engineering and Integration Branch Title: Contamination Control
PREFACE
P.1 PURPOSE
This document defines Code 549 Contamination Control roles and responsibilities for certification of cleanrooms, garments, etc. in support of GSFC cleanrooms/cleantents/clean benches.
P.2 APPLICABILITY
This procedure applies to Code 549.
P.3 AUTHORITY
549-PG-8700.1.1, Environmental Test & Engineering Integration Process
P.4 APPLICABLE DOCUMENTS AND FORMS
N/A
P.5 CANCELLATION
549-PG-8700.0.1C
P.6 SAFETY
N/A
P.7 TRAINING
Personnel entering cleanrooms, including CC personnel, should take the access training in SATERN (Course GSFC-004-06). Additional or separate training may be required for certain projects. Check with the project occupying the space for specifics. Personnel shall pass the course test with a score of at least 70%.
DIRECTIVE NO. 549-PG-8700.0.1D Page 2 of 5
EFFECTIVE DATE: 09/18/2020
EXPIRATION DATE: 09/18/2025
In order for CC personnel to be qualified to perform their duties, on the job training is required.
P.8 RECORDS
Record Title Record Custodian Retention
Training records Supervisor or SATERN
*NRRS 3/3400/33C- Destroy or delete 5 years after separation of employee or when no longer needed, whichever comes first.
Cleanroom Consumable test data Lab Manager and/or Supervisor
*NRRS 1/1740/124- Retire to FRC when 3 years old.
Destroy when 10 years old.
Witness (NVR) plate data Lab Manager and/or Supervisor
*NRRS 1/1740/124- Retire to FRC when 3 years old.
Destroy when 10 years old.
Cleanroom Garment test data Lab Manager and/or Supervisor
*NRRS 1/1740/124- Retire to FRC when 3 years old.
Destroy when 10 years old.
Cleanroom Certification data Lab Manager and/or Supervisor
*NRRS 1/1740/124- Retire to FRC when 3 years old.
Destroy when 10 years old.
* NRRS 1441.1 – NASA Records Retention Schedule
P.9 MEASUREMENT/VERIFICATION
N/A
PROCEDURES
1 Contamination Control Cleanroom Access Training Program
Unless otherwise required by the facility owners, cleanroom access training is required for personnel entering the cleanrooms and cleantents. (Any reference to cleanrooms throughout this document, also implies cleantents and clean benches) However, Code 549 or their designees can escort untrained personnel into a cleanroom when authorized by the project.
If a sign-in log is provided, the authorized escort should write their control number (located on the back of the Cleanroom Access Training Card) on the sign in log in the Escort Control No. column next to the visitor's name and escort the visitor into the cleanroom.
DIRECTIVE NO. 549-PG-8700.0.1D Page 3 of 5
2 Work Flow
2.1 Contamination Control Customer Requests and Implementation
The customer requesting contamination control services from Code 549 CC should complete a work request. Services included, but are not limited to: general equipment cleaning, precision cleaning, facility cleaning, facility certification, tape lift, etc. Special instructions or reference to a project’s Contamination Control Plan and/or to a project’s Work Order Authorization can be included on this document. If no special instructions are included standard clean practices will be used.
2.2 Chemical Analysis Laboratory Request and Implementation
When Code 549 CC receives a request for quantitative and/or qualitative chemical analysis, customers should provide detailed information on the service requested. When the analysis is completed, the laboratory manager communicates the end product results to the customer by email, by written report or verbally. Examples of chemical analysis requests may include:
witness plate or witness foil rinse analysis, flight hardware rinse, swab or wipe analysis, associated materials screening analysis, etc.
The Chemical Analysis Laboratory screens all cleanroom consumables per lot number and a representative amount of cleanroom garments for chemical species like silicones, which are deemed harmful to critical flight hardware and/or ground support equipment.
3 Cleanroom Garments and Consumables
Code 549 provides screened cleanroom garments and consumables to clean facilities, clean benches or clean areas throughout GSFC per customer request. Unless specified by the customer, the cleanroom garments and consumables shall be stocked, tested, stored, controlled and delivered to each cleanroom by Code 549 or their designated representative.
4 Certification and Monitoring
Cleanrooms, cleanbenches and clean areas throughout GSFC can be certified under the guidance of IEST ISO 14644-1 and the Code 549 Certification and Monitoring of Cleanrooms Manual. Code 549 will supply the necessary equipment, i.e. calibrated air particle counter and/or air velocity meter, to perform certification. Certification is performed routinely, and can also be performed per the customer’s request.
The air particle counts for cleanrooms, cleanbenches and clean areas throughout GSFC can be measured under the guidance of Code 549 Certification and Monitoring of Cleanrooms Manual, by Code 549, or their designated representatives. Code 549 will supply the necessary equipment, i.e.
calibrated air particle counter and/or air velocity meter, to take measurements. These evaluations can be performed routinely or per the customer’s request.
DIRECTIVE NO. 549-PG-8700.0.1D Page 4 of 5
5 Contamination Control and Cleanroom Operations Engineering Oversight Code 549 or their designated representative shall provide flight hardware and ground support equipment contamination control and cleanroom operations engineering oversight per the request of the customer.
DIRECTIVE NO. 549-PG-8700.0.1D Page 5 of 5
CHANGE HISTORY LOG
Revision Effective Date Description of Changes
Baseline
04/30/2012 Initial Release
A 09/08/2014 Made minor editorial changes to document.
B
04/17/2015 Added several new headings in “Procedure” and added new Appendix
C 7/30/2015 Updated to remove documents not under Code 549 control, changed records requirements, and added required training.
D 09/18/2020 Revalidation w/ Administrative changes Newest template