Attachment 33 - Drawings Part-32.pdf
PDF 9 MB Posted
- Attached to
- Y1DA--EHRM Infrastructure Upgrades Construction Jefferson Barracks Federal contract opportunity
- Solicitation number
- 36C77623R0009
About this file
This solicitation seeks a general contractor to provide infrastructure upgrades at the St. Louis Jefferson Barracks VA Medical Center campus. The scope of work includes electrical system upgrades including panels, power, bonding and UPS; building management system interfaces; HVAC assessments, renovations and expansions; data center renovations; communication infrastructure upgrades including new data outlets, patch panels and Cat6A cabling; physical security upgrades; and fiber infrastructure assessments and upgrades both within and between buildings. The buildings included are 1, 2, 3, 3T, 18, 23, 24, 25, 51, 51T, 52, 53, 53T, 55, 56, 57, 58, 59, 60, 60T, 61 and 75. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 50
Y1DA--EHRM Infrastructure Upgrades Construction Jefferson Barracks has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYP
TYP
TYP
TYP
TYP
TYP
TYP
86"
BOTTOM 3RD SECTION
OF RACK IS
DESIGNATED TO
POWER DISTRIBUTION
EQUIPMENT.
REFERENCE
ELECTRICAL SHEET
EP502 FOR MORE
INFORMATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
BOTTOM 3RD SECTION
OF RACK IS
DESIGNATED TO
POWER DISTRIBUTION
EQUIPMENT.
REFERENCE
ELECTRICAL SHEET
EP502 FOR MORE
INFORMATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
BOTTOM 3RD SECTION
OF RACK IS
DESIGNATED TO
POWER DISTRIBUTION
EQUIPMENT.
REFERENCE
ELECTRICAL SHEET
EP502 FOR MORE
INFORMATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
TYP
TYP
TYP
TYP
TYP
TYP
TYP
86"
BOTTOM 3RD SECTION
OF RACK IS
DESIGNATED TO
POWER DISTRIBUTION
EQUIPMENT.
REFERENCE
ELECTRICAL SHEET
EP502 FOR MORE
INFORMATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
BOTTOM 3RD SECTION
OF RACK IS
DESIGNATED TO
POWER DISTRIBUTION
EQUIPMENT.
REFERENCE
ELECTRICAL SHEET
EP502 FOR MORE
INFORMATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
BOTTOM 3RD SECTION
OF RACK IS
DESIGNATED TO
POWER DISTRIBUTION
EQUIPMENT.
REFERENCE
ELECTRICAL SHEET
EP502 FOR MORE
INFORMATION
TYP
TYP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 32 33 34 35 36
TYP
TYP
TYP
TYP
TYP
86"
TYP
TYP
86"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
ST. LOUIS VA MEDICAL CENTER - JEFFERSON BARRACKS, MO
657-21-701JB
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES ET502
TELECOMMUNICATIONS DETAILS
LRL/WNM JBB
CONSTRUCTION
DOCUMENTS
03/31/2022
- NTS
1 TR DATA RACK ELEVATION - THREE RACK
- NTS
3 TR DATA RACK ELEVATION - TWO RACK
- NTS
4 TR DATA RACK ELEVATION - SINGLE RACK
GENERAL NOTES (FOR THIS SHEET ONLY)
1. ALL TELECOMMUNICATIONS ROOM (TR) DATA RACK DETAIL ELEVATIONS
ARE SHOWN TO PROVIDE GENERAL LAYOUT REQUIREMENTS. EXACT
QUANTITIES OF UTP PATCH PANELS AND NETWORK SWITCHES PER TR ARE
SHOWN IN THE TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE
LOCATED ON SHEET ET701. IF MORE THAN (1) RACK IS PRESENT IN THE TR
BEING EVALUATED, CONTRACTOR SHALL DIVIDE THE PATCH PANEL AND
NETWORK SWITCH EQUIPMENT EVENLY AMONG THE RACKS [IE: IF (6)
PATCH PANELS AND (6) NETWORK SWITCHES ARE REQUIRED IN A TR THAT
HAS (2) DATA RACKS, PROVIDE EACH DATA RACK WITH (3) PATCH PANELS
AND (3) NETWORK SWITCHES].
2. VA DATA RACKS FOLLOW A RULE OF THIRDS FOR POSITIONING EQUIPMENT
ON THE RACK. THE TOP THIRD IS DESIGNATED FOR FIBER AND UTP PATCH
EQUIPMENT, THE MIDDLE THIRD IS DESIGNATED FOR NETWORK SWITCH
EQUIPMENT, AND THE BOTTOM THIRD IS DESIGNAZTED FOR DATA RACK
POWER DISTRIBUTION EQUIPMENT.
3. PRIOR TO CONSTRUCTING TR DATA RACKS AND DURING THE SUBMITTAL
PROCESS, CONTRACTOR SHALL SUBMIT ALL TR DATA RACK ELEVATIONS
(FRONT, BACK, AND SIDE VIEWS) FOR ENGINEER AND VA REVIEW AND
APPROVAL. SUBMITTAL SHALL SHOW ALL DIMENSIONS, CABLE
MANAGEMENT EQUIPMENT, LABELING AND ASSOCIATED CUTSHEETS WITH
INDICATED PART NUMBERS AND OPTIONS FOR ALL EQUIPMENT.
4. CONTRACTOR SHALL LABEL EACH PATCH PANEL PORT WITH PORT NUMBER
AND ROOM NUMBER.
5. ALL DATA RACKS SHALL BE PROVIDED WITH SEISMIC BRACING KITS AND
INSTALLED PER MANUFACTURER'S INSTRUCTIONS.
6. ALL EQUIPMENT, CABLING, CONNECTORS AND APPURTENANCES SHALL BE
LABELED PER THE VA STANDARD "INFRASTRUCTURE STANDARD FOR
TELECOMMUNICATIONS SPACE" VERSION 3.1 OR NEWER.
7. WHERE RACK EQUIPMENT IS NOT REQUIRED FOR CABLING REQUIREMENTS
PROVIDE BLANKING PLATES IN ABSENT SPACES.
KEY NOTES (FOR THIS SHEET ONLY)
DATA RACK, 4-POST, WHITE FINISH, ORTRONICS #MM2073038-W, OR
APPROVED EQUAL.
VERTICAL CABLE MANAGER WITH DOOR, 6" WIDE, ORTRONICS
#MM20VMD706, OR APPROVED EQUAL.
FIBER DISTRIBUTION CABINET, ANGLED, 1RU, LEVITON ANGLED OPT-X
UHDX, OR APPROVED EQUAL; CABINET POPULATED WITH (12) CASSETTES,
LEVITON HDX ENTERPRISE MTP, OR APPROVED EQUAL. SIDE-A AND SIDE-B
FIBER BACKBONE SHALL TERMINATE TO SEPARATE SIDES OF DISTRIBUTION
CABINET.
CAT 6A UTP PATCH PANEL, ANGLED, 48-PORT WITH REAR CABLE MANAGER,
LEVITON #E2XHD-BLK, OR APPROVED EQUAL.
BLANKING PANEL, 1RU, LEVITON, OR APPROVED EQUAL.
HORIZONTAL CABLE MANAGER, 1RU OR 2RU AS SHOWN, LEVITON, OR
APPROVED EQUAL.
NETWORK SWITCH. VA PROVIDED, CONTRACTOR INSTALLED.
COORDINATE WITH VA FOR EXACT REQUIREMENTS AS NECESSARY.
DETAIL IS GENERIC IN NATURE AND SHOWS
GENERAL LAYOUT INFORMATION. REFERENCE
GENERAL AND KEY NOTES FOR SPECIFIC
INFORMATION
DETAIL IS GENERIC IN NATURE AND SHOWS GENERAL
LAYOUT INFORMATION. REFERENCE GENERAL AND
KEY NOTES FOR SPECIFIC INFORMATION
DETAIL IS GENERIC IN NATURE AND SHOWS GENERAL LAYOUT INFORMATION.
REFERENCE GENERAL AND KEY NOTES FOR SPECIFIC INFORMATION
Revisions: Date:
- NTS
2 TR DATA RACK ELEVATION - FIBER-OPTIC BACKBONE TERMINATION RACK
DETAIL IS GENERIC IN NATURE AND SHOWS
GENERAL LAYOUT INFORMATION.
REFERENCE GENERAL AND KEY NOTES FOR
SPECIFIC INFORMATION
SINGLE GANG WORKBOX
WITH TWO CONNECTOR
CHASSIS
FOUR CATEGORY 6A 8P8C
OUTLETS ACTIVE FOR
TELEPHONY/DATA
FOUR POSITION FACEPLATE
MOUNTED ON SINGLE GANG
WORKBOX. FACEPLATE
COLOR SPECIFIED BY
OTHERS.
1 2
3 4
SINGLE GANG WORKBOX WITH
ONE CONNECTOR CHASSIS.
TWO CATEGORY 6A 8P8C
OUTLETS ACTIVE FOR
TELEPHONY/DATA
FOUR POSITION FACEPLATE
MOUNTED ON SINGLE GANG
WORKBOX. FACEPLATE
COLOR SPECIFIED BY
OTHERS.
1 2
3 4
T568B 8P8C
T568B
B N
/W H
B N
O R
/W H
O R
G N
/W H
G N
B L /W
H
B L
EXISTING CONDUIT
(ASSUMED SIZE = 3/4")
EXISTING FACEPLATE
LABEL WINDOW
EXISTING JACK MODULES
PROVIDE CAT-6A MODULES
TO REPLACE EXISTING JACKS
PROVIDE BLANK MODULES TO
FILL UNUSED PORT OPENINGS
PROVIDE CAT-6A
CABLING THROUGH
EXISTING CONDUIT
EXISTING DATA OUTLET CONFIGURATION REVISED DATA OUTLET CONFIGURATION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
ST. LOUIS VA MEDICAL CENTER - JEFFERSON BARRACKS, MO
657-21-701JB
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES ET503
TELECOMMUNICATIONS DETAILS
LRL/WNM JGE/JBB
CONSTRUCTION
DOCUMENTS
03/31/2022
- NTS
4 TYPICAL HIGH DENSITY WALL MOUNTED WORK AREA OUTLET CONFIGURATION
- NTS
5 STANDARD DENSITY WALL MOUNTED WORK AREA OUTLET CONFIGURATION
- NTS
3 DATA CABLING TERMINATION DETAIL
- NTS
1 EXISTING DATA OUTLET MODIFICATION
NTS
FIRE STOP SLEEVE AND GANGPLATE DETAIL2
FIRE STOP GANGPLATE, SIZE AS
REQUIRED, HILTI #CFS-SL GP, OR
APPROVED EQUAL.
DO NOT USE FOR FLOOR
PENETRATIONS UNLESS
SPECIFICALLY APPROVED BY
MANUFACTURER FOR THAT
APPLICATION.
FIRE STOP SPEED SLEEVE, HILTI
#CFS-SL GA L, OR APPROVED EQUAL
1. ALL LABELING SHALL BE ANSI/TIA/EIA/606C COMPLIANT. BLACK LETTERING ON WHITE
FIELD. MACHINE PRINTED. FURTHER GUIDANCE ON ADMINISTRATION MAY BE SPECIFIED
IN OTHER SECTIONS OF THIS DESIGN PACKAGE.
2. TYPICAL WORK AREA OUTLET FACEPLATE WILL BE INSTALLED WITH CATEGORY 6A
COMPONENT-COMPLIANT 8P8C MEDIA INTERFACE CONNECTORS (RJ45). EACH
CONNECTOR WILL BE TERMINATED TO HIGH QUALITY CATEGORY 6A HORIZONTAL
CABLING WHICH WILL TERMINATE IN THE TELECOMMUNICATIONS ROOM AS SPECIFIED
ELSEWHERE IN THIS DESIGN PACKAGE. ALL HORIZONTAL UTP SHALL BE CATEGORY 6A
AND TERMINATED TO T568B.
3. TYPICAL FACEPLATE WILL BE INSTALLED WITH TWO (2) RJ45s. HIGH DENSITY FACEPLATES WILL BE INSTALLED WITH FOUR (4) RJ45s.
4. FACEPLATE MATERIAL AND COLOR DETERMINED BY OTHERS.
GENERAL NOTES (FOR THIS SHEET ONLY)
Revisions: Date:
CABLOFIL WIRE
BASKET CABLE TRAY
BY LEGRAND, OR
APPROVED EQUAL
LENGTH AS
REQUIRED
- 1 : 30
6 WIRE BASKET CABLE TRAY
PROVIDE FIRE PROOFING,
CAULKING, AND ANY REQUIRED
APPURTENANCES PER THE
SPECIFICATIONS AND
MANUFACTURER'S REQUIREMENTS
AS REQUIRED
NOTE 1
NOTE 1
DETAILS NOTES (FOR THIS DETAIL ONLY)
NOTE 1. REFERENCE TELECOMMUNICATIONS WAO AND CABLE TRAY
SCHEDULE ON SHEET ET701 FOR DIMENSIONS
NOTE 2. CONTRACTOR MAY USE TEMPORARY CABLE HANGERS OR OTHER MEANS WHILE
ROUTING CABLE TO ITS INTENDED DESTINATION; HOWEVER, PRIOR TO FINAL
INSTALLATION, CABLE SHALL BE INSTALLED TO BE HOUSED WITHIN CABLE TRAY
AND NOT ON TEMPORARY CABLE HANGERS.
SIDE-B FIBER OPTIC
BACKBONE
TERMINATION RACK
BUILDING 1
GC12
B
FIBER OPTIC PATCH
PANEL
C102D
FIBER OPTIC PATCH
PANEL
2C10A
FIBER OPTIC PATCH
PANEL
1E15
FIBER OPTIC PATCH
PANEL
E303
FIBER OPTIC PATCH
PANEL
3C13
FIBER OPTIC PATCH
PANEL
BUILDING 2
G04
BA
FIBER OPTIC PATCH
PANEL
A B
FIBER OPTIC PATCH
PANEL
A B
FIBER OPTIC PATCH
PANEL
BUILDING 3
B025A
BA
FIBER-OPTIC PATCH
PANEL
A B
FIBER-OPTIC PATCH
PANEL
FIBER OPTIC PATCH
PANEL
BUILDING 3T
FIBER OPTIC PATCH
PANEL
BUILDING 23
G09B
BA
FIBER OPTIC PATCH
PANEL
121A
FLOOR 1
FLOOR 0
FLOOR 2
FLOOR 3
FLOOR 0
FLOOR 1
FLOOR 0
FLOOR 1
FLOOR 2
FLOOR 3
FLOOR 0
FLOOR 1
FLOOR 2
A
B
A B
A
A
SIDE-A FIBER OPTIC
BACKBONE
TERMINATION RACK
WALL MOUNTED
TDU AIR BLOWN
FIBER
AB
A
A B B
B
A
B
B
ALL CAMPUS SIDE A
TERMINATES HERE
RACK MOUNTED
SPLICE CASE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A
B
FLOOR 1
FIBER OPTIC PATCH
PANEL
BUILDING 18
011A
BA
FIBER OPTIC PATCH
PANEL
A B
FIBER OPTIC PATCH
PANEL
A B
FIBER OPTIC PATCH
PANEL
FLOOR 0
FLOOR 1
FLOOR 2
FLOOR 3
A
BRACK MOUNTED
SPLICE CASE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A
B
RACK MOUNTED
SPLICE CASE
WALL MOUNTED TDU
AIR BLOWN FIBER
A
A B B
FIBER OPTIC PATCH
PANEL
BUILDING 24
G02A
BA
FIBER OPTIC PATCH
PANEL
114B
A B
FIBER OPTIC PATCH
PANEL
205A
FLOOR 0
FLOOR 1
FLOOR 2
A
BRACK MOUNTED
SPLICE CASE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A
B
FIBER OPTIC PATCH
PANEL
A
BRACK MOUNTED
SPLICE CASE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A
B
G05 - NOT A TR
1. REFERENCE COMMUNICATIONS DRAWINGS FOR ADDITIONAL SITE WIDE
FIBER-OPTIC BACKBONE CABLING INFORMATION.
2. REFERENCE COMMUNICATIONS DRAWINGS FOR ALL FIBER-OPTIC CABLING AS
REQUIRED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
ST. LOUIS VA MEDICAL CENTER - JEFFERSON BARRACKS, MO
657-21-701JB
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES ET601
FIBER OPTIC NETWORK DIAGRAM
LRL/WNM JBB/JGE
CONSTRUCTION
DOCUMENTS
03/31/2022
GENERAL NOTE
KEY NOTE
A-SIDE FIBER-OPTIC BACKBONE.
B-SIDE FIBER-OPTIC BACKBONE.
A
B
Revisions: Date: 432 OF 435
1. REFERENCE COMMUNICATIONS DRAWINGS FOR ADDITIONAL SITE WIDE
FIBER-OPTIC BACKBONE CABLING INFORMATION.
2. REFERENCE COMMUNICATIONS DRAWINGS FOR ALL FIBER-OPTIC CABLING AS
REQUIRED.
FIBER OPTIC PATCH
PANEL
BUILDING 25
117A
BA
FIBER OPTIC PATCH
PANEL
204B
A B
FIBER OPTIC PATCH
PANEL
313A
FLOOR 1
FLOOR 2
FLOOR 3
A
BRACK MOUNTED
SPLICE CASE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A
B
BUILDING 51
B A
1A102
BA B
BE111
1A1831A139A
FLOOR 0
FLOOR 1
RACK MOUNTED
SPLICE CASE
FIBER OPTIC PATCH
PANEL
FIBER OPTIC PATCH
PANEL
FIBER OPTIC PATCH
PANEL
A
FIBER OPTIC PATCH
PANEL
WALL MOUNTED
TDU AIR BLOWN
FIBER
A B
A B
BUILDING 51T
FIBER OPTIC PATCH
PANEL
A B
FLOOR 1
FIBER OPTIC PATCH
PANEL
BUILDING 52
GN29A
B
FIBER OPTIC PATCH
PANEL
1N82A
FIBER OPTIC PATCH
PANEL
1S33
FIBER OPTIC PATCH
PANEL
2S53
FIBER OPTIC PATCH
PANEL
2N91
FLOOR 1
FLOOR 0
FLOOR 2
A
A
RACK MOUNTED
SPLICE CASE
WALL MOUNTED
TDU AIR BLOWN
FIBER
AB
A B BA
B
A B
FIBER OPTIC PATCH
PANEL
BUILDING 53
GS10
FIBER OPTIC PATCH
PANEL
1S002
FIBER OPTIC PATCH
PANEL
2S001
FIBER OPTIC PATCH
PANEL
1S011
FLOOR 1
FLOOR 0
FLOOR 2
A
RACK MOUNTED
SPLICE CSE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A
A B B
B
A
B
A B
FIBER OPTIC PATCH
PANEL
GS02A
A B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
ST. LOUIS VA MEDICAL CENTER - JEFFERSON BARRACKS, MO
657-21-701JB
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES ET602
FIBER OPTIC NETWORK DIAGRAM
LRL/WNM JBB/JGE
CONSTRUCTION
DOCUMENTS
03/31/2022
Revisions: Date:
GENERAL NOTE
KEY NOTE
A-SIDE FIBER-OPTIC BACKBONE.
B-SIDE FIBER-OPTIC BACKBONE.
A
1. REFERENCE COMMUNICATIONS DRAWINGS FOR ADDITIONAL SITE WIDE
FIBER-OPTIC BACKBONE CABLING INFORMATION.
2. REFERENCE COMMUNICATIONS DRAWINGS FOR ALL FIBER-OPTIC CABLING AS
REQUIRED.FIBER OPTIC PATCH
PANEL
BUILDING 53T
A B
FLOOR 1
FIBER OPTIC PATCH
PANEL
BUILDING 54
BA
FIBER OPTIC PATCH
PANEL
FLOOR 0
PENTHOUSE
A
B
RACK MOUNTED
SPLICE CASE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A
B
FIBER OPTIC PATCH
PANEL
FIBER OPTIC PATCH
PANEL
FLOOR 1
PENTHOUSE
1A133
A AB B
BA-100 BB-115
FIBER OPTIC PATCH
PANEL
BUILDING 55
1C132
FIBER OPTIC PATCH
PANEL
2A136
FIBER OPTIC PATCH
PANEL
2C144
FLOOR 2
FLOOR 1
FLOOR 3
A
RACK MOUNTED
SPLICE CSE
WALL MOUNTED
TDU AIR BLOWN
FIBER
A B BA
B
A B
FIBER OPTIC PATCH
PANEL
1B104
A B
FIBER OPTIC PATCH
PANEL
3C149
FIBER OPTIC PATCH
PANEL
3A120
A B BA
FIBER OPTIC PATCH
PANEL BB-102
BUILDING 56
BA
FIBER OPTIC PATCH
PANEL
BA-105
A B
FIBER OPTIC PATCH
PANEL
2A-122
A B
FIBER OPTIC PATCH
PANEL
3A-122
FLOOR B
FLOOR 0
FLOOR 1
FLOOR 2
A
B
RACK MOUNTED
SPLICE CASE TO
BUILDING 1 MCR
AIR BLOWN FIBER
TO RACK/s 7,8,9
BB102
A
B
BUILDING 56 BB-102
A B
FIBER OPTIC PATCH
PANEL
1A-109
FLOOR 3
FIBER OPTIC PATCH
PANEL
BUILDING 58
A B
FLOOR 1
FIBER OPTIC PATCH
PANEL
BUILDING 60
A B
FLOOR 1
FIBER OPTIC PATCH
PANEL
BUILDING 75
1B105
A B
FLOOR 1
FIBER OPTIC PATCH
PANEL
BUILDING 60T
A B
FLOOR 1
FIBER OPTIC PATCH
PANEL
1B139
BUILDING 57
FLOOR 1
A RACK MOUNTED
SPLICE CSE
WALL MOUNTED
TDU AIR BLOWN
FIBER
B
A B
FIBER OPTIC PATCH
PANEL
1B120
A B
FIBER OPTIC PATCH
PANEL
1A129
A B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
EHRM INFRASTRUCTURE
UPGRADES
ST. LOUIS VA MEDICAL CENTER - JEFFERSON BARRACKS, MO
657-21-701JB
SPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES ET603
FIBER OPTIC NETWORK DIAGRAM
LRL/WNM JBB/JGE
CONSTRUCTION
DOCUMENTS
03/31/2022
Revisions: Date:
GENERAL NOTE
KEY NOTE
A-SIDE FIBER-OPTIC BACKBONE.
B-SIDE FIBER-OPTIC BACKBONE.
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ET701
TELECOMMUNICATIONS
SCHEDULESSPEES DESIGN BUILD
625 1ST AVE, STE 301
SEATTLE, WA 98104
(206) 590-2118
RAY SPEES
EHRM INFRASTRUCTURE
UPGRADES
ST. LOUIS VA MEDICAL CENTER - JEFFERSON BARRACKS,
MO
657-21-701JB
03/31/2022 LRL/WNM JGE/JBB
CONSTRUCTION
DOCUMENTS
Revisions: Date: 435 OF 435
File details come from the government source that posted it. Updated .