This federal contract solicitation seeks construction services for infrastructure upgrades at the St. Cloud Veterans Affairs Health Care System. Work includes electrical, bonding, UPS, building management system interfaces, access security, HVAC assessments, space reconfigurations and expansions, data center/server room upgrades, fiber infrastructure upgrades within and between buildings, and hazardous materials abatement. All work must comply with specifications and contract drawings. The solicitation is issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The response deadline and award date are not specified.
View the file
Other files for this federal contract opportunity
Show all 50
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING FIBER - INSIDE
VFY EXIST
EXISTING FIBER - OUTSIDE
VFY EXIST
FIBER ROUTE - INSIDE
SEE TELECOM
FIBER ROUTE - OUTSIDE
SEE CIVIL
BUILDING OUTLINE
VFY EXIST
CORRIDOR OUTLINE
VFY EXIST
LEGEND
TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST
44TH AVE.
TRAIL 1
TRAIL 2
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2)
15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
GRAVEL
GRAVEL
GRAVEL
EXISTING
ROAD
CHAIN LINK FENCE
CHAIN LINK FENCE
16' GATE
GRAVEL
ELECTRICAL
SUBSTATION
G E N E R A T O R
FUEL LINES
CONDU ITS TO TU NNEL
M V
D U
C T
B A
N K
1 1 2 W
PHARMACY ADDITION
11 2 E
G E N E R A T O R
B
CORRIDOR LINK
A
C T
TR
A
IL
ER
174 s .f.
256 s .f.
185 s .f.
149 s ..f.
155 s .f.
104 s .f.
70 s. .f .
72 s .f.
110 s .f.
276 s .f.
112 s .f.
99 s .f.
57 s .f.
146 s .f.
434 s .f.
R A
MP
U P
1:
M A X
R A
MP
U P
1:
M A X
RA
M P
UP
1:2 0 M
AX
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2) 15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
.3
TRANSFORMER
BUILD ING
#91
5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN
O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW
C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D
P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S
R EC O M M EN D ATIO N S
N EW G AS SU P P LY M AIN
IN TO B U ILD IN G
SP AR E
P H O N E LIN E
EXTEN D S TO
E XISTIN G
P H O N E IN
B O ILER R O O M
P ER P LAN .
SP AR E
P H O N E
LIN E TO
M ETER
TU N N EL
E XTEN D S
A D D ITIO N AL
2'- 0" U N D ER
B U ILD IN G
FUEL LINE
VENT LINE
1,000 GAL.
UNDERGROUND
DIESEL FUEL
TANK
1,000/5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
S 1
LIG H T
N EW G AS SU P P LY
(C O O R D IN ATE W ITH SU P P LIER )
12"D
10"D
"D
TP TP
EXIST. BUILDING
EXIST.
BUS STOP
CC
L O
O P
16"
20"
12"
3"
8"
DN
0.
0’
BIRDCAGE
B
IR
D C
A G
E
NSP ELECTRICAL
FOR HWY DEPT
T101
I.T.
CHILLER
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
VESTIBULE
DN
DN
DN
FD
DN
F B
F
B
F B
F
B
F B
F
B
SOUTH
VESTIBULE
PASS
THROUGH
LINK TO
BUILDI NG 51
6 3. 32 56
1 13 5. 35 78
PARKING
NO
PARKING
93 29
37 6
109 5
1A
S M
O K
E B
L D
G
SMOKE
BLDG
SMOKE
BLDG
S M
O K
E B
L D
G
SMOKE
BLDG
M.H.
STOR.
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
STOR.
BIO-
HAZ.
SAUK RIVER
GP
HOLDING POND49
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
OWNER AND
CONSULTANTS:
CONTACT:
ADDRESS:
MIKE ENGMARK
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
NAME:
ADDRESS:
CONTACT:
ADVANCED STRUCTURAL TECHNOLOGIES
7301 OHMS LANE; SUITE 215
EDINA, MN 55439
ZACHARY CRAIG
PHONE:
NAME:
ADDRESS:
CONTACT:
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
PHONE: 402-991-5520
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
IAN WEBER
763-412-4000
ARCHITECT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
EDWARD MARKFORT
763-412-4000
952-854-9302
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
402-991-5520
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
COVER
DATE:
APPROVED: APPROVED: PROJECTS SECTION MANAGER
APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:
APPROVED: SAFETY MANAGER
APPROVED: CHIEF OF POLICE
APPROVED: PATIENT SAFETY
DATE:
DATE:
DATE: APPROVED: EMS MANAGER
APPROVED: M/O MANAGER
DATE:
DATE:
DATE:DATE:
APPROVED: MEDICAL CENTER DIRECTOR
APPROVED: PROJECT COR DATE:
APPROVED: INFECTION CONTROL NURSE DATE:
APPROVED: SERVICE LINE DIRECTOR
APPROVED: GEMS COORDINATOR DATE:
DATE:
APPROVED: NURSE EXECUTIVE
APPROVED: CHIEF OF STAFF DATE:
APPROVED: DIRECTOR FMS
APPROVED: ASSOCIATE DIRECTOR
DATE:
DATE:
DATE:
DATE:APPROVED: DATE:
APPROVED: DATE:
APPROVED: DATE:
Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System
N
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
VICINITY MAP:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHONE: 320-252-1670
CIVIL ENGINEER:
VA COR:
TELECOMMUNICATIONS ENGINEER:
CONTACT:
ADDRESS:
JONATHAN WEST
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
PHONE: 504-250-2699
PROGRAM MANAGER:
EMAIL: Jonathan.West@vciint.com
STRUCTURAL ENGINEER:
MECH/ELEC/PLUMB/FIRE ENGINEER:
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:0 :4
P
M
49-GI000
BUILDING 49 COVER SHEET &
SHEET INDEX
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
BUILDING 49 - EHRM INFRASTRUCTURE UPGRADES
03/30/2022
0APPROX 150' 300'75'
SHEET INDEX - BUILDING 49
SHEET NO. SHEET TITLE
49-GI000 BUILDING 49 COVER SHEET & SHEET INDEX
49-GI101 BASEMENT FLOOR - INFECTION CONTROL & PHASING PLAN
49-HA-1A REFERENCE - CRAWLSPACE FLOOR - ASBESTOS RE-SURVEY
49-HA-2A REFERENCE - BASEMENT FLOOR - ASBESTOS RE-SURVEY
49-HA-3A REFERENCE - FIRST FLOOR - ASBESTOS RE-SURVEY
49-HA-4A REFERENCE - SECOND FLOOR - ASBESTOS RE-SURVEY
49-AS100 BASEMENT PLANS
49-AS110 FIRST FLOOR - OVERALL PLAN
49-AS120 SECOND FLOOR - OVERALL PLAN
49-TD100 BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
49-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION
49-TD120 SECOND FLOOR PLAN - TELECOM - DEMOLITION
49-TN100 BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
49-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS
49-TN120 SECOND FLOOR PLAN - TELECOMMUNICATIONS
49-TN200 BASEMENT FLOOR PLAN - TELECOM - CABLE DISTANCE
49-TN300 ENLARGED PLANS -TELECOMMUNICATIONS - DEMO
49-TN400 ENLARGED PLANS - TELECOMMUNICATIONS
49-E200 BASEMENT - ELECTRICAL
49-E201 FIRST FLOOR - ELECTRICAL
49-E300 ELECTRICAL ENLARGED PLANS
49-E500 ELECTRICAL ONE-LINE DIAGRAMS
49-E600 ELECTRICAL SCHEDULES
49-M100 BASEMENT DEMOLITION - MECHANICAL
49-M200 BASEMENT - MECHANICAL
SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
ROOM SCHEDULE
NO. NAME C
A
B
LI
N G
P A
T C
H P
A N
E L
F
IB
E R
P O
W E
R
B O
N D
IN
G
U P
S
D E
D
IC
A T
E D
C O
O
LI
N G
T E
M P
E R
A T
U R
E
H U
M
ID
IT
Y
R A
C K
S E
N S
O R
S P
A C
E
AREA
WIDTH
(FT)
LENGTH
(FT)
HT TO
CLG
STRUCT REMARKS
BASEMENT
001 TELECOM ROOM X X X X X X X X X X 90 SF 7.5 11.9 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM ROOM
STANDARDS. SEE TELECOM DRAWINGS
FIRST FLOOR
139 EXIST RM 41 SF 3.7 11.1 9.33 DECOMMISSION EXIST IT/DATA ROOM. SEE TELECOM
DRAWINGS RELOCATE FUNCTIONS TO ROOM 001
SECOND FLOOR
241 EXIST RM 41 SF 3.7 11.1 9.33 DECOMMISSION EXIST IT/DATA ROOM. SEE TELECOM
DRAWINGS RELOCATE FUNCTIONS TO ROOM 001
OPENING SCHEDULE
VA Building Number
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
HAZARDOUS MATERIAL SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
QUESTIONABLE HAZARDOUS
ELEMENT POSSIBLE ABATEMENT ACTION
BASEMENT 001 TELECOM ROOM FLAKING CEILING PAINT. ASBESTOS
CONTAINING PIPE INSULATION. SEE
49-HA-2A
REMOVE HAZARDOUS MATERIAL UNDER FULL CONTAINMENT - SCRAPE CEILING CLEAN
FIRST FLOOR 139 EXIST RM NONE. SEE 49-HA-3A NONE. ACM TO REMAIN UNDISTURBED
SECOND FLOOR 241 EXIST RM NONE. SEE 49-HA-4A NONE. ACM TO REMAIN UNDISTURBED
HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT
DISTURB QUESTIONABLE HAZARDOUS MATERIAL.
LEAK PREVENTION / DIVERTER SCHEDULE
LEVEL
ROOM
NO. ROOM NAME OVERHEAD LEAK DIVERTER AND DRAIN PIPING LEAK PREVENTION BARRIER WATERPROOFING
BASEMENT 001 TELECOM ROOM MWP INT: NORTH
FIRST FLOOR 139 EXIST RM
SECOND FLOOR 241 EXIST RM
SEE GENERAL NOTES SHEET FOR DETAIL. MWP = MEMBRANE WATERPROOFING. MASONRY = FLUID-APPLIED WATERPROOFING. INT = INTERIOR. EXT = EXTERIOR
ICRA PHASE CONSTRUCTION ROOM SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
CAI BLDG NAME /
FUNCTION
CONSTRUCTION
PROJECT ACTIVITY
INFECTION CONTROL
RISK GROUP
CONTROL
PROCEDURE CLASS SECTION
CONSTRUCTION ZONE /
OCCUPIED CONSTR
DAY /
NIGHT
BASEMENT 001 TELECOM ROOM EXTENDED CARE TYPE C GROUP 1 CLASS II WEST OCCUPIED CONSTRUCTION DAY
FIRST FLOOR 139 EXIST RM EXTENDED CARE TYPE B GROUP 3 CLASS II WEST OCCUPIED CONSTRUCTION DAY
SECOND FLOOR 241 EXIST RM EXTENDED CARE TYPE B GROUP 3 CLASS II WEST OCCUPIED CONSTRUCTION DAY
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
X
T A B L E
C A B
IN
E T
S H R E D
R E C Y C L E
T R A S H
SHRED
R E C Y C L E
TRASH
C A B
IN
E T
C O P
IE
R
COPIER
42"
CABINET
F
F
IL
E
F
IL
E
B O
O K
S x D
E S
K x D
E S
K
S H
E L V
IN
G c ra w ls p a c e h a tc h
30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K x D
E S
K
30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K
30x48 DESK
30x48 DESK x D
E S
K x D
E S
K
30x48 DESK
48x48
TABLE
STAIR
HALL
BATH
RECORDS
STORAGE
OFFICE
OFFICE
14A
OFFICE
14B
UNIT DOSE
PHARM
AFGE
AFGE
CWT
VOLUNTEER
SERVICE
OFFICE
11A
HAC
OFFICE
25A
ALCOVE
OFFICE
OFFICE
24 OFFICE
UPPER PART OF
SERVICE ROOM
FEMALE
LOCKER ROOM
EMPLOYEE
LOUNGE
2A
HOUSEKEEPING
STORAGE
SOILED LINEN
& GARBAGE
STAIR
HALL
FM
STORAGE
OFFICE
3A
STAIR
3B
HALL
STAIR
21A
26A
FEMALE
LOCKER
VOLUNTEER
SERVICE
9C
TOILET
9B
CLOSET
9A
CORRIDOR
C0C
CORRIDOR
C0SE
CORRIDOR
C0NE
MECH
3E
OFFICE
OFFICE
VENDOR
STORAGE
OFFICE
OFFICE
EXAM
TOILET
30A
SHOWER
30B
ELECTRIC
ELEV.
EQUIP.
DATA
CHASE
PATIENT
EFFECTS
TOILET
1B
TOILET
1A
STORAGE
9E
FOYER
OFFICE
3D
OFFICE
3C
LINEN
CHUTE
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
TELECOM
ROOM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:5 :4
A
M
49-GI101
BASEMENT FLOOR -
INFECTION CONTROL &
PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
BASEMENT 001 TELECOM ROOM EXTENDED CARE TYPE C GROUP 1 CLASS II
FIRST FLOOR 139 EXIST RM EXTENDED CARE TYPE B GROUP 3 CLASS II
SECOND FLOOR 241 EXIST RM EXTENDED CARE TYPE B GROUP 3 CLASS II
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
1/8" = 1'-0"
BASEMENT FLOOR - CONST BARRIER PLAN
N
0 8' 16'4'
-ASBESTOS-CONTAMINATED SOIL
CASTLE HILL ASSOCIATES, LLC.
N
S
W
E
BUILDING #49 - CRAWLSPACE FLOOR PLAN
LEGEND
-POSITIVE SAMPLE LOCATION
-SAMPLE LOCATION
-ASBESTOS-CONTAINING FIRE DOOR
-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)
-ASBESTOS-CONTAINING MASTIC UNDER CARPET
-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC UNDER CARPET
-ASBESTOS-CONTAINING 12"X12" FLOOR TILE AND MASTIC
-ASBESTOS-CONTAINING PIPE INSULATION (HORIZONTAL RUNS)
-ASBESTOS-CONTAINING VENT CAULK
UP
UP UP
UPUP
DN
-ASBESTOS-CONTAINING WALL WATERPROOFING
-ASBESTOS-CONTAINING LAY-IN CEILING PANELS
-ASBESTOS-CONTAINING SINK SOUND DEADENER
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND
BUILDING #49 - BASEMENT FLOOR PLAN
-ASBESTOS-CONTAINING DOOR CAULK
-ASBESTOS-CONTAINING DUCT SEAM CAULK
UP
DN
UP
DN
135B135B
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND BUILDING #49 - FIRST FLOOR PLAN
-ASBESTOS-CONTAINING DUCT SEAM CAULK
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
LEGEND
BUILDING #49 - SECOND FLOOR PLAN
X
T A B L E
C A B
IN
E T
S H R E D
R E C Y C L E
T R A S H
SHRED
R E C Y C L E
TRASH
C A B
IN
E T
C O P
IE
R
COPIER
42"
CABINET
F
F
IL
E
F
IL
E
B O
O K
S x D
E S
K x D
E S
K
S H
E L V
IN
G c ra w ls p a c e h a tc h
30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K x D
E S
K
30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K
30x48 DESK
30x48 DESK x D
E S
K x D
E S
K
30x48 DESK
48x48
TABLE
STAIR
HALL
BATH
RECORDS
STORAGE
OFFICE
OFFICE
14A
OFFICE
14B
UNIT DOSE
PHARM
AFGE
AFGE
CWT
VOLUNTEER
SERVICE
OFFICE
11A
HAC
OFFICE
25A
ALCOVE
OFFICE
OFFICE
24 OFFICE
UPPER PART OF
SERVICE ROOM
FEMALE
LOCKER ROOM
EMPLOYEE
LOUNGE
2A
HOUSEKEEPING
STORAGE
SOILED LINEN
& GARBAGE
STAIR
HALL
FM
STORAGE
OFFICE
3A
STAIR
3B
HALL
STAIR
21A
26A
FEMALE
LOCKER
VOLUNTEER
SERVICE
9C
TOILET
9B
CLOSET
9A
CORRIDOR
C0C
CORRIDOR
C0SE
CORRIDOR
C0NE
MECH
3E
OFFICE
OFFICE
VENDOR
STORAGE
OFFICE
OFFICE
EXAM
TOILET
30A
SHOWER
30B
ELECTRIC
ELEV.
EQUIP.
DATA
CHASE
PATIENT
EFFECTS
TOILET
1B
TOILET
1A
STORAGE
9E
FOYER
OFFICE
3D
OFFICE
3C
LINEN
CHUTE
TELECOM
ROOM7'
-6
11'-11 1/2"
49-AS100
TELECOM
ROOM
IN-03.01
4'-11 3/4" 1'-10" 5'-1 1/2"
TELECOM
ROOM
TELECOM
ROOM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:5 :3
A
M
49-AS100
BASEMENT PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
N
0 8' 16'4' 1/8" = 1'-0"
BASEMENT FLOOR - OVERALL PLAN
1/4" = 1'-0"
ENLARGED FLOOR PLAN
N
0 4' 8'2'
1/4" = 1'-0"
DEMOLITION PLAN
N
0 4' 8'2'
1/4" = 1'-0"
REFLECTED CEILING PLAN
N
0 4' 8'2'
FL1
RC1 RC2
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
DE23 PREPARE EXISTING PARTITION FOR LEAK PREVENTION BARRIER. SEE
FLOOR PLAN AND SHEET AS601
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL AT EXISTING
PARTITION. SEE AS601.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
DE1
DE1
FL3 FL22
FL3
FL20FL3
FL3
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
DE23
T ectonic Cop yright 2007
HSHLD
SLD UTLTY
BLANKET
CLEAN
B
A
DINING
143B
TOILET
122B
PAT. RM
122A
TOILET
123B
STOR
SOILED
UTILITY
TUB
ROOM
STAIR
CLEAN
LINEN
PAT. RM
136A
KITCHEN
SERVICE
NURSES
PRACT
S.W. OFFICE
STAIR
HALL
CLEAN
UTILITY
CARE WS
EQUIP
STOR
TOILET
149B
SHRD PAT
RM
149A
LAUNDRY
RM
TOILET
153B
TOILET
154B
2 BED
1 BED
STAIRS
161A
ALCOVE
2 BED
1622 BED
2 BED
2 BED
STOR
TOILET
166B
WARMER
EXAM
VESTIBULE
PAT RM
110A
STOR.
STORAGE
SOILED
UTILITY
133A
1 BED
1 BED
STAIRS
116A
2 BED
1 BED
ALCOVE
1 BED
1 BED
CORRIDOR
SOILED
UTILITY
PIPE
CHASE
126A
SHRD PAT
RM
154A
PIPE
CHASE
151A
STOR.
LOUNGE
CORRIDOR
C1CCORRIDOR
C1W
CLEAN
UTILITY
PATIENT
ROOM
127APATIENT
ROOM
126A
TOILET
127B
PATIENT
RM
153A
PAT
ROOM
123A
CORRIDOR
C1E
BREAKROOM
LIVING
ROOM
135A
TOILET
126B
TOILET
PATIENT
ROOM
132A
PATIENT
ROOM
133A
MED RM
ELEC
PATIENT
ROOM
134A
OFFICE
HAC
TOILET
110B
TOILET
TOILET
117B
TOILET
132B
TOILET
133B
TOILET
134B
CONF.
ROOM
MED
REC
102A
EQUIP
STOR
ALCOVE
DINING
135B
TOILET
PAT. RM
148A
TOILET
148B
PAT. RM
142A
TOILET
142B
TOILET
141B
PAT. RM
141A
PAT. RM
140APAT. RM
139A
TOILET
140B
TOILET
139B
TOILET
136B
NURSE
STATION
ELEC.
TUB RM
COMM
PAT. RM
166A
HAC
MED RM
TOILET
159B
STOR
LIV RM
143A
CORRIDOR
C1N
CORRIDOR
C1C
CG
CG
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
FAXCOPIER
LINEN
CHUTE
EXIST RM
3' -8
/2
11'-1 1/4"
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:5 :4
A
M
49-AS110
FIRST FLOOR - OVERALL PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
1/8" = 1'-0"
FIRST FLOOR - OVERALL PLAN
N
0 8' 16'4'
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
NURSE
BLNKT
TUB
STAIR
216A
OFFICE
273 STAIR
1 BED
EQUIP
STOR
SHARED
PAT. RM
249A
SOILED
UTILITY
TOILET
253B
TOILET
254B
1 BED
1 BED
STAIR
ALCOVE
2 BED
2 BED
2 BED
1 BED
STATION
STOR.
256PAT. RM
266A
WRMR
EXAM
CHASE
PIPE
CHASE
226A
STAIR
HALL
PAT. RM
236A
CORRIDOR
C2N
KITCHEN
PIPE
CHASE
255A
CORR
SHARED
PAT. RM
254A
CORRIDOR
C2C CORRIDOR
C2E
PAT. RM
253A
LIVING
ROOM
235A
PATIENT
ROOM
234A
PATIENT
ROOM
233A
PATIENT
ROOM
232A
PATIENT
ROOM
227A
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
ALCOVE
2 PATIENT
ROOM
PATIENT
ROOM
223A
2 PATIENT
ROOM
226A
SOILED
UTILITY
CLEAN
UTILITY
CLEAN
LINEN
TUB
ROOM
NURSE MGR
ROOM
PATIENT
ROOM
210A
MED
ROOM
TOILET
236B
PAT. RM
239A
TOILET
239B
PAT. RM
240A
PAT. RM
241A
PAT. RM
242A
TOILET
240B
TOILET
241B
TOILET
242B
PAT. RM
248A
TOILET
249B
TOILET
248B
NURSE
STATION
TOILET
LAUNDRY
MED RM
STOR.
HAC
TOILET
266B
BREAKROOM
ROOM
EQUIP
STOR
CORRIDOR
C2C
DINING
243B
LIV. RM.
243A
NURSE
STATION
CONF.
MED.
RECORDS
202A
STAFF
TOILET
243B
HAC
CG
CG
CG
CG HR
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL
FAX
COPIER
ELEC
244244
BLNKT
WRMR
ALCV
272272
WHLCHR
ALCOVE
276276
STAFF TLT
203203
WLCM BUS
CNTR
202202
TLT
R
H/C R/F
C J I/W
H.S.
PAT TLT
240B240B
PAT RM
241A241A
PAT RM
240A240A
B
B 2 B
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
LINEN
CHUTE
3' -8
/2
11'-1 1/4"
EXIST RM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -4
-R
E
M a rk fo rt
.r v t
/2
/2
:5 :4
A
M
49-AS120
SECOND FLOOR - OVERALL
PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
1/8" = 1'-0"
SECOND FLOOR - OVERALL PLAN
N
0 8' 16'4'
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
L4
X
T A B L E
C A B
IN
E T
S H R E D
R E C Y C L E
T R A S H
SHRED
R E C Y C L E
TRASH
C A B
IN
E T
C O P
IE
R
COPIER
42"
CABINET
F
DN
DN
F
IL
E
F
IL
E
B O
O K
S x D
E S
K x D
E S
K
S H
E L V
IN
G c ra w ls p a c e h a tc h
30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K x D
E S
K
30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K
30x48 DESK
30x48 DESK x D
E S
K x D
E S
K
30x48 DESK
48x48
TABLE
E P
E P
ELEVATOR
3A
OFFICE
3B
STAIR
UTILITY
SOILED
STORAGE
HOUSEKEEPING
STAIR MECH
UPPER
LOCKER
FEMALE
2A
LOUNGE
EMPLOYEE
9B
BATH
9A
CLOSET
SERVICE
VOLUNTEER
STAIR
PHARMACY
14B
OFFICE
MED STORAGE
14A
OFFICE
STORAGE
BATH
11A
OFFICE
OFFICE
C0NE
CORR
C0C
CORRIDOR
OFFICE
HAC
OFFICE
OFFICE
OFFICE
ALCOVE
21A
STAIR
STORAGE
VENDOR
OFFICE
OFFICE
OFFICE
OFFICE
C0SE
CORR
3E
MECH
OFFICE
OFFICE
EXAM
LOCKER
FEMALE30A
TOILET
30B
SHOWER
ELECTRIC
EQUIP.
ELEV.
DATA
CHASE
ELEVATOR
EFFECTS
PATIENT
PATHOLOGY
1B
TOILET
1A
TOILET
STORAGE
FM
9C
VOLUNTER
SERVICE
ROOM
MECHANICAL
7A
ROOM
ELECT.
8A
VOLTAGE
LOW
9E
STORAGE
3D
OFFICE
FOYER
3C
OFFICE
LINEN
CHUTE
30'-10 3_
38'-8 1_
LIMITS OF DATA CABLING DEMOLITION
49-TN300
E
E
E
E
E
E
"x
2"
"x 2"
12"x2"
"x
2"
12"x2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:2
P
M
49-TD100
BASEMENT FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
N
0 8' 16'4' 1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
SHEET NOTES:
1. RETAIN DATA CABLE: EXISTING DATA CABLE THROUGHOUT THIS AREA IS SUFFICIENT TO REMAIN. NEW
CABLING NOT REQUIRED. RETAIN EXISTING CABLING IN SERVICE.
yright 2007
HSHLD
SLD UTLTY
BLANKET
CLEAN
B
A
24x36
WARDROBE
24x36
WARDROBE
24x36
WARDROBE
24x36
WARDROBE
x
W A
R D
R O
B E x
W A
R D
R O
B E
Table
24x24
Table
24x24
Table
24x24
Table
24x24
DINING
143B
TOILET
122B
PAT. RM
122A
TOILET
123B
STOR
SOILED
UTILITY
TUB
ROOM
STAIR
CLEAN
LINEN
PAT. RM
136A
KITCHEN
SERVICE
NURSES
PRACT
S.W. OFFICE
STAIR
HALL
CLEAN
UTILITY
CARE WS
EQUIP
STOR
TOILET
149B
SHRD PAT
RM
149A
LAUNDRY
RM
TOILET
153B
TOILET
154B
2 BED
1 BED
STAIRS
161A
ALCOVE
2 BED
1622 BED
2 BED
2 BED
STOR
TOILET
166B
WARMER
EXAM
VESTIBULE
PAT RM
110A
STOR.
STORAGE
SOILED
UTILITY
133A
1 BED
1 BED
STAIRS
116A
2 BED
1 BED
ALCOVE
1 BED
1 BED
CORRIDOR
SOILED
UTILITY
PIPE
CHASE
126A
SHRD PAT
RM
154A
PIPE
CHASE
151A
DATA
STOR.
LOUNGE
CORRIDOR
C1CCORRIDOR
C1W
CLEAN
UTILITY
PATIENT
ROOM
127APATIENT
ROOM
126A
TOILET
127B
PATIENT
RM
153A
PAT
ROOM
123A
CORRIDOR
C1E
BREAKROOM
LIVING
ROOM
135A
TOILET
126B
TOILET
PATIENT
ROOM
132A
PATIENT
ROOM
133A
MED RM
ELEC
PATIENT
ROOM
134A
OFFICE
HAC
TOILET
110B
TOILET
TOILET
117B
TOILET
132B
TOILET
133B
TOILET
134B
CONF.
ROOM
MED
REC
102A
EQUIP
STOR
ALCOVE
DINING
135B
TOILET
PAT. RM
148A
TOILET
148B
PAT. RM
142A
TOILET
142B
TOILET
141B
PAT. RM
141A
PAT. RM
140APAT. RM
139A
TOILET
140B
TOILET
139B
TOILET
136B
NURSE
STATION
ELEC.
TUB RM
COMM
PAT. RM
166A
HAC
MED RM
TOILET
159B
STOR
LIV RM
143A
CORRIDOR
C1N
CORRIDOR
C1C
CG
CG
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
FAXCOPIER
LINEN
CHUTE
LIMITS OF DATA CABLING DEMOLITION
49-TN300
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
EE
E
E
E
E
E
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
12"x2"
12"x2" 12"x2"
"x
2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2" 12"x2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:2
P
M
49-TD110
FIRST FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
N
0 8' 16'4' 1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOM - DEMOLITION
SHEET NOTES:
X " G
D CD
AIR OUTAIR IN
C2WC2W
CORR
219219
CARE W.S.
217B217B
PAT TLT
C2WC2W
CORR
210B210B
PAT TLT
222B222B
PAT TLT
223B223B
PAT TLT
226B226B
PAT TLT
227B227B
PAT TLT
232B232B
PAT TLT
233B233B
PAT TLT
234B234B
PAT TLT
225225
TLT
222A222A
SHRD PAT
RM
206206
HAC
229229
CARE W.S.
220220
STOR
228228
EQUIP
STOR
C2WC2W
CORR
231231
ELEC
205205
BLNKT
WRMR
ALCV
FD
24x36
WARDROBE
24x36
WARDROBE
24x36
WARDROBE
24x36
WARDROBE
x
W A
R D
R O
B E x
W A
R D
R O
B E
216A
STAIR
STAIR
2 BED
2 BED
2 BED
ALCOVE
261A
STAIR
1 BED
STAIR
DATA
CHASE
235A
ROOM
LIVING
234A
ROOM
PATIENT
C2C
CORRIDOR
233A
ROOM
PATIENT
232A
ROOM
PATIENT
227A
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
LOUNGE
ROOM
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ALCOVE
ROOM
2 PATIENT
223A
ROOM
PATIENT
226A
ROOM
2 PATIENT
UTILITY
SOILED
UTILITY
CLEAN
LINEN
CLEAN
ROOM
TUB
ROOM
NURSE MGR
210A
ROOM
PATIENT
ROOM
MED
E01
ELEV.
E02
ELEV.
1 BED
1 BED
248A
ROOM
PATIENT
243A
ROOM
LIVING
243B
ROOM
DINING
259A
AREA
SITTING
266A
ROOM
PATIENT
ROOM
MED
ROOM
EXAM
OFFICE
ROOM
TUB
UTILITY
CLEAN
UTILITY
SOILED
253A
ROOM
PATIENT
235B
ROOM
DINING
202A
RECORDS
MED
ROOM
CONF.
254A
PAT. ROOM
SHARED
KITCHEN
253B
TOILET
PATIENT
254B
TOILET
PATIENT
259B
TOILET
PATIENT266B
TOILET
PATIENT
BRK ROOM
STAFF
STOR.
EQUIP
248B
TOILET
PATIENT
249B
TOILET
PATIENT
249A
PAT. ROOM
SHARED
LAUNDRY
HAC
COMM
STOR
STATION
NURSE
STATION
NURSE
STATION
NURSE
C2E
CORRIDOR
C2N
HALL
STOR
EQUIP
239B
TOILET
PATIENT
236A
ROOM
PATIENT
239A
ROOM
PATIENT
217B
AREA
SITTING
CG
CG
CG
CG HR
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL
FAX
COPIER
ELEC
244244
BLNKT
WRMR
ALCV
272272
WHLCHR
ALCOVE
276276
STAFF TLT
203203
WLCM BUS
CNTR
202202
TLT
R
H/C R/F
C J I/W
H.S.
PAT TLT
240B240B
PAT RM
241A241A
PAT RM
240A240A
B
B 2 B
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
LINEN
CHUTE
LAST UPDATED: 3-2-16
LIMITS OF DATA CABLING DEMOLITION
49-TN300
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
EE
E
E
E
E
E
12"x2"
12"x2"
12"x2"12"x2"
12"x2"
12"x2"
12"x2" 12"x2"
12"x2"
12"x2"
12"x2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:3
P
M
49-TD120
SECOND FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
N
0 8' 16'4' 1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOM - DEMOLITION
SHEET NOTES:
F
48x48
TABLE
ELEVATOR
3A
OFFICE
3B
STAIR
UTILITY
SOILED
STORAGE
HOUSEKEEPING
STAIR MECH
UPPER
LOCKER
FEMALE
2A
LOUNGE
EMPLOYEE
9B
BATH
9A
CLOSET
SERVICE
VOLUNTEER
STAIR
PHARMACY
14B
OFFICE
MED STORAGE
14A
OFFICE
STORAGE
BATH
11A
OFFICE
OFFICE
C0NE
CORR
C0C
CORRIDOR
OFFICE
HAC
OFFICE
OFFICE
OFFICE
ALCOVE
21A
STAIR
STORAGE
VENDOR
OFFICE
OFFICE
OFFICE
OFFICE
C0SE
CORR
3E
MECH
OFFICE
OFFICE
EXAM
LOCKER
FEMALE30A
TOILET
30B
SHOWER
ELECTRIC
EQUIP.
ELEV.
DATA
CHASE
ELEVATOR
EFFECTS
PATIENT
PATHOLOGY
1B
TOILET
1A
TOILET
STORAGE
FM
9C
VOLUNTER
SERVICE
ROOM
MECHANICAL
7A
ROOM
ELECT.
8A
VOLTAGE
LOW
9E
STORAGE
3D
OFFICE
FOYER
3C
OFFICE
LINEN
CHUTE
30'-10 3_
38'-8 1_
TELECOM ROOM
49-TN400
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 001
4"
C4 126"
"x
2"
12"x2"
"x
2"
"x 2"
12"x2"
E
E
E
E
E
E
4"
4"
"x
2"
4"
12"x2"
"x
2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:3
P
M
49-TN100
BASEMENT FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
N
0 8' 16'4' 1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
SHEET NOTES:
1. PROVIDE JUNCTION BOX TO CONNECT EXISTING FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO
THE NEW TELECOM ROOM.
2. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.
yright 2007
HSHLD
SLD UTLTY
BLANKET
CLEAN
B
A
DINING
143B
TOILET
122B
PAT. RM
122A
TOILET
123B
STOR
SOILED
UTILITY
TUB
ROOM
STAIR
CLEAN
LINEN
PAT. RM
136A
KITCHEN
SERVICE
NURSES
PRACT
S.W. OFFICE
STAIR
HALL
CLEAN
UTILITY
CARE WS
EQUIP
STOR
TOILET
149B
SHRD PAT
RM
149A
LAUNDRY
RM
TOILET
153B
TOILET
154B
2 BED
1 BED
STAIRS
161A
ALCOVE
2 BED
1622 BED
2 BED
2 BED
STOR
TOILET
166B
WARMER
EXAM
VESTIBULE
PAT RM
110A
STOR.
STORAGE
SOILED
UTILITY
133A
1 BED
1 BED
STAIRS
116A
2 BED
1 BED
ALCOVE
1 BED
1 BED
CORRIDOR
SOILED
UTILITY
PIPE
CHASE
126A
SHRD PAT
RM
154A
PIPE
CHASE
151A
DATA
STOR.
LOUNGE
CORRIDOR
C1CCORRIDOR
C1W
CLEAN
UTILITY
PATIENT
ROOM
127APATIENT
ROOM
126A
TOILET
127B
PATIENT
RM
153A
PAT
ROOM
123A
CORRIDOR
C1E
BREAKROOM
LIVING
ROOM
135A
TOILET
126B
TOILET
PATIENT
ROOM
132A
PATIENT
ROOM
133A
MED RM
ELEC
PATIENT
ROOM
134A
OFFICE
HAC
TOILET
110B
TOILET
TOILET
117B
TOILET
132B
TOILET
133B
TOILET
134B
CONF.
ROOM
MED
REC
102A
EQUIP
STOR
ALCOVE
DINING
135B
TOILET
PAT. RM
148A
TOILET
148B
PAT. RM
142A
TOILET
142B
TOILET
141B
PAT. RM
141A
PAT. RM
140A
PAT. RM
139A
TOILET
140B
TOILET
139B
TOILET
136B
NURSE
STATION
ELEC.
TUB RM
COMM
PAT. RM
166A
HAC
MED RM
TOILET
159B
STOR
LIV RM
143A
CORRIDOR
C1N
CORRIDOR
C1C
CG
CG
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
FAXCOPIER
LINEN
CHUTE
T ectonic Cop yright 2007
HSHLD
SLD UTLTY
BLANKET
CLEAN
B
A
DINING
143B
TOILET
122B
PAT. RM
122A
TOILET
123B
STOR
SOILED
UTILITY
TUB
ROOM
STAIR
CLEAN
LINEN
PAT. RM
136A
KITCHEN
SERVICE
NURSES
PRACT
S.W. OFFICE
STAIR
HALL
CLEAN
UTILITY
CARE WS
EQUIP
STOR
TOILET
149B
SHRD PAT
RM
149A
LAUNDRY
RM
TOILET
153B
TOILET
154B
2 BED
1 BED
STAIRS
161A
ALCOVE
2 BED
1622 BED
2 BED
2 BED
STOR
TOILET
166B
WARMER
EXAM
VESTIBULE
PAT RM
110A
STOR.
STORAGE
SOILED
UTILITY
133A
1 BED
1 BED
STAIRS
116A
2 BED
1 BED
ALCOVE
1 BED
1 BED
CORRIDOR
SOILED
UTILITY
PIPE
CHASE
126A
SHRD PAT
RM
154A
PIPE
CHASE
151A
DATA
STOR.
LOUNGE
CORRIDOR
C1CCORRIDOR
C1W
CLEAN
UTILITY
PATIENT
ROOM
127APATIENT
ROOM
126A
TOILET
127B
PATIENT
RM
153A
PAT
ROOM
123A
CORRIDOR
C1E
BREAKROOM
LIVING
ROOM
135A
TOILET
126B
TOILET
PATIENT
ROOM
132A
PATIENT
ROOM
133A
MED RM
ELEC
PATIENT
ROOM
134A
OFFICE
HAC
TOILET
110B
TOILET
TOILET
117B
TOILET
132B
TOILET
133B
TOILET
134B
CONF.
ROOM
MED
REC
102A
EQUIP
STOR
ALCOVE
DINING
135B
TOILET
PAT. RM
148A
TOILET
148B
PAT. RM
142A
TOILET
142B
TOILET
141B
PAT. RM
141A
PAT. RM
140A
PAT. RM
139A
TOILET
140B
TOILET
139B
TOILET
136B
NURSE
STATION
ELEC.
TUB RM
COMM
PAT. RM
166A
HAC
MED RM
TOILET
159B
STOR
LIV RM
143A
CORRIDOR
C1N
CORRIDOR
C1C
CG
CG
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
FAXCOPIER
LINEN
CHUTE
EXIST RM
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 139
"x
2"
12"x2"
"x
2"
"x 2"
12"x2"
E
E
E
E
E
E
E
E
EE
E
E
E
E
E
EE
E
E
E
E
E
12"x2"
"x
2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
F2 12"x2"
"x
2"
"x
2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:3
P
M
49-TN110
FIRST FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
N
0 8' 16'4'
1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOMMUNICATIONS
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE
NURSE
BLNKT
TUB
STAIR
216A
OFFICE
273 STAIR
1 BED
EQUIP
STOR
SHARED
PAT. RM
249A
SOILED
UTILITY
TOILET
253B
TOILET
254B
1 BED
1 BED
STAIR
ALCOVE
2 BED
2 BED
2 BED
1 BED
STATION
STOR.
256PAT. RM
266A
WRMR
EXAM
DATA
CHASE
PIPE
CHASE
226A
STAIR
HALL
PAT. RM
236A
CORRIDOR
C2N
KITCHEN
PIPE
CHASE
255A
CORR
SHARED
PAT. RM
254A
CORRIDOR
C2C CORRIDOR
C2E
PAT. RM
253A
LIVING
ROOM
235A
PATIENT
ROOM
234A
PATIENT
ROOM
233A
PATIENT
ROOM
232A
PATIENT
ROOM
227A
PATIENT
ROOM
PATIENT
ROOM
LOUNGE
PATIENT
ROOM
PATIENT
ROOM
PATIENT
ROOM
ALCOVE
2 PATIENT
ROOM
PATIENT
ROOM
223A
2 PATIENT
ROOM
226A
SOILED
UTILITY
CLEAN
UTILITY
CLEAN
LINEN
TUB
ROOM
NURSE MGR
ROOM
PATIENT
ROOM
210A
MED
ROOM
TOILET
236B
PAT. RM
239A
TOILET
239B
PAT. RM
240A
PAT. RM
241A
PAT. RM
242A
TOILET
240B
TOILET
241B
TOILET
242B
PAT. RM
248A
TOILET
249B
TOILET
248B
NURSE
STATION
TOILET
LAUNDRY
MED RM
STOR.
HAC
TOILET
266B
BREAKROOM
ROOM
EQUIP
STOR
CORRIDOR
C2C
DINING
243B
LIV. RM.
243A
NURSE
STATION
CONF.
MED.
RECORDS
202A
STAFF
TOILET
243B
HAC
CG
CG
CG
CG HR
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL
FAX
COPIER
ELEC
244244
BLNKT
WRMR
ALCV
272272
WHLCHR
ALCOVE
276276
STAFF TLT
203203
WLCM BUS
CNTR
202202
TLT
R
H/C R/F
C J I/W
H.S.
PAT TLT
240B240B
PAT RM
241A241A
PAT RM
240A240A
B
B 2 B
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
LINEN
CHUTE
LAST UPDATED: 3-2-16
EXIST RM
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 241
"x
2"
12"x2"
"x
2"
"x 2"
12"x2"
E
E
E
E
E
E
E
E
E E
E
E
E
E
E
EE
E
E
E
E
E
12"x2"
"x
2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
12"x2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
"x
2"
12" LADDER
12"x2"
"x
2"
F2
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:3
P
M
49-TN120
SECOND FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
N
0 8' 16'4'
1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOMMUNICATIONS
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE
F
4 8 x 4 8
TA B L E
ELE VATOR
3A
OFFICE
3B
STAIR
UTILITY
SOILED
STORAGE
HOUSEKEEPING
STAIR MECH
UPPER
LOCKER
FEMALE
2A
LOUNGE
EMPLOYEE
9B
BATH
9A
CLOSET
SERVICE
VOLUNTEER
STAIR
PHARMACY
14B
OFFICE
MED STORAGE
14A
OFFICE
STORAGE
BATH
11A
OFFICE
OFFICE
C0NE
CORR
C0C
CORRIDOR
OFFICE
HAC
OFFICE
OFFICE
OFFICE
ALCOVE
21A
STAIR
STORAGE
VENDOR
OFFICE
OFFICE
OFFICE
OFFICE
C0SE
CORR
3E
MECH
OFFICE
OFFICE
EXAM
LOCKER
FEMALE30A
TOILET
30B
SHOWER
ELECTRIC
EQUIP.
ELEV.
DATA
CHASE
ELE VATOR
EFFECTS
PATIENT
PATHOLOGY
1B
TOILET
1A
TOILET
STORAGE
FM
9C
VOLUNTER
SERVICE
ROOM
MECHANICAL
7A
ROOM
ELECT.
8A
VOLTAGE
LOW
9E
STORAGE
3D
OFFICE
FOYER
3C
OFFICE
LINEN
CHUTE
30'-10 3_
38'-8 1_
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:3
P
M
49-TN200
BASEMENT FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 30' 60'15' 1" = 30'-0"
BASEMENT FLOOR PLAN - TELECOM - CABLE DISTANCE
PATIENT
PATHOLOGY
DATA
CG
DATA
ELEV.
BRK ROOM
STAFF
CG
CG
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:3
P
M
49-TN300
ENLARGED PLANS
-TELECOMMUNICATIONS -
DEMO
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
0 4' 8'2'
N
N
0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 139
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 312
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
2. ROOM 241
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 99
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
1/4" = 1'-0"
ENLARGED PLAN -EXIST TR 001 - TELECOM - DEMO
1/4" = 1'-0"
ENLARGED PLAN -EXIST TR 139 - TELECOM - DEMO
N
0 4' 8'2' 1/4" = 1'-0"
ENLARGED PLAN -EXIST TR 241 - TELECOM - DEMO
SHEET NOTES:
1. EXISTING CABLE TRAY, SECURITY CAMERAS, GROUND BUS BARS, AND RACKS FROM DECOMMISSIONED
ROOMS ARE TO BE REUSED, WHEN POSSBILE, IN NEW CONSTRUCTION TRS.
A C
C R
C
PATIENT
PATHOLOGY
49-TN400
1 - a b
1 - c d
CABLE TRAY
DATA RACK
C4 126"
4"
12"x4"
12"x4"
"x
4"
"x
4"
"x
4"
W KEYPAD
12"x2"
"x
2"
AC
NOTES:
1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.
4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO
SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).
5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER
ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.
7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.
VERTICAL CABLE
MANAGEMENT (TYP)
RACK 1
1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT5E BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
CHANNEL RACK (TYP)
D
PROVIDE DATA CABLE TO RACK
MOUNTED UPS FOR CONNECTION
TO MONITORING SYSTEM
RACK 1
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
D
RACK 2
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
RACK 2
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:4
P
M
49-TN400
ENLARGED PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/2" = 1'-0"
ENLARGED PLAN - TR 001 - TELECOM - CABLE TRAY AND DATA
1/4" = 1'-0"
1 - a
1/4" = 1'-0"
1 - b
1/4" = 1'-0"
1 - c
1/4" = 1'-0"
1 - d
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
1. ROOM 001
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 312 FROM ROOM 139, 99 FROM 241
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6A): 411
DATA (CAT6): 0
N
0 2' 4'1'
NOT TO SCALE
COMMUNICATIONS - TYPICAL TWO RACK ELEVATION WITH RACK MOUNT UPS - TR 001
SHEET NOTES:
1. IF NO ACCESS CONTROL PANEL IS PRESENT IN THE TR, PROVIDE A NEW ACCESS CONTROL PANEL TO BE INSTALLED IN THE TELECOM ROOM. THE CARD READER AND KEYPAD FOR THIS ROOM TO BE WIRED TO THE NEW ACCESS CONTROL PANEL. EXISTING CARD READERS AND KEYPADS WILL BE MOVED TO THE NEW
CONTROL PANEL UNDER A DIFFERENT PROJECT.
X
T A B L E
C A B
IN
E T
S H R E D
R E C Y C L E
T R A S H
SHRED
R E C Y C L E
TRASH
C A B
IN
E T
C O P
IE
R
COPIER
42"
CABINET
F
F
IL
E
F
IL
E
B O
O K
S x D
E S
K x D
E S
K
S H
E L V
IN
G c ra w ls p a c e h a tc h
30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K x D
E S
K
30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK 30x48 DESK
30x48 DESK 30x48 DESK x D
E S
K x D
E S
K x D
E S
K
30x48 DESK
30x48 DESK x D
E S
K x D
E S
K
30x48 DESK
48x48
TABLE
STAIR
HALL
BATH
RECORDS
STORAGE
OFFICE
OFFICE
14A
OFFICE
14B
UNIT DOSE
PHARM
AFGE
AFGE
CWT
VOLUNTEER
SERVICE
OFFICE
11A
HAC
OFFICE
25A
ALCOVE
OFFICE
OFFICE
24 OFFICE
UPPER PART OF
SERVICE ROOM
FEMALE
LOCKER ROOM
EMPLOYEE
LOUNGE
2A
HOUSEKEEPING
STORAGE
SOILED LINEN
& GARBAGE
STAIR
HALL
FM
STORAGE
OFFICE
3A
STAIR
3B
HALL
STAIR
21A
26A
FEMALE
LOCKER
VOLUNTEER
SERVICE
9C
TOILET
9B
CLOSET
9A
CORRIDOR
C0C
CORRIDOR
C0SE
CORRIDOR
C0NE
MECH
3E
OFFICE
OFFICE
VENDOR
STORAGE
OFFICE
OFFICE
EXAM
TOILET
30A
SHOWER
30B
ELECTRIC
ELEV.
EQUIP.
DATA
CHASE
PATHOLOGY
PATIENT
EFFECTS
TOILET
1B
TOILET
1A
STORAGE
9E
FOYER
OFFICE
3D
OFFICE
3C
LINEN
CHUTE
30'-10 3_
38'-8 1_
TELECOM
ROOM
49-E300
49-E300
49-E300
49-MSB
49-MDP
49-ECB-2
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:0
A
M
49-E200
BASEMENT - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
BASEMENT - ELECTRICAL
N
0 8' 16'4'
100% CD 03/30
E ectonic Cop yright 2007
HSHLD
SLD UTLTY
BLANKET
CLEAN
B
A
DINING
143B
TOILET
122B
PAT. RM
122A
TOILET
123B
STOR
SOILED
UTILITY
TUB
ROOM
STAIR
CLEAN
LINEN
PAT. RM
136A
KITCHEN
SERVICE
NURSES
PRACT
S.W. OFFICE
STAIR
HALL
CLEAN
UTILITY
CARE WS
EQUIP
STOR
TOILET
149B
SHRD PAT
RM
149A
LAUNDRY
RM
TOILET
153B
TOILET
154B
2 BED
1 BED
STAIRS
161A
ALCOVE
2 BED
1622 BED
2 BED
2 BED
STOR
TOILET
166B
WARMER
EXAM
VESTIBULE
PAT RM
110A
STOR.
STORAGE
SOILED
UTILITY
133A
1 BED
1 BED
STAIRS
116A
2 BED
1 BED
ALCOVE
1 BED
1 BED
CORRIDOR
SOILED
UTILITY
PIPE
CHASE
126A
SHRD PAT
RM
154A
PIPE
CHASE
151A
DATA
STOR.
LOUNGE
CORRIDOR
C1CCORRIDOR
C1W
CLEAN
UTILITY
PATIENT
ROOM
127APATIENT
ROOM
126A
TOILET
127B
PATIENT
RM
153A
PAT
ROOM
123A
CORRIDOR
C1E
BREAKROOM
LIVING
ROOM
135A
TOILET
126B
TOILET
PATIENT
ROOM
132A
PATIENT
ROOM
133A
MED RM
ELEC
PATIENT
ROOM
134A
OFFICE
HAC
TOILET
110B
TOILET
TOILET
117B
TOILET
132B
TOILET
133B
TOILET
134B
CONF.
ROOM
MED
REC
102A
EQUIP
STOR
ALCOVE
DINING
135B
TOILET
PAT. RM
148A
TOILET
148B
PAT. RM
142A
TOILET
142B
TOILET
141B
PAT. RM
141A
PAT. RM
140APAT. RM
139A
TOILET
140B
TOILET
139B
TOILET
136B
NURSE
STATION
ELEC.
TUB RM
COMM
PAT. RM
166A
HAC
MED RM
TOILET
159B
STOR
LIV RM
143A
CORRIDOR
C1N
CORRIDOR
C1C
CG
CG
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL HEADWALL HEADWALL
HEADWALL
HEADWALL
HEADWALL
HEADWALL
LIGHT
LIGHT
LIGHT
LIGHT
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
H E
A D
W A
L L
H E
A D
W A
L L
L
IG
H T
L
IG
H T
LIGHT
FAXCOPIER
LINEN
CHUTE
EXIST RM
B49IT-1-CR-8
WP
CU-49-1
B49IT-1-CR-5,7
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:0
A
M
49-E201
FIRST FLOOR - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
N
0 8' 16'4' 1/8" = 1'-0"
FIRST FLOOR - ELECTRICAL
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
PATIENT
PATHOLOGY
1B 1A
PATHOLOGY
PATIENT
EFFECTS
1B
SD
E
PATHOLOGY
PATIENT
EFFECTS
1B
TELECOM
ROOM
A
B49IT-1-CR
b
A
B49IT-1
a a b
TELECOM
ROOM
B49IT-1
B49IT-1-CR
B49IT-1-CR-1B49IT-1-1
B49IT-1-CR-1
B49IT-1-1 B49IT-1-CR-1
B49IT-1-2,4,6
B49IT-1-CR-2,4,6
4 5
6 7
AC-49-1
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:0
A
M
49-E300
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
SHEET NOTES:
1. REFER TO TECHNOLOGY PLANS FOR IT ROOM
LAYOUT AND RACK LAYOUT/DETAILS.
2. REFER TO SHEET 0-GE400 DETAIL LAYOUT &
ONE-LINE OF RACK.
KEYNOTES:
1. DISCONNECT AND REMOVE LIGHTS AND
RECEPTACLES IN AREA OF NEW IT ROOM.
MAINTAIN CIRCUIT CONTINUITY TO ADJOINING
SPACES.
2. INDOOR UNIT TO BE POWERED BY OUTDOOR
UNIT. COORDINATE EXACT LOCATION WITH
M.C.
3. CONNECT SMOKE DETECTOR TO NEAREST
EXISTING SLC.
4. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-30R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#10, 1#10 GND
TO PANEL FOR EACH RECEPTACLE.
5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-
PHASE, 4-WIRE RACK MOUNTED UPS FOR
EACH RACK TOWER.
6. PROVIDE APC#AP8861 RPDU RACK PDU 2G
WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,
ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R
OUTLETS. PROVIDE TWO PER RACK, MOUNTED
PER MANUFACTURER'S REQUIREMENTS.
7. PROVIDE ONE RACK MOUNTED ZONE PDU
UNIT. 30 AMP 3 PHASE, 120/208V, 5-WIRE WITH
(4) L21-30R, (6) 5-20R AND TWO 10' POWER
CORDS. ZONIT#ZPDS-208V-30A-L21-4L21-20R-
CR.
N O R
HT
1/4" = 1'-0"
BASEMENT - ELECTRICAL DEMOLITION
N O R
HT
1/4" = 1'-0"
BASEMENT - LIGHTING - TR 001
N O R
HT
1/4" = 1'-0"
BASEMENT - POWER & SYSTEM - TR 001
B-9IT-1-CR
100Y
BASEMENT
FIRST FLOOR
B49IT-1
100Y
49-MDP 49ECB-2
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10