Atch 13 - BLDG 7 and 13 addendum.pdf
PDF 16 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
- Solicitation number
- 36C77622B0035
About this file
This document includes details for a federal solicitation seeking construction services. The solicitation seeks a contractor to perform infrastructure upgrades at the St. Cloud Veterans Affairs Health Care System, including electrical, bonding, UPS, building management systems, access security, HVAC assessments and upgrades, data center/server room physical security upgrades, fiber infrastructure installation and upgrades both within and between buildings, and hazardous materials abatement. The work must be completed in accordance with provided specifications and contract drawings. The soliciting agency is the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation number is 36C77622B0035 and is titled "Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud."
View the file
Other files for this federal contract opportunity
Show all 50
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND
CORRIDOR OUTLINE
VFY EXIST
BUILDING OUTLINE
VFY EXIST
TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST
44TH AVE.
TRAIL 1
TRAIL 2
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2)
15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
GRAVEL
GRAVEL
GRAVEL
EXISTING
ROAD
CHAIN LINK FENCE
CHAIN LINK FENCE
16' GATE
GRAVEL
ELECTRICAL
SUBSTATION
G E N E R A T O R
FUEL LINES
CONDU ITS TO TU NNEL
M V
D U
C T
B A
N K
1 1 2 W
PHARMACY ADDITION
11 2 E
G E N E R A T O R
B
CORRIDOR LINK
A
C T
TR
A
IL
ER
174 s .f.
256 s .f.
185 s .f.
149 s ..f.
155 s .f.
104 s .f.
70 s. .f .
72 s .f.
110 s .f.
276 s .f.
112 s .f.
99 s .f.
57 s .f.
146 s .f.
434 s .f.
R A
MP
U P
1:
M A X
R A
MP
U P
1:
M A X
RA
M P
UP
1:2 0 M
AX
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2) 15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
.3
TRANSFORMER
BUILD ING
#91
5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN
O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW
C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D
P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S
R EC O M M EN D ATIO N S
N EW G AS SU P P LY M AIN
IN TO B U ILD IN G
SP AR E
P H O N E LIN E
EXTEN D S TO
E XISTIN G
P H O N E IN
B O ILER R O O M
P ER P LAN .
SP AR E
P H O N E
LIN E TO
M ETER
TU N N EL
E XTEN D S
A D D ITIO N AL
2'- 0" U N D ER
B U ILD IN G
FUEL LINE
VENT LINE
1,000 GAL.
UNDERGROUND
DIESEL FUEL
TANK
1,000/5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
S 1
LIG H T
N EW G AS SU P P LY
(C O O R D IN ATE W ITH SU P P LIER )
12"D
10"D
"D
TP TP
EXIST. BUILDING
EXIST.
BUS STOP
CC
L O
O P
16"
20"
12"
3"
8"
DN
0.
0’
BIRDCAGE
B
IR
D C
A G
E
NSP ELECTRICAL
FOR HWY DEPT
T101
I.T.
CHILLER
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
VESTIBULE
DN
DN
DN
FD
DN
F B
F
B
F B
F
B
F B
F
B
SOUTH
VESTIBULE
PASS
THROUGH
LINK TO
BUILDI NG 51
6 3. 32 56
1 13 5. 35 78
PARKING
NO
PARKING
93 49
37 6
6 107
109 5
1A
S M
O K
E B
L D
G
SMOKE
BLDG
SMOKE
BLDG
S M
O K
E B
L D
G
SMOKE
BLDG
M.H.
STOR.
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
STOR.
BIO-
HAZ.
SAUK RIVER
GP
HOLDING POND
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
SEE 54-GI000
SEE 54-GI000
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
OWNER AND
CONSULTANTS:
CONTACT:
ADDRESS:
MIKE ENGMARK
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
NAME:
ADDRESS:
CONTACT:
ADVANCED STRUCTURAL TECHNOLOGIES
7301 OHMS LANE; SUITE 215
EDINA, MN 55439
ZACHARY CRAIG
PHONE:
NAME:
ADDRESS:
CONTACT:
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
PHONE: 402-991-5520
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
IAN WEBER
763-412-4000
ARCHITECT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
EDWARD MARKFORT
763-412-4000
952-854-9302
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
402-991-5520
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
COVER
DATE:
APPROVED: APPROVED: PROJECTS SECTION MANAGER
APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:
APPROVED: SAFETY MANAGER
APPROVED: CHIEF OF POLICE
APPROVED: PATIENT SAFETY
DATE:
DATE:
DATE: APPROVED: EMS MANAGER
APPROVED: M/O MANAGER
DATE:
DATE:
DATE:DATE:
APPROVED: MEDICAL CENTER DIRECTOR
APPROVED: PROJECT COR DATE:
APPROVED: INFECTION CONTROL NURSE DATE:
APPROVED: SERVICE LINE DIRECTOR
APPROVED: GEMS COORDINATOR DATE:
DATE:
APPROVED: NURSE EXECUTIVE
APPROVED: CHIEF OF STAFF DATE:
APPROVED: DIRECTOR FMS
APPROVED: ASSOCIATE DIRECTOR
DATE:
DATE:
DATE:
DATE:APPROVED: DATE:
APPROVED: DATE:
APPROVED: DATE:
Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System
N
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
VICINITY MAP:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHONE: 320-252-1670
CIVIL ENGINEER:
VA COR:
TELECOMMUNICATIONS ENGINEER:
CONTACT:
ADDRESS:
JONATHAN WEST
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
PHONE: 504-250-2699
PROGRAM MANAGER:
EMAIL: Jonathan.West@vciint.com
STRUCTURAL ENGINEER:
MECH/ELEC/PLUMB/FIRE ENGINEER:
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -7
-R E
M a rk fo rt
.r v t
/2
/2
:1
:0
P
M
7-GI000
BUILDINGS 7 & 13 COVER
SHEET & SHEET INDEX
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
BUILDINGS 7 AND 13 - EHRM INFRASTRUCTURE UPGRADES
7 & 13
03/30/2022
0APPROX 150' 300'75'
SHEET INDEX - BUILDING 7 & 13
SHEET NO. SHEET TITLE
7-GI000 BUILDINGS 7 & 13 COVER SHEET & SHEET INDEX
7-GI001 FIRST FLOOR LIFE SAFETY PLAN
7-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN
7-HA-1A REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY
7-HA-2A REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY
13-HA-1A REFERENCE - FIRST FLOOR - ASBESTOS RE-SURVEY
7-AS110 FIRST FLOOR PLANS
7-S110 FIRST FLOOR PLANS
7-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION
7-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS
7-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
7-TN300 ENLARGED PLANS - TELECOMMUNICATIONS - DEMO
7-TN400 ENLARGED PLANS - TELECOMMUNICATIONS
07-E100 FIRST FLOOR DEMOLITION PLAN - ELECTRICAL
07-E200 FIRST FLOOR PLAN - ELECTRICAL
07-E300 ELECTRICAL ENLARGED PLANS
07-E500 ELECTRICAL ONE-LINE DIAGRAMS
07-E600 ELECTRICAL SCHEDULES
07-M101 FIRST FLOOR DEMOLITION - MECHANICAL
07-M201 FIRST FLOOR REMODEL - MECHANICAL
SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
1" = 50'-0"
KEY PLAN
ROOM SCHEDULE
NO. NAME C
A
B
LI
N G
P A
T C
H P
A N
E L
F
IB
E R
P O
W E
R
B O
N D
IN
G
U P
S
D E
D
IC
A T
E D
C O
O
LI
N G
T E
M P
E R
A T
U R
E
H U
M
ID
IT
Y
R A
C K
S E
N S
O R
S P
A C
E
AREA
WIDTH
(FT)
LENGTH
(FT)
HT TO
CLG
STRUCT REMARKS
FIRST FLOOR
102A TELECOM ROOM X X X X X X X X X X X 103 SF 7.0 14.7 10'-0" CONSTRUCT TO EHRM TELECOM ROOM STANDARDS.
SEE TELECOM DRAWINGS. CMU PARTITION BLOCK
INFILL WINDOWS. INFILL ROOF SMOKE VENTS. FLOOR
DRAIN.
FIRST FLOOR
PLACEHOLDER
BUILDING 13
12 SF SEE BUILDING 7 FOR TELECOM ROOM. SEE
TELECOMMUNICATION DRAWINGS
OPENING SCHEDULE
VA Building Number
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
7 TELECOM ROOM 102A 3'-0" 7'-0" HM-FS NONE HMM-1S NONE HW-3.2 45 Y Y Y
HAZARDOUS MATERIAL SCHEDULE
BUILDING
ROOM
NO. ROOM NAME
QUESTIONABLE HAZARDOUS
ELEMENT POSSIBLE ABATEMENT ACTION
FIRST FLOOR
7 102A TELECOM ROOM ASBESTOS - CONTAINING PIPE
INSULATION. SEE 7-HA-1A
NONE. PIPE INSULATION TO REMAIN UNDISTURBED
13 PLACEHOLDER
BUILDING 13
ACM. SEE 13-HA-1A NONE. MATERIAL TO REMAIN UNDISTURBED
HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT
DISTURB QUESTIONABLE HAZARDOUS MATERIAL.
ICRA PHASE CONSTRUCTION ROOM SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
CAI BLDG NAME /
FUNCTION
CONSTRUCTION
PROJECT ACTIVITY
INFECTION CONTROL
RISK GROUP
CONTROL
PROCEDURE CLASS SECTION
CONSTRUCTION ZONE /
OCCUPIED CONSTR
DAY /
NIGHT
FIRST FLOOR 102A TELECOM ROOM BOILERHOUSE TYPE D GROUP 1 CLASS III/IV CENTER ZONE7 DAY
FIRST FLOOR PLACEHOLDER
BUILDING 13
FACILITIES OFFICE CENTER OCCUPIED CONSTRUCTION DAY
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
1 UPDATE TO BID DOCUMENTS 06/29/22
536 175
1082 170
STORAGE
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
TELECOM
ROOM
TRAVEL DISTANCE
42'-0"
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
EDEXIT EXIT
HORIZONTAL EXIT
EXIT DISCHARGE
EXIT ACCESS
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
SMOKE
COMPARTMENT
BOUNDARY
HEALTH CARE
SUITE
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
OCCUPANCY
SEPARATION
SHAFT
ADJACENT SYMBOLS SHOW PARTITION RATING AND
DAMPER REQUIREMENTS
HAZARDOUS USE
ADJACENT SYMBOLS SHOW PARTITION RATING.
OPENINGS REQUIRE CLOSER & LATCH
EXIT PASSAGEWAY
RATE AS STAIR
ALL OPENINGS TO BE RATED AS STAIR SHAFT
CORRIDOR
WALLS TO LIMIT THE TRANSFER OF SMOKE
ADJUNCT CORRIDOR or PSYCHIATRIC AREA or CONSTRUCTED WITH MIN. 4'-0" CLEAR
WITH (PER CHAPTER 19)
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -7
-R E
M a rk fo rt
.r v t
/2
/2
:2 :4
P
M
7-GI001
FIRST FLOOR LIFE SAFETY
PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
7 & 13
03/30/2022
3/32" = 1'-0"
FIRST LEVEL LIFE SAFETY PLAN
N
0 8' 16'4'
536 175
1082 170
STORAGE
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
E
101 102
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
102A
TELECOM
ROOM
PLACEHOLDER
BUILDING 13
BUILDING 13
BUILDING 7
ZONE 7
CONSTRUCTION / ICRA BARRIER
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -7
-R E
M a rk fo rt
.r v t
/2
/2
:2 :1
P
M
7-GI111
FIRST FLOOR - INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
7 & 13
03/30/2022
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
FIRST FLOOR 102A TELECOM ROOM BOILERHOUSE TYPE D GROUP 1 CLASS III/IV
FIRST FLOOR PLACEHOLDER
BUILDING 13
FACILITIES OFFICE
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
1/8" = 1'-0"
FIRST FLOOR - CONST BARRIER PLAN
-ASBESTOS-CONTAINING PIPE TAR/COATING
-ASBESTOS-CONTAINING PIPE INSULATION DEBRIS
-ASBESTOS-CONTAINING SINK UNDERCOATING
-ASBESTOS-CONTAINING PIPE INSULATION
CASTLE HILL ASSOCIATES, LLC.
N S
W E
BUILDING #7 - FIRST FLOOR PLAN
-ASBESTOS-CONTAINING WINDOW GLAZING
CASTLE HILL ASSOCIATES, LLC.
N S
W E
BUILDING #7 - SECOND FLOOR PLAN
-ASBESTOS-CONTAINING WINDOW GLAZING
-ASBESTOS-CONTAINING PIPE INSULATION IN SUB-FLOOR PIT
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
BUILDING #13 - FIRST FLOOR PLAN
STORAGE
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
101 102
102A
TELECOM
ROOM
PLACEHOLDER
BUILDING 13
7' -0
/8
14'-8 3/8"
7-AS110
BUILDING 13
BUILDING 7
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
SEE 54-GI000
SEE 54-GI000
102A
TELECOM
ROOM
MA8
MA8
2A
IN-03.01
7-AS110
S
LO
P E
D
SLOPE
DN
S
LO
P E
D N
SLOPE
DN
4'-0" 2'-6" 6'-8" 2'-6"
6' -4
2'
-6
8'-1" 7'-6"
8' -2
7' -4
/4
V
F Y
15'-0 1/4", VFY
TELECOM
ROOM
CMU BLOCK INFILL
EXTERIOR INTERIOR
102A
TELECOM
ROOM
BRINE
ROOM
MA8
ROOF CAPPED CURB
OVERHEAD LEAK DIVERTER,
SEE MECHANICAL
FIRE RATED PLYWOOD,
FINISH
FLUID-APPLIED
WATERPROOFING
4" HOUSEKEEPING PAD
6" CONCRETE SLAB,
SLOPE TO FLOOR DRAIN.
SEE STRUCT & MECH
7-AS110
7-AS110
SLOPE
2"
3"
ONE PIECE STAINLESS
STEEL CURB CAP
FLASHING WITH
INTEGRAL DRIP EDGE -
WELD ALL SEAMS &
JOINTS WATERTIGHT -
SECURE WITH RUBBER
WASHERED
FASTENERS (TWO PER
SIDE MINIMUM)
ANGLE CLOSURES AT
DECK ENDS
SELF-ADHERED
UNDERLAYMENT
RIGID INSULATION,
PROVIDE TAPERED
INSULATION TO
MINIMUM 1/4" PER
FOOT SLOPE
COVER BOARD
EXISTING CURB
EXISTING ROOF
MEMBRANE
METAL DECK - SECURE
TO CURB AT 6" O.C.
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
100% CONSTRUCTION DOCUMENTS
FOR BID - NOT FOR CONSTRUCTION
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -7
-R E
M a rk fo rt
.r v t
/3
/2
:0
:2
P
M
7-AS110
FIRST FLOOR PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
7 & 13
N
0 8' 16'4'1/8" = 1'-0"
FIRST FLOOR PLAN
1" = 50'-0"
KEY PLAN
1/4" = 1'-0"
ENLARGED FLOOR PLAN
N
0 4' 8'2'
NN
N
N
1/4" = 1'-0"
PARTIAL DEMOLITION PLAN
N
0 8' 16'4'
N
N
0 4' 8'2'
N
1/4" = 1'-0"
REFLECTED CEILING PLAN
DE1
DE15
FL3
FL20
RC1 RC2
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
DE10 PREPARE FLOOR FOR FLOOR BUILDUP
DE15 REMOVE 30"X18" GLASS BLOCK WINDOW, PREPARE FOR INFILL
DE16 PREPARE ROOF MOUNTED PRESSURE RELIEF VENT FOR INFILL
DE33 PARTIALLY REMOVE FLOOR FOR FLOOR DRAIN
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL7 WALL INFILL, MATCH EXISTING CONSTRUCTION
FL8 FLOOR DRAIN, SEE MECHANICAL
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
FL21 OVERHEAD LEAK DIVERTER, SEE PLUMBING.
FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL,
SEE AS601
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
BRINE
ROOM
FL22
FL22
DE16
DE15
FL1_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED
SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM
ROOMS.
DE15
DE1
FL3
FL22
3/8" = 1'-0"
PARTIAL BUILDING SECTION - BUILDING 7 TELECOM ROOM 102A
3" = 1'-0"
SECTION DETAIL - ROOF CAPPED CURB
DE33DE10
FL8
ABOVE
DE16
ABOVE
FL7 FL7
FL7
FL21
1 UPDATE TO BID DOCUMENTS 06/29/22
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
102A
TELECOM
ROOM
S E
E A
R C
H
SEE ARCH.
INFILL WINDOWS WITH CMU
CMU PARTITION
7-S110
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
102A
TELECOM
ROOM S
E E
A R
C H
SEE ARCH.
MW2
M W
L1
S600
@ INFILL OPENINGS
NEW 6" HOUSEKEEPING PAD
7-S110
S500
NEW INTERIOR NON-LOAD
BEARING CMU PARTITION
DOWELS TO MATCH
SIZE AND SPACING
OF VERT. BARS
DRILL AND EPOXY INTO EXIST.
SOG. HILTI HY 200 EPOXY
ALL NEW REBAR IN BUILDING 7
SHALL BE EPOXY COATED OR
GALVANIZED FOR CORROSION
PROTECTION
1 1/2" MIN.
4" E
M B
E D
EXIST. SOG.
NEW 6"
HOUSEKEEPING PAD.
SEE 7/S500
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
7301 OHMS LANE
SUITE #215
(952) 854-9302 TEL.
EDINA, MN 55439
ASTENG.COM
AST PROJECT NUMBER: MN 1964
03/30/2022
ZDC JRO
656-21-235
EHRM INFRASTRUCTURE
UPGRADES
C U s e rs
\j o b ri e n \D o c u m e n ts
\1
-7
-R jo b ri e n
K Q
E N
.r v t
/2
/2
:4
:0
A
M
7-S110
FIRST FLOOR PLANS
16305
0 8' 16'4'1/8" = 1'-0"
FIRST FLOOR PLAN
1" = 50'-0"
KEY PLAN
3/8" = 1'-0"
ENLARGED FLOOR PLAN
N
N
N
N
N
SHEET NOTES:
1. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
ANY EXISTING CONDITIONS THAT DIFFER FROM THOSE SHOWN ON THE STRUCTURAL DRAWINGS MUST
BE BROUGHT TO THE IMMEDIATE ATTENTIONS OF THE STRUCTURAL ENGINEER (IN WRITING).
2. THE INFORMATION SHOWN ON THE DRAWING IS BASED ON THE EXISTING STRUCTURAL DRAWINGS, SURVEYED DATA AND PHOTOGRAPHS OF THE EXISTING BUILDING PROVIDED BY ARCH.
3. SEE ARCHITECTURAL PLANS FOR ALL OPENING LOCATIONS, DIMENSIONS AND INTERIOR PARTITIONS.
4. SEE PLAN, SCHEDULES AND SHEET S100 FOR DESIGN LOADS.
5. DO NOT CUT, CORE OR DEMOLISH ANY EXISTING BEAMS. OPENINGS MUST SHIFT TO AVOID AS-BUILT
LOCATION OF BEAMS.
6. ALL EXISTING PARTITIONS ARE ASSUMED TO BE OF LIGHT GAUGE CONSTRUCTION UNLESS NOTED
OTHERWISE. GC TO NOTIFY EOR IF DEMO WORK AT INTERIOR PARTITIONS CONTAIN
STRUCTURAL/ROLLED STEEL OR ARE OF MASONRY/CIP CONSTRUCTION.
7. ALL NEW OPENINGS GREATER THAN 5" IN DIAMETER OR 5"x5" ARE REQUIRED TO BE REINFORCED.
8. INDICATES 8" CMU WALL. #6 VERT. BARS AT 48" OC
9. AT ENDS OF CMU WALLS AND AT OPENINGS, GROUT (2) CONSECUTIVE CELLS SOLID WITH (1) #6 VERT BAR IN
EACH CELL.
10. SEE S600 FOR THE LINTEL SCHEDULE FOR NEW CMU PARTITIONS.
11. BRACE TOP OF MASONRY WALL WITH L4X4X1/4. 12" LONG @ 4'-0" O.C. SPACING. ALTERNATE SIDES OF THE MASONRY WALL. ANCHOR HORIZONTAL LEG AT UNDERSIDE OF EXIST. CONC. SLAB W/ (2) HILTI KWIK BOLT
3 WEDGE ANCHOR. 3/8" DIA. 2 1/4" LONG.
MW2
3/4" = 1'-0"
DETAIL AT NEW BUILDING 7 CMU PARTITION
REGISTRATION
LICENSE #:
I HEREBY CERTIFY THAT THIS PLAN,
SPECIFICATION, OR REPORT WAS
PREPARED BY ME OR UNDER MY
DIRECT SUPERVISION AND THAT I AM
A DULY LICENSED PROFESSIONAL
ENGINEER UNDER THE LAWS OF THE
STATE OF MINNESOTA.
PRINT NAME:
SIGNATURE:
DATE:
Zachary D. Craig
57219
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
CONFERENCE
M & O
OFFICE
M&O
101A
CLOSET
STORAGE
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
CONFERENCE
M & O
OFFICE
M&O
101A
CLOSET
7-TN300
7-TN300
2D
2D
4DD
D 2D
4D 2V 4D
WAP
WAP
WAP
WAP
E
E E
E E E
E E E
E
E E
E
LIMITS OF DATA CABLING DEMOLITION
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
7-TD110
FIRST FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
7 & 13
N
0 8' 16'4'
1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOM - DEMOLITION
1" = 50'-0"
KEY PLAN
NN
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
2. FOR EXISTING CABLE COUNT:
DATA CAT5e: 64 BLDG 6 (ROOM 104B) DATA CAT5e: 4 BLDG 12 (NO TELECOM ROOM) DATA CAT5e: 10 BLDG 54 (NO TELECOM ROOM) DATA CAT5e: 10 BLDG 69 (NO TELECOM ROOM)
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
SCALE: 1/4" = 1'-0"
BUILDING 13
101 102
STORAGE
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
SCALE: 1/4" = 1'-0"
BUILDING 13
101 102
7-TN400
102A
TELECOM ROOM
PLACEHOLDER BUILDING 13
4D 2V 4D
2D D
WAP
WAP
WAP
WAP
2DD
2D
4D
E
E E
E E E
E E E
E
E E
E
4" 1
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
7-TN110
FIRST FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
7 & 13
N
0 8' 16'4'
1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOMMUNICATIONS
1" = 50'-0"
KEY PLAN
NN
SHEET NOTES:
1. PROVIDE JUNCTION BOX TO CONNECT FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO THE
NEW TELECOM ROOM.
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
SCALE: 1/4" = 1'-0"
BUILDING 13
101 102
STORAGE
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
SCALE: 1/4" = 1'-0"
BUILDING 13
101 102
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
7-TN210
FIRST FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
7 & 13
1" = 30'-0"
FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
N
0 30' 60'15' 1" = 50'-0"
KEY PLAN
NN
101A
CLOSET
101A
CLOSET
WAP
E1
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:3
P
M
7-TN300
ENLARGED PLANS -
TELECOMMUNICATIONS -
DEMO
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
7 & 13
1/4" = 1'-0"
ENLARGED PLAN - BUILDING 7 - TR 102A - TELECOM - DEMO
1/4" = 1'-0"
ENLARGED PLAN - BUILDING 13 - EXIST RM 101 - TELECOM - DEMO
0 4' 8'2'
N
N
0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
SHEET NOTES:
1. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.
EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING
COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 102A (BUILDING 7)
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 6
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
2. ROOM 101 (BUILDING 13)
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 12
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
AC
CR
C
7-TN400
1 - a b
1 - c d
W 12"x4"
12"x4"
12"x4"
102A
TELECOM ROOM
C2 126"
DATA RACK
CABLE TRAY
KEYPAD
WAP
E
12"x4"12"x4"
4"
AC
R
NOTES:
1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.
4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO
SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).
5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.
7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.
VERTICAL CABLE
MANAGEMENT (TYP)
RACK 1
1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT5E BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
CHANNEL RACK (TYP)
D
PROVIDE DATA CABLE TO RACK
MOUNTED UPS FOR CONNECTION
TO MONITORING SYSTEM
RACK 1
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:3
:4
P
M
7-TN400
ENLARGED PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
7 & 13
N
0 2' 4'1'
0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
1. ROOM 102A (BUILDING 7)
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 28 FROM BLDG 6, 6 FROM BLDG 7, 12 FROM BLDG 13, 11 FROM BLDG 54, 10 FROM BLDG 69, 4 FROM BLDG 112
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6A): 71
DATA (CAT6): 0
1/2" = 1'-0"
ENLARGED PLAN - BUILDING 7 - TR 102A - TELECOM - CABLE TRAY AND DATA
1/4" = 1'-0"
1 - a
1/4" = 1'-0"
1 - b
1/4" = 1'-0"
1 - c
1/4" = 1'-0"
1 - d
NOT TO SCALE
COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - BUILDING 7 - TR 102A
SHEET NOTES:
1. PROVIDE A NEW ACCESS CONTROL PANEL TO BE INSTALLED IN THE TELECOM ROOM. THE CARD READER AND KEYPAD FOR THIS ROOM TO BE WIRED TO THE NEW ACCESS CONTROL PANEL. EXISTING CARD READERS AND KEYPADS WILL BE MOVED TO THE NEW CONTROL PANEL UNDER A DIFFERENT PROJECT.
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
CONFERENCE
M & O
OFFICE
M&O
101A
CLOSET
07-E300
7-P3 7-L1-1 7-P2 7-P1
7-ES
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
SEE 54-GI000
SEE 54-GI000
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:1
:4
A
M
07-E100
FIRST FLOOR DEMOLITION
PLAN - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
IMEG IMEG
16305
1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN - ELECTRICAL
NO SCALE
KEY PLAN
N
N
100% CD 03/30 05-06-2022
SALT
101B
STAIR
101A
CORR
ROOM
BRINE
ROOM
SOFTENER
OFFICE
104A
CLOSET
ROOM
BOILER
STORAGE
REPAIR &
ROOM
DEISEL
ROOM
DEISEL
LOCKER
PLUMBING
105A
CORRIDOR
109A
STORAGE
TOOL 110A
BATH
STORAGE
MASON
109B
STORAGE
MASON
SHOP
PLUMBING
111A
OFFICE
STOR.
SAFETY
SCALE: 1/4" = 1'-0"
UPDATED 12/10/01
BUILDING 13
101 102
E
7-P3 7-L1-1 7-P2 7-P1
7-ES
FAP
07-E300
07-E300
CU-7-1
B7IT-1-11
WP
102A
TELECOM
ROOM
PLACEHOLDER
BUILDING 13
PROPOSED TR
SEE 6-GI000
SEE 112-GI000
SEE 54-GI000
SEE 54-GI000
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:1
:5
A
M
07-E200
FIRST FLOOR PLAN -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
IMEG IMEG
16305
1/8" = 1'-0"
FIRST FLOOR PLAN - ELECTRICAL
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
NO SCALE
KEY PLAN
N
N
ROOM
BRINE
ROOM
BRINE
SD
E
101A
CORR
ROOM
BRINE
A
B7IT-1
a
A
B7IT-1
a
A
B7IT-2
b
A
B7IT-2
b ab
102A
TELECOM
ROOM
B7IT-1
AC-7-1
B7IT-1-3,5,7
B7IT-2-1,3,5
B7IT-1-1
42"
B7IT-2-7
42"
B7IT-1-1
42"
B7IT-2-7
42"
B7IT-1-1
42"
B7IT-2
102A
TELECOM
ROOM
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:1
:5
A
M
07-E300
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
IMEG IMEG
16305
N O R
HT
1/4" = 1'-0"
FIRST FLOOR ENLARGED - TR 102A - LIGHTING
N O R
HT
1/4" = 1'-0"
FIRST FLOOR ENLARGED - TR 102A - POWER & SYSTEM
N O R
HT
1/4" = 1'-0"
FIRST FLOOR DEMOLITION ENLARGED - ELEC 102 - ELECTRICAL
KEYNOTES:
1. DISCONNECT AND REMOVE LIGHTS AND
RECEPTACLES IN AREA OF NEW IT ROOM.
MAINTAIN CIRCUIT CONTINUITY TO ADJOINING
SPACES.
2. INDOOR UNIT TO BE POWERED BY OUTDOOR
UNIT. COORDINATE EXACT LOCATION WITH
M.C.
3. CONNECT SMOKE DETECTOR TO NEAREST
EXISTING SLC.
4. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-20R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#12, 1#12 GND
TO PANEL FOR EACH RECEPTACLE.
5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-
PHASE, 4-WIRE RACK MOUNTED UPS FOR
EACH RACK TOWER.
6. PROVIDE APC#AP8861 RPDU RACK PDU 2G
WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,
ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R
OUTLETS. PROVIDE TWO PER RACK, MOUNTED
PER MANUFACTURER'S REQUIREMENTS.
7. RELOCATE EXISTING LIGHT FIXTURE TO THE
NORTH TO AVOID NEW WALL.
SHEET NOTES:
1. REFER TO TECHNOLOGY PLANS FOR IT ROOM
LAYOUT AND RACK LAYOUT/DETAILS.
2. REFER TO SHEET 0-GE400 DETAIL FOR LAYOUT
& ONE-LINE OF RACK.
BASEMENT
FIRST FLOOR
B7IT-1
100Y
7-P3
B7IT-2
100Y
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:1
:5
A
M
07-E500
ELECTRICAL ONE-LINE
DIAGRAMS & SCHEDULES
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
IMEG IMEG
16305
N O R
HT
12" = 1'-0"
PARTIAL POWER RISER
KEYNOTES:
1. PROVIDE NEW 100A/3P CIRCUIT BREAKER IN
EXISTING PANEL TO MATCH EXISTING TYPE
AND AIC RATING.
100% CD 03/30
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 21.9 A
TOTAL CONNECTED AMPS: 21.92 A
Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 7.898 kVA
Power 7 kVA 100.00% 7 kVA TOTAL CONNECTED LOAD: 7.90 kVA
Lighting 0.178 kVA 100.00% 0.178 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 28.00 24.98 15.39
Total Load: 3.21 kVA 2.84 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 16 --
13 CU-7-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --
-- 7 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
3 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: TELECOM ROOM 102A WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B7IT-1
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 15.4 A
TOTAL CONNECTED AMPS: 15.37 A
Receptacles 0.36 kVA 100.00% 0.36 kVA TOTAL ESTIMATED DEMAND LOAD: 5.538 kVA
Power 5 kVA 100.00% 5 kVA TOTAL CONNECTED LOAD: 5.54 kVA
Lighting 0.178 kVA 100.00% 0.178 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 17.12 15.60 13.89
Total Load: 2.03 kVA 1.84 kVA 1.67 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 0.36 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: TELECOM ROOM 102A WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B7IT-2
7-P3
7-P3
05-06-2022
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/2
/2
:5
:3
A
M
07-E600
ELECTRICAL SCHEDULES
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
09/17/21
IMEG IMEG
16305
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 21.9 A
TOTAL CONNECTED AMPS: 21.92 A
Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 7.898 kVA
Power 7 kVA 100.00% 7 kVA TOTAL CONNECTED LOAD: 7.90 kVA
Lighting 0.178 kVA 100.00% 0.178 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 28.00 24.98 15.39
Total Load: 3.21 kVA 2.84 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 16 --
13 CU-7-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --
-- 7 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
3 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: TELECOM ROOM 102A WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B7IT-1
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 15.4 A
TOTAL CONNECTED AMPS: 15.37 A
Receptacles 0.36 kVA 100.00% 0.36 kVA TOTAL ESTIMATED DEMAND LOAD: 5.538 kVA
Power 5 kVA 100.00% 5 kVA TOTAL CONNECTED LOAD: 5.54 kVA
Lighting 0.178 kVA 100.00% 0.178 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 17.12 15.60 13.89
Total Load: 2.03 kVA 1.84 kVA 1.67 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 0.36 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: TELECOM ROOM 102A WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B7IT-2
7-P3 7-P3
100% CD 03/30
53095
TELECOM ROOM
102A
CORR
101A
STAIR
101B
SOFTNER ROOM
OFFICE
1"COND-E
4"STM-E
2"STM-E
PROPOSED
TR
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTA ARCHITECT/ENGINEER OF STAM
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 1
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/1
/2
:1
:1
P
M
07-M101
FIRST FLOOR
DEMOLITION -
MECHANICAL
EHRM
INFRASTRUCTURE
UPGRADES
656‐21‐235
RDL JCL
16305
7 & 13
1/4" = 1'-0"
FIRST FLOOR DEMOLITION - TELECOM 102A
KEYNOTES 1/07-M101:
1. REMOVE AND DISPOSE OF CAST IRON STEAM RADIATOR AND
ASSOCIATED PIPING AS SHOWN.
2. EXISTING 1" CONDENSATE RETURN TO BE DEMO'D BACK TO
LOCATION SHOWN. PREPARE PIPING FOR RECONNECTION.
3. REMOVE EXISTING 4" STEAM PIPING AS SHOWN AND PREPARE
ENDS FOR RECONNECTION. REFER TO 1/07-M201 FOR
REINSTALLATION.
4. REMOVE EXISTING 2" STEAM PIPING AS SHOWN AND PREPARE
ENDS FOR RECONNECTION. REFER TO 1/07-M201 FOR
REINSTALLATION.
5. REMOVE EXISTING 1" CONDENSATE PIPING AS SHOWN AND
PREPARE ENDS FOR RECONNECTION. REFER TO 1/07-M201 FOR
REINSTALLATION.
6. SUSPENDED STEAM HEATING UNIT TO REMAIN.
7. 12" DOMESTIC WATER LINE TO REMAIN.
8. 1-1/2" STEAM LINE SERVING RADIATOR TO BE DEMO'D
BACK AND CAPPED.
9. EXISTING STEAM GENERATOR TO REMAIN.
#FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT
THEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER, AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE OF
WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.
E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILIY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN
THEIR BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.
4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION.
NO SCALE
KEY PLAN
N
N
0 4' 8'2'
100% CD 03/3
T
BRINE ROOM
TELECOM ROOM
102A
CORR
101A
STAIR
101B
SOFTNER ROOM
OFFICE
AC-7-1
RACK
PROVIDED
BY OTHERS
CU-7-1
1" PC
CP-7-1
PROPOSED
TR
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTA ARCHITECT/ENGINEER OF STAM
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 1
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/1
/2
:1
:1
P
M
07-M201
FIRST FLOOR REMODEL -
MECHANICAL
EHRM
INFRASTRUCTURE
UPGRADES
656‐21‐235
RDL JCL
16305
7 & 13
1/4" = 1'-0"
FIRST FLOOR - MECHANICAL - TELECOM 102A
KEYNOTES 1/07-M201:
1. REROUTE AND RECONNECT EXISTING 4" STEAM LINE.
FIELD VERIFY EXACT LOCATION.
2. RE-PIPE AND SLEEVE EXISTING 1" CONDENSATE LINE.
3. NEW WALL MOUNTED DUCTLESS COOLING UNIT AC-7-1.
4. RE-ROUTE AND RECONNECT AND RECONNECT EXISTING
1" CONDENSATE LINE.
5. RE-ROUTE AND RECONNECT EXISTING 2" STEAM LINE.
6. ROUTE NEW REFRIGERANT PIPING TO AC-7-1 UNIT IN
TELECOM 102A.
7. NEW AIR-COOLED CONDENSING UNIT. PROVIDE
CONCRETE PAD. REFER TO 1/0-GM400 FOR
REFRIGERANT PIPING DETAIL. REFER TO 3/0-GM401 FOR
UNIT MOUNTING DETAIL.
8. PROVIDE NEW THERMOSTAT
9. ROUTE 1" CONDENSATE LINE TO EXISTING SUMP. FIELD
VERIFY REQUIREMENTS.
10. EXISTING SUSPENDED STEAM HEATING UNIT TO REMAIN.
11. EXISTING DOMESTIC WATER LINE. VERIFY NEW WALL
PROXIMITY AND COORDINATE WITH
ARCHITECT/ENGINEER.
12. EXTEND EXISTING 4" STEAM LINE 10 FEET TO THE EAST.
13. PROVIDE PIPE DRIP PAN AND PIPE WRAP ON TWO 4"
PLUMBING PIPE RUN. SEE DETAIL 6/01-M400.
14. ROUTE NEW REFRIGERANT PIPING THROUGH EXISTING
OPENING IN WALL. SEAL WALL PENETRATION AS
SPECIFIED.
15. EXISTING STEAM GENERATOR TOREMAIN.
16. REFERE TO 4/0-GM401 FOR WALL PENETRATION SEALING
DETAIL.
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT
THEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER, AND CONDITION OF ALL EXISTING HVAC
EQUIPMENT WITHIN SCOE OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.
E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILIY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN
THEIR BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.
4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION.
N
0 4' 8'2'
NO SCALE
KEY PLAN
N
NO SCALE
TELECOM 102A PHOTOS
100% CD 03/3
| 7-GI000 - BUILDINGS 7 & 13 COVER SHEET & SHEET INDEX |
| 7-GI001 - FIRST FLOOR LIFE SAFETY PLAN |
| 7-GI111 - FIRST FLOOR - INFECTION CONTROL & PHASING PLAN |
| 7-HA-1A - REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY |
| 7-HA-2A - REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY |
| 13-HA-1A - REFERENCE - FIRST FLOOR - ASBESTOS RE-SURVEY |
| 7-AS110 - FIRST FLOOR PLANS |
| 7-S110 - FIRST FLOOR PLANS |
| 7-TD110 - FIRST FLOOR PLAN - TELECOM - DEMOLITION |
| 7-TN110 - FIRST FLOOR PLAN - TELECOMMUNICATIONS |
| 7-TN210 - FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE |
| 7-TN300 - ENLARGED PLANS - TELECOMMUNICATIONS - DEMO |
| 7-TN400 - ENLARGED PLANS - TELECOMMUNICATIONS |
| 07-E100 - FIRST FLOOR DEMOLITION PLAN - ELECTRICAL |
| 07-E200 - FIRST FLOOR PLAN - ELECTRICAL |
| 07-E300 - ELECTRICAL ENLARGED PLANS |
| 07-E500 - ELECTRICAL ONE-LINE DIAGRAMS |
| 07-E600 - ELECTRICAL SCHEDULES |
| 07-M101 - FIRST FLOOR DEMOLITION - MECHANICAL |
| 07-M201 - FIRST FLOOR REMODEL - MECHANICAL |
File details come from the government source that posted it. Updated .