Atch 15 - BLDG 9 addendum.pdf
PDF 8 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
- Solicitation number
- 36C77622B0035
About this file
This solicitation requests proposals for infrastructure upgrades at the St. Cloud Veterans Affairs Health Care System. Contractors shall provide electrical, telecommunications, data center, and HVAC upgrades and renovations. Specific requirements include upgrading electrical systems, installing bonding and UPS equipment, integrating with building management systems, expanding security access and fiber infrastructure, hazardous materials abatement, and renovating existing spaces as needed. Proposals are due under solicitation number 36C77622B0035 issued by the Department of Veterans Affairs Technology Acquisition Center Austin.
View the file
Other files for this federal contract opportunity
Show all 50
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND
CORRIDOR OUTLINE
VFY EXIST
BUILDING OUTLINE
VFY EXIST
TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST
44TH AVE.
TRAIL 1
TRAIL 2
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2)
15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
GRAVEL
GRAVEL
GRAVEL
EXISTING
ROAD
CHAIN LINK FENCE
CHAIN LINK FENCE
16' GATE
GRAVEL
ELECTRICAL
SUBSTATION
G E N E R A T O R
FUEL LINES
CONDU ITS TO TU NNEL
M V
D U
C T
B A
N K
1 1 2 W
PHARMACY ADDITION
11 2 E
G E N E R A T O R
B
CORRIDOR LINK
A
C T
TR
A
IL
ER
174 s .f.
256 s .f.
185 s .f.
149 s ..f.
155 s .f.
104 s .f.
70 s. .f .
72 s .f.
110 s .f.
276 s .f.
112 s .f.
99 s .f.
57 s .f.
146 s .f.
434 s .f.
R A
MP
U P
1:
M A X
R A
MP
U P
1:
M A X
RA
M P
UP
1:2 0 M
AX
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2) 15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
.3
TRANSFORMER
BUILD ING
#91
5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN
O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW
C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D
P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S
R EC O M M EN D ATIO N S
N EW G AS SU P P LY M AIN
IN TO B U ILD IN G
SP AR E
P H O N E LIN E
EXTEN D S TO
E XISTIN G
P H O N E IN
B O ILER R O O M
P ER P LAN .
SP AR E
P H O N E
LIN E TO
M ETER
TU N N EL
E XTEN D S
A D D ITIO N AL
2'- 0" U N D ER
B U ILD IN G
FUEL LINE
VENT LINE
1,000 GAL.
UNDERGROUND
DIESEL FUEL
TANK
1,000/5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
S 1
LIG H T
N EW G AS SU P P LY
(C O O R D IN ATE W ITH SU P P LIER )
12"D
10"D
"D
TP TP
EXIST. BUILDING
EXIST.
BUS STOP
CC
L O
O P
16"
20"
12"
3"
8"
DN
0.
0’
BIRDCAGE
B
IR
D C
A G
E
NSP ELECTRICAL
FOR HWY DEPT
T101
I.T.
CHILLER
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
VESTIBULE
DN
DN
DN
FD
DN
F B
F
B
F B
F
B
F B
F
B
SOUTH
VESTIBULE
PASS
THROUGH
LINK TO
BUILDI NG 51
6 3. 32 56
1 13 5. 35 78
PARKING
NO
PARKING
93 49
37 6
109 5
1A
S M
O K
E B
L D
G
SMOKE
BLDG
SMOKE
BLDG
S M
O K
E B
L D
G
SMOKE
BLDG
M.H.
STOR.
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
STOR.
BIO-
HAZ.
SAUK RIVER
GP
HOLDING POND
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
OWNER AND
CONSULTANTS:
CONTACT:
ADDRESS:
MIKE ENGMARK
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
NAME:
ADDRESS:
CONTACT:
ADVANCED STRUCTURAL TECHNOLOGIES
7301 OHMS LANE; SUITE 215
EDINA, MN 55439
ZACHARY CRAIG
PHONE:
NAME:
ADDRESS:
CONTACT:
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
PHONE: 402-991-5520
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
IAN WEBER
763-412-4000
ARCHITECT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
EDWARD MARKFORT
763-412-4000
952-854-9302
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
402-991-5520
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
COVER
DATE:
APPROVED: APPROVED: PROJECTS SECTION MANAGER
APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:
APPROVED: SAFETY MANAGER
APPROVED: CHIEF OF POLICE
APPROVED: PATIENT SAFETY
DATE:
DATE:
DATE: APPROVED: EMS MANAGER
APPROVED: M/O MANAGER
DATE:
DATE:
DATE:DATE:
APPROVED: MEDICAL CENTER DIRECTOR
APPROVED: PROJECT COR DATE:
APPROVED: INFECTION CONTROL NURSE DATE:
APPROVED: SERVICE LINE DIRECTOR
APPROVED: GEMS COORDINATOR DATE:
DATE:
APPROVED: NURSE EXECUTIVE
APPROVED: CHIEF OF STAFF DATE:
APPROVED: DIRECTOR FMS
APPROVED: ASSOCIATE DIRECTOR
DATE:
DATE:
DATE:
DATE:APPROVED: DATE:
APPROVED: DATE:
APPROVED: DATE:
Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System
N
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
VICINITY MAP:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHONE: 320-252-1670
CIVIL ENGINEER:
VA COR:
TELECOMMUNICATIONS ENGINEER:
CONTACT:
ADDRESS:
JONATHAN WEST
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
PHONE: 504-250-2699
PROGRAM MANAGER:
EMAIL: Jonathan.West@vciint.com
STRUCTURAL ENGINEER:
MECH/ELEC/PLUMB/FIRE ENGINEER:
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -9
-R E
M a rk fo rt
.r v t
/2
/2
:1
:3
P
M
9-GI000
BUILDING 9 COVER SHEET &
SHEET INDEX
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
BUILDING 9 - EHRM INFRASTRUCTURE UPGRADES
03/30/2022
0APPROX 150' 300'75'
SHEET INDEX - BUILDING 9
SHEET NO. SHEET TITLE
9-GI000 BUILDING 9 COVER SHEET & SHEET INDEX
9-GI110 FIRST FLOOR LIFE SAFETY PLAN
9-GI111 FIRST FLOOR INFECTION CONTROL & PHASING PLAN
9-HA-1A REFERENCE - BASEMENT FLOOR ASBESTOS RE-SURVEY
9-HA-2A REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY
9-HA-3A REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY
9-HA-4A REFERENCE - ATTIC FLOOR ASBESTOS RE-SURVEY
9-AS100 BASEMENT, FIRST, AND SECOND FLOOR PLANS
9-TD100 FLOOR PLANS - TELECOM - DEMOLITION
9-TN100 FLOOR PLANS - TELECOMMUNICATIONS
9-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
9-TN300 ENLARGED PLANS - TELECOMMUNICATIONS - DEMO
9-TN400 ENLARGED PLANS - TELECOMMUNICATIONS
09-E100 FIRST FLOOR DEMOLITION - ELECTRICAL
09-E200 BASEMENT - ELECTRICAL
09-E201 FIRST FLOOR - ELECTRICAL
09-E300 ELECTRICAL ENLARGED PLANS
09-E500 ELECTRICAL ONE-LINE DIAGRAMS
09-E600 ELECTRICAL SCHEDULES
09-M101 FIRST FLOOR DEMOLITION - MECHANICAL
09-M201 FIRST FLOOR REMODEL - MECHANICAL
SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
ROOM SCHEDULE
NO. NAME C
A
B
LI
N G
P A
T C
H P
A N
E L
F
IB
E R
P O
W E
R
B O
N D
IN
G
U P
S
D E
D
IC
A T
E D
C O
O
LI
N G
T E
M P
E R
A T
U R
E
H U
M
ID
IT
Y
R A
C K
S E
N S
O R
S P
A C
E
AREA
WIDTH
(FT)
LENGTH
(FT)
HT TO
CLG
STRUCT REMARKS
BASEMENT
016 EXIST RM 35 SF 5.7 6.1 8.17 DECOMMISSION EXIST IT/DATA ROOM. SEE TELECOM
DRAWINGS. RELOCATE FUNCTION TO ROOM 100
FIRST FLOOR
100 LOBBY 249 SF MODIFIED FOR TELECOM ROOM, SEE MECH DRAWINGS
FOR ADDITIONAL REMARKS
100B TELECOM ROOM X X X X X X X X X X X 120 SF 14.1 8.5 9.33 CONSTRUCT TO EHRM TELECOM ROOM STANDARDS.
SEE TELECOM DRAWINGS
OPENING SCHEDULE
VA Building Number
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
9 LOBBY TELECOM ROOM 100B 3'-0" 7'-0" WD-F NONE HMS-1 NONE HW-3.2B 45 Y Y Y
HAZARDOUS MATERIAL SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
QUESTIONABLE HAZARDOUS
ELEMENT POSSIBLE ABATEMENT ACTION
BASEMENT 016 EXIST RM NONE. SEE 9-HA-1A NONE. ACM TO REMAIN UNDISTURBED
FIRST FLOOR 100 LOBBY ASBESTOS CONTAINING MASTIC
UNDER FLOOR TILE SEE 9-HA-2A
TO LIMITS OF TELECOM ROOM AND PLAN, REMOVE HAZARDOUS MATERIAL UNDER FULL CONTAINMENT
FIRST FLOOR 100B TELECOM ROOM ACM. SEE 9-HA-2A REMOVE HAZARDOUS MATERIAL UNDER FULL CONTAINMENT
HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT DISTURB
QUESTIONABLE HAZARDOUS MATERIAL.
ICRA PHASE CONSTRUCTION ROOM SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
CAI BLDG NAME /
FUNCTION
CONSTRUCTION
PROJECT ACTIVITY
INFECTION CONTROL
RISK GROUP
CONTROL
PROCEDURE CLASS SECTION
CONSTRUCTION ZONE /
OCCUPIED CONSTR
DAY /
NIGHT
BASEMENT 016 EXIST RM DOMICILIARY / POLICE TYPE B GROUP 1 CLASS II EAST OCCUPIED CONSTRUCTION NIGHT
FIRST FLOOR 100 LOBBY DOMICILIARY / POLICE TYPE B GROUP 2 CLASS II EAST ZONE9 NIGHT
FIRST FLOOR 100B TELECOM ROOM DOMICILIARY / POLICE TYPE C GROUP 2 CLASS III EAST ZONE9 NIGHT
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
1 UPDATE TO BID DOCUMENTS 06/29/22
F13
F12
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAIRS
OFFICE
SHOWER
TOILET
OFFICE
OFFICE
STAIRS
OFFICE
OFFICE
OFFICE
OFFICE
PRINTER/COPIER
ROOM
STAFF
GROUP/
CONF. ROOM
HSKP
LOBBY
WAITING ROOM
PORCH
VESTIBULE
100A
CLOSET
104A
CLOSET
121A
CLOSET
105A
CLOSET
106A
CLOSET
109A
CLOSET
111A
CLOSET
112A
CLOSET
120A
CLOSET
119A
CLOSET
118A
CLOSET
117A
CLOSET
116A
CLOSET
115A
CLOSET
114A
CLOSET
113A
CLOSET
122A
CORRIDOR
C1C
ELEV.
SHAFT
E01
100B
TELECOM
ROOM
TRAVEL DISTANCE
26'-6"
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
EDEXIT EXIT
HORIZONTAL EXIT
EXIT DISCHARGE
EXIT ACCESS
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
SMOKE
COMPARTMENT
BOUNDARY
HEALTH CARE
SUITE
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
OCCUPANCY
SEPARATION
SHAFT
ADJACENT SYMBOLS SHOW PARTITION RATING AND
DAMPER REQUIREMENTS
HAZARDOUS USE
ADJACENT SYMBOLS SHOW PARTITION RATING.
OPENINGS REQUIRE CLOSER & LATCH
EXIT PASSAGEWAY
RATE AS STAIR
ALL OPENINGS TO BE RATED AS STAIR SHAFT
CORRIDOR
WALLS TO LIMIT THE TRANSFER OF SMOKE
ADJUNCT CORRIDOR or PSYCHIATRIC AREA or CONSTRUCTED WITH MIN. 4'-0" CLEAR
WITH (PER CHAPTER 19)
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -9
-R E
M a rk fo rt
.r v t
/2
/2
:0 :0
P
M
9-GI110
FIRST FLOOR LIFE SAFETY
PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
1/8" = 1'-0"
FIRST LEVEL LIFE SAFETY PLAN
N
0 8' 16'4'
100B
TELECOM
ROOM
ZONE 9
CONSTRUCTION / ICRA BARRIER
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -9
-R E
M a rk fo rt
.r v t
/2
/2
:0 :1
P
M
9-GI111
FIRST FLOOR INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BW
16305
03/30/2022
1/8" = 1'-0"
FIRST FLOOR - CONST BARRIER PLAN
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
BASEMENT 016 EXIST RM DOMICILIARY / POLICE TYPE B GROUP 1 CLASS II
FIRST FLOOR 100 LOBBY DOMICILIARY / POLICE TYPE B GROUP 2 CLASS II
FIRST FLOOR 100B TELECOM ROOM DOMICILIARY / POLICE TYPE C GROUP 2 CLASS III
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
N
0 8' 16'4'
SEQUENCE OF EVENTS - ZONE 9
• SELECTIVE UPGRADE TO EXISTING INFORMATION TECHNOLOGY TO ENABLE
BUILDING TOTAL UPGRADE PROCESS
• INITIAL ICRA AND ILSM
• CONSTRUCTION OF BARRIER IN ONE NIGHT SHIFT. BARRIER INCLUDES DOOR
AND PARTITION TO BECOME PERMANENT CONSTRUCTION OF ROOM
• HAZARDOUS MATERIAL ABATEMENT AS INDICATED
• CONSTRUCT ROOMS AS DIRECTED, SEE ASSOCIATED DRAWINGS FROM
STRUCTURAL, ELECTRICAL, MECHANICAL, TELECOM, AND FINISHES
• INSTALL TEMPORARY PROTECTION AND CONDUCT SELECTIVE DEMOLITION TO
ENABLE UPGRADES
• INSTALL COMMON CABLE INFRASTRUCTURE
• CONSTRUCT COMMUNICATION BACKBONE
• INSTALL CAT 6A
• DECOMMISSION EXISTING NON-EHRM INFORMATION TECHNOLOGY ROOMS
SUGGESTED SEQUENCE. FINAL INSTALLATION SEQUENCE TO BE MADE AT A LATER DATE.
-ASBESTOS-CONTAINING FIRE DOOR
-ASBESTOS-CONTAINING MUDDED PIPE FITTINGS
-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE
-ASBESTOS-CONTAINING WINDOW CAULK
-ASBESTOS-CONTAINING BASEBOARD ADHESIVE
-ASBESTOS-CONTAINING MASTIC UNDER DOUBLE LAYER FLOOR TILE
-ASBESTOS-CONTAINING MASTIC UNDER FLOOR TILE AND CARPET
-ASBESTOS-CONTAINING MASTIC UNDER DOUBLE LAYER FLOOR TILE UNDER CARPET
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
BUILDING #9 - BASEMENT FLOOR PLAN
-ASBESTOS-CONTAINING MUDDED PIPE FITTINGS
-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE
-ASBESTOS-CONTAINING WINDOW CAULK
-ASBESTOS-CONTAINING BASEBOARD ADHESIVE
-ASBESTOS-CONTAINING MASTIC UNDER CARPET
-ASBESTOS-CONTAINING DOWNSPOUT RAIN LEADER TAR
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
BUILDING #9 - FIRST FLOOR PLAN
-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE
-ASBESTOS-CONTAINING WINDOW CAULK
-ASBESTOS-CONTAINING BASEBOARD ADHESIVE
-ASBESTOS-CONTAINING MASTIC UNDER CARPET AND FLOOR TILE
CASTLE HILL ASSOCIATES, LLC.
N
S
W E
BUILDING #9 - SECOND FLOOR PLAN
CASTLE HILL ASSOCIATES, LLC.
S
W E
NO ACM
BUILDING #9 - ATTIC FLOOR PLAN
XFMR
5'-8"
6' -1
/4
EXIST RM
100B
TELECOM
ROOM
8' -6
14'-1 1/4"
9-AS100
0B
100B
TELECOM
ROOM
0B
100A
ENTRY
LOBBY
IN-03.01
B3b
E X
IS
T
B3b
B3b
EXIST
3' -2
1/
2' -6
2'
-9
9/
100B
TELECOM
ROOM
TELECOM
ROOM
AFF8'-0"
LOBBY
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -9
-R E
M a rk fo rt
.r v t
/2
/2
:0 :0
P
M
9-AS100
BASEMENT, FIRST, AND
SECOND FLOOR PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
N
0 8' 16'4' 1/8" = 1'-0"1
BASEMENT FLOOR - OVERALL PLAN
1/8" = 1'-0"2
FIRST FLOOR - OVERALL PLAN
1/8" = 1'-0"3
SECOND FLOOR - OVERALL PLAN
N
0 8' 16'4'
N
0 8' 16'4'
1/4" = 1'-0"
ENLARGED FLOOR PLAN - RM 100B
N
0 4' 8'2'
1/4" = 1'-0"
DEMOLITION PLAN - RM 100B
N
0 4' 8'2'
1/4" = 1'-0"6
REFLECTED CEILING PLAN - RM 100B
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
DE2 REMOVE AND SALVAGE DOOR AND PREPARE OPENING TO
ACCOMMODATE PLAN. SEE FLOOR PLAN AND DOOR SCHEDULE
DE3 REMOVE WALL PARTITION IN ITS ENTIRETY.
DE4 CAREFULLY REMOVE AND SALVAGE EXISTING ACT CEILING SYASTEM AS
REQUIRED FOR NEW CONSTRUCTION.
DE14 REFER TO ELECTRICAL FOR REMOVAL OF DEVICES.
DE19 REMOVE EXISTING VCT FLOORING TO THE EXTENTS SHOWN. PREPARE
FOR INSTALLATION OF NEW FLOORING.
DE28 REMOVE AND SALVAGE DOOR PANEL
DE31 PREPARE WINDOW FOR SECURITY INFILL. REMOVE WINDOW SILL
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL2 DOOR, SIZE AS SCHEDULED, FIRE RESISTANT AS SCHEDULED
FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE
TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST
THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS
WITH FIRE CAULK.
FL5 FINISH NEW PARTITION WITH P-2 & RB-1
FL15 PROVIDE BLACK OUT FILM AT EXISTING WINDOW. NOTED WINDOW SIZE IS
APPROXIMATE. PROVIDE METAL SECURITY SCREEN AT EXTERIOR
WINDOW. INFILL INTERIOR OF WINDOW WITH METAL STUD PARTITION.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
RC4 PATCH AND ALIGN ACT WITH EXISTING
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
RC1
DE1
DE2
FL2
FL5
FL5
DE1
DE1
DE3
DE3
DE4
FL3
FL1
RC4
FL15
FL20
FL3
DE28
DE14
DE19
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION AND
CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE) WITH
WALL MOUNT BRACKET AND CODE REQUIRED SIGNAGE SHALL BE
PROVIDED WITHIN TELECOM ROOMS.
N
0 4' 8'2'
RC2
DE31
UNEXCAVATED
15A
SPACE
CRAWL
MECHANICAL
ROOM
SERVICE
13C
DISPATCH
POLICE
STAIR
STOR
POLICE
CHIEF OF
OFFICE
POLICE
STORAGE
STORAGE
STAIR
BREAKROOM
LOCKEROOM
FEMALE
MECH
LOCKEROOM
MALE
BATH
PATROL RM
POLICE
C0C
CORR
13A
OFFICE
POLICE
13B
OFFICE
POLICE
E01
ELEV
13D
ARMORY
DATA
1515A
13C
13B
13A
C0C
9 10
E01
13D
UNEXCAVATED
15A
SPACE
CRAWL
MECHANICAL
ROOM
SERVICE
13C
DISPATCH
POLICE
STAIR
STOR
POLICE
CHIEF OF
OFFICE
POLICE
STORAGE
STORAGE
STAIR
BREAKROOM
LOCKEROOM
FEMALE
MECH
LOCKEROOM
MALE
BATH
PATROL RM
POLICE
C0C
CORR
13A
OFFICE
POLICE
13B
OFFICE
POLICE
E01
ELEV
13D
ARMORY
DATA
1515A
13C
13B
13A
C0C
9 10
E01
13D
C
C
PORCH
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
OFFICE
OFFICE
OFFICE
C1C
CORR
SHOWER
OFFICE
OFFICE
BATH
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
PRINTER/COPIER
STAFF
CONF. RM
GROUP/
LOBBY
100A
ENTRY
STAIR
HAC
ROOM
WAITING
E01
ELEV
100A
C1C
112 113
E01
PORCH
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
OFFICE
OFFICE
OFFICE
C1C
CORR
SHOWER
OFFICE
OFFICE
BATH
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
PRINTER/COPIER
STAFF
CONF. RM
GROUP/
LOBBY
100A
ENTRY
STAIR
HAC
ROOM
WAITING
E01
ELEV
100A
C1C
112 113
E01
C
C
C
F11
F10
CONF. ROOM
STOR
STAIR
OFFICE
OFFICE
OFFICE
BATH
SHOWER
OFFICE
STAIR
C2C
CORR
OFFICE
OFFICE
E01
ELEV
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
221B
BATH
HAC
OFFICE
E01
212211
210 213
214209
208 215
206 217
21B
223200
C2C
2229-TN300
LIMITS OF DATA CABLING DEMOLITION
5D
5D
4D
4D
2D/1 4D
2D/1 4D/2
2D/1
D
2D1D
WAP
WAP
WAP
WAP
WAP
WAP
WAP
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
2D/1
4D
EE
E
E
8"x4"
8" x4
8" x4
8" x4
9-TN300
LIMITS OF DATA CABLING DEMOLITION
WAP
WAP
WAP
WAP
WAP
WAP
WAP
2V
2D
6D
4D
3D/1
2D/12D/1
2D/1
2D/1
2D/1
2D/1
2D/1
2D/1
2D/1
2D/12D/1
2D/1
2D/12D/1
2D/1 2D/1
E E
E
E
EE
EE
E
E E
E E
E
E E
E
EE
E
E
E
E
E E
E
E
E
E
E
E
E
E
8" x4
8"x4"
8" x4
8" x4
E
LIMITS OF DATA CABLING DEMOLITION
3D
4D
3D
3D
3D
3D 3D
3D
3D
3D
3D
3D
D
3D 4D
3D
3D
3D
3D
3D
3D
WAP
WAP
WAP
WAP
WAP
WAP
WAP
E
E
E
E
E
E
EE
E E
EE
E
E
E
E
E E
EE
E E
E
E
E
E
E
E
E
E
E
8" x4
8" x4
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:0
P
M
9-TD100
FLOOR PLANS - TELECOM -
DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
SHEET NOTES:
1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.
REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING
ROUTES.
N
0 8' 16'4'
N
0 8' 16'4'
N
0 8' 16'4' 1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOM - DEMOLITION
1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOM - DEMOLITION
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
15A
SPACE
CRAWL
MECHANICAL
ROOM
SERVICE
13C
DISPATCH
POLICE
STAIR
STOR
POLICE
CHIEF OF
OFFICE
POLICE
STORAGE
STORAGE
STAIR
BREAKROOM
LOCKEROOM
FEMALE
MECH
LOCKEROOM
MALE
BATH
PATROL RM
POLICE
C0C
CORR
13A
OFFICE
POLICE
13B
OFFICE
POLICE
E01
ELEV
13D
ARMORY
DATA
1515A
13C
13B
13A
C0C
9 10
E01
13D
BASEMENT
XFMR
UNEXCAVATED
15A
SPACE
CRAWL
MECHANICAL
ROOM
SERVICE
13C
DISPATCH
POLICE
STAIR
STOR
POLICE
CHIEF OF
OFFICE
POLICE
STORAGE
STORAGE
STAIR
BREAKROOM
LOCKEROOM
FEMALE
MECH
LOCKEROOM
MALE
BATH
PATROL RM
POLICE
C0C
CORR
13A
OFFICE
POLICE
13B
OFFICE
POLICE
E01
ELEV
13D
ARMORY
DATA
1515A
13C
13B
13A
C0C
9 10
E01
13D
BASEMENT
C
C
F13
F12
PORCH
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
OFFICE
OFFICE
OFFICE
C1C
CORR
SHOWER
OFFICE
OFFICE
BATH
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
PRINTER/COPIER
STAFF
CONF. RM
GROUP/
LOBBY
100A
ENTRY
STAIR
HAC
ROOM
WAITING
E01
ELEV
100A
C1C
112 113
E01
1ST FLOOR
1ST FLOOR
F13
F12
PORCH
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
OFFICE
OFFICE
OFFICE
C1C
CORR
SHOWER
OFFICE
OFFICE
BATH
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
PRINTER/COPIER
STAFF
CONF. RM
GROUP/
LOBBY
100A
ENTRY
STAIR
HAC
ROOM
WAITING
E01
ELEV
100A
C1C
112 113
E01
1ST FLOOR
1ST FLOOR
C
C
C
F11
F10
CONF. ROOM
STOR
STAIR
OFFICE
OFFICE
OFFICE
BATH
SHOWER
OFFICE
STAIR
C2C
CORR
OFFICE
OFFICE
E01
ELEV
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
221B
BATH
HAC
OFFICE
E01
212211
210 213
214209
208 215
206 217
21B
223200
C2C
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 100B
HORIZONTAL AND
VERTICAL ROUTE
TO ROOM 100B
5D
4D
4D
D
WAP
WAP
WAP
WAP
WAP
WAP
WAP
1D 2D
2D/1
2D/1
2D/1
4D/2
4D
5D
8" x4
8" x4
8" x4
8"x4"
2"
4"4"4"
4"
E
E
E
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
2D/1
4D
E
E
EE
E
E
4"
2"
UP
2"
9-TN400
100B
TELECOM ROOM
LIMITS OF DATA CABLING
REPLACEMENT FROM ROOM 100B
2D/1
2D/1
2D/1
2D/1
2D/1
2D/12D/1
2D/1
2D/1
2D/1
2D/1
2D/1
2D/1
2D/1
2D/1
3D/1
4D
6D
2D
WAP
WAP
WAP
WAP
WAP
WAP
2V
WAP
2D/1
4"4"4"
8" x4
8"x4"
8" x4
8" x4
E E
E
E
EE
EE
E
E E
E E
E
E E
E
EE
E
E
E
E
E E
E
E
E
E
E
E
E E
E
F212" LADDER
LIMITS OF DATA CABLING
REPLACEMENT FROM ROOM 100B
HORIZONTAL AND
VERTICAL ROUTE
TO ROOM 100B
WAP
WAP
WAP
WAP
WAP
WAP
WAP
3D 3D
3D3D
3D
3D
3D
4D
D
3D
3D3D
3D
3D
3D
3D
3D
3D
3D
4D
3D
8" x4
8" x4
E
E
E
E
E
E
EE
E E
EE
E
E
E
E
E E
EE
E E
E
E
E
E
E
E
E
E
E
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:0
P
M
9-TN100
FLOOR PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
SHEET NOTES:
1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE
TRAY.
2. PROVIDE JUNCTION BOX TO CONNECT FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO THE
NEW TELECOM ROOM.
N
0 8' 16'4'
N
0 8' 16'4'
N
0 8' 16'4' 1/8" = 1'-0"
BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOMMUNICATIONS
1/8" = 1'-0"
SECOND FLOOR PLAN - TELECOMMUNICATIONS
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
PORCH
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
OFFICE
OFFICE
OFFICE
C1C
CORR
SHOWER
OFFICE
OFFICE
BATH
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
PRINTER/COPIER
STAFF
CONF. RM
GROUP/
LOBBY
100A
ENTRY
STAIR
HAC
ROOM
WAITING
E01
ELEV
100A
C1C
112 113
E01
1ST FLOOR
1ST FLOOR
F13
F12
PORCH
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
OFFICE
OFFICE
OFFICE
C1C
CORR
SHOWER
OFFICE
OFFICE
BATH
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ROOM
PRINTER/COPIER
STAFF
CONF. RM
GROUP/
LOBBY
100A
ENTRY
STAIR
HAC
ROOM
WAITING
E01
ELEV
100A
C1C
112 113
E01
1ST FLOOR
1ST FLOOR
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:0
P
M
9-TN210
FIRST FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 30' 60'15' 1" = 30'-0"
FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
DATA
DATA
C
100A
ENTRY
100A 100A
ENTRY
100A
R
D E
DATA RACK
1 2
6D E
8" x4
E
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:0
P
M
9-TN300
ENLARGED PLANS -
TELECOMMUNICATIONS -
DEMO
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
1/4" = 1'-0"
ENLARGED PLAN - EXIST RM 16 - TELECOM - DEMO
1/4" = 1'-0"
ENLARGED PLAN - TR 100B -TELECOM - DEMO
0 4' 8'2'
N N
0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
SHEET NOTES:
1. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.
EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING
COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
2. EXISTING CABLE TRAY, SECURITY CAMERAS, GROUND BUS BARS, AND RACKS FROM DECOMMISSIONED
ROOMS ARE TO BE REUSED, WHEN POSSBILE, IN NEW CONSTRUCTION TRS.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 16
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 101
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
100A
ENTRY
100A 100A
ENTRY
100A
AC
CR
C
9-TN400
1 - a b
1 - c d
C2 126"
W
12"x4"
12"x4"
12"x4"
100B
TELECOM ROOM
F2
12" LADDER
DATA RACK
CABLE TRAY
6D E
12"x4"12"x4"
KEYPAD
8"x4"
AC
R
NOTES:
1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.
4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO
SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).
5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.
7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.
VERTICAL CABLE
MANAGEMENT (TYP)
RACK 1
1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT5E BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
CHANNEL RACK (TYP)
D
PROVIDE DATA CABLE TO RACK
MOUNTED UPS FOR CONNECTION
TO MONITORING SYSTEM
RACK 1
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCH
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/1
/2
:4
:0
P
M
9-TN400
ENLARGED PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 2' 4'1'
0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
1. ROOM 100B
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 101 FROM ROOM 16
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6A): 101
DATA (CAT6): 0
1/2" = 1'-0"
ENLARGED PLAN - TR 100B - TELECOM - CABLE TRAY AND DATA
1/4" = 1'-0"
1 - a
1/4" = 1'-0"
1 - b
1/4" = 1'-0"
1 - c
1/4" = 1'-0"
1 - d
NOT TO SCALE
COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - TR 100B
SHEET NOTES:
1. PROVIDE A NEW ACCESS CONTROL PANEL TO BE INSTALLED IN THE TELECOM ROOM. THE CARD READER AND KEYPAD FOR THIS ROOM TO BE WIRED TO THE NEW ACCESS CONTROL PANEL. EXISTING CARD READERS AND KEYPADS WILL BE MOVED TO THE NEW CONTROL PANEL UNDER A DIFFERENT PROJECT.
SD SD
E
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAIRS
OFFICE
SHOWER
TOILET
OFFICE
OFFICE
STAIRS
OFFICE
OFFICE
OFFICE
OFFICE
PRINTER/COPIER
ROOM
STAFF
GROUP/
CONF. ROOM
HSKP
LOBBY
WAITING ROOM
PORCH
VESTIBULE
100A
CLOSET
104A
CLOSET
121A
CLOSET
105A
CLOSET
106A
CLOSET
109A
CLOSET
111A
CLOSET
112A
CLOSET
120A
CLOSET
119A
CLOSET
118A
CLOSET
117A
CLOSET
116A
CLOSET
115A
CLOSET
114A
CLOSET
113A
CLOSET
122A
CORRIDOR
C1C
ELEV.
SHAFT
E01
09-E300
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:4
A
M
09-E100
FIRST FLOOR DEMOLITION -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - ELECTRICAL
0 8' 16'4'
N
100% CD 03/30
hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:
ate: 03/30/2022 cense Number: MN# 05-06-2022
CLAWL SPACE
15A
POLICE
PATROL RM
BATHROOM
POLICE
STORAGE
ELEV.
MECH. ROOM
FEMALE
LOCKEROOM
BREAKROOM
STORAGE
STORAGE
OFFICE
CHIEF OF
POLICE
STAIRS
SERVICE ROOM
MECHANICAL
STORAGE
CLOSET
8A
CLOSET
9A
CLOSET
11A
POLICE
OFFICE
13A
POLICE
OFFICE
13B
POLICE
DISPATCH
13C
STAIR
CORRIDOR
C0C
ELEV.
SHAFT
E01
ARMORY
13D
BASEMENT
09-E300
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:4
A
M
09-E200
BASEMENT - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
BASEMENT - ELECTRICAL
0 8' 16'4'
N
100% CD 03/30
hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:
ate: 03/30/2022
E
SD SD
E
F13
F12
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAIRS
OFFICE
SHOWER
TOILET
OFFICE
OFFICE
STAIRS
OFFICE
OFFICE
OFFICE
OFFICE
PRINTER/COPIER
ROOM
STAFF
GROUP/
CONF. ROOM
HSKP
LOBBY
WAITING ROOM
PORCH
VESTIBULE
100A
CLOSET
104A
CLOSET
121A
CLOSET
105A
CLOSET
106A
CLOSET
109A
CLOSET
111A
CLOSET
112A
CLOSET
120A
CLOSET
119A
CLOSET
118A
CLOSET
117A
CLOSET
116A
CLOSET
115A
CLOSET
114A
CLOSET
113A
CLOSET
122A
CORRIDOR
C1C
ELEV.
SHAFT
E01
09-E300
09-E300
B9IT-1-CR-11
WP
CU-9-1
B9IT-1-CR-13,15
100B
TELECOM
ROOM
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:4
A
M
09-E201
FIRST FLOOR - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
FIRST FLOOR - ELECTRICAL
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
0 8' 16'4'
N
100% CD 03/30
hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:
ate: 03/30/2022
MECHANICAL
CONF. ROOM
LOBBY
VESTIBULE
100A
SD
SD
E
SD SD
E
CONF. ROOM
LOBBY
VESTIBULE
100A
SD
SD SD
E
ROOM
GROUP/
CONF. ROOM
LOBBY
VESTIBULE
100A
FAP
9-MDP
9ES
ATS-EC
9ECB-1 9MDP
A
B9IT-1
a
A
B9IT-1
a
A
B9IT-1-CR
b
A
B9IT-1-CR
b ab
100B
TELECOM
ROOM
B9IT-1-CR
AC-9-1
B9IT-1-1,3,5
B9IT-1-CR-3,5,7
B9IT-1-CR-1
42"
B9IT-1-7
42"
B9IT-1-CR-1
42"
B9IT-1-7
42"
B9IT-1-7
42"
34 5
B9IT-1
100B
TELECOM
ROOM
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:5
A
M
09-E300
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/4" = 1'-0"
BASEMENT ENLARGED - MECH 15 - ELECTRICAL
1 1/4" = 1'-0"
FIRST FLOOR ENLARGED - TR 100B - LIGHTING
2 1/4" = 1'-0"
FIRST FLOOR ENLARGED - TR 100B - POWER & SYSTEM
1/4" = 1'-0"
FIRST FLOOR DEMOLITION ENLARGED - TR 100B - ELECTRICAL
SHEET NOTES:
1. REFER TO TECHNOLOGY PLANS FOR IT ROOM
LAYOUT AND RACK LAYOUT/DETAILS.
2. REFER TO SHEET 0-GE400 DETAIL LAYOUT &
ONE-LINE OF RACK.
KEYNOTES:
1. DISCONNECT AND REMOVE LIGHTS AND
RECEPTACLES IN AREA OF NEW IT ROOM.
MAINTAIN CIRCUIT CONTINUITY TO ADJOINING
SPACES.
2. INDOOR UNIT TO BE POWERED BY OUTDOOR
UNIT. COORDINATE EXACT LOCATION WITH
M.C.
3. CONNECT SMOKE DETECTOR TO NEAREST
EXISTING SLC.
4. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-20R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#12, 1#12 GND
TO PANEL FOR EACH RECEPTACLE.
5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-
PHASE, 4-WIRE RACK MOUNTED UPS FOR
EACH RACK TOWER.
6. PROVIDE APC#AP8861 RPDU RACK PDU 2G
WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,
ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R
OUTLETS. PROVIDE TWO PER RACK, MOUNTED
PER MANUFACTURER'S REQUIREMENTS.
N
N N N
0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
0 4' 8'2'
SWBD-9-MSB
100% CD 03/30
hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:
ate: 03/30/2022
B-9IT-1-CR
100Y
BASEMENT
FIRST FLOOR
B-9IT-1
100Y
SWB-9-MSB
9-ECB-1
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/6
/2
:4
:5
A
M
09-E500
ELECTRICAL ONE-LINE
DIAGRAMS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
12" = 1'-0"
PARTIAL POWER RISER
KEYNOTES:
1. PROVIDE NEW 100A/3P CIRCUIT BREAKER IN
EXISTING PANEL TO MATCH EXISTING TYPE
AND AIC RATING.
2. PROVIDE NEW 100A/3P SWITCH FUSED AT
100AMPS.
100% CD 03/30
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 15.5 A
TOTAL CONNECTED AMPS: 15.50 A
Receptacles 0.54 kVA 100.00% 0.54 kVA TOTAL ESTIMATED DEMAND LOAD: 5.584 kVA
Power 5 kVA 100.00% 5 kVA TOTAL CONNECTED LOAD: 5.58 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 18.45 14.32 13.89
Total Load: 2.21 kVA 1.71 kVA 1.67 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.04 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: TELECOM ROOM 100B WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B9IT-1
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 21.1 A
TOTAL CONNECTED AMPS: 21.05 A
Receptacles 0.54 kVA 100.00% 0.54 kVA TOTAL ESTIMATED DEMAND LOAD: 7.584 kVA
Power 7 kVA 100.00% 7 kVA TOTAL CONNECTED LOAD: 7.58 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 26.33 23.70 15.39
Total Load: 3.03 kVA 2.71 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 16 --
13 CU-9-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.04 0 -- -- -- 1 20 A SPARE 10 --
-- 7 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
3 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 TELECOM ROOM REC. 20 A 1 0.36 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: TELECOM ROOM 100B WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B9IT-1-CR
9-ECB-1
SWBD-9-MSB
hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:
ate: 03/30/2022
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/2
/2
:3
:1
P
M
09-E600
ELECTRICAL SCHEDULES
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 21.1 A
TOTAL CONNECTED AMPS: 21.05 A
Receptacles 0.54 kVA 100.00% 0.54 kVA TOTAL ESTIMATED DEMAND LOAD: 7.584 kVA
Power 7 kVA 100.00% 7 kVA TOTAL CONNECTED LOAD: 7.58 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 26.33 23.70 15.39
Total Load: 3.03 kVA 2.71 kVA 1.85 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 16 --
13 CU-9-1 20 A 2 1 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC. 20 A 1 0.18 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.04 0 -- -- -- 1 20 A SPARE 10 --
-- 7 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
3 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 TELECOM ROOM REC. 20 A 1 0.36 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: TELECOM ROOM 100B WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B9IT-1-CR
9-ECB-1
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 15.5 A
TOTAL CONNECTED AMPS: 15.50 A
Receptacles 0.54 kVA 100.00% 0.54 kVA TOTAL ESTIMATED DEMAND LOAD: 5.584 kVA
Power 5 kVA 100.00% 5 kVA TOTAL CONNECTED LOAD: 5.58 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 18.45 14.32 13.89
Total Load: 2.21 kVA 1.71 kVA 1.67 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 0.04 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 0.54 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 1.67 0 -- -- -- 1 20 A SPARE 4 --
1 L21-20R RACK 20 A 3 1.67 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: TELECOM ROOM 100B WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B9IT-1
SWBD-9-MSB
100% CD 03/30
53095
STAIRS
OFFICE
PRINTER/COPIER
HSKP
LOBBY
VESTIBULE
100A
CLOSET
104A
CLOSET
121A
CLOSET
122A
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/5
/2
:5
:2
P M
09-M101
FIRST FLOOR DEMOLITION -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
RDL DJC
16305
1/4" = 1'-0"
FIRST FLOOR DEMOLITION - TELECOM 100B
KEYNOTES 1/09-M101:
1. REMOVE AND DISPOSE OF EXISTING UNIT CONVECTOR AND CONTROLS. CAP
PIPING AT FLOOR.
2. REMOVE AND DISPOSE OF EXISTING SA DIFFUSER AND BRANCH DUCT
SECTION. CAP WHERE SHOWN.
3. REMOVE AND DISPOSE OF EXISTING SPRINKLER AND 1-1/4" SPRINKLER PIPE.
PREPARE FOR RECONNECTION.
4. REMOVE EXISTING SPRINKLER LINE BACK INTO LOBBY AREA AND PREPARE
FOR RECONNECTION.
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT THEIR
BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER, AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE
OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.
E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN THEIR
BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.
4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION.
N
0 8' 16'4'
T
STAIRS
OFFICE
PRINTER/COPIER
HSKP
LOBBY
VESTIBULE
100A
CLOSET
104A
CLOSET
121A
CLOSET
122A
AC-9-1
CU-9-1
CP-9-1
100B
TELECOM
ROOM
RACK PROVIDED
BY OTHERS
8CUH-5
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/5
/2
:5
:3
P M
09-M201
FIRST FLOOR REMODEL -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
RDL DJC
16305
1/4" = 1'-0"
FIRST FLOOR - MECHANICAL - TELECOM 100B
KEYNOTES 1/09-M201:
1. PROVIDE NEW WALL-MOUNTED DUCTLESS COOLING UNIT AC-9-1.
2. RE-ROUTE EXISTING 1-1/4" SPRINKLER PIPE. FIELD VERIFY EXACT
REQUIRMENTS.
3. PROVIDE NEW DEDICATED FIRE SPRINKLER BRANCH LINE AND SPRINKLER
HEAD.
4. CAP DUCT IN THIS LOCATION.
5. ROUTE NEW REFRIGERANT PIPING TO NEW CU-9-1 UNIT. LOCATE CU--9-1 ON
GRADE. REFER TO REFRIGERANT PIPING DETAIL 1/0-GM400.
6. PROVIDE NEW AIR COOLED CONDENSING UNIT. PROVIDE CONCRETE PAD. PAD
MOUNTING DETAIL 3/0-GM401
7. PROVIDE NEW THERMOSTAT - WIRE COMMON TO NEW AC UNIT AND CUH.
8. PROVIDE NEW CABINET UNIT HEATER CUH-5. MODIFY EXISTING PIPING AND
MAKE CONNECTION.
9. ROUTE 1" PUMPED CONDENSATE PIPING TO MOP SINK IN HSKP 102. PAN
CONDENSATE PUMP AND PIPING ASEMBLY WITHIN TELECOM ROOM 100B. FIELD
VERIFY REQUIRMENTS.
10. REFERE TO 4/0-GM401 FOR WALL PENETRATION SEALING DETAIL.
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT THEIR
BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER, AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE
OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.
E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN THEIR
BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.
4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION.
0 4' 8'2'
| 9-GI000 - BUILDING 9 COVER SHEET & SHEET INDEX |
| 9-GI110 - FIRST FLOOR LIFE SAFETY PLAN |
| 9-GI111 - FIRST FLOOR INFECTION CONTROL & PHASING PLAN |
| 9-HA-1A - REFERENCE - BASEMENT FLOOR ASBESTOS RE-SURVEY |
| 9-HA-2A - REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY |
| 9-HA-3A - REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY |
| 9-HA-4A - REFERENCE - ATTIC FLOOR ASBESTOS RE-SURVEY |
| 9-AS100 - BASEMENT, FIRST, AND SECOND FLOOR PLANS |
| 9-TD100 - FLOOR PLANS - TELECOM - DEMOLITION |
| 9-TN100 - FLOOR PLANS - TELECOMMUNICATIONS |
| 9-TN210 - FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE |
| 9-TN300 - ENLARGED PLANS - TELECOMMUNICATIONS - DEMO |
| 9-TN400 - ENLARGED PLANS - TELECOMMUNICATIONS |