Atch 32 - BLDG 115 addendum.pdf
PDF 5 MB Posted
- Attached to
- Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
- Solicitation number
- 36C77622B0035
About this file
This federal solicitation seeks a contractor to provide infrastructure upgrades at the St. Cloud Veterans Affairs Health Care System campus. Required work includes electrical, data center, fiber backbone, and HVAC improvements as well as building reconfiguration and hazardous materials abatement. The contractor must furnish all labor, materials, tools, and equipment to complete the upgrades in accordance with specifications and contract drawings. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 50
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LEGEND
CORRIDOR OUTLINE
VFY EXIST
BUILDING OUTLINE
VFY EXIST
TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST
44TH AVE.
TRAIL 1
TRAIL 2
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2)
15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
GRAVEL
GRAVEL
GRAVEL
EXISTING
ROAD
CHAIN LINK FENCE
CHAIN LINK FENCE
16' GATE
GRAVEL
ELECTRICAL
SUBSTATION
G E N E R A T O R
FUEL LINES
CONDU ITS TO TU NNEL
M V
D U
C T
B A
N K
1 1 2 W
PHARMACY ADDITION
11 2 E
G E N E R A T O R
B
CORRIDOR LINK
A
C T
TR
A
IL
ER
174 s .f.
256 s .f.
185 s .f.
149 s ..f.
155 s .f.
104 s .f.
70 s. .f .
72 s .f.
110 s .f.
276 s .f.
112 s .f.
99 s .f.
57 s .f.
146 s .f.
434 s .f.
R A
MP
U P
1:
M A X
R A
MP
U P
1:
M A X
RA
M P
UP
1:2 0 M
AX
TRANSFER
SWITCH
CAPACITOR
BANK (3)
SWITCH
(2) 15KV
MAIN
SW
BATT
35 KV
TO
15 KV
TRANSFORMER
35KV
FUSED
SWITCH
METER 35KV
SWITCH
.3
TRANSFORMER
BUILD ING
#91
5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN
O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW
C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D
P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S
R EC O M M EN D ATIO N S
N EW G AS SU P P LY M AIN
IN TO B U ILD IN G
SP AR E
P H O N E LIN E
EXTEN D S TO
E XISTIN G
P H O N E IN
B O ILER R O O M
P ER P LAN .
SP AR E
P H O N E
LIN E TO
M ETER
TU N N EL
E XTEN D S
A D D ITIO N AL
2'- 0" U N D ER
B U ILD IN G
FUEL LINE
VENT LINE
1,000 GAL.
UNDERGROUND
DIESEL FUEL
TANK
1,000/5,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
1,000 GAL.
UNDERGROUND
DIESEL FUEL TANK
S 1
LIG H T
N EW G AS SU P P LY
(C O O R D IN ATE W ITH SU P P LIER )
12"D
10"D
"D
TP TP
EXIST. BUILDING
EXIST.
BUS STOP
CC
L O
O P
16"
20"
12"
3"
8"
DN
0.
0’
BIRDCAGE
B
IR
D C
A G
E
NSP ELECTRICAL
FOR HWY DEPT
T101
I.T.
CHILLER
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
C O
NC
. B
LO
CKS
PAT
I O
DN
DN
FD
DN
F B
F
B
F B
F
B
F B
F
B
SOUTH
VESTIBULE
PASS
THROUGH
LINK TO
BUILDI NG 51
6 3. 32 56
1 13 5. 35 78
PARKING
NO
PARKING
93 49
37 6
109 5
1A
S M
O K
E B
L D
G
SMOKE
BLDG
SMOKE
BLDG
S M
O K
E B
L D
G
SMOKE
BLDG
M.H.
STOR.
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
SMOKE
BLDG
STOR.
BIO-
HAZ.
SAUK RIVER
GP
HOLDING POND
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
OWNER AND
CONSULTANTS:
CONTACT:
ADDRESS:
MIKE ENGMARK
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
NAME:
ADDRESS:
CONTACT:
ADVANCED STRUCTURAL TECHNOLOGIES
7301 OHMS LANE; SUITE 215
EDINA, MN 55439
ZACHARY CRAIG
PHONE:
NAME:
ADDRESS:
CONTACT:
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
PHONE: 402-991-5520
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
NAME:
ADDRESS:
CONTACT:
PHONE:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
IAN WEBER
763-412-4000
ARCHITECT:
ANDERSON ENGINEERING OF MN, LLC
13605 1ST AVE NORTH, SUITE 100
PLYMOUTH, MN 55441
EDWARD MARKFORT
763-412-4000
952-854-9302
SPECIALIZED ENGINEERING SOLUTIONS
10360 ELLISON CIRCLE
OMAHA, NE 68134
KRIS BURNHAM
402-991-5520
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
COVER
DATE:
APPROVED: APPROVED: PROJECTS SECTION MANAGER
APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:
APPROVED: SAFETY MANAGER
APPROVED: CHIEF OF POLICE
APPROVED: PATIENT SAFETY
DATE:
DATE:
DATE: APPROVED: EMS MANAGER
APPROVED: M/O MANAGER
DATE:
DATE:
DATE:DATE:
APPROVED: MEDICAL CENTER DIRECTOR
APPROVED: PROJECT COR DATE:
APPROVED: INFECTION CONTROL NURSE DATE:
APPROVED: SERVICE LINE DIRECTOR
APPROVED: GEMS COORDINATOR DATE:
DATE:
APPROVED: NURSE EXECUTIVE
APPROVED: CHIEF OF STAFF DATE:
APPROVED: DIRECTOR FMS
APPROVED: ASSOCIATE DIRECTOR
DATE:
DATE:
DATE:
DATE:APPROVED: DATE:
APPROVED: DATE:
APPROVED: DATE:
Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System
N
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
VICINITY MAP:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PHONE: 320-252-1670
CIVIL ENGINEER:
VA COR:
TELECOMMUNICATIONS ENGINEER:
CONTACT:
ADDRESS:
JONATHAN WEST
ST CLOUD VA MEDICAL CENTER
4801 VETERANS DRIVE
ST. CLOUD, MN 56303
PHONE: 504-250-2699
PROGRAM MANAGER:
EMAIL: Jonathan.West@vciint.com
STRUCTURAL ENGINEER:
MECH/ELEC/PLUMB/FIRE ENGINEER:
C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -1
-R
E
M a rk fo rt
.r v t
/2
/2
:4
:2
P
M
115-GI000
BUILDING 115 COVER SHEET &
SHEET INDEX
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
BUILDING 115 - EHRM INFRASTRUCTURE UPGRADES
03/30/2022
0APPROX 150' 300'75'
SHEET INDEX - BUILDING 115
SHEET NO. SHEET TITLE
115-GI000 BUILDING 115 COVER SHEET & SHEET INDEX
115-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN
115-AS110 FIRST FLOOR PLANS
115-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION
115-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS
115-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
115-TN400 ENLARGED PLANS - TELECOMMUNICATIONS
115-E201 FIRST FLOOR - ELECTRICAL
115-E300 ELECTRICAL ENLARGED PLANS
115-M101 FIRST FLOOR DEMOLITION - MECHANICAL
115-M201 FIRST FLOOR - MECHANICAL
SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
ROOM SCHEDULE
NO. NAME C
A
B
LI
N G
P A
T C
H P
A N
E L
F
IB
E R
P O
W E
R
B O
N D
IN
G
U P
S
D E
D
IC
A T
E D
C O
O
LI
N G
T E
M P
E R
A T
U R
E
H U
M
ID
IT
Y
R A
C K
S E
N S
O R
S P
A C
E
AREA
WIDTH
(FT)
LENGTH
(FT)
HT TO
CLG
STRUCT REMARKS
FIRST FLOOR
107 TELECOM ROOM X X X X X 74 SF 8.1 9.0 13.25 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM ROOM
STANDARDS. SEE TELECOM DRAWINGS
OPENING SCHEDULE
VA Building Number
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
HAZARDOUS MATERIAL SCHEDULE
LEVEL ROOM NO. ROOM NAME
QUESTIONABLE HAZARDOUS
ELEMENT POSSIBLE ABATEMENT ACTION
FIRST FLOOR 107 TELECOM ROOM NONE NONE
HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT
DISTURB QUESTIONABLE HAZARDOUS MATERIAL.
ICRA PHASE CONSTRUCTION ROOM SCHEDULE
LEVEL
ROOM
NO. ROOM NAME
CAI BLDG NAME /
FUNCTION
CONSTRUCTION
PROJECT ACTIVITY
INFECTION CONTROL
RISK GROUP
CONTROL
PROCEDURE CLASS SECTION
CONSTRUCTION ZONE /
OCCUPIED CONSTR
DAY /
NIGHT
FIRST FLOOR 107 TELECOM ROOM MENTAL HEALTH BEDS TYPE C GROUP 2 CLASS III EAST OCCUPIED CONSTRUCTION DAY
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
1 UPDATE TO BID DOCUMENTS 06/29/22
DN
CORRIDOR
PAT TLT
141A
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
SEMI PRIVATE #2
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
TELECOM
ROOM
INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND
LIMITS OF CONSTRUCTION
1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER
LOCATION, AND DOOR, WHERE SHOWN
TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER
LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.
UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -1
-R
E
M a rk fo rt
.r v t
/2
/2
:1 :3
P
M
115-GI111
FIRST FLOOR - INFECTION
CONTROL & PHASING PLAN
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM BMW
16305
03/30/2022
1/8" = 1'-0"
FIRST FLOOR - CONST BARRIER PLAN
ROOM ICRA SCHEDULE
LEVEL
ROOM
NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS
FIRST FLOOR 107 TELECOM ROOM MENTAL HEALTH BEDS TYPE C GROUP 2 CLASS III
SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.
FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.
N
0 8' 16'4'
PAT TLT
141A
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
SEMI PRIVATE #2
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
TELECOM
ROOM
8' -1
/4
9'-0 1/2"
115-AS110
TELECOM
ROOM
3'-0" 3'-0 3/4"
TELECOM
ROOM
TELECOM
ROOM
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of
Minnesota.
Name:
Date: License Number: MN# 18157
Typed or Printed Name: Tom Olesak
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10 C
U s e rs
\P u b li c \D o c u m e n ts \R e v it
P ro je c ts
\1 -1
-R
E
M a rk fo rt
.r v t
/2
/2
:1 :4
P
M
115-AS110
FIRST FLOOR PLANS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
EM EM
16305
03/30/2022
N
0 8' 16'4' 1/8" = 1'-0"
FIRST FLOOR - OVERALL PLAN
1/4" = 1'-0"3
ENLARGED FLOOR PLAN
N
0 4' 8'2'
1/4" = 1'-0"
DEMOLITION PLAN
N
0 8' 16'4'
1/4" = 1'-0"4
REFLECTED CEILING PLAN
N
0 8' 16'4'
DE1
RC1
_DEMOLITION PLAN KEYED NOTES
DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM
REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”
TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH
HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT
FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT
OVER FIRE RATING STAMP.
FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_REFLECTED CEILING PLAN KEYED NOTES
RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET
ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE
VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET
ROW OR SECTION.
RC2 OPEN TO STRUCTURAL FLOOR ABOVE
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
DE1
FL1 FL20
RC2
_SHEET NOTES
1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL
INFORMATION, LIFE SAFETY, ICRA, AND PHASING
2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND
ENGINEERS.
3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND
PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
DEMOLITION AND CONSTRUCTION REQUIREMENTS.
5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS
DETERMINED BY THE VA) WITH WALL MOUNT BRACKET AND CODE
REQUIRED SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN
TELECOM ROOMS.
157159
167186
167 60
167 167
60 165
251 64
121 106
112121
88 88
125145
642 607
DESK
30X66
DESK
30X66
LAT. FILE
18X42
B O
O K
S
TABLE
36" DIA.
LAT. FILE
18X42
B O
O K
S
DESK
30X66
B O
O K
S
L A
T . F
IL
E
X
D E
S K
X
LAT. FILE
18X42
BOOKS
TABLE
36" DIA.
DESK
30X66
L A
T . F
IL
E
X
B O
O K
S
D E
S K
X
LAT. FILE
18X42
B O
O K
S
DN
CORRIDOR
PAT TLT
141A
LINK
CONCOURSE
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
TEL / DATA
157159
167186
167 60
167 167
60 165
251 64
121 106
112121
88 88
125145
642 607
DESK
30X66
DESK
30X66
LAT. FILE
18X42
B O
O K
S
TABLE
36" DIA.
LAT. FILE
18X42
B O
O K
S
DESK
30X66
B O
O K
S
L A
T . F
IL
E
X
D E
S K
X
LAT. FILE
18X42
BOOKS
TABLE
36" DIA.
DESK
30X66
L A
T . F
IL
E
X
B O
O K
S
D E
S K
X
LAT. FILE
18X42
B O
O K
S
DN
CORRIDOR
PAT TLT
141A
LINK
CONCOURSE
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
TEL / DATA
LAT. FILE
18X42
CORRIDOR
CORRIDOR
TEL / DATA
LAT. FILE
18X42
CORRIDOR
CORRIDOR
TEL / DATA
C
115-TD110
LIMITS OF DATA CABLING DEMOLITION
E
E
E
EE
E
12"x2"
12"x2"
"x
2"
12"x2"
12"x2"
"x
2"
"x 2"
E E
E
12"x2"
"x
2"
3" 3"
D
D
DATA RACKS
E
D
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/2
/2
:4
:3
A
M
115-TD110
FIRST FLOOR PLAN -
TELECOM - DEMOLITION
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 8' 16'4' 1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOM - DEMOLITION
1/4" = 1'-0"
ENLARGED PLAN -EXIST RM 107 - TELECOM - DEMO
N
0 4' 8'2'
SHEET NOTES:
1. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.
EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING
COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.
GENERAL NOTES:
A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE
RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT.
1. ROOM 107
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 94
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6): 94
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
PAT TLT
141A
LINK
CONCOURSE
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
DN
CORRIDOR
PAT TLT
141A
LINK
CONCOURSE
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
TELECOM ROOM
115-TN400
LIMITS OF DATA CABLING REPLACEMENT
FROM ROOM 107
C2 126"
3"3"
4"
4"
12"x2"
12"x2"
"x
2"
"x
2"
12"x2"
12"x2"
"x
2"
E
E
E
EE
E
4"
12"x2" E E
E
"x
2"
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/2
/2
:4
:3
A
M
115-TN110
FIRST FLOOR PLAN -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
SHEET NOTES:
1. PROVIDE JUNCTION BOX TO CONNECT EXISTING FIBER CONDUIT ENTRY TO EXTEND CONDUIT
PATHWAY TO THE NEW TELECOM ROOM.
N
0 8' 16'4' 1/8" = 1'-0"
FIRST FLOOR PLAN - TELECOMMUNICATIONS
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
PAT TLT
141A
LINK
CONCOURSE
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
DN
CORRIDOR
PAT TLT
141A
LINK
CONCOURSE
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/2
/2
:4
:3
A
M
115-TN210
FIRST FLOOR PLAN -
TELECOM - CABLE DISTANCE
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 30' 60'15' 1" = 30'-0"
FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
CORRIDOR
CORRIDOR
A C
C R
C
E
12"x2"
12"x2"
12"x2" 12"x2"
12"x2"
CABLE TRAY
115-TN400
1 - a b
1 - c d
C2 126"
KEYPAD
W
DATA
RACK
4"
3"
E 12"x2"
E
VERTICAL CABLE
MANAGEMENT (TYP)
RACK 1
1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL
1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)
1U 48 PORT CAT5E BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
6U 5KW RACK MOUNT UPS
6U SPACE FOR FUTURE USE. PROVIDE BLANK
PANELS FOR UNUSED SPACES.
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
NEMA L21-20R (TYP)
CHANNEL RACK (TYP)
D
PROVIDE DATA CABLE TO RACK
MOUNTED UPS FOR CONNECTION
TO MONITORING SYSTEM
RACK 1
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U 48 PORT CAT6A ANGLED DATA PATCH PANEL
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCHES
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCHES
VA OIT PROVIDED 1U 48 PORT SWITCHES
2U CABLE MANAGEMENT
1U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCHES
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCHES
2U CABLE MANAGEMENT
2U CABLE MANAGEMENT
VA OIT PROVIDED 1U 48 PORT SWITCHES
SPACE FOR FUTURE HORIZONTAL CABLE
DISTRIBUTION. PROVIDE BLANKING PANELS FOR
UNUSED SPACES.
NOTES:
1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.
4. CONTRACTOR TO PROVIDE PATCH PANELS AND HORIZONTAL CABLE MANAGEMENT TO SUPPORT THE DATA COUNT ON
THE WORK PLAN + 1 ADDITIONAL SPARE PATCH PANEL. (NOT TO EXCEED 288 PORTS PER RACK)
5. SPARE RACKS WITH NO HARDWARE CONFIGURED IN THEM MUST HAVE THE STANDARD UPS INSTALLED UNLESS THE
ROOM HAS A CENTRAL UPS SOURCE.
6. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
7. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER
ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.
8. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.
Nathan M. TimmNo DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.T
R
.r v t
/2
/2
:4
:3
A
M
115-TN400
ENLARGED PLANS -
TELECOMMUNICATIONS
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
03/30/2022
KSB SSK
16305
N
0 2' 4'1'
0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
GENERAL NOTES:
A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.
CABLING NOTE:
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
1. ROOM 107
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5e): 94
DATA (CAT5): 0
DATA (CAT3): 0
CABLE RELOCATION COUNT
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
DATA (CAT5e): 0
DATA (CAT5): 0
DATA (CAT3): 0
FINAL CABLE COUNT
DATA (CAT6A): 94
DATA (CAT6): 0
1/2" = 1'-0"
ENLARGED PLAN - TR 107 - TELECOM - CABLE TRAY AND DATA
1/4" = 1'-0"
1 - a
1/4" = 1'-0"
1 - b
1/4" = 1'-0"
1 - c
1/4" = 1'-0"
1 - d
NOT TO SCALE
COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - TR 107
E
CORRIDOR
PAT TLT
141A
LINK
CONCOURSE
CORRIDOR
CORRIDOR
CORRIDOR
PAT TLT
139A
PAT TLT
140A
PAT RM #1
PAT RM #2
SEMI PRIVATE #1
SEMI PRIVATE #2
OFFICE
WARD CLERK
110PAT TLT
120A
LAUNDRY / TUB
HEAD NURSE
ENVIRON
STORAGE /HSKP
PAT TLT
136A
PAT TLT
132A
CRAWL SPACE
ACCESS
127A
STORAGE
EM EXIT
PAT TLT
129A
PAT TLT
130APAT TLT
131A
SEMI PRIVATE #5
SEMI PRIVATE #6
SEMI PRIVATE #4
SEMI PRIVATE #3
DINING
DAY ROOM
133A
RESTRAINT
ROOM
120C
CORRIDOR
CORRIDOR
CORRIDOR
103-2
RECEIVING
CORRIDOR
RECEPTION
SECURITY DESK
104A
FAMILY WAITING
LOCKERS
104C
CORRIDOR
CORRIDOR
PUBLIC TLT
PUBLIC TLT
SOCIAL WORK
OFFICE (FUTURE
ELEVATOR)
SOCIAL WORK
(FUTURE
ELEVATOR)
EXAM RM
BARIATRIC PAT
RM #6
PAT TLT
121A
OFFICE
PAT RM #8
PAT TLT
124A
PAT TLT
126A
QUIET LOUNGE
PAT TLT
137A
PAT TLT
138A
PAT TLT
123A
ELEC
COPY
SPS
SOILED HOLD
SALLY PORT
SALLY PORT
CLEAN LINEN
INTAKE
ANTE
SECLUSION
120B
MEDS
NURSE WORK
122A
NURSE STATION
VESTIBULE
PAT RM #5
MECHANICAL
STAFF LOUNGE
104D
GROUP
THERAPY
PAT RM #7
STAFF TLT
104B
PAT RM #4
PAT RM #3
TELECOM
ROOM
115-E300
CU-115-1
115-L1-3-42
WP
115-EC1-1-40,42
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/2
/2
:4
:2
P
M
115-E201
FIRST FLOOR - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
1/8" = 1'-0"
FIRST FLOOR - ELECTRICAL
0 8' 16'4'
N
100% CD 03/30
53095
E
GB
CORRIDOR
CORRIDOR
103-2 ELEC
STAFF LOUNGE
104D
TELECOM
ROOM
115-EQ1-1 115-EQ1-2 115-EQ1-3 115-EC1-1 115-L1-3
115-L1-1
115-MSB-1
TF-115-EMC1-1TF-115-EQ1-1
TF-115-L1-1TF-115-L1-2115-ES1-ATS1
115-EC1-ATS1
115-EQ1-ATS1
FAP
AC-115-1
115-L1-3-37,39,41
115-EC1-1-37,39,41
2 3
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.E
R
.r v t
/2
/2
:4
:2
P
M
115-E300
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/4" = 1'-0"
FIRST FLOOR ENLARGED - ELEC 107 & 160 - ELECTRICAL
N
0 4' 8'2'
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 16.7 A
TOTAL CONNECTED AMPS: 16.65 A
TOTAL ESTIMATED DEMAND LOAD: 6 kVA
TOTAL CONNECTED LOAD: 6.00 kVA
Power 6 kVA 100.00% 6 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 16.67 16.67 16.67
Total Load: 2.00 kVA 2.00 kVA 2.00 kVA
-- 41 -- -- -- -- -- -- 2 0 -- -- -- -- -- -- 42 --
-- 39 -- -- -- -- -- -- 2 0 2 20 A CU-115-1 40
37 L21-30R 20 A 3 2 38
35 36
33 34
31 32
29 30
27 28
25 26
23 24
21 22
19 20
17 18
15 16
13 14
11 12
9 10
7 8
5 6
3 4
1 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
ISC UNKNOWN 0.00 kA
SCCR: 65 kA
LOCATION: WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL 115-EC1-1
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 17.2 A
TOTAL CONNECTED AMPS: 17.15 A
TOTAL ESTIMATED DEMAND LOAD: 6.18 kVA
Receptacles 0.18 kVA 100.00% 0.18 kVA TOTAL CONNECTED LOAD: 6.18 kVA
Power 6 kVA 100.00% 6 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 16.67 16.67 18.17
Total Load: 2.00 kVA 2.00 kVA 2.18 kVA
-- 41 -- -- -- -- -- -- 2 0.18 1 20 A GFI RECEPTACLE 42
-- 39 -- -- -- -- -- -- 2 40
37 L21-30R 20 A 3 2 38
35 36
33 34
31 32
29 30
27 28
25 26
23 24
21 22
19 20
17 18
15 16
13 14
11 12
9 10
7 8
5 6
3 4
1 2
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
ISC UNKNOWN 0.00 kA
SCCR: 65 kA
LOCATION: WIRE: 4
FED FROM: 0 A/0P @ GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL 115-L1-3
KEYNOTES:
1. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-20R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#10, 1#12 GND
TO PANEL FOR EACH RECEPTACLE.
2. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-
PHASE,4-WIRE RACK MOUNTED UPS FOR EACH
RACK TOWER.
3. PROVIDE APC#AP8861 RPDU RACK PDU 2G
WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,
ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R
OUTLETS. PROVIDE TWO PER RACK, MOUNTED
PER MANUFACTURER'S REQUIREMENTS.
4. INDOOR UNIT TO BE POWERED BY OUTDOOR
UNIT. COORDINATE EXACT LOCATION WITH
M.C.
100% CD 03/30
53095
T
DESK
30X66
LAT. FILE
18X42
B O
O K
S
CORRIDOR
CORRIDOR
103-2
TEL / DATA
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES AND COR PRIOR TO INSTALLATION TO
PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE,
AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE COR AND THE ARCHITECT/ENGINEER BEFORE
PROCEEDING WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER
ACCESS. FINAL LOCATIONS TO BE ACCURATELY DESCRIBED IN AS-BUILTS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST, TIME OR
EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
7. REFER TO CONTRACT DOCUMENTS, TO INCLUDE BUT NOT LIMITED TO, THE
ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIO/VISUAL, AND
OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES,
OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO THE SATISFACTION OF THE COR TO MATCH ORIGINAL
CONSTRUCTION, FIRE RATING, AND FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
COR FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE
PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE COR OF THE REQUIRED ACCESS
PANELS PRIOR TO BIDDING.
10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING,
AND DUCTS PENETRATE, BOTH NEW AND EXISTING. PENETRATIONS THROUGH EXTERIOR
WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH WATERPROOFING MATERIALS
RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL,
PARTITION, FLOOR, AND ROOF ASSEMBLIES, BOTH NEW AND EXISTING. THIS IS ESSENTIAL
TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE
DESIRED NC LEVELS WITHIN ROOMS.
12. WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED
OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL
RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.
13. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
14. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
15. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.
16. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL
EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.
17. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER
NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
18. CONTRACTOR TO COORDINATE SCHEDULE OF ANY NOISE-PRODUCING WORK SCOPE WITH
COR NOT LESS THAN 10 DAYS PRIOR TO COMMENCING WORK.
19. ALL CARTS, EQUIPMENT, MATERIAL AND TOOLS AS WELL AS ALL TOOL BAGS/BOXES AND
LADDERS ARE TO BE LABELED, CLEARLY IDENTIFYING THE CONTRACTOR/SUBCONTRACTOR
NAME AND PROJECT.
20. STORAGE OF TOOLS, EQUIPMENT AND MATERIALS IS ONLY AUTHORIZED IN APPROVED
LOCATIONS.
EXISTING T'STAT
VAV-132
EXISTING DRAIN
PAN & PIPE
EXISTING RA GRILLE
EXISTING SA
REGISTER
EXISTING RACK
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/2
/2
:4
:5
P
M
115-M101
FIRST FLOOR DEMOLITION -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
RDL DJC
12345
KEYNOTES 1/115-M101:
1. EXISTING DRIP PANNED 3" HYDRONIC HEATING PIPE TO BE
REMOVED AS SHOWN FOR REROUTING.
2. EXISTING SUPPLY AIR DIFFUSER TO BE REMOVED. CAP
DUCT.
3. EXISTING RETURN AIR GRILLE TO BE REMOVED. CAP DUCT.
4. EXISTING THERMOSTAT TO BE DISCONNECTED AND
REMOVED.
5. 3/4" DRAIN TO FLOOR TO BE REMOVED.
1/2" = 1'-0"
FIRST FLOOR DEMOLITION - MECHANICAL - EXIST 107
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT
THEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN
SCOPE OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF EXISTING THERMOSTATIC CONTROL DEVICES
E. SIZE AND LOCATION OF EXISTING PLUMBING AND HYDRONIC PIPING.
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS, AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO THEIR BID AND INCLUDE
IN THEIR BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. ANY DISCREPANCIES WHICH MAY AFFECT CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION
0 2' 4'1'
N
100% CD 03/30
24706
03/30/2022
T
DESK
30X66
LAT. FILE
18X42
B O
O K
S
CORRIDOR
CORRIDOR
103-2
CORRIDOR
LOCKERS
104C
ELEC
STAFF LOUNGE
104D
STAFF TLT
104B NEW WALL MOUNTED
DUCTLESS COOLING
UNIT AC-115-1
PROPOSED RACK
LOCATIONS
CP-115-1
DRIP PAN CONDENSATE
PIPING IN ROOM
AC-115-1
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES AND COR PRIOR TO INSTALLATION TO
PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE,
AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE COR AND THE ARCHITECT/ENGINEER BEFORE
PROCEEDING WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER
ACCESS. FINAL LOCATIONS TO BE ACCURATELY DESCRIBED IN AS-BUILTS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST, TIME OR
EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
7. REFER TO CONTRACT DOCUMENTS, TO INCLUDE BUT NOT LIMITED TO, THE
ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIO/VISUAL, AND
OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES,
OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO THE SATISFACTION OF THE COR TO MATCH ORIGINAL
CONSTRUCTION, FIRE RATING, AND FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
COR FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE
PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE COR OF THE REQUIRED ACCESS
PANELS PRIOR TO BIDDING.
10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING,
AND DUCTS PENETRATE, BOTH NEW AND EXISTING. PENETRATIONS THROUGH EXTERIOR
WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH WATERPROOFING MATERIALS
RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL,
PARTITION, FLOOR, AND ROOF ASSEMBLIES, BOTH NEW AND EXISTING. THIS IS ESSENTIAL
TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE
DESIRED NC LEVELS WITHIN ROOMS.
12. WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED
OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL
RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.
13. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
14. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
15. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.
16. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL
EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.
17. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER
NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
18. CONTRACTOR TO COORDINATE SCHEDULE OF ANY NOISE-PRODUCING WORK SCOPE WITH
COR NOT LESS THAN 10 DAYS PRIOR TO COMMENCING WORK.
19. ALL CARTS, EQUIPMENT, MATERIAL AND TOOLS AS WELL AS ALL TOOL BAGS/BOXES AND
LADDERS ARE TO BE LABELED, CLEARLY IDENTIFYING THE CONTRACTOR/SUBCONTRACTOR
NAME AND PROJECT.
20. STORAGE OF TOOLS, EQUIPMENT AND MATERIALS IS ONLY AUTHORIZED IN APPROVED
LOCATIONS.
CU-115-1
MECHANICAL RENOVATION NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD
SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND
REPORT ANY CONFLICTS BEFORE PROCEEDING.
2. NOT ALL EXISTING DUCTWORK AND PIPING IS SHOWN. VERIFY EXISTING CONDITIONS
BEFORE STARTING WORK. NOTIFY COR AND ENGINEER OF ANY CONFLICTS WITH NEW
WORK.
3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR DUCTWORK AND PIPING BEFORE
FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD
CONDITIONS.
4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS/HER WORK
AND SHALL NOTIFY THE COR AND ENGINEER PRIOR TO BIDDING IF OTHER UTILITIES ARE
REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF
WORK.
5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF
ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS.
CONTRACTORS SHALL NOTIFY THE COR AND ENGINEER OF AFFECTED AREAS PRIOR TO
BIDDING.
6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL
CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO
BIDDING.
7. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH
NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL
EITHER ARRANGE NEW EQUIPMENT, PIPING, OR DUCTWORK IN SUCH A FASHION THAT IT
DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING SYSTEMS TO ALLOW
FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.
8. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING
CONSTRUCTION. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT
REMAIN ACTIVE.
9. OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY
REASON. MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL NEW
SYSTEMS ARE INSTALLED.
10. MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR
TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS AND
CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLY OR COMPLETELY
DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH MINIMUM OUTAGE.
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/2
/2
:5
:0
P
M
115-M201
FIRST FLOOR - MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
RDL DJC
12345
KEYNOTES, 1/115-M201:
1. REROUTE EXISTING 3" HYDRONIC HEATING PIPE - FIELD VERIFY EXACT
REQUIREMENTS.
2. NEW SPLIT SYSTEM AC UNIT.
3. ROUTE REFRIGERANT PIPING TO NEW AIR-COOLED CONDENSING UNIT
LOCATED AT EAST EXTERIOR OF BUILDING. SEE 2/115-M201.
4. ROUTE 1" CONDENSATE PIPING TO FLOOR DRAIN IN MECHANICAL ROOM 159,
APPROXIMATELY 30 FT NORTH.
5. NEW THERMOSTAT.
6. NEW FIRE-SPRINKLER HEAD AND BRANCH PIPE. CONNECT TO SPRINKLER MAIN
IN CORRIDOR. FIELD VERIFY REQUIREMENTS.
1/2" = 1'-0"
FIRST FLOOR - MECHANICAL
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT T
HEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN
SCOPE OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF EXISTING THERMOSTATIC CONTROL DEVICES
E. SIZE AND LOCATION OF EXISTING PLUMBING AND HYDRONIC PIPING.
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS, AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO THEIR BID AND INCLUDE
IN THEIR BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. ANY DISCREPANCIES WHICH MAY AFFECT CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION
1/2" = 1'-0"
FIRST FLOOR - MECHANICAL - CONDENSING UNIT
KEYNOTES, 2/115-M201:
1. ROUTE REFRIGERANT PIPING FROM AIR COOLED CONDENSING UNIT TO RM
108AC UNIT. FIELD COORDINATE EXACT ROUTING REQUIREMENTS.
2. NEW CONDENSING UNIT ON GRADE. PROVIDE CONCRETE PAD.
N N
0 2' 4'1'0 2' 4'1'
100% CD 03/30
24706
03/30/2022
| 115-GI000 - BUILDING 115 COVER SHEET & SHEET INDEX |
| 115-GI111 - FIRST FLOOR - INFECTION CONTROL & PHASING PLAN |
| 115-AS110 - FIRST FLOOR PLANS |
| 115-TD110 - FIRST FLOOR PLAN - TELECOM - DEMOLITION |
| 115-TN110 - FIRST FLOOR PLAN - TELECOMMUNICATIONS |
| 115-TN210 - FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE |
| 115-TN400 - ENLARGED PLANS - TELECOMMUNICATIONS |
| 115-E201 - FIRST FLOOR - ELECTRICAL |
| 115-E300 - ELECTRICAL ENLARGED PLANS |
| 115-M101 - FIRST FLOOR DEMOLITION - MECHANICAL |
| 115-M201 - FIRST FLOOR - MECHANICAL |
File details come from the government source that posted it. Updated .