Atch 11 - BLDG 5 addendum.pdf

PDF 9 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
Solicitation number
36C77622B0035
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This solicitation is for construction services to complete infrastructure upgrades at the St. Cloud Veterans Affairs Health Care System campus. Required work includes electrical upgrades, access security, HVAC renovations and expansions, data center physical security enhancements, fiber infrastructure installation within and between buildings, and hazardous materials abatement. The contractor must furnish all labor, materials, tools and equipment to perform the upgrades in accordance with contract drawings and specifications. The Department of Veterans Affairs Technology Acquisition Center Austin is the contracting agency.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud, newest first.
File Type Posted
36C77622B0035 0003.pdf PDF
Atch 41 - Construction Wage Rates - Stearns 7-29-22.pdf PDF
36C77622B0035 0002.pdf PDF
Technical Questions - FINAL - St. Cloud 7-28-22.pdf PDF
Atch 2 - Specifications Volume 2 addendum.pdf PDF
Atch 7 - BLDG 1 - 2 of 2 addendum.pdf PDF
Atch 16 - BLDG 10 addendum.pdf PDF
Atch 19 - BLDG 28 addendum.pdf PDF
Atch 23 - BLDG 50 addendum.pdf PDF
Atch 26 - BLDG 95 and 88 addendum.pdf PDF
Atch 29 - BLDG 109 and 57 addendum.pdf PDF
Atch 34 - BLDG 118 addendum.pdf PDF
Atch 35 - ADHC addendum.pdf PDF
Atch 36 - Parking Structure addendum.pdf PDF
Atch 3 - Specifications Volume 3 - Asbestos addendum.pdf PDF
Atch 4 - General 1 of 2 addendum.pdf PDF
Atch 6 - BLDG 1 - 1 of 2 addendum.pdf PDF
Atch 8 - BLDG 2 addendum.pdf PDF
Atch 9 - BLDG 3 addendum.pdf PDF
Atch 12 - BLDG 6 addendum.pdf PDF
Atch 13 - BLDG 7 and 13 addendum.pdf PDF
Atch 27 - BLDG 96 addendum.pdf PDF
Atch 30 - BLDG 111 addendum.pdf PDF
Atch 31 - BLDG 112 addendum.pdf PDF
Atch 2 - Specifications Volume 2.pdf PDF
Atch 3 - Specifications Volume 3 - Asbestos.pdf PDF
Atch 9 - BLDG 3.pdf PDF
Atch 11 - BLDG 5.pdf PDF
Atch 13 - BLDG 7 and 13.pdf PDF
Atch 14 - BLDG 8.pdf PDF
Atch 17 - BLDG 11.pdf PDF
Atch 29 - BLDG 109 and 57.pdf PDF
Atch 33 - BLDG 116.pdf PDF
Atch 37 - Brand Name Justification - St. Cloud.pdf PDF
Atch 38 - Contractor Core Work Hours.pdf PDF
Atch 39 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 41 - Construction Wage Rates - Stearns 4-1-22.pdf PDF
Atch 42 - Contractor Safety - Environmental Form.docx DOCX document
36C77622B0035 - 6-9-22.pdf PDF
Atch 6 - BLDG 1 - 1 of 2.pdf PDF
Atch 16 - BLDG 10.pdf PDF
Atch 19 - BLDG 28.pdf PDF
Atch 22 - BLDG 49.pdf PDF
Atch 35 - ADHC.pdf PDF
Atch 4 - General 1 of 2.pdf PDF
Atch 5 - General 2 of 2.pdf PDF
Atch 8 - BLDG 2.pdf PDF
Atch 23 - BLDG 50.pdf PDF
Atch 24 - BLDG 51.pdf PDF
Atch 27 - BLDG 96.pdf PDF
Show all 50

Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEGEND

CORRIDOR OUTLINE

VFY EXIST

BUILDING OUTLINE

VFY EXIST

TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST

44TH AVE.

TRAIL 1

TRAIL 2

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2)

15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

GRAVEL

GRAVEL

GRAVEL

EXISTING

ROAD

CHAIN LINK FENCE

CHAIN LINK FENCE

16' GATE

GRAVEL

ELECTRICAL

SUBSTATION

G E N E R A T O R

FUEL LINES

CONDU ITS TO TU NNEL

M V

D U

C T

B A

N K

1 1 2 W 11 2 E

G E N E R A T O R

B

CORRIDOR LINK

A

C T

TR

A

IL

ER

174 s .f.

256 s .f.

185 s .f.

149 s ..f.

155 s .f.

104 s .f.

70 s. .f .

72 s .f.

110 s .f.

276 s .f.

112 s .f.

99 s .f.

57 s .f.

146 s .f.

434 s .f.

R A

MP

U P

1:

M A X

R A

MP

U P

1:

M A X

RA

M P

UP

1:2 0 M

AX

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2) 15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

.3

TRANSFORMER

BUILD ING

#91

5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN

O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW

C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D

P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S

R EC O M M EN D ATIO N S

N EW G AS SU P P LY M AIN

IN TO B U ILD IN G

SP AR E

P H O N E LIN E

EXTEN D S TO

E XISTIN G

P H O N E IN

B O ILER R O O M

P ER P LAN .

SP AR E

P H O N E

LIN E TO

M ETER

TU N N EL

E XTEN D S

A D D ITIO N AL

2'- 0" U N D ER

B U ILD IN G

FUEL LINE

VENT LINE

1,000 GAL.

UNDERGROUND

DIESEL FUEL

TANK

1,000/5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

S 1

LIG H T

N EW G AS SU P P LY

(C O O R D IN ATE W ITH SU P P LIER )

12"D

10"D

"D

TP TP

EXIST. BUILDING

EXIST.

BUS STOP

CC

L O

O P

16"

20"

12"

3"

8"

DN

0.

0’

BIRDCAGE

B

IR

D C

A G

E

NSP ELECTRICAL

FOR HWY DEPT

T101

I.T.

CHILLER

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

VESTIBULE

DN

DN

DN

FD

DN

F B

F

B

F B

F

B

F B

F

B

SOUTH

VESTIBULE

PASS

THROUGH

LINK TO

BUILDI NG 51

6 3. 32 56

1 13 5. 35 78

PARKING

NO

PARKING

93 49

37 6

109 5

1A

S M

O K

E B

L D

G

SMOKE

BLDG

SMOKE

BLDG

S M

O K

E B

L D

G

SMOKE

BLDG

M.H.

STOR.

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

STOR.

BIO-

HAZ.

SAUK RIVER

GP

HOLDING POND

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

OWNER AND

CONSULTANTS:

CONTACT:

ADDRESS:

MIKE ENGMARK

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

NAME:

ADDRESS:

CONTACT:

ADVANCED STRUCTURAL TECHNOLOGIES

7301 OHMS LANE; SUITE 215

EDINA, MN 55439

ZACHARY CRAIG

PHONE:

NAME:

ADDRESS:

CONTACT:

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

PHONE: 402-991-5520

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

IAN WEBER

763-412-4000

ARCHITECT:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

EDWARD MARKFORT

763-412-4000

952-854-9302

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

402-991-5520

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

COVER

DATE:

APPROVED: APPROVED: PROJECTS SECTION MANAGER

APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:

APPROVED: SAFETY MANAGER

APPROVED: CHIEF OF POLICE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE: APPROVED: EMS MANAGER

APPROVED: M/O MANAGER

DATE:

DATE:

DATE:DATE:

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: PROJECT COR DATE:

APPROVED: INFECTION CONTROL NURSE DATE:

APPROVED: SERVICE LINE DIRECTOR

APPROVED: GEMS COORDINATOR DATE:

DATE:

APPROVED: NURSE EXECUTIVE

APPROVED: CHIEF OF STAFF DATE:

APPROVED: DIRECTOR FMS

APPROVED: ASSOCIATE DIRECTOR

DATE:

DATE:

DATE:

DATE:APPROVED: DATE:

APPROVED: DATE:

APPROVED: DATE:

Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System

N

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

VICINITY MAP:

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHONE: 320-252-1670

CIVIL ENGINEER:

VA COR:

TELECOMMUNICATIONS ENGINEER:

CONTACT:

ADDRESS:

JONATHAN WEST

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

PHONE: 504-250-2699

PROGRAM MANAGER:

EMAIL: Jonathan.West@vciint.com

STRUCTURAL ENGINEER:

MECH/ELEC/PLUMB/FIRE ENGINEER:

C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -5

-R E

M a rk fo rt

.r v t

/2

/2

:0

:4

P

M

5-GI000

BUILDING 5 COVER SHEET &

SHEET INDEX

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

BUILDING 5 - EHRM INFRASTRUCTURE UPGRADES

03/30/2022

0APPROX 150' 300'75'

SHEET INDEX - BUILDING 5

SHEET NO. SHEET TITLE

5-GI000 BUILDING 5 COVER SHEET & SHEET INDEX

5-GI110 FIRST LEVEL LIFE SAFETY PLAN

5-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN

5-AS110 FIRST FLOOR PLANS

5-AS500 SECTIONS, DETAILS

5-AS600 ELEVATIONS, DETAILS

5-S110 FIRST FLOOR PLANS

5-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION

5-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS

5-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

5-TN400 ENLARGED PLANS - TELECOMMUNICATIONS

5-TN300 ENLARGED PLANS - TELECOMMUNICATIONS - DEMO

05-E200 FIRST FLOOR PLAN - ELECTRICAL

05-E300 ELECTRICAL ENLARGED PLANS

05-E400 ELECTRICAL ONE-LINE DIAGRAMS

05-E500 ELECTRICAL SCHEDULES

05-M101 FIRST FLOOR DEMOLITION - MECHANICAL

05-M201 FIRST FLOOR REMODEL - MECHANICAL

SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION

ROOM SCHEDULE

NO. NAME C

A

B

LI

N G

P A

T C

H P

A N

E L

F

IB

E R

P O

W E

R

B O

N D

IN

G

U P

S

D E

D

IC

A T

E D

C O

O

LI

N G

T E

M P

E R

A T

U R

E

H U

M

ID

IT

Y

R A

C K

S E

N S

O R

S P

A C

E

AREA

WIDTH

(FT)

LENGTH

(FT)

HT TO

CLG

STRUCT REMARKS

FIRST FLOOR

114 EXIST RM 51 SF 5.4 9.6 8.00 DECOMMISSION EXIST IT/DATA ROOM. SEE TELECOM

DRAWINGS. CONVERT TO CORRIDOR FOR TR BUILDING

ADDITION

116 TELECOM ROOM X X X X X X X X X X X 120 SF 12.0 10.0 10.00 CONSTRUCT ADDITION. CONSTRUCT TO EHRM

TELECOM ROOM STANDARDS. SEE STRUCTURAL AND

TELECOM DRAWING

PROPOSED ADDITION

HAZARDOUS MATERIAL SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

QUESTIONABLE HAZARDOUS

ELEMENT POSSIBLE ABATEMENT ACTION

FIRST FLOOR 114 EXIST RM NONE NONE

FIRST FLOOR 116 TELECOM ROOM NONE NONE, BUILDING ADDITION

HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT DISTURB

QUESTIONABLE HAZARDOUS MATERIAL.

OPENING SCHEDULE

VA Building Number

ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION

H D

W G

R O

U P

F

IR

E L

A B

E L

(M

IN

G A

S K

E T

E

LE

C T

R

IC

A L

S L

A B

E L

COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT

PANEL

TYPE

2ND

PANEL

TYPE

PANEL

GLAZING FRAME TYPE

FRAME

GLAZING

5 EXIST RM TELECOM ROOM 116 3'-0" 7'-0" HM-F NONE HMM-1 NONE HW-3.2B 45 Y Y Y

ICRA PHASE CONSTRUCTION ROOM SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

CAI BLDG NAME /

FUNCTION

CONSTRUCTION

PROJECT ACTIVITY

INFECTION CONTROL

RISK GROUP

CONTROL

PROCEDURE CLASS SECTION

CONSTRUCTION ZONE /

OCCUPIED CONSTR

DAY /

NIGHT

FIRST FLOOR 114 EXIST RM PHARMACY TYPE B GROUP 1 CLASS II CENTER ZONE5 DAY

FIRST FLOOR 116 TELECOM ROOM PHARMACY TYPE D GROUP 1 CLASS III/IV CENTER ZONE5 DAY

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

1 UPDATE TO BID DOCUMENTS 06/29/22

RX DISPENSING

AREA

ELECTRICAL

MECHANICAL

ROOM

WAITING

AREA

SECRETARY

OFFICE

101A

OFFICE

101B

OFFICE

MAIL

ROOM

OFFICE

101G

OFFICE

101F

STORAGE

109A

ELECTRICAL

RELEASE OF

INFORMATION

COPAY

PATIENT

FUNDS

WAITING

AREA

LOUNGE/

CONFERENCE

SECURITY

ROOM

OFFICE

101D

OFFICE

101C

IN-PATIENT

PHARMACY

TOILET

101E

HAC

TOILET

OUT-PATIENT

PHARMACY

VAULT

102A

HALL

C1B

SALLY

PORT

C1A

I.T.

VENDING

HD

COMPOUNDING

104A

HD

MEDICATIONS

IV

COMPOUNDING

104B

IV

MEDICATIONS

MECHANICAL

ANTI-ROOM

HAC

104C

TELECOM

ROOM

127' - 0"

TR

AV

EL

D

IS

TA

NC

E

'-0

TRAVEL DISTANCE

127'-0"

LIFE SAFETY SYMBOLS

SMOKE TIGHT

ASSEMBLY

1 HOUR FIRE

BARRIER

2 HOUR FIRE

BARRIER

3 HOUR FIRE

BARRIER

1 HOUR FIRE &

SMOKE BARRIER

2 HOUR FIRE &

SMOKE BARRIER

3 HOUR FIRE &

SMOKE BARRIER

HE

TRAVEL DISTANCE

100'-10"

TRAVEL DISTANCE

EA

EDEXIT EXIT

HORIZONTAL EXIT

EXIT DISCHARGE

EXIT ACCESS

FIRE

EXTINGUISHER

FE

FIRE

EXTINGUISHER

CABINET

FEC

LIMITS OF

CONSTRUCTION

SMOKE

COMPARTMENT

BOUNDARY

HEALTH CARE

SUITE

NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN

OCCUPANCY

SEPARATION

SHAFT

ADJACENT SYMBOLS SHOW PARTITION RATING AND

DAMPER REQUIREMENTS

HAZARDOUS USE

ADJACENT SYMBOLS SHOW PARTITION RATING.

OPENINGS REQUIRE CLOSER & LATCH

EXIT PASSAGEWAY

RATE AS STAIR

ALL OPENINGS TO BE RATED AS STAIR SHAFT

CORRIDOR

WALLS TO LIMIT THE TRANSFER OF SMOKE

ADJUNCT CORRIDOR or PSYCHIATRIC AREA or CONSTRUCTED WITH MIN. 4'-0" CLEAR

WITH (PER CHAPTER 19)

AREA SEPARATIONS / FIRE WALLS

TYPE(S) OF CONSTRUCTION

CONSTRUCTION TYPE

SEE LIFE SAFETY PLANS

(IBC CHAPTER 6) IBC II-B

CONSTRUCTION TYPE (EXISTING) (IBC CHAPTER 6) IBC II-B

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -5

-R E

M a rk fo rt

.r v t

/2

/2

:1 :1

P

M

5-GI110

FIRST LEVEL LIFE SAFETY

PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1/8" = 1'-0"

FIRST FLOOR LIFE SAFETY PLAN

N

0 8' 16'4'

NORTH

16x8 x

12x12 ø x

12x10

12x8

24x1224x12 24x12 x

20x14 x x

32x12 x

10x10

8ø x

42x14

18x14

10x10

12x8 x x ø

10x4

12x8

20ø x x

12x8

10x4

8ø

12ø

10ø ø

18ø

18x12 16x8

12x8 x

DN

RX DISPENSING

AREA

ELECTRICAL

MECHANICAL

ROOM

WAITING

AREA

SECRETARY

OFFICE

101A

OFFICE

101B

OFFICE

MAIL

ROOM

OFFICE

101G

OFFICE

101F

STORAGE

109A

ELECTRICAL

RELEASE OF

INFORMATION

COPAY

PATIENT

FUNDS

WAITING

AREA

LOUNGE/

CONFERENCE

SECURITY

ROOM

OFFICE

101D

OFFICE

101C

IN-PATIENT

PHARMACY

TOILET

101E

HAC

TOILET

OUT-PATIENT

PHARMACY

VAULT

102A

HALL

C1B

SALLY

PORT

C1A

I.T.

VENDING

HD

COMPOUNDING

104A

HD

MEDICATIONS

IV

COMPOUNDING

104B

IV

MEDICATIONS

MECHANICAL

ANTI-ROOM

HAC

104C

TELECOM

ROOM

ZONE 5

CONSTRUCTION / ICRA BARRIER

TEMPORARY DOOR

INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -5

-R E

M a rk fo rt

.r v t

/2

/2

:1 :0

P

M

5-GI111

FIRST FLOOR - INFECTION

CONTROL & PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1/8" = 1'-0"

FIRST FLOOR - CONST BARRIER PLAN

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

FIRST FLOOR 114 EXIST RM PHARMACY TYPE B GROUP 1 CLASS II

FIRST FLOOR 116 TELECOM ROOM PHARMACY TYPE D GROUP 1 CLASS III/IV

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

SEQUENCE OF EVENTS - ZONE 5

• SELECTIVE UPGRADE TO EXISTING INFORMATION TECHNOLOGY TO ENABLE

BUILDING TOTAL UPGRADE PROCESS

• INITIAL ICRA AND ILSM

• WITH THE EXCEPTION OF DOOR 116, CONSTRUCT ROOMS AS DIRECTED, SEE

ASSOCIATED DRAWINGS FROM STRUCTURAL, ELECTRICAL, MECHANICAL,

TELECOM, AND FINISHES

• PROVIDE TEMPORARY DOOR AT SOUTH WALL OF ADDITION

• SELECTIVE DEMOLITION TO ENABLE UPGRADES

• INSTALL COMMON CABLE INFRASTRUCTURE

• CONSTRUCT COMMUNICATION BACKBONE

• INSTALL CAT 6A

• INSTALL TEMPORARY PROTECTION AND CONDUCT SELECTIVE DEMOLITION TO

CONSTRUCT DOOR OPENING AND DOOR 116 ON EAST WALL OF ROOM.

• DEMOLISH TEMPORARY DOOR, TOOTH IN WALL, AND COMPLETE EXTERIOR

BUILDING FINISHES

• DECOMMISSION EXISTING NON-EHRM INFORMATION TECHNOLOGY ROOMS

SUGGESTED SEQUENCE. FINAL INSTALLATION SEQUENCE TO BE MADE AT A LATER DATE.

RX DISPENSING

AREA

ELECTRICAL

MECHANICAL

ROOM

WAITING

AREA

SECRETARY

OFFICE

101A

OFFICE

101B

OFFICE

MAIL

ROOM

OFFICE

101G

OFFICE

101F

STORAGE

109A

ELECTRICAL

RELEASE OF

INFORMATION

COPAY

PATIENT

FUNDS

WAITING

AREA

LOUNGE/

CONFERENCE

SECURITY

ROOM

OFFICE

101D

OFFICE

101C

IN-PATIENT

PHARMACY

TOILET

101E

HAC

TOILET

OUT-PATIENT

PHARMACY

VAULT

102A

HALL

C1B

SALLY

PORT

C1A

I.T.

VENDING

HD

COMPOUNDING

104A

HD

MEDICATIONS

IV

COMPOUNDING

104B

IV

MEDICATIONS

MECHANICAL

ANTI-ROOM

HAC

104C

'-4

'-8

TELECOM

ROOM

'-1

1/

2"

5' -4

/4

9'-6 3/4"

5-AS110

10'-0"

11'-8 1/4"

TELECOM

ROOM

5-AS600

'-4

5-AS600

EXIST RM

OFFICE

IN-03.01

5-AS500

5-AS500

5-AS500

CB12

CB12

5-AS500

5-AS500

REV

3' -4

3/ 4"

3'-7 75/128" 2'-6" 3'-8 53/128"

2' -1

/1

TELECOM

ROOM

TELECOM

ROOM

5-AS500

5-AS500

5-AS500

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -5

-R E

M a rk fo rt

.r v t

/2

/2

:1 :1

P

M

5-AS110

FIRST FLOOR PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR - OVERALL PLAN

1/4" = 1'-0"3

ENLARGED FLOOR PLAN

1/4" = 1'-0"2

PARTIAL DEMOLITION PLAN

1/4" = 1'-0"

REFLECTED CEILING PLAN

N

0 4' 8'2'

N

0 8' 16'4'

N

0 8' 16'4' 1/4" = 1'-0"

PARTIAL ROOF PLAN

DE12

FL2

RC1 RC2

_REFLECTED CEILING PLAN KEYED NOTES

RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET

ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE

VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET

ROW OR SECTION.

RC2 OPEN TO STRUCTURAL FLOOR ABOVE

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_FLOOR PLAN KEYED NOTES

FL1 4' BY 8' AC GRADE ¾” TRADE SIZE PLYWOOD BACKBOARD PAINTED

HIGH-GLOSS WHITE WITH TWO COATS OF FIRE RESISTANT PAINT FOR

SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA

FL2 DOOR, SIZE AS SCHEDULED, FIRE RESISTANT AS SCHEDULED

FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE

TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST

THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS

WITH FIRE CAULK.

FL4 PATCH TO MATCH FINISHES DISTURBED BY CONSTRUCTION TO MATCH

EXISTING; FLOOR AND WALL. CONTRACTOR TO PROVIDE LABOR AND

MATERIAL.

FL9 AT REMOVED TEMPORARY DOOR, TOOTH IN BLOCK.

FL10 EXIST BUILDING FIRE DEPARTMENT CONNECTION, MODIFY TO MAINTAIN

ACCESS.

FL17 PREFINISHED METAL DOWNSPOUT AND PRECAST CONCRETE SPLASH

BLOCK

FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_DEMOLITION PLAN KEYED NOTES

DE9 REMOVE AND SALVAGE EXISTING MASORNY WALL ASSEMBLY AS

REQUIRED FOR NEW DOOR INSTALLATION.

DE12 REFER TO STRUCTURE FOR EXCAVATION EXTENTS OF FOOTING AND

FOUNDATIONS.

DE17 PARTIALLY REMOVE SHINGLES , GUTTER, ALL ASSOCIATED SHEATHING

AND ROOF FRAMING ETC. AS REQUIRED FOR INSTALLATION OF NEW

ROOFING.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

FL1DE9

N

0 8' 16'4'

DE17

RO2

_ROOF PLAN KEYED NOTES

RO2 INSTALL RIDGE ROOF VENT TO THE EXTENTS SHOWN

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

FL17

FL3

FL10

FL20

FL4

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTORWITHIN TELECOM

ROOMS.

FL9

EXTERIOR WALL CB12

SEE 4/5-AS600

5-AS500

5-AS500

INTERIOREXTERIOR

FLOOR

1051.2

C

O U

R S

E S

9' -4

4"

TOP OF MASONRY WALL

BRICK LEDGE

BRICK

WATER VAPOR BARRIER

3" RIGID INSULATION

12" CMU

THROUGH WALL METAL FLASHING

FOUNDATION, REFER TO

STRUCTURE

6" GRANULAR BASE

CONC SLAB ON GRADE

FINISH FLOOR, REFER TO

FINISH SCHEDULE

2" PERIMETER INSULATION

R-10 MINIMUM

MORTAR NET

WEEP VENT AT 2' - 0" O.C.,

16" ABOVE FLASHING

FLOOR

1051.2

GROUND

1050.8

14" HIGH, CAST STONE

FACE UNIT, MATCH EXIST

PREFINISHED ALUMINUM GUTTER

FASCIA OVER FIRE RESITANT PLYWOOD

VENTED ALUMINUM SOFFIT

VAPOR BARRIER

EXTERIOR WALL, TYPE CB12

BATT INSULATION

ASPHALT SHINGLES

TOP OF MASONRY WALL

BOT OF FASCIA

1061.6

CONCRETE ROOF,

SEE STRUCT

UNDERLAYMENT

EXTERIOR EXPANSION JOINT, AS SPECIFIED

FIRE STOPPING MATERIAL, AS SPECIFIED.

EXISTING WALL CONSTRUCTION

SEE WALL SECTION

INTERIOR

EXTERIOR

VAPOR BARRIER

UNDERLAYMENT OVERLAPPED AT HIP

ASPHALT SHINGLES

HIP SHINGLE

ASPHALT SHINGLES

UNDERLAY

VALLEY METAL

4" MIN

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -5

-R E

M a rk fo rt

.r v t

/2

/2

:1 :2

P

M

5-AS500

SECTIONS, DETAILS EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1" = 1'-0"

EXTERIOR WALL - MASONRY

1 1/2" = 1'-0"

WALL SECTION - MASONRY AT FOOTING

1 1/2" = 1'-0"

WALL SECTION - ROOF EAVE

1 1/2" = 1'-0"

PLAN SECTION - FIRESTOPPING AT NEW WALL

1" = 1'-0"

ROOF HIP DETAIL

1 1/2" = 1'-0"

ROOF VALLEY DETAIL

5-AS500

1iCB12

WALL ASSEMBLY

4" FACEBRICK

2" AIR SPACE

3" RIGID INSULATION

BUILDING MEMBRANE

12" CMU - SEE STRUCTURAL

MASONRY TIE

1'-8 1/4"

8 5/8"11 5/8"

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -5

-R E

M a rk fo rt

.r v t

/2

/2

:1 :5

P

M

5-AS600

ELEVATIONS, DETAILS EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

_ELEVATION KEYED NOTES

EL1 EXISTING BUILDING ELEMENT, TO REMAIN

EL2 EXISTING WALL/PARTITION, PREPARE FOR MODIFICATION AS

PRESCRIBED BY PLAN

EL3 TELECOM ROOM ENCLOSURE TO MATCH EXISTING CONSTRUCTION

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

EXISTING CONDITION

EL3

EL3

EL2 EL2EL1

EL1

PERSPECTIVE VIEW FROM NORTHWEST

1/4" = 1'-0"

SOUTH ELEVATION - ROOM 114B

1/4" = 1'-0"

WEST ELEVATION - ROOM 114B

1 1/2" = 1'-0"

TYPES - WALL

EXIT

RX DISPENSING

AREA

ELECTRICAL

MECHANICAL

ROOM

WAITING

AREA

SECRETARY

OFFICE

101A

OFFICE

101B

OFFICE

MAIL

ROOM

OFFICE

101G

OFFICE

101F

STORAGE

109A

ELECTRICAL

RELEASE OF

INFORMATION

COPAY

PATIENT

FUNDS

WAITING

AREA

LOUNGE/

CONFERENCE

SECURITY

ROOM

OFFICE

101D

OFFICE

101C

IN-PATIENT

PHARMACY

TOILET

101E

HAC

TOILET

OUT-PATIENT

PHARMACY

VAULT

102A

HALL

C1B

SALLY

PORT

C1A

I.T.

VENDING

HD

COMPOUNDING

104A

HD

MEDICATIONS

IV

COMPOUNDING

104B

IV

MEDICATIONS

MECHANICAL

ANTI-ROOM

HAC

104C

OFFICE

I.T.

114B

TELECOM

ROOM

'-1

1/

2"

5' -4

/4

9'-6 3/4"

5-S110

NEW APPENDAGE AND

FOUNDATION PAD. 12" CMU

GROUTED SOLID WITH 4" BRICK

VENEER TO MATCH EXISTING

NEW DOOR OPENING AND HEADER

REQUIRED THROUGH EXIST. WALL

42" MIN DEPTH FOR FROST

PROTECTION OF FOUNDATION

CIP REINFORCED CONCRETE

ROOF CAST ON FORM DECK

9'-11 3/4"

'-4

'-4

'-1

0"

11'-8"

114B

TELECOM

ROOM

'-4

S500

S500

S600

S500

5" THICK SOG W/ #4

@ 12" O.C. EA WAY.

MID. OF SLAB

BOT. OF WALL FOOTING AT

42" BELOW TOP OF SOG.

11'-8"

S

S700

S700

S700

SHORING DESIGN BY OTHERS.

AT MINIMUM, SHORE DECK

AT 1/3 SPANS

L5X5X3/8 CONT. ANGLE TO EXIST.

MASONRY FOR 3C18 DECK SUPPORT.

1/2" DIA HILTI HIT -A ROD ANCHOR

@ 16" OC. INSTALL USING HILTI

HIT HY 70 ADHESIVE SYSTEM.

REMOVE BRICK VENEER AND VERIFY

8" MASONRY WALL TYPE

EXIST. 8" MASONRY WALL REQUIRED

TO HAVE EVERY OTHER CELL

GROUTED. KNOCK OUT SHELL FACE

ABOVE NEW ANGLE AND ADD FULLY

GROUTED CELLS AS REQUIRED

INDICATES 8" THICK CIP SLAB W/ #5 @ 12" O.C. TOP AND BOT. EACH WAY.

2" TOP AND BOT. COVER. SLAB MUST BE SHORED AS REQUIRED UNTIL

CONCRETE REACHES 7-% OF DESIGN STRENGTH

S

LIGHT GUAGUE TRUSSES BY OTHERS TO FRAME HIPPED ROOF ABOVE S2 ROOF SLAB.

3/4" PLYWOOD SHEATING. SEE ARCH FOR ROOF ASSEMBLY AND PROFILE.

1/8" = 1'-0"

FIRST FLOOR PLAN

3/8" = 1'-0"

ENLARGED FLOOR PLAN

3/8" = 1'-0"

ROOF PLAN

N

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

7301 OHMS LANE

SUITE #215

(952) 854-9302 TEL.

EDINA, MN 55439

ASTENG.COM

AST PROJECT NUMBER: MN 1964

03/30/2022

ZDC JRO

656-21-235

EHRM INFRASTRUCTURE

UPGRADES

C U s e rs

\j o b ri e n \D o c u m e n ts

\1

-5

-R jo b ri e n

K Q

E N

.r v t

/2

/2

:4

:4

A

M

5-S110

FIRST FLOOR PLANS

16305

SHEET NOTES:

1. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.

ANY EXISTING CONDITIONS THAT DIFFER FROM THOSE SHOWN ON THE STRUCTURAL DRAWINGS MUST

BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE STRUCTURAL ENGINEER (IN WRITING).

2. THE INFORMATION SHOWN ON THE DRAWING IS BASED ON THE EXISTING STRUCTURAL DRAWINGS, SURVEYED DATA AND PHOTOGRAPHS OF THE EXISTING BUILDING PROVIDED BY ARCH.

3. SEE ARCHITECTURAL PLANS FOR ALL OPENING LOCATIONS, DIMENSIONS AND INTERIOR PARTITIONS.

4. SEE PLAN, SCHEDULES AND SHEET S100 FOR DESIGN LOADS.

5. DO NOT CUT, CORE OR DEMOLISH ANY EXISTING BEAMS. OPENINGS MUST SHIFT TO AVOID AS-BUILT

LOCATION OF BEAMS.

6. ALL EXISTING PARTITIONS ARE ASSUMED TO BE OF LIGHT GAUGE CONSTRUCTION UNLESS NOTED

OTHERWISE. GC TO NOTIFY EOR IF DEMO WORK AT INTERIOR PARTITIONS CONTAIN

STRUCTURAL/ROLLED STEEL OR ARE OF MASONRY/CIP CONSTRUCTION.

7. ALL NEW OPENINGS GREATER THAN 5" IN DIAMETER OR 5"x5" ARE REQUIRED TO BE REINFORCED.

8. MASONRY WALL SHALL BE 12" BLOCK WITH #5 VERT BARS EACH FACE @ 16" OC UNLESS NOTED OTHERWISE.

REGISTRATION

LICENSE #:

I HEREBY CERTIFY THAT THIS PLAN,

SPECIFICATION, OR REPORT WAS

PREPARED BY ME OR UNDER MY

DIRECT SUPERVISION AND THAT I AM

A DULY LICENSED PROFESSIONAL

ENGINEER UNDER THE LAWS OF THE

STATE OF MINNESOTA.

PRINT NAME:

SIGNATURE:

DATE:

Zachary D. Craig

57219

RHC

1-2

RHC

1-3

RHC

1-4

RHC

1-5

RHC

1-6

VAV

1-19

VAV

1-20

101A

OFFICE

SECRETARY

101B

OFFICE

OFFICE

AREA

WAITING

PHARMACY

OUT-PATIENT

ROOM

MAIL

101G

OFFICE 101F

OFFICE

ELECTRICAL

MECHANICAL

ELECTRICAL

INFORMATION

RELEASE OF

COPAY

FUNDS

PATIENT

AREA

WAITING

CONFERENCE

LOUNGE/

ROOM

SECURITY

101D

OFFICE

101C

OFFICE

PHARMACY

IN-PATIENT

101E

TOILET

HAC

TOILET

102A

VAULT

C1B

HALL

C1A

PORT

SALLY

I.T.

VENDING

TOILET

104A

COMPOUNDING

HD

104B

COMPOUNDING

IV

MEDICATIONS

IV

ANTI-ROOM

104C

HAC

RHC

1-2

RHC

1-3

RHC

1-4

RHC

1-5

RHC

1-6

VAV

1-19

VAV

1-20

101A

OFFICE

SECRETARY

101B

OFFICE

OFFICE

AREA

WAITING

PHARMACY

OUT-PATIENT

ROOM

MAIL

101G

OFFICE 101F

OFFICE

ELECTRICAL

MECHANICAL

ELECTRICAL

INFORMATION

RELEASE OF

COPAY

FUNDS

PATIENT

AREA

WAITING

CONFERENCE

LOUNGE/

ROOM

SECURITY

101D

OFFICE

101C

OFFICE

PHARMACY

IN-PATIENT

101E

TOILET

HAC

TOILET

102A

VAULT

C1B

HALL

C1A

PORT

SALLY

I.T.

VENDING

TOILET

104A

COMPOUNDING

HD

104B

COMPOUNDING

IV

MEDICATIONS

IV

ANTI-ROOM

104C

HAC

C C C

C

C C

C

C

C

CC C

C

C C

C

CC

C

C

C

5-TN300

5-TN300

LIMITS OF DATA CABLING DEMOLITION

WAP WAP

WAP

WAP

WAP

WAP

WAP

4D 4D

4D

4D

4D

4D

4D

4D

D D D

4D

4D

2D 4D

4D

4D

4D

4D

4D

4D

4D

4D

4D/1

4D

4D

4D 4D

4D

4D

4D

4D

4D

4D

4D

4D

D

2D

2D

4D/2 4D

4D

4D 4D 4D 4D 4D

4D 4D

4D

4D

4D

4D

4D4D

4D

4D

4D

5D

5D

4D 4D4D4D

WAP

EE

E

E

E

E

E E

E

E E

EEEE

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E E

EE

E

E

E E

E E E E E

E

EE

E

E

E

E E

E

E

E E

E

E

E

EE

E

E

E

E

E

E E

E

E

E

E E

E

E

E

E

E

E

EEE

E

E

E

E

E

EE

E

E

E

E

E

E

E

E

E

E

E

E E

E

8" x2

"x

2"

"x 2"

"x

2"

8"x2"

8"x2"

12"x2"

"x

2"

8"x2"

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

5-TD110

FIRST FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOM - DEMOLITION

SHEET NOTES:

1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK

PLANS. REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW

CABLING ROUTES.

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

RX DISPENSING

AREA

ELECTRICAL

MECHANICAL

ROOM

WAITING

AREA

SECRETARY

OFFICE

101A

OFFICE

101B

OFFICE

MAIL

ROOM

OFFICE

101G

OFFICE

101F

ELECTRICAL

RELEASE OF

INFORMATION

COPAY

PATIENT

FUNDS

WAITING

AREA

LOUNGE/

CONFERENCE

SECURITY

ROOM

OFFICE

101D

OFFICE

101C

IN-PATIENT

PHARMACY

TOILET

101E

HAC

TOILET

OUT-PATIENT

PHARMACY

VAULT

102A

HALL

C1B

SALLY

PORT

C1A

I.T.

VENDING

HD

COMPOUNDING

104A

IV

COMPOUNDING

104B

IV

MEDICATIONS

ANTI-ROOM

HAC

104C

EXIT

EXIT

RX DISPENSING

AREA

ELECTRICAL

MECHANICAL

ROOM

WAITING

AREA

SECRETARY

OFFICE

101A

OFFICE

101B

OFFICE

MAIL

ROOM

OFFICE

101G

OFFICE

101F

ELECTRICAL

RELEASE OF

INFORMATION

COPAY

PATIENT

FUNDS

WAITING

AREA

LOUNGE/

CONFERENCE

SECURITY

ROOM

OFFICE

101D

OFFICE

101C

IN-PATIENT

PHARMACY

TOILET

101E

HAC

TOILET

OUT-PATIENT

PHARMACY

VAULT

102A

HALL

C1B

SALLY

PORT

C1A

I.T.

VENDING

HD

COMPOUNDING

104A

IV

COMPOUNDING

104B

IV

MEDICATIONS

ANTI-ROOM

HAC

104C

C C C

C

C C

C

C

C

CC C

C

C C

C

CC

C

C

C

5-TN400

1 114

EXIST RM

LIMITS OF DATA

CABLING REPLACEMENT

FROM ROOM 114B

4D

4D4D

4D

4D

4D

4D

4D

4D 4D

4D

4D

4D

D D D

WAP

WAP

WAP

4D

4D

4D

4D

4D 4D 4D

4D

4D 4D

4D

4D 4D

4D

4D 4D

4D

4D/1

4D/2 D

2D

2D

2D

WAP

4D

4D

WAP

WAP

4D

4D 4D 4D 4D 4D

4D

4D 4D

4D 4D

4D

4D

4D

4D

5D

5D

WAP

4D

4D

4D

4D

4D

4D

EE

E

E

E

E

E E

E

E E

EEEE

E

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E E

EE

E

E

E E

E E E E E

E

EE

E

E

E

E E

E

E

E E

E

E

E

EE

E

E

E

E

E

E E

E

E

E

E E

E

E

E

E

E

E

EEE

E

E

E

E

E

EE

E

E

"x

2"

"x

2"

12"x2"

E

WAP

TELECOM ROOM

4"

8"x2"

8" x2

8"x2"

8"x2"

"x

2"

E

E

E

E

E

E

E

E

E E

E

C4 126"

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

5-TN110

FIRST FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOMMUNICATIONS

SHEET NOTES:

1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

RX DI SPENSI NG

AREA

ELECTR I CAL

MECHAN I CAL

ROOM

WAI TI NG

AREA

SECR ETA RY

OFFI CE

101A

OFFI CE

101B

OFFI CE

MAI L

ROOM

OFFI CE

101G

OFFI CE

101F

ELECTR I CAL

RELEAS E OF

I NFORM ATI ON

COP AY

PATI ENT

FUN DS

WAI TI NG

AREA

LOUN GE/

CON FE RE NC E

SECUR I TY

ROOM

OFFI CE

101D

OFFI CE

101C

I N-PATI ENT

PHARM ACY

TOI L ET

101E

HAC

TOI L ET

OUT- PATI ENT

PHARM ACY

VAU LT

102A

HALL

C1B

SALLY

POR T

C1A

I.T.

VEND I NG

HD

COM POUN DI NG

104A

IV

COM POUN DI NG

104B

IV

MEDI CA TI ONS

ANTI -ROOM

HAC

104C

EXIT

EXIT

RX DI SPENSI NG

AREA

ELECTR I CAL

MECHAN I CAL

ROOM

WAI TI NG

AREA

SECR ETA RY

OFFI CE

101A

OFFI CE

101B

OFFI CE

MAI L

ROOM

OFFI CE

101G

OFFI CE

101F

ELECTR I CAL

RELEAS E OF

I NFORM ATI ON

COP AY

PATI ENT

FUN DS

WAI TI NG

AREA

LOUN GE/

CON FE RE NC E

SECUR I TY

ROOM

OFFI CE

101D

OFFI CE

101C

I N-PATI ENT

PHARM ACY

TOI L ET

101E

HAC

TOI L ET

OUT- PATI ENT

PHARM ACY

VAU LT

102A

HALL

C1B

SALLY

POR T

C1A

I.T.

VEND I NG

HD

COM POUN DI NG

104A

IV

COM POUN DI NG

104B

IV

MEDI CA TI ONS

ANTI -ROOM

HAC

104C

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

5-TN210

FIRST FLOOR PLAN -

TELECOM - CABLE DISTANCE

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1" = 30'-0"

FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

0 30' 60'15'

I.T.

I.T.

C

E E

RE

E

E E

D

R

TW

DATA RACK

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

5-TN300

ENLARGED PLANS -

TELECOMMUNICATIONS -

DEMO

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/4" = 1'-0"

ENLARGED PLAN - EXIST RM 114 - TELECOM DEMO

1/4" = 1'-0"

ENLARGED PLAN - TR 116 - TELECOM DEMO

0 4' 8'2'

N

N

0 4' 8'2'

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

SHEET NOTES:

1. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION.

EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK PLANS FOR SERVING

COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.

2. EXISTING CABLE TRAY, SECURITY CAMERAS, GROUND BUS BARS, AND RACKS FROM DECOMMISSIONED

ROOMS ARE TO BE REUSED, WHEN POSSBILE, IN NEW CONSTRUCTION TRS.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE

RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE

PROJECT.

1. ROOM 114

EXISTING CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 243

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

A C

C R

C

5-TN400

1 - a b

1 - c d

C4 126"

W

"x

4"

"x

4"

"x

4"

TELECOM ROOM

CABLE TRAY

DATA RACKS

12"x4"

12"x4"

E

E

4D/1 E

K E

Y P

A D

4"

AC

R

NOTES:

1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.

2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.

3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.

4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO

SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).

5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.

6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.

7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.

VERTICAL CABLE

MANAGEMENT (TYP)

RACK 1

1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT5E BACKBONE PATCH PANEL

1U CABLE MANAGEMENT

1U CABLE MANAGEMENT

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

CHANNEL RACK (TYP)

D

PROVIDE DATA CABLE TO RACK

MOUNTED UPS FOR CONNECTION

TO MONITORING SYSTEM

RACK 1

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

D

RACK 2

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

RACK 2

6U SPACE FOR FUTURE USE. PROVIDE BLANK

PANELS FOR UNUSED SPACES.

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

SPACE FOR FUTURE HORIZONTAL CABLE

DISTRIBUTION. PROVIDE BLANKING PANELS FOR

UNUSED SPACES.

6U SPACE FOR FUTURE USE. PROVIDE BLANK

PANELS FOR UNUSED SPACES.

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

SPACE FOR FUTURE HORIZONTAL CABLE

DISTRIBUTION. PROVIDE BLANKING PANELS FOR

UNUSED SPACES.

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

5-TN400

ENLARGED PLANS -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 2' 4'1'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.

THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED

FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE

PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.

1. ROOM 116

EXISTING CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 243 FROM 114

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6A): 243

DATA (CAT6): 0

1/2" = 1'-0"

ENLARGED PLAN - TR 116 - TELECOM - CABLE TRAY AND DATA

1/4" = 1'-0"

1 - a

1/4" = 1'-0"

1 - b

1/4" = 1'-0"

1 - c

1/4" = 1'-0"

1 - d

NOT TO SCALE

COMMUNICATIONS - TYPICAL TWO RACK ELEVATION WITH RACK MOUNT UPS - TR 116

SHEET NOTES:

1. PROVIDE A NEW ACCESS CONTROL PANEL TO BE INSTALLED IN THE TELECOM ROOM. THE CARD READER AND KEYPAD FOR THIS ROOM TO BE WIRED TO THE NEW ACCESS CONTROL PANEL. EXISTING CARD READERS AND KEYPADS WILL BE MOVED TO THE NEW CONTROL PANEL UNDER A DIFFERENT PROJECT.

E

EXIT

RX DISPENSING

AREA

ELECTRICAL

MECHANICAL

ROOM

WAITING

AREA

SECRETARY

OFFICE

101A

OFFICE

101B

OFFICE

MAIL

ROOM

OFFICE

101G

OFFICE

101F

STORAGE

109A

ELECTRICAL

RELEASE OF

INFORMATION

COPAY

PATIENT

FUNDS

WAITING

AREA

LOUNGE/

CONFERENCE

SECURITY

ROOM

OFFICE

101D

OFFICE

101C

IN-PATIENT

PHARMACY

TOILET

101E

HAC

TOILET

OUT-PATIENT

PHARMACY

VAULT

102A

HALL

C1B

SALLY

PORT

C1A

I.T.

VENDING

HD

COMPOUNDING

104A

HD

MEDICATIONS

IV

COMPOUNDING

104B

IV

MEDICATIONS

MECHANICAL

ANTI-ROOM

HAC

104C

TELECOM

ROOM

05-E300

05-E300

05-E300

CU-5-1

B5IT-1-4

WP

5-EC1-2-39,40

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:0

:4

A

M

05-E200

FIRST FLOOR PLAN -

ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

TBD GJL

16305

1/8" = 1'-0"

FIRST FLOOR PLAN - ELECTRICAL

KEYNOTES:

1. PROVIDE ELECTRICAL CONNECTION TO

CONDENSING UNIT, AS REQUIRED.

COORDINATE FINAL LOCATION AND

CONNECTION REQUIREMENTS WITH

MECHANICAL.

0 8' 16'4'

100% CD 03/30

SDE

ELECTRICAL

ELECTRICAL

TELECOM

ROOM

A

B5IT-1

A

5-EC1-1/40

TELECOM

ROOM

B5IT-1

AC-5-1

5-EC1-1/42

42"

B5IT-1-6

42"

5-EC1-1/42

42"

B5IT-1-6

42"

5-EC1-1/42

42"

B5IT-1-6

42"

5-EC1-1/37,39,41

B5IT-1-1,3,5

6 3

5ES-1

5-L1-1

5-L1-2

5EC-1-2-2

5EC-1-2-1

5EC-1

5MDP

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:0

:5

A

M

05-E300

ELECTRICAL ENLARGED

PLANS

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

TBD GJL

16305

1/4" = 1'-0"

FIRST FLOOR ENLARGED - TR

114B - LIGHTING

1 1/4" = 1'-0"

FIRST FLOOR ENLARGED -TR 114B

- POWER & SIGNAL

2 1/4" = 1'-0"

FIRST FLOOR ENLARGED - ELEC

110 - ELECTRICAL

KEYNOTES:

1. INDOOR UNIT TO BE POWERED BY OUTDOOR

UNIT. COORDINATE EXACT LOCATION WITH

M.C.

2. CONNECT SMOKE DETECTOR TO NEAREST

EXISTING SLC.

3. COORDINATE FINAL LOCATION OF

RECEPTACLE L21-30R WITH TELECOM

CONTRACTOR. PROVIDE 3/4"C-4#10, 1#10 GND

TO PANEL FOR EACH RECEPTACLE.

4. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-

PHASE,4-WIRE RACK MOUNTED UPS FOR EACH

RACK TOWER.

5. PROVIDE APC#AP8861 RPDU RACK PDU 2G

WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,

ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R

OUTLETS. PROVIDE TWO PER RACK, MOUNTED

PER MANUFACTURER'S REQUIREMENTS.

6. PROVIDE ONE RACK MOUNTED ZONE PDU

UNIT. 30 AMP 3 PHASE, 120/208V, 5-WIRE WITH

(4) L21-30R, (6) 5-20R AND TWO 10' POWER

CORDS. ZONIT#ZPDS-208V-30A-L21-4L21-20R-

CR.

SHEET NOTES:

1. REFER TO TECHNOLOGY PLANS FOR IT ROOM

LAYOUT AND RACK LAYOUT/DETAILS.

2. REFER TO SHEET 0-GE400 DETAIL FOR LAYOUT

& ONE-LINE OF RACK.

0 4' 8'2' 0 4' 8'2'

N N N

0 4' 8'2'

BASEMENT

FIRST FLOOR

NEW PANEL B5IT-1

100Y

5MDP

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:0

:5

A

M

05-E400

ELECTRICAL DIAGRAMS &

SCHEDULES

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

TBD GJL

16305

NO SCALE

PARTIAL POWER RISER

KEYNOTES:

1. PROVIDE NEW 100A/3P CIRCUIT BREAKER IN

EXISTING SWITCHBOARD TO MATCH EXISTING

TYPE AND AIC RATING.

100% CD 03/30

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 28.2 A

TOTAL CONNECTED AMPS: 28.21 A

Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 10.164 kVA

Power 9 kVA 100.00% 9 kVA TOTAL CONNECTED LOAD: 10.16 kVA

Lighting 0.444 kVA 100.00% 0.444 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 29.04 26.50 29.84

Total Load: 3.44 kVA 3.18 kVA 3.54 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --

-- 9 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 10 --

-- 7 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 8 --

-- 5 -- -- -- -- -- -- 3 0.54 1 20 A TELECOM ROOM REC. 6

-- 3 -- -- -- -- -- -- 3 0.18 1 20 A WP GFI REC. 4

1 L21-30R RACK 30 A 3 3 0.44 1 20 A TELECOM ROOM LIGHTING 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.

SCCR: 10 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B5IT-1

5MDP

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/2

/2

:0

:5

P

M

05-E500

ELECTRICAL SCHEDULES

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

TBD GJL

16305

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 61.5 A

TOTAL CONNECTED AMPS: 61.48 A

Receptacles 1.26 kVA 100.00% 1.26 kVA TOTAL ESTIMATED DEMAND LOAD: 22.149 kVA

Power 20 kVA 100.00% 20 kVA TOTAL CONNECTED LOAD: 22.15 kVA

Lighting 0.889 kVA 100.00% 0.889 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 59.00 59.96 65.87

Total Load: 7.08 kVA 7.18 kVA 7.89 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

-- 11 -- -- -- -- -- -- 1 0.89 1 20 A TELECOM ROOM LIGHTING 12

9 CU-5-1 20 A 2 1 0.18 1 20 A WP GFI REC. 10

7 TELECOM ROOM REC. 20 A 1 0.54 0.54 1 20 A TELECOM ROOM REC. 8

-- 5 -- -- -- -- -- -- 3 3 -- -- -- -- -- -- 6 --

-- 3 -- -- -- -- -- -- 3 3 -- -- -- -- -- -- 4 --

1 L21-30R RACK 30 A 3 3 3 3 30 A L21-30R RACK 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.

SCCR: 10 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B5IT-1

5MDP

53095

T

OFFICE

ROOM

MAIL

I.T.

TOILET

KEYPLAN - FIRST FLOOR

NOT TO SCALE

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTA ARCHITECT/ENGINEER OF STAM

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 1

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.M

R

.r v t

/1

/2

:5

:1

A

M

05-M101

FIRST FLOOR

DEMOLITION -

MECHANICAL

EHRM

INFRASTRUCTURE

UPGRADES

656-21-235

RDL DJC

16305

1/4" = 1'-0"

FIRST FLOOR DEMOLITION - MECHANICAL - TELECOM 116

KEYNOTES 1/05-M101:

1. REMOVE AND DISPOSE OF EXISTING BASEBOARD FIN-TUBE

RADIATION AND CABINET. CAP PIPES IN WALL.

2. EXISTING RA GRILLE AND SA DIFFUSER TO REMAIN.

3. EXISTING THERMOSTAT TO REMAIN.

4. EXISTING FIRE SPRINKLER HEAD TO REMAIN.

FIELD VERIFICATION NOTES

1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT THEIR

BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:

A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE OF

WORK, WHETHER EXPLICITLY SHOWN OR NOT.

B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.

C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.

D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.

E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.

2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBLITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN THEIR

BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.

3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.

4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND

ARCHITECT FOR DIRECTION.

0 4' 8'2'

N

100% CD 03/3

OFFICE

MAIL

ROOM

I.T.

TELECOM

ROOM

CU-5-1

RACK PROVIDED

BY OTHERS

CUH-3

CP-5-1

AC-5-1

KEYPLAN - FIRST FLOOR

NOT TO SCALE

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTA ARCHITECT/ENGINEER OF STAM

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 1

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.M

R

.r v t

/1

/2

:5

:1

A

M

05-M201

FIRST FLOOR REMODEL -

MECHANICAL

EHRM

INFRASTRUCTURE

UPGRADES

656-21-235

RDL DJC

16305

N O R

HT

1/4" = 1'-0"

FIRST FLOOR - MECHANICAL - TELECOM 116

KEYNOTES 1/05-M201:

1. EXISTING RA GRILLE AND SA DIFFUSER TO REMAIN.

2. EXISTING THERMOSTAT TO REMAIN.

3. NEW WALL-MOUNTED COOLING UNIT AC-5-1.

4. ROUTE NEW REFRIGERANT PIPING TO CU-5-1 UNIT ON GRADE.

5. NEW AIR COOLED CONDENSING UNIT ON GRADE. PROVIDE NEW

CONCRETE PAD.

6. EXISTING FIRE SPRINKLER HEAD TO BE REMAIN.

7. NEW FIRE SPRINKLER HEAD. TIE INTO SPRINKLER MAIN IN CORRIDOR.

FIELD VERIFY EXACT LOCATION.

8. NEW THERMOSTAT - WIRE AS COMMON TO BOTH NEW AC UNIT

AND NEW CUH.

9. NEW HYDRONIC CABINET UNIT HEATER. REFERE TO DETAIL

4/0-GM400.

10. RE-ROUTE EXISTING HEATING WATER PIPING TO SERVE NEW CUH.

FIELD VERIFY REQUIREMENTS.

11. PIPE CONDENSATE TO MOP SINK LOCATED IN HAC ROOM, APPROX.

120 FEET NORTHEAST.

12. TIE NEW HEATING PIPING INTO EXISTING CAPPED LINES. FIELD VERIFY

REQUIREMENTS. FIELD VERIFY PIPE SIZES AND LOCATIONS.

13. PROVIDE CONDENSATE DRIP PANS FOR ALL CONDENSATE PIPING.

14. REFER TO 3/0-GM401 FOR UNIT MOUNTING DETAIL.

15. REFERE TO 4/0-GM401 FOR WALL PENETRATION SEALING DETAIL.

FIELD VERIFICATION NOTES

1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT THEIR

BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:

A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE OF

WORK, WHETHER EXPLICITLY SHOWN OR NOT.

B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.

C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.

D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.

E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.

2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBLITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN THEIR

BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.

3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.

4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND

ARCHITECT FOR DIRECTION.

N

0 4' 8'2'

100% CD 03/3

5-GI000 - BUILDING 5 COVER SHEET & SHEET INDEX
5-GI110 - FIRST LEVEL LIFE SAFETY PLAN
5-GI111 - FIRST FLOOR - INFECTION CONTROL & PHASING PLAN
5-AS110 - FIRST FLOOR PLANS
5-AS500 - SECTIONS, DETAILS
5-AS600 - ELEVATIONS, DETAILS
5-S110 - FIRST FLOOR PLANS
5-TD110 - FIRST FLOOR PLAN - TELECOM - DEMOLITION
5-TN110 - FIRST FLOOR PLAN - TELECOMMUNICATIONS
5-TN210 - FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
5-TN300 - ENLARGED PLANS - TELECOMMUNICATIONS - DEMO
5-TN400 - ENLARGED PLANS - TELECOMMUNICATIONS
05-E200 - FIRST FLOOR PLAN - ELECTRICAL
05-E300 - ELECTRICAL ENLARGED PLANS
05-E400 - ELECTRICAL ONE-LINE DIAGRAMS
05-E500 - ELECTRICAL SCHEDULES
05-M101 - FIRST FLOOR DEMOLITION - MECHANICAL
05-M201 - FIRST FLOOR REMODEL - MECHANICAL