Atch 33 - BLDG 116 addendum.pdf

PDF 5 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
Solicitation number
36C77622B0035
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This federal contract solicitation seeks infrastructure upgrades at the St. Cloud Veterans Affairs Health Care System facilities. Required work includes electrical, bonding, UPS systems, building management system interfaces, access security, HVAC assessments and upgrades, data center and server room physical security enhancements, installation of a diversified fiber path to the data center for the WAN, and fiber infrastructure backbone upgrades within and between buildings. The solicitation also involves hazardous materials abatement. All work must be completed according to specifications and contract drawings. The contracting agency is the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud, newest first.
File Type Posted
Atch 41 - Construction Wage Rates - Stearns 7-29-22.pdf PDF
Technical Questions - LATE - St. Cloud 8-10-22.pdf PDF
01-M204 - ROOF REMODEL -MECHANICAL.pdf PDF
Atch 3 - Specifications Volume 3 - Asbestos addendum.pdf PDF
Atch 4 - General 1 of 2 addendum.pdf PDF
Atch 6 - BLDG 1 - 1 of 2 addendum.pdf PDF
Atch 8 - BLDG 2 addendum.pdf PDF
Atch 9 - BLDG 3 addendum.pdf PDF
Atch 12 - BLDG 6 addendum.pdf PDF
Atch 13 - BLDG 7 and 13 addendum.pdf PDF
Atch 27 - BLDG 96 addendum.pdf PDF
Atch 30 - BLDG 111 addendum.pdf PDF
Atch 31 - BLDG 112 addendum.pdf PDF
Specifications Addendum Information.pdf PDF
Drawings Addendum Information.pdf PDF
Atch 1 - Specifications Volume 1 addendum.pdf PDF
Atch 11 - BLDG 5 addendum.pdf PDF
Atch 17 - BLDG 11 addendum.pdf PDF
Atch 18 - BLDG 14 addendum.pdf PDF
Atch 28 - BLDG 108 addendum.pdf PDF
Site Visit Sign-in Sheets - 6-28-22 - 6-30-22.pdf PDF
36C77622B0035 - 6-9-22.pdf PDF
Atch 6 - BLDG 1 - 1 of 2.pdf PDF
Atch 16 - BLDG 10.pdf PDF
Atch 19 - BLDG 28.pdf PDF
Atch 22 - BLDG 49.pdf PDF
Atch 35 - ADHC.pdf PDF
Atch 4 - General 1 of 2.pdf PDF
Atch 5 - General 2 of 2.pdf PDF
Atch 8 - BLDG 2.pdf PDF
Atch 23 - BLDG 50.pdf PDF
Atch 24 - BLDG 51.pdf PDF
Atch 27 - BLDG 96.pdf PDF
Atch 31 - BLDG 112.pdf PDF
Atch 10 - BLDG 4.pdf PDF
Atch 34 - BLDG 118.pdf PDF
Atch 2 - Specifications Volume 2.pdf PDF
Atch 3 - Specifications Volume 3 - Asbestos.pdf PDF
Atch 9 - BLDG 3.pdf PDF
Atch 11 - BLDG 5.pdf PDF
Atch 13 - BLDG 7 and 13.pdf PDF
Atch 14 - BLDG 8.pdf PDF
Atch 17 - BLDG 11.pdf PDF
Atch 29 - BLDG 109 and 57.pdf PDF
Atch 33 - BLDG 116.pdf PDF
Atch 37 - Brand Name Justification - St. Cloud.pdf PDF
Atch 38 - Contractor Core Work Hours.pdf PDF
Atch 39 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 41 - Construction Wage Rates - Stearns 4-1-22.pdf PDF
Atch 42 - Contractor Safety - Environmental Form.docx DOCX document
Show all 50

Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEGEND

CORRIDOR OUTLINE

VFY EXIST

BUILDING OUTLINE

VFY EXIST

TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST

44TH AVE.

TRAIL 1

TRAIL 2

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2)

15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

GRAVEL

GRAVEL

GRAVEL

EXISTING

ROAD

CHAIN LINK FENCE

CHAIN LINK FENCE

16' GATE

GRAVEL

ELECTRICAL

SUBSTATION

G E N E R A T O R

FUEL LINES

CONDU ITS TO TU NNEL

M V

D U

C T

B A

N K

1 1 2 W

PHARMACY ADDITION

11 2 E

G E N E R A T O R

B

CORRIDOR LINK

A

C T

TR

A

IL

ER

174 s .f.

256 s .f.

185 s .f.

149 s ..f.

155 s .f.

104 s .f.

70 s. .f .

72 s .f.

110 s .f.

276 s .f.

112 s .f.

99 s .f.

57 s .f.

146 s .f.

434 s .f.

R A

MP

U P

1:

M A X

R A

MP

U P

1:

M A X

RA

M P

UP

1:2 0 M

AX

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2) 15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

.3

TRANSFORMER

BUILD ING

#91

5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN

O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW

C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D

P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S

R EC O M M EN D ATIO N S

N EW G AS SU P P LY M AIN

IN TO B U ILD IN G

SP AR E

P H O N E LIN E

EXTEN D S TO

E XISTIN G

P H O N E IN

B O ILER R O O M

P ER P LAN .

SP AR E

P H O N E

LIN E TO

M ETER

TU N N EL

E XTEN D S

A D D ITIO N AL

2'- 0" U N D ER

B U ILD IN G

FUEL LINE

VENT LINE

1,000 GAL.

UNDERGROUND

DIESEL FUEL

TANK

1,000/5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

S 1

LIG H T

N EW G AS SU P P LY

(C O O R D IN ATE W ITH SU P P LIER )

12"D

10"D

"D

TP TP

EXIST. BUILDING

EXIST.

BUS STOP

CC

L O

O P

16"

20"

12"

3"

8"

DN

0.

0’

BIRDCAGE

B

IR

D C

A G

E

NSP ELECTRICAL

FOR HWY DEPT

T101

I.T.

CHILLER

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

VESTIBULE

DN

DN

DN

FD

DN

F B

F

B

F B

F

B

F B

F

B

PASS

THROUGH

LINK TO

BUILDI NG 51

6 3. 32 56

1 13 5. 35 78

PARKING

NO

PARKING

93 49

37 6

109 5

1A

S M

O K

E B

L D

G

SMOKE

BLDG

SMOKE

BLDG

S M

O K

E B

L D

G

SMOKE

BLDG

M.H.

STOR.

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

STOR.

BIO-

HAZ.

SAUK RIVER

GP

HOLDING POND

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

OWNER AND

CONSULTANTS:

CONTACT:

ADDRESS:

MIKE ENGMARK

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

NAME:

ADDRESS:

CONTACT:

ADVANCED STRUCTURAL TECHNOLOGIES

7301 OHMS LANE; SUITE 215

EDINA, MN 55439

ZACHARY CRAIG

PHONE:

NAME:

ADDRESS:

CONTACT:

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

PHONE: 402-991-5520

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

IAN WEBER

763-412-4000

ARCHITECT:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

EDWARD MARKFORT

763-412-4000

952-854-9302

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

402-991-5520

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

COVER

DATE:

APPROVED: APPROVED: PROJECTS SECTION MANAGER

APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:

APPROVED: SAFETY MANAGER

APPROVED: CHIEF OF POLICE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE: APPROVED: EMS MANAGER

APPROVED: M/O MANAGER

DATE:

DATE:

DATE:DATE:

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: PROJECT COR DATE:

APPROVED: INFECTION CONTROL NURSE DATE:

APPROVED: SERVICE LINE DIRECTOR

APPROVED: GEMS COORDINATOR DATE:

DATE:

APPROVED: NURSE EXECUTIVE

APPROVED: CHIEF OF STAFF DATE:

APPROVED: DIRECTOR FMS

APPROVED: ASSOCIATE DIRECTOR

DATE:

DATE:

DATE:

DATE:APPROVED: DATE:

APPROVED: DATE:

APPROVED: DATE:

Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System

N

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

VICINITY MAP:

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHONE: 320-252-1670

CIVIL ENGINEER:

VA COR:

TELECOMMUNICATIONS ENGINEER:

CONTACT:

ADDRESS:

JONATHAN WEST

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

PHONE: 504-250-2699

PROGRAM MANAGER:

EMAIL: Jonathan.West@vciint.com

STRUCTURAL ENGINEER:

MECH/ELEC/PLUMB/FIRE ENGINEER:

C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -1

-R

E

M a rk fo rt

.r v t

/2

/2

:5

:0

P

M

116-GI000

BUILDING 116 COVER SHEET &

SHEET INDEX

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

BUILDING 116 - EHRM INFRASTRUCTURE UPGRADES

03/30/2022

0APPROX 150' 300'75'

SHEET INDEX - BUILDING 116

SHEET NO. SHEET TITLE

116-GI000 BUILDING 116 COVER SHEET & SHEET INDEX

116-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN

116-AS110 FIRST FLOOR PLANS

116-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION

116-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS

116-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

116-TN400 ENLARGED PLANS - TELECOMMUNICATIONS

116-E201 FIRST FLOOR - ELECTRICAL

116-E300 ELECTRICAL ENLARGED PLANS

116-M101 FIRST FLOOR DEMOLITION - MECHANICAL

116-M201 FIRST FLOOR REMODEL - MECHANICAL

SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION

ROOM SCHEDULE

NO. NAME C

A

B

LI

N G

P A

T C

H P

A N

E L

F

IB

E R

P O

W E

R

B O

N D

IN

G

U P

S

D E

D

IC

A T

E D

C O

O

LI

N G

T E

M P

E R

A T

U R

E

H U

M

ID

IT

Y

R A

C K

S E

N S

O R

S P

A C

E

AREA

WIDTH

(FT)

LENGTH

(FT)

HT TO

CLG

STRUCT REMARKS

FIRST FLOOR

111 TELECOM ROOM X X X X X X X X 61 SF 6.6 9.3 15.00 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM ROOM

STANDARDS. SEE TELECOM DRAWINGS

OPENING SCHEDULE

VA Building Number

ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION

H D

W G

R O

U P

F

IR

E L

A B

E L

(M

IN

G A

S K

E T

E

LE

C T

R

IC

A L

S L

A B

E L

COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT

PANEL

TYPE

2ND

PANEL

TYPE

PANEL

GLAZING FRAME TYPE

FRAME

GLAZING

HAZARDOUS MATERIAL SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

QUESTIONABLE HAZARDOUS

ELEMENT POSSIBLE ABATEMENT ACTION

FIRST FLOOR 111 TELECOM ROOM NONE NONE

HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT

DISTURB QUESTIONABLE HAZARDOUS MATERIAL.

ICRA PHASE CONSTRUCTION ROOM SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

CAI BLDG NAME /

FUNCTION

CONSTRUCTION

PROJECT ACTIVITY

INFECTION CONTROL

RISK GROUP

CONTROL

PROCEDURE CLASS SECTION

CONSTRUCTION ZONE /

OCCUPIED CONSTR

DAY /

NIGHT

FIRST FLOOR 111 TELECOM ROOM OUTPATIENT MENTAL

HEALTH

TYPE C GROUP 1 CLASS II WEST OCCUPIED CONSTRUCTION NIGHT

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

1 UPDATE TO BID DOCUMENTS 06/29/22

LOW VISION

CLINIC

NORTH

VESTIBULE

STAFF

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

MAILROOM

CORRIDOR

PT

CHARTING

GROUP

MTG ROOM

OP GYM

PT GYM

PROSTH.

STORAGE

EQUIP

STORAGE

PATIENT

TOILET

FEMALE

TOILET

MALE

TOILET

MECHANICAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRIDOR

WAITING

WAITING

SOUTH

VESTIBULE

RECEPTION

HAC

SCHEDULING

CLEAN

UTILITY

WC

STOR.

BALANCE

CLINIC

EQUIP

STORAGE

SPEECH

THERAPY

VIST

COORDINATOR

PROVIDER

OFFICE

LPN

REHAB

SUPERVISOR

CONSULTATION

ROOM

PROCEDURE

ROOM

O.T.

CHARTING

O.T.

CLINIC

CORRIDOR

CORRIDOR

ADL

BATHROOM

T-9

T-8

PATIENT

TOILET

SPEECH

THERAPY

ADL

KITCHEN

ADL

BEDROOM

154 SOILED

DN

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DW

REF.

154A

CLOSET

151A

CLOSET

DN

TELECOM

ROOM

INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -1

-R

E

M a rk fo rt

.r v t

/2

/2

:1 :2

P

M

116-GI111

FIRST FLOOR - INFECTION

CONTROL & PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1/8" = 1'-0"

FIRST FLOOR - CONST BARRIER PLAN

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

FIRST FLOOR 111 TELECOM ROOM OUTPATIENT MENTAL HEALTH TYPE C GROUP 1 CLASS II

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

N

0 8' 16'4'

NORTH

VESTIBULE

STAFF

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

MAILROOM

CORRIDOR

PT

CHARTING

GROUP

MTG ROOM

OP GYM

PT GYM

PROSTH.

STORAGE

EQUIP

STORAGE

PATIENT

TOILET

FEMALE

TOILET

MALE

TOILET

MECHANICAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRIDOR

WAITING

WAITING

SOUTH

VESTIBULE

RECEPTION

HAC

SCHEDULING

CLEAN

UTILITY

WC

STOR.

BALANCE

CLINIC

EQUIP

STORAGE

SPEECH

THERAPY

VIST

COORDINATOR

PROVIDER

OFFICE

LPN

REHAB

SUPERVISOR

CONSULTATION

ROOM

PROCEDURE

ROOM

O.T.

CHARTING

O.T.

CLINIC

CORRIDOR

CORRIDOR

ADL

BATHROOM

T-9

T-8

PATIENT

TOILET

SPEECH

THERAPY

ADL

KITCHEN

ADL

BEDROOM

154 SOILED

DN

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DW

REF.

154A

CLOSET

151A

CLOSET

DN

TELECOM

ROOM

6'-7 1/4"

9' -3

/4

116-AS110

TELECOM

ROOM

3' -6

/4

2'

-6

3' -2

/4

IN-03.01

TELECOM

ROOM

TELECOM

ROOM

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -1

-R

E

M a rk fo rt

.r v t

/2

/2

:1 :3

P

M

116-AS110

FIRST FLOOR PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR - OVERALL PLAN

1/4" = 1'-0"

ENLARGED FLOOR PLAN

1/4" = 1'-0"

DEMOLITION PLAN

1/4" = 1'-0"

REFLECTED CEILING PLAN

DE1

RC1 RC2

_DEMOLITION PLAN KEYED NOTES

DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM

REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_FLOOR PLAN KEYED NOTES

FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”

TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH

HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT

FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT

OVER FIRE RATING STAMP.

FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE

TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST

THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS

WITH FIRE CAULK.

FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_REFLECTED CEILING PLAN KEYED NOTES

RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET

ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE

VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET

ROW OR SECTION.

RC2 OPEN TO STRUCTURAL FLOOR ABOVE

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

N

0 4' 8'2'

N

0 4' 8'2'

N

0 4' 8'2'

DE1

DE1

FL1 FL20

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY THE VA) WITH WALL MOUNT BRACKET AND CODE

REQUIRED SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN

TELECOM ROOMS.

FL3

FL3

FL3

FL3

29 55

114 56

140140

177179 179

CLINIC

LOW VISION

VESTIBULE

NORTH

STAFF

THERAPY

SPEECH

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

TREATMENT

MAILROOM

CORRIDOR126

CHARTING

PT

MTG ROOM

GROUP

OP GYM

PT GYM 123

STORAGE

PROSTH.

STORAGE

EQUIP.

TOILET

PATIENT

TOILET

FEMALE

TOILET

MALE

MECHANICAL

VOLTAGE

LOW

ELECTRICAL

ELECTRICAL

CORRIDOR

WAITING

WAITING

VESTIBULE

SOUTH

RECEPTION

HAC

SCHEDULING

UTILITY

CLEAN

STOR.

WC

CLINIC

BALANCE

STORAGE

EQUIP.

THERAPY

SPEECH

COORDINATOR

VIST

OFFICE

PROVIDER

LPN

SUPERVISOR

REHAB

ROOM

CONSULTATION

ROOM

PROCEDURE

CHARTING

O.T. 156

CLINIC

O.T.

CORRIDOR

CORRIDOR

BATHROOM

ADL

T-9

T-8

TOILET

PATIENT

THERAPY

SPEECH

KITCHEN

ADL

BEDROOM

ADL

SOILED

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DWREF.

154A

CLOSET

151A

CLOSET

DN

29 55

114 56

140140

177179 179

CLINIC

LOW VISION

VESTIBULE

NORTH

STAFF

THERAPY

SPEECH

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

TREATMENT

MAILROOM

CORRIDOR126

CHARTING

PT

MTG ROOM

GROUP

OP GYM

PT GYM 123

STORAGE

PROSTH.

STORAGE

EQUIP.

TOILET

PATIENT

TOILET

FEMALE

TOILET

MALE

MECHANICAL

VOLTAGE

LOW

ELECTRICAL

ELECTRICAL

CORRIDOR

WAITING

WAITING

VESTIBULE

SOUTH

RECEPTION

HAC

SCHEDULING

UTILITY

CLEAN

STOR.

WC

CLINIC

BALANCE

STORAGE

EQUIP.

THERAPY

SPEECH

COORDINATOR

VIST

OFFICE

PROVIDER

LPN

SUPERVISOR

REHAB

ROOM

CONSULTATION

ROOM

PROCEDURE

CHARTING

O.T. 156

CLINIC

O.T.

CORRIDOR

CORRIDOR

BATHROOM

ADL

T-9

T-8

TOILET

PATIENT

THERAPY

SPEECH

KITCHEN

ADL

BEDROOM

ADL

SOILED

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DWREF.

154A

CLOSET

151A

CLOSET

DN

C

C

C

C

C

MAILROOM

RECEPTION

MAILROOM

RECEPTION

C

116-TD110

LIMITS OF DATA CABLING DEMOLITION

1D

2D

2D 2D

1D

2D

2D 2D

2D

2D

2D

2D

2D

2D

WAP

WAP

WAP

WAP

2D

2D

2D

WAP

2D

2D

2D

2D

2D2D2D

2D 2D 2D

2D 2D 2D

2D2D2D

1D

2D

2D

2D

E E E

EEE

E

E

E

E

E

E

E

E

E

E

E

EEE

E E E

E

E

E E

EE

E

E

E

E

E

E

E

E

E

E

E

E

EE

E

2D

2D

2D

E

E

E

2D

E

2D

2D

2D

E

E

E

2D E

E

E

E

E

2D

2D

2D

2D

E

E

E

E

WAP

2D

2D2D

2D E

E

E

E

E

2D

2D

2D

2DE

E

E 2D

WAP

2D

E

E 2D

E

EE

2D 2D

E

6D

EWAP

E E E

E

E E

E

EEE

E

E

E

E E

E

12"x2"

"x

2"

12"x2"

"x

2"

12"x2"12"x2"

"x

2"

"x

2"

12"x2"

"x

2"

"x 2"

12"x2"

E

E

"x

2"

E

DR

DR

SP D

D

D

E

DATA

RACKS

E

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/2

/2

:3

:5

A

M

116-TD110

FIRST FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

SHEET NOTES:

1. EXISTING TELECOMMUNICATIONS CAGE AND RACK SHALL BE INCLUDED WITHIN THE SCOPE OF DEMOLITION. EXISTING CABLING AND ASSOCIATED OUTLETS SHALL BE REMOVED AND REPLACED 1 FOR 1 AND REFED FROM DISTRIBUTION EQUIPMENT LOCATED WITHIN THE NEW TELECOMMUNICATIONS ROOM. REFER TO GENERAL CABLING NOTES FOR APPROXIMATE QUANTITIES. REFER TO NEW WORK

PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING ROUTES.

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOM - DEMOLITION

1/4" = 1'-0"

ENLARGED PLAN - EXIST RM 111 - TELECOM - DEMO

0 4' 8'2'

N

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE

RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE

PROJECT.

1. ROOM 111

EXISTING CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 114

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

NORTH

VESTIBULE

STAFF

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

MAILROOM

CORRIDOR

PT

CHARTING

GROUP

MTG ROOM

OP GYM

PT GYM

PROSTH.

STORAGE

EQUIP

STORAGE

PATIENT

TOILET

FEMALE

TOILET

MALE

TOILET

MECHANICAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRIDOR

WAITING

WAITING

SOUTH

VESTIBULE

RECEPTION

HAC

SCHEDULING

CLEAN

UTILITY

WC

STOR.

BALANCE

CLINIC

EQUIP

STORAGE

SPEECH

THERAPY

VIST

COORDINATOR

PROVIDER

OFFICE

LPN

REHAB

SUPERVISOR

CONSULTATION

ROOM

PROCEDURE

ROOM

O.T.

CHARTING

O.T.

CLINIC

CORRIDOR

CORRIDOR

ADL

BATHROOM

T-9

T-8

PATIENT

TOILET

SPEECH

THERAPY

ADL

KITCHEN

ADL

BEDROOM

154 SOILED

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DWREF.

154A

CLOSET

151A

CLOSET

DN

LOW VISION

CLINIC

NORTH

VESTIBULE

STAFF

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

MAILROOM

CORRIDOR

PT

CHARTING

GROUP

MTG ROOM

OP GYM

PT GYM

PROSTH.

STORAGE

EQUIP

STORAGE

PATIENT

TOILET

FEMALE

TOILET

MALE

TOILET

MECHANICAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRIDOR

WAITING

WAITING

SOUTH

VESTIBULE

RECEPTION

HAC

SCHEDULING

CLEAN

UTILITY

WC

STOR.

BALANCE

CLINIC

EQUIP

STORAGE

SPEECH

THERAPY

VIST

COORDINATOR

PROVIDER

OFFICE

LPN

REHAB

SUPERVISOR

CONSULTATION

ROOM

PROCEDURE

ROOM

O.T.

CHARTING

O.T.

CLINIC

CORRIDOR

CORRIDOR

ADL

BATHROOM

T-9

T-8

PATIENT

TOILET

SPEECH

THERAPY

ADL

KITCHEN

ADL

BEDROOM

154 SOILED

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DWREF.

154A

CLOSET

151A

CLOSET

DN

C

C

C

C

C

C

TELECOM ROOM

116-TN400

LIMITS OF DATA CABLING REPLACEMENT

FROM ROOM 111

1D

2D

2D

2D 2D

1D

2D

WAP

WAP

WAP

2D 2D

2D

2D

2D

2D

2D

2D

WAP

2D 2D 2D

2D2D2D 2D

2D 2D 2D

2D2D2D

1D

2D

2D

2D

2D

WAP

2D

2D

2D

2D

E E E

EEE

E

E

E

E

E

E

E

E

E

E

E

EEE

E E E

E

E

E E

EE

E

E

E

E

E

E

E

E

E

E

E

E

EE

E

2D

2D

2D

2D

2D

2D

2D

2D

E

E

E

E

E

E

E

E

E

E

2D

2D

2D E

E 2D

6D

E

E

E

E

E 2D

E

2D

E 2D

WAP

E

E 2D

2D

2D

2D

2D

E

E

E

E

E

2D

WAP

2D

E

E

2D E

2D 2D

EE

12"x2"

"x

2"

12"x2" 12"x2"

"x

2"

1 CABLE TRAY

E

WAP

4"

2"

2"

2"

2"

2"

2"

E E

E E

E

E

E E

E

EEE

E

E

E

E E

E

"x

2"

12"x2"

"x

2"

12"x2"

"x

2"

"x

2"

E

E

"x

2"

E

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/2

/2

:3

:5

A

M

116-TN110

FIRST FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

SHEET NOTES:

1. CONTRACTOR TO PROVIDE NEW WIRE BASKET OF EQUAL SIZE AND DISTANCE, EITHER BESIDE OR

BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY. NEW

HORIZONTAL CABLE, NEW COPPER BACKBONE, AND B SIDE FIBER ARE TO BE RUN IN THE NEW WIRE

BASKET.

2. PROVIDE JUNCTION BOX TO CONNECT FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO THE

NEW TELECOM ROOM.

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOMMUNICATIONS

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

NORTH

VESTIBULE

STAFF

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

MAILROOM

CORRI DOR

PT

CHARTING

GROUP

MTG ROOM

OP GYM

PT GYM

PROSTH.

STORAGE

EQUIP

STORAGE

PATIENT

TOILET

FEMALE

TOILET

MALE

TOILET

MECHANI CAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRI DOR

WAITING

WAITING

SOUTH

VESTIBULE

RECEPTION

HAC

SCHEDULING

CLEAN

UTILITY

WC

STOR.

BALANCE

CLINIC

EQUIP

STORAGE

SPEECH

THERAPY

VIST

COORDINATOR

PROVI DER

OFFICE

LPN

REHAB

SUPERVI SOR

CONSULTATION

ROOM

PROCEDURE

ROOM

O.T.

CHARTING

O.T.

CLINIC

CORRI DOR

CORRI DOR

ADL

BATHROOM

T-9

T-8

PATIENT

TOILET

SPEECH

THERAPY

ADL

KITCHEN

ADL

BEDROOM

154 SOILED

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DWREF.

154A

CLOSET

151A

CLOSET

DN

LOW VISION

CLINIC

NORTH

VESTIBULE

STAFF

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

MAILROOM

CORRI DOR

PT

CHARTING

GROUP

MTG ROOM

OP GYM

PT GYM

PROSTH.

STORAGE

EQUIP

STORAGE

PATIENT

TOILET

FEMALE

TOILET

MALE

TOILET

MECHANI CAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRI DOR

WAITING

WAITING

SOUTH

VESTIBULE

RECEPTION

HAC

SCHEDULING

CLEAN

UTILITY

WC

STOR.

BALANCE

CLINIC

EQUIP

STORAGE

SPEECH

THERAPY

VIST

COORDINATOR

PROVI DER

OFFICE

LPN

REHAB

SUPERVI SOR

CONSULTATION

ROOM

PROCEDURE

ROOM

O.T.

CHARTING

O.T.

CLINIC

CORRI DOR

CORRI DOR

ADL

BATHROOM

T-9

T-8

PATIENT

TOILET

SPEECH

THERAPY

ADL

KITCHEN

ADL

BEDROOM

154 SOILED

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DWREF.

154A

CLOSET

151A

CLOSET

DN

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/2

/2

:3

:5

A

M

116-TN210

FIRST FLOOR PLAN -

TELECOM - CABLE DISTANCE

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 30' 60'15' 1" = 30'-0"

FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

RECEPTIONRECEPTION

A C

C R

C

TELECOM ROOM

116-TN400

1 - a b

1 - c d

E

SP

12"x2"

12"x2"

12"x2"

C2 126"

12" LADDER

"x

2"

"x

2"

DATA RACK

CABLE TRAY

E

WKEYPAD

2"

FIRST FLOOR

0' - 0"

SECOND FLOOR

12' - 0"

FIRST FLOOR

0"

SECOND FLOOR

12'-0"

FIRST FLOOR

0' - 0"

SECOND FLOOR

12' - 0"

FIRST FLOOR

0"

SECOND FLOOR

12'-0"

FIRST FLOOR

0' - 0"

SECOND FLOOR

12' - 0"

FIRST FLOOR

0"

SECOND FLOOR

12'-0"

FIRST FLOOR

0' - 0"

SECOND FLOOR

12' - 0"

FIRST FLOOR

0"

SECOND FLOOR

12'-0"

VERTICAL CABLE

MANAGEMENT (TYP)

NOTES:

1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.

2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT

INSTALLATION.

3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.

4. CONTRACTOR TO PROVIDE PATCH PANELS AND HORIZONTAL CABLE MANAGEMENT TO

SUPPORT THE DATA COUNT ON THE WORK PLAN + 1 ADDITIONAL SPARE PATCH PANEL.

(NOT TO EXCEED 288 PORTS PER RACK).

5. SPARE RACKS WITH NO HARDWARE CONFIGURED IN THEM MUST HAVE THE STANDARD

UPS INSTALLED UNLESS THE ROOM HAS A CENTRAL UPS SOURCE.

6. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.

7. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS,

SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING

HARDWARE NOT MARKED AS “OIT PROVIDED”.PUNCHDOWN COPPER BACKBONES ON RACK

MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT

RACK 1

1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT5E BACKBONE PATCH PANEL

1U CABLE MANAGEMENT

1U CABLE MANAGEMENT

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

6U SPACE

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

CHANNEL RACK (TYP)

D

PROVIDE DATA CABLE TO RACK

MOUNTED UPS FOR CONNECTION

TO MONITORING SYSTEM

RACK 1

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

1U 48 PORT OIT SWITCH

2U CABLE MANAGEMENT

1U 48 PORT OIT SWITCH

1U 48 PORT OIT SWITCH

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

1U 48 PORT OIT SWITCH

2U CABLE MANAGEMENT

1U 48 PORT OIT SWITCH

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

1U 48 PORT OIT SWITCH

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/2

/2

:3

:5

A

M

116-TN400

ENLARGED PLANS -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 2' 4'1'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.

THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED

FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE

PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.

1. ROOM 111

EXISTING CABLE COUNT

DATA (CAT6): 0

DATA (CAT5e): 114

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6A): 114

DATA (CAT6): 0

1/2" = 1'-0"

ENLARGED PLAN -EXIST TR 111 - TELECOM - CABLE TRAY AND DATA

1/4" = 1'-0"

1 - a

1/4" = 1'-0"

1 - b

1/4" = 1'-0"

1 - c

1/4" = 1'-0"

1 - d

NOT TO SCALE

COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - EXIST TR 111

E

CLINIC

NORTH

VESTIBULE

STAFF

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

TREATMENT

ROOM 3

TREATMENT

ROOM 4

TREATMENT

ROOM 5

TREATMENT

ROOM 7

TREATMENT

ROOM 6

MAILROOM

CORRIDOR

PT

CHARTING

GROUP

MTG ROOM

OP GYM

PT GYM

PROSTH.

STORAGE

EQUIP

STORAGE

PATIENT

TOILET

FEMALE

TOILET

MALE

TOILET

MECHANICAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRIDOR

WAITING

WAITING

SOUTH

VESTIBULE

RECEPTION

HAC

SCHEDULING

CLEAN

UTILITY

WC

STOR.

BALANCE

CLINIC

EQUIP

STORAGE

SPEECH

THERAPY

VIST

COORDINATOR

PROVIDER

OFFICE

LPN

REHAB

SUPERVISOR

CONSULTATION

ROOM

PROCEDURE

ROOM

O.T.

CHARTING

O.T.

CLINIC

CORRIDOR

CORRIDOR

ADL

BATHROOM

T-9

T-8

PATIENT

TOILET

SPEECH

THERAPY

ADL

KITCHEN

ADL

BEDROOM

154 SOILED

DN

REF.

FDFD

FD

FD

FD

MALE TOILET

FEMALE

TOILET

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

CL LINEN

FD

FD

DWREF.

154A

CLOSET

151A

CLOSET

DN

TELECOM

ROOM

1 CU-116-1

116-E300

116-CR-8,10

116-L1-4

116-CR

116-L1-4-47

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/2

/2

:5

:4

P

M

116-E201

FIRST FLOOR - ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

TBD GJL

16305

KEYNOTES:

1. PROVIDE ELECTRICAL CONNECTION TO

CONDENSING UNIT, AS REQUIRED.

COORDINATE FINAL LOCATION AND

CONNECTION REQUIREMENTS WITH

MECHANICAL.

1/8" = 1'-0"

FIRST FLOOR - ELECTRICAL

0 8' 16'4'

N

100% CD 03/30

53095

GB

E

SD

MAILROOM

RECEPTION

UTILITY

TELECOM

ROOM

AC-116-1

116-CR-2,4,6

116-L1-4-49,51,53

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/2

/2

:5

:4

P

M

116-E300

ELECTRICAL ENLARGED

PLANS

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

TBD GJL

16305

1/4" = 1'-0"

FIRST FLOOR ENLARGED -

ELECTRICAL - RM 111

KEYNOTES:

1. DISCONNECT AND REMOVE LIGHTS AND

RECEPTACLES IN AREA OF NEW IT ROOM.

MAINTAIN CIRCUIT CONTINUITY TO ADJOINING

SPACES.

2. INDOOR UNIT TO BE POWERED BY OUTDOOR

UNIT. COORDINATE EXACT LOCATION WITH

M.C.

3. CONNECT SMOKE DETECTOR TO NEAREST

EXISTING SLC.

4. COORDINATE FINAL LOCATION OF

RECEPTACLE L21-20R WITH TELECOM

CONTRACTOR. PROVIDE 3/4"C-4#10, 1#12 GND

TO PANEL FOR EACH RECEPTACLE.

5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-

PHASE,4-WIRE RACK MOUNTED UPS FOR

EACH RACK TOWER.

6. PROVIDE APC#AP8861 RPDU RACK PDU 2G

WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,

ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R

OUTLETS. PROVIDE TWO PER RACK, MOUNTED

PER MANUFACTURER'S REQUIREMENTS.

SHEET NOTES:

1. REFER TO TECHNOLOGY PLANS FOR IT ROOM

LAYOUT AND RACK LAYOUT/DETAILS.

2. REFER TO SHEET 0-GE400 DETAIL LAYOUT &

ONE-LINE OF RACK.

0 4' 8'2'

N

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 19.4 A

TOTAL CONNECTED AMPS: 19.43 A

TOTAL ESTIMATED DEMAND LOAD: 7 kVA

TOTAL CONNECTED LOAD: 7.00 kVA

Power 7 kVA 100.00% 7 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 23.50 23.50 13.89

Total Load: 2.67 kVA 2.67 kVA 1.67 kVA

41 42

39 40

37 38

35 36

33 34

31 32

29 30

27 28

25 26

23 24

21 22

19 20

17 18

15 16

13 14

11 12

9 1 -- -- -- -- -- -- 10 --

7 1 2 20 A CU-116-1 8

5 1.67 -- -- -- -- -- -- 6 --

3 1.67 -- -- -- -- -- -- 4 --

1 1.67 3 30 A L21-30R 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

ISC UNKNOWN 0.00 kA

SCCR: 65 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

EXISTING PANEL 116-CR

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 14.4 A

TOTAL CONNECTED AMPS: 14.38 A

TOTAL ESTIMATED DEMAND LOAD: 5.18 kVA

Receptacles 0.18 kVA 100.00% 0.18 kVA TOTAL CONNECTED LOAD: 5.18 kVA

Power 5 kVA 100.00% 5 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 13.89 13.89 15.39

Total Load: 1.67 kVA 1.67 kVA 1.85 kVA

-- 53 -- -- -- -- -- -- 1.67 -- -- -- -- 1 -- SPACE 54 --

-- 51 -- -- -- -- -- -- 1.67 -- -- -- -- 1 -- SPACE 52 --

49 L21-30R 30 A 3 1.67 -- -- -- -- 1 -- SPACE 50 --

47 WP GFI RECEPTACLE 20 A 1 0.18 -- -- -- -- 1 -- SPACE 48 --

-- 45 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 46 --

-- 43 SPACE -- 1 -- -- -- -- 0 -- -- -- 1 20 A ADH TEMP SERVICE 44 --

-- 41 SPACE -- 1 -- -- -- -- 0 -- -- -- -- -- -- 42 --

-- 39 SPACE -- 1 -- -- -- -- 0 -- -- -- -- -- -- 40 --

-- 37 SPACE -- 1 -- -- -- -- 0 -- -- -- 3 20 A SPARE 38 --

-- 35 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 36 --

-- 33 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 34 --

-- 31 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 32 --

-- 29 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 30 --

-- 27 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 28 --

-- 25 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 26 --

-- 23 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 24 --

-- 21 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 22 --

-- 19 SPACE -- 1 -- -- -- -- -- -- -- -- 1 -- SPACE 20 --

-- 17 -- -- -- -- -- -- 0 -- -- -- -- 1 -- SPACE 18 --

-- 15 -- -- -- -- -- -- 0 -- -- -- -- 1 -- SPACE 16 --

-- 13 SPARE 20 A 3 -- -- -- 0 -- -- -- -- 1 -- SPACE 14 --

-- 11 -- -- -- -- -- -- 0 -- -- -- -- 1 -- SPACE 12 --

-- 9 -- -- -- -- -- -- 0 -- -- -- -- 1 -- SPACE 10 --

-- 7 SPARE 20 A 3 -- -- -- 0 -- -- -- -- 1 -- SPACE 8 --

-- 5 -- -- -- -- -- -- 0 -- -- -- -- 1 -- SPACE 6 --

-- 3 -- -- -- -- -- -- 0 -- -- -- -- 1 -- SPACE 4 --

-- 1 SPARE 20 A 3 -- -- -- 0 -- -- -- -- 1 -- SPACE 2 --

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

ISC UNKNOWN 0.00 kA

SCCR: 65 kA

LOCATION: WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

EXISTING PANEL 116-L1-4

100% CD 03/30

53095

T

114 56

140140

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

ROOM 3

MAILROOM

MECHANICAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRIDOR

RECEPTION

SCHEDULING

CLEAN

UTILITY

WC

STOR.

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

DN

EXISTING SA REGISTER

EXISTING RA GRILLEEXISTING

1 1/4" SPRINKLER

2" STUBBED &

CAPPED SANITARY

3 4

TELECOM

ROOM

MECHANICAL GENERAL NOTES:

THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED

TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.

1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE

DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.

DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,

AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE

INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING

CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.

2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM

ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR

PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.

3. COORDINATE ALL WORK WITH ALL OTHER TRADES AND COR PRIOR TO INSTALLATION TO

PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE,

AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO

VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES

OR CONFLICTS TO THE ATTENTION OF THE COR AND THE ARCHITECT/ENGINEER BEFORE

PROCEEDING WITH FABRICATION OR EQUIPMENT ORDERS.

4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE

REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER

ACCESS. FINAL LOCATIONS TO BE ACCURATELY DESCRIBED IN AS-BUILTS.

5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO

COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST, TIME OR

EXPENSE TO OTHERS.

6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL

CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF

DESIGN.

7. REFER TO CONTRACT DOCUMENTS, TO INCLUDE BUT NOT LIMITED TO, THE

ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIO/VISUAL, AND

OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES,

OTHER THAN SPRINKLERS.

8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,

FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS

RESPONSIBLE FOR PATCHING TO THE SATISFACTION OF THE COR TO MATCH ORIGINAL

CONSTRUCTION, FIRE RATING, AND FINISH.

9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE

COR FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE

PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE COR OF THE REQUIRED ACCESS

PANELS PRIOR TO BIDDING.

10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING,

AND DUCTS PENETRATE, BOTH NEW AND EXISTING. PENETRATIONS THROUGH EXTERIOR

WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH WATERPROOFING MATERIALS

RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.

11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL,

PARTITION, FLOOR, AND ROOF ASSEMBLIES, BOTH NEW AND EXISTING. THIS IS ESSENTIAL

TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE

DESIRED NC LEVELS WITHIN ROOMS.

12. WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED

OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL

RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.

13. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT

MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND

REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,

PIPING, DUCTWORK, ETC.

14. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.

15. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR

STARTERS, SWITCHES, AND DISCONNECTS.

16. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL

EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.

17. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER

NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE

CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.

18. CONTRACTOR TO COORDINATE SCHEDULE OF ANY NOISE-PRODUCING WORK SCOPE WITH

COR NOT LESS THAN 10 DAYS PRIOR TO COMMENCING WORK.

19. ALL CARTS, EQUIPMENT, MATERIAL AND TOOLS AS WELL AS ALL TOOL BAGS/BOXES AND

LADDERS ARE TO BE LABELED, CLEARLY IDENTIFYING THE CONTRACTOR/SUBCONTRACTOR

NAME AND PROJECT.

20. STORAGE OF TOOLS, EQUIPMENT AND MATERIALS IS ONLY AUTHORIZED IN APPROVED

LOCATIONS.

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.M

R

.r v t

/2

/2

:5

:4

P

M

116-M101

FIRST FLOOR DEMOLITION -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

RDL JCL

16305

KEYNOTES 1/116-M101:

1. REMOVE EXISTING REGISTER AND CAP DUCT.

2. REMOVE EXISTING GRILLE AND CAP DUCT.

3. EXISTING FIRE SPRINKLER BRANCH LINE TO BE RE-ROUTED.

4. DEMO 2" STUBBED AND CAPPED SANITARY PIPE TO OUTSIDE

OF ROOM AND CAP.

5. REMOVE EXISTING THERMOSTAT.

1/4" = 1'-0"

FIRST FLOOR DEMOLITION - MECHANICAL - EXIST RM 111

FIELD VERIFICATION NOTES

1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT

THEIR BID. THE FOLLOWING ITEMS SHALL BE FIELD VERIFIED:

A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE OF

WORK, WHETHER EXPLICITLY SHOWN OR NOT.

B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.

C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.

D. SIZE AND LOCATION OF EXISTING THERMOSTATIC CONTROL DEVICES.

E. SIZE AND LOCATION OF EXISTING PLUMBING AND HYDRONIC PIPING.

2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS, AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO THEIR BID AND INCLUDE IN THEIR BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.

3. ANY DISCREPANCIES WHICH MAY AFFECT CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND

ARCHITECT FOR DIRECTION.

N

0 4' 8'2'

100% CD 03/30

24706

03/30/2022

T

SPEECH

THERAPY

TREATMENT

ROOM 1

TREATMENT

ROOM 2

ROOM 3

MAILROOM

MECHANICAL

LOW

VOLTAGE

ELECTRICAL

ELECTRICAL

CORRIDOR

RECEPTION

SCHEDULING

CLEAN

UTILITY

WC

STOR.

SOILED LINEN

CLEAN LINEN

RECYCLING

HALLWAY

DN

MECHANICAL GENERAL NOTES:

THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED

TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.

1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE

DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.

DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,

AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE

INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING

CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.

2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM

ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR

PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.

3. COORDINATE ALL WORK WITH ALL OTHER TRADES AND COR PRIOR TO INSTALLATION TO

PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE,

AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO

VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES

OR CONFLICTS TO THE ATTENTION OF THE COR AND THE ARCHITECT/ENGINEER BEFORE

PROCEEDING WITH FABRICATION OR EQUIPMENT ORDERS.

4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE

REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER

ACCESS. FINAL LOCATIONS TO BE ACCURATELY DESCRIBED IN AS-BUILTS.

5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO

COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST, TIME OR

EXPENSE TO OTHERS.

6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL

CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF

DESIGN.

7. REFER TO CONTRACT DOCUMENTS, TO INCLUDE BUT NOT LIMITED TO, THE

ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIO/VISUAL, AND

OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES,

OTHER THAN SPRINKLERS.

8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,

FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS

RESPONSIBLE FOR PATCHING TO THE SATISFACTION OF THE COR TO MATCH ORIGINAL

CONSTRUCTION, FIRE RATING, AND FINISH.

9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE

COR FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE

PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE COR OF THE REQUIRED ACCESS

PANELS PRIOR TO BIDDING.

10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING,

AND DUCTS PENETRATE, BOTH NEW AND EXISTING. PENETRATIONS THROUGH EXTERIOR

WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH WATERPROOFING MATERIALS

RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.

11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL,

PARTITION, FLOOR, AND ROOF ASSEMBLIES, BOTH NEW AND EXISTING. THIS IS ESSENTIAL

TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE

DESIRED NC LEVELS WITHIN ROOMS.

12. WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED

OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL

RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.

13. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT

MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND

REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,

PIPING, DUCTWORK, ETC.

14. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.

15. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR

STARTERS, SWITCHES, AND DISCONNECTS.

16. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL

EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.

17. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER

NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE

CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.

18. CONTRACTOR TO COORDINATE SCHEDULE OF ANY NOISE-PRODUCING WORK SCOPE WITH

COR NOT LESS THAN 10 DAYS PRIOR TO COMMENCING WORK.

19. ALL CARTS, EQUIPMENT, MATERIAL AND TOOLS AS WELL AS ALL TOOL BAGS/BOXES AND

LADDERS ARE TO BE LABELED, CLEARLY IDENTIFYING THE CONTRACTOR/SUBCONTRACTOR

NAME AND PROJECT.

20. STORAGE OF TOOLS, EQUIPMENT AND MATERIALS IS ONLY AUTHORIZED IN APPROVED

LOCATIONS.

REROUTE

EXISTING 1 1/4"

SPRINKLER LINE

PROPOSED RACK

LOCATIONS

AC-116-1

PAN CONDENSATE

CONDENSATE PIPE IN

TR ROOM

CU-116-1

TELECOM

ROOM

CP-116-1

MECHANICAL RENOVATION NOTES:

THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED

TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.

1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD

SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND

REPORT ANY CONFLICTS BEFORE PROCEEDING.

2. NOT ALL EXISTING DUCTWORK AND PIPING IS SHOWN. VERIFY EXISTING CONDITIONS

BEFORE STARTING WORK. NOTIFY COR AND ENGINEER OF ANY CONFLICTS WITH NEW

WORK.

3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR DUCTWORK AND PIPING BEFORE

FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD

CONDITIONS.

4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS/HER WORK

AND SHALL NOTIFY THE COR AND ENGINEER PRIOR TO BIDDING IF OTHER UTILITIES ARE

REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF

WORK.

5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF

ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS.

CONTRACTORS SHALL NOTIFY THE COR AND ENGINEER OF AFFECTED AREAS PRIOR TO

BIDDING.

6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF

CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL

CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO

BIDDING.

7. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH

NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL

EITHER ARRANGE NEW EQUIPMENT, PIPING, OR DUCTWORK IN SUCH A FASHION THAT IT

DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING SYSTEMS TO ALLOW

FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.

8. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING

CONSTRUCTION. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT

REMAIN ACTIVE.

9. OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY

REASON. MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL NEW

SYSTEMS ARE INSTALLED.

10. MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR

TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS AND

CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLY OR COMPLETELY

DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH MINIMUM OUTAGE.

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.M

R

.r v t

/2

/2

:5

:4

P

M

116-M201

FIRST FLOOR REMODEL -

MECHANICAL

EHRM INFRASTRUCTURE

UPGRADES

656-21-235

RDL JCL

16305

KEYNOTES 1/116-M201:

1. NEW SPLIT SYSTEM AC UNIT.

2. REROUTED FIRE SPRINKLER BRANCH LINE. FIELD

VERIFY REQUIREMENTS.

3. NEW FIRE SPRINKLER HEAD.

4. NEW THERMOSTAT.

5. ROUTE REFRIGERANT PIPING TO NEW AIR-COOLED

CONDENSING UNIT LOCATED AT WEST EXTERIOR OF

BUILDING. FIELD VERIFY ROUTING.

6. NEW AIR-COOLED CONDENSING UNIT. PROVIDE

CONCRETE PAD OR WALL STAND.

7. ROUTE 1" CONDENSATE LINE TO MOP SINK IN HAC

ROOM LOCATED APPROXIMATELY 30 FT EAST. FIELD

VERIFY ROUTING.

8. PROVIDE DRIP PAN FOR CONDENSATE LINE IN TR

ROOM. SEE DETAIL FOR REQUIREMENTS.

1/4" = 1'-0"

FIRST FLOOR - MECHANICAL - EXIST RM 111

FIELD VERIFICATION NOTES

1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY

AFFECT THEIR BID. THE FOLLOWING ITMES SHALL BE FIELD VERIFIED:

A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN

SCOPE OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.

B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.

C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.

D. SIZE AND LOCATION OF EXISTING THERMOSTATIC CONTROL DEVICES.

E. SIZE AND LOCATION OF EXISTING PLUMBING AND HYDRONIC PIPING.

2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS, AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO THEIR BID AND INCLUDE IN THEIR BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.

3. ANY DISCREPANCIES WHICH MAY AFFECT CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER

AND ARCHITECT FOR DIRECTION.

0 4' 8'2'

N

100% CD 03/30

24706

03/30/2022

116-GI000 - BUILDING 116 COVER SHEET & SHEET INDEX
116-GI111 - FIRST FLOOR - INFECTION CONTROL & PHASING PLAN
116-AS110 - FIRST FLOOR PLANS
116-TD110 - FIRST FLOOR PLAN - TELECOM - DEMOLITION
116-TN110 - FIRST FLOOR PLAN - TELECOMMUNICATIONS
116-TN210 - FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE
116-TN400 - ENLARGED PLANS - TELECOMMUNICATIONS
116-E201 - FIRST FLOOR - ELECTRICAL
116-E300 - ELECTRICAL ENLARGED PLANS
116-M101 - FIRST FLOOR DEMOLITION - MECHANICAL
116-M201 - FIRST FLOOR REMODEL - MECHANICAL