Atch 10 - BLDG 4.pdf

PDF 15 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
Solicitation number
36C77622B0035
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document provides details for a federal contract solicitation to upgrade infrastructure at the St. Cloud Veterans Affairs Health Care System facility. The solicitation seeks a contractor to provide labor, materials, tools and equipment for electrical, bonding, UPS, building management system interfaces, access security, HVAC assessments and upgrades, data center/server room physical security upgrades, fiber infrastructure installation and upgrades both within and between buildings, and hazardous materials abatement. The work must be completed according to the specifications and contract drawings. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation number is 36C77622B0035 and is titled "Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud."

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud, newest first.
File Type Posted
Technical Questions - LATE - St. Cloud 8-10-22.pdf PDF
01-M204 - ROOF REMODEL -MECHANICAL.pdf PDF
Specifications Addendum Information.pdf PDF
Drawings Addendum Information.pdf PDF
Atch 1 - Specifications Volume 1 addendum.pdf PDF
Atch 11 - BLDG 5 addendum.pdf PDF
Atch 17 - BLDG 11 addendum.pdf PDF
Atch 18 - BLDG 14 addendum.pdf PDF
Atch 28 - BLDG 108 addendum.pdf PDF
Atch 33 - BLDG 116 addendum.pdf PDF
Atch 5 - General 2 of 2 addendum.pdf PDF
Atch 14 - BLDG 8 addendum.pdf PDF
Atch 15 - BLDG 9 addendum.pdf PDF
Atch 20 - BLDG 29 addendum.pdf PDF
Atch 22 - BLDG 49 addendum.pdf PDF
Atch 24 - BLDG 51 addendum.pdf PDF
Atch 25 - BLDG 54 and 69 addendum.pdf PDF
Atch 32 - BLDG 115 addendum.pdf PDF
OIT Design Requirements - St. Cloud - Backbone Cabling.zip ZIP file
Atch 10 - BLDG 4 addendum.pdf PDF
Atch 21 - BLDG 48 addendum.pdf PDF
Site Visit Sign-in Sheets - 6-28-22 - 6-30-22.pdf PDF
36C77622B0035 0001.pdf PDF
Atch 4 - General 1 of 2.pdf PDF
Atch 5 - General 2 of 2.pdf PDF
Atch 8 - BLDG 2.pdf PDF
Atch 23 - BLDG 50.pdf PDF
Atch 24 - BLDG 51.pdf PDF
Atch 27 - BLDG 96.pdf PDF
Atch 31 - BLDG 112.pdf PDF
Atch 34 - BLDG 118.pdf PDF
Atch 1 - Specifications Volume 1.pdf PDF
Atch 7 - BLDG 1 - 2 of 2.pdf PDF
Atch 12 - BLDG 6.pdf PDF
Atch 15 - BLDG 9.pdf PDF
Atch 18 - BLDG 14.pdf PDF
Atch 21 - BLDG 48.pdf PDF
Atch 25 - BLDG 54 and 69.pdf PDF
Atch 26 - BLDG 95 and 88.pdf PDF
Atch 28 - BLDG 108.pdf PDF
Atch 30 - BLDG 111.pdf PDF
Atch 32 - BLDG 115.pdf PDF
Atch 36 - Parking Structure.pdf PDF
Atch 40 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 43 - Site Visit Instructions.pdf PDF
Atch 20 - BLDG 29.pdf PDF
36C77622B0035 - 6-9-22.pdf PDF
Atch 6 - BLDG 1 - 1 of 2.pdf PDF
Atch 16 - BLDG 10.pdf PDF
Atch 19 - BLDG 28.pdf PDF
Show all 50

Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING FIBER - INSIDE

VFY EXIST

EXISTING FIBER - OUTSIDE

VFY EXIST

FIBER ROUTE - INSIDE

SEE TELECOM

FIBER ROUTE - OUTSIDE

SEE CIVIL

BUILDING OUTLINE

VFY EXIST

CORRIDOR OUTLINE

VFY EXIST

LEGEND

TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST

44TH AVE.

TRAIL 1

TRAIL 2

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2)

15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

GRAVEL

GRAVEL

GRAVEL

EXISTING

ROAD

CHAIN LINK FENCE

CHAIN LINK FENCE

16' GATE

GRAVEL

ELECTRICAL

SUBSTATION

G E N E R A T O R

FUEL LINES

CONDU ITS TO TU NNEL

M V

D U

C T

B A

N K

1 1 2 W

PHARMACY ADDITION

11 2 E

G E N E R A T O R

B

CORRIDOR LINK

A

C T

TR

A

IL

ER

174 s .f.

256 s .f.

185 s .f.

149 s ..f.

155 s .f.

104 s .f.

70 s. .f .

72 s .f.

110 s .f.

276 s .f.

112 s .f.

99 s .f.

57 s .f.

146 s .f.

434 s .f.

R A

MP

U P

1:

M A X

R A

MP

U P

1:

M A X

RA

M P

UP

1:2 0 M

AX

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2) 15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

.3

TRANSFORMER

BUILD ING

#91

5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN

O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW

C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D

P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S

R EC O M M EN D ATIO N S

N EW G AS SU P P LY M AIN

IN TO B U ILD IN G

SP AR E

P H O N E LIN E

EXTEN D S TO

E XISTIN G

P H O N E IN

B O ILER R O O M

P ER P LAN .

SP AR E

P H O N E

LIN E TO

M ETER

TU N N EL

E XTEN D S

A D D ITIO N AL

2'- 0" U N D ER

B U ILD IN G

FUEL LINE

VENT LINE

1,000 GAL.

UNDERGROUND

DIESEL FUEL

TANK

1,000/5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

S 1

LIG H T

N EW G AS SU P P LY

(C O O R D IN ATE W ITH SU P P LIER )

12"D

10"D

"D

TP TP

EXIST. BUILDING

EXIST.

BUS STOP

CC

L O

O P

16"

20"

12"

3"

8"

DN

0.

0’

BIRDCAGE

B

IR

D C

A G

E

NSP ELECTRICAL

FOR HWY DEPT

T101

I.T.

CHILLER

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

VESTIBULE

DN

DN

DN

FD

DN

F B

F

B

F B

F

B

F B

F

B

SOUTH

VESTIBULE

PASS

THROUGH

LINK TO

BUILDI NG 51

6 3. 32 56

1 13 5. 35 78

PARKING

NO

PARKING

93 49

37 6

109 5

1A

S M

O K

E B

L D

G

SMOKE

BLDG

SMOKE

BLDG

S M

O K

E B

L D

G

SMOKE

BLDG

M.H.

STOR.

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

STOR.

BIO-

HAZ.

SAUK RIVER

GP

HOLDING POND4

WEST EAST

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

OWNER AND

CONSULTANTS:

CONTACT:

ADDRESS:

MIKE ENGMARK

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

NAME:

ADDRESS:

CONTACT:

ADVANCED STRUCTURAL TECHNOLOGIES

7301 OHMS LANE; SUITE 215

EDINA, MN 55439

ZACHARY CRAIG

PHONE:

NAME:

ADDRESS:

CONTACT:

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

PHONE: 402-991-5520

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

IAN WEBER

763-412-4000

ARCHITECT:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

EDWARD MARKFORT

763-412-4000

952-854-9302

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

402-991-5520

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

COVER

DATE:

APPROVED: APPROVED: PROJECTS SECTION MANAGER

APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:

APPROVED: SAFETY MANAGER

APPROVED: CHIEF OF POLICE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE: APPROVED: EMS MANAGER

APPROVED: M/O MANAGER

DATE:

DATE:

DATE:DATE:

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: PROJECT COR DATE:

APPROVED: INFECTION CONTROL NURSE DATE:

APPROVED: SERVICE LINE DIRECTOR

APPROVED: GEMS COORDINATOR DATE:

DATE:

APPROVED: NURSE EXECUTIVE

APPROVED: CHIEF OF STAFF DATE:

APPROVED: DIRECTOR FMS

APPROVED: ASSOCIATE DIRECTOR

DATE:

DATE:

DATE:

DATE:APPROVED: DATE:

APPROVED: DATE:

APPROVED: DATE:

Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System

N

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

VICINITY MAP:

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHONE: 320-252-1670

CIVIL ENGINEER:

VA COR:

TELECOMMUNICATIONS ENGINEER:

CONTACT:

ADDRESS:

JONATHAN WEST

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

PHONE: 504-250-2699

PROGRAM MANAGER:

EMAIL: Jonathan.West@vciint.com

STRUCTURAL ENGINEER:

MECH/ELEC/PLUMB/FIRE ENGINEER:

C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :1

P

M

4-GI000

BUILDING 4 COVER SHEET &

SHEET INDEX

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM, BW

16305

BUILDING 4 - INFRASTRUCTURE UPGRADES

03/30/2022

0APPROX 150' 300'75'

SHEET INDEX - BUILDING 4

SHEET NO. SHEET TITLE

4-TN300 ENLARGED PLANS - TELECOMMUNICATIONS - DEMO

4-TN400 ENLARGED PLANS - TELECOMMUNICATIONS

4-TN401 ENLARGED PLANS - TELECOMMUNICATIONS

4-TN402 ENLARGED PLANS - TELECOMMUNICATIONS

4-TN403 ENLARGED PLANS - TELECOMMUNICATIONS

4-TN500 ONE-LINE DIAGRAM

4-TN501 PANEL SCHEDULES

04-E200 BASEMENT FLOOR PLAN - ELECTRICAL - EAST

04-E201 FIRST FLOOR PLAN - ELECTRICAL - EAST

04-E202 SECOND FLOOR PLAN - ELECTRICAL - EAST

04-E300 ELECTRICAL ENLARGED PLANS

04-E400 ELECTRICAL ONE-LINE DIAGRAMS

04-E500 ELECTRICAL SCHEDULES

04-M100B BASEMENT DEMOLITION - MECHANICAL - AREA B

04-M101B FIRST FLOOR DEMOLITION - MECHANICAL - AREA B

04-M200B BASEMENT FLOOR - MECHANICAL - AREA B

04-M201 FIRST FLOOR - MECHANICAL

04-M600 MECHANICAL SCHEDULES

SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION

SHEET INDEX - BUILDING 4

SHEET NO. SHEET TITLE

4-GI000 BUILDING 4 COVER SHEET & SHEET INDEX

4-GI100 BASEMENT LIFE SAFETY PLAN

4-GI101 BASEMENT FLOOR - INFECTION CONTROL & PHASING PLAN

4-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN

4-GI121 SECOND FLOOR - INFECTION CONTROL & PHASING PLAN

4-HA-1A REFERENCE - BASEMENT FLOOR ASBESTOS RE-SURVEY

4-HA-2A REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY

4-HA-3A REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY

4-AS100 BASEMENT FLOOR - OVERALL PLANS

4-AS110 FIRST FLOOR - OVERALL PLANS

4-AS120 SECOND FLOOR - OVERALL PLANS

4-AS400 LARGE SCALE PLANS

4-TD100 BASEMENT FLOOR PLAN - TELECOM - DEMOLITION

4-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION

4-TD120 SECOND FLOOR PLAN - TELECOM - DEMOLITION

4-TN100 BASEMENT FLOOR PLAN - TELECOMMUNICATIONS

4-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS

4-TN120 SECOND FLOOR PLAN - TELECOMMUNICATIONS

4-TN200 BASEMENT FLOOR PLAN - TELECOM - CABLE DISTANCE

4-TN210 FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

4-TN220 SECOND FLOOR PLAN - TELECOM - CABLE DISTANCE

1" = 50'-0"

KEY PLAN

ROOM SCHEDULE

NO. NAME C

A

B

LI

N G

P A

T C

H P

A N

E L

F

IB

E R

P O

W E

R

B O

N D

IN

G

U P

S

D E

D

IC

A T

E D

C O

O

LI

N G

T E

M P

E R

A T

U R

E

H U

M

ID

IT

Y

R A

C K

S E

N S

O R

S P

A C

E

AREA

WIDTH

(FT)

LENGTH

(FT)

HT TO

CLG

STRUCT REMARKS

BASEMENT

044 TELECOM ROOM X X X X X X X 64 SF 7.0 10.0 10.00 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM

ROOM STANDARDS. SEE TELECOM DRAWINGS

052 REDUNDANT DEMARC 111 SF 11.0 10.1 9.58 SEE TELECOM DRAWINGS

053 REDUNDANT DATA

CENTER UPS

X 278 SF 27.6 10.1 9.58 SEE TELECOM DRAWINGS

FIRST FLOOR

123C TELECOM ROOM X X X X X X X X X 168 SF 11.5 14.6 10.67 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM

ROOM STANDARDS. SEE TELECOM DRAWINGS

185 DATA CENTER 1252 SF 22.8 53.0 EXISTING DATA CENTER

SECOND FLOOR

222A TELECOM ROOM X X X X X X X X 113 SF 7.7 15.0 10.67 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM

ROOM STANDARDS. SEE TELECOM DRAWINGS

HAZARDOUS MATERIAL SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

QUESTIONABLE HAZARDOUS

ELEMENT POSSIBLE ABATEMENT ACTION

BASEMENT 044 TELECOM ROOM NONE. SEE 4-HA-1A NONE. ACM TO REMAIN UNDISTURBED

BASEMENT 052 REDUNDANT DEMARC NONE NONE

BASEMENT 053 REDUNDANT DATA

CENTER UPS

NONE NONE

FIRST FLOOR 123C TELECOM ROOM ACM. SEE 4-HA-2A. VERIFY CEILING

TILE

CONFIRM WITH COR. CONDUCT HAZARDOUS MATERIAL SURVEY. REMOVE HAZARDOUS MATERIAL UNDER FULL

CONTAINMENT

FIRST FLOOR 185 DATA CENTER NONE NONE

SECOND FLOOR 222A TELECOM ROOM SEE 4-HA-3A.REVIEW PAINTED WALL

BASEBOARD FOR LEAD BASED

PAINT

CONFIRM WITH COR. FLOOR FINISH ABATEMENT COMPLETE UNDER SEPARATE CONTRACT.

HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT

DISTURB QUESTIONABLE HAZARDOUS MATERIAL.

OPENING SCHEDULE

VA Building Number

ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION

H D

W G

R O

U P

F

IR

E L

A B

E L

(M

IN

G A

S K

E T

E

LE

C T

R

IC

A L

S L

A B

E L

COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT

PANEL

TYPE

2ND

PANEL

TYPE

PANEL

GLAZING FRAME TYPE

FRAME

GLAZING

4 REDUNDANT DEMARC 052 3'-0" 7'-0" HM-F NONE HMS-1 NONE HW-3.2A.1 45 Y Y Y

4 REDUNDANT DATA CENTER UPS 053 6'-0" 7'-0" HM-F HM-F NONE HMS-1 NONE HW-11.2 45 Y Y Y

4 TELECOM ROOM 123C 3'-0" 7'-0" WD-F NONE HMS-1 NONE HW-3.2B 45 Y Y Y

LEAK PREVENTION / DIVERTER SCHEDULE

LEVEL

ROOM

NO. ROOM NAME OVERHEAD LEAK DIVERTER AND DRAIN PIPING LEAK PREVENTION BARRIER WATERPROOFING

BASEMENT 044 TELECOM ROOM YES

BASEMENT 052 REDUNDANT DEMARC

BASEMENT 053 REDUNDANT DATA

CENTER UPS

FIRST FLOOR 123C TELECOM ROOM MASONRY INT: WEST

FIRST FLOOR 185 DATA CENTER

SECOND FLOOR 222A TELECOM ROOM

SEE GENERAL NOTES SHEET FOR DETAIL. MWP = MEMBRANE WATERPROOFING. MASONRY = FLUID-APPLIED WATERPROOFING. INT = INTERIOR. EXT = EXTERIOR

ICRA PHASE CONSTRUCTION ROOM SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

CAI BLDG NAME /

FUNCTION

CONSTRUCTION

PROJECT ACTIVITY

INFECTION CONTROL

RISK GROUP

CONTROL

PROCEDURE CLASS SECTION

CONSTRUCTION ZONE /

OCCUPIED CONSTR

DAY /

NIGHT

BASEMENT 044 TELECOM ROOM ADMINISTRATIVE /

DIETETICS

TYPE C GROUP 1 CLASS II CENTER OCCUPIED CONSTRUCTION NIGHT

BASEMENT 052 REDUNDANT DEMARC ADMINISTRATIVE /

DIETETICS

TYPE C GROUP 1 CLASS II CENTER ZONE4A NIGHT

BASEMENT 053 REDUNDANT DATA

CENTER UPS

ADMINISTRATIVE /

DIETETICS

TYPE C GROUP 1 CLASS II CENTER ZONE4A NIGHT

FIRST FLOOR 123C TELECOM ROOM ADMINISTRATIVE /

DIETETICS

TYPE C GROUP 3 CLASS III/IV CENTER ZONE4B NIGHT

FIRST FLOOR 185 DATA CENTER ADMINISTRATIVE /

DIETETICS

GROUP 1 CENTER OCCUPIED CONSTRUCTION NIGHT

SECOND FLOOR 222A TELECOM ROOM ADMINISTRATIVE /

DIETETICS

TYPE C GROUP 1 CLASS II CENTER OCCUPIED CONSTRUCTION NIGHT

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

0’

04-M200B BASEMENT FLOOR - MECHANICAL - AREA B

04-M201B FIRST FLOOR - MECHANICAL - AREA B

04-M600 MECHANICAL SCHEDULES

SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION

CW1

HW1

R

R

R

R

R

R

R

R

R

R R

R

R

DIETETIC

STORAGE

ELECTRICAL

21A

MECHANICAL

21 MECHANICAL

UNIFINISHED SPACE

HAC

SPS ADMIN/

VENDOR DROP

SPS

CHIEF

OFFICE

26A

CORRIDOR

CON

CORRIDOR

C0S

STAIR

UNFINISHED

SPACE

19B

STORAGE

REFRIGERATION

EQUIPMENT

23A

STAIR

ELEV

E01

HAC

SUPPLY

FRIDGE

13A

CORRIDOR

SPS MECHANICAL

STERILIZATION

PREP ASSEMBLY

SCOPE

PROCESSING

CRAWL

SPACE

SERVICE TUNNEL

DIRTY

ANTE

MECHANICAL

WOMEN'S

LOCKER ROOM

STAIR

MEN'S

LOKER ROOM

WOMEN'S DECON

LOCKER ROOM

5A

MEN'S DECON

LOCKER ROOM

4A

EXISTING

ELEVATOR

EQUIPMENT

ROOM

DIRTY

LOBBY

DIRTY ELEVATOR

MORGUE

OXYGEN

STORAGE

2A

EQUIP

CLOSET

ELEC

PANELS

CORRIDOR

STAFF LOUNGE

CLEAN ALCOVE

IT

DIRTY

ALCOVE

DIRTY

CORRIDOR

HAC

50 SOAP

DISPENSER

SYSTEM CLOSET

RO

SYSTEM

STORAGE

SCOPE

DECON

CLEAN

ANTE

CORRIDOR

C0W

DECON

WOKR AREA

STAIRS

LOW VOLTAGE

CRAWL SPACE

CRAWL SPACE

TUNNEL TO BUILDING 6

MORGUE

REFRIGERATOR

MECHANICAL

ALCOVE

19C

CORRIDOR

ALCOVE

25A

CORRIDOR

19A

STORAGE

25B

LOW VOLTAGE

2,300 SF

MECHANICAL

UP

STAIRS

UTILITY

ROOM

MECH.

DEMARK

MECH.

UP

-A

S

-A

S

7'-0" 4'-0"20'-7 1/4", V.I.F. 7'-0"

REDUNDANT

DATA

CENTER

UPS

REDUNDANT

DEMARC

4-AS400

TRAVEL DISTANCE

69'-3" TRAVEL DISTANCE

97'-9"

TELECOM

ROOM

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :1

P

M

4-GI100

BASEMENT LIFE SAFETY PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1/8" = 1'-0"

BASEMENT FLOOR - LIFE SAFTEY PLAN

R

R

R

R

R

R

R

R

R

R R

R

R

DIETETIC

STORAGE

ELECTRICAL

21A

MECHANICAL

21 MECHANICAL

UNIFINISHED SPACE

HAC

SPS ADMIN/

VENDOR DROP

SPS

CHIEF

OFFICE

26A

CORRIDOR

CON

CORRIDOR

C0S

STAIR

UNFINISHED

SPACE

19B

STORAGE

REFRIGERATION

EQUIPMENT

23A

STAIR

ELEV

E01

HAC

SUPPLY

FRIDGE

13A

CORRIDOR

SPS MECHANICAL

STERILIZATION

PREP ASSEMBLY

SCOPE

PROCESSING

CRAWL

SPACE

SERVICE TUNNEL

DIRTY

ANTE

MECHANICAL

WOMEN'S

LOCKER ROOM

STAIR

MEN'S

LOKER ROOM

WOMEN'S DECON

LOCKER ROOM

5A

MEN'S DECON

LOCKER ROOM

4A

EXISTING

ELEVATOR

EQUIPMENT

ROOM

DIRTY

LOBBY

DIRTY ELEVATOR

MORGUE

OXYGEN

STORAGE

2A

EQUIP

CLOSET

ELEC

PANELS

CORRIDOR

STAFF LOUNGE

CLEAN ALCOVE

IT

DIRTY

ALCOVE

DIRTY

CORRIDOR

HAC

50 SOAP

DISPENSER

SYSTEM CLOSET

RO

SYSTEM

STORAGE

SCOPE

DECON

CLEAN

ANTE

CORRIDOR

C0W

DECON

WOKR AREA

STAIRS

LOW VOLTAGE

CRAWL SPACE

CRAWL SPACE

TUNNEL TO BUILDING 6

MORGUE

REFRIGERATOR

MECHANICAL

ALCOVE

19C

CORRIDOR

ALCOVE

25A

CORRIDOR

19A

STORAGE

25B

LOW VOLTAGE

2,300 SF

MECHANICAL

UP

STAIRS

UTILITY

ROOM

MECH.

DEMARK

MECH.

UP

CRAWL SPACE

WEST EAST

REDUNDANT

DATA

CENTER

UPS

REDUNDANT

DEMARC

TELECOM

ROOM

-G

I1

ZONE 4A

CONSTRUCTION / ICRA BARRIER

-G

I1

INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :2

P

M

4-GI101

BASEMENT FLOOR -

INFECTION CONTROL &

PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1" = 50'-0"

KEY PLAN

N

0 8' 16'4'

N

0 8' 16'4'

N

1/8" = 1'-0"

BASEMENT FLOOR - CONST BARRIER PLAN EAST

1/8" = 1'-0"

BASEMENT FLOOR - CONST BARRIER PLAN WEST

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

BASEMENT 044 TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

BASEMENT 052 REDUNDANT DEMARC ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

BASEMENT 053 REDUNDANT DATA

CENTER UPS

ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

FIRST FLOOR 123C TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 3 CLASS III/IV

FIRST FLOOR 185 DATA CENTER ADMINISTRATIVE / DIETETICS GROUP 1

SECOND FLOOR 222A TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

SEQUENCE OF EVENTS - ZONE 4A

• SELECTIVE UPGRADE TO EXISTING INFORMATION TECHNOLOGY TO ENABLE

BUILDING TOTAL UPGRADE PROCESS

• INITIAL ICRA AND ILSM

• CONSTRUCTION OF BARRIER IN ONE NIGHT SHIFT. BARRIER INCLUDES DOORS

AND PARTITION TO BECOME PERMANENT CONSTRUCTION OF ROOM

• HAZARDOUS MATERIAL ABATEMENT AS INDICATED

• DEMOLITION TO FACILITATE PLAN

• CONSTRUCT ROOMS AS DIRECTED, SEE ASSOCIATED DRAWINGS FROM

STRUCTURAL, ELECTRICAL, MECHANICAL, TELECOM, AND FINISHES

• INSTALL TEMPORARY PROTECTION AND CONDUCT SELECTIVE DEMOLITION TO

ENABLE UPGRADES

• INSTALL COMMON CABLE INFRASTRUCTURE

• CONSTRUCT COMMUNICATION BACKBONE

• INSTALL CAT 6A

• DECOMMISSION EXISTING NON-EHRM INFORMATION TECHNOLOGY ROOMS

SUGGESTED SEQUENCE. FINAL INSTALLATION SEQUENCE TO BE MADE AT A LATER DATE.

S

OFFICE

124H

OFFICE

124G

OFFICE

124F

OFFICE

124E

OFFICE

124D

OFFICE

124C

OFFICE

124B

ALCOVE

124Q

(EXISTING)

OFFICE

(EXISTING)

OFFICE

(EXISTING)

TOILET

124A

CORRIDOR

C1SW

CORRIDOR

124S

CORRIDOR

(EXISTING)

ENTRY

123A

LOBBY

120N

ELEV

E03

MECH

120M

B

RECEPTION

124L

ENTRY

124M

CONSULTATION

124K

CONSULTATION

124J

CONFERENCE

124I

(EXISTING)

OFFICE

126A

(EXISTING)

TOILET

124A

(EXISTING)

STORAGE

(EXISTING)

CHIEF OFFICE

126MECHANICAL

124R

WAITING

124O

ALCOVE

124P

CORRIDOR

CORRIDOR

ENTRY

124N

C

F

WEST EAST

123C

TELECOM

ROOM

-G

I1

ZONE 4B

CONSTRUCTION / ICRA BARRIER

-G

I1

1 INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :2

P

M

4-GI111

FIRST FLOOR - INFECTION

CONTROL & PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

N

0 8' 16'4'

N

0 8' 16'4'

1" = 50'-0"

KEY PLAN

1/8" = 1'-0"

FIRST FLOOR - CONST BARRIER PLAN EAST

1/8" = 1'-0"

FIRST FLOOR - CONST BARRIER PLAN WEST

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

BASEMENT 044 TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

BASEMENT 052 REDUNDANT DEMARC ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

BASEMENT 053 REDUNDANT DATA

CENTER UPS

ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

FIRST FLOOR 123C TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 3 CLASS III/IV

FIRST FLOOR 185 DATA CENTER ADMINISTRATIVE / DIETETICS GROUP 1

SECOND FLOOR 222A TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

SEQUENCE OF EVENTS - ZONE 4B

• SELECTIVE UPGRADE TO EXISTING INFORMATION TECHNOLOGY TO ENABLE

BUILDING TOTAL UPGRADE PROCESS

• INITIAL ICRA AND ILSM

• CONSTRUCTION OF BARRIER IN ONE NIGHT SHIFT. BARRIER INCLUDES DOOR

AND PARTITION TO BECOME PERMANENT CONSTRUCTION OF ROOM

• HAZARDOUS MATERIAL ABATEMENT AS INDICATED

• DEMOLITION TO FACILITATE PLAN

• CONSTRUCT ROOMS AS DIRECTED, SEE ASSOCIATED DRAWINGS FROM

STRUCTURAL, ELECTRICAL, MECHANICAL, TELECOM, AND FINISHES

• INSTALL TEMPORARY PROTECTION AND CONDUCT SELECTIVE DEMOLITION TO

ENABLE UPGRADES

• INSTALL COMMON CABLE INFRASTRUCTURE

• CONSTRUCT COMMUNICATION BACKBONE

• INSTALL CAT 6A

• DECOMMISSION EXISTING NON-EHRM INFORMATION TECHNOLOGY ROOMS

SUGGESTED SEQUENCE. FINAL INSTALLATION SEQUENCE TO BE MADE AT A LATER DATE.

RAMP UP

STAIR ELEV

PATIENT

SAFETY

FISCAL

PORCH

ROOF

ACCOUNTING

ELEV

LOBBY

ELEV

FISCAL

OFFICER

219 EMPLOYMENT

INFORMATION

223B

COPY

FISCAL

OFFICE

223A

CONF. ROOM

COPY &

COMP. ROOM

CHIEF OF

STAFF

CREDENTIAL.

AO

OFFICE

NURSE

EXECUTIVE

SECRETARIES

250 251

AO

DIRECTOR

COMPLIANCE

QM

ADMIN

ADPAC

ASST. HOSP.

DIRECTOR

SECRETARIES

HOSPITAL

DIRECTOR

245 TOILET

RESOURCES

VENTILATING &

EQUIPMENT

STAIR

ELEVATOR PENTHOUSE

QUALITY

MANAGEMENT

QUALITY

MANAGEMENT

HAC

PHONE

222A

CLOSET

231A

CLOSET

233A

CLOSET

232A

CLOSET

246A

CORRIDOR

C2WC

CORRIDOR

C2EC

CORRIDOR

C2E

CORRIDOR

C2C

CORRIDOR

C2E

ATTIC

ACCESS

HR

SECRETARY

FISCAL

FISCAL

OFFICE

SUPERVISOR

H.R.

FEMALE

STAIR

HUMAN

RESOURCES

HUMAN

RESOURCES

TRAVEL

HUMAN

RESOURCES

HUMAN

RESOURCES

MANAGEMENT

SPECIALIST

HUMAN

RESOURCES

HUMAN

RESOURCES

PAYROLL

HUMAN

RESOURCES

MALE

HUMAN

RESOURCES

CLOSET

203A

CLOSET

203B

CLOSET

205A

CLOSET

204A

CLOSET

209A

CLOSET

209B

CLOSET

210A

CLOSET

212A

CLOSET

212B

CLOSET

205A

HAC

213A

CLOSET

215A

CLOSET

218A

CORRIDOR

C2W

WEST EAST

222A

TELECOM

ROOM

-G

I1

-G

I1

INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :3

P

M

4-GI121

SECOND FLOOR - INFECTION

CONTROL & PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

N

0 8' 16'4'

N

0 8' 16'4'

1" = 50'-0"

KEY PLAN

1/8" = 1'-0"

SECOND LEVEL - CONST BARRIER PLAN EAST

1/8" = 1'-0"

SECOND LEVEL FLOOR PLAN

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

BASEMENT 044 TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

BASEMENT 052 REDUNDANT DEMARC ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

BASEMENT 053 REDUNDANT DATA

CENTER UPS

ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

FIRST FLOOR 123C TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 3 CLASS III/IV

FIRST FLOOR 185 DATA CENTER ADMINISTRATIVE / DIETETICS GROUP 1

SECOND FLOOR 222A TELECOM ROOM ADMINISTRATIVE / DIETETICS TYPE C GROUP 1 CLASS II

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

-ASBESTOS-CONTAINING FIRE DOOR

-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC

-ASBESTOS-CONTAINING WINDOW CAULK, GLAZING, AND WALL ADHESIVE ABOVE WINDOW

-ASBESTOS-CONTAINING WINDOW CAULK AND GLAZING

-ASBESTOS-CONTAMINATED SOIL

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

LEGEND

BUILDING #4 - BASEMENT FLOOR PLAN

-ASBESTOS-CONTAINING MASTIC UNDER CARPET

-ASBESTOS-CONTAINING WINDOW CAULK, GLAZING, AND WALL ADHESIVE ABOVE WINDOW

-ASBESTOS-CONTAINING WINDOW CAULK AND GLAZING

T S

-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)

-ASBESTOS-CONTAINING PIPE INSULATION (HORIZONTAL RISERS)

-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC

-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC UNDER CARPET

-ASBESTOS-CONTAINING WALL TILE MASTIC

-ASBESTOS-CONTAINING PIPE INSULATION (VERTICAL RISERS)

N

W E

BUILDING #4 - FIRST FLOOR PLAN

-ASBESTOS-CONTAINING MASTIC UNDER CARPET

-ASBESTOS-CONTAINING WINDOW CAULK AND GLAZING

-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC

-ASBESTOS-CONTAINING MASTIC UNDER 12" FLOOR TILE

-ASBESTOS-CONTAINING MASTIC UNDER CARPET AND FLOOR FILLER

-ASBESTOS-CONTAINING FLOOR TILE AND MASTIC UNDER CARPET

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

BUILDING #4 - SECOND FLOOR PLAN

R

R

R

R

R

R

R

R

R

R R

R

R

DIETETIC

STORAGE

ELECTRICAL

21A

MECHANICAL

21 MECHANICAL

UNIFINISHED SPACE

HAC

SPS ADMIN/

VENDOR DROP

SPS

CHIEF

OFFICE

26A

CORRIDOR

CON

CORRIDOR

C0S

STAIR

UNFINISHED

SPACE

19B

STORAGE

REFRIGERATION

EQUIPMENT

23A

STAIR

ELEV

E01

HAC

SUPPLY

FRIDGE

13A

CORRIDOR

SPS MECHANICAL

STERILIZATION

PREP ASSEMBLY

SCOPE

PROCESSING

CRAWL

SPACE

SERVICE TUNNEL

DIRTY

ANTE

MECHANICAL

WOMEN'S

LOCKER ROOM

STAIR

MEN'S

LOKER ROOM

WOMEN'S DECON

LOCKER ROOM

5A

MEN'S DECON

LOCKER ROOM

4A

EXISTING

ELEVATOR

EQUIPMENT

ROOM

DIRTY

LOBBY

DIRTY ELEVATOR

MORGUE

OXYGEN

STORAGE

2A

EQUIP

CLOSET

ELEC

PANELS

CORRIDOR

STAFF LOUNGE

CLEAN ALCOVE

IT

DIRTY

ALCOVE

DIRTY

CORRIDOR

HAC

50 SOAP

DISPENSER

SYSTEM CLOSET

RO

SYSTEM

STORAGE

SCOPE

DECON

CLEAN

ANTE

CORRIDOR

C0W

DECON

WOKR AREA

STAIRS

LOW VOLTAGE

CRAWL SPACE

CRAWL SPACE

TUNNEL TO BUILDING 6

MORGUE

REFRIGERATOR

MECHANICAL

ALCOVE

19C

CORRIDOR

ALCOVE

25A

CORRIDOR

19A

STORAGE

25B

LOW VOLTAGE

2,300 SF

MECHANICAL

UP

STAIRS

UTILITY

ROOM

MECH.

DEMARK

MECH.

UP

CRAWL SPACE

-A

S

7'-0" 4'-0"20'-7 1/4", V.I.F. 7'-0"

REDUNDANT

DATA

CENTER

UPS 052

REDUNDANT

DEMARC

4-AS400

7' -0

10'-0"

TELECOM

ROOM

27'-7 1/4" 11'-0"

'-1

/2

V

.I.

F

-A

S

WEST EAST

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :3

P

M

4-AS100

BASEMENT FLOOR - OVERALL

PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM, BW

16305

03/30/2022

1/8" = 1'-0"

BASEMENT FLOOR - OVERALL PLAN EAST

1/8" = 1'-0"

BASEMENT FLOOR - OVERALL PLAN WEST

N

0 8' 16'4'

N

0 8' 16'4' 1" = 50'-0"

KEY PLAN

N

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

RECEPTION

124L

ENTRY

124M

CONSULTATION

124K

CONSULTATION

124J

CONFERENCE

124I

(EXISTING)

OFFICE

126A

(EXISTING)

TOILET

124A

(EXISTING)

STORAGE

(EXISTING)

CHIEF OFFICE

126MECHANICAL

124R

WAITING

124O

ALCOVE

124P

CORRIDOR

CORRIDOR

ENTRY

124N

C

F

STAIR

WAITING

OFFICE

OFFICE

OFFICE 134

CONSULT

PATIENT

OFFICE

MECHANICAL

3'-6"

296 S.F.

7'-1 1_

3'-6"

120 S.F.

120 S.F.

105 S.F.

62. 0000

3'-4"

C o p ie r

8'-9 3_

3'-6"

4'-6 15__

580 S.F.

641 S.F.

S

UCF

FEC

FEC

FEC

R E

F

FEC

OFFICE

124H

OFFICE

124G

OFFICE

124F

OFFICE

124E

OFFICE

124D

OFFICE

124C

OFFICE

124B

ALCOVE

124Q

(EXISTING)

OFFICE

(EXISTING)

OFFICE

(EXISTING)

TOILET

124A

CORRIDOR

C1SW

CORRIDOR

124S

CORRIDOR

(EXISTING)

ENTRY

123A

LOBBY

120N

ELEV

E03

MECH

120M

C1S

CORRIDOR

KITCHEN

COOLER

DOCK

SPS /

LOGISTICS

91 SF

SOILED

HOLDING

95 SF

PROCEDURE

213 SF

CLEAN

STORAGE

42 SF

CLEAN

STORAGE

48 SF

EXAM 6

12O SF

EXAM 12

120 SF

EXAM 11

120 SFEXAM 5

120 SF

TLT

59 SF

TEAM

WORK AREA

500 SF

TEAM

WORK AREA

682 SF

EXAM 10

120 SF

EXAM 4

120 SF

EXAM 3

120 SF

EXAM 9

120 SF

EXAM 15

120 SF

EXAM 14

120 SF

EXAM 8

120 SF

EXAM 2

120 SF

EXAM 1

120 SF

EXAM 7

120 SF

MEDICATION

92 SF

STORAGE

48 SF

CLEAN

STORAGE

68 SF

TLT

59 SF

TLT

59 SF

HAC

54 SF

EXAM 13

120 SF

TLT

61 SF

WAITING

840 SF

(32 SEATS)

STAND UP

SCALE

STAND UP

SCALE

SELF

CHECK-IN

KIOSKS

131A

FRIDGE

131B

FRIDGE

C1W

CORRIDOR

100B

STORAGE

C1W

CORRIDOR

DOCK

B

STORAGE

MED. STO.

SOILED HOLD

LINEN

PROCEDURE

CLEAN

EXAM 4

EXAM 3

EXAM 2

EXAM 1

TOILET

165A

TOILET

164A

TOILET

172A

TOILET

171A

TOILET

170A

VENDING STO.

174A

VENDING/

BREAK ROOM

REFERRAL

OFFICE

CONFERENCE

STORAGE

HAC

ELEC

FAMILY

FAMILY

175MEETING ROOM

173A

WAITING

RECEPTION

NURSE WORK

CORRIDOR

C1

CORRIDOR

C2

CORRIDOR

C3

CORRIDOR

C4

ELECTRICAL

MECHANICAL

DATA ROOM

WORK ROOM

LOBBY

VESTIBULE

STORAGE

EXISTING

CORRIDOR

E

STAIRWELL

ELECT.

100A

UP

UP

UP

UP

-A

S

123C

TELECOM

ROOM

-A

S

'-9

53'-0"

11'-6"

'-7

/2

4-AS400

3C

WEST EAST

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :4

P

M

4-AS110

FIRST FLOOR - OVERALL

PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM, BW

16305

03/30/2022

N

0 8' 16'4'

N

0 8' 16'4'1/8" = 1'-0"

FIRST FLOOR - OVERALL PLAN WEST

1/8" = 1'-0"

FIRST FLOOR - OVERALL PLAN EAST

1" = 50'-0"

KEY PLAN

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

HR

SECRETARY

FISCAL

FISCAL

OFFICE

SUPERVISOR

H.R.

FEMALE

STAIR

HUMAN

RESOURCES

HUMAN

RESOURCES

TRAVEL

HUMAN

RESOURCES

HUMAN

RESOURCES

MANAGEMENT

SPECIALIST

HUMAN

RESOURCES

HUMAN

RESOURCES

PAYROLL

HUMAN

RESOURCES

MALE

HUMAN

RESOURCES

CLOSET

203A

CLOSET

203B

CLOSET

205A

CLOSET

204A

CLOSET

209A

CLOSET

209B

CLOSET

210A

CLOSET

212A

CLOSET

212B

CLOSET

205A

HAC

213A

CLOSET

215A

CLOSET

218A

CORRIDOR

C2W

RAMP UP

STAIR ELEV

PATIENT

SAFETY

FISCAL

PORCH

ROOF

ACCOUNTING

ELEV

LOBBY

ELEV

FISCAL

OFFICER

219 EMPLOYMENT

INFORMATION

223B

COPY

FISCAL

OFFICE

223A

CONF. ROOM

COPY &

COMP. ROOM

CHIEF OF

STAFF

CREDENTIAL.

AO

OFFICE

NURSE

EXECUTIVE

SECRETARIES

250 251

AO

DIRECTOR

COMPLIANCE

QM

ADMIN

ADPAC

ASST. HOSP.

DIRECTOR

SECRETARIES

HOSPITAL

DIRECTOR

245 TOILET

RESOURCES

VENTILATING &

EQUIPMENT

STAIR

ELEVATOR PENTHOUSE

QUALITY

MANAGEMENT

QUALITY

MANAGEMENT

HAC

PHONE

222A

CLOSET

231A

CLOSET

233A

CLOSET

232A

CLOSET

246A

CORRIDOR

C2WC

CORRIDOR

C2EC

CORRIDOR

C2E

CORRIDOR

C2C

CORRIDOR

C2E

ATTIC

ACCESS

-A

S

222A

TELECOM

ROOM

-A

S

7'-8"

4-AS400

WEST EAST

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :4

P

M

4-AS120

SECOND FLOOR - OVERALL

PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM, BW

16305

03/30/2022

N

0 8' 16'4'

N

0 8' 16'4'1/8" = 1'-0"

SECOND FLOOR - OVERALL PLAN WEST

1/8" = 1'-0"

SECOND FLOOR - OVERALL PLAN EAST

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

1" = 50'-0"

KEY PLAN

STAIR

STAIR

PHONE

222A

STAIR

DEMARK

MECH.

MECH.

123C

TELECOM

ROOM

3C

IN-03.01

B3b

4'-5" 2'-6" 4'-7"

123C

TELECOM

ROOM

TELECOM

ROOM

222A

TELECOM

ROOM

ACCOUNTING

IN-03.01

2' -6

5'

-8

3/

8"

222A

TELECOM

ROOM

TELECOM

ROOM

3'-10"

REDUNDANT

DATA

CENTER

UPS

REDUNDANT

DEMARC

B6bs

B6bs

IN-03.01

3'-10"

IN-03.01

TELECOM

ROOM

3'-3 89/128" 2'-6" 3'-4 39/128"

TELECOM

ROOM

REDUNDANT

DATA

CENTER

UPS

REDUNDANT

DEMARC

TELECOM

ROOM

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -4

-R E

M a rk fo rt

.r v t

/2

/2

:5 :5

P

M

4-AS400

LARGE SCALE PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM, BW

16305

03/30/2022

1/4" = 1'-0"1

ENLARGED FLOOR PLAN - RM123C

N

0 4' 8'2'

N

N

0 4' 8'2'

N

1/4" = 1'-0"

DEMOLITION PLAN - RM123C

1/4" = 1'-0"

REFLECTED CEILING PLAN - RM123C

N

0 4' 8'2'

1/4" = 1'-0"4

ENLARGED FLOOR PLAN - RM222A

1/4" = 1'-0"

DEMOLITION PLAN - RM222A

1/4" = 1'-0"

REFLECTED CEILING PLAN - RM222A

N

0 4' 8'2'

N

N

0 4' 8'2'

N

N

0 4' 8'2'

FL2

RC1 RC8

_REFLECTED CEILING PLAN KEYED NOTES

RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET

ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE

VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET

ROW OR SECTION.

RC2 OPEN TO STRUCTURAL FLOOR ABOVE

RC8 REMOVE SUSPENDED CEILING AS REQUIRED, OPEN TO STRUCTURAL

FLOOR ABOVE

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_FLOOR PLAN KEYED NOTES

FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”

TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH

HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT

FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT

OVER FIRE RATING STAMP.

FL2 DOOR, SIZE AS SCHEDULED, FIRE RESISTANT AS SCHEDULED

FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE

TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST

THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS

WITH FIRE CAULK.

FL4 PATCH TO MATCH FINISHES DISTURBED BY CONSTRUCTION TO MATCH

EXISTING; FLOOR AND WALL. CONTRACTOR TO PROVIDE LABOR AND

MATERIAL.

FL6 FINISH NEW PARTITIONS TO MATCH EXISTING PARTITIONS THIS AREA

FL11 FINISH NEW PORTION OF PARITITION WITH CT-1

FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.

FL22 LEAK PREVENTION BARRIER WATERPROOFING DETAIL AT EXISTING

PARTITION. SEE AS601.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_DEMOLITION PLAN KEYED NOTES

DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM

REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS

DE2 REMOVE AND SALVAGE DOOR. PREPARE OPENING FOR DOOR WITH

IMPROVED SECURITY. SEE FLOOR PLAN AND DOOR SCHEDULE

DE4 CAREFULLY REMOVE AND SALVAGE EXISTING ACT CEILING SYSTEM AS

REQUIRED FOR NEW CONSTRUCTION. SEE RCP

DE6 REMOVE PARTITION TO THE EXTENTS SHOWN

DE21 PREPARE FLOOR FOR FINISH AND RATED PARTITIONS, SEE FLOOR PLAN

DE24 REMOVE EXISTING WALL TILE.

DE25 REMOVE EXISTING KITCHEN FLOOR TILE AND ALL ASSOCIATED

SUBSTRATES TO THE EXTENTS SHOWN.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

DE1

RC1 RC2

FL11

DE1

DE1

DE1

DE1

DE1

FL1FL3

FL1

FL3

FL22

FL3

FL3

FL20 FL20

DE24

DE24

DE4

DE2

DE6

DE25

DE6

FL4

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

1/4" = 1'-0"7

ENLARGED FLOOR PLAN - RM 044, 052, 053

1/4" = 1'-0"

DEMOLITION PLAN - RM044

FL1 FL1

FL1

FL20

FL20FL1

N

0 4' 8'2'

FL3

N

0 4' 8'2'

FL3

FL3

FL3

FL3

FL3

FL6

1/4" = 1'-0"

REFLECTED CEILING PLAN - RM 044, 052, 053

RC1 RC2

RC1 RC2

DE24

DE6

RC1 RC2

DE1

DE1

DE1

N

0 4' 8'2'

FL3

FL3

FL3 FL20FL1

DE21 DE21

CRAWL SPACE

HW1

R

R

R

R

R

R

R

R

R R

R

R

DIETETIC

STORAGE

ELECTRICAL

21A

MECHANICAL

21 MECHANICAL

UNIFINISHED SPACE

HAC

SPS ADMIN/

VENDOR DROP

SPS

CHIEF

OFFICE

26A

CORRIDOR

CON

CORRIDOR

C0S

STAIR

UNFINISHED

SPACE

19B

STORAGE

REFRIGERATION

EQUIPMENT

23A

STAIR

ELEV

E01

HAC

SUPPLY

FRIDGE

13A

CORRIDOR

SPS MECHANICAL

STERILIZATION

PREP ASSEMBLY

SCOPE

PROCESSING

CRAWL

SPACE

SERVICE TUNNEL

DIRTY

ANTE

MECHANICAL

WOMEN'S

LOCKER ROOM

STAIR

MEN'S

LOKER ROOM

WOMEN'S DECON

LOCKER ROOM

5A

MEN'S DECON

LOCKER ROOM

4A

EXISTING

ELEVATOR

EQUIPMENT

ROOM

DIRTY

LOBBY

DIRTY ELEVATOR

MORGUE

OXYGEN

STORAGE

2A

EQUIP

CLOSET

ELEC

PANELS

CORRIDOR

STAFF LOUNGE

CLEAN ALCOVE

IT

DIRTY

ALCOVE

DIRTY

CORRIDOR

HAC

50 SOAP

DISPENSER

SYSTEM CLOSET

RO

SYSTEM

STORAGE

SCOPE

DECON

CLEAN

ANTE

CORRIDOR

C0W

DECON

WOKR AREA

STAIRS

LOW VOLTAGE

CRAWL SPACE

CRAWL SPACE

TUNNEL TO BUILDING 6

MORGUE

REFRIGERATOR

MECHANICAL

ALCOVE

19C

CORRIDOR

ALCOVE

25A

CORRIDOR

19A

STORAGE

25B

LOW VOLTAGE

2,300 SF

MECHANICAL

UP

STAIRS

UTILITY

ROOM

MECH.

DEMARK

MECH.

UP

E

E

E E

E

FB

FB

4-TN300

LIMITS OF DATA CABLING DEMOLITION

12"x4"

12"x4"

24"x4"

"x

4"

"x

4"

8" x4

8"x4"

8" x4

8"x4"8"x4"

8" x4

8" x4

8"x4"

8" x4

E E

E

EE

E

E

EE

E

E

E 24"x4"

"x

4"

12"x4"12"x4"12"x4"12"x4"

8" x4

12"x4"

E

EE

E

E E

E E

E

E

WEST EAST

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

4-TD100

BASEMENT FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

N

0 8' 16'4'1/8" = 1'-0"

BASEMENT FLOOR PLAN - TELECOM - DEMOLITION - WEST

1/8" = 1'-0"

BASEMENT FLOOR PLAN - TELECOM - DEMOLITION - EAST

N

0 8' 16'4'

1" = 50'-0"

KEY PLAN

SHEET NOTES:

1. RETAIN DATA CABLE: EXISTING DATA CABLE THROUGHOUT THIS AREA IS SUFFICIENT TO REMAIN. NEW

CABLING NOT REQUIRED. RETAIN EXISTING CABLING IN SERVICE.

UCF

FEC

FEC

FEC

R E

F

FEC

OFFICE

124H

OFFICE

124G

OFFICE

124F

OFFICE

124E

OFFICE

124D

OFFICE

124C

OFFICE

124B

ALCOVE

124Q

(EXISTING)

OFFICE

(EXISTING)

OFFICE

(EXISTING)

TOILET

124A

CORRIDOR

C1SW

CORRIDOR

124S

CORRIDOR

(EXISTING)

ENTRY

123A

LOBBY

120N

ELEV

E03

MECH

120M

C1S

CORRIDOR

KITCHEN

COOLER

LOADING

DOCK

SPS /

LOGISTICS

91 SF

SOILED

HOLDING

95 SF

PROCEDURE

213 SF

CLEAN

STORAGE

42 SF

CLEAN

STORAGE

48 SF

EXAM 6

12O SF

EXAM 12

120 SF

EXAM 11

120 SFEXAM 5

120 SF

TLT

59 SF

TEAM

WORK AREA

500 SF

TEAM

WORK AREA

682 SF

EXAM 10

120 SF

EXAM 4

120 SF

EXAM 3

120 SF

EXAM 9

120 SF

EXAM 15

120 SF

EXAM 14

120 SF

EXAM 8

120 SF

EXAM 2

120 SF

EXAM 1

120 SF

EXAM 7

120 SF

MEDICATION

92 SF

STORAGE

48 SF

CLEAN

STORAGE

68 SF

CLEAN

STORAGE

47 SF

TLT

59 SF

TLT

59 SF

HAC

54 SF

EXAM 13

120 SF

TLT

61 SF

WAITING

840 SF

(32 SEATS)

STAND UP

SCALE

STAND UP

SCALE

SELF

CHECK-IN

KIOSKS

131A

FRIDGE

131B

FRIDGE

C1W

CORRIDOR

100B

STORAGE

C1W

CORRIDOR

LOADING

DOCK

B

STORAGE

MED. STO.

SOILED HOLD

LINEN

PROCEDURE

CLEAN

EXAM 4

EXAM 3

EXAM 2

EXAM 1

TOILET

165A

TOILET

164A

TOILET

172A

TOILET

171A

TOILET

170A

VENDING STO.

174A

VENDING/

BREAK ROOM

REFERRAL

OFFICE

CONFERENCE

STORAGE

HAC

ELEC

FAMILY

FAMILY

175MEETING ROOM

173A

WAITING

RECEPTION

NURSE WORK

CORRIDOR

C1

CORRIDOR

C2

CORRIDOR

C3

CORRIDOR

C4

ELECTRICAL

MECHANICAL

DATA ROOM

WORK ROOM

LOBBY

VESTIBULE

STORAGE

EXISTING

CORRIDOR

E

STAIRWELL

ELECT.

100A

UP

UP

UP

UP

RECEPTION

124L

ENTRY

124M

CONSULTATION

124K

CONSULTATION

124J

CONFERENCE

124I

(EXISTING)

OFFICE

126A

(EXISTING)

TOILET

124A

(EXISTING)

STORAGE

(EXISTING)

CHIEF OFFICE

126MECHANICAL

124R

WAITING

124O

ALCOVE

124P

CORRIDOR

ENTRY

124N

C

F

STAIR

WAITING

OFFICE

OFFICE

OFFICE 134

CONSULT

PATIENT

OFFICE

MECHANICAL

4-TN300

4-TN300

LIMITS OF DATA CABLING DEMOLITION

E

EE

E

E

4B-LI

4B-MSB

4B-ES

UPS-A

4B-ESDP

ATS-4B-ES

4B-ES-DS

4B-EQ-DS

AT-4B-EQ

4B-EQDP

E

E

EE

E E

4B-EQ

EE

E

E

EE

EE

E

E

E

E E

E

E

E E E

E

E

8" x4

8" x4

8" x4

8"x4"

8"x4"

8"x4"

8"x4"8"x4"

8"x4"

8"x4"

8" x4

8"x4"

8" x4

8"x4"

8" x4

E 8"x4" 8"x4"

E

WEST EAST

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

4-TD110

FIRST FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"2

FIRST FLOOR PLAN - TELECOM - DEMOLITION - EAST

1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOM - DEMOLITION - WEST

N

0 8' 16'4'

N

0 8' 16'4'

1" = 50'-0"

KEY PLAN

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

SHEET NOTES:

1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS

THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.

REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING

ROUTES.

OFFICE

FISCAL

OFFICER

FISCAL

OFFICE

FISCAL

RESOURCES

HUMAN

FISCAL

C2WC

CORRIDOR

ROOF

ACCOUNTING

LOBBY

ELEV

MANAGEMENT

QUALITY

MANAGER

QUALITY

COPY

223B

RESOURCES

HUMAN

CONF. ROOM

RISK MANAGE.

PAT. SAFETY

ADMIN

QM

223A

CREDENTIALING

COMPLIANCE

OFFICE

AO

ADPAC

OFFICE

DIRECTOR

AO

EXECUTIVE

NURSE

ASSISTANT

DIRECTOR

SECRETARIES

DIRECTOR

C2E

CORRIDOR

OF STAFF

CHIEF

RM

BREAK

STAIR

BATH245

DIRECTOR

HOSPITAL

HAC

MECH

STAIR

C2C

CORRIDOR

C2EC

CORRIDOR

C2E

CORRIDOR

ATTIC ACCESS

226A

RAMP TO B1-2RAMP UP

STAIR ELEV

STAIR

RESOURCES

HUMAN

RESOURCES

HUMAN

CONTROL

INFECTION

RESOURCES

HUMAN

RESOURCES

HUMAN

RESOURCES

HUMAN

RESOURCES

HUMAN

RESOURCES

HUMAN

MALE

FEMALE

ADPAC

OFFICE

FISCAL

RESOURCES

HUMAN

H.R.

SUPERVISOR

SECRETARY

HR

RESOURCES

HUMAN

ROOF

C2W

CORRIDOR

RESOURCES

HUMAN

4-TN300

LIMITS OF DATA CABLING DEMOLITION

LIMITS OF DATA CABLING DEMOLITION

WAP

WAP

WAP

WAP

WAP

WAP

2D 2D/2V 4D 2D/2V 2D/2V

3D

3D

3D

2D/2V 2D/2V

2V

2D6D

2D/2V

2D 2D/2V 2D/2V 4D 4D 2D/2V 2D/2V

4D 2D/2V

2D/2V 4D

2D/2V

4D 4D 1D

4V

1D

4D 2D/2V

E

E

E

E

E

E

E E E E E

E

E

E E

E

E E E

E

E E E E

E E

E

E

E

E E

E

EE

E

E E

E

E

2D/2V

2D/2V

1D/2V

1D/1V 1D/1V

1D/1V1D/1V 2D/2V 2D/2V

2D/2V 2D/2V 2D/2V 2D/2V 2D/2V 2D/2V

4V 2D E

E

E

E

EEEEEE

EE

EE

E E

E

E

E

E

WAP

WAP

E

WAP

WAP

E 2D/2V

E E

12"x4"12"x4"

LIMITS OF DATA CABLING DEMOLITION 1

2D 3D

2D/2V 3D

2D/2V

2D/2V 2D/2V 2D/2V2D/2V3D2V

4D

E E

E E

E

E EEEE

E

E

EWAP

2D/2V 2D/2V

EE EE EE

EE EE

E

E E

E

2D/2V 2D/2V

2D/2V

4V 5D

1D/1V 2D/2V 2D/2V

2D/2V 2D/2V 2D/2V

2D/2V 2D/2V

EE

E

EE

12"x4"12"x4"

WEST EAST

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

4-TD120

SECOND FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"2

SECOND FLOOR PLAN - TELECOM - DEMOLITION - EAST

1/8" = 1'-0"

SECOND FLOOR PLAN - TELECOM - DEMOLITION - WEST

N

0 8' 16'4'

N

0 8' 16'4'

1" = 50'-0"

KEY PLAN

SHEET NOTES:

1. REMOVE AND REPLACE EXISTING DATA CABLE: REMOVE ALL EXISTING DATA CABLES AND JACKS

THROUGHOUT THIS AREA. REPLACE CABLES AND JACKS 1 FOR 1, AS REQUIRED BY THE NEW WORK PLANS.

REFER TO NEW WORK PLANS FOR SERVING COMMUNICATIONS ROOM LOCATION AND NEW CABLING

ROUTES.

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

R

R

R

R

R

R

R

R

R

R R

R

R

DIETETIC

STORAGE

ELECTRICAL

21A

MECHANICAL

21 MECHANICAL

UNIFINISHED SPACE

HAC

SPS ADMIN/

VENDOR DROP

SPS

CHIEF

OFFICE

26A

CORRIDOR

CON

CORRIDOR

C0S

STAIR

UNFINISHED

SPACE

19B

STORAGE

REFRIGERATION

EQUIPMENT

23A

STAIR

ELEV

E01

HAC

SUPPLY

FRIDGE

13A

CORRIDOR

SPS MECHANICAL

STERILIZATION

PREP ASSEMBLY

SCOPE

PROCESSING

CRAWL

SPACE

SERVICE TUNNEL

DIRTY

ANTE

MECHANICAL

WOMEN'S

LOCKER ROOM

STAIR

MEN'S

LOKER ROOM

WOMEN'S DECON

LOCKER ROOM

5A

MEN'S DECON

LOCKER ROOM

4A

EXISTING

ELEVATOR

EQUIPMENT

ROOM

DIRTY

LOBBY

DIRTY ELEVATOR

MORGUE

OXYGEN

STORAGE

2A

EQUIP

CLOSET

ELEC

PANELS

CORRIDOR

STAFF LOUNGE

CLEAN ALCOVE

IT

DIRTY

ALCOVE

DIRTY

CORRIDOR

HAC

50 SOAP

DISPENSER

SYSTEM CLOSET

RO

SYSTEM

STORAGE

SCOPE

DECON

CLEAN

ANTE

CORRIDOR

C0W

DECON

WOKR AREA

STAIRS

LOW VOLTAGE

CRAWL SPACE

CRAWL SPACE

TUNNEL TO BUILDING 6

MORGUE

REFRIGERATOR

MECHANICAL

ALCOVE

19C

CORRIDOR

ALCOVE

25A

CORRIDOR

19A

STORAGE

25B

LOW VOLTAGE

2,300 SF

MECHANICAL

UP

STAIRS

UTILITY

ROOM

MECH.

DEMARK

MECH.

UP

CW1

HW1

R

R

R

R

R

R

R

R

R

R R

R

DIETETIC

STORAGE

ELECTRICAL

21A

MECHANICAL

21 MECHANICAL

UNIFINISHED SPACE

HAC

SPS ADMIN/

VENDOR DROP

SPS

CHIEF

OFFICE

26A

CORRIDOR

CON

CORRIDOR

C0S

STAIR

UNFINISHED

SPACE

19B

STORAGE

REFRIGERATION

EQUIPMENT

23A

STAIR

ELEV

E01

HAC

SUPPLY

FRIDGE

13A

CORRIDOR

SPS MECHANICAL

STERILIZATION

PREP ASSEMBLY

SCOPE

PROCESSING

CRAWL

SPACE

SERVICE TUNNEL

DIRTY

ANTE

MECHANICAL

WOMEN'S

LOCKER ROOM

STAIR

MEN'S

LOKER ROOM

WOMEN'S DECON

LOCKER ROOM

5A

MEN'S DECON

LOCKER ROOM

4A

EXISTING

ELEVATOR

EQUIPMENT

ROOM

DIRTY

LOBBY

DIRTY ELEVATOR

MORGUE

OXYGEN

STORAGE

2A

EQUIP

CLOSET

ELEC

PANELS

CORRIDOR

STAFF LOUNGE

CLEAN ALCOVE

IT

DIRTY

ALCOVE

DIRTY

CORRIDOR

HAC

50 SOAP

DISPENSER

SYSTEM CLOSET

RO

SYSTEM

STORAGE

SCOPE

DECON

CLEAN

ANTE

CORRIDOR

C0W

DECON

WOKR AREA

STAIRS

LOW VOLTAGE

CRAWL SPACE

CRAWL SPACE

TUNNEL TO BUILDING 6

MORGUE

REFRIGERATOR

MECHANICAL

ALCOVE

19C

CORRIDOR

ALCOVE

25A

CORRIDOR

19A

STORAGE

25B

LOW VOLTAGE

2,300 SF

MECHANICAL

UP

STAIRS

UTILITY

ROOM

MECH.

DEMARK

MECH.

UP

CRAWL SPACECRAWL SPACE

4"

4"

4-TN403

FB

FB

E

E

E

E

TELECOM ROOM

REDUNDANT DATA CENTER

UPS

REDUNDANT DEMARC

C3 126"

4-TN400

4"4"4"4"

4"4"4"4"

2 2

E E

E

12"x4"

24"x4"

"x

4"

"x

4"

12"x4"

EE

E

E

EE

E

E

E

8" x4

8"x4"

8" x4

8"x4"

8" x4

8"x4"

8" x4

8"x4"

8" x4

EEE

12"x4"

8" x4

12"x4" 12"x4"

E

4"4"4"4"

4"4"4"4"

12"x4"

"x

4"

12"x4"

E

E

E

12"x4"

"x

4"12 "x

4"

24"x4" E

4"4"4"4"

C4 126"

4"4"4"4"4"4"4"4"

FBFB EXISTING

FIBER

TRANSITION

CABINETS

NEW FIBER

TRANSITION

CABINETS

EXISTING

DEMARKCATION

EQUIPMENT

ADJACENT TUNNEL

CABLING TRANSITION

WEST EAST

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:2

:0

P

M

4-TN100

BASEMENT FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"2

BASEMENT FLOOR PLAN - TELECOMMUNICATIONS - EAST

1/8" = 1'-0"1

BASEMENT FLOOR PLAN - TELECOMMUNICATIONS - WEST

N

0 8' 16'4'

N

0 8' 16'4'

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

1" = 50'-0"

KEY PLAN

SHEET NOTES:

1. CONTRACTOR TO PROVIDE NEW WIRE BASKET, AS NEEDED, TO MAINTAIN A 50% OR LESS FILL OF THE CABLE

TRAY SYSTEM FOR THE FLOOR. THE NEW WIRE BASKET WILL MATCH THE SIZE AND DISTANCE, EITHER BESIDE OR BELOW THE EXISTING CABLE TRAY, TO MATCH THE EXISTING TELECOM CABLE TRAY.

2. PROVIDE JUNCTION BOX TO CONNECT FIBER CONDUIT ENTRY TO EXTEND CONDUIT PATHWAY TO THE NEW

TELECOM ROOM.

FEC

FEC

FEC

R E

F

FEC

OFFICE

124H

OFFICE

124G

OFFICE

124F

OFFICE

124E

OFFICE

124D

OFFICE

124C

OFFICE

124B

ALCOVE

124Q

(EXISTING)

OFFICE

(EXISTING)

OFFICE

(EXISTING)

TOILET

124A

CORRIDOR

C1SW

CORRIDOR

124S

CORRIDOR

(EXISTING)

ENTRY

123A

LOBBY

120N

ELEV

E03

MECH

120M

C1S

CORRIDOR

KITCHEN

COOLER

LOADING

DOCK

SPS /

LOGISTICS

91 SF

SOILED

HOLDING

95 SF

PROCEDURE

213 SF

CLEAN

STORAGE

42 SF

CLEAN

STORAGE

48 SF

EXAM 6

12O SF

EXAM 12

120 SF

EXAM 11

120 SFEXAM 5

120 SF

TLT

59 SF

TEAM

WORK AREA

500 SF

TEAM

WORK AREA

682 SF

EXAM 10

120 SF

EXAM 4

120 SF

EXAM 3

120 SF

EXAM 9

120 SF

EXAM 15

120 SF

EXAM 14

120 SF

EXAM 8

120 SF

EXAM 2

120 SF

EXAM 1

120 SF

EXAM 7

120 SF

MEDICATION

92 SF

STORAGE

48 SF

CLEAN

STORAGE

68 SF

CLEAN

STORAGE

47 SF

TLT

59 SF

TLT

59 SF

HAC

54 SF

EXAM 13

120 SF

TLT

61 SF

WAITING

840 SF

(32 SEATS)

STAND UP

SCALE

STAND UP

SCALE

SELF

CHECK-IN

KIOSKS

131A

FRIDGE

131B

FRIDGE

C1W

CORRIDOR

100B

STORAGE

C1W

CORRIDOR

LOADING

DOCK

B

STORAGE

MED. STO.

SOILED HOLD

LINEN

PROCEDURE

CLEAN

EXAM 4

EXAM 3

EXAM 2

EXAM 1

TOILET

165A

TOILET

164A

TOILET

172A

TOILET

171A

TOILET

170A

VENDING STO.

174A

VENDING/

BREAK ROOM

REFERRAL

OFFICE

CONFERENCE

STORAGE

HAC

ELEC

FAMILY

FAMILY

175MEETING ROOM

173A

WAITING

RECEPTION

NURSE WORK

CORRIDOR

C1

CORRIDOR

C2

CORRIDOR

C3

CORRIDOR

C4

ELECTRICAL

MECHANICAL

DATA ROOM

WORK ROOM

LOBBY

VESTIBULE

STORAGE

EXISTING

CORRIDOR

E

STAIRWELL

ELECT.

100A

UP

UP

UP

UP

S

UCF

FEC

FEC

FEC

R E

F

FEC

OFFICE

124H

OFFICE

124G

OFFICE

124F

OFFICE

124E

OFFICE

124D

OFFICE

124C

OFFICE

124B

ALCOVE

124Q

(EXISTING)

OFFICE

(EXISTING)

OFFICE

(EXISTING)

TOILET

124A

CORRIDOR

C1SW

CORRIDOR

124S

CORRIDOR

(EXISTING)

ENTRY

123A

LOBBY

120N

ELEV

E03

MECH

120M

C1S

CORRIDOR

KITCHEN

COOLER

LOADING

DOCK

SPS /

LOGISTICS

91 SF

SOILED

HOLDING

95 SF

PROCEDURE

213 SF

CLEAN

STORAGE

42 SF

CLEAN

STORAGE

48 SF

EXAM 6

12O SF

EXAM 12

120 SF

EXAM 11

120 SFEXAM 5

120 SF

TLT

59 SF

TEAM

WORK AREA

500 SF

TEAM

WORK AREA

682 SF

EXAM 10

120 SF

EXAM 4

120 SF

EXAM 3

120 SF

EXAM 9

120 SF

EXAM 15

120 SF

EXAM 14

120 SF

EXAM 8

120 SF

EXAM 2

120 SF

EXAM 1

120 SF

EXAM 7

120 SF

MEDICATION

92 SF

STORAGE

48 SF

CLEAN

STORAGE

68 SF

CLEAN

STORAGE

47 SF

TLT

59 SF

TLT

59 SF

HAC

54 SF

EXAM 13

120 SF

TLT

61 SF

WAITING

840 SF

(32 SEATS)

STAND UP

SCALE

STAND UP

SCALE

SELF

CHECK-IN

KIOSKS

131A

FRIDGE

131B

FRIDGE

C1W

CORRIDOR

100B

STORAGE

C1W

CORRIDOR

LOADING

DOCK

B

STORAGE

MED. STO.

SOILED HOLD

LINEN

PROCEDURE

CLEAN

EXAM 4

EXAM 3

EXAM 2

EXAM 1

TOILET

165A

TOILET

164A

TOILET

172A

TOILET

171A

TOILET

170A

VENDING STO.

174A

VENDING/

BREAK ROOM

REFERRAL

OFFICE

CONFERENCE

STORAGE

HAC

ELEC

FAMILY

FAMILY

175MEETING ROOM

173A

WAITING

RECEPTION

NURSE WORK

CORRIDOR

C1

CORRIDOR

C2

CORRIDOR

C3

CORRIDOR

C4

ELECTRICAL

MECHANICAL

DATA ROOM

WORK ROOM

LOBBY

VESTIBULE

STORAGE

EXISTING

CORRIDOR

E

STAIRWELL

ELECT.

100A

UP

UP

UP

UP

RECEPTION

124L

ENTRY

124M

CONSULTATION

124K

CONSULTATION

124J

CONFERENCE

124I

(EXISTING)

OFFICE

126A

(EXISTING)

TOILET

124A

(EXISTING)

STORAGE

(EXISTING)

CHIEF OFFICE

126MECHANICAL

124R

WAITING

124O

ALCOVE

124P

CORRIDOR

ENTRY

124N

C

F

STAIR

WAITING

OFFICE

OFFICE

OFFICE 134

CONSULT

PATIENT

OFFICE

MECHANICAL

3'-6"

296 S.F.

7'-1 1_

3'-6"

120 S.F.

120 S.F.

105 S.F.

62. 0000

3'-4"

C o p ie r

8'-9 3_

3'-6"

4'-6 15__

580 S.F.

641 S.F.

RECEPTION

124L

ENTRY

124M

CONSULTATION

124K

CONSULTATION

124J

CONFERENCE

124I

(EXISTING)

OFFICE

126A

(EXISTING)

TOILET

124A

(EXISTING)

STORAGE

(EXISTING)

CHIEF OFFICE

126MECHANICAL

124R

WAITING

124O

ALCOVE

124P

CORRIDOR

ENTRY

124N

C

F

STAIR

WAITING

OFFICE

OFFICE

OFFICE 134

CONSULT

PATIENT

OFFICE

MECHANICAL

3'-6"

296 S.F.

7'-1 1_

3'-6"

120 S.F.

120 S.F.

105 S.F.

62. 0000

3'-4"

C o p ie r

8'-9 3_

3'-6"

4'-6 15__

580 S.F.

641 S.F.

4-TN401

1 185

DATA CENTER

123C

TELECOM ROOM

1C3S

EXIST (NIC) E

EXISTING

ANALOG

COPPER

DISTRIBUTION

RACK E

EXISTING

COPPER

BACKBONE

VERTICAL

ROUTE TO

FLOOR BELOW

EXISTING

FIBER OPTIC

BACKBONE

VERTICAL

ROUTE TO

FLOOR BELOW

"x

4"

NEW

FIBER OPTIC

BACKBONE

VERTICAL

ROUTE TO

FLOOR BELOW

4B-EQ-DS

4B-ES-DS AT-4B-EQ

ATS-4B-ES

4B-ESDP

4B-EQDP

4B-ES 4B-LI

4B-EQ

UPS-A

4B-MSB

ADVANCED…