Atch 14 - BLDG 8 addendum.pdf

PDF 9 MB Posted

Attached to
Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud Federal contract opportunity
Solicitation number
36C77622B0035
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This solicitation seeks a contractor to perform electrical, telecommunications, data infrastructure, HVAC, and hazardous materials abatement work at the St. Cloud Veterans Affairs Health Care System campus in Minnesota. Upgrades are required for electrical bonding, UPS systems, building management system interfaces, access security, data center infrastructure including fiber backbone, and reconfiguration of existing spaces as needed. The work must be completed in accordance with contract drawings and specifications. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.

View the file

Other files for this federal contract opportunity

Other files attached to Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud, newest first.
File Type Posted
Atch 5 - General 2 of 2 addendum.pdf PDF
Atch 15 - BLDG 9 addendum.pdf PDF
Atch 20 - BLDG 29 addendum.pdf PDF
Atch 22 - BLDG 49 addendum.pdf PDF
Atch 24 - BLDG 51 addendum.pdf PDF
Atch 25 - BLDG 54 and 69 addendum.pdf PDF
Atch 32 - BLDG 115 addendum.pdf PDF
OIT Design Requirements - St. Cloud - Backbone Cabling.zip ZIP file
Atch 10 - BLDG 4 addendum.pdf PDF
Atch 21 - BLDG 48 addendum.pdf PDF
36C77622B0035 0002.pdf PDF
Technical Questions - FINAL - St. Cloud 7-28-22.pdf PDF
Atch 2 - Specifications Volume 2 addendum.pdf PDF
Atch 7 - BLDG 1 - 2 of 2 addendum.pdf PDF
Atch 16 - BLDG 10 addendum.pdf PDF
Atch 19 - BLDG 28 addendum.pdf PDF
Atch 23 - BLDG 50 addendum.pdf PDF
Atch 26 - BLDG 95 and 88 addendum.pdf PDF
Atch 29 - BLDG 109 and 57 addendum.pdf PDF
Atch 34 - BLDG 118 addendum.pdf PDF
36C77622B0035 0001.pdf PDF
Atch 1 - Specifications Volume 1.pdf PDF
Atch 7 - BLDG 1 - 2 of 2.pdf PDF
Atch 12 - BLDG 6.pdf PDF
Atch 15 - BLDG 9.pdf PDF
Atch 18 - BLDG 14.pdf PDF
Atch 21 - BLDG 48.pdf PDF
Atch 25 - BLDG 54 and 69.pdf PDF
Atch 26 - BLDG 95 and 88.pdf PDF
Atch 28 - BLDG 108.pdf PDF
Atch 30 - BLDG 111.pdf PDF
Atch 32 - BLDG 115.pdf PDF
Atch 36 - Parking Structure.pdf PDF
Atch 40 - Limitations on Subcontracting - Construction.docx DOCX document
Atch 43 - Site Visit Instructions.pdf PDF
Atch 20 - BLDG 29.pdf PDF
Atch 2 - Specifications Volume 2.pdf PDF
Atch 3 - Specifications Volume 3 - Asbestos.pdf PDF
Atch 9 - BLDG 3.pdf PDF
Atch 11 - BLDG 5.pdf PDF
Atch 13 - BLDG 7 and 13.pdf PDF
Atch 14 - BLDG 8.pdf PDF
Atch 17 - BLDG 11.pdf PDF
Atch 29 - BLDG 109 and 57.pdf PDF
Atch 33 - BLDG 116.pdf PDF
Atch 37 - Brand Name Justification - St. Cloud.pdf PDF
Atch 38 - Contractor Core Work Hours.pdf PDF
Atch 39 - COVID-19 Safety Protocols 12-14-21.pdf PDF
Atch 41 - Construction Wage Rates - Stearns 4-1-22.pdf PDF
Atch 42 - Contractor Safety - Environmental Form.docx DOCX document
Show all 50

Y1AZ--EHRM Infrastructure Upgrades Construction - St. Cloud has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEGEND

CORRIDOR OUTLINE

VFY EXIST

BUILDING OUTLINE

VFY EXIST

TO 8TH ST WEST ONLYTO 8TH ST EAST & WEST

44TH AVE.

TRAIL 1

TRAIL 2

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2)

15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

GRAVEL

GRAVEL

GRAVEL

EXISTING

ROAD

CHAIN LINK FENCE

CHAIN LINK FENCE

16' GATE

GRAVEL

ELECTRICAL

SUBSTATION

G E N E R A T O R

FUEL LINES

CONDU ITS TO TU NNEL

M V

D U

C T

B A

N K

1 1 2 W

PHARMACY ADDITION

11 2 E

G E N E R A T O R

B

CORRIDOR LINK

A

C T

TR

A

IL

ER

174 s .f.

256 s .f.

185 s .f.

149 s ..f.

155 s .f.

104 s .f.

70 s. .f .

72 s .f.

110 s .f.

276 s .f.

112 s .f.

99 s .f.

57 s .f.

146 s .f.

434 s .f.

R A

MP

U P

1:

M A X

R A

MP

U P

1:

M A X

RA

M P

UP

1:2 0 M

AX

TRANSFER

SWITCH

CAPACITOR

BANK (3)

SWITCH

(2) 15KV

MAIN

SW

BATT

35 KV

TO

15 KV

TRANSFORMER

35KV

FUSED

SWITCH

METER 35KV

SWITCH

.3

TRANSFORMER

BUILD ING

#91

5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

EXISTIN G G AS SU P P LY EQ U IP M EN T TO R EM AIN

O P ER ATIO N AL DU R IN G D EM O LITIO N AN D N EW

C O N STR U C TIO N. P R O TEC T EQU IP M EN T AN D

P IP ELIN ES IN AC C O R D AN C E W ITH G AS SU P P LIER 'S

R EC O M M EN D ATIO N S

N EW G AS SU P P LY M AIN

IN TO B U ILD IN G

SP AR E

P H O N E LIN E

EXTEN D S TO

E XISTIN G

P H O N E IN

B O ILER R O O M

P ER P LAN .

SP AR E

P H O N E

LIN E TO

M ETER

TU N N EL

E XTEN D S

A D D ITIO N AL

2'- 0" U N D ER

B U ILD IN G

FUEL LINE

VENT LINE

1,000 GAL.

UNDERGROUND

DIESEL FUEL

TANK

1,000/5,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

1,000 GAL.

UNDERGROUND

DIESEL FUEL TANK

S 1

LIG H T

N EW G AS SU P P LY

(C O O R D IN ATE W ITH SU P P LIER )

12"D

10"D

"D

TP TP

EXIST. BUILDING

EXIST.

BUS STOP

CC

L O

O P

16"

20"

12"

3"

8"

DN

0.

0’

BIRDCAGE

B

IR

D C

A G

E

NSP ELECTRICAL

FOR HWY DEPT

T101

I.T.

CHILLER

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

C O

NC

. B

LO

CKS

PAT

I O

VESTIBULE

DN

DN

DN

FD

DN

F B

F

B

F B

F

B

F B

F

B

SOUTH

VESTIBULE

PASS

THROUGH

LINK TO

BUILDI NG 51

6 3. 32 56

1 13 5. 35 78

PARKING

NO

PARKING

93 49

37 6

109 5

1A

S M

O K

E B

L D

G

SMOKE

BLDG

SMOKE

BLDG

S M

O K

E B

L D

G

SMOKE

BLDG

M.H.

STOR.

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

SMOKE

BLDG

STOR.

BIO-

HAZ.

SAUK RIVER

GP

HOLDING POND

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

OWNER AND

CONSULTANTS:

CONTACT:

ADDRESS:

MIKE ENGMARK

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

NAME:

ADDRESS:

CONTACT:

ADVANCED STRUCTURAL TECHNOLOGIES

7301 OHMS LANE; SUITE 215

EDINA, MN 55439

ZACHARY CRAIG

PHONE:

NAME:

ADDRESS:

CONTACT:

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

PHONE: 402-991-5520

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

NAME:

ADDRESS:

CONTACT:

PHONE:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

IAN WEBER

763-412-4000

ARCHITECT:

ANDERSON ENGINEERING OF MN, LLC

13605 1ST AVE NORTH, SUITE 100

PLYMOUTH, MN 55441

EDWARD MARKFORT

763-412-4000

952-854-9302

SPECIALIZED ENGINEERING SOLUTIONS

10360 ELLISON CIRCLE

OMAHA, NE 68134

KRIS BURNHAM

402-991-5520

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

COVER

DATE:

APPROVED: APPROVED: PROJECTS SECTION MANAGER

APPROVED: OIT MANAGER DATE: APPROVED: ASSISTANT CHIEF ENGINEER DATE:

APPROVED: SAFETY MANAGER

APPROVED: CHIEF OF POLICE

APPROVED: PATIENT SAFETY

DATE:

DATE:

DATE: APPROVED: EMS MANAGER

APPROVED: M/O MANAGER

DATE:

DATE:

DATE:DATE:

APPROVED: MEDICAL CENTER DIRECTOR

APPROVED: PROJECT COR DATE:

APPROVED: INFECTION CONTROL NURSE DATE:

APPROVED: SERVICE LINE DIRECTOR

APPROVED: GEMS COORDINATOR DATE:

DATE:

APPROVED: NURSE EXECUTIVE

APPROVED: CHIEF OF STAFF DATE:

APPROVED: DIRECTOR FMS

APPROVED: ASSOCIATE DIRECTOR

DATE:

DATE:

DATE:

DATE:APPROVED: DATE:

APPROVED: DATE:

APPROVED: DATE:

Main Campus, St. Cloud, Minnesota St. Cloud VA Health Care System

N

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

VICINITY MAP:

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PHONE: 320-252-1670

CIVIL ENGINEER:

VA COR:

TELECOMMUNICATIONS ENGINEER:

CONTACT:

ADDRESS:

JONATHAN WEST

ST CLOUD VA MEDICAL CENTER

4801 VETERANS DRIVE

ST. CLOUD, MN 56303

PHONE: 504-250-2699

PROGRAM MANAGER:

EMAIL: Jonathan.West@vciint.com

STRUCTURAL ENGINEER:

MECH/ELEC/PLUMB/FIRE ENGINEER:

C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -8

-R E

M a rk fo rt

.r v t

/2

/2

:1

:5

P

M

8-GI000

BUILDING 8 COVER SHEET &

SHEET INDEX

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

BUILDING 8 - EHRM INFRASTRUCTURE UPGRADES

03/30/2022

0APPROX 150' 300'75'

SHEET INDEX - BUILDING 8

SHEET NO. SHEET TITLE

8-GI000 BUILDING 8 COVER SHEET & SHEET INDEX

8-GI111 FIRST FLOOR - INFECTION CONTROL & PHASING PLAN

8-HA-1A REFERENCE - BASEMENT FLOOR ASBESTOS RE-SURVEY

8-HA-2A REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY

8-HA-3A REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY

8-HA-4A REFERENCE - ATTIC ASBESTOS RE-SURVEY

8-AS100 BASEMENT FLOOR - OVERALL PLAN

8-AS110 FIRST FLOOR PLANS

8-AS120 SECOND FLOOR - OVERALL PLAN

8-TD101 BASEMENT FLOOR PLAN - TELECOM - DEMOLITION

8-TD110 FIRST FLOOR PLAN - TELECOM - DEMOLITION

8-TN101 BASEMENT FLOOR PLAN - TELECOMMUNICATIONS

8-TN110 FIRST FLOOR PLAN - TELECOMMUNICATIONS

8-TN200 FIRST LEVEL FLOOR PLAN - TELECOM - CABLE DISTANCE

8-TN400 ENLARGED PLANS - TELECOMMUNICATIONS

08-E100 FIRST FLOOR DEMOLITION PLAN - ELECTRICAL

08-E200 BASEMENT FLOOR PLAN - ELECTRICAL

08-E201 FIRST FLOOR PLAN - ELECTRICAL

08-E300 ELECTRICAL ENLARGED PLANS

08-E400 ELECTRICAL ONE-LINE DIAGRAMS

08-E500 ELECTRICAL SCHEDULES

08-M101 FIRST FLOOR DEMOLITION - MECHANICAL

08-M201 FIRST FLOOR REMODEL - MECHANICAL

SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION

ROOM SCHEDULE

NO. NAME C

A

B

LI

N G

P A

T C

H P

A N

E L

F

IB

E R

P O

W E

R

B O

N D

IN

G

U P

S

D E

D

IC

A T

E D

C O

O

LI

N G

T E

M P

E R

A T

U R

E

H U

M

ID

IT

Y

R A

C K

S E

N S

O R

S P

A C

E

AREA

WIDTH

(FT)

LENGTH

(FT)

HT TO

CLG

STRUCT REMARKS

BASEMENT

012A EXIST RM 15 SF 5.2 2.9 9.83 DECOMMISSION EXIST IT/DATA ROOM. SEE TELECOM

DRAWINGS. RELOCATE FUNCTION TO ROOM 116

FIRST FLOOR

116 TELECOM ROOM X X X X X 110 SF 8.7 12.6 11.00 UPDATE EXIST IT/DATA ROOM TO EHRM TELECOM

ROOM STANDARDS. SEE TELECOM DRAWINGS

OPENING SCHEDULE

VA Building Number

ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION

H D

W G

R O

U P

F

IR

E L

A B

E L

(M

IN

G A

S K

E T

E

LE

C T

R

IC

A L

S L

A B

E L

COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT

PANEL

TYPE

2ND

PANEL

TYPE

PANEL

GLAZING FRAME TYPE

FRAME

GLAZING

HAZARDOUS MATERIAL SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

QUESTIONABLE HAZARDOUS

ELEMENT POSSIBLE ABATEMENT ACTION

BASEMENT 012A EXIST RM ASBESTOS CONTAINING MASTIC

UNDER FLOOR TILE. SEE 8-HA-1A

NONE. ACM TO REMAIN UNDISTURBED

FIRST FLOOR 116 TELECOM ROOM NONE. SEE 8-HA-2A NONE. ABATEMENT COMPLETE UNDER SEPARATE CONTRACT

HAZARDOUS MATERIALS MAY BE ENCOUNTERED THROUGHOUT THE DISTRIBUTION ROUTING THROUGH CEILING PLENUMS AND UTILITY TUNNELS. INSTALLATION OF DISTRIBUTION SHALL NOT DISTURB

QUESTIONABLE HAZARDOUS MATERIAL.

ICRA PHASE CONSTRUCTION ROOM SCHEDULE

LEVEL

ROOM

NO. ROOM NAME

CAI BLDG NAME /

FUNCTION

CONSTRUCTION

PROJECT ACTIVITY

INFECTION CONTROL

RISK GROUP

CONTROL

PROCEDURE CLASS SECTION

CONSTRUCTION ZONE /

OCCUPIED CONSTR

DAY /

NIGHT

BASEMENT 012A EXIST RM RECREATION TYPE B GROUP 1 CLASS II EAST OCCUPIED CONSTRUCTION DAY

FIRST FLOOR 116 TELECOM ROOM RECREATION TYPE C GROUP 1 CLASS II EAST ZONE8 DAY

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

1 UPDATE TO BID DOCUMENTS 06/29/22

STAGE

112A

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREATION

SECRETARY

VOLUNTARY

SERVICE

OFFICE

108A

VOLUNTEER

SERVICE

LOBBY

100B

LOBBY

MAIN

LOBBY

CORRIDOR

PHONE

CLOSET

116A

HAC

STAIR

STORAGE

112C

STORAGE

112B

MALE

TELECOM

ROOM

ZONE 8

INFECTION CONTROL RISK ASSESSMENT (ICRA) LEGEND

LIMITS OF CONSTRUCTION

1 HOUR FIRE RATED ICRA / CONSTRUCTION BARRIER

LOCATION, AND DOOR, WHERE SHOWN

TEMPORARY NON-RATED (PLASTIC SHEETING) CONSTRUCTION BARRIER

LOCATION, WHERE APPROVED BY THE VA FOR USE IN RISK TYPE B.

UPGRADE TO 1 HOUR RATED PARTITION WHEN DIRECTED BY THE VA

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -8

-R E

M a rk fo rt

.r v t

/2

/2

:3 :5

A

M

8-GI111

FIRST FLOOR - INFECTION

CONTROL & PHASING PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM BMW

16305

03/30/2022

1/8" = 1'-0"

FIRST FLOOR - CONST BARRIER PLAN

ROOM ICRA SCHEDULE

LEVEL

ROOM

NO. ROOM NAME CAI BLDG NAME / FUNCTION CONSTRUCTION PROJECT ACTIVITY INFECTION CONTROL RISK GROUP CONTROL PROCEDURE CLASS

BASEMENT 012A EXIST RM RECREATION TYPE B GROUP 1 CLASS II

FIRST FLOOR 116 TELECOM ROOM RECREATION TYPE C GROUP 1 CLASS II

SEE GENERAL NOTES SHEET FOR CONSTRUCTION INFECTION CONTROL RISK ASSESSMENT (ICRA) DESCRIPTIONS. TYPE, GROUP AND CLASS SELECTED TO BEST OF DESIGN TEAM'S KNOWLEDGE.

FINAL DETERMINATION BY THE VA WILL BE MADE AT A LATER DATE.

N

0 8' 16'4'

-ASBESTOS-CONTAINING FIRE DOOR

-ASBESTOS-CONTAINING 9"X9" FLOOR TILE AND MASTIC

-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE

-ASBESTOS-CONTAINING WINDOW CAULK AND GLAZING

-ASBESTOS-CONTAINING WINDOW CAULK

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

BUILDING #8 - BASEMENT FLOOR PLAN

-ASBESTOS-CONTAINING FIRE DOOR

-ASBESTOS-CONTAINING 9"X9" FLOOR TILE AND MASTIC

-ASBESTOS-CONTAINING 12"X12" FLOOR TILE AND MASTIC

-ASBESTOS-CONTAINING MASTIC UNDER CARPET

-ASBESTOS-CONTAINING AIR CELL PIPE INSULATION

-ASBESTOS-CONTAINING MASTIC UNDER 12"X12" FLOOR TILE

-ASBESTOS-CONTAINING WINDOW GLAZING

-ASBESTOS-CONTAINING BLACK WALL MASTIC

CASTLE HILL ASSOCIATES, LLC.

N

S

W

E

LEGEND

BUILDING #8 - FIRST FLOOR PLAN

-POSITIVE SAMPLE LOCATION

-SAMPLE LOCATION

CT3

CT2

CT1

-ASBESTOS-CONTAINING WINDOW CAULK AND GLAZING

CASTLE HILL ASSOCIATES, LLC.

N

S

W E

BUILDING #8 - SECOND FLOOR PLAN

CASTLE HILL ASSOCIATES, LLC.

S

W E

NO ACM

BUILDING #8 - ATTIC FLOOR PLAN

SERVICE

ROOM

BATH

RECREATIONAL

ACTIVITIES

STORAGE

STORAGE

CORRIDOR

FAN

ROOM

MUSIC

ROOM

TOILET

STORAGE

STORAGE

STORAGE

LOUNGE

STORAGE

1A

MECH

LOBBY

ALCOVE

STORAGE

14A

T E

LE

P

H O

N E

C

LO

S E

T A

DAV

OFFICE

1B

WH

2'-10 3/4"

5' -2

/2

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -8

-R E

M a rk fo rt

.r v t

/2

/2

:3 :0

A

M

8-AS100

BASEMENT FLOOR - OVERALL

PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

1/8" = 1'-0"

BASEMENT FLOOR - OVERALL PLAN

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFCATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREATION

SECRETARY

VOLUNTARY

SERVICE

OFFICE

108A

VOLUNTEER

SERVICE

LOBBY

100B

LOBBY

MAIN

LOBBY

CORRIDOR

PHONE

CLOSET

116A

HAC

STAIR

STORAGE

112C

STORAGE

112B

MALE

TELECOM

ROOM

8'-8"

'-7

/4

8-AS110

TELECOM

ROOM

CORRIDOR

KITCHEN

116A

PHONE

CLOSET

IN-03.01

2'-10" 2'-6" 3'-3"

TELECOM

ROOM

TELECOM

ROOM

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -8

-R E

M a rk fo rt

.r v t

/3

/2

:0 :1

P

M

8-AS110

FIRST FLOOR PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR - OVERALL PLAN

1/4" = 1'-0"

ENLARGED FLOOR PLAN

N

0 4' 8'2'

N

0 8' 16'4' 1/4" = 1'-0"

PARTIAL DEMOLITION PLAN

N

0 8' 16'4' 1/4" = 1'-0"

REFLECTED CEILING PLAN

FL1

RC1 RC2

_DEMOLITION PLAN KEYED NOTES

DE1 PREPARE WALL FOR PLYWOOD BACKBOARD INSTALLATION AND EHRM

REQUIREMENTS, SEE FLOOR PLAN AND TELECOM DRAWINGS

DE23 PREPARE EXISTING PARTITION FOR LEAK PREVENTION BARRIER. SEE

FLOOR PLAN AND SHEET AS601

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_FLOOR PLAN KEYED NOTES

FL1 ALL FOUR PERIMETER WALL PARTITIONS APPLY 4' BY 8' AC GRADE ¾”

TRADE SIZE FIRE RATED PLYWOOD BACKBOARD FINISHED WITH

HIGH-GLOSS WHITE PAINT OVER TWO COATS OF FIRE RESISTANT PAINT

FOR SERVICE PROVIDER / SECURITY / VIDEO / ET CETERA. DO NOT PAINT

OVER FIRE RATING STAMP.

FL3 UPGRADE PARTITION TO 1 HOUR FIRE AND SMOKE BARRIER. PROVIDE

TESTED HEAD OF PARTITION ASSEMBLY WITH MATERIALS THAT RESIST

THE PASSAGE OF SMOKE. SEAL JOINT AT HEAD AND ALL PENETRATIONS

WITH FIRE CAULK.

FL20 TELECOM EQUIPMENT, SEE TELECOM DRAWINGS.

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

_REFLECTED CEILING PLAN KEYED NOTES

RC1 LED LIGHTING, SEE ELECTRICAL. IN FRONT OF AND BEHIND CABINET

ROWS PROVIDE 500 LUMENS IN HORIZONTAL AND 200 LUMENS IN THE

VERTICAL AT 3 FT AFF. OPERATED BY MOTION SENSOR PER CABINET

ROW OR SECTION.

RC2 OPEN TO STRUCTURAL FLOOR ABOVE

NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN

DE1 DE1

DE1

FL20

FL3

FL3

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFCATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

DE23

1 UPDATE TO BID DOCUMENTS 06/29/22

D E

S K

D E

S K

D E

S K

D E

S K

T Y

P E

S T

A N

D

CABINET

CAB TABLE

CAB

AUDITORIUM

BELOW

FLY

LOFT

STOR E01

ELEV

STOR

LOBBY

201C

OFFICE

201A

OFFICE

201B

STOR

BALCONY

201D

OFFICE

CORRIDOR

SLATE

METAL ROOF

ROOF

OVER REC. OFFICE

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of

Minnesota.

Name:

Date: License Number: MN# 18157

Typed or Printed Name: Tom Olesak

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10 C

U s e rs

\P u b li c \D o c u m e n ts \R e v it

P ro je c ts

\1 -8

-R E

M a rk fo rt

.r v t

/2

/2

:3 :5

A

M

8-AS120

SECOND FLOOR - OVERALL

PLAN

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

EM EM

16305

03/30/2022

1/8" = 1'-0"

SECOND FLOOR - OVERALL PLAN

N

0 8' 16'4'

_SHEET NOTES

1. SEE GENERAL NOTES AND CAMPUS DRAWINGS FOR GENERAL

INFORMATION, LIFE SAFETY, ICRA, AND PHASING

2. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING

CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO

THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECTS AND

ENGINEERS.

3. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS

AND PHOTOGRAPHS PROVIDED BY THE C.O.R. COMBINED WITH

OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND

ENGINEERS.

4. SEE CIVIL, STRUCTURAL, TELECOM, ELECTRICAL, MECHANICAL, AND

PLUMBING DRAWINGS AND SPECIFCATIONS FOR ADDITIONAL

DEMOLITION AND CONSTRUCTION REQUIREMENTS.

5. PORTABLE FIRE EXTINGUISHERS (CO2 OR HALOGENATED TYPE AS

DETERMINED BY VA) WITH WALL MOUNT BRACKET AND CODE REQUIRED

SIGNAGE SHALL BE PROVIDED BY THE CONTRACTOR WITHIN TELECOM

ROOMS.

MECH

LOBBY 14

ALCOVE

BATH

12A

PHONE

ROOM

SERVICE

ACTIVITIES

RECREATIONAL

14A

MECH

LOUNGE

1A

STORAGE

1B

OFFICE

DAV

ROOM

MUSIC

ROOM

FAN

CORRIDOR

STORAGE 8

BATH

STORAGE

STORAGE

STORAGE

STORAGE

WH

ALCOVE PHONE

8-TD101

LIMITS OF DATA CABLING

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:4

:3

P

M

8-TD101

BASEMENT FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"

BASEMENT FLOOR PLAN - TELECOM - DEMOLITION

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE

RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE

PROJECT.

1. ROOM 012A

EXISTING CABLE COUNT

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

N

0 4' 8'2'

N

0 8' 16'4'

1/4" = 1'-0"

ENLARGED PLAN - TR 012A - TELECOM - DEMO

SHEET NOTES:

1. RETAIN DATA CABLE: EXISTING DATA CABLE THROUGHOUT THIS AREA IS SUFFICIENT TO REMAIN. NEW

CABLING NOT REQUIRED. RETAIN EXISTING CABLING IN SERVICE.

2. DEMO RACK AND DATA CABLES NO LONGER IN USE OUT OF ROOM 12A. ALL PHONE CABLES AND EQUIPMENT TO REMAIN AS IS. EXISTING CABLE TRAY, SECURITY CAMERAS, GROUND BUS BARS, AND RACKS FROM

DECOMMISSIONED ROOMS ARE TO BE REUSED, WHEN POSSBILE, IN NEW CONSTRUCTION TRS.

PRINTER

L A

T E

R A

L F

IL

E

B O

O K

C A

S E

PRINTER/

FILE

T A

B L E

LATERAL

FILE

BOOKCASE

LOBBY

ELEVATOR

100A

STAIR

100B

LOBBY

MALE

116A

PHONE

KITCHEN

HAC

STAIR

OFFICE

CHIEF

OFFICE

OFFICE 108A

OFFICE

OFFICE

FEMALE

112B

STORAGE

112C

STORAGE

AUDITORIUM 112A

STAGE

8-TD110

LIMITS OF DATA CABLING

E

E

E

E

8" x2

8"x2"

8" x2

8" x2

E

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:4

:4

P

M

8-TD110

FIRST FLOOR PLAN -

TELECOM - DEMOLITION

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOM - DEMOLITION

N

0 8' 16'4'

GENERAL NOTES:

A. REFER TO GENERAL DEMOLITION NOTES ON SHEET T000 FOR ADDITIONAL DEMOLITION SCOPE.

1/4" = 1'-0"

ENLARGED PLAN - TR 116 - TELECOM - DEMO

N

0 4' 8'2'

SHEET NOTES:

1. RETAIN DATA CABLE: EXISTING DATA CABLE THROUGHOUT THIS AREA IS SUFFICIENT TO REMAIN. NEW

CABLING NOT REQUIRED. RETAIN EXISTING CABLING IN SERVICE.

2. ROOM 116 IS A NEW DATA CLOSET. ITEMS WILL BE ADDED TO THE ROOM TO BRING IT TO THE EHARM

STANDARD.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE

RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE

PROJECT.

1. ROOM 116

EXISTING CABLE COUNT

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

BATH

RECREATIONAL

ACTIVITIES

STORAGE

STORAGE

CORRIDOR

FAN

ROOM

MUSIC

ROOM

TOILET

STORAGE

STORAGE

STORAGE

LOUNGE

STORAGE

1A

MECH

LOBBY

ALCOVE

STORAGE

14A

TE

LE

P H

O N

E C

LO

S

E T

A

DAV

OFFICE

1B

WH

SERVICE

ROOM

BATH

RECREATIONAL

ACTIVITIES

STORAGE

STORAGE

CORRIDOR

FAN

ROOM

MUSIC

ROOM

TOILET

STORAGE

STORAGE

STORAGE

LOUNGE

STORAGE

1A

MECH

LOBBY

ALCOVE

STORAGE

14A

TE

LE

P H

O N

E C

LO

S

E T

A

DAV

OFFICE

1B

WH

012A

EXIST RM

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:4

:4

P

M

8-TN101

BASEMENT FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1/8" = 1'-0"

BASEMENT FLOOR PLAN - TELECOMMUNICATIONS

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREATION

SECRETARY

VOLUNTARY

SERVICE

OFFICE

108A

VOLUNTEER

SERVICE

LOBBY

100B

LOBBY

MAIN

LOBBY

CORRIDOR

PHONE

CLOSET

116A

HAC

STAIR

STORAGE

112C

STORAGE

112B

MALE

STAGE

112A

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREATION

SECRETARY

VOLUNTARY

SERVICE

OFFICE

108A

VOLUNTEER

SERVICE

LOBBY

100B

LOBBY

MAIN

LOBBY

CORRIDOR

PHONE

CLOSET

116A

HAC

STAIR

STORAGE

112C

STORAGE

112B

MALE

8-TN400

TELECOM ROOM

2"

C2 126"

E

E

E

E

8" x2

8"x2"

8" x2

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:4

:4

P

M

8-TN110

FIRST FLOOR PLAN -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 8' 16'4' 1/8" = 1'-0"

FIRST FLOOR PLAN - TELECOMMUNICATIONS

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

STA GE

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREA TION

SECR ETA RY

VOLU NTA RY

SERVICE

OFFICE

108A

VOLU NTE ER

SERVICE

LOB BY

100B

LOB BY

MAIN

LOB BY

CORRI DOR

PHONE

CLOSE T

116A

HAC

STAIR

STOR AGE

112C

STOR AGE

112B

MALE

STA GE

112A

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREA TION

SECR ETA RY

VOLU NTA RY

SERVICE

OFFICE

108A

VOLU NTE ER

SERVICE

LOB BY

100B

LOB BY

MAIN

LOB BY

CORRI DOR

PHONE

CLOSE T

116A

HAC

STAIR

STOR AGE

112C

STOR AGE

112B

MALE

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:4

:4

P

M

8-TN200

FIRST LEVEL FLOOR PLAN -

TELECOM - CABLE DISTANCE

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

1" = 30'-0"

FIRST FLOOR PLAN - TELECOM - CABLE DISTANCE

0 30' 60'15'

AC

CR

C

8-TN400

1 - a b

1 - c d

C2 126"

W

"x

4"

"x

4"

"x

4"

DATA RACK

CABLE TRAY

12"x4"

12"x4"

KEYPAD

E

8" x2

AC

NOTES:

1. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.

2. COORDINATE EXACT RACK COUNT AND LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.

3. SEE PROJECT SPECIFICATIONS FOR ADDITIONAL RACK COMPONENTS.

4. RACK ELEVATION SHOWS A FULLY CONFIGURED SAMPLE RACK. CONTRACTOR TO PROVIDE REQUIRED EQUIPMENT TO

SUPPORT THE FINAL DATA COUNT FROM THE ENLARGED NEW SHEET. (NOT TO EXCEED 288 PORTS PER RACK).

5. COORDINATE FINAL RACK COMPONENT LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.

6. CONTRACTOR IS RESPONSIBLE FOR FINAL CABLE COUNT, QUANTITY OF PATCH PANELS, SWITCHES, FIBER ENCLOSURES, BLANKING PANELS, CABLE MANAGEMENT, AND MOUNTING HARDWARE NOT MARKED AS “OIT PROVIDED”.

7. PUNCHDOWN COPPER BACKBONES ON RACK MOUNT PATCH PANELS. TERMINATE ONE (1) PAIR PER PATCH PANEL PORT.

VERTICAL CABLE

MANAGEMENT (TYP)

RACK 1

1U 144 STRAND OM4 AND OS2 DISTRIBUTION PANEL

1U BONDING BUS BAR (BACK) 1U BLANKING PANEL (FRONT)

1U 48 PORT CAT5E BACKBONE PATCH PANEL

1U CABLE MANAGEMENT

1U CABLE MANAGEMENT

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

6U 5KW RACK MOUNT UPS

6U SPACE FOR FUTURE USE. PROVIDE BLANK

PANELS FOR UNUSED SPACES.

V E

R T

IC

A

L R

A C

K P

D U

V E

R T

IC

A

L R

A C

K P

D U

NEMA L21-20R (TYP)

CHANNEL RACK (TYP)

D

PROVIDE DATA CABLE TO RACK

MOUNTED UPS FOR CONNECTION

TO MONITORING SYSTEM

RACK 1

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U 48 PORT CAT6A ANGLED DATA PATCH PANEL

1U CABLE MANAGEMENT

VA OIT PROVIDED 1U 48 PORT SWITCH

2U CABLE MANAGEMENT

VA OIT PROVIDED 1U 48 PORT SWITCH

VA OIT PROVIDED 1U 48 PORT SWITCH

2U CABLE MANAGEMENT

1U CABLE MANAGEMENT

VA OIT PROVIDED 1U 48 PORT SWITCH

2U CABLE MANAGEMENT

VA OIT PROVIDED 1U 48 PORT SWITCH

2U CABLE MANAGEMENT

2U CABLE MANAGEMENT

VA OIT PROVIDED 1U 48 PORT SWITCH

SPACE FOR FUTURE HORIZONTAL CABLE

DISTRIBUTION. PROVIDE BLANKING PANELS FOR

UNUSED SPACES.

Nathan M. TimmNo DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.T

R

.r v t

/1

/2

:4

:4

P

M

8-TN400

ENLARGED PLANS -

TELECOMMUNICATIONS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

03/30/2022

KSB SSK

16305

N

0 2' 4'1'

0 4' 8'2' 0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

GENERAL NOTES:

A. REFER TO GENERAL NOTES ON SHEET T000 FOR ADDITIONAL SCOPE.

CABLING NOTE:

CABLING NOTES:

A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.

THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED

FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE

PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.

1. ROOM 116

EXISTING CABLE COUNT

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

CABLE RELOCATION COUNT

DATA (CAT6): 0

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

EXISTING CABLE TO REMAIN

DATA (CAT6): 105

DATA (CAT5e): 0

DATA (CAT5): 0

DATA (CAT3): 0

FINAL CABLE COUNT

DATA (CAT6A): 0

DATA (CAT6): 105

1/2" = 1'-0"

ENLARGED PLAN - TR 116 - TELECOM - CABLE TRAY AND DATA

1/4" = 1'-0"

1 - a

1/4" = 1'-0"

1 - b

1/4" = 1'-0"

1 - c

1/4" = 1'-0"

1 - d

NO SCALE

COMMUNICATIONS - TYPICAL ONE RACK ELEVATION WITH RACK MOUNT UPS - TR 116

SHEET NOTES:

1. IF ROOM 116 DOES NOT HAVE AN ACCESS CONTROL PANEL, PROVIDE A NEW ACCESS CONTROL PANEL TO BE INSTALLED IN THE TELECOM ROOM. THE CARD READER AND KEYPAD FOR THIS ROOM TO BE WIRED TO THE NEW ACCESS CONTROL PANEL. EXISTING CARD READERS AND KEYPADS WILL BE MOVED TO THE NEW

CONTROL PANEL UNDER A DIFFERENT PROJECT.

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREATION

SECRETARY

VOLUNTARY

SERVICE

OFFICE

108A

VOLUNTEER

SERVICE

LOBBY

100B

LOBBY

MAIN

LOBBY

CORRIDOR

PHONE

CLOSET

116A

HAC

STAIR

STORAGE

112C

STORAGE

112B

MALE

TELECOM

ROOM

08-E300

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:3

:5

A

M

08-E100

FIRST FLOOR DEMOLITION

PLAN - ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

TBD GJL

16305

1/8" = 1'-0"

FIRST FLOOR DEMOLITION PLAN - ELECTRICAL

0 8' 16'4'

N

100% CD 03/30

hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:

ate: 03/30/2022 cense Number: MN# 05-06-2022

BATH

RECREATIONAL

ACTIVITIES

STORAGE

STORAGE

CORRIDOR

FAN

ROOM

MUSIC

ROOM

TOILET

STORAGE

STORAGE

STORAGE

LOUNGE

STORAGE

1A

MECH

LOBBY

ALCOVE

STORAGE

14A

TE

LE

P H

O N

E C

LO

S

E T

A

DAV

OFFICE

1B

WH

8-LB-2 8-MDP 8-LB-1

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/2

/2

:2

:5

P

M

08-E200

BASEMENT FLOOR PLAN -

ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

TBD GJL

16305

1/8" = 1'-0"

BASEMENT FLOOR PLAN - ELECTRICAL

0 8' 16'4'

N

100% CD 03/30

53095

112A

AUDITORIUM

REC.

KITCHEN

STAIR

100A

FEMALE

CHIEF OF

RECREATION

SECRETARY

VOLUNTARY

SERVICE

OFFICE

108A

VOLUNTEER

SERVICE

LOBBY

100B

LOBBY

MAIN

LOBBY

CORRIDOR

PHONE

CLOSET

116A

HAC

STAIR

STORAGE

112C

STORAGE

112B

MALE

TELECOM

ROOM

08-E300

B8IT-1-11

WP

1 CU-8-1

08-E300

B8IT-1-10,12

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:3

:0

A

M

08-E201

FIRST FLOOR PLAN -

ELECTRICAL

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

TBD GJL

16305

1/8" = 1'-0"

FIRST FLOOR PLAN - ELECTRICAL

KEYNOTES:

1. PROVIDE ELECTRICAL CONNECTION TO

CONDENSING UNIT, AS REQUIRED.

COORDINATE FINAL LOCATION AND

CONNECTION REQUIREMENTS WITH

MECHANICAL.

0 8' 16'4'

N

100% CD 03/30

hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:

ate: 03/30/2022

SD

PHONE

CLOSET

116A

E

SD

PHONE

CLOSET

116A

PHONE

CLOSET

116A

TELECOM

ROOM

TELECOM ROOM

TELECOM

ROOM

AC-8-1

B8IT-1

B8IT-1-7

42"

B8IT-1-8

42"

B8IT-1-7

42"

B8IT-1-8

42"

B8IT-1-7

42"

B8IT-1-8

42"

4 5

B8IT-1-1,3,5

B8IT-1-2,4,6

TELECOM

ROOM

A

B8IT-1

AE

B8IT-1

A

B8IT-1

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:3

:0

A

M

08-E300

ELECTRICAL ENLARGED

PLANS

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

TBD GJL

16305

1/4" = 1'-0"

FIRST FLOOR DEMOLITION

ENLARGED - TR 116 - ELECTRICAL

1 1/4" = 1'-0"

FIRST FLOOR - TR116 - POWER &

SIGNAL

31/4" = 1'-0"

FIRST FLOOR ENLARGED - TR 116

- LIGHTING

SHEET NOTES:

1. REFER TO TECHNOLOGY PLANS FOR IT ROOM

LAYOUT AND RACK LAYOUT/DETAILS.

2. REFER TO SHEET 0-GE400 DETAIL LAYOUT &

ONE-LINE OF RACK.

KEYNOTES:

1. DISCONNECT AND REMOVE LIGHTS AND

RECEPTACLES IN AREA OF NEW IT ROOM.

MAINTAIN CIRCUIT CONTINUITY TO ADJOINING

SPACES.

2. INDOOR UNIT TO BE POWERED BY OUTDOOR

UNIT. COORDINATE EXACT LOCATION WITH

M.C.

3. CONNECT SMOKE DETECTOR TO NEAREST

EXISTING SLC.

4. COORDINATE FINAL LOCATION OF

RECEPTACLE L21-20R WITH TELECOM

CONTRACTOR. PROVIDE 3/4"C-4#12, 1#12 GND

TO PANEL FOR EACH RECEPTACLE.

5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-

PHASE, 4-WIRE RACK MOUNTED UPS FOR

EACH RACK TOWER.

6. PROVIDE APC#AP8861 RPDU RACK PDU 2G

WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,

ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R

OUTLETS. PROVIDE TWO PER RACK, MOUNTED

PER MANUFACTURER'S REQUIREMENTS.

0 4' 8'2' 0 4' 8'2' 0 4' 8'2'

N N N

100% CD 03/30

hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:

ate: 03/30/2022

BASEMENT

FIRST FLOOR

B8IT-1

100Y

B-MDP

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:3

:0

A

M

08-E400

ELECTRICAL ONE-LINE

DIAGRAMS & SCHEDULE

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

TBD GJL

16305

NO SCALE

PARTIAL POWER RISER

KEYNOTES:

1. PROVIDE NEW 100A/3P CIRCUIT BREAKER IN

EXISTING PANEL TO MATCH EXISTING TYPE

AND AIC RATING.

100% CD 03/30

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 37.1 A

TOTAL CONNECTED AMPS: 37.08 A

Receptacles 1.26 kVA 100.00% 1.26 kVA TOTAL ESTIMATED DEMAND LOAD: 13.36 kVA

Power 12 kVA 100.00% 12 kVA TOTAL CONNECTED LOAD: 13.36 kVA

Lighting 0.1 kVA 100.00% 0.1 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 36.78 36.97 37.64

Total Load: 4.41 kVA 4.43 kVA 4.51 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

11 WP GFI REC. 20 A 1 0.18 1 -- -- -- -- -- -- 12 --

9 TELECOM LIGHTING 20 A 1 0.1 1 2 20 A CU-8-1 10

7 TELECOM ROOM REC. 20 A 1 0.54 0.54 1 20 A TELECOM ROOM REC. 8

-- 5 -- -- -- -- -- -- 1.67 1.67 -- -- -- -- -- -- 6 --

-- 3 -- -- -- -- -- -- 1.67 1.67 -- -- -- -- -- -- 4 --

1 L21-20R 20 A 3 1.67 1.67 3 20 A L21-20R 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: TELECOM ROOM 116 WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B8IT-1

B-MDP

hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:

ate: 03/30/2022

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d E

H R

M I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.E

R

.r v t

/6

/2

:3

:0

A

M

08-E500 xELECTRICAL SCHEDULES

EHRM INFRASTRUCTURE

UPGRADES

656‐21‐235

TBD GJL

16305

CIRCUIT KEY NOTES:

*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.

TOTAL ESTIMATED DEMAND AMPS: 37.1 A

TOTAL CONNECTED AMPS: 37.08 A

Receptacles 1.26 kVA 100.00% 1.26 kVA TOTAL ESTIMATED DEMAND LOAD: 13.36 kVA

Power 12 kVA 100.00% 12 kVA TOTAL CONNECTED LOAD: 13.36 kVA

Lighting 0.1 kVA 100.00% 0.1 kVA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND

TOTALS*

LOAD SUMMARY

Total Amps: 36.78 36.97 37.64

Total Load: 4.41 kVA 4.43 kVA 4.51 kVA

-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --

-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --

-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --

-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --

-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --

-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --

-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --

-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --

-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --

11 WP GFI REC. 20 A 1 0.18 1 -- -- -- -- -- -- 12 --

9 TELECOM LIGHTING 20 A 1 0.1 1 2 20 A CU-8-1 10

7 TELECOM ROOM REC. 20 A 1 0.54 0.54 1 20 A TELECOM ROOM REC. 8

-- 5 -- -- -- -- -- -- 1.67 1.67 -- -- -- -- -- -- 6 --

-- 3 -- -- -- -- -- -- 1.67 1.67 -- -- -- -- -- -- 4 --

1 L21-20R 20 A 3 1.67 1.67 3 20 A L21-20R 2

K E Y

CKT

NO. LOAD DESCRIPTION

OCPD

AMPS P

WIRE

SIZE

H N G

A B C

WIRE

SIZE

G N H

OCPD

P AMPS LOAD DESCRIPTION

CKT

NO.

K E Y

NOTES:

SCCR: 10 kA

LOCATION: TELECOM ROOM 116 WIRE: 4

FED FROM: 0 A/0P @ GROUND BUS PHASE: 3

ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye

MOUNTING: SURFACE MAIN: 100 A MCB

PANEL B8IT-1

B-MDP

100% CD 03/30

hereby certify that this plan, specification or port was prepared by me or under my direc upervision and that I am a duly Licensed ngineer under the laws of the State of Minn ame:

ate: 03/30/2022

T

REC. KITCHEN

TELECOM ROOM

CORRIDOR

PHONE CLOSET

116A

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTA ARCHITECT/ENGINEER OF STAM

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 1

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.M

R

.r v t

/1

/2

:3

:3

P

M

08-M101

FIRST FLOOR

DEMOLITION -

MECHANICAL

EHRM

INFRASTRUCTURE

UPGRADES

656‐21‐235

RDL DJC

16305

1/2" = 1'-0"

FIRST FLOOR DEMOLITION - MECHANICAL- TELECOM 116

KEYNOTES 1/08-M101:

1. DEMOLISH EXISTING 1" FIRE SPRINKLER LINE TO BE DEMO'D BACK TO

RISER AND PREPARE FOR RECONNECTION.

2. EVACUATE AND CAPTURE EXISTING REFRIGERANT, AND DISPOSE OF

IN ACCORDANCE WITH SPECIFICATIONS AND ALL REGULATORY

REQUIREMENTS. REMOVE AND DISPOSE OF EXISTING SPLIT-SYSTEM

UNIT AND ASSOCIATED PIPING & CONTROLS

3. EXISTING 2-1/2" HYDRONIC PIPING TO REMAIN.

4. REMOVE AND DISPOSE OF EXISTING CONVECTOR HEATING UNIT &

CONTROLS. CAP HWS & HWR PIPING AT FLOOR. COORDINATE FLOOR

PATCHING WITH GENERAL CONTRACTOR.

5. REMOVE AND DISPOSE OF EXISTING 3/4" CONDENSATE LINE DOWN

THROUGH FLOOR TO TERMINATION. AND CAP AT MAIN. COORDINATE

FLOOR PATCHING WITH GENERAL CONTRACTOR.

6. REMOVE AND DISPOSE OF EXISTING THERMOSTAT.

7. REMOVE AND DISPOSE OF EXISTING AIR COOLED CONDENSING UNIT.

COORDINATE WALL PATCHING WITH GENERAL CONTRACTOR.

FIELD VERIFICATION NOTES

1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT

THEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED.

A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE

OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.

B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.

C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS, AND DIFFUSERS.

D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.

E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.

2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN

THEIR BIDANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.

3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.

4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND

ARCHITECT FOR DIRECTION.

N

0 2' 4'1'

100% CD 03/3

T

REC. KITCHEN

TELECOM ROOM

CORRIDOR

PHONE CLOSET

116A

RACK PROVIDED

BY OTHERS

CUH-4

CU-8-1

AC-8-1

CP-8-1

No DATEREVISION

DRAWING TITLE

CHECKED BY

ST.CLOUD, MN 56303

VA MEDICAL CENTER

BUILDING No

LOCATION

DRAWING NO.DRAWN

DWG. OF

PROJECT TITLE

PLOT SCALE

PROJECT NO.

DATE:

CONSULTA ARCHITECT/ENGINEER OF STAM

FULLY

SPRINKLERED

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 1

I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.

Name:

Date: 03/30/2022

License Number: MN#

03/30/2022

B

IM

/2

.0

V A

S t C lo u d

E H

R M

I n fr a s tr u c tu re U p g ra d e s /6

-2

.B

.M

R

.r v t

/1

/2

:3

:3

P

M

08-M201

FIRST FLOOR REMODEL -

MECHANICAL

EHRM

INFRASTRUCTURE

UPGRADES

656‐21‐235

RDL DJC

16305

1/2" = 1'-0"

FIRST FLOOR - MECHANICAL - TELECOM 116

KEYNOTES 1/08-M201:

1. DRIP PAN EXISTING HYDRONIC PIPING. DROP 1" DRIP PAN DRAIN LINE DOWN

TO SERVICE ROOM AND ROUTE TO FLOOR DRAIN. FIELD VERIFY

REQUIREMENTS

2. PROVIDE 1" FIRE SPRINKLER LINE. PROVIDE NEW SPRINKLER HEADS.

3. PROVIDE NEW WALL-MOUNTED DUCTLESS COOLING UNIT AC-8-1.

4. ROUTE NEW REFRIGERANT PIPING TO CU-8-1 UNIT. LOCATE CU-8-1 ON

GRADE.

5. PROVIDE NEW AIR COOLED CONDENSING UNIT. PROVIDE CONCRETE PAD.

REFER TO REFRIGERANT PIPING DETAIL 1/0-GM400 AND PAD MOUNTING

DETAIL 3/0-GM401.

6. PROVIDE NEW THERMOSTAT - WIRE COMMON WITH NEW AC UNIT AND CUH.

7. ROUTE 1" PUMPED CONDENSATE DRAIN APPROXIMATELY 35 FEET NORTH

AND DROP TO MOP SINK IN HAC ROOM 103. FIELD VERIFY REQUIREMENTS.

8. PROVIDE NEW CABINET UNIT HEATER CUH-4. RECONNECT TO EXISTING

HYDRONIC HEATING PIPING.

9. REFERE TO 4/0-GM401 FOR WALL PENETRATION SEALING DETAIL

FIELD VERIFICATION NOTES

1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT

THEIR BID. THE FOLLOWING ITEMS SHALL BE VERIFIED.

A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE

OF WORK, WHETHER EXPLICITLY SHOWN OR NOT.

B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.

C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS, AND DIFFUSERS.

D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.

E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYDRONIC PIPING.

2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN

THEIR BIDANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.

3. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS.

4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND

ARCHITECT FOR DIRECTION.

0 2' 4'1'

N

100% CD 03/3

8-GI000 - BUILDING 8 COVER SHEET & SHEET INDEX
8-GI111 - FIRST FLOOR - INFECTION CONTROL & PHASING PLAN
8-HA-1A - REFERENCE - BASEMENT FLOOR ASBESTOS RE-SURVEY
8-HA-2A - REFERENCE - FIRST FLOOR ASBESTOS RE-SURVEY
8-HA-3A - REFERENCE - SECOND FLOOR ASBESTOS RE-SURVEY
8-HA-4A - REFERENCE - ATTIC ASBESTOS RE-SURVEY
8-AS100 - BASEMENT FLOOR - OVERALL PLAN
8-AS110 - FIRST FLOOR PLANS
8-AS120 - SECOND FLOOR - OVERALL PLAN
8-TD101 - BASEMENT FLOOR PLAN - TELECOM - DEMOLITION
8-TD110 - FIRST FLOOR PLAN - TELECOM - DEMOLITION
8-TN101 - BASEMENT FLOOR PLAN - TELECOMMUNICATIONS
8-TN110 - FIRST FLOOR PLAN - TELECOMMUNICATIONS
8-TN200 - FIRST LEVEL FLOOR PLAN - TELECOM - CABLE DISTANCE
8-TN400 - ENLARGED PLANS - TELECOMMUNICATIONS
08-E100 - FIRST FLOOR DEMOLITION PLAN - ELECTRICAL
08-E200 - BASEMENT FLOOR PLAN - ELECTRICAL
08-E201 - FIRST FLOOR PLAN - ELECTRICAL
08-E300 - ELECTRICAL ENLARGED PLANS
08-E400 - ELECTRICAL ONE-LINE DIAGRAMS
08-E500 - ELECTRICAL SCHEDULES
08-M101 - FIRST FLOOR DEMOLITION - MECHANICAL
08-M201 - FIRST FLOOR REMODEL - MECHANICAL