85_EY302 - EIGHTH FLOOR ELECTRICAL LOW VOLTAGE PLAN.pdf
PDF 529 KB Posted
- Solicitation number
- 36C10F22R0036
View the file
Other files
Show 40 more
Latest 50 of 122 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P S
P S
P S
P S
P S
P S P S P
S
P S
PS
P S
P S
P S
P S
P S
P S
NM
DS
DS
DS
DS
PS PS PS PS PS PS PS
PS
PS
PSPS
PS PSPS
SS
PS
IC
IC
IC
IC
IC
IC
IC
IC IC
IC
ICICIC
IC
IC
IC
IC
IC
IC
IC
IC
PS
PS
CR CR
P S
PS
1 2 3 4 5 6 7 8 9 10 11 11a 12
E
F
G
H
I
J
K
9A
G2
SICU PATIENT ISOLATION ROOM (ACC.)
811B
ICU TOILET
810B
SICU PATIENT ROOM
810A
SICU PATIENT ROOM
809A
SICU PATIENT ROOM
808A
SICU PATIENT ROOM
807A
ICU TOILET
807B
SICU PATIENT ROOM
806A
ICU TOILET
806B
SICU PATIENT ROOM
804A
SICU PATIENT ROOM
805A
ICU TOILET
805B SICU PATIENT ISOLATION ROOM (ACC.)
802B
SICU PATIENT ROOM (ACC.)
803A
ICU TOILET
802C
ICU TOILET
803B
SICU PATIENT ROOM (ACC.)
801A
ANTE ROOM
802A ICU TOILET
801B
TOILET
TOILET
SICU WAITING
SICU PATIENT ISOLATION ROOM (ACC.)
824B
SICU PATIENT
825A
ANTE ROOM
824A
ICU TOILET
824C ICU TOILET
825B
SICU PATIENT ROOM
822A
SICU PATIENT ISOLATION ROOM (ACC.)
823B
ANTE ROOM
823A
ICU TOILET
822B
ICU TOILET
823C
SICU PATIENT ROOM
820A
SICU PATIENT ROOM
821A
ICU TOILET
820B
ICU TOILET
821B
ON-CALL
STAFF TOILET
ON-CALL TOILET/SHOWER
STAFF BREAK
SHARED OFFICE
SINGLE OFFICE
TEAM WORK
COMM
HAC
MED GAS
ELEC
NOURISH.
EQUIP. STORAGE
CLEAN UTILITY
SOILED UTILITY
CLEAN SUPPLY / LINEN
ALCOVE, ICE
ALC-8-2
MEDS
ALCOVE
ALC-8-4
ALCOVE
ALC-8-3
NURSE STATION
ALCOVE
ALC-8-5
ALCOVE
ALC-8-1
ICU TOILET
809B
ICU TOILET
804B
ICU TOILET
808B
STAIR 10
STAIR 8
COMM
ELEVATOR LOBBY
COR-8-1
CORRIDOR
COR-8-2
COMM
ELEVATOR
P-9
ELEVATOR
P-10
ELEVATOR
P-8
ELEVATOR
P-7
ELEVATOR LOBBY
COR-8-7
ELEVATOR
P-12
CORRIDOR
COR-8-4
CORRIDOR
COR-8-6
CORRIDOR
COR-8-5
CORRIDOR
COR-8-9
CORRIDOR
COR-8-10
CORRIDOR
COR-8-8
CORRIDOR
COR-8-3
72"
1TV/1D
1TV/1D 1TV/1D 1TV/1D 1TV/1D
1TV/1D 1TV/1D
1TV/1D
1TV/1D
1TV/1D
1TV/1D1TV/1D
1TV/1D1TV/1D
1TV/1D
1TV/1D
72" 72" 72" 72"
1TV/1D 72" 72" 72"
72"
72"
72"
72"72"
72" 72"72"
1D
1V
1V 1V 1V
1V
1V1V1V1V1V
1V
1V1V1V 1V 1V
1V
NURSE STATION/ TEAM COLLAB.
ALCOVE
ALC-8-8
ALCOVE
ALC-8-7
ANTE ROOM
811A
ICU TOILET
811C
72"
1V 1V
1V
7TH FLOOR ROOF
N
8TH FLOOR SICU
8TH FLOOR KEY PLAN
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
OK ARCH REG. NO. CA02295, EXP. 06/30/2023
OK ENGR REG. NO. CA7127, EXP. 06/30/2021
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
HEALTHCARE PLANNER
OCULUS INC.
1 S. MEMORIAL DR., SUITE 1500
ST. LOUIS, MO 63102
(314) 367-6100
SPUR PROJECT NUMBER: 1791.08
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
/2
/2
:5 :2
A
M
EY302
EIGHTH FLOOR ELECTRICAL LOW
VOLTAGE PLAN
BLP
85 OF 92BEN
100% RFP DOCUMENTS
OKCVAMC OR & SICU
08/02/2021
635-436
OKLAHOMA CITY VA HEALTHCARE SYSTEM
921 NE 13TH ST, OKLAHOMA CITY, OK 73104
N
1/8" = 1'-0"
EIGHTH FLOOR ELECTRICAL LOW VOLTAGE PLAN1
GENERAL NOTES:
A. CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND CONNECTING ALL NEW AND
EXISTING RECONNECTED LOADS IN A BALANCED MANNER.
B. SHADED AREAS INDICATE OUT OF PROJECT SCOPE.
C. DESIGN BUILD TEAM AND A/E OF RECORD MUST FOLLOW ALL CURRENT VA NATIONAL
TIL STANDARDS, INCLUDING VA NATIONAL CAD STANDARDS, THROUGHOUT DESIGN
AND CONSTRUCTION.
No. REVISION DESCRIPTION DATE
File details come from the government source that posted it. Updated .