30_FA001 - FIRE ALARM_MASS NOTIFICATION GENERAL NOTES.pdf

PDF 758 KB Posted

Attached to
Y1AZ--Design Build, Construct SICU and Renovate Operating Rooms
Solicitation number
36C10F22R0036
Issued by

View the file

Other files

File Type Posted
Award Notice 36C10F24C0002.pdf PDF
36C10F22R0036 0004.pdf PDF
36C10F22R0036 0003.pdf PDF
36C10F22R0036 0002.pdf PDF
36C10F22R0036 0001.pdf PDF
36C10F22R0036.pdf PDF
45_PL102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
40_PPD101 - SEVENTH FLOOR -PLUMBING DOMESTIC WATER DEMOLITION PLAN.pdf PDF
61_MHP100 - MECHANICAL DUCT and PIPING PLAN -ROOF LEVEL.pdf PDF
17_AF702 - FINISH PLAN -EIGHTH FLOOR.pdf PDF
07_ELEVATOR NARRATIVE.pdf PDF
52_MDH100 - MECHANICAL DUCT DEMOLITION PLAN -SEVENTH FLOOR.pdf PDF
100 percent RFP PLUMBING CALCS.pdf PDF
48_PJ101 - SEVENTH FLOOR -PLUMBING MEDICAL GAS PLAN.pdf PDF
55_MDP100 - MECHANICAL PIPING DEMOLTION PLAN -SEVENTH FLOOR.pdf PDF
44_PL101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
24_QH105 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 1.pdf PDF
04_FIRE PROTECTION.pdf PDF
OR-SICU 100 percent Digital Material Board.pdf PDF
28_QH109 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
27_QH108 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
84_EY301 - SEVENTH FLOOR ELECTRICAL LOW VOLTAGE PLAN.pdf PDF
4_GI102 - LIFE SAFETY PLAN -EIGHTH FLOOR.pdf PDF
86_EP401 - ELECTRICAL LIGHTNING PROTECTION PLAN.pdf PDF
21_QH102 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 2.pdf PDF
13_AE115 - DIMENSION PLAN -EIGHTH FLOOR.pdf PDF
90_EP504 - ELECTRICAL DETAILS.pdf PDF
88_EP502 - SCHEDULES AND DETAILS.pdf PDF
26_QH107 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 3 and INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
39_PLD102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
9_AE111 - REFERENCE PLAN -SEVENTH FLOOR.pdf PDF
12_AE114 - DIMENSION PLAN -SEVENTH FLOOR.pdf PDF
14_AE211 - REFLECTED CEILING PLAN -SEVENTH FLOOR.pdf PDF
01_Mold Report.pdf PDF
Floor 7 Inventory OKC VAMC.pdf PDF
71_M-704 - MECHANICAL CONTROLS.pdf PDF
56_MDP101 - MECHANICAL PIPING DEMOLTION PLAN -EIGHTH FLOOR.pdf PDF
02_ARCHITECTURAL.pdf PDF
1_GI000 - COVER SHEET.pdf PDF
50_P-600 - PLUMBING SCHEDULES.pdf PDF
82_EL201 - SEVENTH FLOOR ELECTRICAL LIGHTING PLAN.pdf PDF
66_M-502 - MECHANICAL DETAILS.pdf PDF
60_MH103 - MECHANICAL ZONING and CONTROLS PLAN -EIGHTH FLOOR.pdf PDF
06_ELECTRICAL NARRATIVE.pdf PDF
02_STRUCTURAL NARRATIVE.pdf PDF
20_QH101 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 1.pdf PDF
38_PLD101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
Floor 8 Inventory OKC VAMC.pdf PDF
63_MP101 - MECHANICAL HVAC PIPING PLAN -EIGHTH FLOOR.pdf PDF
03_EQUIPMENT.pdf PDF
Show 40 more

Latest 50 of 122 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL:

1. THE CONTRACTOR SHALL CAREFULLY REVIEW ALL APPLICABLE DESIGN

CRITERIA, THESE DRAWINGS, AND THE PROJECT SPECIFICATIONS FOR

IMPORTANT QUALIFICATION, DEFINITION, SUBMITTAL, PRODUCT, INSTALLATION,

AND TESTING REQUIREMENTS.

2. ALL SUBMITTALS, INSTALLATION, AND TESTING SHALL BE COMPLETED IN A

NEAT, WORKMAN-LIKE MANNER.

3. PRODUCT, DESIGN, INSTALLATION, AND TESTING ALTERNATE APPROACHES

AND/OR SUBSTITUTIONS WILL BE CONSIDERED BY THE ENGINEER IF THE

CONTRACTOR PROVIDES WRITTEN, WELL-DOCUMENTED, ENGINEERING-BASED

SUBSTANTIATION FOR PROPOSED ALTERNATIVE.

4. EXISTING FIRE ALARM PANEL SERVING THE SCOPE OF WORK AREA TO BE

REUSED TO PROVIDE COVERAGE FOR THE NEW RENOVATED AREAS.

APPLICABLE CODES AND STANDARDS:

1. VA FIRE PROTECTION DESIGN MANUAL SEVENTH EDITION - DECEMBER 2015

2. NFPA 70 NATIONAL ELECTRIC CODE (2020)

3. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE (2019)

4. NFPA 101 (2018)

5. INTERNATIONAL BUILDING CODE (2018)

AUDIBILITY DESIGN:

1. BECAUSE OF UNPREDICTABLE BACKGROUND NOISES AND PROJECT

CONDITIONS, THE AUDIBILITY DESIGN GOALS SHALL BE CONFIRMED BY

MEASUREMENT WITH CALIBRATED TEST EQUIPMENT. IF RESULTS INDICATE

THAT ADDITIONAL NOTIFICATION APPLIANCES ARE REQUIRED, THE

CONTRACTOR SHALL ADD THEM AT NO ADDITIONAL COST.

2. THE EXPECTED AMBIENT SOUND PRESSURE LEVELS ARE AS FOLLOWS:

A. OFFICES, RESTROOMS, RESIDENT ROOMS, CIRCULATION AREAS: 55 dBA B. MECHANICAL EQUIPMENT AREAS: 85 dBA

3. THE DESIGN GOAL IS FOR THE ALERT TONE PRECEDING THE VOICE MESSAGE

TO REACH THE FOLLOWING SOUND PRESSURE LEVELS (PUBLIC MODE):

A. OFFICES, RESTROOMS, CIRCULATION AREAS: 70 dBA B. MECHANICAL EQUIPMENT AREAS: 100 dBA

4. SPEAKERS MAY BE FIELD-LOCATED WITHIN 6 FT OF THE LOCATION INDICATED

ON THE APPROVED DESIGN WITHOUT CONSULTING THE ENGINEER.

5. PATIENT ROOMS AND OR ROOMS, AS INDICATED ON THE DESIGN DRAWINGS,

WILL BE DESIGNED TO MEET PRIVATE-MODE NOTIFICATION IN ACCORDANCE

WITH NFPA 72. ALARM AUDIBILITY IN THESE AREAS IS REQUIRED TO BE 10 dBA

ABOVE AMBIENT OR PROVIDED WITH VISUAL NOTIFICATION THROUGHOUT.

6. INTELLIGIBILITY OF THE OCCUPANT NOTIFICATION SHALL BE TESTED IN

ACCORDANCE WITH NFPA 72 AND THE VA FIRE PROTECTION DESIGN MANUAL.

QUALITATIVE TESTING IS ALLOWED. ALL SCOPE OF WORK AREAS ARE

REQUIRED TO HAVE A CIS SCORE OF 0.65.

VISUAL NOTIFICATION DESIGN:

1. CLEAR STROBES SHALL BE PROVIDED WHERE INDICATED ON THE APPROVED

DESIGN.

2. STROBES MAY BE FIELD-LOCATED WITHIN 3 FT OF THE LOCATION INDICATED ON

THE APPROVED DESIGN WITHOUT CONSULTING THE ENGINEER. CONSULT

WITH ENGINEER PRIOR TO RELOCATING STROBES MORE THAN 3 FT.

3. ALL STROBES TO BE SYNCED WHERE WITHIN VIEWING DISTANCE OF OTHER

STROBES IN ACCORDANCE WITH NFPA 72.

INITIATING DEVICES:

1. INITIATING DEVICES MAY BE FIELD-LOCATED WITHIN 3 FT OF THE LOCATION

INDICATED ON THE APPROVED DESIGN WITHOUT CONSULTING THE ENGINEER.

CONSULT WITH ENGINEER PRIOR TO RELOCATING INITIATING DEVICES MORE

THAN 3 FT.

CIRCUITS AND CONDUIT:

1. ALL CIRCUITS SHALL BE PROVIDED IN CONDUIT IN ACCORDANCE WITH NFPA 70

AND THE CONDUIT LISTING.

2. NEW SIGNALING LINE CIRCUITS AND NOTIFICATION APPLIANCE CIRCUITS SHALL

BE ARRANGED SO THAT A SINGLE FAULT DOES NOT CAUSE THE LOSS OF

ADDRESSABLE DEVICES ON MORE THAN ONE SMOKE COMPARTMENT.

3. PROVIDE LEVEL 2 PATHWAY SURVIVABILITY IN ACCORDANCE WITH NFPA 72.

INSTALLATION:

1. ALL EQUIPMENT SHALL BE INSTALLED TIGHT TO THE BUILDING STRUCTURE AND

SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO THE BUILDING

STRUCTURE UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL NOT APPRECIABLY DEVIATE FROM THE APPROVED

DESIGN WITHOUT WRITTEN APPROVAL FROM THE ENGINEER.

3. CONTRACTOR TO COORDINATE WITH FIRE SUPPRESSION CONTRACTOR FLOW

AND TAMPER SWITCHES AT EACH SMOKE COMPARTMENT FLOW ASSEMBLY.

TESTING:

1. UNLESS SPECIFICALLY NOTED OTHERWISE, THE CONTRACTOR SHALL

PERFORM ALL ACCEPTANCE TESTING IN ACCORDANCE WITH THE APPLICABLE

DESIGN CRITERIA AND THE EQUIPMENT MANUFACTURER'S INSTRUCTIONS.

2. UNLESS SPECIFICALLY NOTED OTHERWISE, THE CONTRACTOR SHALL

PERFORM TESTING AND PROVIDE DOCUMENTATION PRIOR TO REQUESTING

ENGINEER'S PRESENCE TO WITNESS TESTING.

3. FIRE ALARM SYSTEM SHALL HAVE RE-ACCEPTANCE TESTING PERFORMED IN

ACCORDANCE WITH NFPA 72, CHAPTER 14.

FIRE ALARM GENERAL NOTES

FACP

F

WF

EXISTING GAMEWELL-FCI E3 SERIES

FIRE ALARM CONTROL PANEL

FIRE ALARM LEGEND

SPD SURGE PROTECTIVE DEVICE

FIRE ALARM PULL STATION

AIM ADDRESSABLE INPUT MODULE

WATERFLOW SWITCH

s SMOKE DETECTOR - SPOT TYPE

S SPEAKER

SPEAKER STROBE

SYMBOL MODIFIERS

C ncd nW

CEILING MOUNTED

CANDELA RATING

WATT TAP

VS VALVE SUPERVISORY SWITCH

DH DOOR HOLD OPEN DEVICE

DH DOOR HOLD RELEASE

AOM ADDRESSABLE OUTPUT MODULE

E ELEVATOR RECALL

FAA FIRE ALARM ANNUNCIATOR PANEL

STROBE

F EXISTING WATERFLOW BELL

FACP

WF VS

S

SPD

S

BASEMENT

NOTES:

1. TO DEDICATED 120VAC BRANCH CIRCUIT

2. EXISTING FIRE ALARM CONTROL PANEL (GAMEWELL-FCI E3 SERIES) INSTALLED IN THE

BASEMENT, ROOM BB100.

3. THIS RISER DIAGRAM IS INTENDED ONLY TO CAPTURE THE SYSTEM DESIGN INTENT,

PANEL CONNECTIONS, AND GENERAL CIRCUIT ROUTING REQUIREMENTS. EXACT

QUANTITIES AND TYPES OF DEVICES NECESSARY TO ACCOMPLISH THE DESIGN GOALS

ARE NOT INDICATED. THE INTENT OF THIS RISER DIAGRAM IS TO INDICATE THE GENERAL

SYSTEM CONFIGURATION AFTER SUCCESSFUL COMPLETION OF THE PROJECT.

s AIM AIM F

SEVENTH FLOOR

EIGHTH FLOOR

SS

DH

AOM s

DH

s E

WF VS

s AIM AIM Fs E

FAA

F

17 ANY OTHER SYSTEM TROUBLE X X X 17

SUPERVISORY CONDITIONS A B C D E F G H I J K L M N O P Q

7 WATERFLOW/PRESSURE SWITCH X X X X X X X X 7

8 WATERFLOW SWITCH - ELEVATOR MACHINE ROOM X X X X X X X X X X 8

9 SHUNT TRIP POWER MONITOR X X X 9

10 CONTROL VALVE SUPERVISORY SWITCH X X X 10

A B C D E F G H I J K L M N O P Q

X PERFORM OPERATION/REPORT DEVICE STATUS

NOTE: THIS MATRIX PERTAINS TO SCOPE OF WORK AREA. ALL EXISTING PROGRAMING FOR

BUILDING NOT BE MODIFIED UNLESS REQUIRED BY SOW FOR THIS PROJECT.

TROUBLE CONDITIONS A B C D E F G H I J K L M N O P Q

11 AC POWER FAILURE X X X 11

12 LOW BATTERY X X X 12

13 OPEN CIRCUIT X X X 13

14 GROUND FAULT X X X 14

15 NOTIFICATION APPLIANCE CIRCUIT SHORT X X X 15

16 REMOTE POWER SUPPLY COMMON TROUBLE X X X 16

SYSTEM OUTPUTS

SYSTEM INPUTS

F A

C U

A N

N U

N C

IA

T

IO

N

A C

T

IV

A T

E C

O M

M O

N A

L A

R M

S

IG

N A

L I

N D

IC

A

T O

R

A C

T

IV

A T

E A

U D

IB

L E

A L A

R M

S

IG

N A

L

A C

T

IV

A T

E C

O M

M O

N S

U P

E R

V

IS

O R

Y S

IG

N

A L I

N D

IC

A

T O

R

A C

T

IV

A T

E A

U D

IB

L E

S U

P E

R V

IS

O

R Y

S

IG

N A

L

A C

T

IV

A T

E C

O M

M O

N T

R O

U B

L E

S

IG

N A

L I

N D

IC

A

T O

R

A C

T

IV

A T

E A

U D

IB

L E

T R

O U

B L E

S

IG

N A

L

A C

T

IV

A T

E S

E P

A R

A T

E A

N D

D

IS

T

IN

C T

IV

E

V

IS

IB

L E

A N

N U

C

IA

T

IO

N

D

IS

P L A

Y /P

R

IN

T C

H A

N G

E O

F S

T A

T U

S

N O

T

IF

IC

A

T

IO

N

A C

T

IV

A T

E T

E M

P O

R A

L

A L E

R T

T O

N E

A N

D P

R E

-R E

C O

R D

E D

F

IR

E

V

A C

U A

T

IO

N M

E S

S A

G E

T H

R O

U G

H O

U T

A S

S O

C

IA

T E

D Z

O N

E

A C

T

IV

A T

E S

T R

O B

E S

T H

R O

U G

H O

U T

A S

S O

C

IA

T E

D Z

O N

E

A C

T

IV

A T

E P

R E

-R E

C O

R D

E D

S T

A F

F A

L E

R T

M E

S S

A G

E T

H R

O U

G H

O U

T T

H

B

U

IL

D

IN

G

N O

T

IF

Y F

IR

E

D E

P A

R T

M E

N T

A U

X

IL

IA

R

Y F

U N

C T

IO

N

S

R E

C A

L L E

L E

V A

T O

R T

O D

E S

IG

N

A T

E D

L E

V E

L

R E

C A

L L E

L E

V A

T O

R T

O A

L T

E R

N A

T E

L E

V E

L

A C

T

IV

A T

E E

L E

V A

T O

R H

A T

L

IG

H T

F

L A

S H

IN

G

S H

U N

T T

R

IP

P O

W E

R T

O E

L E

V A

T O

R

R E

L E

A S

E D

O O

R H

O L D

-O P

E N

D E

V

IC

E S

ALARM CONDITIONS A B C D E F G H I J K L M N O P Q

1 MANUAL ALARM PULL STATION X X X X X X X X 1

2 SMOKE DETECTOR - SPOT TYPE X X X X X X X X 2

3 SMOKE DETECTOR - ELEVATOR LOBBY - DESIGNATED RECALL LEVEL X X X X X X X X X X 3

4 SMOKE DETECTOR - ELEVATOR LOBBY - OTHER THAN DESIGNATED RECALL LEVEL X X X X X X X X X X 4

5 SMOKE DETECTOR - ELEVATOR MACHINE ROOM - DESIGNATED LEVEL X X X X X X X X X X X 5

6 SMOKE DETECTOR - ELEVATOR MACHINE ROOM - OTHER THAN DESIGNATED RECALL LEVEL X X X X X X X X X X X 6 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Office Of Construction & Facilities Management Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

OK ARCH REG. NO. CA02295, EXP. 06/30/2023

OK ENGR REG. NO. CA7127, EXP. 06/30/2021

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

HEALTHCARE PLANNER

OCULUS INC.

1 S. MEMORIAL DR., SUITE 1500

ST. LOUIS, MO 63102

(314) 367-6100

SPUR PROJECT NUMBER: 1791.08

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

SEE FRONT COVER SHEET

FOR APPROVAL SIGNATURE

/2

/2

:1 :1

A

M

FA001

FIRE ALARM/MASS NOTIFICATION

GENERAL NOTES

SAB

30 OF 92AWP

100% RFP DOCUMENTS

CONSTRUCT SURGICAL INTENSIVE

CARE UNIT & RENOVATE

OPERATING ROOMS

08/02/2021

635-436

OKLAHOMA CITY VA HEALTHCARE SYSTEM

921 NE 13TH ST, OKLAHOMA CITY, OK 73104

FIRE ALARM RISER DIAGRAM

FACU INPUT/OUTPUT MATRIX

No. REVISION DESCRIPTION DATE

CONSULTANTS:

STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

HEALTHCARE PLANNER

OCULUS INC.

1 S. MEMORIAL DR., SUITE 1500

ST. LOUIS, MO 63102

(314) 367-6100

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

VERTICAL TRANSPORTATION

ENVIRONMENTAL HYGIENIST

TEC-AN, INC.

2517 S. PURDUE AVE.

OKLAHOMA CITY, OK 73128

(405) 681-7076

LERCH BATES

2001 BRYAN ST., SUITE 1930

DALLAS, TX 75201

(972) 294-5221

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

File details come from the government source that posted it. Updated .