EXIT LIGHT
2' x 2' ACOUSIC CEILING TILE (AT1)
GYPSUM BOARD CEILING
2' x 2' LIGHT FIXTURE (REFER ELECTRICAL)
RETURN AIR GRILLE (REFER MECHANICAL)
SUPPLY AIR DIFFUSER (REFER MECHANICAL)
EXHAUST AIR GRILLE (REFER MECHANICAL)
CEILING HEIGHT, ABOVE FINISH FLOOR
RECESSED CAN LIGHT (REFER ELECTRICAL)
2' x 4' LIGHT FIXTURE (REFER ELECTRICAL)
ACCESS DOOR (REFER MECHANICAL)
00'-00"
REFLECTED CEILING PLAN LEGEND
2' x 2' ACOUSTIC CEILING TILE, CLEANABLE (AT2)
CEILING MOUNTED PATIENT EXAM LIGHT FIXTURE (REFER ELECTICAL)
1' x 4' LIGHT FIXTURE (REFER ELECTRICAL)
CEILING, OPEN TO STRUCTUREOTS
CEILING MOUNTED SURGICAL LIGHT FIXTURE (REFER ELECTICAL)
CEILING MOUNTED SURGICAL SERVICE COLUMN
CEILING MOUNTED TRACK WITH CURTAIN
AREA OF NOW WORK
1. ALL SURFACES OF FURRDOWNS TO BE PAINTED P1 U.N.O.
2. PROVIDE HOLD DOWN CLIPS AT VESTIBULES AND AREA NEAR EGRESS DOORS.
GENERAL REFLECTED CEILING PLAN NOTES
1 2 3 4 5 6 7 8 9 10 11 11a
C1
D
E
F
G
H
I
J
K
9A
G2
STORAGE
STORAGE
SCRUB
SCRUB
GAS CYLINDERS
GAS CYLINDERS
IMAGE EQUIP
COMPONENT
ROOM
IMAGE EQUIP
COMPONENT
ROOM
CONTROL ROOM
723B
CONTROL ROOM
723B
HAC
HAC
NEURO EQUIP
NEURO EQUIP
NEUROSURGERY
OR 9
728A
NEUROSURGERY
OR 9
728A
HYBRID OR 10
723A
HYBRID OR 10
723A
SCRUB
SCRUB
HYBRID STORAGE
723C
HYBRID STORAGE
723C
CARDIAC OR 3
720A
CARDIAC OR 3
720A
STAIR 10
STAIR 10
STORAGE
STORAGE
GAS STORAGE
GAS STORAGE
TOILET
TOILET
CORRIDOR
COR-7-10
CORRIDOR
COR-7-10
CORRIDOR
COR-7-12
CORRIDOR
COR-7-12
CORRIDOR
COR-7-11
CORRIDOR
COR-7-11
CORRIDOR
COR-7-9
CORRIDOR
COR-7-9
CORRIDOR
COR-7-8
CORRIDOR
COR-7-8
BIOMED
COMMUNICATION
BIOMED
COMMUNICATION
EXISTING CLEAN
CORE
7F-113
EXISTING CLEAN
CORE
7F-113
CORRIDOR
COR-7-6
CORRIDOR
COR-7-6
CORRIDOR
COR-7-3
CORRIDOR
COR-7-3
POST-OP AREA
POST-OP AREA
CLEAN SUPPLY
CLEAN SUPPLY
MEDICATION
MEDICATION
TOILET
TOILET
STORAGE
STORAGE
SOILED UTILITY
SOILED UTILITY
STORAGE
STORAGE
CLEAN SUPPLY
CLEAN SUPPLY
EQUIPMENT
STORAGE
720C
EQUIPMENT
STORAGE
720C
IT CLOSET
IT CLOSET
ELEVATOR
P-12
ELEVATOR
P-12
EXIST. ELEC
CLOSET
7F-116a
EXIST. ELEC
CLOSET
7F-116a
EXIST. ELEC
CLOSET
7F-116
EXIST. ELEC
CLOSET
7F-116
SOILED UTILITY
SOILED UTILITY
TOILET
TOILET
MEDICATION
MEDICATION
STORAGE
STORAGE
RECOVERY
RECOVERY
ISOLATION BAY
ISOLATION BAY
713 CONSULT
CONSULT
OR COUNTER
702A
OR COUNTER
702A
ELEVATOR LOBBY
COR-7-1
ELEVATOR LOBBY
COR-7-1
ELEVATOR
P-8
ELEVATOR
P-8
ELEVATOR
P-7
ELEVATOR
P-7
ELEVATOR
P-9
ELEVATOR
P-9
ELEVATOR
P-10
ELEVATOR
P-10
STAIR 8
STAIR 8
TOILET
701C
TOILET
701C
TOILET
701B
TOILET
701B
CORRIDOR
COR-7-2
CORRIDOR
COR-7-2
SURGICAL
WAITING
701A
SURGICAL
WAITING
701A
EXIST. TELECOM
7F100
EXIST. TELECOM
7F100
PUMP ROOM &
ABG
720B
PUMP ROOM &
ABG
720B
ANTE ROOM
ANTE ROOM
9'-6"
10'-0"
9'-6"
9'-6"
10'-0"
9'-6"
9'-6"
9'-6"
7'-6"
7'-6"
9'-6"
7'-6"
7'-6"
HAC
HAC
4' -0
2'
-0
1'-8"
2' -6
3'-0"
4' -0
4'
-0
3'-11 3/4"
2' -6
3'-0"3'-0"
7' -4
7'
-4
EQ EQ
'-8
'-5
4' -8
/4
3'
-1
1/
2"EQ EQ
5' -0
9'
-6
9' -6
9'
-6
9' -6
9'
-6
9' -6
5'
-0
5' -0
EQ EQ
3' -6
4'
-0
4'-3 1/2"
5' -0
EQ EQ
3' -0
1'
-6
5' -0
3'-11 1/2" 4'-4 1/2"
4' -5
/2
5' -0
6"
1'-6"6"
6'-6 1/2"
'-8
/2
4' -6
6"
6'-0"6"
4' -6
6"
3'-10 1/2" 6"
'-6
6'-0"
9' -5
/2
2'-5 3/4"
E Q
E Q
EQ EQ
2'-6" 7'-0"
2' -0
1' -6
"10'-0"
EQ 12'-0"
EQ
2'-6"
3' -0
'-0
/4
PATIENT BAY
704A
PATIENT BAY
704A
PATIENT BAY
704B
PATIENT BAY
704B
PATIENT BAY
704C
PATIENT BAY
704C
PATIENT BAY
704D
PATIENT BAY
704D
PATIENT BAY
704E
PATIENT BAY
704E
PATIENT BAY
704F
PATIENT BAY
704F
PATIENT BAY
704G
PATIENT BAY
704G
PATIENT BAY
704H
PATIENT BAY
704H
PATIENT BAY
704J
PATIENT BAY
704J
'-9
'-1
8' -8
'-9
'-9
'-9
'-4
4'
-1
20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 8'-6" 12'-3" 2'-6" 10'-9"
200'-0"
'-0
'-9
10.31
10.31
10.31 10.31
10.31
10.31
10.31
10.31
10.31
10'-8 3/4" 10'-5 3/4"
2'-0"
2' -0
2'-0"
'-0
2'
-0
6' -0
12'-0"EQ EQ
10.32
10.32
10.32
1'-6"
1' -6
1'-6"
10.32
OTS
OTS
10.31
10.31
10.31
10.31
10.3110.31
10.31
10.31
10.31
SCRUB
7F120
GENERAL
O.R. #2
7F122
GENERAL
O.R. #1
7F118
SUB
STERILE
7F113b
SHAFT
SUB
STERILE
7F113a
H.A.C.
7F114
CARDIAC
O.R. #4
7F128CLEAN
UTILITY
7F129
X-RAY
STORAGE
7F130
H.A.C.
7F131 SCRUB
7F132
SUB
STERILE
7F133c
EQ EQ
EQ EQ4'-6" E
Q
E Q
26.04
26.04
26.04
10.31
N
RECOVERY &
SURGICAL WAITING
7TH FLOOR KEY PLAN
POST- OP
OPERATING ROOMS
RATED PARTITIONS & BARRIERS
1 HR FIRE RATING
2 HR FIRE RATING
EXISTING CONSTRUCTION
NEW CONSTRUCTION
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Office Of Construction & Facilities Management Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
OK ARCH REG. NO. CA02295, EXP. 06/30/2023
OK ENGR REG. NO. CA7127, EXP. 06/30/2023
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
HEALTHCARE PLANNER
OCULUS INC.
1 S. MEMORIAL DR., SUITE 1500
ST. LOUIS, MO 63102
(314) 367-6100
SPUR PROJECT NUMBER: 1791.08
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
SEE FRONT COVER SHEET
FOR APPROVAL SIGNATURE
VERTICAL TRANSPORTATION
ENVIRONMENTAL HYGIENIST
TEC-AN, INC.
2517 S. PURDUE AVE.
OKLAHOMA CITY, OK 73128
(405) 681-7076
LERCH BATES
2001 BRYAN ST., SUITE 1930
DALLAS, TX 75201
(972) 294-5221
/2
/2
:1 :1
P
M
AE211
REFLECTED CEILING PLAN - SEVENTH
FLOOR
ECO
14 OF 92JNK
100% RFP DOCUMENTS
CONSTRUCT SURGICAL INTENSIVE
CARE UNIT & RENOVATE
OPERATING ROOMS
08/02/2021
635-436
OKLAHOMA CITY VA HEALTHCARE SYSTEM
921 NE 13TH ST, OKLAHOMA CITY, OK 73104
N
1/8" = 1'-0"
SEVENTH FLOOR REFLECTED CEILING PLAN
No. REVISION DESCRIPTION DATE
KEYNOTE LEGEND
10.31 CEILING MOUNTED CURTAIN TRACK
10.32 DASHED LINE INDICATES CENTERLINE OF LIGHT FIXTURE IN GYPSUM BOARD SOFFIT
26.04 EXISTING LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS