FD
FD
FD
FD
FD
FD
FD
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
2. ALL WALLS TO BE PARTITION TYPE F1 UNLESS NOTED OTHERWISE.
3. ALL WALLS TO EXTEND TO UNDERSIDE OF STRUCTURE ABOVE, UNLESS NOTED OTHERWISE.
4. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.
5. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW
TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.
6. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.
7. DESIGN-BUILD CONTRACTOR TO DEVELOP PHASING OF DEMOLITION AND NEW CONSTRUCTION.
COORDINATE ALL REQUIRED PHASING WITH VA AND COR. PROVIDE AT LEAST 1 WEEK NOTICE
PRIOR TO ANY REQUIRED DOWN TIME.
8. DESIGN BUILD TEAM AND A/E OF RECORD MUST FOLLOW ALL CURRENT VA NATIONAL TIL
STANDARDS, INCLUDING VA NATIONAL CAD STANDARDS, THROUGHOUT DESIGN AND
CONSTRUCTION
GENERAL FLOOR PLAN NOTES
1 2 3 4 5 6 7 8 9 10 11
11a
C1
D
E
F
G
H
I
J
K
9A
G2
STORAGE
STORAGE
SCRUB
SCRUB
GAS CYLINDERS
GAS CYLINDERS
IMAGE EQUIP
COMPONENT
ROOM
IMAGE EQUIP
COMPONENT
ROOM
CONTROL ROOM
723B
CONTROL ROOM
723B
HAC
HAC
NEURO EQUIP
NEURO EQUIP
NEUROSURGERY
OR 9
728A
NEUROSURGERY
OR 9
728A
HYBRID OR 10
723A
HYBRID OR 10
723A
SCRUB
SCRUB
HYBRID STORAGE
723C
HYBRID STORAGE
723C
CARDIAC OR 3
720A
CARDIAC OR 3
720A
STAIR 10
STAIR 10
STORAGE
STORAGE
GAS STORAGE
GAS STORAGE
TOILET
TOILET
CORRIDOR
COR-7-10
CORRIDOR
COR-7-10
CORRIDOR
COR-7-12
CORRIDOR
COR-7-12
CORRIDOR
COR-7-11
CORRIDOR
COR-7-11
CORRIDOR
COR-7-9
CORRIDOR
COR-7-9
CORRIDOR
COR-7-8
CORRIDOR
COR-7-8
BIOMED
COMMUNICATION
BIOMED
COMMUNICATION
EXISTING CLEAN
CORE
7F-113
EXISTING CLEAN
CORE
7F-113
CORRIDOR
COR-7-6
CORRIDOR
COR-7-6
CORRIDOR
COR-7-3
CORRIDOR
COR-7-3
POST-OP AREA
POST-OP AREA
MEDICATION
MEDICATION
TOILET
TOILET
STORAGE
STORAGE
CLEAN SUPPLY
CLEAN SUPPLY
EQUIPMENT
STORAGE
720C
EQUIPMENT
STORAGE
720C
IT CLOSET
IT CLOSET
ELEVATOR
P-12
ELEVATOR
P-12
EXIST. ELEC
CLOSET
7F-116a
EXIST. ELEC
CLOSET
7F-116a
EXIST. ELEC
CLOSET
7F-116
EXIST. ELEC
CLOSET
7F-116
SOILED UTILITY
SOILED UTILITY
MEDICATION
MEDICATION
STORAGE
STORAGE
RECOVERY
RECOVERY
ISOLATION BAY
ISOLATION BAY
CONSULT
CONSULT
OR COUNTER
702A
OR COUNTER
702A
ELEVATOR LOBBY
COR-7-1
ELEVATOR LOBBY
COR-7-1
ELEVATOR
P-8
ELEVATOR
P-8
ELEVATOR
P-7
ELEVATOR
P-7
ELEVATOR
P-9
ELEVATOR
P-9
ELEVATOR
P-10
ELEVATOR
P-10 STAIR 8
STAIR 8
TOILET
701C
TOILET
701C
TOILET
701B
TOILET
701B
CORRIDOR
COR-7-2
CORRIDOR
COR-7-2
SURGICAL
WAITING
701A
SURGICAL
WAITING
701A
EXIST. TELECOM
7F100
EXIST. TELECOM
7F100
ALCOVE
ALC-7-1
ALCOVE
ALC-7-1
PUMP ROOM &
ABG
720B
PUMP ROOM &
ABG
720B
SOILED UTILITY
SOILED UTILITY
CLEAN SUPPLY
CLEAN SUPPLY
STORAGE
STORAGE
TOILET
TOILET
ANTE ROOM
ANTE ROOM
CORRIDOR
COR-7-4
CORRIDOR
COR-7-4
ALIGN
ALIGN
ALIGN
ALIGN ALIGN
ALIGN
ALIGN
ALIGN
ALIGN ALIGN
CORRIDOR
COR-7-5
CORRIDOR
COR-7-5
PATIENT BAY
704B
PATIENT BAY
704B
PATIENT BAY
704A
PATIENT BAY
704A
PATIENT BAY
704C
PATIENT BAY
704C
PATIENT BAY
704D
PATIENT BAY
704D
PATIENT BAY
704E
PATIENT BAY
704E
PATIENT BAY
704F
PATIENT BAY
704F
PATIENT BAY
704G
PATIENT BAY
704G
PATIENT BAY
704H
PATIENT BAY
704H
PATIENT BAY
704J
PATIENT BAY
704J
RECOVERY BAY
711L
RECOVERY BAY
711L
RECOVERY BAY
711K
RECOVERY BAY
711K
RECOVERY BAY
711J
RECOVERY BAY
711J
RECOVERY BAY
711H
RECOVERY BAY
711H
RECOVERY BAY
711B
RECOVERY BAY
711B
RECOVERY BAY
711C
RECOVERY BAY
711C
RECOVERY BAY
711D
RECOVERY BAY
711D
RECOVERY BAY
711E
RECOVERY BAY
711E
RECOVERY BAY
711F
RECOVERY BAY
711F
RECOVERY BAY
711G
RECOVERY BAY
711G
REFRESHMENT
CENTER
701D
REFRESHMENT
CENTER
701D
HAC
HAC
CORRIDOR
COR-7-7
CORRIDOR
COR-7-7
DOC. STORAGE
702B
DOC. STORAGE
702B
ALIGNP
-T
U B
E
RECOVERY BAY
711A
RECOVERY BAY
711A
13.10
A1
K1
FEC
FEC
FEC
K1K1
A1G2
M1
M1
M1
M1
M1
N1
M1
A1
K1
M1
E2
G2
E2G2
G2
G2
N1
L2
G2
G2
G1 E2
K2
L2E2
R1
H1
R1
R1
A1A1
E2
K1
K1
A2G2
A1 A1
E2
A1
K1 C1
G2C1
C1
K1
K1K1 N1
G2
G2G2
B1 A1
A1
G1
K1
K1
N1
G1
G2
E1E1
A1A1
K1
S1
G2
E1
L1 E1
L1
G2 M1
K1
A1
K1
G2
A1
G2G2
A1
G1
A1
A1
G2A1
A1 G1
G1 G2
G1 G1
G2 G1
G1
2.52
2.532.53
2.53
2.53
2.53
2.53
2.52
2.53
2.53
2.53
2.532.53
2.52
2.522.52
2.522.52 2.52
2.53
2.532.53
2.532.53
2.53
2.53
2.53
2.53
2.53
2.53
2.52
2.52
2.53
2.52
2.52
2.53
2.52
2.532.53
2.53
2.52
2.52
2.53
2.53
2.53
2.53
2.52
2.522.522.53
2.532.53
2.53
2.522.52
2.53
2.52
2.52
2.53
2.522.52
2.52
2.52
2.532.532.53 2.53
K1
2.53
2.532.53
E1
G2G2
E2
G2G2 G2G2
SCRUB
7F120
GENERAL
O.R. #2
7F122
GENERAL
O.R. #1
7F118
SUB
STERILE
7F113b
SHAFT
SUB
STERILE
7F113a
H.A.C.
7F114CARDIAC
O.R. #4
7F128
CLEAN
UTILITY
7F129
X-RAY
STORAGE
7F130
H.A.C.
7F131 SCRUB
7F132
SUB
STERILE
7F133c
K1K1
A1
K1
E2
2.53
K1
L2
L2
P1
P1P1P1 P1P1 P1P1
K2
2.53
P1P1 P1P1 P1P1 P1P1
2.53
P1
P1
P1
A2
M1
M1
A2
13.1013.10
13.1013.10
P1
P1P1
P1
P1
P1P1
P1
P1
P1P1
A1
A1
K1K1
E2E2E2 E2
N1N1
E2
N1N1
13.10 13.1013.10
N1
G1N1
N1N1
L2
K1
L2
A2
K2
E2
N1
K1
M1
H1H1
R1
C1
G2
13.1013.1013.10
13.10
13.10
K1
R1
13.10
13.10
S1
S1
P1 P1
G1
G2
G1 K1
P1
G2
G2
G2G2
2.53
A1
P1P1 P1
N1
M1
G2
A1A1
A1
E1 G1
A1
A1A1
S1
NURSE STATION
711M
NURSE STATION
711M
8.13 8.50
P1
P1 G2
N1
9.87
2.65
2.65
8.94
8.94
8.94
8.94 8.94 8.94 8.94
8.94 8.94 8.94
8.94
8.94
8.94
8.94
9.88
9.87 9.88
L2
8.95
N
RECOVERY &
SURGICAL WAITING
7TH FLOOR KEY PLAN
POST- OP
OPERATING ROOMS
RATED PARTITIONS & BARRIERS
1 HR FIRE RATING
2 HR FIRE RATING
EXISTING CONSTRUCTION
NEW CONSTRUCTION
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Office Of Construction & Facilities Management Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
OK ARCH REG. NO. CA02295, EXP. 06/30/2023
OK ENGR REG. NO. CA7127, EXP. 06/30/2023
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
HEALTHCARE PLANNER
OCULUS INC.
1 S. MEMORIAL DR., SUITE 1500
ST. LOUIS, MO 63102
(314) 367-6100
SPUR PROJECT NUMBER: 1791.08
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
SEE FRONT COVER SHEET
FOR APPROVAL SIGNATURE
VERTICAL TRANSPORTATION
ENVIRONMENTAL HYGIENIST
TEC-AN, INC.
2517 S. PURDUE AVE.
OKLAHOMA CITY, OK 73128
(405) 681-7076
LERCH BATES
2001 BRYAN ST., SUITE 1930
DALLAS, TX 75201
(972) 294-5221
/2
/2
:1 :5
P
M
AE111
REFERENCE PLAN - SEVENTH FLOOR
ZDL
9 OF 92JNK
100% RFP DOCUMENTS
CONSTRUCT SURGICAL INTENSIVE
CARE UNIT & RENOVATE
OPERATING ROOMS
08/02/2021
635-436
OKLAHOMA CITY VA HEALTHCARE SYSTEM
921 NE 13TH ST, OKLAHOMA CITY, OK 73104
N
1/8" = 1'-0"
SEVENTH FLOOR REFERENCE PLAN
ROOM SCHEDULE - 7TH FLOOR
ROOM
NO.
ROOM NAME SEPS
CODE
PROGRAM
AREA
ACTUAL
AREA
COMMENTS
701A SURGICAL WAITING - - 377 SF NEUTRAL AIR
701B TOILET TLTU1 60 SF 51 SF NEGATIVE AIR
701C TOILET TLTU1 60 SF 51 SF NEGATIVE AIR
701D REFRESHMENT CENTER - - 51 SF NEUTRAL AIR
702A OR COUNTER - - 62 SF POSITIVE AIR
703 CONSULT - - 98 SF NEUTRAL AIR
704 POST-OP AREA - - 757 SF POSITIVE AIR
704A PATIENT BAY RRPR1 140 SF 124 SF POSITIVE AIR
704B PATIENT BAY RRPR1 140 SF 117 SF POSITIVE AIR
704C PATIENT BAY RRPR1 140 SF 115 SF POSITIVE AIR
704D PATIENT BAY RRPR1 140 SF 129 SF POSITIVE AIR
704E PATIENT BAY RRPR1 140 SF 123 SF POSITIVE AIR
704F PATIENT BAY RRPR1 140 SF 123 SF POSITIVE AIR
704G PATIENT BAY RRPR1 140 SF 136 SF POSITIVE AIR
704H PATIENT BAY RRPR1 140 SF 119 SF POSITIVE AIR
704J PATIENT BAY RRPR1 140 SF 111 SF POSITIVE AIR
705 TOILET TLTU1 60 SF 55 SF NEGATIVE AIR
706 CLEAN SUPPLY SRSE1 100 SF 51 SF POSITIVE AIR
707 SOILED UTILITY USCL1 80 SF 55 SF DOUBLE NEG. AIR
708 MEDICATION MEDP1 100 SF 68 SF NEUTRAL AIR
709 STORAGE - - 47 SF POSITIVE AIR
710 STORAGE - - 71 SF POSITIVE AIR
711 RECOVERY - - 795 SF POSITIVE AIR
711A RECOVERY BAY RRBP1 110 SF 89 SF POSITIVE AIR
711B RECOVERY BAY RRBP1 110 SF 90 SF POSITIVE AIR
711C RECOVERY BAY RRBP1 110 SF 90 SF POSITIVE AIR
711D RECOVERY BAY RRBP1 110 SF 90 SF POSITIVE AIR
711E RECOVERY BAY RRBP1 110 SF 88 SF POSITIVE AIR
711F RECOVERY BAY RRBP1 110 SF 101 SF POSITIVE AIR
711G RECOVERY BAY RRBP1 110 SF 99 SF POSITIVE AIR
711H RECOVERY BAY RRBP1 110 SF 81 SF POSITIVE AIR
711J RECOVERY BAY RRBP1 110 SF 92 SF POSITIVE AIR
711K RECOVERY BAY RRBP1 110 SF 92 SF POSITIVE AIR
711L RECOVERY BAY RRBP1 110 SF 86 SF POSITIVE AIR
712 MEDICATION MEDP1 100 SF 67 SF NEUTRAL AIR
713 ISOLATION BAY RRIR1 150 SF 118 SF DOUBLE NEG. AIR
714 TOILET TLTU1 60 SF 53 SF NEGATIVE AIR
715 ANTE ROOM RRIR1 45 SF 58 SF NEGATIVE AIR
716 SOILED UTILITY USCL1 80 SF 66 SF DOUBLE NEG. AIR
717 STORAGE - - 65 SF POSITIVE AIR
718 IT CLOSET TETR1 - 114 SF POSITIVE AIR
719 BIOMED COMMUNICATION - - 115 SF POSITIVE AIR
720A CARDIAC OR 3 ORCT1 750 SF 730 SF DOUBLE POS. AIR
720B PUMP ROOM & ABG ORHL1 260 SF 104 SF DOUBLE POS. AIR
720C EQUIPMENT STORAGE SRE01 120 SF 205 SF NEUTRAL AIR
721 CLEAN SUPPLY SRSE1 100 SF 167 SF POSITIVE AIR
722 SCRUB - - 59 SF POSITIVE AIR
723A HYBRID OR 10 ORHY2 900 SF 992 SF DOUBLE POS. AIR
723B CONTROL ROOM ORHC1 220 SF 151 SF NEUTRAL AIR
723C HYBRID STORAGE - - 183 SF NEUTRAL AIR
724 HAC JANC1 40 SF 34 SF DOUBLE NEG. AIR
725 TOILET TLTU1 60 SF 62 SF NEGATIVE AIR
726 GAS STORAGE SRGC1 60 SF 76 SF NEUTRAL AIR
727 STORAGE - - 100 SF NEUTRAL AIR
728 IMAGE EQUIP COMPONENT ROOM - - 116 SF NEUTRAL AIR
728A NEUROSURGERY OR 9 ORNS1 750 SF 683 SF DOUBLE POS. AIR
729 GAS CYLINDERS SRGC1 60 SF 77 SF NEUTRAL AIR
730 SCRUB - - 49 SF POSITIVE AIR
731 NEURO EQUIP - - 219 SF POSITIVE AIR
732 STORAGE - - 107 SF NEUTRAL AIR
ALC-7-1 ALCOVE RCA04 30 SF 21 SF POSITIVE AIR
TOTAL: 61 9476 SF
KEYNOTE LEGEND
2.52 EXISTING METAL STUD WALL WITH GYPSUM BOARD APPLIED. COMPLETE CONSTRUCTION
PER TAGGED PARTITION TYPE.
2.53 EXISTING METAL STUD WALL WITH NO GYPSUM BOARD. COMPLETE WALL CONSTRUCTION
PER TAGGED PARTITION TYPE.
2.65 CONTRACTOR TO PROVIDE CORRECTIONS TO EXISTING STAIR PER STRUCTURAL NARRATIVE
8.13 ALUMINUM DOOR & FRAME
8.50 ALUMINUM FRAMED STOREFRONT
8.94 CONTRACTOR TO CORRECT WALL FRAMING AND REINSTALL EXISTING WINDOW SYSTEM.
8.95 NEW ELEVATOR DOORS. CONTRACTOR TO COORDINATE SIZE AND LOCATION WITH
ELEVATOR MANUFACTURER.
9.87 CLEAN PAINT EXISTING CMU WALL CONSTRUCTION
9.88 CONTRACTOR TO COMPLETE EXISTING METAL STUD WALL ASSEMBLY AND APPLY GYPSUM
BOARD WHERE REQUIRED
13.10 PROVIDE SHIELDING AS REQUIRED. CONTRACTOR TO COORDINATE WITH VA.