48_PJ101 - SEVENTH FLOOR -PLUMBING MEDICAL GAS PLAN.pdf
PDF 571 KB Posted
- Solicitation number
- 36C10F22R0036
View the file
Other files
Show 40 more
Latest 50 of 122 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9 9A 10 12
C
C1
D
E
F
G
G2
H
I
J
K
1" O
3/4" NO
3/4" N
3/4" MA
1 1/2" MV
1" O
3/ 4"
N
1/
2" M
V
1/
2" M
V
1" O
3/4" O
3/4" MA
1" MV
3/4" MV
3/4" MA
3/4" O
3/4" MV
3/4" MA
3/4" O
1" O
3/4" NO
3/4" N
3/4" MA
1 1/2" MV
3/ 4"
N O
1" O
3/ 4"
M A
1/
2" M
V
3/4" NO
ELEC
CLOSET
7F-133
HAC
7F-131
X-RAY
STORAGE
7F-130
STORAGE
7F-129
STORAGE
SCRUB
GAS
CYLINDERS
IMAGE
EQUIP
COMPONENT
ROOM
CONTROL
ROOM
723B
HAC
SCRUB
7F-132
SUB-STER
7F-113c
CARDIAC
OR 4
xx
NEURO
EQUIP
NEUROSURGERY
OR 9
728A
HYBRID OR
723A
SCRUB
HYBRID
STORAGE
723C
CARDIAC
OR 3
720A
STORAGE
GAS
STORAGE
TOILET
CORRIDOR
COR-7-10
CORRIDOR
COR-7-12
CORRIDOR
COR-7-11
CORRIDOR
COR-7-9
CORRIDOR
COR-7-8
BIOMED
COMMUNICATION
SUB-STER
7F-113g
CORRIDOR
COR-7-6
SOILED
UTILITY
7F-153
CORRIDOR
C7 12F
CORRIDOR
COR-7-3
POST-OP
AREA
CLEAN
SUPPLY
MEDICATION
TOILET
STORAGE
SOILED
UTILITY
STORAGE
CLEAN
SUPPLY
EQUIPMENT
STORAGE
720C
IT CLOSET
ELEVATOR
P-12
SUB-STER
7F-113b
HAC
GENERAL
OR 2
7F-122
GENERAL
OR 1
7F-118
STORAGE
7F-121
SCRUB
7F-120
STORAGE
7F-119
SUB-STER
7F-113a
HAC
7F-114
EXIST. ELEC
CLOSET
7F-116a
EXIST. ELEC
CLOSET
7F-116
SOILED
UTILITY
TOILET
MEDICATION
STORAGE
RECOVERY
ISOLATION
BAY
713 CONSULT
ELEVATOR
LOBBY
COR-7-1
ELEVATOR
P-8
ELEVATOR
P-7
ELEVATOR
P-9
ELEVATOR
P-10 STAIR 8
TOILET
701C
TOILET
701B CORRIDOR
COR-7-2
SURGICAL
WAITING
701A
EXIST.
TELECOM
7F100
PUMP
ROOM &
ABG
720B
ALCOVE
ALC-7-1
ANTE ROOM
CORRIDOR
COR-7-4
3/4" WAGD
1/2" N
3/4" MA
1" O3/4" NO
3/ 4"
N O
1" O
3/ 4"
M A
3/4" O
3/4" MA
3/4" MA
3/4" NO
1" O
3/4" NO
1" O
3/4" MA
1 1/2" MV
1/2" MA
3/4" MV
1/2" O
1" WAGD
1/2" NO
1/2" O
1 1/2" MV
1/2" MA
1" N
1" N
1" N
1" N
1" N
2" W
A G
D
2" WAGD
1/
4" W
A G
D
ZVB
ZVB
ZVB-N
ZVB
3" MV
3" M
V
3" MV
ZVB
ZVB-N
1/2" O
1/2" MA
3/4" MV
3/ 4"
M A
3/ 4"
M V3/ 4"
O
3/ 4"
M V
1/2" MA
1/ 2"
O
1" N
1/2" O
1/2" MA
3/4" MV
1 1/2" MV
1" O
3/4" MA
ZVB-N
1/ 2"
O
3/4" MV
1/2" MA
EXIST. OXYGEN UP TO FLOOR ABOVE.
1/ 2"
N
1/2" N
1/ 2"
N
1/2" N
1" N
1/2" N 1/2" N
NOT IN SCOPE
N
RECOVERY &
SURGICAL WAITING
7TH FLOOR KEY PLAN
PHASE-TWO
POST- OP
OPERATING ROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Office Of Construction & Facilities Management Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
OK ARCH REG. NO. CA02295, EXP. 06/30/2023
OK ENGR REG. NO. CA7127, EXP. 06/30/2023
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
HEALTHCARE PLANNER
OCULUS INC.
1 S. MEMORIAL DR., SUITE 1500
ST. LOUIS, MO 63102
(314) 367-6100
SPUR PROJECT NUMBER: 1791.08
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
SEE FRONT COVER SHEET
FOR APPROVAL SIGNATURE
VERTICAL TRANSPORTATION
ENVIRONMENTAL HYGIENIST
TEC-AN, INC.
2517 S. PURDUE AVE.
OKLAHOMA CITY, OK 73128
(405) 681-7076
LERCH BATES
2001 BRYAN ST., SUITE 1930
DALLAS, TX 75201
(972) 294-5221
/2
/2
:5
:4
A
M
PJ101
SEVENTH FLOOR - PLUMBING MEDICAL
GAS PLAN
GH
48 OF 92JRM
100% RFP DOCUMENTS
CONSTRUCT SURGICAL INTENSIVE
CARE UNIT & RENOVATE
OPERATING ROOMS
08/02/2021
635-436
OKLAHOMA CITY VA HEALTHCARE SYSTEM
921 NE 13TH ST, OKLAHOMA CITY, OK 73104
N
1/8" = 1'-0"
SEVENTH FLOOR - PLUMBING MEDICAL GAS PLAN
PLUMBING KEYNOTES
4 CONNECT NEW MEDICAL GAS PIPING TO EXISTING MEDICAL GAS PIPING AT THIS APPROXIMATE LOCATION.
CONTRACTOR TO VERIFY SIZE AND LOCATION.
19 PROVIDE ROUGH-IN OF MEDICAL GAS TO APPROXIMATE BOOM LOCATIONS. TURN DOWN AND CAP FOR FUTURE
CONNECTION.
20 NITROGEN CONTROL PANEL. THE PANEL SHALL HAVE INLET GAUGE, ADJUSTABLE RELIEVING TYPE PRESSURE, AND A REMOTE PIGTAIL FOR REMOTE ROOM OUTLET. REMOTE OUTLET TO BE REGULATED BY ADJUSTABLE PRESSURE
REGULATOR. OUTLETS SHALL HAVE A MALE DISS OUTLET CONNECTION.
24 PROVIDE NEW MEDICAL GAS OUTLETS AT EACH BED. TURN DOWN AND CAP FOR FUTURE CONNECTION.
25 PROVIDE ISOLATION VALVES FOR MEDICAL GAS PIPE OUTSIDE ROOM (TYP.)
26 NEW 2" WASTE ANESTHESIA GAS DISPOSAL UP TO PENTHOUSE ABOVE AT THIS LOCATION. PROVIDE AN OIL FREE CLAW MEDICAL VACUUM IN THE EXISTING PENTHOUSE ABOVE. BASIS OF DESIGN IS BEACONMEDAES MODEL #
VAV03D-060H-D OR SIMILAR.
28 CONNECT NEW MEDGAS PIPE TO EXISTING ZONE VALVE BOX. VERIFY SIZE OF ZONE VALVES BEFORE CONNECTION IS
MADE. FOLLOW ASSE 6010 GUIDELINES FOR ALL MEDICAL GAS INSTALLATION.
33 CONTRACTOR TO INSPECT AND VERIFY EXISTING MED GAS PIPING MEETS VA GUIDE LINES AND NFPA-99 BEFORE ANY
CONNECTIONS ARE MADE.
37 CONTRACTOR TO PERFORM NFPA 99 TESTING REQUIREMENTS FOR ALL NEW AND EXISTING MED-GAS PIPING BEFORE CONNECTING TO THE MAIN. STANDING PRESSURE TEST FOR SUPPLY PIPE OF 20% ABOVE SYSTEM PRESSURE FOR
24HR'S. VACUUM SYSTEM SHALL BE SUBJECT TO NEGATIVE 12" OF WATER FOR 24HR'S.
PLUMBING GENERAL NOTE:
1. THE FINAL SIZING AND ROUTING SHALL BE DONE BY THE DESIGNER OF RECORD.
2. DESIGN BUILD TEAM AND A/E OF RECORD MUST FOLLOW ALL CURRENT VA NATIONAL TIL
STANDARDS, INCLUDING VA NATIONAL CAD STANDARDS, THROUGHOUT DESIGN AND
CONSTRUCTION.
No. REVISION DESCRIPTION DATE