1 2 3 4 5 6 7 8 9 9A 10 12
C
C1
D
E
F
G
G2
H
I
J
K
2" V
3" SS
3" V
3" SS
3" SS
3" SS
3" V
4" SS3" SS
3" V
4" SS
6" ST
2" V
2" V
2" V
2" V2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" SS
4" S
S
4" SS4" SS
2" V
2" V
2" V
2" V
2" V
2" V
ELEC
CLOSET
7F-133
HAC
7F-131
X-RAY
STORAGE
7F-130
STORAGE
7F-129
STORAGE
SCRUB
GAS
CYLINDERS
CONTROL
ROOM
723B
SCRUB
7F-132
SUB-STER
7F-113c
CARDIAC
OR 4
xx
NEURO
EQUIP
NEUROSURGERY
OR 9
728A
HYBRID OR
723A
SCRUB
HYBRID
STORAGE
723C
CARDIAC
OR 3
720A
STORAGE
GAS
STORAGE
TOILET
CORRIDOR
COR-7-10
CORRIDOR
COR-7-12
CORRIDOR
COR-7-11
CORRIDOR
COR-7-8
BIOMED
COMMUNICATION
EXISTING
CLEAN
CORE
7F-113
SUB-STER
7F-113g
SOILED
UTILITY
7F-153
CORRIDOR
C7 12F
CORRIDOR
COR-7-3
POST-OP
AREA
CLEAN
SUPPLY
STORAGE
SOILED
UTILITY
STORAGE
CLEAN
SUPPLY
EQUIPMENT
STORAGE
720C IT CLOSET
ELEVATOR
P-12
SUB-STER
7F-113b
HAC
GENERAL
OR 2
7F-122
GENERAL
OR 1
7F-118
SCRUB
7F-120
STORAGE
7F-119
SUB-STER
7F-113a
HAC
7F-114
EXIST. ELEC
CLOSET
7F-116a
EXIST. ELEC
CLOSET
7F-116
SOILED
UTILITY
TOILET
MEDICATION
STORAGE
RECOVERY
ELEVATOR
LOBBY
COR-7-1
ELEVATOR
P-8
ELEVATOR
P-7
ELEVATOR
P-9
ELEVATOR
P-10 STAIR 8
CORRIDOR
COR-7-2
EXIST.
TELECOM
7F100
PUMP
ROOM &
ABG
720B
CORRIDOR
COR-7-4
ELEC
CLOSET
7F-133
HAC
7F-131
X-RAY
STORAGE
7F-130
STORAGE
7F-129
STORAGE
GAS
CYLINDERS
IMAGE
EQUIP
COMPONENT
ROOM
CONTROL
ROOM
723B
HAC
SCRUB
7F-132
SUB-STER
7F-113c
CARDIAC
OR 4
xx
NEUROSURGERY
OR 9
728A
SCRUB
HYBRID
STORAGE
723C
CARDIAC
OR 3
720A
STORAGE
GAS
STORAGE
CORRIDOR
COR-7-10
CORRIDOR
COR-7-12
CORRIDOR
COR-7-11
CORRIDOR
COR-7-9
CORRIDOR
COR-7-8
BIOMED
COMMUNICATION
EXISTING
CLEAN
CORE
7F-113
SUB-STER
7F-113g
CORRIDOR
COR-7-6
SOILED
UTILITY
7F-153
CORRIDOR
C7 12F
CORRIDOR
COR-7-3
POST-OP
AREA
MEDICATION
TOILET
STORAGE
STORAGE
CLEAN
SUPPLY
EQUIPMENT
STORAGE
720C IT CLOSET
ELEVATOR
P-12
SUB-STER
7F-113b
HAC
GENERAL
OR 2
7F-122
GENERAL
OR 1
7F-118
STORAGE
7F-121
SCRUB
7F-120
STORAGE
7F-119
SUB-STER
7F-113a
HAC
7F-114
EXIST. ELEC
CLOSET
7F-116a
EXIST. ELEC
CLOSET
7F-116
SOILED
UTILITY
TOILET
RECOVERY
ISOLATION
BAY
CONSULT
OR
COUNTER
702A
ELEVATOR
LOBBY
COR-7-1
ELEVATOR
P-8
ELEVATOR
P-7
ELEVATOR
P-9
ELEVATOR
P-10 STAIR 8
TOILET
701C
TOILET
701B
CORRIDOR
COR-7-2
SURGICAL
WAITING
701A
EXIST.
TELECOM
7F100
PUMP
ROOM &
ABG
720B
ANTE ROOM
CORRIDOR
COR-7-4
2" V
3" V
4" ST
4" ST 4" ST
4" ST
6" ST
6" S
T
6" ST
4" S
T
4" SS-UF
(E) 4"
VENT
STACK
(E) 6" VENT STACK
(E) 4"
VENT
STACK
(E) 6" VENT STACK
(E) 4"
VENT
STACK
4" ST
6" ST
(E) 4"
VENT
STACK
4" SS 4" SS
3" SS 3" SS
2" SS
4" S
S
4" S
S
4" SS
2" SS
4" SS 4" SS
2" S
S 2"
S S
2" SS
2" S
S
2" SS
4" SS
4" S
S 4" S
S
5 6
4" S
S
5 6
2" SS4" SS
4" S
S
4" S
S
P-418
P-418
P-103
P-103
P-418 P-418
P-418
P-502
P-103
10 P-103P-103
4" S
S
4" SS
4" S
S
P-608
4" SS
P-418
EXIST. 4" WASTE
STACK
EXIST. WASTE STACK
2" SS
2" V
2" S
S 5
(E) 4"
WASTE
STACK
2" V
EXIST. 2" V UP
EXIST. 2" V
FR. BLW.
2" SS
4" S
S
P-528
2" SS-UF
2" S
S -U
F
4" SS-UF
P-505
P-505
P-708
P-505
P-708
PATIENT
BAY
704G
PATIENT
BAY
704F
PATIENT
BAY
704E
PATIENT
BAY
704C
PATIENT
BAY
704A
PATIENT
BAY
704B
PATIENT
BAY
704J
PATIENT
BAY
704H
RECOVERY
BAY
711A
RECOVERY
BAY
711B
RECOVERY
BAY
711C
RECOVERY
BAY
711D
FD-C
FD-C
2" SS
NOT IN SCOPE
P-413
P-413
P-413
P-413
P-528
P-528
P-413
P-418
P-413
P-413
2" S
S
4" SS
RECOVERY
BAY
711L
RECOVERY
BAY
711K
RECOVERY
BAY
711J
RECOVERY
BAY
711H
RECOVERY
BAY
711G
RECOVERY
BAY
711F
RECOVERY
BAY
711E
NURSE
STATION
711M
EXISTING TO REMAIN.
N
RECOVERY &
SURGICAL WAITING
7TH FLOOR KEY PLAN
PHASE-TWO
POST- OP
OPERATING ROOMS
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Office Of Construction & Facilities Management Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
OK ARCH REG. NO. CA02295, EXP. 06/30/2023
OK ENGR REG. NO. CA7127, EXP. 06/30/2023
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
HEALTHCARE PLANNER
OCULUS INC.
1 S. MEMORIAL DR., SUITE 1500
ST. LOUIS, MO 63102
(314) 367-6100
SPUR PROJECT NUMBER: 1791.08
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
SEE FRONT COVER SHEET
FOR APPROVAL SIGNATURE
VERTICAL TRANSPORTATION
ENVIRONMENTAL HYGIENIST
TEC-AN, INC.
2517 S. PURDUE AVE.
OKLAHOMA CITY, OK 73128
(405) 681-7076
LERCH BATES
2001 BRYAN ST., SUITE 1930
DALLAS, TX 75201
(972) 294-5221
/2
/2
:5
:1
A
M
PL101
SEVENTH FLOOR - PLUMBING WASTE
AND VENT PLAN
GH
44 OF 92JRM
100% RFP DOCUMENTS
CONSTRUCT SURGICAL INTENSIVE
CARE UNIT & RENOVATE
OPERATING ROOMS
08/02/2021
635-436
OKLAHOMA CITY VA HEALTHCARE SYSTEM
921 NE 13TH ST, OKLAHOMA CITY, OK 73104
N
1/8" = 1'-0"
SEVENTH FLOOR - PLUMBING WASTE AND VENT PLAN
PLUMBING KEYNOTES
1 CONNECT NEW SANITARY TO EXISTING SANITARY SEWER AT THIS APPROXIMATE LOCATION.
CONTRACTOR TO VERIFY SIZE AND LOCATION.
2 CONNECT NEW VENT TO EXISTING VENT PIPE AT THIS APPROXIMATE LOCATION. CONTRACTOR TO
VERIFY SIZE AND LOCATION.
5 2" WASTE FROM ABOVE.
6 4" WASTE FROM ABOVE.
10 CONNECT FIXTURE TO EXISTING ROUGH-IN. CONTRACTOR TO VERIFY CONDITION OF PIPE BEFORE
CONNECTION IS MADE.
13 4" WASTE DOWN/ 2" VENT UP.
14 ROUTE SANITARY SEWER ABOVE FLOOR WITH MINIMUM SLOPE.
21 EXISTING ROOF DRAIN FROM ABOVE.
29 2" VENT UP FROM FIXTURE.
32 DRAIN PIPE ROUTED IN SURGICAL SUITE SHALL BE DOUBLE CONTAINMENT TO OUTSIDE OF SURGICAL
SUITE.
34 PLUMBING FIXTURES FURNISHED BY OWNER. CONTRACTOR TO VERIFY CONDITION OF FIXTURE BEFORE
INSTALLATION.
36 ROUTE SANITARY SEWER BELOW FLOOR WITH MINIMUM SLOPE.
38 2" WASTE DOWN/ 1-1/2" VENT UP FROM FIXTURE.
PLUMBING GENERAL NOTE:
1. THE FINAL SIZING AND ROUTING SHALL BE DONE BY THE DESIGNER OF RECORD.
2. DESIGN BUILD TEAM AND A/E OF RECORD MUST FOLLOW ALL CURRENT VA NATIONAL TIL
STANDARDS, INCLUDING VA NATIONAL CAD STANDARDS, THROUGHOUT DESIGN AND
CONSTRUCTION.
No. REVISION DESCRIPTION DATE