66_M-502 - MECHANICAL DETAILS.pdf

PDF 200 KB Posted

Attached to
Y1AZ--Design Build, Construct SICU and Renovate Operating Rooms
Solicitation number
36C10F22R0036
Issued by

View the file

Other files

File Type Posted
Award Notice 36C10F24C0002.pdf PDF
36C10F22R0036 0004.pdf PDF
36C10F22R0036 0003.pdf PDF
36C10F22R0036 0002.pdf PDF
36C10F22R0036 0001.pdf PDF
36C10F22R0036.pdf PDF
45_PL102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
40_PPD101 - SEVENTH FLOOR -PLUMBING DOMESTIC WATER DEMOLITION PLAN.pdf PDF
61_MHP100 - MECHANICAL DUCT and PIPING PLAN -ROOF LEVEL.pdf PDF
17_AF702 - FINISH PLAN -EIGHTH FLOOR.pdf PDF
07_ELEVATOR NARRATIVE.pdf PDF
52_MDH100 - MECHANICAL DUCT DEMOLITION PLAN -SEVENTH FLOOR.pdf PDF
100 percent RFP PLUMBING CALCS.pdf PDF
48_PJ101 - SEVENTH FLOOR -PLUMBING MEDICAL GAS PLAN.pdf PDF
55_MDP100 - MECHANICAL PIPING DEMOLTION PLAN -SEVENTH FLOOR.pdf PDF
44_PL101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
24_QH105 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 1.pdf PDF
04_FIRE PROTECTION.pdf PDF
OR-SICU 100 percent Digital Material Board.pdf PDF
28_QH109 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
27_QH108 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
84_EY301 - SEVENTH FLOOR ELECTRICAL LOW VOLTAGE PLAN.pdf PDF
4_GI102 - LIFE SAFETY PLAN -EIGHTH FLOOR.pdf PDF
86_EP401 - ELECTRICAL LIGHTNING PROTECTION PLAN.pdf PDF
21_QH102 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 2.pdf PDF
13_AE115 - DIMENSION PLAN -EIGHTH FLOOR.pdf PDF
90_EP504 - ELECTRICAL DETAILS.pdf PDF
88_EP502 - SCHEDULES AND DETAILS.pdf PDF
26_QH107 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 3 and INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
39_PLD102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
9_AE111 - REFERENCE PLAN -SEVENTH FLOOR.pdf PDF
12_AE114 - DIMENSION PLAN -SEVENTH FLOOR.pdf PDF
14_AE211 - REFLECTED CEILING PLAN -SEVENTH FLOOR.pdf PDF
01_Mold Report.pdf PDF
Floor 7 Inventory OKC VAMC.pdf PDF
71_M-704 - MECHANICAL CONTROLS.pdf PDF
30_FA001 - FIRE ALARM_MASS NOTIFICATION GENERAL NOTES.pdf PDF
56_MDP101 - MECHANICAL PIPING DEMOLTION PLAN -EIGHTH FLOOR.pdf PDF
02_ARCHITECTURAL.pdf PDF
1_GI000 - COVER SHEET.pdf PDF
50_P-600 - PLUMBING SCHEDULES.pdf PDF
82_EL201 - SEVENTH FLOOR ELECTRICAL LIGHTING PLAN.pdf PDF
60_MH103 - MECHANICAL ZONING and CONTROLS PLAN -EIGHTH FLOOR.pdf PDF
06_ELECTRICAL NARRATIVE.pdf PDF
02_STRUCTURAL NARRATIVE.pdf PDF
20_QH101 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 1.pdf PDF
38_PLD101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
Floor 8 Inventory OKC VAMC.pdf PDF
63_MP101 - MECHANICAL HVAC PIPING PLAN -EIGHTH FLOOR.pdf PDF
03_EQUIPMENT.pdf PDF
Show 40 more

Latest 50 of 122 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AIR FLOW

MV

MV

MV

MV

NOTES:

1. INSTALL CONTROL VALVE BETWEEN UNIONS OR FLANGES.

2. PROVIDE CONCENTRIC REDUCERS BOTH SIDES OF CONTROL VALVE AS REQUIRED.

3. REPLACE UNION/FLANGE SET WITH A FLEXIBLE PIPE CONNECTOR WHERE EQUIPMENT IS

SUPPORTED OR SUSPENDED BY SPRING ISOLATORS.

4. ARRANGEMENT SHOWN FOR FULL FLOW THROUGH COIL ON FAILURE.

COMBINATION UNION

AND PT PORT (TYP)

COIL

COIL DRAIN WITH CAP AT

LOWEST POINT OF COIL (TYP)

PRESSURE

GAUGE (TYP)

THERMOMETER

(TYP)

MANUAL AIR VENT

(TYP)

2-WAY PRESSURE

INDEPENDENT CONTROL

VALVE

SEE NOTE 2

UNION (TYP)

ISOLATION VALVE (TYP)

INSTALL MANUAL AIR VENT AT HIGH

POINT WHEN TAPPED INTO TO OF

MAINS. USE A PIPE STUB WITH MIN

HEIGHT OF 4 PIPE DIAMETERS (TYP)

CONNECT TO SUPPLY AND RETURN

MAINS AS SHOWN ON PLAN

RETURN PIPING MAIN

SUPPLY PIPING MAIN

SEE PLAN FOR PIPE SIZES

DRAW THRU

BLOW THRU

X

2X

UNIT TYPE A B

WHERE X = STATIC PRESSURE IN PAN

CLEAN OUT

FLOOR SINK

NOTES:

1. CPVC PIPE MAY BE USED ONLY IF APPROVED BY LOCAL VA AND IS INDOORS

AND DOES NOT PASS THROUGH RATED BARRIERS.

2. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS ARE TO BE

CONNECTED.

PITCH DOWN

TOWARD DRAIN

DRAIN LINE SHALL BE AT LEAST THE SAME SIZE

AS THE NIPPLE ON THE DRAIN PAN PIPING

SHALL BE RIGID COPPER TYPE L OR TYPE M

UNLESS NOTE BELOW IS MET

DRAIN

PAN

DIELECTRIC

FITTING

1" MINIMUM

2" PLUS X

B A

1"

AIR FLOW

MV

MV

PRESSURE INDEPENDENT

CONTROL VALVE

COMBINATION UNION/BALL

VALVE WITH TEST PLUG AND

UNION END

INSTALL MANUAL AIR VENT AT HIGH

POINT WHEN TAPPED INTO TOP OF

MAINS. USE A PIPE STUB WITH MIN.

HEIGHT OF 4 PIPE DIAMETERS (TYP).

CONNECT TO SUPPLY AND RETURN

MAIN AS SHOWN ON PLANS.

RETURN PIPING MAIN

SUPPLY PIPING MAIN

SEE PLAN FOR PIPE SIZESSTAINLESS STEEL

BRAIDED HOSE

COMBINATION BALL VALVE

ISOLATION/STRAINER WITH P/T TEST

PLUG, BLOW DOWN DRAIN VALVE,

MANUAL AIR VENT, AND UNION END.

COIL

HHS

HHR

DP

OPTION "A"

OPTION "B"

ROOF DECK

ABS CURB CAP

EPDM RUBBER CAP

INSULATION

1" CLEAR OPENING AROUND

PIPE TO ALLOW FOR PIPE

MOVEMENT

INSULATED ROOF CURB

WITH 26 GA. GALVANIZED

COUNTER FLASHING

ACRYLIC COATED ABS

RUB REINFORCED

PLASTIC CURB COVER

EPDM PROTECTIVE

RUBBER CAP

STAINLESS STEEL

CLAMP

SINGLE OR MULTIPLE

PENETRATIONS

PIPE PENETRATION(S)

PER PLAN

PIPE

INSULATION

SCREW CAP

PIGTAIL OR VIBRATION

ISOLATOR

1/4" PIPE, GUAGE COCK

AND PIPEFITINGS

CONTINOUS

WELD

WELD-O-LET

NOT TO SCALE

TYPICAL AHU COIL PIPING - 2-WAY (PIC) VALVE1NOT TO SCALE

AIR HANDLING UNIT DRAIN TRAP3 NOT TO SCALE

TYPICAL HYDRONIC COIL PIPING - 2-WAY (PIC) VALVE2NOT TO SCALE

PIPE ROOF PENETRATION CURB4

NOT TO SCALE

TYPICAL GAUGE OUTLET DETAIL5

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Office Of Construction & Facilities Management Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

OK ARCH REG. NO. CA02295, EXP. 06/30/2023

OK ENGR REG. NO. CA7127, EXP. 06/30/2023

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

HEALTHCARE PLANNER

OCULUS INC.

1 S. MEMORIAL DR., SUITE 1500

ST. LOUIS, MO 63102

(314) 367-6100

SPUR PROJECT NUMBER: 1791.08

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

SEE FRONT COVER SHEET

FOR APPROVAL SIGNATURE

VERTICAL TRANSPORTATION

ENVIRONMENTAL HYGIENIST

TEC-AN, INC.

2517 S. PURDUE AVE.

OKLAHOMA CITY, OK 73128

(405) 681-7076

LERCH BATES

2001 BRYAN ST., SUITE 1930

DALLAS, TX 75201

(972) 294-5221

/2

/2

:2 :0

P

M

M-502

MECHANICAL DETAILS

JLF

66 OF 92JRM

100% RFP DOCUMENTS

CONSTRUCT SURGICAL INTENSIVE

CARE UNIT & RENOVATE

OPERATING ROOMS

08/02/2021

635-436

OKLAHOMA CITY VA HEALTHCARE SYSTEM

921 NE 13TH ST, OKLAHOMA CITY, OK 73104

No. REVISION DESCRIPTION DATE

File details come from the government source that posted it. Updated .