6_AD012 - DEMOLITION PLAN -EIGHTH FLOOR.pdf
PDF 422 KB Posted
- Solicitation number
- 36C10F22R0036
View the file
Other files
Show 40 more
Latest 50 of 122 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FD FD
FD FD
1. EXISTING CONDITIONS ARE BASED ON INFORMATION OBTAINED FROM EXISTING DRAWINGS
AND FIELD SURVEY, AND SHALL NOT BE CONSTRUED "AS BUILT." THE CONTRACTOR SHALL
FIELD VERIFY EXISTING CONDITIONS PRIOR TO ONSET OF CONSTRUCTION.
2. THE CONTRACTOR SHALL COORDINATE WITH OWNER FOR ALL EXISTING EQUIPMENT AND
FURNITURE ITEMS THAT ARE TO BE SALVAGED OR REINSTALLED PRIOR TO THE
COMMENCEMENT OF DEMOLITION.
3. ALL WALL PARTITIONS SHOWN DASHED ARE TO BE REMOVED. THE CONTRACTOR SHALL
PATCH ALL PARTITIONS, CEILINGS, AND FLOORS AFFECTED BY DEMOLITION TO MATCH
ADJACENT CONSTRUCTION.
4. ALL DOORS SHOWN DASHED ARE TO BE REMOVED ALL ASSOCIATED DOOR FRAMES TO BE
REMOVED UNLESS NOTED.
5. THE OWNER SHALL HAVE THE FIRST RIGHT TO ALL MATERIALS AND EQUIPMENT THAT ARE
REMOVED BY THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY WHEN REMOVAL OF ITEMS
ARE TO BE RETAINED BY THE OWNER AT THE PRE CONSTRUCTION MEETING.
6. CLEAN AND PREPARE ALL SURFACES AFFECTED BY DEMOLITION TO PRODUCE FLAT, EVEN
SURFACE TO RECEIVE NEW FINISHES.
7. CONTRACTOR SHALL PROTECT ALL EXISTING BUILDING SURFACES TO REMAIN.
8. PATCH AND REPAIR SURFACES AND FINISHES AFFECTED BY THE DEMOLITION OR THE
REMOVAL OF CONSTRUCTION AS NECESSARY TO MAINTAIN THE FINISH QUALITY OF NEW
SPACE.
9. FILL ALL DUCT AND PIPE PENETRATIONS IN AREA OF DEMOLITION WITH 1 HOUR RATED
ASSEMBLY. FILL WITH 2 - HOUR RATED ASSEMBLY ADJACENT AND WITHIN 2-HOUR
CONSTRUCTION.
10. COORDINATE SCHEDULING OF ANY DEMOLITION/PLACEMENT OF RATED WALL CONSTRUCTION
WITH FIRE/LIFE SAFETY A.H.J.
11. VERIFY CONDITION OF EXISTING CONSTRUCTION TO REMAIN. PROVIDE BOARD AND FINISH
WHERE REQUIRED.
12. EXISTING SPRAY-ON FIREPROOFING TO BE PROTECTED DURING DEMOLITION AND NEW
CONSTRUCTION. NEW FIRE PROOFING TO BE APPLIED BY CONTRACTOR AT NO EXPENSE IF
DAMAGED DURING CONSTRUCTION
13. REMOVE ALL EXISTING GYPSUM BOARD WITHIN SCOPE OF RENOVATED AREA AND PROVIDE
NEW GYPSUM BOARD PER DEFINED PARTITION TYPES.
GENERAL DEMOLITION FLOOR PLAN NOTES
1 2 3 4 5 6 7 8 9 10 11 11a
E
F
G
H
I
J
K
9A
G2
2.16
2.16
2.16
2.16
2.16
2.16
2.162.16
2.16 2.16
2.16
2.16 2.16
2.16
2.16
2.16
2.16 2.16 2.16 2.16 2.16 2.16
2.16 2.16 2.16 2.162.16
2.16 2.16 2.16 2.16
2.162.16 2.16 2.16 2.162.16 2.162.16 2.162.16
2.16 2.16
2.16
2.16
2.16
2.16
2.16
2.182.18
2.16
2.16 2.16 2.16 2.16 2.16 2.16
2.16
2.16
2.16
2.16
2.16
2.16
2.16
2.16
2.16
2.162.16
2.162.16
2.162.16
2.16
2.16
2.16
2.162.16
2.162.16 2.162.16
2.16
2.16
2.162.16
2.162.16
2.16
2.16 2.162.16
2.16
2.162.16
2.162.16
2.16
2.162.162.16
2.16
2.16
2.16
2.15
ISOLATION
ICU PAT. RM.
8F-111
ANTE RM
8F-110
ICU PAT. RM.
8F-109
ICU PAT. RM.
8F-108
ICU PAT. RM.
8F-107
ICU PAT. RM.
8F-106
ICU PAT. RM.
8F-105
ICU PAT. RM.
8F-104
ICU PAT. RM.
8F-103
ICU PAT. RM.
8F-102
WOMEN'S
8F-101
MEN'S
8F-100
CORRIDOR
C8-5
CORRIDOR
C8-6
CORRIDOR
C8-8
CORRIDOR
C8-7
CORRIDOR
C8-13
CORRIDOR
C8-10
CORRIDOR
C8-3
CORRIDOR
C8-1
ICU PAT. RM.
8F-112
ICU PAT. RM.
8F-113
ICU PAT. RM.
8F-114
TEAM ROOM
8F-115
ICU PAT. RM.
8F-117
ICU PAT. RM.
8F-118
ICU PAT. RM.
8F-119
ICU PAT. RM.
8F-120
NURSE
STATION
8F-148
MEDS
8F-147
CORRIDOR
C8-9
SIGNAL
CLOS.
8F-147
CLEAN
SUPPLIES
8F-147
H.A.C.
8F-144
SOILED
UTILITY
8F-139
CLEAN
UTILITY
8F-140
ELEC.
8F-135
NURSE'S
STATION
8F-130
ICU PAT. RM.
8F-121
ICU PAT. RM.
8F-122
ELEVATOR
P-8
ELEVATOR
P-7
STAFF
LOUNGE
8F-116
NOURISHMENT
8F-146
ELEVATOR
P-12
ELEVATOR
LOBBY
C8-11
GAS
8F-138
GAS
8F-137
TRASH
8F-136
'-9
F
V
7'-3 1/2" F.V.
7'-3 1/2" F.V.
'-1
/2
F
.V
4' -9
F
.V
9'-7 1/2"
'-4
/2
1' -5
/2
2'-2" 1' -1
/2
1' -5
/2
2'-1"
1' -1
/2
2'-1"
3'-7"
4' -4
5'
-8
1' -0
1'
-6
4' -4
1/ 2"
4'-4 1/2" 3'-4 1/2"
1'-10 1/2" 7'-9" 7'-3" 1'-7 1/2" 1'-6" 12'-1 1/2"
7'-10 1/2"
2' -2
/2
'-5
12'-2" FV
2.512.51
2.512.51 2.512.51
4'-0" 2'-1" 4'-0" 5'-4"
2.542.54
2.55
STAIR 8
STAIR 10
2.25
2.562.56 2.562.56 2.562.56 2.562.56 2.562.56
2.562.56 2.56
2.56 2.562.56
2.562.56
2.56 2.562.562.56
ELEVATOR
EQUIPMENT
ROOM
2.60
2.60 2.60
2.60
2.60
2.272.272.272.27
2.27
2.272.27
2.27
2.27
2.27
2.27
2.272.27
2.272.27
2.27
2.27
2.612.61
2.61
2.612.61
2.61
2.61
2.61
2.61
2.61
2.61
2.61
2.612.61
2.16
2.612.61 2.612.61 2.612.61 2.61
2.16
2.61 2.612.61
2.16
2.61
2.16
2.612.61
2.61
2.642.642.64 2.642.642.64
2.642.642.642.642.642.642.642.642.642.64
2.64
2.64
2.64
2.64
2.64
2.64
2.64 2.64
2.64 2.64
2.64
2.66
2.66
2.66
2.66
2.66 2.66
2.66 2.66 2.66 2.66 2.66
2.66
2.66 2.66 2.66
2.66
2.66
2.66
2.66 2.662.66
2.66
2.662.66
2.66
2.66 2.66
2.66
2.66
2.66
2.66
2.66
7TH FLOOR ROOF
N
8TH FLOOR SICU
8TH FLOOR KEY PLAN
EXISTING WALL CONSTRUCTION TO BE
DEMOLISHED IN ITS ENTIRETY
EXISTING DOOR AND FRAME TO BE
DEMOLISHED IN THEIR ENTIRETY
AREA OF NO WORK
EXISTING WALLS TO REMAIN
DEMOLITION PLAN LEGEND
EXISTING WINDOW AND FRAME TO BE
DEMOLISHED IN THEIR ENTIRETY
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS:
Drawing #
VA Office Of Construction & Facilities Management Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
OK ARCH REG. NO. CA02295, EXP. 06/30/2023
OK ENGR REG. NO. CA7127, EXP. 06/30/2023
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FULLY SPRINKLERED
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
HEALTHCARE PLANNER
OCULUS INC.
1 S. MEMORIAL DR., SUITE 1500
ST. LOUIS, MO 63102
(314) 367-6100
SPUR PROJECT NUMBER: 1791.08
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
SEE FRONT COVER SHEET
FOR APPROVAL SIGNATURE
VERTICAL TRANSPORTATION
ENVIRONMENTAL HYGIENIST
TEC-AN, INC.
2517 S. PURDUE AVE.
OKLAHOMA CITY, OK 73128
(405) 681-7076
LERCH BATES
2001 BRYAN ST., SUITE 1930
DALLAS, TX 75201
(972) 294-5221
/2
/2
:1 :5
P
M
AD012
DEMOLITION PLAN - EIGHTH FLOOR
ZDL
6 OF 92JNK
100% RFP DOCUMENTS
CONSTRUCT SURGICAL INTENSIVE
CARE UNIT & RENOVATE
OPERATING ROOMS
08/02/2021
635-436
OKLAHOMA CITY VA HEALTHCARE SYSTEM
921 NE 13TH ST, OKLAHOMA CITY, OK 73104
N
1/8" = 1'-0"
EIGHTH FLOOR DEMOLITION PLAN
KEYNOTE LEGEND
2.15 DEMOLISH EXISTING MECHANICAL EQUIPMENT AND DUCTWORK TO EXTENT INDICATED.
REFERENCE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
2.16 DEMOLISH EXISTING WALL CONSTRUCTION TO EXTENT INDICATED
2.18 DEMOLISH EXISTING FLOORING IN ITS ENTIRETY; CLEAN & PREPARE SUB-FLOOR SURFACE
FOR NEW FLOORING PER RENOVATION PLANS.
2.25 DEMOLISH EXISTING MOP SINK - REFERENCE PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION
2.27 REMOVE AND RETAIN EXISTING DOOR AND FRAME - SALVAGED DOOR AND FRAME TO BE
RETURNED TO VA
2.51 EXISTING FLOOR TO BE LEVELED DOWN TO EXISTING CONCRETE SLAB - SLAB TO REMAIN
FREE OF DEBRIS, ADHESIVES, MORTAR, GROUT, OR ANY OTHER MATERIAL
2.54 EXISTING EQUIPMENT TO BE RELOCATED TO 9TH FLOOR PENTHOUSE ABOVE. CONTRACTOR
TO COORDINATE RELOCATION WITH VA.
2.55 EXISTING METAL STAIR AND LANDING TO BE DEMOLISHED.
2.56 EXISTING WINDOW BLINDS TO BE REMOVED.
2.60 DEMOLISH PORTION OF EXISTING WALL FOR INSTALLATION OF NEW WINDOW TO MATCH
EXISTING ADJACENT WINDOW SYSTEM.
2.61 REMOVE EXISTING GYPSUM BOARD AND INSULATION
2.64 REMOVE EXISTING WINDOW SYSTEM AND SALVAGE FOR REINSTALLATION.
2.66 CONTRACTOR TO CONFIRM AND PRESERVE EXISTING 1 HOUR FIRE PROOFING AT ALL
COLUMNS.
No. REVISION DESCRIPTION DATE