57_MH100 - MECHANICAL HVAC DUCT PLAN -SEVENTH FLOOR.pdf

PDF 510 KB Posted

Attached to
Y1AZ--Design Build, Construct SICU and Renovate Operating Rooms
Solicitation number
36C10F22R0036
Issued by

View the file

Other files

File Type Posted
Award Notice 36C10F24C0002.pdf PDF
36C10F22R0036 0004.pdf PDF
36C10F22R0036 0003.pdf PDF
36C10F22R0036 0002.pdf PDF
36C10F22R0036 0001.pdf PDF
36C10F22R0036.pdf PDF
45_PL102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
40_PPD101 - SEVENTH FLOOR -PLUMBING DOMESTIC WATER DEMOLITION PLAN.pdf PDF
61_MHP100 - MECHANICAL DUCT and PIPING PLAN -ROOF LEVEL.pdf PDF
17_AF702 - FINISH PLAN -EIGHTH FLOOR.pdf PDF
07_ELEVATOR NARRATIVE.pdf PDF
52_MDH100 - MECHANICAL DUCT DEMOLITION PLAN -SEVENTH FLOOR.pdf PDF
100 percent RFP PLUMBING CALCS.pdf PDF
48_PJ101 - SEVENTH FLOOR -PLUMBING MEDICAL GAS PLAN.pdf PDF
55_MDP100 - MECHANICAL PIPING DEMOLTION PLAN -SEVENTH FLOOR.pdf PDF
44_PL101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
24_QH105 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 1.pdf PDF
04_FIRE PROTECTION.pdf PDF
OR-SICU 100 percent Digital Material Board.pdf PDF
28_QH109 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
27_QH108 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
84_EY301 - SEVENTH FLOOR ELECTRICAL LOW VOLTAGE PLAN.pdf PDF
4_GI102 - LIFE SAFETY PLAN -EIGHTH FLOOR.pdf PDF
86_EP401 - ELECTRICAL LIGHTNING PROTECTION PLAN.pdf PDF
21_QH102 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 2.pdf PDF
13_AE115 - DIMENSION PLAN -EIGHTH FLOOR.pdf PDF
90_EP504 - ELECTRICAL DETAILS.pdf PDF
88_EP502 - SCHEDULES AND DETAILS.pdf PDF
26_QH107 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 3 and INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
39_PLD102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
9_AE111 - REFERENCE PLAN -SEVENTH FLOOR.pdf PDF
12_AE114 - DIMENSION PLAN -SEVENTH FLOOR.pdf PDF
14_AE211 - REFLECTED CEILING PLAN -SEVENTH FLOOR.pdf PDF
01_Mold Report.pdf PDF
Floor 7 Inventory OKC VAMC.pdf PDF
71_M-704 - MECHANICAL CONTROLS.pdf PDF
30_FA001 - FIRE ALARM_MASS NOTIFICATION GENERAL NOTES.pdf PDF
56_MDP101 - MECHANICAL PIPING DEMOLTION PLAN -EIGHTH FLOOR.pdf PDF
02_ARCHITECTURAL.pdf PDF
1_GI000 - COVER SHEET.pdf PDF
50_P-600 - PLUMBING SCHEDULES.pdf PDF
82_EL201 - SEVENTH FLOOR ELECTRICAL LIGHTING PLAN.pdf PDF
66_M-502 - MECHANICAL DETAILS.pdf PDF
60_MH103 - MECHANICAL ZONING and CONTROLS PLAN -EIGHTH FLOOR.pdf PDF
06_ELECTRICAL NARRATIVE.pdf PDF
02_STRUCTURAL NARRATIVE.pdf PDF
20_QH101 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 1.pdf PDF
38_PLD101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
Floor 8 Inventory OKC VAMC.pdf PDF
63_MP101 - MECHANICAL HVAC PIPING PLAN -EIGHTH FLOOR.pdf PDF
Show 40 more

Latest 50 of 122 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N

RECOVERY &

SURGICAL WAITING

7TH FLOOR KEY PLAN

PHASE-TWO

POST- OP

OPERATING ROOMS

K

J

I

H

G2

G

F

E

D

C1

C

21 3 4 5 6 7 8 9 9A 10 11 11a 12

38"x16" SA

VAV-7-15

34"x14" SA

10"x10" SA

VAV-7-13

"x

S A

VAV-7-11

10"x12" SA

10"x12" RA

"x

R A

8"x6" RA

26"x14" RA

12"x12" RA

10"x10" RA 10"ø SA

VAV-7-12

9"ø SA

VAV-7-10

8"ø SA

12"ø SA

9"ø SA

10"x12" SA

52"x16" SA

34"x18" RA

14"x14" SA 12"x12" SAVAV-7-8

"x

S A

12"ø SA

VAV-7-9

10"x10" SA

VAV-7-14

10"x10" SA

"x

S A

22"x12" SA

VAV-7-4

14"ø SA

12"x24" SA

10"x24" SA

20"x12" EA

8"x8" SA

32"x18" RA

24"x16" SA

52"x16" SA

14"x10" SA

14"x10" SA

16"x12" SA

"x

R A

"x

R A

30"x16" RA

12"x12" SA

8"x18" SA

"x

S A

"x

R A

"x

R A

"x

R A

VAV42R-1

10"x12" SA

VAV-7-1

5"ø SA

12"x12" EA

10"x26" SA

VAV-7-2

10"x10" EA 6"x6" EA

8"x20" SA

VAV-7-3

36"x16" SA

10"x10" EA

20"x16" RA

VAV-7-7

VAV-7-6

VAV-7-5

"x

S A

10"ø SA

26"x8" SA

26"x8" SA

12"ø SA

12"ø SA

36"x20" SA

18"x12" RA

18"x12" RA

8"ø SA

"x

S A

10"ø SA

VAV34-2

VAV34-1

10"ø SA

10"ø SA

VAV-7-18

6"ø SA

44"x18" SA

7"ø SA

12"ø SA

14"ø SA

9"ø SA

7"ø SA

VAV-X

8"ø SA

9"ø SA

VAV-X

VAV-7-16

VAV-X

VAV-X

VAV-X

9"ø SA

VAV-X

5"ø SA

16"x10" RA

"x

E A

24"x12" RA

36"x12" RA

"x

R A

10"x6" RA

12"x12" RA

16"x12" SA

14"x12" SA

12"x12" RA

"x

R A

"x

R A

"x

S A

12"x6" SA

12"x10" SA

24"x10" SA

VAV-X

20"x12" RA 12"x12" RA

8" x1

2" S

A

"x

S A

36"x20" RA

8"x6" RA

VAV42R-2

VAV42-1

ELEVATOR-2

P-12-2

STORAGE

STAIR 10

NEURO EQUIP

HYBRID STORAGE

723C

ELEVATOR-2

P-8-2

ELEVATOR-2

P-7-2

EXIST. TELECOM

ELEVATOR-1

P-9-1

SCRUB

CORRIDOR

COR-7-3

CORRIDOR

COR-7-2

STAIR 8

CORRIDOR

COR-7-9

STORAGE

HYBRID OR 10

723A

NEUROSURGERY OR 9

728A

GAS CYLINDERS

IMAGE EQUIP

COMPONENT ROOM

CONTROL ROOM

723B

HAC

TOILET

701B

ALCOVE

ALC-7-1

CORRIDOR

COR-7-10

STORAGE

MEDICATION

TOILET

CLEAN SUPPLY

MEDICATION

TOILET

TOILET

701C

CONSULT

SURGICAL WAITING-1

701A-1

ISOLATION BAY

SOILED UTILITY

CARDIAC OR 3

720A

SCRUB

CLEAN SUPPLY

GAS STORAGE

TOILET

BIOMED

COMMUNICATION

PUMP ROOM & ABG

720B

EQUIPMENT STORAGE

720C

CORRIDOR

COR-7-8

IT CLOSET

ELEVATOR LOBBY

COR-7-1

ANTE ROOM

STORAGE

POST-OP AREA

STORAGE

CORRIDOR

COR-7-4

SOILED UTILITY

CORRIDOR

COR-7-5

RECOVERY

CORRIDOR-2

COR-7-12-2

ELEVATOR-1

P-10-1

20" X 12" EA

UP TO ROOF

3 3 3 3 3 3 3 3 3

52" X 16" SA

DOWN TO

FLOOR BELOW

VAV34R-1

10"ø SA

VAV34R-2

26"x12" RA 3

3 9

34" X 18" RA

DOWN TO

FLOOR BELOW

10"x8" EA

VAV-X

14"x8" EA

NOT IN SCOPE

18"x12" RA

8"x8" RA

24"x12" SA

VAV-X

9"ø SA

9"ø SA

10"ø SA

16"x10" EA UP

TO ROOF

12"ø SA

8"x6" RA

"x

R A

8"ø SA

14"x14" SA

8"x8" EA

7"ø SA

10"ø SA

10"ø SA

(2) 14"X8" EA

UP TO ROOF

8"x8" RA

8"ø SA

60"x20" RA UP

TO ROOF

50"x24" SA

10"ø SA

10"ø SA

10"ø SA

"x

S A

"x

S A

24"x24" SA

VAV-7-17

11 9

VAV-X

16"x10" SA

6"x6" EA

6"ø SA

6"x6" TRANFER

DUCT

6"x6" EA UP TO

ROOF

DOC. STORAGE

702B OR COUNTER

702A

23 24

"x

R A

60"x20" RA

28"x14" SA

28"x14" SA

28"x14" SA

24"x20" RA

36"x20" SA

VAV-7-20

VAV-7-19

1. EXISTING CONDITIONS ARE BASED ON INFORMATION OBTAINED FROM EXISTING DRAWINGS AND

FIELD SURVEY, AND SHALL NOT BE CONSTRUED "AS BUILT." THE CONTRACTOR SHALL FIELD

VERIFY EXISTING CONDITIONS PRIOR TO ONSET OF CONSTRUCTION.

2. THE CONTRACTOR SHALL COORDINATE WITH OWNER FOR ALL EXISTING EQUIPMENT THAT IS TO

BE SALVAGED OR REINSTALLED PRIOR TO THE ONSET OF CONSTRUCTION.

3. THE CONTRACTOR SHALL THOROUGHLY CLEAN THE INTERIOR OF ALL EXISTING DUCTWORK AND

REPAIR ANY DAMAGE PRIOR TO ONSET OF CONSTRUCTION.

4. THE CONTRACTOR SHALL ENSURE ALL DUCTWORK RUNS THAT PENETRATE THE ROOF ARE

PROPERLY SEALED PER THE SPECIFICATIONS.

5. THE CONTRACTOR SHALL PROVIDE DAMPERS, FITTINGS, AND ACCESSORIES TO ENSURE A

FULLY FUNCTIONING SYSTEM PER THE DRAWINGS, DETAILS, AND SPECIFICATIONS.

6. THE CONTRACTOR SHALL UTILIZE THE EXISTING AIR DEVICES ON SITE FOR INSTALLATION IN

NEW CONSTRUCTION.

7. DESIGN BUILD TEAM AND A/E OF RECORD MUST FOLLOW ALL CURRENT VA NATIONAL TIL

STANDARDS, INCLUDING VA NATIONAL CAD STANDARDS, THROUGHOUT DESIGN AND

CONSTRUCTION.

GENERAL MECHANICAL DUCTWORK FLOOR PLAN NOTES

KEYNOTES

3 CONTRACTOR TO CONNECT AIR DEVICE TO EXISTING SUPPLY DUCTWORK, SIZE OF DUCTWORK AND AIR DEVICE TO BE DETERMINED PER FINAL SELECTIONS AND CODE. CONTRACTOR TO FIELD VERIFY AND

INSTALL ASSOCIATED VOLUME DAMPER IF NOT PRESENT.

4 CONTRACTOR TO CONNECT AIR DEVICE TO EXISTING EXHAUST DUCTWORK, SIZE OF DUCTWORK AND AIR DEVICE TO BE DETERMINED PER FINAL SELECTIONS AND CODE. CONTRACTOR TO FIELD VERIFY AND

INSTALL ASSOCIATED VOLUME DAMPER IF NOT PRESENT.

5 CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING FIRE DAMPER. IF NO FIRE DAMPER PRESENT, CONTRACTOR TO PROVIDE NEW.

6 CONTRACTOR TO CONNECT EXISTING AIR TERMINAL UNIT TO MAIN BRANCH IN LOCATION SHOWN.

7 CONTRACTOR TO CONNECT SUPPLY DUCTWORK TO LINEAR DIFFUSER.

8 CONTRACTOR TO CONNECT EXISTING SUPPLY DUCTWORK TO MAIN BRANCH IN LOCATION SHOWN.

9 CONTRACTOR TO CONNECT AIR DEVICE TO EXISTING RETURN DUCTWORK, SIZE OF DUCTWORK AND AIR DEVICE TO BE DETERMINED PER FINAL SELECTIONS AND CODE. CONTRACTOR TO FIELD VERIFY AND

INSTALL ASSOCIATED VOLUME DAMPER IF NOT PRESENT.

10 CONTRACTOR TO CONNECT AIR TERMINAL UNIT TO MAIN BRANCH. ROUTE DUCT TO AIR DEVICE(S). SIZE

OF DUCTWORK AND AIR DEVICE(S) TO BE DETERMINED PER FINAL SELECTIONS AND CODE.

11 CONTRACTOR TO CONNECT AIR DEVICE TO MAIN BRANCH. SIZE OF DUCTWORK AND AIR DEVICE TO BE

DETERMINED PER FINAL SELECTIONS AND CODE.

18 CONTRACTOR TO ROUTE RETURN DUCTWORK DOWN IN LOCATION SHOWN. RETURN GRILLE TO BE

PLACED 7" A.F.F.

19 CONTRACTOR TO REROUTE DUCTWORK UP TO AHU-2 AS NEEDED TO COORDINATE WITH THE NEW 8TH

FLOOR LAYOUT.

23 CONTRACTOR TO PROVIDE ACCESS PANEL FOR ALL EQUIPMENT LOCATED ABOVE HARD CEILING.

24 CONTRACTOR TO INSTALL STAINLESS STEEL DUCTWORK DOWNSTREAM OF HEPA FILTER.

26 CONTRACTOR TO FIELD VERIFY EXISTING DUCTWORK DOWNSTREAM OF HEPA FILTER IS STAINLESS

STEEL. REPLACE WITH STAINLESS STEEL DUCTWORK AS NECESSARY.

27 CONTRACTOR TO INSTALL NEW HEPA FILTER IN LOCATION SHOWN.

N

1/8" = 1'-0"

MECHANICAL DUCT PLAN - SEVENTH FLOOR1

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Office Of Construction & Facilities Management Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

OK ARCH REG. NO. CA02295, EXP. 06/30/2023

OK ENGR REG. NO. CA7127, EXP. 06/30/2023

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

HEALTHCARE PLANNER

OCULUS INC.

1 S. MEMORIAL DR., SUITE 1500

ST. LOUIS, MO 63102

(314) 367-6100

SPUR PROJECT NUMBER: 1791.08

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

SEE FRONT COVER SHEET

FOR APPROVAL SIGNATURE

VERTICAL TRANSPORTATION

ENVIRONMENTAL HYGIENIST

TEC-AN, INC.

2517 S. PURDUE AVE.

OKLAHOMA CITY, OK 73128

(405) 681-7076

LERCH BATES

2001 BRYAN ST., SUITE 1930

DALLAS, TX 75201

(972) 294-5221

/2

/2

:2 :4

P

M

MH100

MECHANICAL HVAC DUCT PLAN -

SEVENTH FLOOR

JLF

57 OF 92JRM

100% RFP DOCUMENTS

CONSTRUCT SURGICAL INTENSIVE

CARE UNIT & RENOVATE

OPERATING ROOMS

08/02/2021

635-436

OKLAHOMA CITY VA HEALTHCARE SYSTEM

921 NE 13TH ST, OKLAHOMA CITY, OK 73104

VAV INSTALLATION COUNT - 7TH FLOOR

Level MARK LOCATION ACTUAL SUPPLY AIRFLOW

7TH FLOOR VAV-7-16 704-POST-OP AREA 325

7TH FLOOR VAV-7-17 732-STORAGE 100

7TH FLOOR VAV-7-18 731-NEURO EQUIP 100

7TH FLOOR VAV-7-19 728-IMAGE EQUIP COMPONENT ROOM 150

7TH FLOOR VAV-7-20 729-GAS CYLINDERS 225

No. REVISION DESCRIPTION DATE

File details come from the government source that posted it. Updated .