AS-102 - TYPICAL FLOOR SIGNAGE PLAN (FLOORS 2-7).pdf
PDF 895 KB Posted
- Solicitation number
- 47PM0325R0002
About this file
This is an architectural signage plan drawing that details the design, placement, and specifications for various signage types across floors 2-7 of the Sheridan Building renovation project at the Armed Forces Retirement Home in Washington DC. The drawing includes detailed specifications for multiple sign types including room identification signs, directional signs, restroom signs, stair signs, community room lettering, and other regulatory signage.
The plan provides specific mounting heights (60" from finished floor), dimensional requirements, and installation details for ADA-compliant signage. Key specifications include Takeform Quad Fusion 06 as the basis of design, Wilsonart finishes, Gotham font, and black lettering. The drawing includes general installation notes requiring coordination of final room numbers with AFRH, proper mounting heights for Braille text (48"-60" AFF), and requirements for the contractor to create a comprehensive signage schedule during the submittal process. The floor plan shows the proposed locations for all signage types across a typical residential floor layout.
View the file
Other files
Show 40 more
Latest 50 of 90 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
A
D
A
A
A
A
A D
A
HH
A A
D
A
A
A A H H
A A
A A
A A
A
AAA
A AA
AA
AA
AA
A
A A A
D D
HH
A
A
AA
A
AA
HH
A
A
A
A
AD
A
H H
H
H
H
HF J
F J
E
E
E L L
L L
E
L L
E E
L
L
L
L
LL L L
E
E E
L L
E
E
D
A
FJF
P
P
P
P
P
P
P P
P P
P
P P
P
P
K A
E
5'
2"
5'
EQ. EQ.
ANODIZED ALUMINUM RAISED ARCHITECTURAL
LETTERING WITH CONCEALED MOUNTING
(TEXT VARIES PER ELEVATION)
FONT: GOTHAM
COMMUNITY ROOM6"
TOILET ROOM IDENTIFICATION
SIGN (MEN)
STAIR SIGN TOILET ROOM IDENTIFICATION
SIGN (WOMEN)
FIRE EQUIPMENT SIGN IN CASE OF FIRE SIGN AUTHORIZED PERSONNEL
ONLY
CHANGABLE ROOM IDENTIFICATION SIGN
WITH PRINTED INSERT
SOFFIT MOUNTED
DIRECTIONAL SIGN
CEILING MOUNTED
DIRECTIONAL SIGN
COMMUNITY MESSAGE BOARD
TOILET ROOM IDENTIFICATION
SIGN (UNISEX)
4'-0"
3' -0
V
IE
W A
B
LE
A R
E A
2' -0
/2
V
IE
W A
B
LE
A R
E A
2' -0
/2
1'-7 1/2" 1'-7 1/2"
COMMUNITY NAME HERERAISED TEXT
1/4"
1"
1 1/2"
1/ 4"
1"
1/
4" 1/
4" 5"
1/
4"RAISED SYMBOL
FRAMING: PLAM-#
DOOR HARDWARE
DOOR HINGE
GL-#
WINDOW BACKER
3'-4"
6"
4" 2'-10 1/2"
TEXT HERE
RAISED SYMBOL
CEILING RAISED TEXT
3'-4"
4" 2'-10 1/2"
"TEXT HERE
RAISED TEXT
BRAILLE TO BE
PER ADA CODE
RAISED SYMBOL
RESTROOM
RAISED SYMBOL
RAISED TEXT
/4
8 1/2"
6"1 1/4"
1/
2" 1/
2"6 1/
4" 1/
2"
AUTHORIZED
PERSONNEL ONLY
/4
1/
2" 1/
2"6 1/
4" 1/
2"
8 1/2"
1 1/4" 6"
RAISED TEXT
BRAILLE TO BE
PER ADA CODE
RAISED SYMBOL
NOTE: [MODIFY TEXT FOR EACH ROOM
NAME; EX. HOUSEKEEPING CLOSET,
SOILED ROOM, MECHANICALROOM, ETC.]
IN CASE OF FIRE
USE STAIR FOR EXIT
DO NOT USE ELEVATOR
1/
2" 1/
2"6 1/
4" 1/
2"
/4
8 1/2"
1 1/4" 6"
RAISED TEXT
RAISED SYMBOL
1/
2" 1/
2"6 1/
4" 1/
2"
/4
8 1/2"
1 1/4" 6"
RAISED TEXT
RAISED SYMBOL
BRAILLE TO BE
PER ADA CODE
FIRE EQUIPMENT
1/
2" 1/
2"6 1/
4" 1/
2"
/4
8 1/2"
1 1/4" 6"
RAISED TEXT
RAISED SYMBOL
BRAILLE TO BE
PER ADA CODE
STAIRMEN WOMEN
1/
2" 1/
2"
3/
4"
/4
8 1/2"
1 1/4" 6"
RAISED TEXT
RAISED SYMBOL
BRAILLE TO BE
PER ADA CODE
1/
2" 1/
2"
3/
4"
/4
8 1/2"
1 1/4" 6"
RAISED TEXT
RAISED SYMBOL
BRAILLE TO BE
PER ADA CODE
SIGNAGE NOTES:
BASIS OF DESIGN: TAKEFORM QUAD FUSION 06
FACE FINISH: WILSONART D327-60 PEPPER DUST
BACKER FINISH: WILSONART 5025K-22 GLACIER
QUARTZITE
FONT TYPE: GOTHAM (ADA)
FONT COLOR: BLACK
FONT SIZE (UNLESS NOTED OTHERWISE):
*TEXT SHOWN FOR REFERENCE ONLY;
FONT, SIZE, JUSTIFICATION AND COLOR ARE
TO BE IN ACCORDANCE WITH SPECIFICATION
INSERT TEXT:
*PRINTED INSERT INFORMATION:
CONFIRM ALL PRINTED INSERT TEXT DURING
THE SUBMITTAL PROCESS
HA B D E F JGC
L M
KI
4"
N
UPDATABLE BY
USER INSERT
RAISED TEXT
BRAILLE TO BE
PER ADA CODE
8 1/2"
1 1/4" 6"
1/
2"
3"
7"
1/ 2"
1/ 2"
1/ 2"
EXIT
RAISED TEXT
BRAILLE TO BE
PER ADA CODE
7/8" 6 3/4"
8 1/2"
3/ 8"
1/
4"
3/ 8"
4"
EXIT SIGN
6"1 1/2"
9"
TEXT HERE
RAISED TEXT
BRAILLE TO BE
PER ADA CODE
1/ 2"
1/
2" 1/
2"
1/
2"
STANDARD ROOM
IDENTIFICATION SIGN
EVACUATION SIGN AND PLAN WITH
PRINTED INSERT
RAISED TEXT TEXT HERE
11"
1 1/2" 8" 5/ 8"
1' -5
/4
5/
8" 3"
5/ 8"
ACCOMMODATES
INSERT;
UPDATABLE BY
USER
O
CONVEX SAFETY MIRROR. 18" DIAMETER, 160 DEGREE
VIEW CORNER MOUNTED. BOD: ULINE MODEL H-1307
P ø 1' - 6"
1/ 2"
1/ 2"
Q
MAXIMUM OCCUPACY SIGN
1/
2" 1/
2"6 1/
4"
8 1/2"
1 1/4" 6"
RAISED TEXT
BRAILLE TO BE
PER ADA CODE
MAXIMUM
OCCUPANCY
1/ 2"
N
DATE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
CLIENT:
418 BEAVER STREET
SEWICKLEY, PA 15143
PH: 412.287.7333
www.aeworks.com
PROFESSIONAL:
COPYRIGHT 2024 BY AE WORKS LTD ALL RIGHTS RESERVED.
SUBMISSION:
CONSTRUCTION BID
DOCUMENTS
AE WORKS®
A u to d e s k D o c s
/A F
R H
-0
S h e ri d a n /A
F R
H -0
A R
C H
-2
.r v t
/1
/2
:4
:0
P
M
AS-102
AD
BAS
AFRH-033
TYPICAL FLOOR
SIGNAGE PLAN (FLOORS
2-7)
AFRH SHERIDAN
RENOVATION
140 ROCK CREEK
CHURCH ROAD,
NORTHWEST,
WASHINGTON, DC
ARMED FORCES
RETIREMENT HOME -
WASHINGTON D.C.
11/13/24
1/16" = 1'-0"
TYPICAL FLOOR SIGNAGE PLAN (FLOORS 2-7)SIGNAGE MOUNTING HEIGHT
GENERAL SIGNAGE INSTALLATION NOTES
1 NOT USED.
2 COORDINATE FINAL ROOM NUMBERS AND NAMES WITH AFRH. ROOM NUMBERS AND NAMES ON FLOOR PLANS ARE
FOR CONSTRUCTION REFERENCE ONLY
3 TOP OF THE SIGN MUST BE MOUNTED AT 60" FROM FINISHED FLOOR; BRAILLE IS TO BE NO LOWER THAN 48" AFF
AND NO HIGHER THAN 60" AFF.
4 ROOM NUMBER ID SIGNAGE IS MOUNTED AT 2" FROM THE EDGE OF THE DOOR FRAME, MOUNTED ON THE HANDLE
SIDE OF THE DOOR
5 SEE SPECIFICATION FOR SIGNAGE BASIS OF DESIGN.
6 CONTRACTOR TO CREATE SIGNAGE SCHEDULE IN THE SUBMITTAL PROCESS; AFRH TO PROVIDE ROOM NAME AND ROOM NUMBER INFORMATION DURING THE SUBMITTAL PROCESS; SIGNAGE VENDOR TO PROVIDE TEMPLATE TO AFRH FOR SIGNAGE SCHEDULE OF ALL SIGNS FOR ROOM NAMES, PRINTED NAMES, DIRECTORY TEXT, AND
DIRECTIONAL SIGNS.
SIGNAGE LEGEND
NO DATE REVISION
1 02/12/2025 BID ADDENDUM
| Sheets |
| A102 - OVERALL SECOND FLOOR PLAN |
| A102B - SECOND FLOOR PLAN B |
| A112B - SECOND FLOOR REFLECTED CEILING PLAN B |
| A405 - CLINICAL AREAS/NURSE STATIONS - FIRST FLOOR |
| A406 - CLINICAL AREAS/ NURSE STATIONS - FIRST FLOOR |
| A407 - NORTH SERVERY |
| A408 - SOUTH SERVERY |
| A409 - ENLARGED TOILET ROOM PLANS AND ELEVATIONS |
| A412 - ENLARGED RESIDENT ROOM SHOWERS |
| A427 - SPA ROOMS AND LAUNDRY ROOMS |
| A601 - DOOR SCHEDULE, TYPES, DETAILS |
| A602 - DOOR SCHEDULE, TYPES, DETAILS |
| AI401 - ENTRANCE LOBBY FINISH PLAN AND ELEVATIONS |
| AI402 - FIRST FLOOR ELEVATOR LOBBY FINISH PLANS AND ELEVATIONS |
| AI403 - SERVERY FINISH PLAN AND ELEVATIONS |
| AI405 - FIRST FLOOR ENLARGED CORRIDOR PLANS AND ELEVATIONS |
| AI406 - FIRST FLOOR TOILET ROOM FINISH PLANS AND ELEVATIONS |
| AI408 - TYPICAL NORTH/ SOUTH ELEVATOR LOBBY FINISH PLANS (FLOORS 2-7) |
| AS-101 - FIRST FLOOR SIGNAGE PLAN |
| AS-102 - TYPICAL FLOOR SIGNAGE PLAN (FLOORS 2-7) |
File details come from the government source that posted it. Updated .