A503 - EXTERIOR WALL SECTION DETAILS.pdf
PDF 694 KB Posted
- Solicitation number
- 47PM0325R0002
About this file
This is an architectural drawing sheet (A503) containing 13 detailed exterior wall section details for the Sheridan Building renovation project at the Armed Forces Retirement Home in Washington DC. The drawing sheet displays various construction details including roof and door sill connections, expansion joints, loading dock components, trash platform connections, metal deck roof transitions, and flagpole attachment specifications.
The details show precise construction specifications for components like fire-rated assemblies, waterproofing membranes, metal panel systems, flashing installations, and structural connections. Key elements include 2-hour fire-rated assemblies, air and water barriers, metal panel systems with associated trim, concrete and steel structural elements, and critical waterproofing details at transitions and penetrations. The drawings are at a scale of 1"=1'-0" and include comprehensive annotations for materials, assemblies and critical dimensions. This sheet is part of the construction bid documents package dated February 2025 and was prepared by AE Works Ltd. for the Armed Forces Retirement Home renovation project.
View the file
Other files
Show 40 more
Latest 50 of 90 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
0" (317.80')
C.5
EXTERIOR DOOR
-REFER TO DOOR SCHEDULE
PT WOOD BLOCKING
DOOR SILL SET IN SEALANT BED
CONCRETE CURB
- REFER TO STRUCT. DWGS
METAL TRIM - PAINT TO
MATCH DOOR FRAME
FINISH FLOOR
- REFER TO FINISH PLANS
AIR AND WATER BARRIER
STEEL BEAM
- REFER TO STRUCT. DWGS
1'
CANT STRIP
MEMBRANE FLASHING
- WRAP UP AND OVER CURB
METAL FLASHING
R4 5/8" GYPSUM BOARD
2 HR FIRE SPRAY AT BEAMS,
UL DESIGN # D743
1 HR FIRE SPRAY AT ROOF AND
SUPPORTING SECONDARY
MEMBERS,
UL DESIGN # D743
RESWELLABLE WATERSTOP,
TYPICAL AT ALL CONCRETE COLD JOINTS
END DAM FLASHING, TYPICAL FOR ALL
EXTERIOR DOORS, STOREFRONTS
AND CURTAIN WALLS
SECOND FLOOR
14' - 0"
R6
METAL CLOSURE ANGLE
3" 2HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN:
EMSEAL DFR2
FACE OF WALL PANEL BEYOND
PT WOOD BLOCKING
METAL FLASHING WITH DRIP EDGE
SEALANT
MEMBRANE FLASHING
- WRAP UP OVER CURB
CANT STRIP
WRAP AIR AND WATER BARRIER
UP OVER PT BLOCKING
PT WOOD BLOCKING
EXPANSION JOINT BELLOWS FLASHING
8" M
IN
PT WOOD BLOCKING
5/8" GYPSUM
BOARD
EXTERIOR DOOR
-REFER TO DOOR SCHEDULE
DOOR SILL SET IN SEALANT BED
SHIM AS REQUIRED
9"
PT WOOD BLOCKING
METAL FLASHING
RIGID INSULATION
SEALANT AS REQUIRED BY EXPANSION
JOINT BELLOWS FLASHING MFR
1 HR FIRE SPRAY AT ROOF,
UL DESIGN # P732
2 HR FIRE SPRAY AT BEAMS,
UL DESIGN #P732
END DAM FLASHING,
TYPICAL FOR ALL EXTERIOR
DOORS, STOREFRONTS AND
CURTAIN WALLS
ROOF EXPANSION JOINT.
BASIS OF DESIGN: EMSEAL ROOFJOINT
6" CMU CURB WITH SOLID TOP BLOCK
SAWCUT AT ANGLE PARALLEL TO BALCONY
SLAB, REFER TO STRUCT DWG
THIRD FLOOR
24' - 6"
G.6G.5a
W1
STRUCTURAL DECK
-REFER TO STRUCTURAL PLANS
1'
2'
METAL FLASHING
FLASHING STRIP
VAPOR BARRIER
MEMBRANE FLASHING,
LAP OVER FLASHING
FIRST FLOOR
0" (317.80')
F.5 F.6
R4
8" 2'
CANT STRIP
MEMBRANE FLASHING
METAL FLASHING
BASE TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
PROTECTION BOARD
1 HR FIRE SPRAY AT ROOF
AND SUPPORTING
SECONDARY MEMBERS,
UL DESIGN # D743
2 HR FIRE SPRAY AT BEAMS,
UL DESIGN # D743
G.6
SLIP JOINT - SEALANT
WITH BACKER ROD
CFMF BRACING
-REFER TO STRUCT. DWGS
TRIM - MATCH ADJACENT PANEL
MATERIAL AND FINISH
TRIM - MATCH ADJACENT PANEL
MATERIAL AND FINISH
SLIP JOINT FILLER
BREAK IN SUBGIRT SYSTEM
NOTE: CONTRACTOR TO
COORDINATE WITH METAL
PANEL MRF FOR SLIP JOINT
DETAIL
BACKER ROD WITH
CONVEX LOOP MEMBRANE
FLASHING AT EXPANSION JOINT,
BOTH SIDES OF CFMF
LAP AIR BARRIER OVER CONVEX
LOOP MEMBRANE FLASHING
FIRST FLOOR
0" (317.80')
32S
HSS MEMBER
-REFER TO STRUCTURAL DWGS
STEEL BAR GRATING
EXISTING LIMESTONE PANEL
STEEL PLATE
-REFER TO STRUCTURAL DWGS
STEEL COVER PLATE
- WELD TO HSS MEMBER
PERIMETER FILLET SEALANT
PERIMETER BED SEALANT
EXISTING LIMESTONE PANEL
3/8" PERIMETER FILLET SEALANT
PERIMETER BED SEALANT
G.6
W1
FINISH FLOOR
- REFER TO FINISH PLANS
COMPOSITE SLAB
- REFER TO FINISH PLANS
2 HR FIRE SPRAY AT DECK,
UL DESIGN # D7432 HR FIRE SPRAY AT BEAM,
UL DESIGN # D743
STEEL BEAM
- REFER TO STRUCTURAL DWGS
STEEL COLUMN BEYOND
CFMF
GYPSUM SHEATHING
CFMF
STEEL BEAM BEYOND
- REFER TO STRUCTURAL DWGS
CLOSED CELL INSULATION
AIR AND WATER BARRIER
METAL PANEL SYSTEM
METAL FLASHING
SELF-ADHERED MEMBRANE
FLASHING STRIP
2HR SLAB EDGE FIRE
STOPPING - REFER TO
SPECIFICATIONS
2HR RATED BOARD
BASIS OF DESIGN: GCP N-300 SERIES
BASEMENT
-14' - 0"
G.6
GRADE BEAM
- REFER TO STRUCTURAL DWGS
GRAVEL BASE
CONCRETE SLAB
- REFER TO STRUCTURAL DWGS
EXISTING WALL TO REMAIN
METAL PANEL SYSTEM
GYPSUM SHEATHING
CFMF
2'
/2
STEEL COLUMN BEYOND
SEALANT AND BACKER ROD
BASE TRIM - MATCH ADJACENT
PANEL MATERIAL AND FINISH
GRANITE PANEL
METAL PANEL SYSTEM
SEALANT AND BACKER ROD
BASE TRIM - MATCH ADJACENT PANEL
MATERIAL AND FINISH
METAL FLASHING, EXTEND 1/2"
BEYOND CLADDING
GRANITE PANEL
NOTE: REFER TO TYPICAL
STONE ATTACHMENT DETAILS
FOR ADDITIONAL INFORMATION
FIELD DRILL WEEP AT BOTTOM
METAL FLASHING
AIR & WATER BARRIER
SEALANT BED
METAL FLASHING
SELF-ADHERED MEMBRANE FLASHING STRIP
SELF-ADHERED MEMBRANE FLASHING STRIP
SEALANT BED
METAL FLASHING
SELF-ADHERED MEMBRANE
FLASHING STRIP
METAL FLASHING, EXTEND
1/2" BEYOND CLADDING
FIELD DRILL WEEP AT BOTTOM
METAL FLASHING
SELF-ADHERED MEMBRANE
FLASHING STRIP
1/8" / FT
THIRD FLOOR
24' - 6"
17.6
METAL FLASHING -
EXTEND TO COVER OVER
TERMINATION BAR
TPO AND FLASHING
MEMBRANE- WRAP OVER EDGE
RETAINING ANGLE
EXPANSION JOINT SEALANT
2' - 0"
EDGE RETAINER
R3
SEPARATION FABRIC AND DRAINAGE
COMPOSITE OVER WATERPROOFING
AND FLASHING MEMBRANE
STONE BALLAST
8" M
IN
CLOSED CELL INSULATION
1'
1"
5"
R6
CFMF
-REFER TO STRUCT DWGS
CANT STRIP
MEMBRANE FLASHING
-WRAP UP AND OVER PARAPET
VAPOR BARRIER
-WRAP UP TO CANT
1/2" GYPSUM SHEATHING
PARAPET BEYOND
METAL COPING
-MATCH ADJACENT COPING TRIM
PT WOOD BLOCKING
SEALANT
ROOF EXPANSION JOINT.
BASIS OF DESIGN: EMSEAL ROOFJOINT
MEMBRANE FLASHING AT CURB
WRAP AIR AND WATER BARRIER UP AND
OVER MEMBRANE FLASHING AND CURB
PT WOOD BLOCKING
SEALANT AS REQUIRED BY EXPANSION
JOINT BELLOWS FLASHING MFR
2HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN
EMSEAL DFR2
TERMINATION BAR
MEMBRANE FLASHING
-WRAP UP AND OVER PARAPET
SEPARATION SHEET BETWEEN MEMBRANE
AND AIR & WATER BARRIER AS REQUIRED
PER MFR
AIR & WATER BARRIER
SECOND FLOOR
14' - 0"
1N
W2
COUNTER FLASHING WITH
REGLET AND SEALANT
METAL DECKING
-REFER TO STRUCTURAL DWGS
METAL FLASHING
8" M
IN
LOW PROFILE STANDING
SEAM METAL ROOFING
HSS BEAM
-REFER TO STRUCTURAL DWGS
BENT PLATE
-REFER TO STRUCTURAL DWGS
BUTTON SEAL OVER
FASTENER HEADS
LAP SEAM METAL ROOFING
METAL DECKING
-REFER TO STRUCTURAL DWGS
METAL TRIM
BENT PLATE
-REFER TO STRUCTURAL DWGS
HSS BEAM
-REFER TO STRUCTURAL DWGS
EIGHTH FLOOR
79' - 9 1/2"
NINTH FLOOR
93' - 1"
CLOSED CELL INSULATION
REMOVE, CUT AND REINSTALL
EXISTING LIMESTONE PANEL
AS REQUIRED TO INSTALL
FLAGPOLE SUPPORTS
HSS MEMBERS
-REFER TO STRUCTURAL DWGS
EXISTING CONCRETE BEAM
AND SLAB TO REMAIN
ANCHOR
-REFER TO STRUCTURAL DWGS
COVER PLATE AT FACADE
OPENING, PER FLAGPOLE
MANUFACTURER
FLAGPOLE ASSEMBLY PER
FLAGPOLE MANUFACTURER
REMOVE, CUT AND REINSTALL
EXISTING LIMESTONE PANEL
AS REQUIRED TO INSTALL
FLAGPOLE SUPPORTS
HSS MEMBERS
-REFER TO STRUCTURAL DWGS
ANCHOR
-REFER TO STRUCTURAL DWGS
SEALANT AND BACKER ROD
METAL FLASHING
BED SEALANT AROUND
PERIMETER
3/8"
FILLET SEALANT AROUND
PERIMETER
FASTENER WITH
GASKET SEAL
G.6
STEEL COLUMN BEYOND
CFMF
GYPSUM SHEATHING
CFMF
CFMF
GYPSUM SHEATHING
RIGID INSULATION
METAL PANEL SYSTEM
AIR AND WATER BARRIER
METAL PANEL SYSTEM
METAL PANEL SYSTEM
GYPSUM SHEATHING
CFMF
SOFFIT BACK TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
CLOSED CELL INSULATION
BACKUP Z CLIP
AIR & WATER BARRIER
SUBGIRT SYSTEM
SUBGIRT SYSTEM
JH.1
METAL PANEL SYSTEM
SOFFIT BACK TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
METAL PANEL SYSTEM
GYPSUM SHEATHING
CFMF
CFMF
GYPSUM SHEATHING
AIR & WATER BARRIER
RIGID INSULATION
STEEL COLUMN BEYOND
-REFER TO STRUCTURAL DWGS
EXISTING LIMESTONE TO REMAIN
EXISTING CMU TO REMAIN
BACKUP Z CLIP
SUBGIRT SYSTEM
SUBGIRT SYSTEM
DATE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
CLIENT:
418 BEAVER STREET
SEWICKLEY, PA 15143
PH: 412.287.7333
www.aeworks.com
PROFESSIONAL:
COPYRIGHT 2024 BY AE WORKS LTD ALL RIGHTS RESERVED.
SUBMISSION:
CONSTRUCTION BID
DOCUMENTS
AE WORKS®
A u to d e s k D o c s
/A F
R H
-0
S h e ri d a n /A
F R
H -0
A R
C H
-2
.r v t
/1
/2
:5
:5
A
M
A503
AEW
Checker
AFRH-033
EXTERIOR WALL
SECTION DETAILS
AFRH SHERIDAN
RENOVATION
140 ROCK CREEK
CHURCH ROAD,
NORTHWEST,
WASHINGTON, DC
ARMED FORCES
RETIREMENT HOME -
WASHINGTON D.C.
11/13/24
1" = 1'-0"
SECTION DETAIL AT ROOF AND DOOR SILL
1" = 1'-0"
SECTION DETAIL AT EXPANSION JOINT
1" = 1'-0"
SECTION DETAIL AT METAL DECK ROOF
1" = 1'-0"
SECTION DETAIL AT MOD BIT ROOF AND METAL PANEL
1" = 1'-0"
SECTION DETAIL AT SLIP JOINT
1" = 1'-0"
SECTION AT TRASH PLATFORM CONNECTION
1" = 1'-0"
SECTION DETAIL AT LOADING DOCK COLUMN
1" = 1'-0"
SECTION DETAIL AT LOADING DOCK
1" = 1'-0"
SECTION DETAIL AT ROOF DECK TRANSITION
1" = 1'-0"
SECTION DETAIL AT TRASH PLATFORM ROOF
1" = 1'-0"
FLAGPOLE ATTACHMENT DETAIL
1" = 1'-0"
SECTION DETAIL AT LOADING DOCK COLUMN
1" = 1'-0"
SECTION DETAIL AT LOADING DOCK PILASTER
NO DATE REVISION
1 02/12/2025 BID ADDENDUM1
AC
JW
| Sheets |
| A503 - EXTERIOR WALL SECTION DETAILS |
| A504 - EXTERIOR WALL SECTION DETAILS |
| A516 - EXTERIOR PLAN DETAILS |
| A517 - EXTERIOR PLAN DETAILS |
| A560 - TYPICAL ROOF DETAILS |
| A570 - EXTERIOR EXPANSION JOINT DIAGRAMS |
File details come from the government source that posted it. Updated .