About this file

This is a technical specification document (Section 088700) for window film installation at the Armed Forces Retirement Home's Sheridan Building. The specification details requirements for an optically clear micro-layered polyester window film containing at least 220 layers, with a pressure-sensitive adhesive on one side and durable acrylic abrasion resistant coating on the other. The film must meet specific performance requirements including a minimum Graves Area Tear Strength of 1,200 lbs%, flame spread index no greater than 25, smoke developed index no greater than 55, and UV light rejection of 99.9%.

The document outlines detailed installation requirements, including quality assurance measures requiring the manufacturer to have 10+ years experience and installers to have 5+ years experience with similar projects. Installation must be performed by an Authorized 3M dealer to validate the warranty, which covers anti-graffiti films for 1 year outdoors and 10 years indoors. The specification requires submission of product data, third-party test reports, verification samples, and performance data. The basis of design is listed as Solyx 3140, with specific physical properties detailed including 8.0 mil thickness, tensile strength of 24,000 psi (MD)/26,000 psi (TD), and precise installation procedures using slip solution application methods.

View the file

Other files

File Type Posted
Amendment 0006 Solicitation 47PM0325R0002 2025 03 25.pdf PDF
Amendment 0005 RFI Responses 150 - 336 2025 03 18.pdf PDF
Amendment 0005 Solicitation 47PM0325R0002 2025 03 18 (2).pdf PDF
Amendment 0004 Solicitation 47PM0325R0002 2025 03 13.pdf PDF
H103 - CHILLER PLANT.pdf PDF
Amendment 0003 Technical Evaluation Factors-Best Value_ Trade Off 2025 03 04.pdf PDF
Amendment 0003 Solicitation 47PM0325R0002 2025 03 04.pdf PDF
A517 - EXTERIOR PLAN DETAILS.pdf PDF
A516 - EXTERIOR PLAN DETAILS.pdf PDF
087113 - Automatic Door Operator.pdf PDF
079500 - Exterior Expansion Control.pdf PDF
A427 - SPA ROOMS AND LAUNDRY ROOMS.pdf PDF
084113 - Aluminum-Framed Entrances and Storefronts.pdf PDF
A406 - CLINICAL AREAS- NURSE STATIONS - FIRST FLOOR.pdf PDF
AD100A - BASEMENT DEMOLITION PLAN A.pdf PDF
Amendment 0003 Solicitation_GC AFRH 2025 03 04.pdf PDF
236416 FL - Centrifugal Water Chillers- Addendum 3.pdf PDF
AI407 - TYPICAL ELEVATOR LOBBY FINISH PLANS AND ELEVATIONS (FLOORS 2-7).pdf PDF
107113 - Exterior Sun Control Devices.pdf PDF
AD100B - BASEMENT DEMOLITION PLAN B.pdf PDF
A405 - CLINICAL AREAS-NURSE STATIONS - FIRST FLOOR.pdf PDF
HD103 - CHILLER PLANT DEMO PLAN.pdf PDF
AI408 - TYPICAL NORTH- SOUTH ELEVATOR LOBBY FINISH PLANS (FLOORS 2-7).pdf PDF
A409 - ENLARGED TOILET ROOM PLANS AND ELEVATIONS.pdf PDF
087100 - Door Hardware.pdf PDF
101423.16 - Panel Signage.pdf PDF
A504 - EXTERIOR WALL SECTION DETAILS.pdf PDF
000110 Table of Contents.pdf PDF
H603 - HVAC DETAILS.pdf PDF
AFRH-Sheridan Pre-Bid Addendum 2-12-25.pdf PDF
081416 - Flush Wood Doors.pdf PDF
A601 - DOOR SCHEDULE TYPES DETAILS.pdf PDF
S542 - STRUCTURAL BALCONY ENCLOSURE DETAILS.pdf PDF
A560 - TYPICAL ROOF DETAILS.pdf PDF
A503 - EXTERIOR WALL SECTION DETAILS.pdf PDF
A602 - DOOR SCHEDULE TYPES DETAILS.pdf PDF
S521 - STRUCTURAL ANNEX FRAMING DETAILS.pdf PDF
095000 - Wood Panel Ceiling.pdf PDF
S552 - STRUCTURAL TRASH CHUTE GENERATOR ENCLSOURE BALCONY ENCLOSURE DETAILS.pdf PDF
Amendment 0003 RFI Responses 1-149 2025 03 04.pdf PDF
235700 FL - Heat Exchangers for HVAC.pdf PDF
S401 - STRUCTURAL ROOF FRAMING PARTIAL PLANS.pdf PDF
Amendment 0003 Solicitation 47PM0325R0002 2025 03 04.pdf PDF
H804 - CONTROL DIAGRAMS.pdf PDF
AEWLA22050. Geotechnical Report. 10142022.pdf PDF
A412 - ENLARGED RESIDENT ROOM SHOWERS.pdf PDF
089119 - Fixed Louvers.pdf PDF
A112B - SECOND FLOOR REFLECTED CEILING PLAN B.pdf PDF
AI406 - FIRST FLOOR TOILET ROOM FINISH PLANS AND ELEVATIONS.pdf PDF
A102B - SECOND FLOOR PLAN B.pdf PDF
Show 40 more

Latest 50 of 90 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Armed Forces Retirement Home Sheridan Building Design Documents | Specifications

Bid Addendum 2/12/25

WINDOW FILM 088700-1

SECTION 088700 WINDOW FILM

PART 1 GENERAL

1.1 SUMMARY

A. Window Film.

1.2 RELATED SECTIONS

A. Section 088000 Glazing.

1.3 REFERENCES

1. ASTM D 882 - Standard Test Method for Tensile Properties of Thin Plastic Sheeting.

2. ASTM E 903 - Standard Methods of Test for Solar Absorbance, Reflectance and

Transmittance of Materials Using Integrating Spheres.

3. ASTM F1642 - Standard Method of Test for Glazing and Glazing Systems Subject to

Airblast Loadings

B. Consumer Products Safety Commission 16 CFR, Part 1201 - Safety Standard for Architectural Glazing Materials.

C. GSA-TS01 - Standard Test for Glazing and Glazing Systems Subject to Airblast Loadings.

D. NFRC 100/200 (Formerly ASTM E903) - Standard Methods of Test for Solar Absorbance, Reflectance and Transmittance of Materials Using Integrating Spheres.

E. ISO 16933, International Standard for Glass in Building: Explosion-resistant security glazing - Test and classification for arena air-blast testing.

F. Underwriters Laboratories Inc. (UL): UL 972 - Burglary Resisting Glazing Material.

G. Window 6.3 - A Computer Tool for Analyzing Window Thermal Performance; Lawrence Berkeley Laboratory.

1.4 DEFINITIONS

A. Light to Solar Gain Ratio: The ratio of visible light transmission to Solar Heat Gain Coefficient.

1.5 PERFORMANCE REQUIREMENTS

A. Tear Resistance:

1. Minimum Graves Area Tear Strength of 1,200 lbs% as measured on coated film product, without liner, per ASTM D1004.

B. Flammability: Surface burning characteristics when tested in accordance ASTM E 84, demonstrating film applied to glass rated Class A for Interior Use:

1. Flame Spread Index: no greater than 25.

2. Smoke Developed Index: no greater than 55.

Bid Addendum 2/12/25

WINDOW FILM 088700-2

C. Abrasion Resistance:

1. Film shall have a surface coating that is resistant to abrasion such that less than 3 percent increase of transmitted light haze will result when tested in accordance to ASTM D 1044 using 100 cycles, 500 grams weight, and the CS10F Calibrase Wheel.

D. UV Light Rejection:

1. Minimum of 99.9% UV light rejection (300 - 380 nm), per ASTM E903, as determined with film applied on 1/4 inch clear glass.

1.6 SUBMITTALS

A. Product Data: Manufacturer's current technical literature on each product to be used, including:

1. Manufacturer's Data Sheets.

2. Preparation instructions and recommendations.

3. Storage and handling requirements and recommendations.

4. Installation methods.

B. 3rd Party Test Report Submittal Requirements. Submit the following 3rd Party test reports indicating compliance with the test values listed in this section.

1. Flammability Testing, ASTM E84.

2. Film Properties Testing, ASTM D882.

3. Abrasion Resistance Testing, ASTM D1044.

4. Peel Strength Testing, ASTM D3330.

5. Tear Resistance Testing, ASTM D1004.

6. Puncture Strength Testing, ASTM D4830.

C. Verification Samples: For each film specified, two samples representing actual film color and pattern.

D. Performance Submittals: Provide laboratory data of emissivity and calculated window U- Factors for various outdoor temperatures based upon established calculation procedure defined by the ASHRAE Handbook of Fundamentals, Chapter 29, or Lawrence Berkeley Laboratory Window 5.2 Computer Program.

1.7 QUALITY ASSURANCE

A. Manufacturer Qualifications: All primary products specified in this section will be supplied by a single manufacturer with a minimum of ten years experience.

1. Provide documentation that the adhesive used on the specified films is a Pressure

Sensitive Adhesive (PSA).

B. Installer Qualifications: All products listed in this section are to be installed by a single installer with a minimum of five years demonstrated experience in installing products of the same type and scope as specified.

1. Provide documentation that the installer is authorized by the Manufacturer to perform

Work specified in this section.

2. Provide a commercial building reference list of 5 properties where the installer has applied window film. This list will include the following information:

a. Name of building.

b. The name and telephone number of a management contact.

c. Type of glass.

d. Type of film and/or film attachment system.

e. Amount of film and/or film attachment system installed.

f. Date of completion.

Bid Addendum 2/12/25

WINDOW FILM 088700-3

3. Provide a Glass Stress Analysis of the existing glass and proposed glass/film combination as recommended by the film manufacturer.

4. Provide an Film application analysis to determine available energy cost reduction and savings.

C. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.

1. Finish areas designated by Architect.

2. Do not proceed with remaining work until workmanship, color, and sheen are approved by Architect.

3. Refinish mock-up area as required to produce acceptable work.

1.8 DELIVERY, STORAGE, AND HANDLING

A. Follow Manufacturer's instructions for storage and handling.

B. Store products in manufacturer's unopened packaging until ready for installation.

C. Store and dispose of hazardous materials, and materials contaminated by hazardous materials, in accordance with requirements of local authorities having jurisdiction.

1.9 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

1.10 WARRANTY

A. At project closeout, provide to Owner or Owners Representative an executed current copy of the manufacturer's standard limited warranty against manufacturing defect, outlining its terms, conditions, and exclusions from coverage.

B. In order to validate warranty, installation must be performed by an Authorized 3M dealer and according to Manufacturer's installation instructions. Verification of Authorized 3M dealer can be confirmed by submission of active 3M dealer code number.

C. Anti-graffiti films are warranted for a period of 1 year when installed outdoors and for a period of 10 years when installed indoors.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Basis of Design: Solyx 3140. Refer to Finish Schedule.

2.2 WINDOW FILM

A. Optically clear micro-layered polyester, laminated to an optically clear multi-layered polyester film containing at least 220 layers with a pressure sensitive adhesive on one side and durable acrylic abrasion resistant coating on the other side. The adhesive is pressure-activated, not water-activated, and forms a physical bond, not chemical bond, to the glass. Films contain no metals, but so contain infrared-absorbing carbon, metal oxide particles, or both.

1. Physical / Mechanical Performance Properties:

a. Film Color: Virtually clear with at least 220 layers.

ErnieJoy Cloud

Bid Addendum 2/12/25

WINDOW FILM 088700-4

b. Thickness: Nominal 8.0 mils

c. Tensile Strength (ASTM D 882): 24,000 psi (MD) / 26,000 psi (TD)

d. Break Strength (ASTM D 882): 200 lbs/in (MD) / 215 lbs/in (TD)

e. Percent Elongation at Break (ASTM D882): 104% (MD) / 118% (TD)

f. Yield Strength (ASTM D882): 16,000 psi (MD)

g. Percent Elongation at Yield (ASTM D882): 8% (MD)

h. Graves Tear Resistance (ASTM D1004):

1) Maximum Force: 35 lbs (MD) / 36 lbs (TD)

2) Maximum Strain: 56% (MD) / 50% (TD)

3) Graves Area Tear Resistance: 1,100 lbs% (MD) / 1,100 lbs% (TD)

i. Puncture Propagation Tear (ASTM D 2582): 10 lbf

2. Uniformity: No noticeable pin holes, streaks, thin spots, scratches, banding or other optical defects.

3. Variation in Total Transmission across the Width: Less than 2 percent over the average at any portion along the length.

4. Identification: Labeled as to Manufacturer as listed in this Section.

PART 3 EXECUTION

3.1 EXAMINATION

A. Film Examination:

1. If preparation of glass surfaces is the responsibility of another installer, notify Architect in writing of deviations from manufacturer's recommended installation tolerances and conditions.

a. Glass surfaces receiving new film should first be examined to verify that they are free from defects and imperfections, which will affect the final appearance.

2. Do not proceed with installation until glass surfaces have been properly prepared and deviations from manufacturer's recommended tolerances are corrected. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result under the project conditions.

3. Commencement of installation constitutes acceptance of conditions.

3.2 PREPARATION

A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

C. Refer to Manufacturer's installation instructions for methods of preparation for Impact Protection Adhesive or Impact Protection Profile film attachment systems.

3.3 INSTALLATION

A. Film Installation, General:

1. Install in accordance with manufacturer's instructions.

2. Cut film edges neatly and square at a uniform distance of 1/8 inch (3 mm) to 1/16 inch

(1.5 mm) of window sealant. Use new blade tips after 3 to 4 cuts.

3. Spray the slip solution, composed of one capful of baby shampoo or dishwashing liquid to 1 gallon of water, on window glass and adhesive to facilitate proper positioning of film.

4. Apply film to glass and lightly spray film with slip solution.

5. Squeegee from top to bottom of window. Spray slip solution to film and squeegee a second time.

6. Bump film edge with lint-free towel wrapped around edge of a 5-way tool.

Bid Addendum 2/12/25

WINDOW FILM 088700-5

7. Upon completion of film application, allow 30 days for moisture from film installation to dry thoroughly, and to allow film to dry flat with no moisture dimples when viewed under normal viewing conditions.

8. If completing an exterior application, check with the manufacturer as to whether edge sealing is required.

3.4 CLEANING AND PROTECTION

A. Remove left over material and debris from Work area. Use necessary means to protect film before, during, and after installation.

B. Touch-up, repair or replace damaged products before Substantial Completion.

C. After application of film, wash film using common window cleaning solutions, including ammonia solutions, 30 days after application. Do not use abrasive type cleaning agents and bristle brushes to avoid scratching film. Use synthetic sponges or soft cloths.

END OF SECTION

File details come from the government source that posted it. Updated .