This is an architectural drawing showing typical roof details for the Armed Forces Retirement Home Sheridan Building renovation project in Washington DC. The drawing (A560) includes nine detailed technical illustrations of various roofing components and assemblies, including roof drains, pipe penetrations, expansion joints, and parapet connections.
The details specify construction requirements such as 3-ply modified bitumen roofing, minimum R-26 rigid insulation with 1/4" per foot slope to drains, air and vapor barriers, and 2-hour fire-rated pre-compressed foam joints (EMSEAL DFR2). The drawing provides specific assembly requirements for standing seam metal roofing, green roof drainage systems, and roof anchor installations. Construction materials include pressure-treated wood blocking, metal flashings, gypsum board, and waterproofing membranes. The drawing was prepared by AE Works for construction bid documents dated November 13, 2024, with a bid addendum issued February 12, 2025.
View the file
Other files
Show 40 more
Latest 50 of 90 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOF DRAIN
WATER CUT OFF MASTIC
ROOF STRUCTURE, REFER
TO STRUCTURAL DRAWINGS
CLAMPING RING
3 PLY MODIFIED BITUMEN ROOFING
RAIN WATER CONDUCTOR
4" RIGID INSULATION (R-26 MIN)
- TAPER TO DRAIN
TAPERED RIGID INSULATION
- SLOPE 1/4" MIN PER FT FOR
POSITIVE SLOPE TO DRAINS
AIR & VAPOR BARRIER
MEMBRANE FLASHING
WATER CUT OFF MASTIC
PREMOLDED PIPE SEAL
EXISTING ROOF STRUCTURE TO REMAIN
CLAMPING RING
IN-SEAM SEALANT
MODIFIED BITUMEN SEALANT PER MANUF.
MIN 4" RIGID INSULATION (R-26 MIN)
FULLY ADHERED ROOF MEMBRANE
TAPERED RIGID INSULATION
- SLOPE 1/4" PER FT FOR POSITIVE SLOPE TO DRAINS
EXISTING PIPE TO REMAIN
3 PLY MODIFIED BITUMEN ROOFING
ADHERED FLASHING STRIP PER MOD BIT MFR
SHEET METAL COUNTERFLASHING
WITH SEALANT AT TOP EDGE
1' - 6" 1' - 6"
EDGE RETAINER
STONE BALLAST
SEPARATION FABRIC AND
DRAINAGE COMPOSITE
OVER WATERPROOFING
MEMBRANE
CLAMPING RING
R3 / R5
PERFORATED METAL ENCLOSURE
ROOF DRAIN
WATER CUT OFF MASTIC
MEMBRANE FLASHING
STAINLESS STEEL U-
BAR SAFETY ANCHOR
PIPE CLAMP AND
CAULKING PER
ROOFING MFR
GALVANIZED STEEL PIER
ROOFING - REFER TO
ROOF ASSEMBLY TYPES
STEEL BEAM -REFER TO
STRUCTURAL DRAWINGS
FLAT STOCK
REFER TO SPECIFICATIONS
FOR ADDITIONAL INFORMATION
PROTECTION BOARD
RIGID INSULATION (R-30 MIN)
AIR AND WATER BARRIER
STEEL DECK -REFER TO
STRUCTURAL DRAWINGS
O.S. COMPOSITION CLOSURE
RIDGE CAP
R2
REFER TO STRUCTURAL
DRAWINGS
R2
MYLAR COATED TAPE
WITH MYLAR FACING UP
EXPANSION JOINT CAP
WEBBED MASTIC
FLEXIBLE EXPANSION FLASH
PT WOOD BLOCKING
HAT SHAPE SUBGIRT
WEBBED MASTIC
2 LAYERS TYPE X
GYPSUM BOARD2 LAYERS TYPE X
GYPSUM BOARD EA SIDE
BATT INSULATION
2 HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN
EMSEAL DFR2
R1
PLATE WITH SLOTTED CONNECTION
REFER TO STRUCTURAL DWGS
METAL GUTTER
EXISTING ROOF
TO REMAIN
METAL FLASHING, EXTEND
OVER BACK OF GUTTER
PT WOOD BLOCKING
EXISTING PARAPET
TO REMAIN
PT WOOD BLOCKING
CFMF, REFER TO
STRUCTURAL DWGS
2HR SHAFT WALL, UL415,
REFER TO STRUCTURAL
DWGS
STEEL FRAMING, REFER
TO STRUCTURAL DWGS 2 HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN
EMSEAL DFR2
2" RIGID INSULATION
EXPANSION JOINT CAP
MYLAR COATED TAPE WITH
MYLAR FACING UP
WEBBED MASTIC
FLEXIBLE EXPANSION FLASH
WEBBED MASTIC
HAT SHAPE SUBGIRT
METAL FLASHING
CONTRACTOR TO COORDINATE
INSTALLATION OF PRE-
COMPRESSED FOAM JOINT WITH
INSTALLATION OF SHAFT WALL
LINER PANELS
REFER TO STRUCTURAL
DRAWINGS
R2
MYLAR COATED TAPE
WITH MYLAR FACING UP
ROOF EXPANSION JOINT.
BASIS OF DESIGN: EMSEAL ROOFJOINT
WEBBED MASTIC
PT WOOD BLOCKING
HAT SHAPE SUBGIRT
WEBBED MASTIC
METAL FLASHING
TAPERED RIGID
INSULATION
RIGID INSULATION
R-30 MIN
AIR & WATER
BARRIER
PROTECTION
BOARD
3 PLY MOD BID
ROOFING
CANT STRIP
MEMBRANE FLASHING - WRAP
UP AND OVER PARAPET
AIR & WATER BARRIER
2 LAYERS TYPE X
GYPSUM BOARD
REFER TO STRUCTURAL
DRAWINGS
2 LAYERS TYPE X
GYPSUM BOARD
2 HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN
EMSEAL DFR2
CLOSED CELL INSULATION
R1
PLATE WITH SLOTTED CONNECTION
REFER TO STRUCTURAL DWGS
METAL GUTTER
EXISTING ROOF
TO REMAIN
METAL FLASHING, EXTEND
OVER BACK OF GUTTER
PT WOOD BLOCKING
EXISTING PARAPET
TO REMAIN
CFMF, REFER TO
STRUCTURAL DWGS
2HR SHAFT WALL, UL415, REFER TO
STRUCTURAL DWGS
STEEL FRAMING, REFER
TO STRUCTURAL DWGS
2 HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN
EMSEAL DFR2
2" RIGID INSULATION
METAL FLASHING
CANT STRIP
MEMBRANE FLASHING - WRAP
UP AND OVER PARAPET
AIR & WATER BARRIER
ROOF EXPANSION JOINIT
BASIS OF DESIGN: EMSEAL ROOF JOINT
METAL PANEL SYSTEM
SUBGIRT SYSTEM
AIR & WATER BARRIER
1/2" GYPSUM SHEATHING
CLOSED CELL
INSULATION
CONTRACTOR TO COORDINATE
INSTALLATION OF PRE-COMPRESSED
FOAM JOINT WITH INSTALLATION OF
SHAFT WALL LINER PANELS
DATE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
CLIENT:
418 BEAVER STREET
SEWICKLEY, PA 15143
PH: 412.287.7333
www.aeworks.com
PROFESSIONAL:
COPYRIGHT 2024 BY AE WORKS LTD ALL RIGHTS RESERVED.
SUBMISSION:
CONSTRUCTION BID
DOCUMENTS
AE WORKS®
A u to d e s k D o c s
/A F
R H
-0
S h e ri d a n /A
F R
H -0
A R
C H
-2
.r v t
/1
/2
:5
:0
A
M
A560
AEW
JW
AFRH-033
TYPICAL ROOF DETAILS
AFRH SHERIDAN
RENOVATION
140 ROCK CREEK
CHURCH ROAD,
NORTHWEST,
WASHINGTON, DC
ARMED FORCES
RETIREMENT HOME -
WASHINGTON D.C.
11/13/24
1 1/2" = 1'-0"
TYPICAL ROOF DRAIN DETAIL AT MOD BIT ROOF
1 1/2" = 1'-0"
TYPICAL PIPE PENETRATION DETAIL
1 1/2" = 1'-0"
TYPICAL GREEN ROOF DRAIN DETAIL
1 1/2" = 1'-0"
TYPICAL ROOF ANCHOR DETAIL
NO DATE REVISION
1 02/12/2025 BID ADDENDUM
1 1/2" = 1'-0"
RIDGE DETAIL AT STANDING SEAM ROOF
1 1/2" = 1'-0"
TYPICAL EXPANSION JOINT AT STANDING SEAM ROOF
1 1/2" = 1'-0"
SECTION DETAIL AT JOINT AT ROOF AND PARAPET
1 1/2" = 1'-0"
EXPANSION JOINT AT STANDING SEAM ROOF AND MTL PANEL WALL
1 1/2" = 1'-0"
SECTION DETAIL AT JOINT AT ROOF AND MTL PANEL WALL