About this file

This is an architectural drawing showing typical roof details for the Armed Forces Retirement Home Sheridan Building renovation project in Washington DC. The drawing (A560) includes nine detailed technical illustrations of various roofing components and assemblies, including roof drains, pipe penetrations, expansion joints, and parapet connections.

The details specify construction requirements such as 3-ply modified bitumen roofing, minimum R-26 rigid insulation with 1/4" per foot slope to drains, air and vapor barriers, and 2-hour fire-rated pre-compressed foam joints (EMSEAL DFR2). The drawing provides specific assembly requirements for standing seam metal roofing, green roof drainage systems, and roof anchor installations. Construction materials include pressure-treated wood blocking, metal flashings, gypsum board, and waterproofing membranes. The drawing was prepared by AE Works for construction bid documents dated November 13, 2024, with a bid addendum issued February 12, 2025.

View the file

Other files

File Type Posted
Amendment 0006 Solicitation 47PM0325R0002 2025 03 25.pdf PDF
Amendment 0005 RFI Responses 150 - 336 2025 03 18.pdf PDF
Amendment 0005 Solicitation 47PM0325R0002 2025 03 18 (2).pdf PDF
Amendment 0004 Solicitation 47PM0325R0002 2025 03 13.pdf PDF
H103 - CHILLER PLANT.pdf PDF
Amendment 0003 Technical Evaluation Factors-Best Value_ Trade Off 2025 03 04.pdf PDF
Amendment 0003 Solicitation 47PM0325R0002 2025 03 04.pdf PDF
A517 - EXTERIOR PLAN DETAILS.pdf PDF
A516 - EXTERIOR PLAN DETAILS.pdf PDF
087113 - Automatic Door Operator.pdf PDF
079500 - Exterior Expansion Control.pdf PDF
A427 - SPA ROOMS AND LAUNDRY ROOMS.pdf PDF
084113 - Aluminum-Framed Entrances and Storefronts.pdf PDF
A406 - CLINICAL AREAS- NURSE STATIONS - FIRST FLOOR.pdf PDF
AD100A - BASEMENT DEMOLITION PLAN A.pdf PDF
Amendment 0003 Solicitation_GC AFRH 2025 03 04.pdf PDF
236416 FL - Centrifugal Water Chillers- Addendum 3.pdf PDF
AI407 - TYPICAL ELEVATOR LOBBY FINISH PLANS AND ELEVATIONS (FLOORS 2-7).pdf PDF
107113 - Exterior Sun Control Devices.pdf PDF
088700 - Window Film.pdf PDF
AD100B - BASEMENT DEMOLITION PLAN B.pdf PDF
A405 - CLINICAL AREAS-NURSE STATIONS - FIRST FLOOR.pdf PDF
HD103 - CHILLER PLANT DEMO PLAN.pdf PDF
AI408 - TYPICAL NORTH- SOUTH ELEVATOR LOBBY FINISH PLANS (FLOORS 2-7).pdf PDF
A409 - ENLARGED TOILET ROOM PLANS AND ELEVATIONS.pdf PDF
087100 - Door Hardware.pdf PDF
101423.16 - Panel Signage.pdf PDF
A504 - EXTERIOR WALL SECTION DETAILS.pdf PDF
000110 Table of Contents.pdf PDF
H603 - HVAC DETAILS.pdf PDF
AFRH-Sheridan Pre-Bid Addendum 2-12-25.pdf PDF
081416 - Flush Wood Doors.pdf PDF
A601 - DOOR SCHEDULE TYPES DETAILS.pdf PDF
S542 - STRUCTURAL BALCONY ENCLOSURE DETAILS.pdf PDF
A503 - EXTERIOR WALL SECTION DETAILS.pdf PDF
A602 - DOOR SCHEDULE TYPES DETAILS.pdf PDF
S521 - STRUCTURAL ANNEX FRAMING DETAILS.pdf PDF
095000 - Wood Panel Ceiling.pdf PDF
S552 - STRUCTURAL TRASH CHUTE GENERATOR ENCLSOURE BALCONY ENCLOSURE DETAILS.pdf PDF
Amendment 0003 RFI Responses 1-149 2025 03 04.pdf PDF
235700 FL - Heat Exchangers for HVAC.pdf PDF
S401 - STRUCTURAL ROOF FRAMING PARTIAL PLANS.pdf PDF
Amendment 0003 Solicitation 47PM0325R0002 2025 03 04.pdf PDF
H804 - CONTROL DIAGRAMS.pdf PDF
AEWLA22050. Geotechnical Report. 10142022.pdf PDF
A412 - ENLARGED RESIDENT ROOM SHOWERS.pdf PDF
089119 - Fixed Louvers.pdf PDF
A112B - SECOND FLOOR REFLECTED CEILING PLAN B.pdf PDF
AI406 - FIRST FLOOR TOILET ROOM FINISH PLANS AND ELEVATIONS.pdf PDF
A102B - SECOND FLOOR PLAN B.pdf PDF
Show 40 more

Latest 50 of 90 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROOF DRAIN

WATER CUT OFF MASTIC

ROOF STRUCTURE, REFER

TO STRUCTURAL DRAWINGS

CLAMPING RING

3 PLY MODIFIED BITUMEN ROOFING

RAIN WATER CONDUCTOR

4" RIGID INSULATION (R-26 MIN)

- TAPER TO DRAIN

TAPERED RIGID INSULATION

- SLOPE 1/4" MIN PER FT FOR

POSITIVE SLOPE TO DRAINS

AIR & VAPOR BARRIER

MEMBRANE FLASHING

WATER CUT OFF MASTIC

PREMOLDED PIPE SEAL

EXISTING ROOF STRUCTURE TO REMAIN

CLAMPING RING

IN-SEAM SEALANT

MODIFIED BITUMEN SEALANT PER MANUF.

MIN 4" RIGID INSULATION (R-26 MIN)

FULLY ADHERED ROOF MEMBRANE

TAPERED RIGID INSULATION

- SLOPE 1/4" PER FT FOR POSITIVE SLOPE TO DRAINS

EXISTING PIPE TO REMAIN

3 PLY MODIFIED BITUMEN ROOFING

ADHERED FLASHING STRIP PER MOD BIT MFR

SHEET METAL COUNTERFLASHING

WITH SEALANT AT TOP EDGE

1' - 6" 1' - 6"

EDGE RETAINER

STONE BALLAST

SEPARATION FABRIC AND

DRAINAGE COMPOSITE

OVER WATERPROOFING

MEMBRANE

CLAMPING RING

R3 / R5

PERFORATED METAL ENCLOSURE

ROOF DRAIN

WATER CUT OFF MASTIC

MEMBRANE FLASHING

STAINLESS STEEL U-

BAR SAFETY ANCHOR

PIPE CLAMP AND

CAULKING PER

ROOFING MFR

GALVANIZED STEEL PIER

ROOFING - REFER TO

ROOF ASSEMBLY TYPES

STEEL BEAM -REFER TO

STRUCTURAL DRAWINGS

FLAT STOCK

REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATION

PROTECTION BOARD

RIGID INSULATION (R-30 MIN)

AIR AND WATER BARRIER

STEEL DECK -REFER TO

STRUCTURAL DRAWINGS

O.S. COMPOSITION CLOSURE

RIDGE CAP

R2

REFER TO STRUCTURAL

DRAWINGS

R2

MYLAR COATED TAPE

WITH MYLAR FACING UP

EXPANSION JOINT CAP

WEBBED MASTIC

FLEXIBLE EXPANSION FLASH

PT WOOD BLOCKING

HAT SHAPE SUBGIRT

WEBBED MASTIC

2 LAYERS TYPE X

GYPSUM BOARD2 LAYERS TYPE X

GYPSUM BOARD EA SIDE

BATT INSULATION

2 HR FIRE RATED PRE-COMPRESSED

FOAM JOINT, BASIS OF DESIGN

EMSEAL DFR2

R1

PLATE WITH SLOTTED CONNECTION

REFER TO STRUCTURAL DWGS

METAL GUTTER

EXISTING ROOF

TO REMAIN

METAL FLASHING, EXTEND

OVER BACK OF GUTTER

PT WOOD BLOCKING

EXISTING PARAPET

TO REMAIN

PT WOOD BLOCKING

CFMF, REFER TO

STRUCTURAL DWGS

2HR SHAFT WALL, UL415,

REFER TO STRUCTURAL

DWGS

STEEL FRAMING, REFER

TO STRUCTURAL DWGS 2 HR FIRE RATED PRE-COMPRESSED

FOAM JOINT, BASIS OF DESIGN

EMSEAL DFR2

2" RIGID INSULATION

EXPANSION JOINT CAP

MYLAR COATED TAPE WITH

MYLAR FACING UP

WEBBED MASTIC

FLEXIBLE EXPANSION FLASH

WEBBED MASTIC

HAT SHAPE SUBGIRT

METAL FLASHING

CONTRACTOR TO COORDINATE

INSTALLATION OF PRE-

COMPRESSED FOAM JOINT WITH

INSTALLATION OF SHAFT WALL

LINER PANELS

REFER TO STRUCTURAL

DRAWINGS

R2

MYLAR COATED TAPE

WITH MYLAR FACING UP

ROOF EXPANSION JOINT.

BASIS OF DESIGN: EMSEAL ROOFJOINT

WEBBED MASTIC

PT WOOD BLOCKING

HAT SHAPE SUBGIRT

WEBBED MASTIC

METAL FLASHING

TAPERED RIGID

INSULATION

RIGID INSULATION

R-30 MIN

AIR & WATER

BARRIER

PROTECTION

BOARD

3 PLY MOD BID

ROOFING

CANT STRIP

MEMBRANE FLASHING - WRAP

UP AND OVER PARAPET

AIR & WATER BARRIER

2 LAYERS TYPE X

GYPSUM BOARD

REFER TO STRUCTURAL

DRAWINGS

2 LAYERS TYPE X

GYPSUM BOARD

2 HR FIRE RATED PRE-COMPRESSED

FOAM JOINT, BASIS OF DESIGN

EMSEAL DFR2

CLOSED CELL INSULATION

R1

PLATE WITH SLOTTED CONNECTION

REFER TO STRUCTURAL DWGS

METAL GUTTER

EXISTING ROOF

TO REMAIN

METAL FLASHING, EXTEND

OVER BACK OF GUTTER

PT WOOD BLOCKING

EXISTING PARAPET

TO REMAIN

CFMF, REFER TO

STRUCTURAL DWGS

2HR SHAFT WALL, UL415, REFER TO

STRUCTURAL DWGS

STEEL FRAMING, REFER

TO STRUCTURAL DWGS

2 HR FIRE RATED PRE-COMPRESSED

FOAM JOINT, BASIS OF DESIGN

EMSEAL DFR2

2" RIGID INSULATION

METAL FLASHING

CANT STRIP

MEMBRANE FLASHING - WRAP

UP AND OVER PARAPET

AIR & WATER BARRIER

ROOF EXPANSION JOINIT

BASIS OF DESIGN: EMSEAL ROOF JOINT

METAL PANEL SYSTEM

SUBGIRT SYSTEM

AIR & WATER BARRIER

1/2" GYPSUM SHEATHING

CLOSED CELL

INSULATION

CONTRACTOR TO COORDINATE

INSTALLATION OF PRE-COMPRESSED

FOAM JOINT WITH INSTALLATION OF

SHAFT WALL LINER PANELS

DATE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

CLIENT:

418 BEAVER STREET

SEWICKLEY, PA 15143

PH: 412.287.7333

www.aeworks.com

PROFESSIONAL:

COPYRIGHT 2024 BY AE WORKS LTD ALL RIGHTS RESERVED.

SUBMISSION:

CONSTRUCTION BID

DOCUMENTS

AE WORKS®

A u to d e s k D o c s

/A F

R H

-0

S h e ri d a n /A

F R

H -0

A R

C H

-2

.r v t

/1

/2

:5

:0

A

M

A560

AEW

JW

AFRH-033

TYPICAL ROOF DETAILS

AFRH SHERIDAN

RENOVATION

140 ROCK CREEK

CHURCH ROAD,

NORTHWEST,

WASHINGTON, DC

ARMED FORCES

RETIREMENT HOME -

WASHINGTON D.C.

11/13/24

1 1/2" = 1'-0"

TYPICAL ROOF DRAIN DETAIL AT MOD BIT ROOF

1 1/2" = 1'-0"

TYPICAL PIPE PENETRATION DETAIL

1 1/2" = 1'-0"

TYPICAL GREEN ROOF DRAIN DETAIL

1 1/2" = 1'-0"

TYPICAL ROOF ANCHOR DETAIL

NO DATE REVISION

1 02/12/2025 BID ADDENDUM

1 1/2" = 1'-0"

RIDGE DETAIL AT STANDING SEAM ROOF

1 1/2" = 1'-0"

TYPICAL EXPANSION JOINT AT STANDING SEAM ROOF

1 1/2" = 1'-0"

SECTION DETAIL AT JOINT AT ROOF AND PARAPET

1 1/2" = 1'-0"

EXPANSION JOINT AT STANDING SEAM ROOF AND MTL PANEL WALL

1 1/2" = 1'-0"

SECTION DETAIL AT JOINT AT ROOF AND MTL PANEL WALL

AC

JW