This file contains architectural design drawings showing exterior plan details for the Armed Forces Retirement Home Sheridan Building renovation project in Washington DC. The drawing (A517) specifically details three different wall transition configurations: 1) typical metal panel to existing limestone transition, 2) metal panel wall at wall intersection, and 3) typical metal panel wall at existing limestone wall.
The technical details show specifications for endwall trim, flashing, sealants, backer rods, and a 2-hour pre-compressed foam joint (EMSEAL DFR2). The drawings include precise measurements and installation requirements for contractors, particularly noting coordination needed between cladding, rigid insulation, and flashing installation. The document was prepared by AE Works (418 Beaver Street, Sewickley, PA) as part of the construction bid documents dated February 12, 2025.
View the file
Other files
Show 40 more
Latest 50 of 90 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W6
ENDWALL TRIM - MATCH ADJACENT
PANEL MATERIAL AND FINISH
SEALANT AND BACKER ROD
ENDWALL FLASHING
BACKER ROD AND SEALANT
W2 1"
G.6
W4
SEALANT AND BACKER ROD
ENDWALL FLASHING
ENDWALL TRIM - MATCH
ADJACENT PANEL
MATERIAL AND FINISH
REFER TO
ARCHITECTURAL PLANS
FOR WALL TYPE
E
SEALANT AND BACKER ROD
EXPANSION JOINT
ENDWALL FLASHING
ENDWALL TRIM - MATCH
ADJACENT PANEL MATERIAL
AND FINISH
FACE OF EXISTING
LIMESTONE PANEL TO
REMAIN
REFER TO
ARCHITECTURAL PLANS
FOR WALL TYPE
W4
2" 2HR PRE-COMPRESSED FOAM
JOINT, BASIS OF DESIGN EMSEAL
DFR2
CONTRACTOR TO COORDINATE
INSTALLATION OF PRE-COMPRESSED FOAM
JOINT WITH INSTALLATION OF CLADDING,
RIGID INSULATION AND FLASHING
N
DATE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
CLIENT:
418 BEAVER STREET
SEWICKLEY, PA 15143
PH: 412.287.7333
www.aeworks.com
PROFESSIONAL:
COPYRIGHT 2024 BY AE WORKS LTD ALL RIGHTS RESERVED.
SUBMISSION:
CONSTRUCTION BID
DOCUMENTS
AE WORKS®
A u to d e s k D o c s
/A F
R H
-0
S h e ri d a n /A
F R
H -0
A R
C H
-2
.r v t
/1
/2
:5
:0
A
M
A517
AEW
Checker
AFRH-033
EXTERIOR PLAN
DETAILS
AFRH SHERIDAN
RENOVATION
140 ROCK CREEK
CHURCH ROAD,
NORTHWEST,
WASHINGTON, DC
ARMED FORCES
RETIREMENT HOME -
WASHINGTON D.C.
11/13/24
1 1/2" = 1'-0"
TYPICAL METAL PANEL TO EXISTING LIMESTONE TRANSITION
1 1/2" = 1'-0"
METAL PANEL WALL AT WALL INTERSECTION
1 1/2" = 1'-0"
TYPICAL METAL PANEL WALL AT EXISTING LIMESTONE WALL
NO DATE REVISION
1 02/12/2025 BID ADDENDUM