About this file

This is an architectural drawing sheet (A504) showing detailed exterior wall section details for the Armed Forces Retirement Home Sheridan Building renovation project in Washington, DC. The sheet contains 15 detailed section drawings depicting various construction elements including green roof assemblies, structural separations, limestone additions, sliding entry door details, trellis beams, granite planters, and building interface conditions.

The drawings provide specific construction requirements including waterproofing membranes, fire-rated assemblies, flashing details, expansion joints, and material specifications. Key elements shown include 2-hour fire-rated pre-compressed foam joints (EMSEAL DFR2), TPO roofing membranes, stone ballast, metal panel systems, CMU walls, and various trim and flashing components. The details are drawn at scales of 1" = 1'-0" and 1-1/2" = 1'-0" and include both existing conditions to remain and new construction elements. The drawings were prepared by AE Works (418 Beaver Street, Sewickley, PA) as part of the construction bid documents dated February 2025.

View the file

Other files

File Type Posted
Amendment 0006 Solicitation 47PM0325R0002 2025 03 25.pdf PDF
Amendment 0005 RFI Responses 150 - 336 2025 03 18.pdf PDF
Amendment 0005 Solicitation 47PM0325R0002 2025 03 18 (2).pdf PDF
Amendment 0004 Solicitation 47PM0325R0002 2025 03 13.pdf PDF
H103 - CHILLER PLANT.pdf PDF
Amendment 0003 Technical Evaluation Factors-Best Value_ Trade Off 2025 03 04.pdf PDF
Amendment 0003 Solicitation 47PM0325R0002 2025 03 04.pdf PDF
A517 - EXTERIOR PLAN DETAILS.pdf PDF
A516 - EXTERIOR PLAN DETAILS.pdf PDF
087113 - Automatic Door Operator.pdf PDF
079500 - Exterior Expansion Control.pdf PDF
A427 - SPA ROOMS AND LAUNDRY ROOMS.pdf PDF
084113 - Aluminum-Framed Entrances and Storefronts.pdf PDF
A406 - CLINICAL AREAS- NURSE STATIONS - FIRST FLOOR.pdf PDF
AD100A - BASEMENT DEMOLITION PLAN A.pdf PDF
Amendment 0003 Solicitation_GC AFRH 2025 03 04.pdf PDF
236416 FL - Centrifugal Water Chillers- Addendum 3.pdf PDF
AI407 - TYPICAL ELEVATOR LOBBY FINISH PLANS AND ELEVATIONS (FLOORS 2-7).pdf PDF
107113 - Exterior Sun Control Devices.pdf PDF
088700 - Window Film.pdf PDF
AD100B - BASEMENT DEMOLITION PLAN B.pdf PDF
A405 - CLINICAL AREAS-NURSE STATIONS - FIRST FLOOR.pdf PDF
HD103 - CHILLER PLANT DEMO PLAN.pdf PDF
AI408 - TYPICAL NORTH- SOUTH ELEVATOR LOBBY FINISH PLANS (FLOORS 2-7).pdf PDF
A409 - ENLARGED TOILET ROOM PLANS AND ELEVATIONS.pdf PDF
087100 - Door Hardware.pdf PDF
101423.16 - Panel Signage.pdf PDF
000110 Table of Contents.pdf PDF
H603 - HVAC DETAILS.pdf PDF
AFRH-Sheridan Pre-Bid Addendum 2-12-25.pdf PDF
081416 - Flush Wood Doors.pdf PDF
A601 - DOOR SCHEDULE TYPES DETAILS.pdf PDF
S542 - STRUCTURAL BALCONY ENCLOSURE DETAILS.pdf PDF
A560 - TYPICAL ROOF DETAILS.pdf PDF
A503 - EXTERIOR WALL SECTION DETAILS.pdf PDF
A602 - DOOR SCHEDULE TYPES DETAILS.pdf PDF
S521 - STRUCTURAL ANNEX FRAMING DETAILS.pdf PDF
095000 - Wood Panel Ceiling.pdf PDF
S552 - STRUCTURAL TRASH CHUTE GENERATOR ENCLSOURE BALCONY ENCLOSURE DETAILS.pdf PDF
Amendment 0003 RFI Responses 1-149 2025 03 04.pdf PDF
235700 FL - Heat Exchangers for HVAC.pdf PDF
S401 - STRUCTURAL ROOF FRAMING PARTIAL PLANS.pdf PDF
Amendment 0003 Solicitation 47PM0325R0002 2025 03 04.pdf PDF
H804 - CONTROL DIAGRAMS.pdf PDF
AEWLA22050. Geotechnical Report. 10142022.pdf PDF
A412 - ENLARGED RESIDENT ROOM SHOWERS.pdf PDF
089119 - Fixed Louvers.pdf PDF
A112B - SECOND FLOOR REFLECTED CEILING PLAN B.pdf PDF
AI406 - FIRST FLOOR TOILET ROOM FINISH PLANS AND ELEVATIONS.pdf PDF
A102B - SECOND FLOOR PLAN B.pdf PDF
Show 40 more

Latest 50 of 90 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECOND FLOOR

14' - 0"

BASE TRIM - MATCH ADJACENT PANEL MATERIAL AND

FINISH

METAL FLASHING - EXTEND TO COVER OVER

TERMINATION BAR

TPO AND FLASHING MEMBRANE- WRAP UP EDGE OF

RETAINING ANGLE

STONE BALLAST

SEPARATION FABRIC AND DRAINAGE COMPOSITE OVER

WATERPROOFING AND FLASHING MEMBRANE

EDGE RETAINER

METAL CLOSURE ANGLE

ROOF EXPANSION JOINT.

BASIS OF DESIGN: EMSEAL ROOFJOINT

SEALANT AS REQUIRED BY ROOF

JOINT MFR

METAL FLASHING WITH SEALANT

PT WOOD BLOCKING

WRAP AIR AND WATER BARRIER UP OVER PT

BLOCKING

R5

REFER TO DETAIL

FOR CONTINUATION OF DETAIL

/2 A505

METAL FLASHING

SELF-ADHERED MEMBRANE

FLASHING STRIP

3" 2 HR FIRE RATED PRE-COMPRESSED

FOAM JOINT, BASIS OF DESIGN

EMSEAL DFR2

6" CMU CURB WITH SOLID TOP BLOCK

SAWCUT AT ANGLE PARALLEL TO BALCONY

SLAB, REFER TO STRUCT DWG

CONTRACTOR TO COORDINATE

INSTALLATION OF ROOF EXPANSION JOINT

WITH CLADDING AND RIGID INSULATION

FIRST FLOOR

0" (317.80')

LIMESTONE PANEL

- UTILIZE EXISTING STORED

LIMESTONE PANEL

W2

2'

V

IF

2'

/2

NOTE: REFER TO TYPICAL STONE

ATTACHMENT DETAILS FOR

ADDITIONAL INFORMATION

FIRST FLOOR

0" (317.80')

GRAVEL BASE

RIGID INSULATION TO

5'-0" TO SLAB EDGE

CONT VAPOR BARRIER

JOINT SEALANT

SLIDING ENTRY DOOR WITH

INTEGRATED TRANSOM

-REFER TO DOOR SCHEDULE

METAL THRESHOLD SET IN

SEALANT BEDCONCRETE FOOR SLAB

-REFER TO STRUCTURAL DWGS

2" RIGID INSULATION

METAL FLASHING

WATERPROOFING

MEMBRANE, LAP AT

CONCRETE SILL AND OVER

VAPR BARRIER BELOW

METAL PANEL SYSTEM

PANEL END TRIM - MATCH ADJACENT

PANEL MATERIAL AND FINISH

METAL FLASHING

SEALANT AND BACKER ROD

SEALANT

FINISH CEILING

CFMF BOX BEAM

CLOSED CELL INSULATION

AIR AND WATER BARRIER

1/2" GYPSUM SHEATHING

RIGID INSULATION

1' - 6"

1'

1/4" / 1'-0"

COPING TRIM

-MATCH ADJACENT PANEL

MATERIAL AND FINISH

PT WOOD BLOCKING

METAL DECK

STEEL BEAM

-REFER TO STRUCTURAL DWGS

PT WOOD BLOCKING

CFMF

AIR & WATER BARRIER

1/2" GYPSUM SHEATHING

OUTSIDE CORNER TRIM

-MATCH ADJACENT PANEL

MATERIAL AND FINISH

METAL PANEL SYSTEM

ON SUBGIRTS

1' - 9"

1'

1/4" / 1'-0"

COPING TRIM

-MATCH ADJACENT PANEL

MATERIAL AND FINISH

PT WOOD BLOCKING

METAL DECK

PT WOOD BLOCKING

STEEL BEAM

-REFER TO STRUCTURAL DWGS

CFMF

AIR & WATER BARRIER

1/2" GYPSUM SHEATHING

OUTSIDE CORNER TRIM

-MATCH ADJACENT PANEL

MATERIAL AND FINISH

METAL PANEL SYSTEM

ON SUBGIRTS

METAL DECK

COPING TRIM

-MATCH ADJACENT PANEL

MATERIAL AND FINISH

AIR & WATER BARRIER

1/2" GYPSUM SHEATHING

CFMF

STEEL BEAM

-REFER TO STRUCTURAL DWGS

PT WOOD BLOCKING 1/4" / 1'-0"

OUTSIDE CORNER TRIM

- MATCH ADJACENT PANEL

MATERIAL AND FINISH

2' - 10"

1'

METAL PANEL

SYSTEM

ON SUBGIRTS

FIELD DRILL WEEPS

METAL FLASHING

SELF-ADHERED MEMBRANE

FLASHING STRIP

FIRST FLOOR

0" (317.80')

CONCRETE PIER CAP /

GRADE BEAM - REFER TO

STRUCTURAL DWGS

8" CMU

GRANITE PANEL

FACE OF METAL PANEL

AT COLUMN BEYOND

1'

1'

1' - 4"

FACE OF GRANITE PANEL

AT COLUMN BEYOND

NOTE: REFER TO TYPICAL

STONE ATTACHMENT

DETAILS FOR ADDITIONAL

INFORMATION1/4" / 1'-0"

WATERPROOFING

MEMBRANE

PROVIDE SEALANT AT

ALL EXPOSED EDGES

FIRST FLOOR

0" (317.80')

2HR FIRE RATED PRE-

COMPRESSED FOAM JOINT,

BASIS OF DESIGN EMSEAL

DFR2

EXPANSION JOINT

BELLOWS FLASHING

SEALANT AS REQUIRED BY

EXPANSION JOINT

BELLOWS FLASHING MFR

PT WOOD BLOCKING

METAL FLASHING WITH

DRIP EDGE

SEALANT

MEMBRANE FLASHING

- WRAP UP OVER CURB

CANT STRIP

R6

8" M

IN

METAL COUNTER FLASHING

WITH REGLET AND

SEALANT

W2

2 HR FIRE SPRAY AT BEAMS

UL DESIGN # D743

1 HR FIRE SPRAY AT ROOF

AND SECONDARY

SUPPORTING MEMBERS

UL DESIGN # D743

EXISTING CONCRETE

BEAM TO REMAIN

SEALANT AS REQUIRED BY

EXPANSION JOINT

BELLOWS FLASHING MFR

AIR AND WATER BARRIER

ROOF EXPANSION JOINT.

BASIS OF DESIGN: EMSEAL

ROOFJOINT

FIRST FLOOR

0" (317.80')

SECOND FLOOR

14' - 0"

C.5

EXISTING CONCRETE

BALCONY SLAB TO REMAIN

STEEL BEAM - REFER TO

STRUCTURAL DWGS

STEEL BEAM - REFER TO

STRUCTURAL DWGS

CONCRETE SLAB - REFER TO

STRUCTURAL DWGS

3'

1'

1"

SOFFIT BACK TRIM

- MATCH ADJACENT PANEL

MATERIAL AND FINISH

BACKUP Z CLIP

W4

METAL PANEL SYSTEM

METAL SUBGIRT SYSTEM

AIR & WATER BARRIER

1/2" GYPSUM SHEATHING

CFMF - REFER TO

STRUCTURAL DWGS

OUTSIDE CORNER TRIM

- MATCH ADJACENT PANEL

MATERIAL AND FINISH

BACKUP Z CLIP

CFMF

1/2" GYPSUM SHEATHING

AIR & WATER BARRIER

3" RIGID INSULATION

SUBGIRT SYSTEM

SUBGIRT SYSTEM

CFMF

2 HR FIRE SPRAY AT BEAM

UL DESIGN # D743

2 HR FIRE SPRAY AT FLOOR ASSEMBLY,

UL DESIGN # D743

2 HR FIRE SPRAY AT BEAM,

UL DESIGN # D743

FINISH CEILING - REFER TO

REFLECTED CEILING PLANS

BASE - REFER TO FINISH PLANS

FINISH FLOOR - REFER TO

FINISH PLANS

FINISH FLOOR - REFER TO

FINISH PLANS

FIELD DRILL WEEP

METAL FLASHING

EXISTING LIMESTONE PANEL

TO REMAIN

SEALANT WITH BACKER ROD

ENDWALL TRIM - MATCH ADJACENT

PANEL MATERIAL AND FINISH

3" RIGID INSULATION

AIR & WATER BARRIER

GYPSUM SHEATHING

CFMF - REFER TO

STRUCT. DWGS

PROVIDE AIR & WATER BARRIER

FOR PROTECTION OF WALL

DURING CONSTRUCTION

PROVIDE WATERPROOFING FOR

PROTECTION OF WALL SLAB AND

FOUNDATION WALL DURING

CONSTRUCTION

REMOVE EXISTING STONE

PANELS AS INDICATED ON DEMO

PLANS

EXISTING CMU WALL

TO REMAIN

DEMO EXISTING SLAB AS INDICATED

IN STRUCTURAL DRAWINGS

INTERIOR PARTITION, REFER TO

FLOOR PLANS

CMU INFILL, GROUT SOLID

EXISTING CMU WALL

CONCRETE SLAB, REFER TO

STRUCTURAL DRAWINGS

JOINT SEALANT

FINISH FLOOR, REFER

TO FINISH SCHEDULE

WALL BASE, REFER TO

FINISH SCHEDULE

SECOND FLOOR

14' - 0"

8" M

IN

R3

ROOF EXPANSION JOINT

BASIS OF DESIGN:

EMSEAL ROOF JOINT

3" 2 HR FIRE RATED

PRE-COMPRESSED FOAM JOINT,

BASIS OF DESIGN EMSEAL DFR2

6" CMU CURB WITH SOLID TOP

BLOCK SAWCUT AT ANGLE

PARALLEL TO BALCONY

SLAB, REFER TO STRUCT DWG

WRAP AIR AND WATER BARRIER

UP OVER PT BLOCKING

PT WOOD BLOCKING

CANT STRIP

MEMBRANE FLASHING

- WRAP UP OVER CURB

SEALANT

METAL FLASHING

WITH DRIP EDGE

SEALANT AS REQUIRED BY

EXPANSION JOINT BELLOWS

FLASHING MFR

EXPANSION JOINT BELLOWS

FLASHING

METAL FLASHING

BASE TRIM - MATCH ADJACENT PANEL MATERIAL AND

FINISH

METAL FLASHING - EXTEND TO COVER OVER

TERMINATION BAR

TPO AND FLASHING MEMBRANE- WRAP UP EDGE OF

RETAINING ANGLE

STONE BALLAST

SEPARATION FABRIC AND DRAINAGE COMPOSITE OVER

WATERPROOFING AND FLASHING MEMBRANE

EDGE RETAINER

ROOF EXPANSION JOINT.

BASIS OF DESIGN: EMSEAL ROOFJOINT

SEALANT AS REQUIRED BY ROOF

JOINT MFR

METAL FLASHING WITH SEALANT

PT WOOD BLOCKING

WRAP AIR AND WATER BARRIER UP OVER PT

BLOCKING

R5

REFER TO DETAIL

FOR CONTINUATION OF DETAIL

METAL FLASHING

SELF-ADHERED MEMBRANE

FLASHING STRIP

3" 2 HR FIRE RATED PRE-COMPRESSED

FOAM JOINT, BASIS OF DESIGN

EMSEAL DFR2

6" CMU CURB WITH SOLID TOP BLOCK

SAWCUT AT ANGLE PARALLEL TO BALCONY

SLAB, REFER TO STRUCT DWG

ALIGN

CONTRACTOR TO COORDINATE

INSTALLATION OF ROOF EXPANSION JOINT

WITH CLADDING AND RIGID INSULATION

DATE:

DRAWN BY:

CHECKED BY:

PROJ. NO:

DRAWING NO:

DRAWING TITLE:

PROJECT NAME:

CLIENT:

418 BEAVER STREET

SEWICKLEY, PA 15143

PH: 412.287.7333

www.aeworks.com

PROFESSIONAL:

COPYRIGHT 2024 BY AE WORKS LTD ALL RIGHTS RESERVED.

SUBMISSION:

CONSTRUCTION BID

DOCUMENTS

AE WORKS®

A u to d e s k D o c s

/A F

R H

-0

S h e ri d a n /A

F R

H -0

A R

C H

-2

.r v t

/1

/2

:5

:5

A

M

A504

AEW

Checker

AFRH-033

EXTERIOR WALL

SECTION DETAILS

AFRH SHERIDAN

RENOVATION

140 ROCK CREEK

CHURCH ROAD,

NORTHWEST,

WASHINGTON, DC

ARMED FORCES

RETIREMENT HOME -

WASHINGTON D.C.

11/13/241" = 1'-0"

N-S SECTION DTL AT GREEN ROOF AND STRUCTURAL SEPARATION

1" = 1'-0"

SECTION DETAIL AT LIMESTONE ADDITION

1" = 1'-0"

SLIDING ENTRY DOOR THRESHOLD DETAIL

1" = 1'-0"

SLIDING ENTRY DOOR TRANSOM HEAD DETAIL

3/4" = 1'-0"

SECTION DETAIL AT TRELLIS TYPICAL BEAM

3/4" = 1'-0"

SECTION DETAIL AT TRELLIS END BEAM

1" = 1'-0"

SECTION DETAIL AT TRELLIS FRONT BEAM

1" = 1'-0"

SECTION DETAIL AT GRANITE PLANTER

1" = 1'-0"

SECTION DETAIL AT ROOF AND EXISTING FACADE

1" = 1'-0"

SECTION DETAIL AT BRIDGE

1" = 1'-0"

SECTION DETAIL AT SOFFIT AND EXISTING WALL

1 1/2" = 1'-0"

DEMO SECTION DETAIL AT BUILDING INTERFACE

1 1/2" = 1'-0"

SECTION DETAIL AT BUILDING INTERFACE

NO DATE REVISION

1 02/12/2025 BID ADDENDUM

1" = 1'-0"

SECTION DETAIL AT ROOF

1" = 1'-0"

E-W SECTION DTL AT GREEN ROOF AND STRUCTURAL SEPARATION

AC

JW

File details come from the government source that posted it. Updated .