This is an architectural drawing sheet (A504) showing detailed exterior wall section details for the Armed Forces Retirement Home Sheridan Building renovation project in Washington, DC. The sheet contains 15 detailed section drawings depicting various construction elements including green roof assemblies, structural separations, limestone additions, sliding entry door details, trellis beams, granite planters, and building interface conditions.
The drawings provide specific construction requirements including waterproofing membranes, fire-rated assemblies, flashing details, expansion joints, and material specifications. Key elements shown include 2-hour fire-rated pre-compressed foam joints (EMSEAL DFR2), TPO roofing membranes, stone ballast, metal panel systems, CMU walls, and various trim and flashing components. The details are drawn at scales of 1" = 1'-0" and 1-1/2" = 1'-0" and include both existing conditions to remain and new construction elements. The drawings were prepared by AE Works (418 Beaver Street, Sewickley, PA) as part of the construction bid documents dated February 2025.
View the file
Other files
Show 40 more
Latest 50 of 90 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECOND FLOOR
14' - 0"
BASE TRIM - MATCH ADJACENT PANEL MATERIAL AND
FINISH
METAL FLASHING - EXTEND TO COVER OVER
TERMINATION BAR
TPO AND FLASHING MEMBRANE- WRAP UP EDGE OF
RETAINING ANGLE
STONE BALLAST
SEPARATION FABRIC AND DRAINAGE COMPOSITE OVER
WATERPROOFING AND FLASHING MEMBRANE
EDGE RETAINER
METAL CLOSURE ANGLE
ROOF EXPANSION JOINT.
BASIS OF DESIGN: EMSEAL ROOFJOINT
SEALANT AS REQUIRED BY ROOF
JOINT MFR
METAL FLASHING WITH SEALANT
PT WOOD BLOCKING
WRAP AIR AND WATER BARRIER UP OVER PT
BLOCKING
R5
REFER TO DETAIL
FOR CONTINUATION OF DETAIL
/2 A505
METAL FLASHING
SELF-ADHERED MEMBRANE
FLASHING STRIP
3" 2 HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN
EMSEAL DFR2
6" CMU CURB WITH SOLID TOP BLOCK
SAWCUT AT ANGLE PARALLEL TO BALCONY
SLAB, REFER TO STRUCT DWG
CONTRACTOR TO COORDINATE
INSTALLATION OF ROOF EXPANSION JOINT
WITH CLADDING AND RIGID INSULATION
FIRST FLOOR
0" (317.80')
LIMESTONE PANEL
- UTILIZE EXISTING STORED
LIMESTONE PANEL
W2
2'
V
IF
2'
/2
NOTE: REFER TO TYPICAL STONE
ATTACHMENT DETAILS FOR
ADDITIONAL INFORMATION
FIRST FLOOR
0" (317.80')
GRAVEL BASE
RIGID INSULATION TO
5'-0" TO SLAB EDGE
CONT VAPOR BARRIER
JOINT SEALANT
SLIDING ENTRY DOOR WITH
INTEGRATED TRANSOM
-REFER TO DOOR SCHEDULE
METAL THRESHOLD SET IN
SEALANT BEDCONCRETE FOOR SLAB
-REFER TO STRUCTURAL DWGS
2" RIGID INSULATION
METAL FLASHING
WATERPROOFING
MEMBRANE, LAP AT
CONCRETE SILL AND OVER
VAPR BARRIER BELOW
METAL PANEL SYSTEM
PANEL END TRIM - MATCH ADJACENT
PANEL MATERIAL AND FINISH
METAL FLASHING
SEALANT AND BACKER ROD
SEALANT
FINISH CEILING
CFMF BOX BEAM
CLOSED CELL INSULATION
AIR AND WATER BARRIER
1/2" GYPSUM SHEATHING
RIGID INSULATION
1' - 6"
1'
1/4" / 1'-0"
COPING TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
PT WOOD BLOCKING
METAL DECK
STEEL BEAM
-REFER TO STRUCTURAL DWGS
PT WOOD BLOCKING
CFMF
AIR & WATER BARRIER
1/2" GYPSUM SHEATHING
OUTSIDE CORNER TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
METAL PANEL SYSTEM
ON SUBGIRTS
1' - 9"
1'
1/4" / 1'-0"
COPING TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
PT WOOD BLOCKING
METAL DECK
PT WOOD BLOCKING
STEEL BEAM
-REFER TO STRUCTURAL DWGS
CFMF
AIR & WATER BARRIER
1/2" GYPSUM SHEATHING
OUTSIDE CORNER TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
METAL PANEL SYSTEM
ON SUBGIRTS
METAL DECK
COPING TRIM
-MATCH ADJACENT PANEL
MATERIAL AND FINISH
AIR & WATER BARRIER
1/2" GYPSUM SHEATHING
CFMF
STEEL BEAM
-REFER TO STRUCTURAL DWGS
PT WOOD BLOCKING 1/4" / 1'-0"
OUTSIDE CORNER TRIM
- MATCH ADJACENT PANEL
MATERIAL AND FINISH
2' - 10"
1'
METAL PANEL
SYSTEM
ON SUBGIRTS
FIELD DRILL WEEPS
METAL FLASHING
SELF-ADHERED MEMBRANE
FLASHING STRIP
FIRST FLOOR
0" (317.80')
CONCRETE PIER CAP /
GRADE BEAM - REFER TO
STRUCTURAL DWGS
8" CMU
GRANITE PANEL
FACE OF METAL PANEL
AT COLUMN BEYOND
1'
1'
1' - 4"
FACE OF GRANITE PANEL
AT COLUMN BEYOND
NOTE: REFER TO TYPICAL
STONE ATTACHMENT
DETAILS FOR ADDITIONAL
INFORMATION1/4" / 1'-0"
WATERPROOFING
MEMBRANE
PROVIDE SEALANT AT
ALL EXPOSED EDGES
FIRST FLOOR
0" (317.80')
2HR FIRE RATED PRE-
COMPRESSED FOAM JOINT,
BASIS OF DESIGN EMSEAL
DFR2
EXPANSION JOINT
BELLOWS FLASHING
SEALANT AS REQUIRED BY
EXPANSION JOINT
BELLOWS FLASHING MFR
PT WOOD BLOCKING
METAL FLASHING WITH
DRIP EDGE
SEALANT
MEMBRANE FLASHING
- WRAP UP OVER CURB
CANT STRIP
R6
8" M
IN
METAL COUNTER FLASHING
WITH REGLET AND
SEALANT
W2
2 HR FIRE SPRAY AT BEAMS
UL DESIGN # D743
1 HR FIRE SPRAY AT ROOF
AND SECONDARY
SUPPORTING MEMBERS
UL DESIGN # D743
EXISTING CONCRETE
BEAM TO REMAIN
SEALANT AS REQUIRED BY
EXPANSION JOINT
BELLOWS FLASHING MFR
AIR AND WATER BARRIER
ROOF EXPANSION JOINT.
BASIS OF DESIGN: EMSEAL
ROOFJOINT
FIRST FLOOR
0" (317.80')
SECOND FLOOR
14' - 0"
C.5
EXISTING CONCRETE
BALCONY SLAB TO REMAIN
STEEL BEAM - REFER TO
STRUCTURAL DWGS
STEEL BEAM - REFER TO
STRUCTURAL DWGS
CONCRETE SLAB - REFER TO
STRUCTURAL DWGS
3'
1'
1"
SOFFIT BACK TRIM
- MATCH ADJACENT PANEL
MATERIAL AND FINISH
BACKUP Z CLIP
W4
METAL PANEL SYSTEM
METAL SUBGIRT SYSTEM
AIR & WATER BARRIER
1/2" GYPSUM SHEATHING
CFMF - REFER TO
STRUCTURAL DWGS
OUTSIDE CORNER TRIM
- MATCH ADJACENT PANEL
MATERIAL AND FINISH
BACKUP Z CLIP
CFMF
1/2" GYPSUM SHEATHING
AIR & WATER BARRIER
3" RIGID INSULATION
SUBGIRT SYSTEM
SUBGIRT SYSTEM
CFMF
2 HR FIRE SPRAY AT BEAM
UL DESIGN # D743
2 HR FIRE SPRAY AT FLOOR ASSEMBLY,
UL DESIGN # D743
2 HR FIRE SPRAY AT BEAM,
UL DESIGN # D743
FINISH CEILING - REFER TO
REFLECTED CEILING PLANS
BASE - REFER TO FINISH PLANS
FINISH FLOOR - REFER TO
FINISH PLANS
FINISH FLOOR - REFER TO
FINISH PLANS
FIELD DRILL WEEP
METAL FLASHING
EXISTING LIMESTONE PANEL
TO REMAIN
SEALANT WITH BACKER ROD
ENDWALL TRIM - MATCH ADJACENT
PANEL MATERIAL AND FINISH
3" RIGID INSULATION
AIR & WATER BARRIER
GYPSUM SHEATHING
CFMF - REFER TO
STRUCT. DWGS
PROVIDE AIR & WATER BARRIER
FOR PROTECTION OF WALL
DURING CONSTRUCTION
PROVIDE WATERPROOFING FOR
PROTECTION OF WALL SLAB AND
FOUNDATION WALL DURING
CONSTRUCTION
REMOVE EXISTING STONE
PANELS AS INDICATED ON DEMO
PLANS
EXISTING CMU WALL
TO REMAIN
DEMO EXISTING SLAB AS INDICATED
IN STRUCTURAL DRAWINGS
INTERIOR PARTITION, REFER TO
FLOOR PLANS
CMU INFILL, GROUT SOLID
EXISTING CMU WALL
CONCRETE SLAB, REFER TO
STRUCTURAL DRAWINGS
JOINT SEALANT
FINISH FLOOR, REFER
TO FINISH SCHEDULE
WALL BASE, REFER TO
FINISH SCHEDULE
SECOND FLOOR
14' - 0"
8" M
IN
R3
ROOF EXPANSION JOINT
BASIS OF DESIGN:
EMSEAL ROOF JOINT
3" 2 HR FIRE RATED
PRE-COMPRESSED FOAM JOINT,
BASIS OF DESIGN EMSEAL DFR2
6" CMU CURB WITH SOLID TOP
BLOCK SAWCUT AT ANGLE
PARALLEL TO BALCONY
SLAB, REFER TO STRUCT DWG
WRAP AIR AND WATER BARRIER
UP OVER PT BLOCKING
PT WOOD BLOCKING
CANT STRIP
MEMBRANE FLASHING
- WRAP UP OVER CURB
SEALANT
METAL FLASHING
WITH DRIP EDGE
SEALANT AS REQUIRED BY
EXPANSION JOINT BELLOWS
FLASHING MFR
EXPANSION JOINT BELLOWS
FLASHING
METAL FLASHING
BASE TRIM - MATCH ADJACENT PANEL MATERIAL AND
FINISH
METAL FLASHING - EXTEND TO COVER OVER
TERMINATION BAR
TPO AND FLASHING MEMBRANE- WRAP UP EDGE OF
RETAINING ANGLE
STONE BALLAST
SEPARATION FABRIC AND DRAINAGE COMPOSITE OVER
WATERPROOFING AND FLASHING MEMBRANE
EDGE RETAINER
ROOF EXPANSION JOINT.
BASIS OF DESIGN: EMSEAL ROOFJOINT
SEALANT AS REQUIRED BY ROOF
JOINT MFR
METAL FLASHING WITH SEALANT
PT WOOD BLOCKING
WRAP AIR AND WATER BARRIER UP OVER PT
BLOCKING
R5
REFER TO DETAIL
FOR CONTINUATION OF DETAIL
METAL FLASHING
SELF-ADHERED MEMBRANE
FLASHING STRIP
3" 2 HR FIRE RATED PRE-COMPRESSED
FOAM JOINT, BASIS OF DESIGN
EMSEAL DFR2
6" CMU CURB WITH SOLID TOP BLOCK
SAWCUT AT ANGLE PARALLEL TO BALCONY
SLAB, REFER TO STRUCT DWG
ALIGN
CONTRACTOR TO COORDINATE
INSTALLATION OF ROOF EXPANSION JOINT
WITH CLADDING AND RIGID INSULATION
DATE:
DRAWN BY:
CHECKED BY:
PROJ. NO:
DRAWING NO:
DRAWING TITLE:
PROJECT NAME:
CLIENT:
418 BEAVER STREET
SEWICKLEY, PA 15143
PH: 412.287.7333
www.aeworks.com
PROFESSIONAL:
COPYRIGHT 2024 BY AE WORKS LTD ALL RIGHTS RESERVED.
SUBMISSION:
CONSTRUCTION BID
DOCUMENTS
AE WORKS®
A u to d e s k D o c s
/A F
R H
-0
S h e ri d a n /A
F R
H -0
A R
C H
-2
.r v t
/1
/2
:5
:5
A
M
A504
AEW
Checker
AFRH-033
EXTERIOR WALL
SECTION DETAILS
AFRH SHERIDAN
RENOVATION
140 ROCK CREEK
CHURCH ROAD,
NORTHWEST,
WASHINGTON, DC
ARMED FORCES
RETIREMENT HOME -
WASHINGTON D.C.
11/13/241" = 1'-0"
N-S SECTION DTL AT GREEN ROOF AND STRUCTURAL SEPARATION
1" = 1'-0"
SECTION DETAIL AT LIMESTONE ADDITION
1" = 1'-0"
SLIDING ENTRY DOOR THRESHOLD DETAIL
1" = 1'-0"
SLIDING ENTRY DOOR TRANSOM HEAD DETAIL
3/4" = 1'-0"
SECTION DETAIL AT TRELLIS TYPICAL BEAM
3/4" = 1'-0"
SECTION DETAIL AT TRELLIS END BEAM
1" = 1'-0"
SECTION DETAIL AT TRELLIS FRONT BEAM
1" = 1'-0"
SECTION DETAIL AT GRANITE PLANTER
1" = 1'-0"
SECTION DETAIL AT ROOF AND EXISTING FACADE
1" = 1'-0"
SECTION DETAIL AT BRIDGE
1" = 1'-0"
SECTION DETAIL AT SOFFIT AND EXISTING WALL
1 1/2" = 1'-0"
DEMO SECTION DETAIL AT BUILDING INTERFACE
1 1/2" = 1'-0"
SECTION DETAIL AT BUILDING INTERFACE
NO DATE REVISION
1 02/12/2025 BID ADDENDUM
1" = 1'-0"
SECTION DETAIL AT ROOF
1" = 1'-0"
E-W SECTION DTL AT GREEN ROOF AND STRUCTURAL SEPARATION
AC
JW