1-AE112 - PHASE A3 NEW WORK PLAN RFI 29 - 506-20-102.pdf
PDF 240 KB Posted
- Solicitation number
- 36C25023B0027
About this file
This document contains details for an upcoming federal contract opportunity to renovate basement spaces at the LTC Charles S. Kettles Veterans Administration Medical Center in Ann Arbor, Michigan. The project involves interior renovation of approximately 14,000 square feet, including upgrading mechanical, electrical, and plumbing systems as well as asbestos abatement. The work drawings provide specifications for new room layouts, equipment, and construction phasing. The pre-solicitation notice describes plans to issue an invitation for bid on or about March 20, 2023 seeking fixed price proposals for the renovation work. The total project cost is estimated between $1 million and $5 million. The opportunity is set aside exclusively for qualified Service-Disabled Veteran Owned Small Businesses. Responses are due according to the solicitation schedule to be published on SAM.gov in March, with award intended within 120 days of bid opening.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
F
U
S T
E Q
E Q
155 SF
FLAMMABLE
WASTE
STORAGE
AB37C
259 SF
SLIDE STORAGE
AB43
567 SF
NUCLEAR
WASTE
STORAGE
AB46
511 SF
SOUTH
CORRIDOR -
EAST
C1
6 7
9 9
10101010
21 1
2A
2A
2A
2A 2A
2A
2A2A
TYP.
TYP.
21' - 6" 11' - 3"
1-AE312
TYP.
TYP.
1-AE312
TYP. 3 PLACES
8' - 9" 5' - 6 1/2"
1-AE312
5 1-AE312
1-AE312
1 15
15 1
SIM.
SIM.
1-AE312
2A 2A 2A
2A
2A
2A
2B
2B
2A
PHASE A3
DEMOLISH EXISTING ROOMS AND ASSOCIATED ITEMS PER SHEET 1-AD112: CORRIDOR (C1),
STORAGE (AB39), MECHANICAL (AB42), RESTROOM (AB43), PRIVATE VISITATION ROOM (AB45), AUTOPSY ROOM (AB46), AUTOPSY OFFICE (AB48).
PROVIDE NEW ROOMS AND ASSOCIATED WORK PER SHEETS 1-AE113 AND 1-AC142: SOUTH
CORRIDOR – EAST, MISC. STORAGE, NUCLEAR WASTE STORAGE, SOUTH CORRIDOR – WEST.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
C U s e rs
\q u in n \D o c u m e n ts \A n n
A rb o r
B ld g
W B a s e m e n t (2 p a tr ic k .q u in n F
B N
E U
.r v t
/1
/2
:1
:2
P
M
1-AE112
PHASE A3 NEW WORK PLAN
01/13/2023 PQ JK
UPGRADE BASEMENT,
BUILDING 1 WEST
506-20-102
ANN ARBOR, MICHIGAN
BID DOCUMENTS
1W
ANN ARBOR VA
MEDICAL
CENTER Approved: Veteran's Affairs Medical Center
1 TEMPORARY CONSTRUCTION SIGNAGE - SEE DETAIL 4/GI003. INSTALL SIGNAGE TEMPORARILY
SECURED TO DOOR AT 5'-0" A.F.F. REMOVE AT CONCLUSION OF CONSTRUCTION PHASE.
2 6' CHEST FREEZER.
3 24" X 30" FLOOR SCALE (VV)
4 STAINLESS STEEL UTILITY SINK WITH GOOSENECK FAUCET - SEE PLUMBING DRAWINGS
5 3'-6" X 2'-0" FREE STANDING RACK (VV).
6 WALL MOUNTED PHONE - TOP AT 48" AFF. - SEE ELECTRICAL DRAWINGS
7 STAINLESS STEEL WORKSURFACE AT 32" A.F.F.
8 STAINLESS STEEL MOBILE SHELVING UNIT - 72" H X 24" D - 500 LB CAPACITY PER SHELF - ALL
SURFACES OF UNIT SHALL BE SMOOTH AND CONTINUOUS TO BE WIPEABLE AND FOR EASY
DECONTAMINATION - WIRE FRAME UNITS UNACCEPTABLE.
9 16" DEEP WALL MOUNTED SHELVING (VV).
10 (6) STACKED TRASH CANS (VV).
11 FIRE RATED DOOR ON HOLD OPENS.
12 KEYPAD ACCESS CONTROL - SEE ELECTRICAL AND TELECOMMUNICATIONS DRAWINGS.
13 FULLY RECESSED FIRE EXTINGUISHER CABINET WITH 10LBS ABC FIRE EXTINGUISHER.
14 EXHAUST THROUGH EXISTING OPENING. INFILL REMAINDER OF WALL - SEE MECHANICAL
DRAWINGS AND TYPICAL SECTION.
15 REMOVE SUSPENDED PLASTIC BARRIER WITH ZIPPER DOOR AT CONCLUSION OF PHASE.
16 PAPER TOWEL DISPENSER (VC).
17 SOAP DISPENSER (VC).
G E N E R A L N O T E S
A. NEW WALLS ARE SHOWN AS HATCHED.
B. SEE SHEET 1-AE101 FOR OVERALL NEW WORK AND PHASING PLAN.
C. CONTRACTOR SHALL VERIFY COOLER/FREEZER MANUFACTURE CLEARANCE
REQUIREMENTS. ALL COOLER/FREEZER DIMENSIONS ARE PLUS OR MINUS VERIFY IN FIELD.
D. ALL ITEMS ARE CONTRACTOR FURNISHED AND INSTALLED (CC) UNLESS NOTED OTHERWISE.
E. PHASE INSTALLATION OF CORRIDOR DOORS SO THAT EGRESS FROM THE DOCK TO THE
WEST CORRIDOR IS MAINTAINED AT ALL TIMES. CONTRACTOR SHALL NOT HAVE TEMPORARY
BARRIERS INSTALLED AT BOTH LOCATIONS AT THE SAME TIME.
F. ALL CONSTRUCTION WORK AREAS SHALL BE SEPARATED FROM PUBLIC AND STAFF AREAS.
UNLESS NOTED OTHERWISE ON DRAWINGS OR SPECIFICATIONS, PROVIDE FIRE-RETARDANT
SHEET PLASTIC SMOKE BARRIERS TO MEET INFECTION CONTROL REQUIREMENTS OF
SPECIFICATION SECTION 01 35 26 - SAFETY REQUIREMENTS.
G. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS UNLESS NOTED OTHERWISE.
H. ALL COLUMN WRAPS SHALL BE HELD NO MORE THAN 1/2" OFF COLUMNS UNLESS NOTED
OTHERWISE. REPORT TO C.O.R. AND ARCHITECT WHERE EXISTING CONDITIONS IMPACT
ABILITY TO COMPLY.
I. DASH PATTERNS ON WALLS INDICATE LEVELS OF FIRE RESISTANT CONSTRUCTION - SEE
SHEET GI001 FOR FIRE RATING.
J. ALL WORK SHALL FOLLOW ICRA LEVEL III REQUIREMENTS UNLESS NOTED OTHERWISE. ICRA
LEVEL IV REQUIREMENTS SHALL BE REQUIRED AT ASBESTOS ABATEMENT. SEE ASBESTOS
ABATEMENT SPECIFICATIONS FOR REQUIREMENTS.
KEYPLAN
D R A W I N G N O T E S
P H A S I N G N O T E S
1/4" = 1'-0"
ENLARGED NEW WORK PLAN - PHASE A3
P R O C U R E M E N T L E G E N D
(VV) - V.A. FURNISHED / V.A. INSTALLED
(VC) - V.A. FURNISHED / CONTRACTOR INSTALLED
(CC) - CONTRACTOR FURNISHED / CONTRACTOR INSTALLED
(R) - REUSED ITEM
3'-6" x 2'-0" FREE STANDING RACK VV 2
AB43, SLIDE STORAGE
RECESSED FIRE EXTINGUISHER CABINET CC 1
C1, SOUTH CORRIDOR - EAST
WALL MOUNTED PHONE CC 1
24" X 30" SCALE VV 1
CHEST FREEZER CC 1
WORKSURFACE CC 1
STACKS OF TRASH CANS VV 6
STAINLESS STEEL MOBILE SHELVING UNIT CC 3
3'-6" x 2'-0" FREE STANDING RACK VV 10
AB46, NUCLEAR WASTE STORAGE
EQUIPMENT PROCUREMENT QUANTITY
EQUIPMENT SCHEDULE PHASE A3
No. Revisions: Date:
BID DOCUMENTS 01/13/2023
1 ADDENDUM 02 05/17/2023
| Sheets |
| 1-AE112 - PHASE A3 NEW WORK PLAN |
| 1-AE114 - PHASE A5 NEW WORK PLAN |
File details come from the government source that posted it. Updated .