1696746_DWG_2of5.pdf

PDF 22 MB Posted

Attached to
JFY 2022 PROJECT J-875, BATTLE STAFF TRAINING FACILITY, U. S. NAVSUPPACT MCB CAMP BLAZ, GUAM
Solicitation number
N62742-26-R-1306
Issued by

About this file

This file comprises architectural construction drawings and design documents for the Battle Staff Training Facility (BSTF) at Marine Corps Base Camp Blaz, Guam. The project is a design-bid-build (DBB) contract (N62742-20-D-0001) under Naval Facilities Engineering Systems Command (NAVFAC) Pacific.

The facility consists of a two-story reinforced concrete building with approximately 55,701 square feet of floor area and 59,308 square feet of roof area, designed to accommodate the Third Marine Expeditionary Brigade Marine Air-Ground Task Force (MAGTF). Key architectural components include a two-floor structure with 16-foot floor-to-floor heights, fire-rated partition systems (STC 50-60 ratings), raised access flooring in designated areas, and comprehensive mechanical, electrical, and fire protection systems. The design incorporates multiple training and operational spaces including tactical operations centers, intelligence control cells, communications facilities, conference rooms, and support spaces. Support facilities shown in the drawings include a chiller enclosure, transformer enclosure, trash enclosure, generator and fuel tank enclosure (Option Item #2), and a pavilion structure (Option Item #1). The architectural documents include site plans, floor plans, reflected ceiling plans, exterior and interior elevations, wall sections, door and window schedules, partition type specifications, finish schedules, signage plans, and detailed specifications for fire protection systems (sprinkler and fire alarm/mass notification systems). The design must comply with Unified Facilities Criteria (UFC) standards, NFPA codes, and accommodate Guam's seismic and environmental conditions. Construction drawings are dated August 25, 2020 (revision date), with final approval signatures from March 10, 2026.

View the file

Other files

File Type Posted
26-1306 Note 12.pdf PDF
N62742-26-R-1306_AMD0006.pdf PDF
N62742-26-R-1306_AMD0005.pdf PDF
26-1306 Note 11.pdf PDF
Att1_1696746_Amd0005_DWGS_260605.pdf PDF
Att2_1696746_Amd0005_SPECS_260605.pdf PDF
N62742-26-R-1306_AMD0004.pdf PDF
26-1306 Note 10.pdf PDF
26-1306 Note 9.pdf PDF
26-1306 Note 8.pdf PDF
26-1306 Note 7.pdf PDF
26-1306 Note 6.pdf PDF
N62742-26-R-1306_AMD0003.pdf PDF
26-1306 Note 5.pdf PDF
26-1306 Note 4.pdf PDF
Att1_1696746Amd0002dwg_260515r1_Signed.pdf PDF
Att2_1696746Amd0002spc_260515r1.pdf PDF
N62742-26-R-1306_AMD0002.pdf PDF
26-1306 Note 3.pdf PDF
26-1306 Note 2.pdf PDF
26-1306 Note 1.pdf PDF
N62742-26-R-1306_AMD0001.pdf PDF
Class JA King-Fisher Guam redact.pdf PDF
Class JA_Federal Signal_Redacted.pdf PDF
Schn_AMI_CJA_red.pdf PDF
CJA_JCI DDC_Red.pdf PDF
MCBG Knox Box Class JA_Redacted.pdf PDF
Solicitation-N6274226R1306.pdf PDF
1696746_SPC.pdf PDF
1696746_DWG_1of5.pdf PDF
1696746_DWG_3of5.pdf PDF
1696746_DWG_4of5.pdf PDF
ECC_CJA_Red.pdf PDF
1696746_DWG_5of5.pdf PDF
CJA_KabaMas GPMO_13Feb2025_Redacted1.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DOOR NUMBER

(REFER TO DOOR SCHEDULE)

DOOR TAG

ARCHITECTURAL SYMBOLS

WINDOW TYPE LETTER

WINDOW TYPE TAG

SPECIALITY ITEM NUMBER

SPECIALITY ITEM TAG

PARTITION TYPE DESIGNATION

(REFER TO PARTITION SCHEDULE)

PARTITION TYPE TAG

PARTITION IN PLAN

ROOM

A1

A-301

ROOM TAG

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL TAG

ROOM NAME

ROOM NUMBER

A-401 INTERIOR ELEVATION

TAG

INTERIOR ELEVATION NUMBER

SHEET WHERE DRAWN

EXTERIOR ELEVATION

TAG

ELEVATION NUMBER

DIRECTION OF VIEW

SHEET WHERE DRAWN

A1

A-301

WALL / PARTIAL

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

A1

A-301

BUILDING SECTION

TAG

SECTION NUMBER

SHEET WHERE DRAWN

A1

A-301

BUILDING

NEW WORK

KEYNOTE TAG

KEYNOTE NUMBER

DEMO

KEYNOTE TAG

KEYNOTE NUMBER

A-901 PHOTOGRAPH TAG

PHOTOGRAPH NUMBER

SHEET WHERE SHOWN

A1

A-501

A1

SIM

A1

A1

A1

B

A1

A

SIGNAGE TYPE TAG

SIGNAGE TYPE LETTER

MATERIALS LEGEND

CONCRETE MASONRY UNIT

CAST-IN-PLACE CONCRETE (CIP) - WALLS, FLOORS,

ROOFS

STEEL

BATT/LOOSE FILL INSULATION

RIGID INSULATION

WOOD - ROUGH

WOOD BLOCKING

EFS - DIRECT APPLIED EXTERIOR FINISH SYSTEM

CMU - UNPAINTED & SEALED

SECTION ELEVATION

CMU - PAINTED

GLAZED BLOCK

GLAZING

SPANDREL GLAZING / STEEL PANEL

CONCRETE FOUNDATION

EARTH / NATIVE SOIL UNCOMPACTED

GRAVEL / COMPACTED BASE COURSE

ALUMINUM

BRICK

GYPSUM BOARD

PLYWOOD

SAND / MORTAR / PLASTER

ACOUSTICAL TILE CEILING

CERAMIC OR PORCELAIN TILE

FINISHED WOOD - PAINTED OR STAINED

COMPACTED FILL SUBGRADE - SAND, GRAVEL , EARTH

GENERAL SHEET NOTES

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :5

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

A-001

JF

Y

P

R O

JE

C

T J

-8

A R

C H

IT

E

C T

U R

A L

N O

TE

S

A N

D S

Y M

B O

LS

JG

17321900

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A -0

AAP ATTIC ACCESS PANEL - CEILING

AB ANCHOR BOLT

ACP ACOUSTICAL CEILING PANEL

ACS PNL ACCESS PANEL

ACT ACOUSTICAL CEILING TILE

ADJ ADJUST

AFF ABOVE FINISHED FLOOR

ALT ALTERNATE, ALTITUDE

ALUM ALUMINUM

ANOD ANODIZED

AP ACCESS PANEL - WALL

APPROX APPROXIMATE

ARCH ARCHITECT

ASPH ASPHALT

BD BOARD

BLDG BUILDING

BLW BELOW

BM BEAM

BOS BOTTOM OF SLAB / STEEL

BOT BOTTOM

BRG BEARING

BSMT BASEMENT

BTWN BETWEEN

C TO C CENTER TO CENTER

CAB CABINET

CEM CEMENT

CER CERAMIC

CI CAST IRON

CIP CAST IRON PIPE

CJ CONTROL / CONSTRUCTION JOINT

CL CENTER LINE

CLG CEILING

CLG REG CEILING REGISTER

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CND CONDUIT

CNDS CONDENSATE

CNSTR CONSTRUCTION

CNTR CNTR

CO CLEANOUT

COC COMBAT OPERATIONS CENTER

COL COLUMN

CONC CONCRETE

CONN CONNECT

CONT CONTINUE / CONTINUOUS

CORR CORRIDOR

CPT CARPET / COMMON PATH OF TRAVEL

CT CERAMIC TILE

CTR CENTER

D DEPTH / DEEP

DEFS DIRECT-APPLIED EXTERIOR FINISH

SYSTEM

DEG DEGREE

DEMO DEMOLITION

DET DETAIL

DIA DIAMETER

DIM DIMENSION

DR DRAIN

DS DOWNSPOUT

DW DISHWASHER

DWG DRAWING

E EAST

EA EACH

EIFS EXTERIOR INSULATION & FINISH

SYSTEM

EJ EXPANSION JOINT

ELEC ELECTRIC / ELECTRICAL

ELEV ELEVATION

EPDM ETHLENE PROPYLENE DIEN

MONOMER

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION / EXPOSED / EXPAND

EXT EXTERIOR

FD FLOOR DRAIN

FDTN FOUNDATION

FF FINISH FACE

FG FIGURE

FHC FIRE HOUSE CABINET

FIN FLR FINISHED FLOOR

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUB / FACE OF SLAB

FR FRAME / FIRE RATING / FIRE

RESISTANT

FT FOOT, FEET

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GFCI GOVERNMENT FURNISHED

CONTRACTOR INSTALLED

GL GLASS / GROUND LEVEL

GR GROSS

GSU GLAZED STRUCTURAL UNIT

GYP GYPSUM

H HIGH

H HEIGHT

HB HOSE BIB

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HVY HEAVY

ID INSIDE DIAMETER

INSUL INSULATION / INSULATED

INT INTERIOR

J-BOX JUNCTION BOX

JAN JANITOR CLOSET

LAV LAVATORY

LB POUND

LID LOW IMPACT DEVELOPMENT

LT LIGHT

MACH MACHINE

MATL MATERIAL

MAX MAXIMUM

MBH MOP AND BROOM HOLDER

MECH MECHANICAL

MFR MANUFACTURER

MI MIRROR

MIN MINIMUM / MINUTE

MISC MISCELLANEOUS

ML MATCH LINE

MO MASONRY OPENING / MOTOR

OPERATED

MTD MOUNTED

MTG MOUNTING / MEETING

MTL METAL

MWP MEMBRANE WATERPROOFING

N NORTH

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OA OUTSIDE AIR

OC ON CENTER

OD OUTSIDE DIAMETER / DIMENSION

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPT OPTIONAL

PCT PERCENT

PEJ PREMOLDED EXPANSION JOINT

PL PROPERTY LINE

PLAS PLASTER / PLASTIC

PLYWD PLYWOOD

PNL PANEL

PRELIM PRELIMINARY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT

QT QUARRY TILE

QTY QUANTITY

R RADUIS / RISER

RA RETURN AIR

RAD RETURN AIR DUCT

RAF RAISED ACCESS FLOORING

RB RESILIENT BASE

RD ROOF DRAIN / ROAD

REFL REFLECT

REFR REFRIGERATION

REINF REINFORCE

REQD REQUIRED

REV REVISION

RF RESILIENT FLOORING

RL ROOF LEADER

RM ROOM

RND ROUND

RO ROUGH OPENING

RS ROUGH SAWN

RT RIGHT

S SOUTH

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SIM SIMILAR

SOG SLAB-ON-GRADE

SPEC SPECIFICATION

SQ SQUARE

STD STANDARD

STOR STORAGE

STRL/STRUC

T

STRUCTURAL

SUSP SUSPENDED

T&B TOP AND BOTTOM

TEL TELEPHONE

THRES THRESHOLD

THRU THROUGH

TOS TOP OF SLAB / STEEL

TP TOILET PARTITION

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

V VOLT

VAR VARIATION

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VENT VENTILATION / VENTILATOR

VERT VERTICAL

VEST VESTIBULE

VS VENT STACK

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W WASTE / WATT / WEST / WIDE

W/ WITH

W/O WITHOUT

WC WATER CLOSET / WALL COVERING

WD WOOD

WH WATER HEATER

WP WATERPROOFING / WEATHERPROOF

WR WATER RESISTANT

WSCT WAINSCOT

WT WEIGHT

WWF WELDED WIRE FABRIC

XRMR TRANSFORMER

ARCHITECTURAL ABBREVIATIONS

1. ALL ITEMS INDICATED TO BE REMOVED MUST BE DISPOSED OF OFF SITE

UNLESS OTHERWISE NOTED.

2 ALL MATERIALS MUST BE NEW AND PROVIDED BY THE CONTRACTOR

UNLESS SPECIFICALLY NOTED AS EXISTING OR AS PROVIDED BY THE

GOVERNMENT.

3 ALL WOOD BLOCKING AND MISCELLANEOUS STEEL SHOWN IN DETAILS AND

SECTIONS MUST BE CONTINUOUS UNLESS SPECIFICALLY NOTED

OTHERWISE.

4 VERIFY ALL FIELD CONDITIONS AND DIMENSIONS PRIOR TO PROCEEDING

WITH THE WORK. DIMENSIONS FOR EXISTING WORK ARE INDICATED AS "±".

ALL DISCREPANCIES MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF

THE CONTRACTING OFFICER IN WRITING.

5 DEMOLITION OF PLUMBING, MECHANICAL AND ELECTRICAL ITEMS

INDICATED ON THE ARCHITECTURAL DRAWINGS IS NOT INTENDED TO

INCLUDE ALL NECESSARY DEMOLITION WORK FOR THESE ITEMS. REFER

TO PLUMBING, MECHANICAL AND ELECTRICAL DEMOLITION DRAWINGS FOR

ADDITIONAL INFORMATION.

6 DIMENSIONS INDICATED FOR NEW WORK ARE TO FACE OF STUD, FACE OF

MASONRY OR FACE OF EXISTING SURFACES UNLESS OTHERWISE NOTED.

7 STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER,

AND AT ONCE, REPORT TO THE ARCHITECT ANY ERRORS AND

INCONSISTENCIES OR OMISSIONS DISCOVERED. ANY CONSTRUCTION

ACTIVITY PERFORMED KNOWING IT INVOLVES A RECOGNIZED ERROR,

INCONSISTENCY OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT

SUCH NOTICE TO THE ARCHITECT, THE CONTRACTOR WILL ASSUME

RESPONSIBILITY FOR SUCH PERFORMANCE AND WILL BEAR THE AMOUNT

OF THE COST OF THE CONSTRUCTION.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

03/ /2026

AS103

A5AS104

A4

TRASH

ENCLOSURE

CHILLER

ENCLOSURE

TRANSFORMER

ENCLOSURE

AS102

A3

PEDESTRIAN GATE,

SEE CIVIL

PEDESTRIAN GATE,

SEE CIVIL

PEDESTRIAN GATE,

SEE CIVIL

J-875 BSTF

W A

T C

H T

O W

E R

R D

ICEBURG ST

PROJECT BOUNDARY, SEE CIVIL DRY SWALE, SEE CIVIL HIGH SECURITY CHAIN LINK

FENCE, SEE CIVIL

EXTERIOR

COC PAD

UTILITY TRENCH,

SEE CIVIL

LID DETENTION BASIN,

SEE CIVIL

SLIDING GATE,

SEE CIVIL

DRY SWALE, SEE CIVIL

OPTION ITEM #1

AS101

A2

AS101

D2

OPTION ITEM #2

AS105

A1

MONUMENT

SIGNAGE

AS105

A3

H-FRAME

SIGNAGE

AS107

A1

GENERATOR AND FUEL

TANK ENCLOSURE

AS110

A3

PAVILION

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :2

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS101

JF

Y

P

R O

JE

C

T J

-8

A R

C H

IT

E

C T

U R

A L

S

IT

E P

LA

N

A N

D O

P T

IO

N

IT

E

M S

JG

17321901

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

PLAN

NORTH

SCALE: 1" = 30'-0"

A1

ARCHITECTURAL SITE PLAN

SCALE: 1" = 30'-0" (A-201)

A2

OPTION ITEM #2

SCALE: 1" = 30'-0" (A-201)

D2

OPTION ITEM #1

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P

T.O. BLDG FOOTING

-4'-0"

CHILLER SOG

0"

8' -6

1'

-6

4' -0

'-0

BASE COURSE,

SEE CIVIL

CAPILLARY WATER

BARRIER, SEE STRL

CONC FOOTING,

SEE STRL

STRL POST, SEE STRL

STRL BEAM, SEE STRL

AS111

D1

AS111

D2

EF-1

CHILLER,

SEE MECH

ENCLOSURE

WALL, TYP.

MTL

LOUVER AS

SCHED, TYP

EF-5

LOUVERS AND

FRAMES, TYP.

CHILLER SOG

0"

2' -0

6'

-0

2' -0

LIGHT FIXTURE, SEE ELEC

'-0

EF-1

EF-5

LOUVERS AND

FRAMES, TYP.

ENCLOSURE

WALL, TYP.

CHILLER SOG

0"

A1

AS102

A1

AS102

2' -0

6'

-0

2' -0

'-0

FACE OF BUILDING

EF-1

EF-5

LIGHT FIXTURE, SEE ELEC

ENCLOSURE

WALL, TYP.

LOUVERS AND

FRAMES, TYP.

CHILLER SOG

0"

A1

AS102

A1

AS102

FACE OF BUILDING

2' -0

8'

-0 " 10

'-0

"EF-5

EF-1

BLDG WALL, TYP.

LOUVERS AND

FRAMES, TYP.

LIGHT FIXTURE, SEE ELEC

A

5 6 7

A1

AS102

A1

AS102

D1

AS102

D3

AS102

C1

AS102

LVR-110

LVR-110

LVR-110LVR-110

LVR-110

10'-0" 37'-8"

6' -0

'-1

8' -9

116B

3' -2

6'

-0

1' -1

0" 9'

-6

1' -1

0" 6'

-0

CHILLER,

SEE MECH

3' -2

6'

-0

3' -7

6'

-0

3' -7

6'

-0

2' -6

9'-1 1/2" 6'-0" 9'-5" 6'-0" 7'-1 1/2"

6'-0" 10'-3" 5'-2" 10'-3" 4'-0"

'-1

0"

LVR-110

2' -6

STL BEAM

ABOVE, SEE

STRL, TYP.

6" HIGH CONC

PAD, SEE

STRL, TYP.

NOTE: PROVIDE HEAVY-DUTY WOVEN WIRE MESH

CEILING PANELS COVERING THE ENTIRE INTERIOR

FOOTPRINT OF THE MECHANICAL CHILLER

ENCLOSURE. PANELS MUST BE REMOVABLE TO

PERMIT EQUIPMENT MAINTENANCE

HEAVY-DUTY

WOVEN WIRE MESH

CEILING PANEL

ABOVE, SEE STRL

LVR-110

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :2

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS102

JF

Y

P

R O

JE

C

T J

-8

C H

IL

LE

R E

N C

LO

S

U R

E P

LA

N

, E X

TE

R

IO

R

E

LE

V A

T

IO

N S

, A N

D S

E C

T

IO

N

JG

17321902

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

PLAN

NORTH

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (AS102)

A1

SECTION

SCALE: 1/4" = 1'-0" (AS102)

C1

EXTERIOR ELEVATION - SOUTH

SCALE: 1/4" = 1'-0" (A-103)

D1

EXTERIOR ELEVATION - EAST

SCALE: 1/4" = 1'-0" (A-102)

D3

EXTERIOR ELEVATION - WEST

SCALE: 1/4" = 1'-0" (AS101)

A3

CHILLER ENCLOSURE FLOOR PLAN

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

'-0

16'-0"

3' -2

3'-2"

3'-2"

2'-7" 2'-7"

C3

AS103

C3

AS103

A3

AS103

B3

AS103

TRANSFORMER,

SEE ELEC

6" HIGH

CONC PAD

TRANSFORMER

ENCLOSURE SOG

0"

EF-1

ENCLOSURE

WALL, TYP.

7' -6

TRANSFORMER

ENCLOSURE SOG

0"

C3

AS103

C3

AS103

EF-1

7' -6

ENCLOSURE

WALL, TYP.

TRANSFORMER

ENCLOSURE SOG

0"

7' -6

EF-1

ENCLOSURE

WALL, TYP.

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :2

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS103

JF

Y

P

R O

JE

C

T J

-8

TR

A

N S

F O

R M

E R

E N

C

LO

S U

R E

P

LA

N , E

X T

E R

IO

R

E

LE

V A

T

IO

N S

, A N

D S

E C

T

IO

N

JG

17321903

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

PLAN

NORTH

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (AS101)

A5

TRANSFORMER ENCLOSURE FLOOR PLAN

SCALE: 1/4" = 1'-0" (AS103)

A3

EXTERIOR ELEVATION - EAST (SOUTH AND WEST SIM)

SCALE: 1/4" = 1'-0" (AS103)

B3

EXTERIOR ELEVATION - NORTH

SCALE: 1/4" = 1'-0" (AS103)

C3

SECTION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

C4

AS104

C4

AS104

39'-4"

1'-4" 17'-4" 2'-0" 17'-4" 1'-4"

'-0

R 4" R 4" R 4" R 4"

1'-0"

1' -0

1'-0" 1'-0"

1' -0

1'-0"

B4

AS104

B4

AS104

TRASH BIN TRASH BIN RECYCLE BIN RECYCLE BIN

C1

AS104

B1

AS104

A2

AS104

4x12 TREATED WOOD BUMPER

W/ TYPE 316 SS BOLT (TYP) @

24" OC, BOTH BAYS

10" HIGH CONC CURB,

SEE STRL, BOTH BAYS

TRASH ENCLOSURE

SOG

0"

B4

AS104

B4

AS104

7' -6

4' -6

10" HIGH CONC CURB,

SEE STRL, BOTH BAYS

4x12 TREATED WOOD BUMPER

W/ TYPE 316 SS BOLT (TYP) @

24" OC, BOTH BAYS

AS111

A1

AS111

A3

ENCLOSURE

WALL, TYP.

EF-1

TRASH ENCLOSURE

SOG

0"

C4

AS104

C4

AS104

7' -6

4' -6

CONC PAVEMENT,

SEE CIVIL

10" HIGH

CONB CURB

4x12 TREATED WOOD

BUMPER W/ TYPE 316

SS BOLT (TYP) @ 24" OC

10" HIGH CONC CURB,

SEE STRL, BOTH BAYS

EF-1

ENCLOSURE

WALL, TYP.

TRASH ENCLOSURE

SOG

0"

B4

AS104

B4

AS104

4x12 TREATED WOOD BUMPER

W/ TYPE 316 SS BOLT (TYP) @

24" OC, BOTH BAYS

10" HIGH CONC CURB,

SEE STRL, BOTH BAYS

CONC WALL

BEYOND

7' -6

4' -6

39'-4"

1'-4"17'-4"2'-0"17'-4"1'-4"

EF-1

ENCLOSURE

WALL, TYP.

TRASH ENCLOSURE

SOG

0"

B4

AS104

B4

AS104

CONC WALL BEYOND

10" HIGH CONC

CURB BEYOND

7' -6

4x12 WOODEN

BUMPER BEYOND

4' -6

EF-1

ENCLOSURE

WALL, TYP.

TRASH ENCLOSURE

SOG

0"

C4

AS104

C4

AS104

10" HIGH CONC

CURB BEYOND

4x12 WOODEN

BUMPER BEYOND

CONC CURB

BEYOND

7' -6

4' -6

ENCLOSURE

WALL, TYP.

EF-1

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :2

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS104

JF

Y

P

R O

JE

C

T J

-8

TR

A

S H

E N

C

LO

S U

R E

P

LA

N , E

X T

E R

IO

R

E

LE

V A

T

IO

N S

, A N

D S

E C

T

IO

N S

JG

17321904

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

PLAN

NORTH

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (AS101)

A4

TRASH ENCLOSURE FLOOR PLAN

SCALE: 1/4" = 1'-0" (AS104)

C4

TRANS ENCLOSURE LONGITUDINAL SECTION

SCALE: 1/4" = 1'-0" (AS104)

B4

TRANS ENCLOSURE CROSS SECTION

SCALE: 1/4" = 1'-0" (AS104)

C1

EXTERIOR ELEVATION - NORTH

SCALE: 1/4" = 1'-0" (AS104)

B1

EXTERIOR ELEVATION - SOUTH

SCALE: 1/4" = 1'-0" (AS104)

A2

EXTERIOR ELEVATION - EAST (WEST SIM)

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

1'-0"

3' -0

1'

-8

1' -0

3'-0"

#6

, E

F

#6@12, EF

#6@12

#6@12

#4@12

5' -6

ALUM SIGN POST

SLOPE FROM CENTER

FINISH SURFACE

(WHERE OCCURS)

2'-0"

#4 HOOPS @ 4" O.C.

4,000 PSI CONC.

(6) #6 VERT. BARS

3' -0

E

M B

E D

ALUM POST ALUM POST

SIGNAGE PLAN

PLAN

SECTION

SECTION

3' -6

PROTECT ALUM

SURFACES IN CONTACT

WITH CONCRETE PER

SPECIFICATIONS

3" M

IN

C

O V

E R

3" MIN COVER

4"X4" FULLY GROUTED

NON-REMOVABLE ALUM

SUPPORT POST, EF-3

ALUM SIGN BOARD, EF-6

3' -6

3'

-0

3'-6"

AUTHORIZED EMBLEM,

VINYL SURFACE APPLIED OR

SURFACE SCREENPRINT,

VERIFY WITH GOVERNMENT

VINYL HELVETICA MEDIUM

1/8" WIDE SURFACE APPLIED

OR SURFACE SCREENPRINT

LETTERS, VERIFY WITH

GOVERNMENT ON EXACT

NAME, COLOR: EF-7 Battle Staff

Training Facility

3"

4"

CONC FOOTING,

SEE DETAIL

B4/AS105

Bldg No.

VERIFY WITH

GOVERNMENT ON

BUILDING NUMBER,

COLOR: EF-7

Battle Staff Training Facility

10"X10" TRAVERTINE

ON CONC, RUNNING

BOND PATTERN

ORG. EMBLEM, BRONZE METAL PLAQUE

W/ UV FADE RESISTENT, BAKED ON

COLORS WITH POLYURETHANE FINISH,

VERIFY WITH GOVERNMENT

EFS ON

CONC, EF-9

EFS ON

CONC, EF-8

DARK BRONZE HELVETICA

MEDIUM 1/2" DEEP LETTERS,

SURFACE MOUNTED TO CONC,

VERIFY WITH GOVERNMENT

ON EXACT NAME

4"

8"

1' -8

3'

-0

3"

4' -1

1"

C3

AS105

1'-0" 1'-5"

7" 1'

-6

10"

4"

1/

2"

CONC FOOTING10"

5'-10" 3"

5" 1'

-1

1' -0

E Q

E Q

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :2

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS105

JF

Y

P

R O

JE

C

T J

-8

S

IT

E S

IG

N

A G

E

JG

17321905

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

1" = 1' - 0" 0 6" 1' 3'2'

GRAPHIC SCALE(S)

SCALE: 1" = 1'-0" (AS105)

C3

EXTERIOR MONUMENT SIGN - SECTION

SCALE: 1" = 1'-0"

C4

EXTERIOR SIGN - FOOTING DETAILS

SCALE: 1" = 1'-0" (AS101)

A3

EXTERIOR SIGN - ELEVATION

SCALE: 1" = 1'-0" (AS101)

A1

EXTERIOR MONUMENT SIGN - ELEVATION

SCALE: 1" = 1'-0"

C1

EXTERIOR MONUMENT SIGN - PLAN

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

EXTERIOR WALL MOUNTED

NO SMOKING SIGN

(LOCATED AT PRIMARY PUBLIC ENTRY POINT, STAFF ENTRY AND OUTSIDE

OF STAIR, SEE EXTERIOR ELEVATIONS)

NO SMOKING

WITHIN 50 FEET OF

ALL BUILDING

ENTRIES

DARK BRONZE BAKED

ENAMEL ALUM PANEL

TEXT: 1/2" HEIGHT,

COLOR 408 SOFT WHITE

NO SMOKING GRAPHIC,

COLOR REFLECTIVE

RED AND BLACK VINYL

GRAPHIC FIELD

PAINTED WHITE

T O

F

LO

O R

8"

1' -0

HOURS OF OPERATION

MONDAY - FRIDAY

8:00AM - 5:00 PM

EXTERIOR VINYL LETTERS

HOURS OF OPERATION

(LOCATED AT PRIMARY PUBLIC ENTRY POINT, SEE

EXTERIOR ELEVATIONS)

5/8" TEXT HEIGHT, FONT:

HELVETICA NEUE 65 MEDIUM,

COLOR 408 SOFT WHITE

T O

F

LO

O R

1'-6"

Battle Staff

EXTERIOR WALL MOUNTED

PRIMARY ENTRANCE

1-1/4"" HIGH TEXT APPLIED

DIE CUT VINYL, HELVETICA

NEUE 75 BOLD, COLOR:

SW7101 FUTON, VERIFY

NAME WITH GOVERNMENT

3" HIGH TEXT APPLIED DIE

CUT VINYL, HELVETICA NEUE

85 HEAVY, COLOR: SW7101

FUTON, VERIFY BLDG

NUMBER WITH GOVERNMENT

REMOVABLE END CAPS,

COLOR TO MATCH SIGNBOARD

1 1/8" 1 1/8"

1/

8"

12341 1/

4"

1/ 4"

3/ 4"

Training Facility

ALUMINIUM BACKGROUND

COLOR: TO MATCH NORTH

CREEK BROWN 1001

1' -6

T O

F

LO

O R

BXXX

2'-0"

1' -0

2"

ALUMINUM SIGN BOARD

MOUNTED TO CONC WALL

W/ SSTL FASTENERS.

COLOR: MATCH NORTH

CREEK BROWN 1001

HELVETICA MEDIUM 6"

NUMBER HEIGHT

VINYL SURFACE APPLIED.

COLOR: WHITE

VERIFY WITH GOVERNMENT

ON BUILDING NUMBER

LOCATED ON 4 EXTERIOR WALLS, SEE

EXTERIOR ELEVATIONS

The development of this facility was funded by the Government of Japan based on the Agreement between Japan and the United States of America.

The relocation of U.S. Marine Corps personnel from Okinawa to locations outside of Japan, including Guam, contributes to sustaining the forward presence of U.S. forces and facilitates the development of Guam as a strategic hub, while also mitigating the impact on Okinawa.

A historic milestone toward a more roburst alliance is commemorated here.

Dedicated to Japanese and American Goodwill and Friendship

日本国民と米国民の親善と友好のために

この施設は、日本とアメリカ合衆国との合意に基づき、日本政府からの資金拠出により整備されたもの である。沖縄からグアムを含む日本国外の場所への米海兵隊の要員の移転が、沖縄への影響を軽減し

つつ、米軍の前方プレゼンスを維持することに寄与し、グアムの戦略的な拠点としての発展を促進する。 より力強い同盟へ向けた歴史的な一歩をここに記念する。

FLAG OF JAPAN, SILK-SCREEN PRINTING

FLAG OF THE UNITED STATES OF

AMERICA, SILK SCREEN PRINTING

Naval Facilities

Engineering Systems Command

米海軍施設技術部隊

FONT: MYRIAD PRO BOLD CONDENSED

SIZE: 26PT

FONT: MYRIAD PRO BOLD CONDENSED

SIZE: 20PT

FONT: MYRIAD PRO BOLD CONDENSED

SIZE: 24PT

FONT: KOZUKA GOTHIC Pr6N

SIZE: 17.15PT

FONT: KOZUKA GOTHIC Pr6N

SIZE: 16PT

BENEFICIAL OCCUPANCY DATE (BOD)

YEAR OF EACH FACILITY TO BE INDICATED,

FONT: MYRIAD PRO BOLD CONDENSED

SIZE: 24PT

COLOR CODE: #FEFEFE

COLOR CODE: #CB7872

COLOR CODE: #CB7872

COLOR CODE: #CB7872

5.0 7.5 5.0 5.0

.0

.5

420mm

.3 m m

126.0

3.5

126.0

3.5

126.0

S E

E E

X T

E

LE

V A

T

IO

N S

SIGN BOARD: 3mm THK STAINLESS WITH ENAMEL COATING BACK BOARD: 3mm THK STAINLESS

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :2

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS106

JF

Y

P

R O

JE

C

T J

-8

B U

IL

D

IN

G

S

IG

N A

G E

JG

17321906

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

6" = 1' - 0" 0 4" 6"2"1"

3" = 1' - 0" 0 3" 6" 1'

GRAPHIC SCALE(S)

SCALE: 3" = 1'-0"

A2

NO SMOKING SIGN

SCALE: 3" = 1'-0"

A5

HOURS OF OPERATION SIGN

SCALE: 3" = 1'-0"

B2

ENTRY SIGN

SCALE: 3" = 1'-0"

A3

BUILDING NUMBER SIGN

SCALE: 6" = 1'-0"

B4

FACILITY RECOGNITION PLAQUE

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

6" HIGH

CONC PAD

CONC

PEDESTAL,

SEE STRL

ROOF OVERHANG ABOVE

FUEL TANK,

SEE MECH

GENERATOR,

SEE ELEC

FUEL TANK

SADDLE

A1

AS109

A1

AS109

A4

AS108

C4

AS109

C4

AS109

A4

AS109

A4

AS109

C4

AS108

A1

AS108

C1

AS108

GENERATOR

ENCLOSURE

FUEL TANK

ENCLOSURE

AIRWELL

AIRWELL

AIRWELL

LVR-214

LVR-212

LVR-213

5'-0" 8'-6" 5'-6" 3'-0"

6' -7

1'

-6

'-7

1'

-6

6' -7

5'-9" 7'-8" 5'-9"

5' -1

0"

'-5

5' -1

0"

'-9

5'

-1 0"

3' -0

3'-0" 14'-6" 3'-0" 3'-0"

A1

AS109

A1

AS109

A4

AS109

A4

AS109

C4

AS108

A1

AS108

C1

AS108

3'-0" 3'-0"

5' -1

0" 3'

-0

3' -0

5'

-1 0"

3'-0" 3'-0"

5' -1

0" 3'

-6

5' -1

0"

R

ID

G E

FLUID APPLIED

ROOFING

SYSTEM ON

CONC ROOF

AIR WELL BELOW

AIR WELL BELOW

AIR WELL BELOW

GENERATOR

ENCLOSURE BELOW

SLOPESLOPE

S L

O P

E S

L O

P E

3'-6"3'-6"

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:5

:2

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS107

JF

Y

P

R O

JE

C

T J

-8

G E

N E

R A

TO

R

F

U E

L

TA

N K

E N

C

LO

S U

R E

P

LA

N A

N D

R O

O F

P

LA

N , O

P T

IO

N

IT

E

M

JG

17321907

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

PLAN

NORTH

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (AS101)

A1

GENERATOR & FUEL TANK ENCLOSURE PLAN

SCALE: 1/4" = 1'-0" (AS103)

A4

GENERATOR & FUEL TANK ENCLOSURE ROOF PLAN

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

TRASH ENCLOSURE

SOG

0"

GENERATOR AND FUEL

TANK ENCLOSURE SOG

0"

T.O. GENERATOR

ENCLOSURE WALL

20'-0"

T.O. AIRWELL WALL

10'-5"

METAL ANGLE BRACKET,

TYP. SECURE TO POST

AND WALL

WIRE MESH

PARTITION

22'-0 1/2"

1/2" 12"

1/2" 12"

1/2" 12"

1/2" 12"

EF-2

EF-2

ENCLOSURE

WALL, TYP.

ENCLOSURE

WALL, TYP.

RF-1

EF-2

ROOF, TYP.

ENCLOSURE

WALL, TYP.

GENERATOR AND FUEL

TANK ENCLOSURE SOG

0"

T.O. GENERATOR

ENCLOSURE WALL

20'-0"

T.O. AIRWELL WALL

10'-5"

WIRE MESH

PARTITION

27'-11"

CLCLCLEQ EQ EQ EQ

1/2" 12"

1/2" 12"

1/2" 12"

1/2" 12"

EF-2

EF-2

EF-4

RF-1

EYEBROW, TYP.

ROOF, TYP.

ENCLOSURE

WALL, TYP.

ENCLOSURE

WALL, TYP.

GENERATOR AND FUEL

TANK ENCLOSURE SOG

0"

T.O. GENERATOR

ENCLOSURE WALL

20'-0"

T.O. AIRWELL WALL

10'-5"

EF-2

1/2" 12"

1/2" 12"

EF-4

RF-1

EYEBROW, TYP.

ROOF, TYP.

ENCLOSURE

WALL, TYP.

EF-2

ENCLOSURE

WALL, TYP.

GENERATOR AND FUEL

TANK ENCLOSURE SOG

0"

T.O. GENERATOR

ENCLOSURE WALL

20'-0"

T.O. AIRWELL WALL

10'-5"

METAL ANGLE BRACKET, TYP

SECURE TO POST AND WALL

WIRE MESH

PARTITION

FACILITY RECOGNITION

PLAQUE, SEE B4/AS106

4' -1

0"

1'-4"

EF-2

EF-2

ENCLOSURE

WALL, TYP.

ENCLOSURE

WALL, TYP.

8' -2

1/2" 12"

1/2" 12"

1/2" 12"

EF-2

ENCLOSURE

WALL, TYP.

1/2" 12"

RF-1

ROOF, TYP.

22'-0 1/2"

EF-4

EYEBROW, TYP.

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :3

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS108

JF

Y

P

R O

JE

C

T J

-8

G E

N E

R A

TO

R

F

U E

L

TA

N K

E N

C

LO

S U

R E

E

LE

V A

TI

O

N S

, O P

TI

O

N

IT

E M

JG

17321908

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (AS107)

A1

GENERATOR & FUEL TANK ENCLOSURE -

SOUTH ELEVATION

SCALE: 1/4" = 1'-0" (AS107)

A4

GENERATOR & FUEL TANK ENCLOSURE - EAST ELEVATION

SCALE: 1/4" = 1'-0" (AS107)

C4

GENERATOR & FUEL TANK ENCLOSURE - WEST ELEVATION

SCALE: 1/4" = 1'-0" (AS107)

C1

GENERATOR & FUEL TANK ENCLOSURE -

NORTH ELEVATION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

GENERATOR AND FUEL

TANK ENCLOSURE SOG

0"

T.O. GENERATOR

ENCLOSURE WALL

20'-0"

T.O. GENERATOR

ENCLOSURE FOOTING

-4'-0"

T.O. AIRWELL WALL

10'-5"

6" HIGH CONC PAD

CONC PEDESTAL,

SEE STRL

FUEL TANK,

SEE MECH

EF-1, UNDERSIDE

OF STRUCTURE, TYP

CONC FOOTING

BEYOND, SEE STRL

STAINLESS STEEL

WIRE MESH

SCREEN, TYP

EF-2

AIRWELL

AIRWELL

GENERATOR

ENCLOSURE

FUEL TANK

ENCLOSURE

TYP

2'-4"

GENERATOR,

SEE ELEC

1/2" 12"

1/2" 12"

1/2" 12"

1/2" 12"

T Y

P

2' -6

ENCLOSURE

WALL, TYP.

RF-1

ROOF, TYP.

GENERATOR AND FUEL

TANK ENCLOSURE SOG

0"

T.O. GENERATOR

ENCLOSURE WALL

20'-0"

T.O. GENERATOR

ENCLOSURE FOOTING

-4'-0"

T.O. AIRWELL WALL

10'-5"

FUEL TANK,

SEE MECH

CONC PEDESTAL,

SEE STRL

AS111

D3

AS111

A5

AS109

C1

EF-2

RF-1

1/2" 12"

1/2" 12"

1/2" 12"

1/2" 12"

ENCLOSURE

WALL, TYP.

ROOF, TYP.

EF-2

ENCLOSURE

WALL, TYP.

EF-4

EYEBROW, TYP.

GENERATOR AND FUEL

TANK ENCLOSURE SOG

0"

T.O. GENERATOR

ENCLOSURE WALL

20'-0"

T.O. GENERATOR

ENCLOSURE FOOTING

-4'-0"

T.O. AIRWELL WALL

10'-5"

AS111

D3

STAINLESS STEEL WIRE

MESH SCREEN, TYP

6" HIGH CONC PAD

GENERATOR,

SEE ELEC

6"

7' -8

TYP

2'-4"

AIRWELL

EF-2

RF-1

EF-1, UNDERSIDE

OF STRUCTURE, TYP

ROOF, TYP.

ENCLOSURE

WALL, TYP.

EF-4

EYEBROW, TYP.

1/2" 12"

1/2" 12"

1/2" 12"

1/2" 12"

1' -0

1'-6"

POURED JOINT

SEALANT, SEE CIVIL

CONC PAVEMENT,

SEE CIVIL

CONC PEDESTAL,

SEE STRL

COMPACTED

BASE COURSE

FUEL TANK SADDLE

CONC FOOTING,

SEE STRL

6" 4"

1' -0

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :3

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS109

JF

Y

P

R O

JE

C

T J

-8

G E

N E

R A

TO

R

F

U E

L

TA

N K

E N

C

LO

S U

R E

S E

C T

IO

N

S , O

P T

IO

N

IT

E

M

JG

17321909

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (AS107)

A1

GENERATOR & FUEL TANK SECTION

SCALE: 1/4" = 1'-0" (AS107)

C4

GENERATOR & FUEL TANK SECTION

SCALE: 1/4" = 1'-0" (AS107)

A4

GENERATOR & FUEL TANK SECTION

SCALE: 1" = 1'-0" (AS109)

C1

CONC PEDESTAL DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

PAVILION SOG

0"

T.O. PAVILION ROOF

10'-6"

T.O. PAVILION FOOTING

-4'-0"

OPEN TO BEYONDOPEN TO BEYONDOPEN TO BEYOND

GRAVEL STRIP

6" CONC SLAB

SUBBASE COURSE

SUBGRADE

LIGHT FIXTURES, SEE ELEC

AS111

D3

EF-2

RF-1

1/2" 12"

1/2"

12"ROOF, TYP.

COLUMN, TYP.

PAVILION SOG

0"

T.O. PAVILION ROOF

10'-6"

OPEN TO BEYONDOPEN TO BEYONDOPEN TO BEYOND

ROOF, TYP.

COLUMN, TYP.

RF-1

1/2" 12"

1/2" 12"

FACILITY RECOGNITION

PLAQUE, SEE B4/AS106

EQ

4' -1

0"

EQ

EF-2

PAVILION SOG

0"

T.O. PAVILION ROOF

10'-6"

OPEN TO BEYOND

LIGHTING FITXURES,

SEE ELEC

ROOF, TYP.

COLUMN, TYP.

RF-1

1/2" 12"

1/2" 12"

B1

AS110

B1

AS110

D1

AS110

D1

AS110

A1

AS110

Sim

D3

AS110

SIM

D3

AS110

A1

AS110

CONC

PAVEMENT,

SEE CIVIL

ROOF

OVERHANG

ABOVE

CONC

BEAM

ABOVE

PAVILION SOG

0"

T.O. PAVILION ROOF

10'-6"

T.O. PAVILION FOOTING

-4'-0"

OPEN TO BEYOND

6" CONC SLAB

SUBBASE COURSE

SUBGRADE

CONC PAVING,

SEE CIVIL

LIGHTING FITXURES,

SEE ELEC

AS111

D3

RF-1

ROOF, TYP.

COLUMN, TYP.

1/2" 12"

1/2" 12"

B1

AS110

B1

AS110

D1

AS110

D1

AS110

D3

AS110

A1

AS110

A1

AS110

Sim

D3

AS110

SIM

CONC SLAB

BELOW

CONC

COLUMN

BELOW, TYP

FLUID APPLIED

ROOFING ON CONC

FORMED ROOF

R

ID

G E

S

LO

P E

SLOPE SLOPE

S

LO

P E

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :3

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS110

JF

Y

P

R O

JE

C

T J

-8

P A

V

IL

IO

N

P

LA

N S

, E

LE

V A

T

IO

N S

S

E C

TI

O

N S

, O P

T

IO

N

IT

E M

JG

17321910

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

PLAN

NORTH

1/4" = 1' - 0" 0 5' 10' 15'1'

GRAPHIC SCALE(S)

SCALE: 1/4" = 1'-0" (AS110)

D1

PAVILION SECTION

SCALE: 1/4" = 1'-0" (AS110)

D3

EAST ELEVATION (WEST SIM)

SCALE: 1/4" = 1'-0" (AS110)

A1

NORTH ELEVATION (SOUTH SIM)

SCALE: 1/4" = 1'-0" (AS101)

A3

PAVILION PLAN

SCALE: 1/4" = 1'-0" (AS110)

B1

PAVILION SECTION

SCALE: 1/4" = 1'-0" (AS104)

A4

PAVILION ROOF PLAN

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

CONNECTION PLATE,

SEE STRL

STL BEAM,

SEE STRL

STL POST, SEE

STRL

HEAVY DUTY WOVEN

WIRE MESH, SEE STRL

EFS ON CONC

8"

4x12 WOOD BUMPER

AT TRASH ENCLOSURE

COMPACTED

BASE COURSE

CONC FOOTING

SEE STRL

CONC PAD,

SEE STRL

CONC SLAB,

SEE STRL

SLOPE FINISH

GRADE

7' -3

1'

-6

CONC CURB AT

TRASH ENCLOSURE

8" 3'

-6

10" CONC WALL,

SEE STRL

1'-0"

1' -6

10" CONC WALL,

SEE STRL

COMPACTED

BASE COURSE

CONC FOOTING

SEE STRL

CONC SLAB,

SEE STRL

7' -3

CONC CURB AT

TRASH ENCLOSURE

8"

4x12 WOOD BUMPER

AT TRASH ENCLOSURE

3' -6

8"

1'-0" 1'-0"

COMPACTED

BASE COURSE

CONC PAVEMENT,

SEE CIVIL

CONC PAVEMENT,

SEE CIVIL

2" 7'

-1 0"

2"

8' -2

E Q

E Q

2" X 7" X 1/4" BASE PLATE WELDED TO POST AND

BOLTED TO CONC PAVEMENT WITH MIN. FOUR (4)

3/8" ANCHORS

2" X 1" - 10 GAUGE

WIRE MESH

1 1/4" X 1 1/4" X 1/8" METAL

ANGLE BAR

1 1/4" X 1 1/4" X 1/8" ANGLE

BAR

1 1/4" X 1 1/4" X 1/8" METAL

ANGLE BAR

COMPACTED BASE

COURSE

POURED JOINT

SEALANT, SEE CIVIL

DOOR

M

IN

.1

DOOR

WOVEN WIRE MESH

JAMB (HEAD SIM)

SILL DETAIL

TOP OF CURB

STEEL FRAME

"L" ANGLE STEEL PLATE

STEEL PLATE;

PUSH SIDE ONLY

SECURE PLATE

TO MESH

3" 1"

1"

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :3

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

AS111

JF

Y

P

R O

JE

C

T J

-8

S

IT

E D

E

TA

IL

S

JG

17321911

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A S

1" = 1' - 0" 0 6" 1' 3'2'

3" = 1' - 0" 0 3" 6" 1'

GRAPHIC SCALE(S)

SCALE: 3" = 1'-0" (AS102)

D1

WIRE MESH @ CONC WALL

SCALE: 3" = 1'-0" (AS102)

D2

WIRE MESH @ POST

SCALE: 1" = 1'-0" (AS104)

A1

CONC WALL SECTION

SCALE: 1" = 1'-0" (AS104)

A3

CONC WALL SECTION

SCALE: 1" = 1'-0" (AS109)

A5

CURB/FENCE SECTION

SCALE: 1" = 1'-0"

D5

DOOR @ MESH WALL

SCALE: 3" = 1'-0" (AS109)

D3

DRIP EDGE DETAIL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

UP

UP

UP

C3

A-201

A1

A-202

A1

A-201

C1

A-202

G

A

B

C

E

D

F

1 2 3 4 5 6 7 8 9

223'-10"

27'-11" 28'-0" 28'-0" 28'-0" 28'-0" 28'-0" 28'-0" 27'-11"

'-1

1"

'-0

'-0

'-0

'-0

'-1 1"

7'

-1 0"

TA - G4 LOGISTICS

TA - G7 COMM

STRAT

TA - G3 FOPS

105B

TA - G3 FOPS

105A

TA - G2

COLLECTIONS

AND ANALYSIS

108A

TA - HQ CAMP

COMMANDANT

TA - G3 FIRES

TA - G3 STRIKE

CELL

110A

TA - G3 STRIKE

CELL

110B

INTERIOR COC

TRAINING PAD

TA - G2

COLLECTIONS

AND ANALYSIS

108B

GTR 1T (TRAINING

TELECOMM RM)

GTR 1

SVTC CONF RM /

SIPR CAFE

MECH RM

ELEC RM

TA - MEDICAL

CELL

TA - COC WATCH

FLOOR

TA - G5 PLANS

TA - COMMAND

DECK

TA - G1

OPERATIONS

C4

A-301

C4

A-301

A1

A-301

A1

A-301

LOBBY 1

L1

ENTRY VESTIBULE

CHILLER

ENCLOSURE

119A

A-102

A1

A-103

A1

CTR 1

ELEV MACHINE RM

ELEV 1

E1

NURSING RM

BREAK RM

ENTRY CONTROL

POINT

102A

CORRIDOR 1C

C1C

VESTIBULE 1A

V1A

VESTIBULE 1C

V1C

VESTIBULE 1D

V1D

CORRIDOR 1A

C1A

ELEC CLOSET

CORRIDOR 1B

C1B

WOMEN

MEN

JAN

CORRIDOR 1E

C1E

OFFICE

128B

OFFICE

128A

OFFICE

127B

OFFICE

127A

OFFICE

126B

OFFICE

126A

VESTIBULE 1E

V1E

TELCOM CLOSET

126C

AV CLOSET

126D

STAIR 1C

S1C

STAIR 1B

S1B

STAIR 1A

S1A

C1

A-301

C1

A-301

OFFICE

125A

TRAINING

MATERIAL

STORAGE

EMERGENCY

GENERATOR

VESTIBULE 1B

V1B

1. REFER TO SHEET A-502 FOR PARTITION TYPES.

2. REFET TO SHEET A-750 FOR DOWNSPOUT DETAILS.

3. REFER TO SHEET A-730 FOR CORNER GUARD, FIRE EXTINGUISHER

CABINETS, RAISED ACCESS FLOORING, AND FLOOR DRAIN DETAILS.

RAISED ACCESS FLOORING

SECURED AREA BOUNDARY

SYMBOL DESCRIPTION

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :5

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

A-101

JF

Y

P

R O

JE

C

T J

-8

O V

E R

A

LL

F

IR

S T

F

LO

O R

P

LA

N

JG

17321912

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A -1

M A

T C

H

LI

N E

A B

SCALE: 1/16" = 1'-0"

A1

OVERALL FIRST FLOOR PLAN

PLAN

NORTH

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

OVERALL FLOOR PLAN LEGEND

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

1. REFER TO SHEET A-502 FOR PARTITION TYPES.

2. REFET TO SHEET A-750 FOR DOWNSPOUT DETAILS.

3. REFER TO SHEET A-730 FOR CORNER GUARD, FIRE EXTINGUISHER

CABINETS, RAISED ACCESS FLOORING, AND FLOOR DRAIN DETAILS.

PARTITION OR FURRED WALL

GRIDLINE

CONC WALL

CORNER GUARD

X

RECESSED ENTRY FLOOR MAT

SYMBOL DESCRIPTION

ROOMNAME

ROOM NAME AND NUMBER

101 DOOR NUMBER SYMBOL

A1

A-101

SECTION/ELEVATION

P1

A-101

A1 SIM

PARTITION TYPE

WINDOW SYMBOL

DOWNSPOUTDS

FLOOR DRAIN, SEE PLUMBINGFD

CG

A

FIRE EXTINGUISHER CABINETFEC

KNOX BOXKB

DETAIL REFERENCE

OPERABLE PARTITION TAG101

G

A

B

C

E

D

F

1 2 3 4 5 6

'-1

1"

'-0

'-0

'-0

'-0

'-1 1"

27'-11" 28'-0" 28'-0" 28'-0" 28'-0"

TA - G4 LOGISTICS

TA - G7 COMM

STRAT

TA - HQ CAMP

COMMANDANT

ENTRY CONTROL

POINT

102A

ENTRY VESTIBULE

LOBBY 1

L1

BREAK RM

NURSING RM

ELEC CLOSET

TA - G3 FIRES

TA - G3 STRIKE

CELL

110A

TA - G3 STRIKE

CELL

110B

CORRIDOR 1C

C1C

TA - G2

COLLECTIONS

AND ANALYSIS

108A

TA - G2

COLLECTIONS

AND ANALYSIS

108B

INTERIOR COC

TRAINING PAD

TA - G3 FOPS

105B

TA - G3 FOPS

105A

SVTC CONF RM /

SIPR CAFE

GTR 1

GTR 1T (TRAINING

TELECOMM RM)

MECH RM

CTR 1

ELEV MACHINE RM

ELEV 1

E1

VESTIBULE 1D

V1D

VESTIBULE 1A

V1A

101B 101A

105A105B

108A

108B

107A

107B

109A109B

111A

111B

110B

110A

116A

116B

109E

7' -0

2' -6

5' -0

6'

-0

3'-6" 6'-0"

3'-6"

6'-0" 3'-6"

'-5

5'

-0

'-5

5' -0

6'-0"

7' -0

8'-0 1/2" 12'-0"

5'-0"

3' -6

5'-0"

7' -0

3'

-6

5'-2" 5'-0"

3'-6"

5' -0

7'-0"

9' -4

STAIR 1B

S1B

P6ASM

P6AM

P6AM

F6

P6AM

P6A

4' -6

3'-6"

5' -0

3'-6"

P6AM

P6ASM

P6ASM

P6ASM

P6ASM

P6ASM

P6ASM

C3AS

F3A

F6

F6

P6A

P6A

P6A

P6A

P6A

1P6AM

P6A

1P6AM

P6A

P6AM

P6ASM

P6S

P6S

P6AM

P6AM

P6AM

P6AM

P6AM

P6A

P6A

P6A P6A

P6A

P6A P6A

P6A

P6A

P6A

P6A

P6A

P6A

P6A

P6A

P6A

P6AP6A P6A

P6A

1P6AM

P6A

F3A

1P6AM

F6

F6

F6

F6

P6A

P6ASM

F3A

P6A

P6A

P6A

P6S

C3AS

CORRIDOR 1B

C1B

P6AM

B2

A

A

A

F3A

F3A

F3A

F3AF3A F3A F3A F3A

F3A

109C

109D

E3 101E 101F

101D

E1.1

E2

P6A

5' -0

TRENCH DRAIN,

SEE CIVIL, TYP.

2' -0

B3

A-413

A3

SEE SCHEDULE

S E

E S

C H

E D

U

LE

SEE SCHEDULE

CG

CG

CG

CG

CGCG CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

CGCGCGCG CG

CG CG

CG

CG

CG

CG

CG

A-415

A3

P6A

6"

6"

DS DS

DS DS

DS

DS

DS DS DS

CORRIDOR 1A

C1A

CORRIDOR 1D

C1D

INTERIOR

UTILITY TRENCH

A4

A-311

A-504

D1

A-504

D2

A-504

D3

A-504

D4

A-504

D5

A-504

C1

A-504

C2

A-504

C3

A-504

C4

A-504

C5

A-504

B1

A-504

B2

A-504

B3

A-504

B4

A-504

B5

A-504

A1

WM

101C

4' -0

1P6

1P6

E1.2 E1

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :5

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

A-102

JF

Y

P

R O

JE

C

T J

-8

E N

LA

R

G E

D F

LO

O

R P

LA

N

1A

JG

17321913

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A -1

M A

T C

H

LI

N E

A B

PLAN

NORTH

1/8" = 1' - 0" 0 5' 10' 15' 30'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

FLOOR PLAN LEGEND

SCALE: 1/8" = 1'-0" (A-101)

A1

ENLARGED FLOOR PLAN - 1A

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

3. REFER TO SHEET A-730 FOR CORNER GUARD, FIRE EXTINGUISHER

CABINETS, RAISED ACCESS FLOORING, AND FLOOR DRAIN DETAILS.

G

A

B

C

E

D

F

5 6 7 8 9

'-1

1"

'-0

'-0

'-0

'-0

'-1 1"

TA - COC WATCH

FLOOR

VESTIBULE 1E

V1E

OFFICE

126A

OFFICE

126B

OFFICE

127B

OFFICE

127A

OFFICE

128A

OFFICE

128B

TA - G1

OPERATIONS

TA - COMMAND

DECK

TA - G5 PLANS

ENTRY VESTIBULE

LOBBY 1

L1

ELEV 1

E1

STAIR 1A

S1A

ELEV MACHINE RM

CTR 1

MECH RM

ELEC RM

MEN

JAN

WOMEN

OFFICE

125A

TA - MEDICAL

CELL

TELCOM CLOSET

126C

AV CLOSET

126D

STAIR 1C

S1C

101A101B

116A

116B

117B

119 120 120A

124 125

125A

126 126C

126D

125B 125CCORRIDOR 1E

C1E

126B

126A

126E

127A127B

128A128B

126F

7' -6

2'-0"

6'-0" 16'-8"

'-6

'-6

'-0

7' -6

6'

-0

'-4

7'-0"

9' -4

P6A P6A

P6A

P6A

P6A

P6A

P6AP6AP6A

P6A

P6A

P6A

P6A

P6A P6A

P6A

P6A

P6A

P6A

P6AP6AP6A

P6A

P6A

P6AS

P6AS

F6

F6

F6

F6

P6A

P6A

F3AF3A

P6A

P6A

F6

F6 F6

F3A

F3A

P6A

C3AS

P6S

C3AS

F3A

F3A

1P6A

P6A

B1

B1 101E 101F

101D

28'-0" 28'-0" 28'-0" 27'-11"

A-411

A1 2'

-0

B3

A-413

A3

CG

CG

CG

A-414

A3

C L

'-5

A-416

A3

DS

DS

DS

DS

DSDS

DS

TRENCH DRAIN,

SEE CIVIL, TYP.

FEC

FEC

LVR-102

LVR-106

FEC

P6A

A4

A-311

A-504

A2

2'-0" 11'-0"2'-0"

11'-6" 12'-4" 4'-0"

LVR-108

LVR-107

3'-0"

5' -0

5'-0" 7'-8"

11'-6" 11'-8"

TELCOM CLOSET

128C

P6

128C

P6S

P6AS

A-103

A4

TRAINING

MATERIAL

STORAGE

EMERGENCY

GENERATOR

OPTION ITEM #2

6' -3

4'

-4

6' -3

1'-6"

F3A

PARTITION OR FURRED WALL

GRIDLINE

CONC WALL

CORNER GUARD

X

RECESSED ENTRY FLOOR MAT

SYMBOL DESCRIPTION

ROOMNAME

ROOM NAME AND NUMBER

101 DOOR NUMBER SYMBOL

A1

A-101

SECTION/ELEVATION

P1

A-101

A1 SIM

PARTITION TYPE

WINDOW SYMBOL

DOWNSPOUTDS

FLOOR DRAIN, SEE PLUMBINGFD

CG

A

FIRE EXTINGUISHER CABINETFEC

KNOX BOXKB

DETAIL REFERENCE

OPERABLE PARTITION TAG101

A

B

C

8 9

TRAINING

MATERIAL

STORAGE

'-1

1"

'-0

27'-11"

TA - MEDICAL

CELL

OFFICE

125A

125A

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :5

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

A-103

JF

Y

P

R O

JE

C

T J

-8

E N

LA

R

G E

D F

LO

O

R P

LA

N

1B

O

P T

IO

N

IT

E

M

JG

17321914

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A -1

M A

T C

H

LI

N E

A B

SCALE: 1/8" = 1'-0" (A-101)

A1

ENLARGED FLOOR PLAN - 1B

PLAN

NORTH

1/8" = 1' - 0" 0 5' 10' 15' 30'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

FLOOR PLAN LEGEND

SCALE: 1/8" = 1'-0" (A-103)

A4

OPTION ITEM #2

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

DN

DN

DN

C3

A-201

A1

A-202

A1

A-201

C1

A-202

G

A

B

C

E

D

F

1 2 3 4 5 6 7 8 9

223'-10"

27'-11" 28'-0" 28'-0" 28'-0" 28'-0" 28'-0" 28'-0" 27'-11"

'-1

1"

'-0

'-0

'-0

'-0

'-1 1"

7'

-1 0"

OPPOSING

FORCES CONTROL

CELL

206B

OPPOSING

FORCES CONTROL

CELL

206A

INTEL CONTROL

CELL

205B

INTEL CONTROL

CELL

205A

JFACC / AVIATION

OPS CENTER

227B

JFACC / AVIATION

OPS CENTER

227A

BLUE / GREEN

FORCES CONTROL

CELL

226B

BLUE / GREEN

FORCES CONTROL

CELL

226A

HHQ RESPONSE

CELL

TECG INTEL

SECTION AND RED

CELL

225A

TECG INTEL

SECTION AND RED

CELL

225B

BREAK RM

PRINT RM

TECG - ADMIN

CELL AND

LOGISTICS

SECTION

TA - G9

EXPERIMENTATION

TA - TECHCON

208A

TA - TECHCON

208B

SIM TECH

CONTROL JLVC /

MCVP

TECG OFFICE /

CONF RM

SVTC CONF RM /

SIPR CAFE

GTR 2

GTR 2T (TRAINING

TELECOMM RM)

MECH RM

TRAINING

MATERIAL

STORAGE

TA - G6 PRIMARY

C4

A-301

C4

A-301

A1

A-301

A1

A-301

LOBBY 2

L2

A-105

A1

A-106

A1

ELEC CLOSET

TRAINING

MATERIAL

STORAGE

CONF RM

211A

OFFICE

211B

OFFICE

211C

OFFICE

211D

OFFICE

211E

OFFICE

211F

ELEV 2

E2

STAIR 2A

S2A

STORAGE

CTR 2

WOMEN

JAN

MEN

CORRIDOR 2D

C2D

CORRIDOR 2A

C2A

CORRIDOR 2B

C2B

CORRIDOR 2C

C2C

STAIR 2C

S2C

ELEC CLOSET

STAIR 2B

S2B

C1

A-301

C1

A-301

1. REFER TO SHEET A-502 FOR PARTITION TYPES.

2. REFET TO SHEET A-750 FOR DOWNSPOUT DETAILS.

3. REFER TO SHEET A-730 FOR CORNER GUARD, FIRE EXTINGUISHER

CABINETS, RAISED ACCESS FLOORING, AND FLOOR DRAIN DETAILS.

RAISED ACCESS FLOORING

SECURED AREA BOUNDARY

SYMBOL DESCRIPTION

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :5

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

A-104

JF

Y

P

R O

JE

C

T J

-8

O V

E R

A

LL

S E

C O

N D

F

LO

O R

P

LA

N

JG

17321915

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A -1

M A

T C

H

LI

N E

A B

SCALE: 1/16" = 1'-0" (A-201)

A1

OVERALL SECOND FLOOR PLAN

PLAN

NORTH

1/16" = 1' - 0" 0 5' 10' 20' 30' 60'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

OVERALL FLOOR PLAN LEGEND

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

3. REFER TO SHEET A-730 FOR CORNER GUARD, FIRE EXTINGUISHER

CABINETS, RAISED ACCESS FLOORING, AND FLOOR DRAIN DETAILS.

G

A

B

C

E

D

F

1 2 3 4 5 6

'-1

1"

'-0

'-0

'-0

'-0

'-1 1"

27'-11" 28'-0" 28'-0" 28'-0" 28'-0"

OPPOSING

FORCES CONTROL

CELL

206B

OPPOSING

FORCES CONTROL

CELL

206A

INTEL CONTROL

CELL

205B

INTEL CONTROL

CELL

205A

JFACC / AVIATION

OPS CENTER

227B

TA - G9

EXPERIMENTATION

207 TECG - ADMIN

CELL AND

LOGISTICS

SECTION

PRINT RM

ELEC CLOSET

TA - TECHCON

208A

TA - TECHCON

208B

SIM TECH

CONTROL JLVC /

MCVP

TRAINING

MATERIAL

STORAGE

CONF RM

211A

TECG OFFICE /

CONF RM

OFFICE

211B

OFFICE

211C

OFFICE

211D

OFFICE

211E

OFFICE

211F

SVTC CONF RM /

SIPR CAFE

GTR 2

GTR 2T (TRAINING

TELECOMM RM)

BREAK RM

CORRIDOR 2A

C2A

CORRIDOR 2B

C2B

CORRIDOR 2C

C2C

LOBBY 2

L2

ELEV 2

E2

STORAGE

CTR 2

MECH RM

227B205A

205B206A206B

208A

208B

211A

211B

211C

211D

211E

211F

215A

225B

207A 7' -0

1'-2"

3'-6" 5'-0"

1'-2" 3'-6"

5'-0" 14'-4"

1'-10"

3' -4

9'

-4

5' -0

6'-0" 12'-8"

4' -8

7'

-0

5' -0

3'

-6

3' -2

5' -0

3'

-6

3' -2

6'-0"

5' -0

9' -4

3'-6" 6'-4"

3'-6"

7' -0

2' -6

5'-0"

5' -0

3'

-6

3' -2

'-4

P6AS

P6S

P6S

P6AS

P6A

P6A

P6A

P6A P6 P6 P6

P6

P6A

P6A

P6AP6A

P6A

F3A

F3A

P6A

P6A F3A

F3A

P6A

P6A

P6A P6A

P6A

F3A F3A

P6A

F3A

P6A P6A

F3A

P6A

P6A

P6A

P6A

P6A P6A

P6A P6A

F3A

P6AS

P6AS

P6AS

P6AS

P6AS

F3A

P6A

5' -0

5'

-0

P6AM

P6A

P6A

P6S

P6S

P6AM

F6AM

P6AM

P6AM

P6A

P6A

P6A

P6A

P6A

P6A

P6A P6A

P6A

F2F3A

F2

F2

P6ASM

F6AM

P6ASM

P6ASM

P6AM

P6AM

P6ASM

P6ASM

P6ASM

P6ASM

C3AM

P6S

P6

P6S

P6S

P6A

C3AS

P6AM

P6AM

F6

P6A

P6A P6A

P6A P6A

F3A F3A F3A

F3A

STAIR 2B

S2B

P6AM

F3A

B3 B3B3 B3 B3 B3 B3 B3

3'-2" 3'-2"

B3

3'-2" 3'-2" 3'-2"

B3

B3

3'-2" 3'-2" 3'-2" 3'-2" 3'-2" 3'-2"

3' -2

3'

-2

3' -2

2' -0

B3 B3 B3

B3

B3

B3

2' -0

205 227

S E

E S

C H

E D

U

LE

S E

E S

C H

E D

U

LE

SEE SCHEDULE

S E

E S

C H

E D

U

LE

CG

CG

CG CG

CG CG

CG

CGCGCG

CG

CG CGCG

CG

CG

CG

CG CG CG

CGCG CG CG

CG CG

CG

CG CG

CG CG

CG

CG

CG

CG

CG

CG

CG

CG

CG

A-413

C1

A-415

A4

DSDSDS

DS

DS

DS DS DS

LVR-203

A4

A-311

A-504

A3

6'-8" 10'-0"

F6

F6

3' -2

WM

2' -6

3'

-2

6'-0"

5'-0"

PARTITION OR FURRED WALL

GRIDLINE

CONC WALL

CORNER GUARD

X

RECESSED ENTRY FLOOR MAT

SYMBOL DESCRIPTION

ROOMNAME

ROOM NAME AND NUMBER

101 DOOR NUMBER SYMBOL

A1

A-101

SECTION/ELEVATION

P1

A-101

A1 SIM

PARTITION TYPE

WINDOW SYMBOL

DOWNSPOUTDS

FLOOR DRAIN, SEE PLUMBINGFD

CG

A

FIRE EXTINGUISHER CABINETFEC

KNOX BOXKB

DETAIL REFERENCE

OPERABLE PARTITION TAG101

A.

S.U.II,AW

A H

M Y L E

S

M M I CH

I B A T A

LICENSED

No. 12367

ARCHITECT

PROFESSIONAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

P A

C

IF

IC

M

A K

A L A

P A

H

A W

A

II

AS NOTED

LIC. EXP 04/30/26

/1

/2

:1 :5

P

M

C U s e rs

\r lB a lin to n a

\D o c u m e n ts

\B L

D G

-J

-1

-A rb a lin to n a F

L

V N

.r v t

A-105

JF

Y

P

R O

JE

C

T J

-8

E N

LA

R

G E

D F

LO

O

R P

LA

N

2A

JG

17321916

JG / RLB RLB

3/10/2026

NATHANIEL PYRON, MILCON

PLANNER, DPPH

B A

TT

LE

S

TA

F F

T R

A

IN

IN

G

F A

C

IL

IT

Y

DKS/DMK

1696746

N62742-20-D-0001

M C

B C

A M

P B

LA

Z

, G U

A M

U .S

. N A

V S

U P

P A

C T

KYM

KYM

RYO

N A

V F

A C

P A

C

IF

IC

A -1

M A

T C

H

LI

N E

A B

SCALE: 1/8" = 1'-0" (A-104)

A1

ENLARGED FLOOR PLAN - 2A

PLAN

NORTH

1/8" = 1' - 0" 0 5' 10' 15' 30'

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

KEY PLAN

FLOOR PLAN LEGEND

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

3. REFER TO SHEET A-730 FOR CORNER GUARD, FIRE EXTINGUISHER

CABINETS, RAISED ACCESS FLOORING, AND FLOOR DRAIN DETAILS.

G

A

B

C

E

D

F

5 6 7 8 9

28'-0" 28'-0" 28'-0" 27'-11"

'-1

1"

'-0

'-0

'-0

'-0

'-1 1"

205A 227B

215A

MECH RM

CTR 2

STORAGE

ELEV 2

E2

STAIR 2A

S2A

TRAINING

MATERIAL

STORAGE

VESTIBULE 2

V2

WOMEN

MEN

JAN

TA - G6 PRIMARY

ELEC CLOSET

CORRIDOR 2D

C2D

HHQ RESPONSE

CELL

TECG INTEL

SECTION AND RED

CELL

225A

TECG INTEL

SECTION AND RED

CELL

225B

BREAK RM

JFACC / AVIATION

OPS CENTER

227B

JFACC / AVIATION

OPS CENTER

227A

BLUE / GREEN

FORCES CONTROL

CELL

226B

BLUE / GREEN

FORCES CONTROL

CELL

226A

219A

217A

218A

223A

226A226B227A

225B 225A

3' -6

5'

-0

3' -6

3'

-2

5' -0

3'

-6

3' -2

5'-0"

3' -6

5'-0"

4' -8

7'

-6

11'-2"

P6A

P6A

F3A

F3A

F6A

F3A

F3A

F3A

P6A

P6A

P6A

P6A P6A

P6AP6A