16_AF701 - FINISH PLAN -SEVENTH FLOOR.pdf

PDF 2 MB Posted

Attached to
Y1AZ--Design Build, Construct SICU and Renovate Operating Rooms
Solicitation number
36C10F22R0036
Issued by

View the file

Other files

File Type Posted
Award Notice 36C10F24C0002.pdf PDF
36C10F22R0036 0004.pdf PDF
36C10F22R0036 0003.pdf PDF
36C10F22R0036 0002.pdf PDF
36C10F22R0036 0001.pdf PDF
36C10F22R0036.pdf PDF
45_PL102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
40_PPD101 - SEVENTH FLOOR -PLUMBING DOMESTIC WATER DEMOLITION PLAN.pdf PDF
61_MHP100 - MECHANICAL DUCT and PIPING PLAN -ROOF LEVEL.pdf PDF
17_AF702 - FINISH PLAN -EIGHTH FLOOR.pdf PDF
07_ELEVATOR NARRATIVE.pdf PDF
52_MDH100 - MECHANICAL DUCT DEMOLITION PLAN -SEVENTH FLOOR.pdf PDF
100 percent RFP PLUMBING CALCS.pdf PDF
48_PJ101 - SEVENTH FLOOR -PLUMBING MEDICAL GAS PLAN.pdf PDF
55_MDP100 - MECHANICAL PIPING DEMOLTION PLAN -SEVENTH FLOOR.pdf PDF
44_PL101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT PLAN.pdf PDF
24_QH105 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 1.pdf PDF
04_FIRE PROTECTION.pdf PDF
OR-SICU 100 percent Digital Material Board.pdf PDF
28_QH109 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
27_QH108 - INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
84_EY301 - SEVENTH FLOOR ELECTRICAL LOW VOLTAGE PLAN.pdf PDF
4_GI102 - LIFE SAFETY PLAN -EIGHTH FLOOR.pdf PDF
86_EP401 - ELECTRICAL LIGHTNING PROTECTION PLAN.pdf PDF
21_QH102 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 2.pdf PDF
13_AE115 - DIMENSION PLAN -EIGHTH FLOOR.pdf PDF
90_EP504 - ELECTRICAL DETAILS.pdf PDF
88_EP502 - SCHEDULES AND DETAILS.pdf PDF
26_QH107 - EQUIPMENT PLAN -EIGHTH FLOOR -AREA 3 and INTERIOR EQUIPMENT ELEVATIONS.pdf PDF
39_PLD102 - EIGHTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
9_AE111 - REFERENCE PLAN -SEVENTH FLOOR.pdf PDF
12_AE114 - DIMENSION PLAN -SEVENTH FLOOR.pdf PDF
14_AE211 - REFLECTED CEILING PLAN -SEVENTH FLOOR.pdf PDF
01_Mold Report.pdf PDF
Floor 7 Inventory OKC VAMC.pdf PDF
71_M-704 - MECHANICAL CONTROLS.pdf PDF
30_FA001 - FIRE ALARM_MASS NOTIFICATION GENERAL NOTES.pdf PDF
56_MDP101 - MECHANICAL PIPING DEMOLTION PLAN -EIGHTH FLOOR.pdf PDF
02_ARCHITECTURAL.pdf PDF
1_GI000 - COVER SHEET.pdf PDF
50_P-600 - PLUMBING SCHEDULES.pdf PDF
82_EL201 - SEVENTH FLOOR ELECTRICAL LIGHTING PLAN.pdf PDF
66_M-502 - MECHANICAL DETAILS.pdf PDF
60_MH103 - MECHANICAL ZONING and CONTROLS PLAN -EIGHTH FLOOR.pdf PDF
06_ELECTRICAL NARRATIVE.pdf PDF
02_STRUCTURAL NARRATIVE.pdf PDF
20_QH101 - EQUIPMENT PLAN -SEVENTH FLOOR -AREA 1.pdf PDF
38_PLD101 - SEVENTH FLOOR -PLUMBING WASTE AND VENT DEMOLITION PLAN.pdf PDF
Floor 8 Inventory OKC VAMC.pdf PDF
63_MP101 - MECHANICAL HVAC PIPING PLAN -EIGHTH FLOOR.pdf PDF
Show 40 more

Latest 50 of 122 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FD

FD

FD

FD

FD

FD

FD

WSF1 (WELDED SHEET FLOORING)

WSF2 (WELDED SHEET FLOORING)

CPT1 (CARPET TILE)

LVT2 (LUXURY VINYL TILE)

RF1 (RUBBER FLOOR TILE)

SD1 (STATIC DISSAPATIVE TILE)

PT1 (PORCELAIN TILE MOSAIC)

FLOOR FINISH PATTERN LEGEND

RES1 (RESINOUS FLOORING)

RES2 (RESINOUS FLOORING)

LVT1 (LUXURY VINYL TILE)

INSTALLATION AT 45 DEGREE ANGLE

LVT1 (LUXURY VINYL TILE)

INSTALLATION AT 90 DEGREE ANGLE

RF2 (RUBBER STAIR TREAD)

1. ALL WALLS TO BE PAINTED P2, UNO.

2. ALL UPPER CABINETS TO HAVE 30° SLOPED TOP WHERE NOT RECEIVED BY CEILING ABOVE.

3. ALL RUBBER BASE TO BE RB1 UNO.

4. ALL STAIR LANDINGS TO RECEIVE RUBBER FLOOR TILE (RF1), UNO. ALL STAIR TREADS TO BE

(RF2), UNO.

5. ALL OUTSIDE CORNERS TO RECIEVE CORNER GUARDS. ALL GUARDS AT 90 DEGREE CORNERS

TO BE CG1 UNO, ALL GUARDS AT 135 DEGREE CORNERS TO BE CG2 UNO.

6. ELEVATOR WALL, CEILING AND BASE FINISHES TO BE CHOSEN FROM MANUFACTURERS LINE OF

STANDARD FINISHES.

7. REFEREENCE ROLLER SHADE (R1 & R2) FOR WINDOW TREATMENT BASIS OF DESIGN.

8. ALL OUTSIDE EDGES OF PORCELAIN WALL TILE TO RECEIVE METAL TRANSITION STRIP (TR1).

9. FLOOR TRANSITIONS BETWEEN PORCELAIN TILE AND OTHER FLOORING TYPES TO RECEICVE

METAL TRANSITION STRIP (TR2). CONTRACTOR TO VERIFY SIZE OF TRANSITION STRIP

REQUIRED TO PROVIDE ADA COMPLIANT TRANSITION IN FLOORING HEIGHT.

10. UNEVEN FLOOR TRANSITIONS BETWEEN RESILIENT FLOORING TYPES TO RECEIVE BUBBER

TRANSITION STRIP (TR3). CONTRACTOR TO VERIFY SIZE OF TRANSITION STRIP REQUIRED TO

PROVIDE ADA COMPLIANT TRANSITION IN FLOORING HEIGHT.

11. ASBESTOS OR ASBESTOS CONTAINING PRODUCTS ARE NOT ALLOWED IN ANY ASPECT OF THIS

CONSTRUCTION.

12. COORDINATE ALL DISCIPLINES AND ALL ASPECTS OF WORK. CONFLICTS AND DISCREPENCIES

SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY.

13. ALL CONCRETE SURFACES WHICH RECEIVE A SPECIAL FINISH, FLOOR COVERING, COATINGS, HARDENERS, ETC. SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE SPECIFIC FINISH

MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. PRIOR TO APPLICATION OF A SPECIAL FINISH, A WRITTEN ACCEPTANCE OF THE SURFACE SHALL BE SUBMITTED TO THE ARCHITECT BY

THE GENERAL CONTRACTOR.

14. REMOVE ALL FLOOR FINISHES AND ADHESIVES AND STRIP FLOOR DOWN TO EXISTING

CONCRETE. LEVEL AND PREP FLOOR FOR INSTALLATION OF NEW FLOOR FINISHES AS NOTED.

15. DESIGN BUILD TEAM AND A/E OF RECORD MUST FOLLOW ALL CURRENT VA NATIONAL TIL

STANDARDS, INCLUDING VA NATIONAL CAD STANDARDS, THROUGHOUT DESIGN AND

CONSTRUCTION

GENERAL FINISH NOTES

1 2 3 4 5 6 7 8 9 10 11

11a

C1

D

E

F

G

H

I

J

K

9A

G2

EXISTING

CLEAN CORE

EXIST.

TELECOM

CHECK-IN

CHECK-OUT

1'-6" TYP.

1'-6" TYP.

1' -6

T

Y P

STORAGE

STORAGE

SCRUB

SCRUB

GAS CYLINDERS

GAS CYLINDERS

IMAGE EQUIP

COMPONENT

ROOM

IMAGE EQUIP

COMPONENT

ROOM

CONTROL ROOM

723B

CONTROL ROOM

723B

HAC

HAC

NEURO EQUIP

NEURO EQUIP

NEUROSURGERY

OR 9

728A

NEUROSURGERY

OR 9

728A

HYBRID OR 10

723A

HYBRID OR 10

723A

SCRUB

SCRUB

HYBRID STORAGE

723C

HYBRID STORAGE

723C

CARDIAC OR 3

720A

CARDIAC OR 3

720A

STAIR 10

STAIR 10

STORAGE

STORAGE

GAS STORAGE

GAS STORAGE

TOILET

TOILET

CORRIDOR

COR-7-10

CORRIDOR

COR-7-10

CORRIDOR

COR-7-12

CORRIDOR

COR-7-12

CORRIDOR

COR-7-9

CORRIDOR

COR-7-9

CORRIDOR

COR-7-8

CORRIDOR

COR-7-8

BIOMED

COMMUNICATION

BIOMED

COMMUNICATION

CORRIDOR

COR-7-6

CORRIDOR

COR-7-6

CORRIDOR

COR-7-3

CORRIDOR

COR-7-3

POST-OP AREA

POST-OP AREA

MEDICATION

MEDICATION

TOILET

TOILET

STORAGE

STORAGE

CLEAN SUPPLY

CLEAN SUPPLY

EQUIPMENT

STORAGE

720C

EQUIPMENT

STORAGE

720C

IT CLOSET

IT CLOSET

ELEVATOR

P-12

ELEVATOR

P-12

EXIST. ELEC

CLOSET

7F-116a

EXIST. ELEC

CLOSET

7F-116a

EXIST. ELEC

CLOSET

7F-116

EXIST. ELEC

CLOSET

7F-116

SOILED UTILITY

SOILED UTILITY

MEDICATION

MEDICATION

STORAGE

STORAGE

RECOVERY

RECOVERY

ISOLATION BAY

ISOLATION BAY

CONSULT

CONSULT

OR COUNTER

702A

OR COUNTER

702A

ELEVATOR LOBBY

COR-7-1

ELEVATOR LOBBY

COR-7-1

ELEVATOR

P-8

ELEVATOR

P-8

ELEVATOR

P-7

ELEVATOR

P-7

ELEVATOR

P-9

ELEVATOR

P-9

ELEVATOR

P-10

ELEVATOR

P-10 STAIR 8

STAIR 8

TOILET

701C

TOILET

701C

TOILET

701B

TOILET

701B

CORRIDOR

COR-7-2

CORRIDOR

COR-7-2

SURGICAL

WAITING

701A

SURGICAL

WAITING

701A

ALCOVE

ALC-7-1

ALCOVE

ALC-7-1

PUMP ROOM &

ABG

720B

PUMP ROOM &

ABG

720B

SOILED UTILITY

SOILED UTILITY

CLEAN SUPPLY

CLEAN SUPPLY

STORAGE

STORAGE

TOILET

TOILET

ANTE ROOM

ANTE ROOM

CORRIDOR

COR-7-4

CORRIDOR

COR-7-4

CORRIDOR

COR-7-5

CORRIDOR

COR-7-5

PATIENT BAY

704B

PATIENT BAY

704B

PATIENT BAY

704A

PATIENT BAY

704A

PATIENT BAY

704C

PATIENT BAY

704C

PATIENT BAY

704D

PATIENT BAY

704D

PATIENT BAY

704E

PATIENT BAY

704E

PATIENT BAY

704F

PATIENT BAY

704F

PATIENT BAY

704G

PATIENT BAY

704G

PATIENT BAY

704H

PATIENT BAY

704H

PATIENT BAY

704J

PATIENT BAY

704J

RECOVERY BAY

711L

RECOVERY BAY

711L

RECOVERY BAY

711K

RECOVERY BAY

711K

RECOVERY BAY

711J

RECOVERY BAY

711J

RECOVERY BAY

711H

RECOVERY BAY

711H

RECOVERY BAY

711B

RECOVERY BAY

711B

RECOVERY BAY

711C

RECOVERY BAY

711C

RECOVERY BAY

711D

RECOVERY BAY

711D

RECOVERY BAY

711E

RECOVERY BAY

711E

RECOVERY BAY

711F

RECOVERY BAY

711F

RECOVERY BAY

711G

RECOVERY BAY

711G

REFRESHMENT

CENTER

701D

REFRESHMENT

CENTER

701D

HAC

HAC

CORRIDOR

COR-7-7

CORRIDOR

COR-7-7

DOC. STORAGE

702B

DOC. STORAGE

702B

RECOVERY BAY

711A

RECOVERY BAY

711A

1' -0

T

Y P

1'-0" TYP. 1'-0" TYP.

1' -0

T

Y P

1'

-0

T Y

P

1'-0" TYP.

1'-0" TYP.

1' -0

T

Y P

1'-0" TYP.

1' -0

T

Y P

1'

-0

T Y

P

1' -0

T

Y P

1'-0" TYP.

4' -0

'-1

1/ 2"

4' -0

1' -6

T

Y P

4' -3

'-0

/4

4' -3

2'

-0

8' -9

1'

-2

10'-9" 10'-9"

WITH FACE OF WALL

ALIGN EDGE

1'-0" TYP.

1' -0

T

Y P

6'-0" 6'-0"

6' -0

6'

-0

7'-0" 7'-0"

7' -0

7'

-6

6' -0

6'

-0

/2

6'-0" 7'-0"

'-9

'-1

8' -8

'-9

'-9

'-9

'-4

4'

-1

20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 20'-9" 8'-6" 12'-3" 2'-6" 10'-9"

200'-0"

'-0

'-9

'-9

SCRUB

7F120

GENERAL

O.R. #2

7F122

GENERAL

O.R. #1

7F118

SUB

STERILE

7F113b

SHAFT

SUB

STERILE

7F113a

H.A.C.

7F114CARDIAC

O.R. #4

7F128

CLEAN

UTILITY

7F129

X-RAY

STORAGE

7F130

H.A.C.

7F131 SCRUB

7F132

SUB

STERILE

7F133c

N

RECOVERY &

SURGICAL WAITING

7TH FLOOR KEY PLAN

POST- OP

OPERATING ROOMS

HANDRAIL / WALL GUARD

FINISH: HR1 / WG1

WALL ACCESSORY LEGEND

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

Building Number

Drawing Number

CONSULTANTS:

Drawing #

VA Office Of Construction & Facilities Management Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

OK ARCH REG. NO. CA02295, EXP. 06/30/2023

OK ENGR REG. NO. CA7127, EXP. 06/30/2023

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

HEALTHCARE PLANNER

OCULUS INC.

1 S. MEMORIAL DR., SUITE 1500

ST. LOUIS, MO 63102

(314) 367-6100

SPUR PROJECT NUMBER: 1791.08

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

SEE FRONT COVER SHEET

FOR APPROVAL SIGNATURE

VERTICAL TRANSPORTATION

ENVIRONMENTAL HYGIENIST

TEC-AN, INC.

2517 S. PURDUE AVE.

OKLAHOMA CITY, OK 73128

(405) 681-7076

LERCH BATES

2001 BRYAN ST., SUITE 1930

DALLAS, TX 75201

(972) 294-5221

/2

/2

:1 :2

P

M

AF701

FINISH PLAN - SEVENTH FLOOR

SP

16 OF 92JNK

100% RFP DOCUMENTS

CONSTRUCT SURGICAL INTENSIVE

CARE UNIT & RENOVATE

OPERATING ROOMS

08/02/2021

635-436

OKLAHOMA CITY VA HEALTHCARE SYSTEM

921 NE 13TH ST, OKLAHOMA CITY, OK 73104

N

1/8" = 1'-0"

SEVENTH FLOOR FINISH FLOOR PLAN

No. REVISION DESCRIPTION DATE

File details come from the government source that posted it. Updated .